TPro ver 1.0 Temperature Probe User Interface for Windows 95,98,NT Release Notes FR 07/14/00 18:15 The version of TPro released with the date and time above has eliminated the following known bugs: - Year now correctly displayed - Port initialization works correctly w/o going to setup menu At this time, there are no known run-time bugs. There have been some problems running TPro on certain computers. This is due to some differences in .DLL files distributed with various versions of Windows, and has been successfully fixed by installing and then uninstalling the development environment (MS Visual C++). You may contact me to borrow the CD. The following notes may be helpful: - Data is written as it is received and is not buffered; Thus, the data should be safe in the event of a software or hardware crash. - Click the Logging Status button to begin data logging. The Button text will change to indicate that the software is logging data, and there may be messages visible briefly in the Status bar when data is being written. Data is always appended to the Logfile specified in the Setup box. Unwanted data files must be manually deleted. - A header is placed before the first record, each time TPro is executed. This serves to indicate the beginning of a data logging session. The header consists of a short message and a line indicating the record format. Note that time is gmt and there is a julian day field for your convenience. - The file tpro.dat contains only the com and calibration setting for TPro. If this file is lost or deleted, the some of the information will have to be input again via the setup menu. TIP: you may wish to save this file under a different name to use for different probe combinations. - The Save & Exit Button saves only the TPro setup data (to tpro.dat) and has no effect on incoming data. The logged data file is automatically saved during logging. - If there is continuous Invalid Data messages and the Temp values look like random characters, try toggling the Echo setting in the setup menu and verify the Com port baud rate are correct. - The A/D channels will not in general need to be changed from their defaults. Changing this setting will not change the logged data records, but only the display of data to the screen. - The Probe calibration settings apply only to the data displayed on the screen. The logged data consists of ASCII decimal integer raw count values, exactly as they are received from the probe microprocessor, with a date and time prepended. Your questions, suggestions and other feedback on this software are welcome. --------------------- Kent Headley MBARI (831) 775-1822 headley@mbari.org