Acumen Instruments Corporation 02/04/2009 11:09:28 DataBridge SDR2-CF rev. 1.0 Current filename:\DATA\SDR-0001.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure data port for attached device R Enter record mode (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) 8 Entering passthrough mode. Type +++ then pause to return to the menu. Local Sregisters S00=067 S01=000 S02=000 S03=002 S04=005 S05=000 S06=008 S07=004 S08=060 S09=000 S10=036 S11=000 S12=000 S13=001 S14=000 S15=000 S16=000 S17=001 S18=000 S19=000 S20=000 > Factory Sregisters S21=010 S22=000 S23=001 S24=056 S25=150 S26=027 S27=028 S28=000 S29=000 S30=008 S31=004 S32=128 S33=000 S34=005 S35=000 S36=-001 S37=000 S38=000 S39=000 S40=000 S41=-018 > Acumen Instruments Corporation 02/04/2009 11:10:49 DataBridge SDR2-CF rev. 1.0 Current filename:\DATA\SDR-0001.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure data port for attached device R Enter record mode (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) 5 Acumen Instruments Corporation 02/04/2009 11:10:52 DataBridge SDR2-CF rev. 1.0 # interval I S CR LF message 0 10000 N N Y Y +++ 1 300 N N Y Y atn12000 2 10001 Y N Y Y atto0,1 3 2400 N Y Y Y atto0,0 4 3600 N N Y Y atto1,1 5 6300 N N Y Y atto1,0 6 7200 N N Y Y atm1 7 9900 N N Y Y atm0 8 0 N N N N 9 0 N N N N 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) 2 Enter message number (0-9): 0 Enter output interval in seconds (0-4294967295): 20000 Initialize with message (Y/N)? N Send message when stopping (Y/N)? N Append carriage return to message (Y/N)? Y Append line feed to message (Y/N)? Y Acumen Instruments Corporation 02/04/2009 11:11:07 DataBridge SDR2-CF rev. 1.0 # interval I S CR LF message 0 20000 N N Y Y +++ 1 300 N N Y Y atn12000 2 10001 Y N Y Y atto0,1 3 2400 N Y Y Y atto0,0 4 3600 N N Y Y atto1,1 5 6300 N N Y Y atto1,0 6 7200 N N Y Y atm1 7 9900 N N Y Y atm0 8 0 N N N N 9 0 N N N N 1 Edit message contents 2 Edit message parameters Q Return to main menu Enter choice (1,2,Q) q Acumen Instruments Corporation 02/04/2009 11:21:34 DataBridge SDR2-CF rev. 1.0 Current filename:\DATA\SDR-0001.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure data port for attached device R Enter record mode (recording is OFF) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,R) r Entering record mode... Acumen Instruments Corporation 02/04/2009 11:35:14 DataBridge SDR2-CF rev. 1.0 Current filename:\DATA\SDR-0002.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure data port for attached device R Enter record mode (recording is ON) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,S) m Acumen Instruments Corporation 02/04/2009 11:35:41 DataBridge SDR2-CF rev. 1.0 Current filename:\DATA\SDR-0002.DAT 1 Set time 2 Set date 3 Toggle ANSI mode (ANSI is OFF) 4 Toggle messages (messages are ON) 5 Edit messages... 6 Recording parameters... 7 File system functions... 8 Enter serial passthrough mode 9 Configure data port for attached device R Enter record mode (recording is ON) S Stop recording Enter choice (1,2,3,4,5,6,7,8,9,S)