Awake Scanner Main Menu (Scan10.c Jun 18 2001 08:12:28) 1 -- Test Functions 2 -- Setup 3 -- Deploy 5 -- Sleep 9 -- Reset to PicoDOS Enter Selection: Data period = 60 sec X scan length = 10 cm Y scan length = 20 cm Camera start depth = 0 m Camera on time = 45 min Stir speed = 9 rpm Grab turns = 220 Burnwire time = 300 sec Optode time = 7 min Depth cal = 1.000000 Depth zero = 0.000000 Current RTC Clock Time: Mon Jun 18 09:46:09 2001 Start time = Mon Jun 18 10:15:00 2001 End time = Mon Jun 18 14:15:00 2001 Deploy function...do you want to continue [N] ? y Disconnect comm cable and deploy...