To print this text file, a 10-point/12-pitch fixed font (e.g. Courier) is best ============================================================================== BULLETIN FSB-087 - TRANSECT CFG/ADCP HARDWARE CONFLICT IN ACQUIRE MENU DATE/REV: 20JUN95 / 0 (previously FSB95-7) ============================================================================== ABSTRACT: An error in the TRANSECT program may cause an Acquire Menu warning message about a conflict between the CFG file and ADCP hardware information. INSTRUMENT/PROGRAM AFFECTED: All ADCPs using Broadband TRANSECT (v2.72 or earlier) or Narrowband TRANSECT (v1.82 or earlier). DESCRIPTION: On some occasions, TRANSECT displays a message in the Acquire Menu that reads, "WARNING: CFG hardware information is different from ADCP." Normally, this message indicates that the hardware information stored in the configuration (.CFG) file does not match the hardware information stored in the ADCP's firmware. The hardware conflict/s are shown in TRANSECT's "ADCP CONFIG." window in the Acquire Menu. This warning message typically occurs (1) When a conflict truly exists, (2) When you use TRANSECT for the first time on a new or borrowed system, (3) After installing an upgraded firmware chip, or (4) When you use (e.g., borrow) a CFG file that was created on another ADCP. SOLUTION/ACTION: Description items (2), (3), and (4), above, occur because the TRANSECT program does not read and write the hardware information in the proper sequence. You can easily correct this problem or determine if a con- flict really exists by taking the following actions. 1. Start TRANSECT as you normally would. 2. If necessary, load the configuration (.CFG) file that causes the warning message to appear. 3. Go to the Acquire Menu to verify the warning occurs. 4. Exit the Acquire Menu and go to the Communication Menu. 5. Use the Verify Communications "button" to establish communications with the ADCP. We will assume this is successful. 6. When you exit the Communication Menu, make sure you select the SAVE op- tion. This will cause the ADCP to write its correct settings to the currently-loaded CFG file. 7. Go to the Acquire Menu again and verify the warning does NOT occur. 8. If the warning continues to appear, contact RDI. ==============================================================================