Notes: P/S Design Review HRH 26 Oct 2020 10:00 - 12:00 Signal B_12V_ISO_BATT needs to be switched w/ latching relay It could be on the same relay as the Apollo other set of contacts Benthos Acoustic Modem needs to be added Look at the current power board for architecture ( also see page 8 ) Sheet 4: replace U136 HiSideSw w a latching relay or a P-FET or an OptoCoupler w/ enough output current Sheet 6: put Benthos Acoustic Modem ACM+ and ACM- on a separate connector Sheet 7: Reed switch goes away Add a scaled digital input from J32 pin 2/3 to XLP that tells XLP the state of the pressure switch Sheet 8: Remove the one-shots Drive the FETs directly from GPIO Use K3 to turn on/off pwr to the Benthos Acoustic Modem Wire U124 output directly to J27 Avtrak 6 Sheet 9: Eliminate U3 U2 is not beefy enough; need 12-15 Amps ( ISO rating is higher that we want to run the switch ) Use a single switch, not two in parallel Worse case: just a fuse, or a relay Possibilities: VN5016 BTS6133 VN920 BTS441 ( HRH suggestion ) Sheet 12: J30 B_RDF_STBY_BATT_6V needs to be wired in parallel Identify what each battery pack us used for