;============================================================================ ; Geraetestammdatendatei nach DIN 19245 Teil 3 (PROFIBUS-DP) ;============================================================================ ; ; DATEINAME : WAGOB760.GSG ;---------------------------------------------------------------------------- ; GERAET : Binaere E/A Module PROFIBUS-DP 12MBaud ;---------------------------------------------------------------------------- ; GERAETEFAMILIE : WAGO->I/O->SYSTEM 752 ;---------------------------------------------------------------------------- ; PROTOKOLL : PROFIBUS-DP (Slave) ;---------------------------------------------------------------------------- ; HERSTELLER : WAGO Kontakttechnik GmbH ; Hansastrasse 27 ; D-32423 Minden/Westf. ; Telefon: +49 (0) 571 / 887-0 ; Telefax: +49 (0) 571 / 887-169 ;---------------------------------------------------------------------------- ; BEST.-NR. : 752-323 (/...-...) ;---------------------------------------------------------------------------- ; KONTAKT : Herr Detlef Brand ; Telefon: +49 (0) 571 / 887-473 ; Telefax: +49 (0) 571 / 887-8473 ;---------------------------------------------------------------------------- ; VERSION : 1.20 ;---------------------------------------------------------------------------- ; DATUM : 2002-03-01 ;---------------------------------------------------------------------------- ; AENDERUNGEN : ; V1.0 1999-10-31 1. offizelle Version ; V1.1 2000-10-31 Upgrade der GSD-Revision von 1 nach 2 ; aufgrund der PNO-Pruefvorschriften von 02.2000 ; V1.2 2002-03-01 Syntax Aenderungen ; ;============================================================================ #Profibus_DP PrmText = 1 Text(0) = "10 ms" Text(1) = " 1 ms" EndPrmText ExtUserPrmData = 1 "Watchdog-Base" Bit(2) 0 0-1 Prm_Text_Ref = 1 EndExtUserPrmData GSD_Revision = 2 Vendor_Name = "WAGO Kontakttechnik GmbH" Model_Name = "WAGO 752" Revision = "1.00" Ident_Number = 0xB760 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "HW 01" Software_Release = "---" 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Implementation_Type = "LSPM2-ASIC STEP B" Bitmap_Device = "WAGO752N" Bitmap_Diag = "WAGO752S" Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 1 Modular_Station = 0 Modul_Offset = 0 User_Prm_Data_Len = 5 User_Prm_Data = 0x00 , 0x00 , 0x00 , 0x00 , 0x00 Max_User_Prm_Data_Len = 5 Fail_Safe = 0 Slave_Family = 3@WAGO-IO-SYSTEM@BINARY Max_Diag_Data_Len = 13 Ext_User_Prm_Data_Const(0) = 0x00 , 0x00 , 0x00 , 0x00 , 0x00 Ext_User_Prm_Data_Ref(1) = 1 Module = "752-323 16E/16A" 0x21 , 0x11 1 Ext_Module_Prm_Data_Len = 0 EndModule Unit_Diag_Bit (0x0000) = "Fehler in Ausg.-Gruppe 1" Unit_Diag_Bit (0x0001) = "Fehler in Ausg.-Gruppe 2" Unit_Diag_Bit (0x0002) = "Fehler in Ausg.-Gruppe 3" Unit_Diag_Bit (0x0003) = "Fehler in Ausg.-Gruppe 4"