ûûûÝ÷ÿûÿÝÿûûÝûûÝû÷ÿûýûÿûÝûûý{ReRunBootingFlashApp() Program: H2oûReRunBootingFlashApp() Program: H2ocon_init.c: Aug 12 2003 16:41:59 Persistor CF2 SN:1411 BIOS:2.27 PicoDOS:2.27 ReRunBootingFlashApp() Program: H2ocon_init.c: Aug 12 2003 16:41:59 Persistor CF2 SN:1411 BIOS:2.27 PicoDOS:2.27 ---------------------------------------------------------------- Persistor CF2: SN 01411 - PicoDOS V2.27 - BIOS V2.27 - PBM V2.27 (C) 1998-2002 Persistor Instruments Inc. - www.persistor.com ---------------------------------------------------------------- C:\>dir Volume in drive C is NONAME Volume Serial Number is 778B-2005 Directory of C:\ CAM1_14.TXT 6,921 08-03-05 9:23a BIN 08-25-03 8:43p CAM1_23.TXT 6,866 08-03-05 9:26a SETTINGS.DAT 12 08-03-05 9:19a H2OCTRL.PXE 59,876 08-02-05 1:41p 4 file(s) 73,675 bytes 1 dir(s) 1,023,918,080 bytes free C:\>del camdel cam*.* C:\>dir Volume in drive C is NONAME Volume Serial Number is 778B-2005 Directory of C:\ BIN 08-25-03 8:43p SETTINGS.DAT 12 08-03-05 9:19a H2OCTRL.PXE 59,876 08-02-05 1:41p 2 file(s) 59,888 bytes 1 dir(s) 1,023,950,848 bytes free C:\>h20octrl. Program: H2OCtrl.c: Aug 2 2005 13:41:55 Persistor CF2 SN:1411 BIOS:2.27 PicoDOS:2.27 H2O Controller Main Menu =========================================== 1.) Original Command Mode 2.) Setup Parameters 3.) Run Continuous Test 9.) Exit =========================================== Enter Selection: [9] ? 2 Setup Menu =========================================== 1.) Set System Date and Time 2.) Set Sample Rate and Camera Options 3.) Set Strobe Parameters 4.) Set PC104 Parameters 9.) Exit Setup (will save changes) =========================================== Enter Selection: [9] ? 1 Enter the Date and Time [08/03/05 14:59:31] ? Current RTC Clock Time: Wed Aug 3 14:59:35 2005 Setup Menu =========================================== 1.) Set System Date and Time 2.) Set Sample Rate and Camera Options 3.) Set Strobe Parameters 4.) Set PC104 Parameters 9.) Exit Setup (will save changes) =========================================== Enter Selection: [9] ? 2 Enter Sample Rate (min): [10] ? Camera 1 Enabled: [Y] ? Camera 2 Enabled: [N] ? Setup Menu =========================================== 1.) Set System Date and Time 2.) Set Sample Rate and Camera Options 3.) Set Strobe Parameters 4.) Set PC104 Parameters 9.) Exit Setup (will save changes) =========================================== Enter Selection: [9] ? 3 Enter High Strobe Charge Time (sec): [90] ? Enter Low Strobe Charge Time (sec): [30] ? Setup Menu =========================================== 1.) Set System Date and Time 2.) Set Sample Rate and Camera Options 3.) Set Strobe Parameters 4.) Set PC104 Parameters 9.) Exit Setup (will save changes) =========================================== Enter Selection: [9] ? 4 Enter the Bootup Time (sec): [60] ? Enter the Camera Time (sec): [45] ? Setup Menu =========================================== 1.) Set System Date and Time 2.) Set Sample Rate and Camera Options 3.) Set Strobe Parameters 4.) Set PC104 Parameters 9.) Exit Setup (will save changes) =========================================== Enter Selection: [9] ? H2O Controller Main Menu =========================================== 1.) Original Command Mode 2.) Setup Parameters 3.) Run Continuous Test 9.) Exit =========================================== Enter Selection: [9] ? 3 Press '!' to end continuous test... NOTE: you will have to wait for the current cycle to end. Camera 1 with Strobe 1 and 4... Charging high power strobe...wait 60 seconds Charging low power strobe...wait 30 seconds Camera PC104 power on...wait 60 seconds Camera D60 on...wait 5 seconds Camera picture about to be taken/downloaded to PC-104 (wait 45 secs) Camera picture downloaded...shutting down camera Camera system off Done. Camera 1 with Strobe 2 and 3... Charging high power strobe...wait 60 seconds Charging low power strobe...wait 30 seconds Camera PC104 power on...wait 60 seconds Camera D60 on...wait 5 seconds Camera picture about to be taken/downloaded to PC-104 (wait 45 secs) Camera picture downloaded...shutting down camera Camera system off Done. One set complete... Camera 1 with Strobe 1 and 4... Charging high power strobe...wait 60 seconds Charging low power strobe...wait 30 seconds Camera PC104 power on...wait 60 seconds Camera D60 on...wait 5 seconds Camera picture about to be taken/downloaded to PC-104 (wait 45 secs) Camera picture downloaded...shutting down camera Camera system off Done. Camera 1 with Strobe 2 and 3... Charging high power strobe...wait 60 seconds Charging low power strobe...wait 30 seconds Camera PC104 power on...wait 60 seconds Camera D60 on...wait 5 seconds Camera picture about to be taken/downloaded to PC-104 (wait 45 secs) Camera picture downloaded...shutting down camera Camera system off Done. H2O Controller Main Menu =========================================== 1.) Original Command Mode 2.) Setup Parameters 3.) Run Continuous Test 9.) Exit =========================================== Enter Selection: [9] ? ---------------------------------------------------------------- Persistor CF2: SN 01411 - PicoDOS V2.27 - BIOS V2.27 - PBM V2.27 (C) 1998-2002 Persistor Instruments Inc. - www.persistor.com ---------------------------------------------------------------- C:\>dir Volume in drive C is NONAME Volume Serial Number is 778B-2005 Directory of C:\ CAM1_14.TXT 204 08-03-05 3:13p BIN 08-25-03 8:43p CAM1_23.TXT 204 08-03-05 3:17p SETTINGS.DAT 12 08-03-05 2:59p H2OCTRL.PXE 59,876 08-02-05 1:41p 4 file(s) 60,296 bytes 1 dir(s) 1,023,918,080 bytes free C:\>type cam1_14.txt Camera 1, Strobes 1 (high) & 4 (low) Date Cam1Vlt S1Chrgd Dischgd S4Chrgd Dischgd 08/03/05 15:02 0.00 0.00 0.00 0.00 0.00 08/03/05 15:12 0.00 0.00 0.00 0.00 0.00 C:\>h2octrl Program: H2OCtrl.c: Aug 2 2005 13:41:55 Persistor CF2 SN:1411 BIOS:2.27 PicoDOS:2.27 H2O Controller Main Menu =========================================== 1.) Original Command Mode 2.) Setup Parameters 3.) Run Continuous Test 9.) Exit =========================================== Enter Selection: [9] ? 1 H2OCON: status 48V = 23.51 Volts 5V = 4.99 Volts GFI = 1.45 mA TILT_X = -0.27 TILT_Y = -0.02 GND = 0 H2OCON: status 48V = 24.53 Volts 5V = 4.99 Volts GFI = 0.00 mA TILT_X = -0.18 TILT_Y = 0.02 GND = 0 H2OCON: stauttus 48V = 29.44 Volts 5V = 4.99 Volts GFI = 0.00 mA TILT_X = -0.31 TILT_Y = 0.00 GND = 0 H2OCON: status 48V = 39.91 Volts 5V = 4.99 Volts GFI = 0.00 mA TILT_X = -0.07 TILT_Y = 0.16 GND = 0 H2OCON: reset ---------------------------------------------------------------- Persistor CF2: SN 01411 - PicoDOS V2.27 - BIOS V2.27 - PBM V2.27 (C) 1998-2002 Persistor Instruments Inc. - www.persistor.com ---------------------------------------------------------------- C:\>h2octrl Program: H2OCtrl.c: Aug 2 2005 13:41:55 Persistor CF2 SN:1411 BIOS:2.27 PicoDOS:2.27 H2O Controller Main Menu =========================================== 1.) Original Command Mode 2.) Setup Parameters 3.) Run Continuous Test 9.) Exit =========================================== Enter Selection: [9] ? 1 H2OCON: stautus 48V = 40.06 Volts 5V = 4.99 Volts GFI = 0.00 mA TILT_X = 0.00 TILT_Y = -0.07 GND = 0 H2OCON: status 48V = 40.04 Volts 5V = 5.00 Volts GFI = 0.00 mA TILT_X = -0.24 TILT_Y = -0.13 GND = 0 H2OCON: reset ---------------------------------------------------------------- Persistor CF2: SN 01411 - PicoDOS V2.27 - BIOS V2.27 - PBM V2.27 (C) 1998-2002 Persistor Instruments Inc. - www.persistor.com ---------------------------------------------------------------- C:\>