Rev: 102
#==========================================================
#File		:sensor_commands.txt
#Details	:this file contains the fixed bootload for the
#		:CMV12000 Ver2 sensor	
#Originator	:Fergal Brennan
#==========================================================
#File history
#
#01-Mar-2015	Formatting file for release to software
#02-Dec-2016	Modifying ADC slope values to improve sensor
#		response and dynamic range. See ECO-0592		
#Note: This will not work with a Rev 1 sensor						
#==========================================================
#Command format	:set cmv [register][value]
#==========================================================

#Set sensor ADC slope to 10 bit mode
#V102 changes this value from 1023 to 900
set cmv 116 900

#Set sensor digital gain to 4/4
set cmv 117 4

#Set blacksun correct to min value - adjustable 
set cmv 102 8192

#FB FPN change 21-11-2014 was 9937
set cmv 107 9942

#Internal VREF generator - adjustable
set cmv 108 12382

#Vramp1 and Vramp2 registers - adjustable
set cmv 109 12255

set cmv 110 12368
set cmv 82 1054

#Registers 83,85 and 86 are varied according to the image mode. They take
#on different values for normal vrs binning vrs subsampling
#set cmv 83 5893
#set cmv 85 1031
#set cmv 86 1031

set cmv 69 2
set cmv 81 3
set cmv 84 128
set cmv 97 0
set cmv 99 34952

#V102 Change register 100's value from 0 to 3
set cmv 100 3

set cmv 101 0
set cmv 103 4032
set cmv 104 64
set cmv 105 8256
set cmv 111 34952
set cmv 112 5

#V102 Add register 113 with value of 789
set cmv 113 789

set cmv 114 80
set cmv 118 1
set cmv 119 0
set cmv 120 9
set cmv 121 1
set cmv 122 32
set cmv 123 0
set cmv 124 15
set cmv 125 2
set cmv 126 770