5 Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 3600.000 N N Y Y atto0,1 1 4200.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 8410.000 N N Y Y atm1 5 9600.000 N Y Y Y atm0 6 0.000 Y N Y Y atv 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 4 Enter output interval in seconds (0-4294967): 7800 Initialize with message (Y/N)? N Send message when stopping (Y/N)? N Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 3600.000 N N Y Y atto0,1 1 4200.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9600.000 N Y Y Y atm0 6 0.000 Y N Y Y atv 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 -----Message Settings----- Enter message number (0-9): 5 Enter output interval in seconds (0-4294967): 9000 Initialize with message (Y/N)? N Send message when stopping (Y/N)? Y Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 3600.000 N N Y Y atto0,1 1 4200.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atv 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 1 Enter message number (0-9): 6 Use \hh for hex entry, \tnnnn for millisecond delay, and \\ for \ Enter message (press Enter to end): atr0 Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 3600.000 N N Y Y atto0,1 1 4200.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5400.000 N Y Y Y atto1,0 4 7800.000 N N Y Y atm1 5 9000.000 N Y Y Y atm0 6 0.000 Y N Y Y atr0 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) q Acumen Instruments Corporation 08/20/2013 17:56:40 DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0013.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure Data Port for attached device R Start recording (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) 6 Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0013.DAT 1 Specify current file 2 Toggle overwrite-oldest mode (overwrite is OFF) 3 Toggle append mode (append is OFF) 4 Configure scheduled file closing (OFF) 5 Configure time stamping (trigger on 0x0A, "MM/DD/YYYY hh:mm:ss") 6 Power up in passthrough mode (passthrough mode is OFF) 7 Operate in low-power mode (low-power mode is ON) 8 Flush buffer when recording starts (flushing is OFF) 9 Disable indicators (indicators are OFF) Q Return to main menu Enter choice (1,2,3,4,5,6,7,8,9,Q) q Acumen Instruments Corporation 08/20/2013 17:57:11 DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0013.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure Data Port for attached device R Start recording (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) 8 Entering passthrough mode. Type +++ then pause to return to the menu. user:1> 5 user:2>Lowpower user:2> Invalid Command user:3> 005 user:4>Lowpower 53977 user:5> -559 user:6> user:6> -559 user:7>