Note that the after loading a new modem version, all the sregisters will
be reset to the factory defaults.  If using the datalogger make sure the
command to clear the buffer is used before writing any data to the
buffer.


Instructions for loading Modem code.

1. Connect the Modem to Com port of your PC.
NOTE:SHUT DOWN ANY OTHER APPLICATIONS THAT ARE USING THE SAME COMPORT.

2. Run the DOS batch file LOADCODE <comport #>.

3. The batch file will start counting down from 20.

4. Turn the modem on before the count reaches 0, if the modem was already on
cycle power.

5. If the load was sucessful, the message "Modem received end string and 
terminated" should be displayed.

6. After loading a new version the frequency band may need to be reset.
The frequency band in use is displayed in the start up message.
Use the following commands to set the correct frequency band:

To set to LF band    ATS24*38<enter>
To set to MF band    ATS24*64<eneter>
To set to HF band    ATS24*9C<enter>

Use the AT&W command to store changes and then cycle power