$ Date Time State Comment Pressure Bel Pos Batt Volt Batt Amps CTD Temp CTD Sal Raw Press LPF Press LPF Vel Diff Vel Diff 2 Vel Slope of LPF Press. CTD Sample Period LPS331 Press LPS311 Temp SHT21 Humid SHT21 Temp PID SP PID PV PID Y1 PID Y2 PID I PID v PID u PID uCPS PID h FLBB Topt Tphase Rphase NO3 pH OCR GPS Irid Modem $ 13-Dec-2018 01:58:54.823 SM Not Running Reset Controller Status Register Value = 65792 $ 13-Dec-2018 01:58:54.828 SM Not Running File Name = \SD\data\2018-12-13T1-58-53.eng $ 13-Dec-2018 01:58:54.832 SM Not Running Volume Total Size: 7939817472 $ 13-Dec-2018 01:58:54.837 SM Not Running Volume Free Space: 7875264512 $ 13-Dec-2018 01:58:54.841 SM Not Running PlatVel PID K = 80 $ 13-Dec-2018 01:58:54.845 SM Not Running PlatVel PID Ti = 50000 $ 13-Dec-2018 01:58:54.849 SM Not Running PlatVel PID Td = 10 $ 13-Dec-2018 01:58:54.853 SM Not Running PlatVel PID Tf = 10 $ 13-Dec-2018 01:58:54.857 SM Not Running PlatVel PID Tt = 100 $ 13-Dec-2018 01:58:54.861 SM Not Running PlatVel PID B = 1 $ 13-Dec-2018 01:58:54.866 SM Not Running PlatVel PID uLow = -50 $ 13-Dec-2018 01:58:54.870 SM Not Running PlatVel PID uHigh = 50 $ 13-Dec-2018 01:58:54.874 SM Not Running PlatVel PID h = 3 $ 13-Dec-2018 01:58:54.878 SM Not Running Engr Logger Initialized $ 13-Dec-2018 01:58:54.882 SM Not Running Initializing Bluetooth Console $ 13-Dec-2018 01:58:55.886 SM Not Running Initializing GPS and synching time $ 13-Dec-2018 01:58:57.001 SM Not Running Creating Mission $ 13-Dec-2018 01:58:57.104 SM Not Running Maximum number of profiles = 10 $ 13-Dec-2018 01:58:57.208 SM Not Running Mission Timeout = 24:00:00 Mission Start Time: 12/13/2018 01:58:57 $ 13-Dec-2018 01:58:57.310 SM Not Running Recovery mode = True $ 13-Dec-2018 01:58:57.412 SM Not Running Park Sample Period = 00:01:00 $ 13-Dec-2018 01:58:57.516 SM Not Running Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7 $ 13-Dec-2018 01:58:57.620 SM Not Running Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:57.725 SM Not Running Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:57.830 SM Not Running Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:57.934 SM Not Running Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.038 SM Not Running Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.143 SM Not Running Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.247 SM Not Running Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.352 SM Not Running Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.456 SM Not Running Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.561 SM Not Running Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.665 SM Not Running Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.769 SM Not Running Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.874 SM Not Running Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:58.978 SM Not Running Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.083 SM Not Running Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.187 SM Not Running Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.292 SM Not Running Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.396 SM Not Running Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.501 SM Not Running Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.605 SM Not Running Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.709 SM Not Running Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.814 SM Not Running Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:58:59.918 SM Not Running Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:59:00.023 SM Not Running Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:59:00.127 SM Not Running Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:59:00.231 SM Not Running Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:59:00.336 SM Not Running Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.050, 00:00:00, 7 $ 13-Dec-2018 01:59:00.341 SM Not Running Initializing Buoyancy Engine $ 13-Dec-2018 01:59:00.543 SM Not Running Starting valve close $ 13-Dec-2018 01:59:00.548 Init Mission State Entry $ 13-Dec-2018 01:59:00.748 Init Mission Initializing FLBB $ 13-Dec-2018 01:59:05.255 Init Mission Sending FLBB stop command $ 13-Dec-2018 01:59:06.858 Init Mission Sending FLBB pkt command: $pkt 1 $ 13-Dec-2018 01:59:07.962 Init Mission Sending FLBB ave command: $ave 10 $ 13-Dec-2018 01:59:10.067 Init Mission Initializing Iridium Modem $ 13-Dec-2018 01:59:19.586 Init Mission Initializing SBE41 $ 13-Dec-2018 01:59:25.092 Init Mission Sending SBE41 stopProfile $ 13-Dec-2018 01:59:26.097 Init Mission pcutoff=1 $ 13-Dec-2018 01:59:27.102 Init Mission Sending outputPTSyes $ 13-Dec-2018 01:59:28.107 Init Mission Sending tsWait $ 13-Dec-2018 01:59:29.112 Init Mission Sending 11 bin setup commands $ 13-Dec-2018 01:59:35.640 Init Mission Initializing Optode $ 13-Dec-2018 01:59:36.243 Init Mission Sending Optode Wakeup $ 13-Dec-2018 01:59:41.249 Init Mission Initializing Pressure, Temperature, Humidity sensor $ 13-Dec-2018 01:59:41.756 Init Mission Set can pressure resolution to low $ 13-Dec-2018 01:59:41.858 Init Mission Set can pressure active $ 13-Dec-2018 01:59:41.862 Init Mission PTH Message 787.513916 24.516667 53.322357 25.469333 $ 13-Dec-2018 01:59:42.065 Init Mission Initializing MSC $ 13-Dec-2018 01:59:42.667 Init Mission MSC: OUT: INIT $ 13-Dec-2018 01:59:42.770 Init Mission Initializing Radiometer 1 $ 13-Dec-2018 01:59:43.342 Init Mission Powering down OCR504 $ 13-Dec-2018 01:59:48.346 Init Mission Powering up OCR504 $ 13-Dec-2018 01:59:53.351 Init Mission FLBB Message /99/99,99:99:99,695,2293,700,4130,533 $ 13-Dec-2018 01:59:13.582 Init Mission A3LA Message AT&D0 $ 13-Dec-2018 01:59:13.584 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:14.582 Init Mission A3LA Message AT&K0 $ 13-Dec-2018 01:59:14.584 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:15.586 Init Mission A3LA Message AT+SBDD2 $ 13-Dec-2018 01:59:15.588 Init Mission A3LA Message 0 $ 13-Dec-2018 01:59:15.589 Init Mission A3LA Message $ 13-Dec-2018 01:59:15.591 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:16.591 Init Mission A3LA Message AT+GSN $ 13-Dec-2018 01:59:16.600 Init Mission A3LA Message 300125060561320 $ 13-Dec-2018 01:59:16.601 Init Mission A3LA Message $ 13-Dec-2018 01:59:16.603 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:17.988 Init Mission A3LA Message AT+SBDC $ 13-Dec-2018 01:59:17.990 Init Mission A3LA Message 0 $ 13-Dec-2018 01:59:17.991 Init Mission A3LA Message $ 13-Dec-2018 01:59:55.290 Init Mission PTH Message 787.513916 24.558333 53.406281 25.426433 $ 13-Dec-2018 01:59:55.494 Init Mission RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 140.844651 28.775000 112.000000 $ 13-Dec-2018 01:59:55.605 Init Mission Starting valve close $ 13-Dec-2018 01:59:57.610 Init Mission Closed valve isValveOpen = false $ 13-Dec-2018 01:59:57.708 Init Mission Starting valve open $ 13-Dec-2018 01:59:59.810 Init Mission Opened valve isValveOpen = true $ 13-Dec-2018 01:59:59.909 Init Mission Starting valve close $ 13-Dec-2018 02:00:02.011 Init Mission Closed valve isValveOpen = false $ 13-Dec-2018 01:59:17.993 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:18.591 Init Mission A3LA Message ATEn=0 $ 13-Dec-2018 01:59:18.593 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:19.747 Init Mission A3LA Message $ 13-Dec-2018 01:59:19.757 Init Mission A3LA Message 8988169234000597401 $ 13-Dec-2018 01:59:19.758 Init Mission A3LA Message $ 13-Dec-2018 01:59:19.760 Init Mission A3LA Message OK $ 13-Dec-2018 01:59:25.208 Init Mission Unparsed SBE41 Message S>stopprofile $ 13-Dec-2018 01:59:26.211 Init Mission Unparsed SBE41 Message ?cmd S>pcutoff=1 $ 13-Dec-2018 01:59:27.218 Init Mission Unparsed SBE41 Message S>outputpts=y $ 13-Dec-2018 01:59:28.219 Init Mission Unparsed SBE41 Message S>tswait=2 $ 13-Dec-2018 01:59:29.231 Init Mission Unparsed SBE41 Message S>autobinavg=n $ 13-Dec-2018 01:59:29.666 Init Mission Unparsed SBE41 Message S>top_bin_interval=2 $ 13-Dec-2018 01:59:30.157 Init Mission Unparsed SBE41 Message S>top_bin_size=2 $ 13-Dec-2018 01:59:30.675 Init Mission Unparsed SBE41 Message S>top_bin_max=10 $ 13-Dec-2018 02:00:04.006 Init Mission RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 250.000000 28.775000 112.000000 $ 13-Dec-2018 02:00:04.118 Init Mission Starting valve open $ 13-Dec-2018 02:00:04.326 Init Mission Bellows inside limits $ 13-Dec-2018 01:59:31.192 Init Mission Unparsed SBE41 Message S>middle_bin_interval=2 $ 13-Dec-2018 01:59:31.683 Init Mission Unparsed SBE41 Message S>middle_bin_size=2 $ 13-Dec-2018 01:59:32.183 Init Mission Unparsed SBE41 Message S>middle_bin_max=20 $ 13-Dec-2018 01:59:32.693 Init Mission Unparsed SBE41 Message S>bottom_bin_interval=2 $ 13-Dec-2018 01:59:33.184 Init Mission Unparsed SBE41 Message S>bottom_bin_size=2 $ 13-Dec-2018 01:59:33.697 Init Mission Unparsed SBE41 Message S>includetransitionbin=n $ 13-Dec-2018 01:59:34.176 Init Mission Unparsed SBE41 Message S>includenbin=y $ 13-Dec-2018 01:59:37.294 Init Mission Optode Message *,ERROR,SYNTAX ERROR $ 13-Dec-2018 01:59:38.304 Init Mission Optode Message *,ERROR,PROTECTED PROPERTY $ 13-Dec-2018 01:59:39.320 Init Mission Optode Message *,ERROR,PROTECTED PROPERTY $ 13-Dec-2018 02:00:05.587 Init Mission MSC: RX: $ 13-Dec-2018 02:00:05.689 Init Mission MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initializing... $ 13-Dec-2018 02:00:05.694 Init Mission MSC: RX: MBARI Serial Number : 0777 $ 13-Dec-2018 02:00:05.895 Init Mission MSC: RX: CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 $ 13-Dec-2018 02:00:05.998 Init Mission MSC: RX: CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 $ 13-Dec-2018 02:00:06.003 Init Mission Radiometer Message Satlantic OCR-504 Multispectral Radiometer $ 13-Dec-2018 02:00:06.411 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 138.775326 28.775000 112.000000 $ 13-Dec-2018 02:00:07.829 Init Mission Increasing bellows position 139.617793 $ 13-Dec-2018 02:00:10.039 Init Mission Increasing bellows position 139.961377 $ 13-Dec-2018 02:00:12.250 Init Mission Increasing bellows position 140.350670 $ 13-Dec-2018 02:00:14.460 Init Mission Increasing bellows position 140.553400 $ 13-Dec-2018 02:00:16.672 Init Mission Increasing bellows position 140.571296 $ 13-Dec-2018 02:00:18.882 Init Mission Increasing bellows position 140.616819 $ 13-Dec-2018 02:00:21.093 Init Mission Increasing bellows position 140.664518 $ 13-Dec-2018 02:00:23.303 Init Mission Increasing bellows position 140.666135 $ 13-Dec-2018 02:00:25.514 Init Mission Increasing bellows position 140.690573 $ 13-Dec-2018 02:00:27.725 Init Mission Increasing bellows position 140.671261 $ 13-Dec-2018 02:00:30.238 Init Mission Decreasing bellows position 140.701264 $ 13-Dec-2018 02:00:32.448 Init Mission Decreasing bellows position 140.701376 $ 13-Dec-2018 02:00:34.658 Init Mission Decreasing bellows position 140.713088 $ 13-Dec-2018 02:00:36.870 Init Mission Decreasing bellows position 140.707262 $ 13-Dec-2018 02:00:39.080 Init Mission Decreasing bellows position 140.718713 $ 13-Dec-2018 02:00:41.291 Init Mission Decreasing bellows position 140.737571 $ 13-Dec-2018 02:00:43.501 Init Mission Decreasing bellows position 140.735544 $ 13-Dec-2018 02:00:45.712 Init Mission Decreasing bellows position 140.733741 $ 13-Dec-2018 02:00:47.931 Init Mission Decreasing bellows position 140.730314 $ 13-Dec-2018 02:00:50.142 Init Mission Decreasing bellows position 140.725054 $ 13-Dec-2018 02:00:52.151 Init Mission Radiometer Message Copyright (C) 2011, Satlantic Inc. All rights reserved. $ 13-Dec-2018 02:00:52.349 Init Mission Radiometer Message Firmware version: 5.1.0 - SatNet Type B $ 13-Dec-2018 02:00:52.459 Init Mission Radiometer Message Instrument: SATFI4 $ 13-Dec-2018 02:00:52.568 Init Mission Radiometer Message S/N: 0287 $ 13-Dec-2018 02:00:52.578 Init Mission Radiometer Message Reset Source: Power $ 13-Dec-2018 02:00:52.687 Init Mission Radiometer Message Press for command console. $ 13-Dec-2018 02:00:52.797 Init Mission Radiometer Message Initializing system. Please wait... $ 13-Dec-2018 02:00:53.003 Init Mission MSC: RX: CF Card: Size=256614400 Avail=99.09% $ 13-Dec-2018 02:00:53.008 Init Mission MSC: RX: CF2 Power Up (GMT): Tue Jan 31 08:24:53 2012 $ 13-Dec-2018 02:00:53.208 Init Mission MSC: RX: CF2 RTC Time (GMT): Tue Jan 31 08:24:57 2012 $ 13-Dec-2018 02:00:53.215 Init Mission MSC: RX: Adjusted Local Time: Tue Jan 31 00:24:57 2012 $ 13-Dec-2018 02:00:53.415 Init Mission MSC: RX: TZ Offset (GMT - LOCAL) : +8.00 hrs. $ 13-Dec-2018 02:00:53.420 Init Mission MSC: RX: RTC delta (CF2 - DS3234) : +0.00 secs. $ 13-Dec-2018 02:00:53.621 Init Mission MSC: RX: System Batt Voltage = 11.764 $ 13-Dec-2018 02:00:53.723 Init Mission MSC: RX: System Load Current = 2.62e-02 $ 13-Dec-2018 02:00:53.728 Init Mission MSC: RX: Housing Temperature = +23.31C = +73.96F $ 13-Dec-2018 02:00:54.034 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 140.718192 28.775000 112.000000 $ 13-Dec-2018 02:00:54.146 Init Mission MSC: RX: Housing Humidity = 56.3% = 14.1C (DP) $ 13-Dec-2018 02:00:54.251 Init Mission MSC: RX: Power Cycle Count = 157 $ 13-Dec-2018 02:00:54.353 Init Mission MSC: RX: System Reset Count = 161 $ 13-Dec-2018 02:00:54.455 Init Mission MSC: RX: System Error Count = 66 $ 13-Dec-2018 02:00:54.560 Init Mission MSC: RX: Last System Error = -110 $ 13-Dec-2018 02:00:54.662 Init Mission MSC: RX: Last Error Time = Tue Jan 31 02:58:15 2012 $ 13-Dec-2018 02:00:54.765 Init Mission MSC: RX: ISUS Error Count = 1 $ 13-Dec-2018 02:00:54.867 Init Mission MSC: RX: Last ISUS Error = -202 $ 13-Dec-2018 02:00:54.969 Init Mission MSC: RX: Last Error Time = Thu Jan 26 03:13:44 2012 $ 13-Dec-2018 02:00:55.074 Init Mission MSC: RX: DURA Error Count = 0 $ 13-Dec-2018 02:00:55.176 Init Mission MSC: RX: Last DURA Error = 0 $ 13-Dec-2018 02:00:55.181 Init Mission MSC: RX: Last Error Time = Thu Jan 1 00:00:00 1970 $ 13-Dec-2018 02:00:55.381 Init Mission MSC: RX: Fiberlite Odometer = 100:12:10 = 360730 secs $ 13-Dec-2018 02:00:55.386 Init Mission MSC: RX: Fiberlite Cycles = 254 $ 13-Dec-2018 02:00:55.586 Init Mission MSC: RX: Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 $ 13-Dec-2018 02:00:55.690 Init Mission MSC: RX: Zeiss Coef File Found 4 coefs loaded. $ 13-Dec-2018 02:00:55.897 Init Mission PTH Message 788.261475 24.550000 53.551239 25.383533 $ 13-Dec-2018 02:00:56.099 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 140.760161 26.900000 181.000000 $ 13-Dec-2018 02:00:56.210 Init Mission Sending SBE41 ds command $ 13-Dec-2018 02:00:56.314 Init Mission Sending ds command $ 13-Dec-2018 02:00:56.318 Init Mission MSC: RX: Ecoef File Found 256 coefs loaded. $ 13-Dec-2018 02:00:56.527 Init Mission MSC: RX: There are 72 records in the error file! $ 13-Dec-2018 02:00:56.632 Init Mission MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initialized $ 13-Dec-2018 02:00:56.638 Init Mission MSC: RX: Auto Shutdown in 10 hours at: Tue Jan 31 18:24:58 2012 $ 13-Dec-2018 02:00:56.843 Init Mission MSC: RX: Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode $ 13-Dec-2018 02:00:56.850 Init Mission Radiometer Message Autonomous operation enabled. $ 13-Dec-2018 01:59:53.898 Init Mission SBE41 Message 0.43 0.430000 0.000004 0.000000 -0.143333 -0.071667 -0.000000 3.000000 $ 13-Dec-2018 02:00:57.388 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.740544 26.900000 181.000000 $ 13-Dec-2018 02:00:57.501 Init Mission Sending SBE41 ds command $ 13-Dec-2018 02:00:57.806 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.743382 26.900000 181.000000 $ 13-Dec-2018 02:00:58.501 Init Mission Sending SBE41 ds command $ 13-Dec-2018 02:00:56.419 Init Mission Unparsed SBE41 Message S>ds $ 13-Dec-2018 02:00:56.524 Init Mission Unparsed SBE41 Message firmware compilation date: 18 December 2007 09:20 $ 13-Dec-2018 02:00:56.526 Init Mission Unparsed SBE41 Message stop profile when pressure is less than = 1.0 decibars $ 13-Dec-2018 02:00:56.630 Init Mission Unparsed SBE41 Message automatic bin averaging at end of profile disabled $ 13-Dec-2018 02:00:56.631 Init Mission Unparsed SBE41 Message number of samples = 264 $ 13-Dec-2018 02:00:56.631 Init Mission Unparsed SBE41 Message number of bins = 0 $ 13-Dec-2018 02:00:59.512 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.733540 26.900000 181.000000 $ 13-Dec-2018 02:00:59.624 Init Mission Sending SBE41 ds command $ 13-Dec-2018 02:00:56.736 Init Mission Unparsed SBE41 Message top bin interval = 2 $ 13-Dec-2018 02:00:56.736 Init Mission Unparsed SBE41 Message top bin size = 2 $ 13-Dec-2018 02:00:56.737 Init Mission Unparsed SBE41 Message top bin max = 10 $ 13-Dec-2018 02:00:56.841 Init Mission Unparsed SBE41 Message middle bin interval = 2 $ 13-Dec-2018 02:00:56.841 Init Mission Unparsed SBE41 Message middle bin size = 2 $ 13-Dec-2018 02:00:56.842 Init Mission Unparsed SBE41 Message middle bin max = 20 $ 13-Dec-2018 02:00:56.948 Init Mission Unparsed SBE41 Message bottom bin interval = 2 $ 13-Dec-2018 02:00:56.948 Init Mission Unparsed SBE41 Message bottom bin size = 2 $ 13-Dec-2018 02:00:56.949 Init Mission Unparsed SBE41 Message do not include two transition bins $ 13-Dec-2018 02:00:56.950 Init Mission Unparsed SBE41 Message include samples per bin $ 13-Dec-2018 02:00:57.060 Init Mission Unparsed SBE41 Message pumped take sample wait time = 2 sec $ 13-Dec-2018 02:00:57.061 Init Mission Unparsed SBE41 Message real-time output is PTS $ 13-Dec-2018 02:01:01.239 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.733689 26.900000 181.000000 $ 13-Dec-2018 02:01:01.355 Init Mission Sending SBE41 ds command $ 13-Dec-2018 02:01:01.561 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.748188 26.900000 181.000000 $ 13-Dec-2018 02:01:02.356 Init Mission Sending SBE41 dc command $ 13-Dec-2018 02:01:02.459 Init Mission Sending dc command $ 13-Dec-2018 02:01:02.665 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.735365 26.900000 181.000000 $ 13-Dec-2018 02:01:03.356 Init Mission Sending SBE41 dc command $ 13-Dec-2018 02:01:02.565 Init Mission Unparsed SBE41 Message S>dc $ 13-Dec-2018 02:01:02.566 Init Mission Unparsed SBE41 Message temperature: 15-mar-14 $ 13-Dec-2018 02:01:02.593 Init Mission Unparsed SBE41 Message TA0 = 3.536242e-05 $ 13-Dec-2018 02:01:02.629 Init Mission Unparsed SBE41 Message TA1 = 2.674251e-04 $ 13-Dec-2018 02:01:02.776 Init Mission Unparsed SBE41 Message TA2 = -1.901062e-06 $ 13-Dec-2018 02:01:02.776 Init Mission Unparsed SBE41 Message TA3 = 1.365250e-07 $ 13-Dec-2018 02:01:02.777 Init Mission Unparsed SBE41 Message conductivity: 15-mar-14 $ 13-Dec-2018 02:01:02.778 Init Mission Unparsed SBE41 Message G = -9.858232e-01 $ 13-Dec-2018 02:01:02.805 Init Mission Unparsed SBE41 Message H = 1.476071e-01 $ 13-Dec-2018 02:01:02.838 Init Mission Unparsed SBE41 Message I = -3.292498e-04 $ 13-Dec-2018 02:01:02.872 Init Mission Unparsed SBE41 Message J = 4.505543e-05 $ 13-Dec-2018 02:01:02.910 Init Mission Unparsed SBE41 Message CPCOR = -9.570001e-08 $ 13-Dec-2018 02:01:02.948 Init Mission Unparsed SBE41 Message CTCOR = 3.250000e-06 $ 13-Dec-2018 02:01:02.987 Init Mission Unparsed SBE41 Message WBOTC = -3.218098e-07 $ 13-Dec-2018 02:01:03.070 Init Mission Unparsed SBE41 Message pressure S/N = 4004719, range = 2900 psia: 10-mar-14 $ 13-Dec-2018 02:01:05.331 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.726469 26.900000 181.000000 $ 13-Dec-2018 02:01:05.442 Init Mission Sending SBE41 dc command $ 13-Dec-2018 02:01:03.107 Init Mission Unparsed SBE41 Message PA0 = 1.629284e-01 $ 13-Dec-2018 02:01:03.142 Init Mission Unparsed SBE41 Message PA1 = 1.404717e-01 $ 13-Dec-2018 02:01:03.178 Init Mission Unparsed SBE41 Message PA2 = -3.503310e-08 $ 13-Dec-2018 02:01:03.217 Init Mission Unparsed SBE41 Message PTCA0 = 2.758681e+01 $ 13-Dec-2018 02:01:03.256 Init Mission Unparsed SBE41 Message PTCA1 = 2.201518e-02 $ 13-Dec-2018 02:01:03.294 Init Mission Unparsed SBE41 Message PTCA2 = 1.374282e-03 $ 13-Dec-2018 02:01:03.332 Init Mission Unparsed SBE41 Message PTCB0 = 2.510888e+01 $ 13-Dec-2018 02:01:03.458 Init Mission Unparsed SBE41 Message PTCB1 = 1.175000e-03 $ 13-Dec-2018 02:01:03.459 Init Mission Unparsed SBE41 Message PTCB2 = 0.000000e+00 $ 13-Dec-2018 02:01:03.460 Init Mission Unparsed SBE41 Message PTHA0 = -7.442904e+01 $ 13-Dec-2018 02:01:03.578 Init Mission Unparsed SBE41 Message PTHA1 = 4.994783e-02 $ 13-Dec-2018 02:01:03.579 Init Mission Unparsed SBE41 Message PTHA2 = -3.966033e-07 $ 13-Dec-2018 02:01:03.580 Init Mission Unparsed SBE41 Message POFFSET = 0.000000e+00 $ 13-Dec-2018 02:01:07.178 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.744686 26.900000 181.000000 $ 13-Dec-2018 02:01:07.290 Init Mission Sending SBE41 dc command $ 13-Dec-2018 02:01:07.593 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.746675 26.900000 181.000000 $ 13-Dec-2018 02:01:08.492 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.430000 140.757911 26.900000 181.000000 $ 13-Dec-2018 02:01:09.290 Init Mission Sending Optode GetAll $ 13-Dec-2018 02:01:09.294 Init Mission Sending Optode Wakeup $ 13-Dec-2018 02:01:09.264 Init Mission SBE41 Message -0.09 -0.090000 0.000910 0.000011 0.173333 0.015000 -0.000000 3.000000 $ 13-Dec-2018 02:01:10.063 Init Mission Optode Message %!Product Name,4330,1532,Optode Sensor $ 13-Dec-2018 02:01:10.095 Init Mission Optode Message Product Number,4330,1532,4330 $ 13-Dec-2018 02:01:10.127 Init Mission Optode Message Serial Number,4330,1532,1532 $ 13-Dec-2018 02:01:10.152 Init Mission Optode Message SW ID,4330,1532,1940006 $ 13-Dec-2018 02:01:10.182 Init Mission Optode Message SW Version,4330,1532,4,8,1 $ 13-Dec-2018 02:01:10.223 Init Mission Optode Message Node Description,4330,1532,optode 1532 $ 13-Dec-2018 02:01:10.242 Init Mission Optode Message Owner,4330,1532, $ 13-Dec-2018 02:01:10.273 Init Mission Optode Message Salinity[PSU],4330,1532,0.00 $ 13-Dec-2018 02:01:10.349 Init Mission Optode Message PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00 $ 13-Dec-2018 02:01:10.374 Init Mission Optode Message FoilID,4330,1532,1206E $ 13-Dec-2018 02:01:10.593 Init Mission Optode Message FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04 $ 13-Dec-2018 02:01:10.808 Init Mission Optode Message FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00 $ 13-Dec-2018 02:01:10.891 Init Mission Optode Message FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0 $ 13-Dec-2018 02:01:14.693 Init Mission Normal State Exit $ 13-Dec-2018 02:01:14.697 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.090000 140.738912 26.900000 181.000000 $ 13-Dec-2018 02:01:14.915 Init Profile State Entry $ 13-Dec-2018 02:01:14.919 Init Profile Initializing SBE 41 LPF $ 13-Dec-2018 02:01:15.128 Init Profile Sending SBE41 stopProfile $ 13-Dec-2018 02:01:16.138 Init Profile Resetting SBE41 with qsr $ 13-Dec-2018 02:01:16.239 Init Profile Sending qsr command $ 13-Dec-2018 02:01:10.974 Init Profile Optode Message FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0 $ 13-Dec-2018 02:01:11.093 Init Profile Optode Message SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00 $ 13-Dec-2018 02:01:11.141 Init Profile Optode Message ConcCoef,4330,1532,-1.549127E+00,1.068129E+00 $ 13-Dec-2018 02:01:11.179 Init Profile Optode Message NomAirPress[hPa],4330,1532,1013.25 $ 13-Dec-2018 02:01:11.209 Init Profile Optode Message NomAirMix,4330,1532,0.20946 $ 13-Dec-2018 02:01:11.249 Init Profile Optode Message CalDataSat[Deg],4330,1532,31.61,10.06 $ 13-Dec-2018 02:01:11.290 Init Profile Optode Message CalDataAPress[hPa],4330,1532,1002.000 $ 13-Dec-2018 02:01:11.334 Init Profile Optode Message CalDataZero[Deg],4330,1532,61.907,21.413 $ 13-Dec-2018 02:01:11.373 Init Profile Optode Message Mode,4330,1532,Smart Sensor Terminal $ 13-Dec-2018 02:01:11.402 Init Profile Optode Message Enable Sleep,4330,1532,Yes $ 13-Dec-2018 02:01:11.438 Init Profile Optode Message Enable Polled Mode,4330,1532,Yes $ 13-Dec-2018 02:01:11.465 Init Profile Optode Message Enable Text,4330,1532,Yes $ 13-Dec-2018 02:01:11.504 Init Profile Optode Message Enable Decimalformat,4330,1532,Yes $ 13-Dec-2018 02:01:11.552 Init Profile Optode Message Analog TempLimit[Deg.C],4330,1532,-5.00,35.00 $ 13-Dec-2018 02:01:11.601 Init Profile Optode Message Analog ConcLimit[Deg.C],4330,1532,0.00,800.00 $ 13-Dec-2018 02:01:11.649 Init Profile Optode Message Analog SatLimit[Deg.C],4330,1532,0.00,200.00 $ 13-Dec-2018 02:01:20.240 Init Profile Normal State Exit $ 13-Dec-2018 02:01:20.244 Init Profile RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.090000 140.749402 26.900000 181.000000 $ 13-Dec-2018 02:01:20.459 Init Profile ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.5441462 $ 13-Dec-2018 02:01:20.465 Surface Ops Set Bellows State Entry $ 13-Dec-2018 02:01:20.669 Surface Ops Set Bellows Inflating bellows to Surface Ops position = 155.0 at 200000 cps $ 13-Dec-2018 02:01:11.698 Surface Ops Set Bellows Optode Message Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00 $ 13-Dec-2018 02:01:11.741 Surface Ops Set Bellows Optode Message Analog Output,4330,1532,O2Concentration $ 13-Dec-2018 02:01:11.795 Surface Ops Set Bellows Optode Message Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00 $ 13-Dec-2018 02:01:11.845 Surface Ops Set Bellows Optode Message Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00 $ 13-Dec-2018 02:01:11.882 Surface Ops Set Bellows Optode Message Enable AirSaturation,4330,1532,Yes $ 13-Dec-2018 02:01:11.914 Surface Ops Set Bellows Optode Message Enable Rawdata,4330,1532,Yes $ 13-Dec-2018 02:01:11.949 Surface Ops Set Bellows Optode Message Enable Temperature,4330,1532,Yes $ 13-Dec-2018 02:01:11.985 Surface Ops Set Bellows Optode Message Enable HumidityComp,4330,1532,Yes $ 13-Dec-2018 02:01:12.019 Surface Ops Set Bellows Optode Message Enable SVUformula,4330,1532,No $ 13-Dec-2018 02:01:12.050 Surface Ops Set Bellows Optode Message Interval[s],4330,1532,30.000 $ 13-Dec-2018 02:01:12.072 Surface Ops Set Bellows Optode Message Location,4330,1532, $ 13-Dec-2018 02:01:12.123 Surface Ops Set Bellows Optode Message Geographic Position,4330,1532,60.323605,5.37225 $ 13-Dec-2018 02:01:12.153 Surface Ops Set Bellows Optode Message Vertical Position,4330,1532, $ 13-Dec-2018 02:01:12.177 Surface Ops Set Bellows Optode Message Reference,4330,1532, $ 13-Dec-2018 02:01:12.180 Surface Ops Set Bellows Optode Message # $ 13-Dec-2018 02:01:22.874 Surface Ops Set Bellows Normal State Exit $ 13-Dec-2018 02:01:22.878 Surface Ops Set Bellows RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.090000 140.759178 26.900000 181.000000 $ 13-Dec-2018 02:01:23.094 Surface Ops Set Bellows ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.6291211 $ 13-Dec-2018 02:01:23.099 Pre-Mission Delay State Entry $ 13-Dec-2018 02:01:12.262 Pre-Mission Delay SBE41 Message -0.08 -0.080000 -0.090000 0.000000 -0.003333 -0.001667 0.000000 3.000000 $ 13-Dec-2018 02:01:23.633 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 140.765190 26.900000 181.000000 $ 13-Dec-2018 02:01:15.272 Pre-Mission Delay SBE41 Message -0.23 -0.230000 -0.089980 0.000000 0.050000 0.023333 -0.000000 3.000000 $ 13-Dec-2018 02:01:18.342 Pre-Mission Delay SBE41 Message -0.08 -0.080000 -0.090056 -0.000001 -0.050000 0.000000 0.000000 3.000000 $ 13-Dec-2018 02:01:24.553 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 140.754402 26.900000 181.000000 $ 13-Dec-2018 02:01:25.303 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 140.758559 26.900000 181.000000 $ 13-Dec-2018 02:01:21.983 Pre-Mission Delay Unparsed SBE41 Message S> $ 13-Dec-2018 02:01:26.424 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 140.753388 26.900000 181.000000 $ 13-Dec-2018 02:01:24.351 Pre-Mission Delay SBE41 Message -0.01 -0.010000 -0.092319 -0.000026 -0.023333 -0.036667 0.000003 3.000000 $ 13-Dec-2018 02:01:27.427 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.010000 140.732735 26.900000 181.000000 $ 13-Dec-2018 02:01:27.264 Pre-Mission Delay SBE41 Message -0.34 -0.340000 -0.101630 -0.000043 0.110000 0.043333 0.000017 3.000000 $ 13-Dec-2018 02:01:28.427 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.340000 140.758224 26.900000 181.000000 $ 13-Dec-2018 02:01:29.302 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.340000 140.772879 26.900000 181.000000 $ 13-Dec-2018 02:01:30.302 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.340000 140.774041 26.900000 181.000000 $ 13-Dec-2018 02:01:30.262 Pre-Mission Delay SBE41 Message -0.09 -0.090000 -0.116308 0.000244 -0.083333 0.013333 0.000049 3.000000 $ 13-Dec-2018 02:01:31.332 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.090000 140.757635 26.900000 181.000000 $ 13-Dec-2018 02:01:32.302 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.090000 140.773796 26.900000 181.000000 $ 13-Dec-2018 02:01:33.302 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.090000 140.759975 26.900000 181.000000 $ 13-Dec-2018 02:01:33.800 Pre-Mission Delay State Timed Out $ 13-Dec-2018 02:01:33.804 Surface Ops State Entry $ 13-Dec-2018 02:01:33.910 Surface Ops Powering up Iridium Modem $ 13-Dec-2018 02:01:44.001 Surface Ops Starting valve close $ 13-Dec-2018 02:01:44.005 Surface Ops Sending SBDD2 cmd $ 13-Dec-2018 02:01:33.262 Surface Ops SBE41 Message -0.05 -0.050000 -0.124129 0.001143 -0.013333 -0.048333 0.000089 3.000000 $ 13-Dec-2018 02:01:44.540 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 140.756287 26.900000 181.000000 $ 13-Dec-2018 02:01:44.651 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.7276460 $ 13-Dec-2018 02:01:36.263 Surface Ops SBE41 Message -0.08 -0.080000 -0.125067 0.002219 0.010000 -0.001667 0.000128 3.000000 $ 13-Dec-2018 02:01:37.025 Surface Ops A3LA Message $ 13-Dec-2018 02:01:44.990 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:37.027 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:45.205 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:38.026 Surface Ops A3LA Message $ 13-Dec-2018 02:01:45.418 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:38.028 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:45.630 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:39.027 Surface Ops A3LA Message $ 13-Dec-2018 02:01:45.843 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:39.029 Surface Ops A3LA Message 0 $ 13-Dec-2018 02:01:46.057 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->0 <-- $ 13-Dec-2018 02:01:46.264 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 140.767500 26.900000 181.000000 $ 13-Dec-2018 02:01:46.378 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7214939 $ 13-Dec-2018 02:01:39.030 Surface Ops A3LA Message $ 13-Dec-2018 02:01:46.590 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:39.032 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:46.801 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:39.263 Surface Ops SBE41 Message -0.10 -0.100000 -0.133986 0.002748 0.006667 0.008333 0.000176 3.000000 $ 13-Dec-2018 02:01:40.027 Surface Ops A3LA Message $ 13-Dec-2018 02:01:47.139 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:40.036 Surface Ops A3LA Message 300125060561320 $ 13-Dec-2018 02:01:47.352 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->300125060561320 <-- $ 13-Dec-2018 02:01:40.038 Surface Ops A3LA Message $ 13-Dec-2018 02:01:47.564 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:40.040 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:47.775 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:41.028 Surface Ops A3LA Message $ 13-Dec-2018 02:01:47.992 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:41.029 Surface Ops A3LA Message 0 $ 13-Dec-2018 02:01:48.204 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->0 <-- $ 13-Dec-2018 02:01:41.030 Surface Ops A3LA Message $ 13-Dec-2018 02:01:48.417 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:41.033 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:48.629 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:42.029 Surface Ops A3LA Message $ 13-Dec-2018 02:01:48.841 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:42.031 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:49.056 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:42.262 Surface Ops SBE41 Message -0.07 -0.070000 -0.142821 0.002913 -0.010000 -0.001667 0.000231 3.000000 $ 13-Dec-2018 02:01:49.388 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 140.768103 26.900000 181.000000 $ 13-Dec-2018 02:01:49.501 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1170731 $ 13-Dec-2018 02:01:43.029 Surface Ops A3LA Message $ 13-Dec-2018 02:01:49.713 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:43.040 Surface Ops A3LA Message 8988169234000597401 $ 13-Dec-2018 02:01:49.947 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->8988169234000597401 <-- $ 13-Dec-2018 02:01:43.041 Surface Ops A3LA Message $ 13-Dec-2018 02:01:50.159 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:43.043 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:50.372 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:44.211 Surface Ops A3LA Message $ 13-Dec-2018 02:01:50.584 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:44.211 Surface Ops A3LA Message 0 $ 13-Dec-2018 02:01:50.795 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->0 <-- $ 13-Dec-2018 02:01:44.212 Surface Ops A3LA Message $ 13-Dec-2018 02:01:51.012 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 13-Dec-2018 02:01:44.212 Surface Ops A3LA Message OK $ 13-Dec-2018 02:01:51.224 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 13-Dec-2018 02:01:45.521 Surface Ops SBE41 Message -0.78 -0.780000 -0.128524 0.002990 0.236667 0.113333 0.000266 3.000000 $ 13-Dec-2018 02:01:48.520 Surface Ops SBE41 Message 0.40 0.400000 -0.101665 0.002195 -0.393333 -0.078333 0.000265 3.000000 $ 13-Dec-2018 02:01:51.682 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.400000 140.759401 26.900000 181.000000 $ 13-Dec-2018 02:01:51.793 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.2871170 $ 13-Dec-2018 02:01:51.577 Surface Ops SBE41 Message -0.31 -0.310000 -0.099632 0.000040 0.236667 -0.078333 0.000260 3.000000 $ 13-Dec-2018 02:01:52.129 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.310000 140.754819 26.900000 181.000000 $ 13-Dec-2018 02:01:52.899 Surface Ops Processing Console Command: $go $ 13-Dec-2018 02:01:53.204 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.310000 140.763856 26.900000 181.000000 $ 13-Dec-2018 02:01:54.100 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.310000 140.783273 26.900000 181.000000 $ 13-Dec-2018 02:01:54.382 Surface Ops SBE41 Message -0.07 -0.070000 -0.141741 -0.002286 -0.080000 0.078333 0.000307 3.000000 $ 13-Dec-2018 02:01:55.131 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 140.780665 26.900000 181.000000 $ 13-Dec-2018 02:02:37.970 Surface Ops Powering up 4330 Optode $ 13-Dec-2018 02:02:39.478 Surface Ops Sending Optode Wakeup $ 13-Dec-2018 02:02:43.485 Surface Ops Powering up OCR504 $ 13-Dec-2018 02:02:43.587 Surface Ops Closing old engr log file: \SD\data\2018-12-13T1-58-53.eng