Contents of the disk: Info.txt This file, information about the contents of the disk. 750_307\750-307.eds standard EDS file for the 750-307 CANopen buscoupler 750_307\750-307.dib Bitmap 750_307\750-307.bmp Bitmap for NetCon 750_337\750-337.eds standard EDS file for the 750-337 and 750-337/000-100 CANopen buscoupler 750_337\750-337.dib Bitmap for NetCon 750_337\750-337.bmp Bitmap for NetCon 750_337\750-337_d.dib Bitmap for NetCon 750_337\750-337_r.dib Bitmap for NetCon 750_337\750-337_s.dib Bitmap for NetCon 750_347\750-347.eds standard EDS file for the 750-347 750_347\750-347.dib Bitmap for NetCon 750_347\750-347.bmp Bitmap for NetCon 750_347\750-347_d.dib Bitmap for NetCon 750_347\750-347_r.dib Bitmap for NetCon 750_347\750-347_s.dib Bitmap for NetCon 750_348\750-348.eds standard EDS file for the 750-348 750_348\750-348.dib Bitmap for NetCon 750_348\750-348.bmp Bitmap for NetCon 750_348\750-348_d.dib Bitmap for NetCon 750_348\750-348_r.dib Bitmap for NetCon 750_348\750-348_s.dib Bitmap for NetCon 750_837\750-837.eds standard EDS file for the 750-837 CANopen buscoupler 750_837\750-837.dib Bitmap for NetCon 750_837\750-837.bmp Bitmap for NetCon 750_837\750-837_d.dib Bitmap for NetCon 750_837\750-837_r.dib Bitmap for NetCon 750_837\750-837_s.dib Bitmap for NetCon 752_327\750-327.eds standard EDS file for the 752-327 CANopen module 752_327\750-327.bmp Bitmap 752_327\750-327_d.dib Bitmap for NetCon 752_327\750-327_r.dib Bitmap for NetCon 752_327\750-327_s.dib Bitmap for NetCon NetCon\ example EDS Files for the NetCon and SyCon For configuring the CANopen bus coupler 750-307; 750-337; 750-347; 750-348; 750-337/000-100; 750-837 with a Configuration Tool, the tool has to know about the implemented object dictionary. The EDS-File consist of all objects the bus coupler could have implemented. The amount of implemented objects depends on the amount of connected modules. In the Eds-Fie are the maximum number of objects. Attention: Not to every object in the EDS-file belongs to a module. Mapping of such objects returns an error message from the bus coupler. Pay attention to map only such objects, which are available and represented by modules. Example: The following modules are connected to the bus coupler 750-307: 750-307 CANopen bus coupler 750-550 2-Channel analog output 0-10V 750-400 2-Channel digital input module 750-400 2-Channel digital input module 750-400 2-Channel digital input module 750-400 2-Channel digital input module 750-600 end module The two channels of the analog output module are available at Index 2500, SubIndex 1 and 2. SubIndex 0 has the value 2, that means that 2 SubIndexs are valid. The value in SubIndex 0 of Index 2500 in the EDS File is 128. That means 128 channels are available maximum. This is the case, if 64 x "2-Channel analog output 0-10V modules" are connected at the buscoupler. If you map Index 2500 Subindex 3 (refer to the EDS-File) in our example, then there is no module connected for this SubIndex. The bus coupler returns an error (abort SDO tranfer). As well it is not possible to write data to Index 2500 SubIndex 3.