1.0 02/06/2008 Functionality: - Implements "MBARI Load Controller Command Set and Communications Protocol" version 3.2 - Reports steady-state overcurrent condition but does not trip off load - Does not perform checksums on 485 transactions - Does not implement startup current threshold checking - Does not implement sleep or "address ignore" jumpers - Fault Current (FC) command returns only the voltage - not the current - on a given channel - Pin 12 toggles with overcurrent checking on slave Known Bugs: - Load occasionaly powers on when slave is off due to floating pin. Timing Notes: - Slave can require approx 275 ms to boot. Typical is 150 ms. - Any commands requiring current calculations (e.g. "SO", "SS") require 3 ms for the slave to do the math.