On Aug 20, 2019, at 9:34 AM, Josh Tetarenko <tetarenko.josh@gmail.com> wrote:

Hey DJ,

Let me know if this helps. Setup procedure is in the second half of the PDF.

Thanks,
Josh

<Circuit Description and Setup Procedure GFIV1.2.pdf>


On Aug 19, 2019, at 9:05 AM, DJ Osborne <djo@mbari.org> wrote:

Hey Josh,
Fantastic.  No panic.  Anytime this week would be great.
Glad your doing well, hope business is doing good.
dj
 
From: Josh Tetarenko [mailto:tetarenko.josh@gmail.com] 
Sent: Monday, August 19, 2019 8:15 AM
To: DJ Osborne
Subject: Re: DTEC GFI board
 
Hey DJ,
 
I think I can find what you are looking for, but I am offshore until tomorrow. Ill try to get you the setup procedure by then.
 
Thanks,
Josh


On Aug 19, 2019, at 8:50 AM, DJ Osborne <djo@mbari.org> wrote:
 
Hi Josh,
Hope things are going well up there.
We are doing well here, we are busy doing a 40 to 50 hp upgrade for Ventana this month – among other upgrades.  One issue we have been chasing is some behaviors of our ground fault board.  We think most of the issues are software related but we are making an effort to make sure we understand all the details of the ground fault board hardware as well.
 
We purchase our GFI boards from you and have several of them.  When we purchased the last one a couple years ago you had a readable schematic that was very helpful since our copies were very difficult/impossible to read.  I am writing to ask if you can look for any set up documentation for this board.  
 
Here is an excerpt from the old DTEC Ventana control system manual…
 
9.2 Water Alarm and Ground Fault Board GFIWATER:
               The water alarm section of the board provides isolation and amplification of the water alarm sensors.  Each transistor buffer has two wires attached to it that are placed a the bottom of the housing to be monitored.  When these two wires conduct through the intrusive water the transistor is turned on and produces a digital signal.  This signal is isolated from Logic or other power supplies and so is routed through an opto-isolator which provides a logic level output to be wired into the GESIN board.
               The ground fault section of the board is similar the system ground fault board but is more suited to lower voltage circuits.  In this system it is used to monitor the isolated analog circuits that cannot be monitored by the system ground fault board (because they are isolated).  There is about 25VDC placed onto the sense wire of each circuit through a high impedance source.  This voltage is with respect to chassis ground.  When this sensed voltage is pulled down by a Ground Fault it reduces the voltage to the analog isolator.  The analog isolator is inverting which means that the lower the sense voltage the higher the output from the analog isolator.  5.00VDC output corresponds to a Short on the Ground Fault side and 0.00 VDC on the output corresponds to an open or infinite Ground Fault impedance.  See the section on the GFIWATER board for more information.
 
9.3 Ground Fault Board GFIV1.2:
               See Appendix Ground fault board description and setup procedure.
 
Can you please have a look around and see if you can locate a copy of this Ground Fault board set up Procedure??
 
From our initial analysis of the board hardware the tuning of the board in the particular system it is installed into appears to be quite sensitive/critical.
Although your section 9.3 refers to an appendix on how to set up the board it turns out that no such appendix exists in our manual.  We are hoping you have some documentation that would help us out.
 
Thanks so much,
dj