+++ user:11>atd11 Response Not Received user:12>atd11 Response Not Received user:13>atd11 CONNECT 00800 bits/sec BEDS)> BEDS)>time time Accurate time is: Wednesday September 28, 2016 05:00:43.028 pm Persistor clock is 0.255 seconds behind accurate clock BEDS)>more beds.cfg more beds.cfg 0001: platformID = 11 0002: ModemAddr = 11 0003: deploymentID = 1 0004: ModemPower = 6 0005: logToConsole = 3 0006: Timeout = 120 0007: WatchFreq = 2 0008: ModemWarmup = 15 0009: ModemOnTime = 60 0010: ModemOffset = 1200 0011: SensorWarmup = 2 0012: SensorMinSecs = 10 0013: NoMotionTime = 5.0 0014: 0015: NoMotionThresh = 12.0 0016: MaxEvent = 7200 0017: DeployModeSecs = 172800 0018: BEDS)>insertline 5 beds.cfg BEDS)>more beds.cfg more beds.cfg 0001: platformID = 11 0002: ModemAddr = 11 0003: deploymentID = 1 0004: ModemPower = 6 0005: logToConsole = 3 0006: Timeout = 120 0007: WatchFreq = 2 0008: ModemWarmup = 15 0009: ModemOnTime = 60 0010: ModemOffset = 1200 0011: SensorWarmup = 2 0012: SensorMinSecs = 10 0013: NoMotionTime = 5.0 0014: 0015: NoMotionThresh = 12.0 0016: MaxEvent = 7200 0017: DeployModeSecs = 172800 0018: BEDS)>insertline 5 beds.cfg BEDS)>insertline 5 beds.cfg insertline 5 beds.cfg Privilege violation BEDS)>priv 100 BEDS)>i BEDS)>insertline 5 beds.cfg insertline 5 beds.cfg Privilege violation BEDS)>priv 100 BEDS)>analog analog Channel 0 = 58388 counts 2.23 volts 26.973 Batt Volts Channel 1 = 58804 counts 2.24 volts 27.165 Batt Volts Channel 2 = 6341 counts 0.24 volts -0.406 bar Channel 3 = 14408 counts 0.55 volts 14.981 psia Channel 4 = 18489 counts 0.71 volts 20.530 degC Channel 5 = 47803 counts 1.82 volts 62.205 % BEDS)>priv 100 priv 100 Setting command parser privilege to 100 BEDS)>insertline 5 beds.cfg insertline 5 beds.cfg 0006: logToConsole = 3 ModemPower = 8 ModemPower = 8 BEDS)>incsertchars 4 beds.cfg inc sertchars 4 beds.cfg0005: 0004: ModemPower = 6 # # BEDS)>type beds.cfg type beds.cfg platformID = 11 ModemAddr = 11 deploymentID = 1 #ModemPower = 6 ModemPower = 8 logToConsole = 3 Timeout = 120 WatchFreq = 2 ModemWarmup = 15 ModemOnTime = 60 ModemOffset = 1200 SensorWarmup = 2 SensorMinSecs = 10 NoMotionTime = 5.0 NoMotionThresh = 12.0 MaxEvent = 7200 DeployModeSecs = 172800 BEDS)>time time0004: Accurate time is: Wednesday September 28, 2016 05:06:45.424 pm Persistor clock is 0.255 seconds behind accurate clock BEDS)>var var PlatformID = 11 Platform ID DeploymentID = 1 Deployment ID EvtFreq = 50 Sample rate during event (Hz) WatchFreq = 2 Sample rate in watch cycle (Hz) EvtPressureSecs = 1 Sample rate (sec) for pressure sensor during event SysRecSecs = 600 Sample rate (secs) for getting system parameters during watch cycle AccelRange = 16 Accelerometer range in g's (2, 4, 8, or 16) GyroRange = 2000 Gyro range in degrees/sec (250, 500, 1000, or 2000) DigitalFilterBW = 42 Bandwidth of MPU digital filter, Hz (5, 10, 20, 42, 98, 188, or 256) debugBaud = 9600 Baud rate to use on DEBUG port ---More--- modemBaud = 9600 Baud rate to acoustic modem Timeout = 120 Timeout on user I/F (secs) ModemPeriod = 3600 Period (secs) for checking acoustic Modem DeployModemPeriod = 600 Modem Period during deployment mode DeployModeSecs = 172800 How long (seconds) to stay in deployment mode ModemOffset = 1200 Offset (secs) from top of ModemPeriod ModemOnTime = 60 Period we leave modem on (secs) ModemWarmup = 15 Warmup time for turning on acoustic modem, secs ModemWait = 5 Time before turning off acoustic modem, secs ModemAddr = 11 Acoustic Modem address ---More--- ModemPower = 6 Acoustic Modem Transmit power (S6 setting) InitModem = TRUE Send init strings to acoustic modem at startup SensorWarmup = 2 Warmup time for turning on system sensors, secs SensorMinSecs = 10 If SysRecSys < this, leave sensors on MaxEvent = 7200 Maximum time for an event (secs) NoMotionThresh = 12.00 No motion threshold, deg/sec NoMotionTime = 5.00 No motion time (secs) PressFullScale = 100.00 Full scale for pressure sensor (bar) Echo = TRUE Echo user commands zmSetRemote = TRUE Use remote cmds to set SRegs for ZModem ---More--- kermitTimeout = 30 Timeout (secs) for kermit protocol InitPicoClock = TRUE Initialize PicoDOS clock at startup logToConsole = 3 0=no echo, 1=echo to console, 2=echo to TPU BEDS)>reset reset This could cause permanent loss of communication. Are you really sure [N] ? y +++ user:14> user:14>atd11 CONNECT 00800 bits/sec BEDS)> BEDS)>analog analog Channel 0 = 58321 counts 2.22 volts 26.942 Batt Volts Channel 1 = 58609 counts 2.24 volts 27.075 Batt Volts Channel 2 = 6351 counts 0.24 volts -0.386 bar Channel 3 = 14407 counts 0.55 volts 14.979 psia Channel 4 = 18479 counts 0.70 volts 20.492 degC Channel 5 = 47703 counts 1.82 volts 62.026 % BEDS)>modem ats? modem ats? Privilege violation BEDS)>priv 100 priv 100 Setting command parser privilege to 100 BEDS)>modem ats? modem ats? Modem returns: Local Sregisters S00=810 S01=000 S02=000 S03=002 S04=005 S05=000 S06=008 S07=015 S08=010 S09=000 S10=036 S11=000 S12=000 S13=000 S14=000 S15=001 S16=001 S17=001 S18=011 S19=000 S20=000 user:2> BEDS)>analog analog Channel 0 = 53607 counts 2.04 volts 24.764 Batt Volts Channel 1 = 49897 counts 1.90 volts 23.050 Batt Volts Channel 2 = 6349 counts 0.24 volts -0.390 bar Channel 3 = 14407 counts 0.55 volts 14.979 psia Channel 4 = 18513 counts 0.71 volts 20.621 degC Channel 5 = 47596 counts 1.82 volts 61.833 % BEDS)> TIMEOUT