Connect comms tether Connect hiCurrent tether to Insp Eng battery Determine IP addresss of hiCurrent supply Power up the power supplies Open two Cygwin windows telnet into the hiCurrent supply eg: telnet 134.89.32.201 10003 turn on power supply output outp:state on set current to 1.5 Amps outp:curr 1.5 outp:curr? ( reads back 1.5 ) outp:volt? ( reads back 32.5 ) --> Max current into any one pack 1.5 Amps telnet into Insp Eng battery eg: telnet 134.89.32.121 10003 turn off the watchdog battery>WDOFF check battery status @99RQ set battery to charge @99AC check if charging packs @99RQ in power supply window meas:curr? if OK, double the current outp:curr 3 check battery packs @99RQ if OK, double the current outp:curr 6 repeat until charging at 45 Amps battery status #00:0583,0000,31488,1683,026,00C0 | | | | | | | |_ flags | | | | | | |__ number of cycles | | | | | |___capacity in milliAmp hours | | | | |___battery milliVolts | | | |____battery current ( + charge, - dischg ) | | |____battery serial number | |_____battery ID number in sphere |____# off, * on, . shutdown ( new batts only ) battery commands @99RQ status @99AF off @99AD discharge @99AC charge @99AH reset gas gauge @45PF turn off pack 45 flags