# Control System Configuration File # # Soil Machine Dynamics Ltd # Wincomblee Rd, Low Walker # Newcastle-upon-Tyne, UK # NE6 3QS. # Tel: +00 44 (0)191-234-2222 # Fax: +00 44 (0)191-234-0444 # # Note: no spaces after the '=' for text items. # this bug to be sorted. # # General configuration items # Test [FIELDBUS_IO] TotalNodes=2 Debug=1 Verbose=1 CRC_Enable=1 NonBlocking=1 RegisterName=SMD/FBUS OutputControl=1 UpdateRate=200000000 RS485Delay=100 ############## 342 TEST NODE ################## [NODE_1] # Specify Node Type # # WAGO-750-342 Ethernet Coupler # WAGO-RS485 RS485 Coupler # SMART-RS485 SMD smart I/O module # NodeType=WAGO-750-342 MAC_Address=134.89.12.113 PortAddress=502 # How many modules are installed on this node (Max 64) MaxModules=2 # For each module installed define its type from the following list: # DI2 DI4 DI8 DO2 DO4 DO8 AI1 AI2 AI4 AO1 AO2 AO4 CT CT_R # Module1=DI8 Module2=DO8 ############## 316 TEST NODE ################## [NODE_2] # Specify Node Type # # WAGO-750-342 Ethernet Coupler # WAGO-RS485 RS485 Coupler # SMART-RS485 SMD smart I/O module # NodeType=WAGO-RS485 NodeID=1 Port=/dev/ser1 PortSettings=19200,8,n,1 # How many modules are installed on this node (Max 64) MaxModules=2 # For each module installed define its type from the following list: # DI2 DI4 DI8 DO2 DO4 DO8 AI1 AI2 AI4 AO1 AO2 AO4 CT CT_R # Module1=DI8 Module2=DO8