Acumen Instruments Corporation 08/22/2013 22:19:55 DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0016.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure Data Port for attached device R Start recording (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) 5 Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 3600.000 N N Y Y atto0,1 1 4200.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 0 Enter output interval in seconds (0-4294967): 32 4200 Initialize with message (Y/N)? N Send message when stopping (Y/N)? N Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 34200.000 N N Y Y atto0,1 1 4200.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 1 Enter output interval in seconds (0-4294967): 34800 Initialize with message (Y/N)? N Send message when stopping (Y/N)? Y Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 34200.000 N N Y Y atto0,1 1 34800.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 2 Enter output interval in seconds (0-4294967): 68405 Initialize with message (Y/N)? N Send message when stopping (Y/N)? N Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 34200.000 N N Y Y atto0,1 1 34800.000 N Y Y Y atto0,0 2 68405.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 3 Enter output interval in seconds (0-4294967): 69000 Initialize with message (Y/N)? N Send message when stopping (Y/N)? Y Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 34200.000 N N Y Y atto0,1 1 34800.000 N Y Y Y atto0,0 2 68405.000 N N Y Y atto1,1 3 69000.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 4 Enter output interval in seconds (0-4294967): 70500 Initialize with message (Y/N)? N Send message when stopping (Y/N)? Y Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 34200.000 N N Y Y atto0,1 1 34800.000 N Y Y Y atto0,0 2 68405.000 N N Y Y atto1,1 3 69000.000 N Y Y Y atto1,0 4 70500.000 N Y Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 5 Enter output interval in seconds (0-4294967): 71700 Initialize with message (Y/N)? N Send message when stopping (Y/N)? Y Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 34200.000 N N Y Y atto0,1 1 34800.000 N Y Y Y atto0,0 2 68405.000 N N Y Y atto1,1 3 69000.000 N Y Y Y atto1,0 4 70500.000 N Y Y Y atm1 5 71700.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) q Acumen Instruments Corporation 08/22/2013 22:23:39 DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0016.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure Data Port for attached device R Start recording (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R)