55 Acumen Instruments Corporation DataBridge SDR2-CF rev. 1.2.072811 # interval I S CR LF message 0 3600.000 N N Y Y atto0,1 1 4500.000 N Y Y Y atto0,0 2 4800.000 N N Y Y atto1,1 3 5700.000 N Y Y Y atto1,0 4 9000.000 N N Y Y atm1 5 9900.000 N Y Y Y atm0 6 0.000 N N Y Y 7 0.000 N N Y Y 8 0.000 N N Y Y 9 0.000 N N Y Y 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) qq Acumen Instruments Corporation 04/02/2013 15:46:39 DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0006.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure Data Port for attached device R Start recording (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) 88 Entering passthrough mode. Type +++ then pause to return to the menu. user:21>@mode Bad parameter! Error user:22>@Modem S| Modem Params | Value | Range --+------------------+-------------+------------------------------------- 7| AcRspTmOut | 7.5000 | 2.0 - 99.5 sec (0.5 sec increments) 2| DataRetry | 0 | 0..6 28| DevEnable | 0 (Auto) | 0 (Auto), 1 (MBARI), 2 (Manual-LP), | | | 3 (Manual) 8| FwdDelay | 3.0000 | 0.05 to 5 sec (50ms increments) 18| LocalAddr | 5 | 0..249 15| OpMode | 0 (Command) | 0 (Command), 1 (Online), 2 (Datalog), | | | 6 (ContXpnd) | PrintHex | Dis | Ena, Dis 14| RemoteAddr | 0 | 0 - 249, 255 5| ^RxPktType | 0 (MFSK) | 0 (MFSK), 2 (Xpnd), 3 (Chirp) 16| ShowBadData | Ena | Ena, Dis | SmartRetry | Dis | Ena, Dis | StartTones | Ena | Ena, Dis | StrictAT | Dis | Ena, Dis 4| TxRate | 5 (800) | 2 (140), 3 (300), 4 (600), | | | 5 (800), 6 (1066), 7 (1200), | | | 8 (2400), 9 (2560), 10 (5120), | | | 11 (7680), 12 (10240), 13 (15360) 6| TxPower | 7 (-3dB) | 1 (-21dB), 2 (-18dB), 3 (-15dB), | | | 4 (-12dB), 5 (-9dB), 6 (-6dB), | | | 7 (-3dB), 8 (Max) 17| WakeTones | Ena | Ena, Dis user:23>@Release S| Release Params | Value | Range --+------------------+-------------+------------------------------------- 51| ^FSKRlsDur | 8 | 4..12 39| ^LstCommsCnt | 0 | 0..999 41| ^RlsCode | 55363 | 0..65535 50| TimedRelease | 0 | Release in 0-999 hours user:24>@ Version Serial System Coproc Datalog Modem Release Transport Test Xpnd Nav user:25>+++ Acumen Instruments Corporation 04/02/2013 15:47:13 DataBridge SDR2-CF rev. 1.2.072811 Current filename:\DATA\SDR-0006.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure Data Port for attached device R Start recording (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R)