01/08/2008 - EX 0.0 - Includes basic 485 command xmit/response and basic SPI bus communications. - Includes voltage and current readings on iso/non-iso cicuits - No ground fault detection functionality is included - The following commands are implemented: Control Commands: L C Read Status Commands: ?V ?v ?I ?i ?g ?O ?o ?T ?C ?S Set Threshold Commands: O o T S Related Documents: - SCH:1001998 Rev 0 (should be 1) November 15, 2007 Circuit Modifications Include: 1.) R16 from 100k to 10k 2.) U11 pin 11 has 100k pull down 3.) U7 pin 11 has 100k pull up 4.) U7 pin 6 (signal "Load Current") lifted and shorted to U7 pin 7 5.) J3 pin 2 connected to 5V com iso 6.) LS1 pin 18 trace cut and moved to LS1 pin 16. 7.) LS1 pin 15 trace cut and moved to LS1 pin 13. - Load Controller Interface Specification v2.3