[Global] AddressMode=Flat [Module.Root] Id=2 Name=Steuerungskonfiguration SubModul1=Type=Var,Class=BUSMASTER SubModul2=Type=Var,Class=CARD Icon=Plcconf.ico [Module.CanDevice] Name=CanDevice Id=78379 DeviceType=CANDEVICE BasisPrmDlg=FALSE Class=BUSMASTER Icon=codsmall.ico [Module.CanMaster] Name=CanMaster Id=5 DeviceType=CANMASTER OnlineMode=0xB NodeIdEditable=Yes AdrEditable=Yes Class=BUSMASTER Icon=codsmall.ico SubModul1=Type=Var,Class=CAN_SLAVE Param1=Name=UpdateTask,Section=TaskName Param2=Name='Control Mode',Section=ModeType Param3=Name='Watchdog Time',Section=WatchdogType Param4=Name='Start bus before inputs',Section=StartBusType Param5=Name='Stop bus in PLC stop',Section=DisableBusInStop [Module.CanSlave] Name=CanSlave Id=693734 DeviceType=CANSLAVE OnlineMode=0x4 SymbolicNames=unlocked NodeIdEditable=Yes AdrEditable=Yes Class=CAN_SLAVE Icon=Vis.ico ExcludeEntries='filename' OptionalDevice=FALSE NoInitialize=FALSE [Module.CanSlaveOld] Name=CanSlaveOld Id=693734 DeviceType=CANSLAVE OnlineMode=0x4 SymbolicNames=unlocked NodeIdEditable=Yes AdrEditable=Yes Class=CAN_SLAVE Icon=Vis.ico OldStyleMapping=TRUE PossibleEntries='filename' [Module.DPMaster] Name=DP-Master Id=983083 DeviceType=DPMASTER OnlineMode=0xB CreateBitChannels=TRUE BitChannelIcon=Globsmal.ICO NodeIdEditable=Yes AdrEditable=Yes Class=BUSMASTER Icon=ODEditor.ico SubModul1=Type=Var,Class=DP_SLAVE Param1=Name=UpdateTask,Section=TaskName Param2=Name='Byteorder wordmodules motorola',Section=ByteOrder Param3=Name='Control Mode',Section=ModeType Param4=Name='Watchdog Time',Section=WatchdogType Param5=Name='Start bus before inputs',Section=StartBusType Param6=Name='Stop bus in PLC stop',Section=DisableBusInStop [Module.DPSlave] Name=DPSlave Id=69230394 DeviceType=DPSLAVE OnlineMode=0x4 SymbolicNames=unlocked NodeIdEditable=Yes AdrEditable=Yes EnableChannelEdit=TRUE Class=DP_SLAVE Icon=plcbrowse.ico [Module.DPSlave2] Name=DPSlave Id=69230394 DeviceType=DPSLAVE OnlineMode=0x4 SymbolicNames=unlocked NodeIdEditable=Yes AdrEditable=Yes EnableChannelEdit=TRUE Class=BUSMASTER Icon=plcbrowse.ico PossibleEntries='HIL_049F.GSD' SingleSlave=FALSE ShowDPDialog=TRUE [Parameter.BoolType] Id=10001 Type=INT Class=Symbolic Help=TTHelp ;TTHelp=Hier könnten Sie Ihre symbolischen Konstanten beschreiben Symbol1=No Value1=0 Symbol2=Yes Value2=1 Default=2 [Parameter.TaskName] Id=10002 Type=STRING Class=Simple Help=TTHelp TTHelp= The name of the task, which initiates the buscycles. Default=All [Parameter.ByteOrder] Id=10003 Type=INT Class=Symbolic Help=TTHelp TTHelp= The processdata of word-oriented modules are stored in intel/motorola format. Default=0 Symbol1=No Value1=0 Symbol2=Yes Value2=1 [Parameter.ModeType] Id=10004 Type=INT Class=Symbolic Help=TTHelp TTHelp= The control mode of the card. Default=2 Symbol1=Bussync host controlled Value1=0 Symbol2=Buffered host controlled Value2=1 Symbol3=Uncontrolled mode Value3=2 [Parameter.WatchdogType] Id=10005 Type=INT Class=IntType Help=TTHelp TTHelp=Watchdog time of the card Default=0 [Parameter.StartBusType] Id=10006 Type=INT Class=Symbolic Help=TTHelp TTHelp= Start bus cycle before reading inputs. Default=0 Symbol1=No Value1=0 Symbol2=Yes Value2=1 [Parameter.DisableBusInStop] Id=10009 Type=INT Class=Symbolic Help=TTHelp TTHelp= Stop bus in PLC stop. Default=0 Symbol1=No Value1=0 Symbol2=Yes Value2=1