3 1 - ADVANCE CAMERA ONCE 2 - CYCLE STROBES ONCE 3 - CYCLE DIGITAL CAMERA 4 - TURN ON DIGITAL CAMERA 5 - TURN OFF DIGITAL CAMERA 6 - EXIT ENTER SELECTION 2 CONTROL BAT VOLTS: 9.2 MAIN BAT VOLTS: 29 RIGHT STROBE HV: 382 LEFT STROBE HV: 382 AFTER FLASH... RIGHT STROBE HV: 32 LEFT STROBE HV: 38 1 - ADVANCE CAMERA ONCE 2 - CYCLE STROBES ONCE 3 - CYCLE DIGITAL CAMERA 4 - TURN ON DIGITAL CAMERA 5 - TURN OFF DIGITAL CAMERA 6 - EXIT ENTER SELECTION 2 CONTROL BAT VOLTS: 9.2 MAIN BAT VOLTS: 29 RIGHT STROBE HV: 382 LEFT STROBE HV: 382 AFTER FLASH... RIGHT STROBE HV: 32 LEFT STROBE HV: 40 1 - ADVANCE CAMERA ONCE 2 - CYCLE STROBES ONCE 3 - CYCLE DIGITAL CAMERA 4 - TURN ON DIGITAL CAMERA 5 - TURN OFF DIGITAL CAMERA 6 - EXIT ENTER SELECTION 3 1 - ADVANCE CAMERA ONCE 2 - CYCLE STROBES ONCE 3 - CYCLE DIGITAL CAMERA 4 - TURN ON DIGITAL CAMERA 5 - TURN OFF DIGITAL CAMERA 6 - EXIT ENTER SELECTION 5 * 1 - ADVANCE CAMERA ONCE 2 - CYCLE STROBES ONCE 3 - CYCLE DIGITAL CAMERA 4 - TURN ON DIGITAL CAMERA 5 - TURN OFF DIGITAL CAMERA 6 - EXIT ENTER SELECTION 6 LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 4 ENTER DEPLOYMENT DELAY TIME IN HOURS: 0 MAIN LOOP TIME: 60 MIN R-STROBE CHARGE TIME: 45 SEC L-STROBE CHARGE TIME: 45 SEC P-LINE ACTIVE TIME: 200 mSEC THE TIME IS: 15:27:35 on 5/14/10 CAMERA WILL START IN: 0 HOURS REMOVE COMM. CABLE AND DEPLOY BREAK AT LINE 5010 OK >RUN LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 1 THE YEAR IS (0 TO 99) 10 THE MONTH IS (1 TO 12) 05 THE DAY IS (1 TO 31) 14 THE HOUR IS (0 TO 23) 15 THE MINUTE IS (0 TO 59) 29 THE SECOND IS (0 TO 59) 00 THE TIME IS: 15:29:0 on 5/14/10 HIT RETURN TO CONTINUE LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 2 MAIN DELAY TIME IN MIN 5 RIGHT STROBE CHARGE TIME IN SEC 45 LEFT STROBE CHARGE TIME IN SEC 45 P-LINE TIME IN mSEC 200 MAIN TIME = 5 MIN R-STROBE = 45 SEC L-STROBE = 45 SEC PLINE = 200 mSEC HIT RETURN TO CONTINUE LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 4 ENTER DEPLOYMENT DELAY TIME IN HOURS: 0 MAIN LOOP TIME: 5 MIN R-STROBE CHARGE TIME: 45 SEC L-STROBE CHARGE TIME: 45 SEC P-LINE ACTIVE TIME: 200 mSEC THE TIME IS: 15:29:17 on 5/14/10 CAMERA WILL START IN: 0 HOURS REMOVE COMM. CABLE AND DEPLOY FIRE STROBE NOW FIRE STROBE NOW FIRE STROBE NOW BREAK AT LINE 5215 OK >RUN LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 9 ENABLE DATA CAPTURE AND PRESS RETURN TO CONTINUE 169 191 191 34 34 236 170 191 191 33 28 236 LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 1 THE YEAR IS (0 TO 99) 10 THE MONTH IS (1 TO 12) 05 THE DAY IS (1 TO 31) 14 THE HOUR IS (0 TO 23) 15 THE MINUTE IS (0 TO 59) 42 THE SECOND IS (0 TO 59) 00 THE TIME IS: 15:42:0 on 5/14/10 HIT RETURN TO CONTINUE LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 2 MAIN DELAY TIME IN MIN 60 RIGHT STROBE CHARGE TIME IN SEC 45 LEFT STROBE CHARGE TIME IN SEC 45 P-LINE TIME IN mSEC 200 MAIN TIME = 60 MIN R-STROBE = 45 SEC L-STROBE = 45 SEC PLINE = 200 mSEC HIT RETURN TO CONTINUE LONG-TERM CAMERA TRIPOD MAIN MENU V1.1 1 - SET CLOCK 2 - SET SYSTEM VARIABLES 3 - TEST MENU 4 - DEPLOY 9 - OFFLOAD DATA ENTER SELECTION 4 ENTER DEPLOYMENT DELAY TIME IN HOURS: 0 MAIN LOOP TIME: 60 MIN R-STROBE CHARGE TIME: 45 SEC L-STROBE CHARGE TIME: 45 SEC P-LINE ACTIVE TIME: 200 mSEC THE TIME IS: 15:42:21 on 5/14/10 CAMERA WILL START IN: 0 HOURS REMOVE COMM. CABLE AND DEPLOY FIRE STROBE NOW FIRE STROBE NOW FIRE STROBE NOW