OK user:20> Local Sregisters S00=086 S01=000 S02=000 S03=002 S04=005 S05=000 S06=004 S07=015 S08=060 S09=001 S10=255 S11=000 S12=129 S13=001 S14=002 S15=001 S16=001 S17=001 S18=000 S19=000 S20=000 user:21> CONNECT 00800 bits/sec BEDS)> BEDS)>dir Volume in drive C has no label Volume Serial Number is 413C-297A Directory of C:\ BEDS.CFG 271 10-08-15 8:52a BEDSCLK.001 8 10-09-15 9:10a EVENTIDX.001 18 10-09-15 9:09a WATCHIDX.001 50 10-09-15 9:10a EVENTIDX.002 18 10-08-15 4:49p WATCHIDX.002 50 10-08-15 4:49p BEDS.CLK 1,920 10-09-15 1:11p SYSLOG.001 933 10-09-15 9:11a MPULOG.001 342 10-09-15 9:10a BEDS.BAK 246 10-08-15 8:25a MPULOG.002 342 10-08-15 4:49p SYSLOG.TXT 5,139 10-09-15 1:12p 20200001.WAT 3,966 10-09-15 9:12a RTC.PXE 28,270 10-08-15 8:16a BEDSCLK.002 8 10-08-15 4:49p EVENT.IDX 18 10-09-15 9:12a WATCH.IDX 114 10-09-15 1:12p SYSLOG.002 657 10-08-15 4:49p MPULOG.TXT 5,314 10-09-15 11:33a 20200002.WAT 9,006 10-09-15 9:14a 20200003.WAT 2,656,914 10-09-15 1:12p 21 file(s) 2,650 KB 0 dir(s) 31,239,360 KB free BEDS)>analog Channel 0 = 57871 counts 2.21 volts 26.734 Batt Volts Channel 1 = 57930 counts 2.21 volts 26.761 Batt Volts Channel 2 = 6337 counts 0.24 volts -0.413 bar Channel 3 = 14586 counts 0.56 volts 15.321 psia Channel 4 = 18784 counts 0.72 volts 21.655 degC Channel 5 = 22035 counts 0.84 volts 15.834 % BEDS)>analog Channel 0 = 57650 counts 2.20 volts 26.632 Batt Volts Channel 1 = 57707 counts 2.20 volts 26.658 Batt Volts Channel 2 = 6341 counts 0.24 volts -0.406 bar Channel 3 = 14584 counts 0.56 volts 15.317 psia Channel 4 = 18823 counts 0.72 volts 21.804 degC Channel 5 = 21996 counts 0.84 volts 15.764 % BEDS)>deletechar 1 beds.cfg Privilege violation BEDS)>priv 100 Setting command parser privilege to 100 BEDS)>deletechar 1 beds.cfg BEDS)>type beds.cfg START 10/12/2015 6:00:00 platformID = 2 ModemAddr = 2 deploymentID = 2 ModemPower = 6 #logToConsole = 3 Timeout = 120 ModemWarmup = 15 ModemOnTime = 60 ModemOffset = 120 SensorWarmup = 5 SensorMinSecs = 10 deployModeSecs = 381600 NoMotionThresh = 12.0 BEDS)>reset This could cause permanent loss of communication. Are you really sure [N] ? BEDS)> BEDS)>time Accurate time is: Friday October 09, 2015 01:16:35.993 pm Persistor clock is 0.019 seconds behind accurate clock BEDS)>deployModeSecs = 614400 DeployModeSecs = 604800 Variable out of range; adjusted BEDS)> BEDS)>quit BEDS)> BEDS)>deploy Deployment mode = ON BEDS)>deploymode           BEDS)>var dejpjl          var deploymodesecs DeployModeSecs = 604800 How long (seconds) to stay in deployment mode BEDS)>analog Channel 0 = 57419 counts 2.19 volts 26.525 Batt Volts Channel 1 = 57485 counts 2.19 volts 26.556 Batt Volts Channel 2 = 6335 counts 0.24 volts -0.417 bar Channel 3 = 14585 counts 0.56 volts 15.319 psia Channel 4 = 18974 counts 0.72 volts 22.380 degC Channel 5 = 21701 counts 0.83 volts 15.233 % BEDS)>quit