<?xml version="1.0" encoding="UTF-8"?>
<servermain:Project xmlns:servermain="http://www.kepware.com/schemas/servermain"><servermain:Title></servermain:Title><servermain:Comments></servermain:Comments><servermain:AliasList></servermain:AliasList><servermain:ChannelList><servermain:Channel><servermain:Name>Aquarium</servermain:Name><servermain:Driver>Opto22 Ethernet</servermain:Driver><servermain:Ethernet><servermain:NetworkAdapter></servermain:NetworkAdapter></servermain:Ethernet><servermain:WriteOptimizations><servermain:Method>Write last value only</servermain:Method><servermain:WritesToRead>10</servermain:WritesToRead></servermain:WriteOptimizations><servermain:NonNormalizedFloatHandlingType>Replaced with zero</servermain:NonNormalizedFloatHandlingType><servermain:CommunicationSerialization><servermain:VirtualNetwork>None</servermain:VirtualNetwork><servermain:TransactionsPerCycle>1</servermain:TransactionsPerCycle></servermain:CommunicationSerialization><servermain:InterDeviceDelay><servermain:DelayMS>0</servermain:DelayMS></servermain:InterDeviceDelay><servermain:Diagnostics><servermain:Enabled>true</servermain:Enabled><servermain:Identifier>2566738701</servermain:Identifier></servermain:Diagnostics><servermain:DeviceList><servermain:Device><servermain:Name>Aquaria_Rack_0</servermain:Name><servermain:DiagsIdentifier>162964536</servermain:DiagsIdentifier><servermain:Enabled>true</servermain:Enabled><servermain:Simulated>false</servermain:Simulated><servermain:ModelInfo xmlns:opto22_ethernet="http://www.kepware.com/schemas/opto22_ethernet"><opto22_ethernet:Model>Opto22</opto22_ethernet:Model></servermain:ModelInfo><servermain:ID Format="String">134.89.10.92</servermain:ID><servermain:ScanMode>UseClientRate</servermain:ScanMode><servermain:ScanFloorMs>1000</servermain:ScanFloorMs><servermain:Timing><servermain:ConnectionTimeoutSeconds>3</servermain:ConnectionTimeoutSeconds><servermain:ResponseTimeoutMilliseconds>1000</servermain:ResponseTimeoutMilliseconds><servermain:FailAfter>3</servermain:FailAfter></servermain:Timing><servermain:AutoDemotion><servermain:Enabled>false</servermain:Enabled><servermain:DemoteAfter>3</servermain:DemoteAfter><servermain:DemoteForMilliseconds>10000</servermain:DemoteForMilliseconds><servermain:DiscardWrites>false</servermain:DiscardWrites></servermain:AutoDemotion><servermain:AutoTagGeneration><servermain:Startup>Do not generate on startup</servermain:Startup><servermain:DuplicateTagAction>Delete on create</servermain:DuplicateTagAction><servermain:Group></servermain:Group><servermain:AllowSubGroups>true</servermain:AllowSubGroups></servermain:AutoTagGeneration><servermain:CustomDeviceProperties xmlns:opto22_ethernet="http://www.kepware.com/schemas/opto22_ethernet"><opto22_ethernet:Communications><opto22_ethernet:IOUnitProtocol>TCP/IP</opto22_ethernet:IOUnitProtocol><opto22_ethernet:IOUnitPort>2001</opto22_ethernet:IOUnitPort><opto22_ethernet:ControlEnginePort>22001</opto22_ethernet:ControlEnginePort></opto22_ethernet:Communications><opto22_ethernet:TagImport><opto22_ethernet:ImportFile>C:\Users\grda\Desktop\Aquaria_Data v5.bdb</opto22_ethernet:ImportFile></opto22_ethernet:TagImport></servermain:CustomDeviceProperties><servermain:TagList><servermain:Tag><servermain:Name>CO2 ALRM</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[55]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>CO2 ALARM</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>CO2 SW</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[1]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>CO2 SUPPLY</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>CO2 WRN</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[57]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>CO2 WARNING</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>N2 SW</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[0]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>N2 SUPPLY</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>O2 ALRM</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[54]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>O2 ALARM</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>O2 SW</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[2]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>O2 SUPPLY</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>O2 WRN</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[56]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>O2 WARNING</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 C IN</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[63]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 CIRC PUMP INPUT</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 C PMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[49]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 CIRC PUMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 LVL SW</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[53]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 LEVEL SWITCH</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 N2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[17]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 MFC N2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 OPT</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[31]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 OPTODE POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 C IN</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[60]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 CIRC PUMP INPUT</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 C PMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[50]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 CIRC PUMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 CO2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[15]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 MFC CO2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 N2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[14]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 MFC N2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 O2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[16]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 MFC O2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 OPT</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[28]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 OPTODE POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 C IN</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[61]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 CIRC PUMP INPUT</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 C PMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[45]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 CIRC PUMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 CO2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[12]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 MFC CO2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 N2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[11]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 MFC N2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 O2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[13]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 MFC O2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 OPT</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[29]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 OPTODE POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 C IN</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[62]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 CIRC PUMP INPUT</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 C PMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[48]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 CIRC PUMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 CO2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[9]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 MFC CO2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 N2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[8]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 MFC N2 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 O2 PWR</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[10]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 MFC 02 POWER</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 OPT</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.92:2001]STATE[30]</servermain:Address><servermain:DataType>Boolean</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 OPTODE POWER</servermain:Description></servermain:Tag></servermain:TagList></servermain:Device><servermain:Device><servermain:Name>Aquaria_Rack_1</servermain:Name><servermain:DiagsIdentifier>2296145583</servermain:DiagsIdentifier><servermain:Enabled>true</servermain:Enabled><servermain:Simulated>false</servermain:Simulated><servermain:ModelInfo xmlns:opto22_ethernet="http://www.kepware.com/schemas/opto22_ethernet"><opto22_ethernet:Model>Opto22</opto22_ethernet:Model></servermain:ModelInfo><servermain:ID Format="String">134.89.10.98</servermain:ID><servermain:ScanMode>UseClientRate</servermain:ScanMode><servermain:ScanFloorMs>1000</servermain:ScanFloorMs><servermain:Timing><servermain:ConnectionTimeoutSeconds>3</servermain:ConnectionTimeoutSeconds><servermain:ResponseTimeoutMilliseconds>1000</servermain:ResponseTimeoutMilliseconds><servermain:FailAfter>3</servermain:FailAfter></servermain:Timing><servermain:AutoDemotion><servermain:Enabled>false</servermain:Enabled><servermain:DemoteAfter>3</servermain:DemoteAfter><servermain:DemoteForMilliseconds>10000</servermain:DemoteForMilliseconds><servermain:DiscardWrites>false</servermain:DiscardWrites></servermain:AutoDemotion><servermain:AutoTagGeneration><servermain:Startup>Do not generate on startup</servermain:Startup><servermain:DuplicateTagAction>Delete on create</servermain:DuplicateTagAction><servermain:Group></servermain:Group><servermain:AllowSubGroups>true</servermain:AllowSubGroups></servermain:AutoTagGeneration><servermain:CustomDeviceProperties xmlns:opto22_ethernet="http://www.kepware.com/schemas/opto22_ethernet"><opto22_ethernet:Communications><opto22_ethernet:IOUnitProtocol>TCP/IP</opto22_ethernet:IOUnitProtocol><opto22_ethernet:IOUnitPort>2001</opto22_ethernet:IOUnitPort><opto22_ethernet:ControlEnginePort>22001</opto22_ethernet:ControlEnginePort></opto22_ethernet:Communications><opto22_ethernet:TagImport><opto22_ethernet:ImportFile>C:\Users\grda\Desktop\Aquaria_Data v5.bdb</opto22_ethernet:ImportFile></opto22_ethernet:TagImport></servermain:CustomDeviceProperties><servermain:TagList><servermain:Tag><servermain:Name>T-0 N2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[17]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 MFC N2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 pH</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[37]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 PH PROBE</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-0 TEMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[48]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-0 TEMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 CO2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[13]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 MFC CO2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 CO2 CNTS</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[44]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 CO2 COUNTS</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 N2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[12]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 MFC N2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 O2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[16]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 MFC O2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 pH</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[32]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 PH PROBE</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-1 TEMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[49]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-1 TEMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 CO2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[8]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 MFC CO2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 CO2 CNTS</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[45]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 CO2 COUNTS</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 N2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[5]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 MFC N2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 O2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[9]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 MFC O2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 pH</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[33]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 PH PROBE</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-2 TEMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[50]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-2 TEMP</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 CO2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[1]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 MFC CO2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 CO2 CNTS</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[46]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 CO2 COUNTS</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 N2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[0]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 MFC N2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 O2 CMD</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[4]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 MFC O2 COMMAND SIGNAL</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 pH</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[36]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 PH PROBE</servermain:Description></servermain:Tag><servermain:Tag><servermain:Name>T-3 TEMP</servermain:Name><servermain:Address>[MMIO|ip|tcp:134.89.10.98:2001]EU[51]</servermain:Address><servermain:DataType>Float</servermain:DataType><servermain:ReadWriteAccess>Read/Write</servermain:ReadWriteAccess><servermain:RespectGUIDataType>false</servermain:RespectGUIDataType><servermain:Description>T-3 TEMP</servermain:Description></servermain:Tag></servermain:TagList></servermain:Device></servermain:DeviceList></servermain:Channel></servermain:ChannelList><servermain:PlugInList></servermain:PlugInList></servermain:Project>
