reset Resetting... ---------------------------------------------------------------- Persistor CF21M SN 02066 PicoDOS V2.28r3 PBM V2.27 (C) 1998-2003 Persistor Instruments Inc. - www.persistor.com ---------------------------------------------------------------- The clock needs setting if it's not July 15, 1970! C:\>dir Volume in drive C is NONAME Volume Serial Number is 3CDE-5AB2 Directory of C:\ 0 file(s) 0 bytes 0 dir(s) 511,934,464 bytes free C:\>G boot app Next: => A - Program at E40000 PBM>reset Huh? PBM>res Resetting... deploy.dat does not exist. Continuing with deployment with default schedule. This can be modified by hitting Ctrl-X below and entering menu Hit Ctrl-X within 3 seconds to enter set-up 3..2.. Enter M to Enter Main Menu 1) Set Date and Time 2) File Actions 3) Set Deploy Parameters 4) Calibrate Accelerometers 5) Verify and Deploy 6) Data Offload 7) Exit to PicoDos 8) Sleep Enter Selection: ? 1 Current date and time: Wed Jul 15 02:15:22 1970 Reset date and time? [N] ? y Enter Date: [07/15/1970] ? 04/21/022004 Enter Time: [02:15:24] ? 20:29:00 Current date and time: Wed Apr 21 20:29:00 2004 Current date and time: Wed Apr 21 20:29:01 2004 Current date and time: Wed Apr 21 20:29:03 2004 Current date and time: Wed Apr 21 20:29:04 2004 Current date and time: Wed Apr 21 20:29:05 2004 Is time Correct? [Y] ? 1) Set Date and Time 2) File Actions 3) Set Deploy Parameters 4) Calibrate Accelerometers 5) Verify and Deploy 6) Data Offload 7) Exit to PicoDos 8) Sleep Enter Selection: ? 4 Calibrate Accelerometers selected Position axis 1 to positive one g (point upwards) Hit space bar when positioned TCR1 Clock = 160000 Hz positive g on time = 8029 counts Position axis 1 to negative one g (point downwards) Hit space bar when positioned negative g on time = 4783 counts period length = 14189 counts Calibration of axis 1 complete bias = 8.74245 offset = -3.94701 Position axis 2 to positive one g (point upwards) Hit space bar when positioned TCR1 Clock = 160000 Hz positive g on time = 6962 counts Position axis 2 to negative one g (point downwards) Hit space bar when positioned negative g on time = 7984 counts period length = 14980 counts Calibration of axis 2 complete bias = -29.3151 offset = 14.6243 Position axis 3 to positive one g (point upwards) Hit space bar when positioned TCR1 Clock = 160000 Hz positive g on time = 5464 counts Position axis 3 to negative one g (point downwards) Hit space bar when positioned negative g on time = 8710 counts period length = 14185 counts Calibration of axis 3 complete bias = -8.73999 offset = 4.36661 1) Set Date and Time 2) File Actions 3) Set Deploy Parameters 4) Calibrate Accelerometers 5) Verify and Deploy 6) Data Offload 7) Exit to PicoDos 8) Sleep Enter Selection: ? 3 Set Deploy Parameters selected <--------------------Sample Period-------------------> ___________________ _____ | | | | | | | | | __| |_________________________________| <--Sample Duration--> Enter sample period (seconds): [3600] ? Enter sample duration (seconds): [600] ? 900 Enter measurement frequency (Hz): [10] ? Enter date and time to take first measurement Enter Date: [04/21/2004] ? Enter Time: [21:30:22] ? 22:00:00 Enter date and time to take final measurement Enter Date: [04/21/2005] ? Enter Time: [22:00:00] ? Sample Period = 3600 seconds Sample Duration = 900 seconds Measurement Frequency = 10 Hz The first measurements will be made at Wed Apr 21 22:00:00 2004 The last measurements will be made at Thu Apr 21 22:00:00 2005 Is this correct? [Y] ? n <--------------------Sample Period-------------------> ___________________ _____ | | | | | | | | | __| |_________________________________| <--Sample Duration--> Enter sample period (seconds): [3600] ? Enter sample duration (seconds): [900] ? Enter measurement frequency (Hz): [10] ? Enter date and time to take first measurement Enter Date: [04/21/2004] ? Enter Time: [21:30:46] ? 21:00:00 Enter date and time to take final measurement Enter Date: [04/21/2005] ? Enter Time: [21:00:00] ? Sample Period = 3600 seconds Sample Duration = 900 seconds Measurement Frequency = 10 Hz The first measurements will be made at Wed Apr 21 21:00:00 2004 The last measurements will be made at Thu Apr 21 21:00:00 2005 Is this correct? [Y] ? 1) Set Date and Time 2) File Actions 3) Set Deploy Parameters 4) Calibrate Accelerometers 5) Verify and Deploy 6) Data Offload 7) Exit to PicoDos 8) Sleep Enter Selection: ? 5 Verify and Deploy selected using 51ms Timer Actual Measurement Frequency = 9.803922 Hz Actual Sample Duration = 904.127991 Seconds Memory Requirements per Sample = 53248 bytes Is this correct? [Y] ? Storing setup in deploy.dat Sleeping until Wed Apr 21 21:00:00 2004