$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	13-Dec-2018	20:45:28.880	SM Not Running	Reset Controller Status Register Value = 65792

$	13-Dec-2018	20:45:28.885	SM Not Running	File Name = \SD\data\2018-12-13T20-45-27.eng

$	13-Dec-2018	20:45:28.889	SM Not Running	Volume Total Size:     7939817472

$	13-Dec-2018	20:45:28.894	SM Not Running	Volume Free Space:     7874543616

$	13-Dec-2018	20:45:28.898	SM Not Running	PlatVel PID K = 80

$	13-Dec-2018	20:45:28.902	SM Not Running	PlatVel PID Ti = 50000

$	13-Dec-2018	20:45:28.906	SM Not Running	PlatVel PID Td = 10

$	13-Dec-2018	20:45:28.910	SM Not Running	PlatVel PID Tf = 10

$	13-Dec-2018	20:45:28.914	SM Not Running	PlatVel PID Tt = 100

$	13-Dec-2018	20:45:28.918	SM Not Running	PlatVel PID B = 1

$	13-Dec-2018	20:45:28.923	SM Not Running	PlatVel PID uLow = -50

$	13-Dec-2018	20:45:28.927	SM Not Running	PlatVel PID uHigh = 50

$	13-Dec-2018	20:45:28.931	SM Not Running	PlatVel PID h = 3

$	13-Dec-2018	20:45:28.935	SM Not Running	Engr Logger Initialized

$	13-Dec-2018	20:45:29.852	SM Not Running	Initializing Bluetooth Console

$	13-Dec-2018	20:45:30.857	SM Not Running	Initializing GPS and synching time

$	13-Dec-2018	20:45:33.001	SM Not Running	Creating Mission

$	13-Dec-2018	20:45:33.104	SM Not Running	Maximum number of profiles = 10

$	13-Dec-2018	20:45:33.208	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 12/13/2018 20:45:33

$	13-Dec-2018	20:45:33.313	SM Not Running	Recovery mode = True

$	13-Dec-2018	20:45:33.419	SM Not Running	Park Sample Period = 00:01:00

$	13-Dec-2018	20:45:33.525	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	13-Dec-2018	20:45:33.632	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:33.739	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:33.845	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:33.952	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.060	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.167	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.273	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.380	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.487	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.595	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.701	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.809	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:34.916	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.023	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.130	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.237	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.344	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.451	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.562	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.668	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.775	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.882	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:35.990	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:36.097	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:36.208	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:36.315	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:36.423	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.050, 00:00:00, 7

$	13-Dec-2018	20:45:36.429	SM Not Running	Initializing Buoyancy Engine

$	13-Dec-2018	20:45:36.630	SM Not Running	Starting valve close

$	13-Dec-2018	20:45:36.635	Init Mission	State Entry

$	13-Dec-2018	20:45:36.736	Init Mission	Initializing FLBB

$	13-Dec-2018	20:45:41.439	Init Mission	Sending FLBB stop command

$	13-Dec-2018	20:45:42.945	Init Mission	Sending FLBB pkt command: $pkt 1  

$	13-Dec-2018	20:45:44.050	Init Mission	Sending FLBB ave command: $ave 10  

$	13-Dec-2018	20:45:46.056	Init Mission	Initializing Iridium Modem

$	13-Dec-2018	20:45:55.660	Init Mission	Initializing SBE41

$	13-Dec-2018	20:46:01.173	Init Mission	Sending SBE41 stopProfile

$	13-Dec-2018	20:46:02.178	Init Mission	pcutoff=1 

$	13-Dec-2018	20:46:03.183	Init Mission	Sending outputPTSyes

$	13-Dec-2018	20:46:04.188	Init Mission	Sending tsWait

$	13-Dec-2018	20:46:05.193	Init Mission	Sending 11 bin setup commands

$	13-Dec-2018	20:46:11.799	Init Mission	Initializing Optode

$	13-Dec-2018	20:46:12.402	Init Mission	Sending Optode Wakeup

$	13-Dec-2018	20:46:17.408	Init Mission	Initializing Pressure, Temperature, Humidity sensor

$	13-Dec-2018	20:46:17.916	Init Mission	Set can pressure resolution to low

$	13-Dec-2018	20:46:18.018	Init Mission	Set can pressure active

$	13-Dec-2018	20:46:18.022	Init Mission	PTH Message														781.665039	23.400000	52.322906	24.278848																			

$	13-Dec-2018	20:46:18.321	Init Mission	Initializing MSC

$	13-Dec-2018	20:46:18.825	Init Mission	MSC: OUT: INIT

$	13-Dec-2018	20:46:18.928	Init Mission	Initializing Radiometer 1

$	13-Dec-2018	20:46:19.440	Init Mission	Powering down OCR504

$	13-Dec-2018	20:46:24.444	Init Mission	Powering up OCR504

$	13-Dec-2018	20:45:49.663	Init Mission	A3LA Message																																			AT&D0   	

$	13-Dec-2018	20:45:49.665	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:45:50.663	Init Mission	A3LA Message																																			AT&K0   	

$	13-Dec-2018	20:45:50.665	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:45:51.667	Init Mission	A3LA Message																																			AT+SBDD2   	

$	13-Dec-2018	20:45:51.668	Init Mission	A3LA Message																																			0  	

$	13-Dec-2018	20:45:51.669	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:45:51.671	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:45:52.672	Init Mission	A3LA Message																																			AT+GSN    	

$	13-Dec-2018	20:45:52.681	Init Mission	A3LA Message																																			300125060561320  	

$	13-Dec-2018	20:45:52.682	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:45:52.684	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:45:54.000	Init Mission	A3LA Message																																			AT+SBDC   	

$	13-Dec-2018	20:45:54.002	Init Mission	A3LA Message																																			0  	

$	13-Dec-2018	20:45:54.003	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:45:54.005	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:46:31.386	Init Mission	PTH Message														781.665039	23.058333	52.406830	24.257397																			

$	13-Dec-2018	20:46:31.589	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	31.875000	102.500000																																

$	13-Dec-2018	20:46:31.700	Init Mission	Starting valve close

$	13-Dec-2018	20:46:33.704	Init Mission	Closed valve isValveOpen = false

$	13-Dec-2018	20:46:33.802	Init Mission	Starting valve open

$	13-Dec-2018	20:46:35.904	Init Mission	Opened valve isValveOpen = true

$	13-Dec-2018	20:46:36.002	Init Mission	Starting valve close

$	13-Dec-2018	20:46:38.105	Init Mission	Closed valve isValveOpen = false

$	13-Dec-2018	20:45:54.680	Init Mission	A3LA Message																																			ATEn=0   	

$	13-Dec-2018	20:45:54.682	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:45:55.768	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:45:55.768	Init Mission	A3LA Message																																			8988169234000597401  	

$	13-Dec-2018	20:45:55.769	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:45:55.769	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:46:01.289	Init Mission	Unparsed SBE41 Message						S>stopprofile  																														

$	13-Dec-2018	20:46:02.292	Init Mission	Unparsed SBE41 Message						?cmd S>pcutoff=1  																														

$	13-Dec-2018	20:46:03.299	Init Mission	Unparsed SBE41 Message						S>outputpts=y  																														

$	13-Dec-2018	20:46:04.300	Init Mission	Unparsed SBE41 Message						S>tswait=2  																														

$	13-Dec-2018	20:46:05.329	Init Mission	Unparsed SBE41 Message						S>autobinavg=n  																														

$	13-Dec-2018	20:46:05.844	Init Mission	Unparsed SBE41 Message						S>top_bin_interval=2  																														

$	13-Dec-2018	20:46:06.334	Init Mission	Unparsed SBE41 Message						S>top_bin_size=2  																														

$	13-Dec-2018	20:46:06.835	Init Mission	Unparsed SBE41 Message						S>top_bin_max=10  																														

$	13-Dec-2018	20:46:07.351	Init Mission	Unparsed SBE41 Message						S>middle_bin_interval=2  																														

$	13-Dec-2018	20:46:40.106	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	31.875000	102.500000																																

$	13-Dec-2018	20:46:40.217	Init Mission	Starting valve open

$	13-Dec-2018	20:46:40.425	Init Mission	Bellows inside limits

$	13-Dec-2018	20:46:07.842	Init Mission	Unparsed SBE41 Message						S>middle_bin_size=2  																														

$	13-Dec-2018	20:46:08.343	Init Mission	Unparsed SBE41 Message						S>middle_bin_max=20  																														

$	13-Dec-2018	20:46:08.852	Init Mission	Unparsed SBE41 Message						S>bottom_bin_interval=2  																														

$	13-Dec-2018	20:46:09.343	Init Mission	Unparsed SBE41 Message						S>bottom_bin_size=2  																														

$	13-Dec-2018	20:46:09.856	Init Mission	Unparsed SBE41 Message						S>includetransitionbin=n  																														

$	13-Dec-2018	20:46:10.335	Init Mission	Unparsed SBE41 Message						S>includenbin=y  																														

$	13-Dec-2018	20:46:13.437	Init Mission	Optode Message																												!#  								

$	13-Dec-2018	20:46:14.443	Init Mission	Optode Message																												#  								

$	13-Dec-2018	20:46:15.450	Init Mission	Optode Message																												#  								

$	13-Dec-2018	20:46:41.592	Init Mission	MSC: RX: 

$	13-Dec-2018	20:46:41.596	Init Mission	MSC: RX: 

$	13-Dec-2018	20:46:41.795	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	13-Dec-2018	20:46:41.898	Init Mission	MSC: RX:   MBARI Serial Number : 0777 

$	13-Dec-2018	20:46:42.000	Init Mission	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	13-Dec-2018	20:46:42.006	Init Mission	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	13-Dec-2018	20:46:42.116	Init Mission	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	13-Dec-2018	20:46:42.426	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	137.597702	31.875000	102.500000																																

$	13-Dec-2018	20:46:43.841	Init Mission	Increasing bellows position		138.391063																																		

$	13-Dec-2018	20:46:46.053	Init Mission	Increasing bellows position		138.723686																																		

$	13-Dec-2018	20:46:48.263	Init Mission	Increasing bellows position		139.106058																																		

$	13-Dec-2018	20:46:50.474	Init Mission	Increasing bellows position		139.387503																																		

$	13-Dec-2018	20:46:52.685	Init Mission	Increasing bellows position		139.528684																																		

$	13-Dec-2018	20:46:54.896	Init Mission	Increasing bellows position		139.529891																																		

$	13-Dec-2018	20:46:57.107	Init Mission	Increasing bellows position		139.534086																																		

$	13-Dec-2018	20:46:59.317	Init Mission	Increasing bellows position		139.541917																																		

$	13-Dec-2018	20:47:01.528	Init Mission	Increasing bellows position		139.571100																																		

$	13-Dec-2018	20:47:03.738	Init Mission	Increasing bellows position		139.566690																																		

$	13-Dec-2018	20:47:06.251	Init Mission	Decreasing bellows position		139.596999																																		

$	13-Dec-2018	20:47:08.461	Init Mission	Decreasing bellows position		139.611714																																		

$	13-Dec-2018	20:47:10.672	Init Mission	Decreasing bellows position		139.617048																																		

$	13-Dec-2018	20:47:12.883	Init Mission	Decreasing bellows position		139.583312																																		

$	13-Dec-2018	20:47:15.094	Init Mission	Decreasing bellows position		139.481097																																		

$	13-Dec-2018	20:47:17.305	Init Mission	Decreasing bellows position		139.461219																																		

$	13-Dec-2018	20:47:19.515	Init Mission	Decreasing bellows position		139.355883																																		

$	13-Dec-2018	20:47:21.726	Init Mission	Decreasing bellows position		139.354512																																		

$	13-Dec-2018	20:47:23.944	Init Mission	Decreasing bellows position		139.263973																																		

$	13-Dec-2018	20:47:26.155	Init Mission	Decreasing bellows position		139.226601																																		

$	13-Dec-2018	20:47:28.166	Init Mission	Radiometer Message																																	Firmware version: 5.1.0 - SatNet Type B 			

$	13-Dec-2018	20:47:28.264	Init Mission	Radiometer Message																																	Instrument: SATFI4 			

$	13-Dec-2018	20:47:28.372	Init Mission	Radiometer Message																																	S/N: 0287 			

$	13-Dec-2018	20:47:28.482	Init Mission	Radiometer Message																																	Reset Source: Power 			

$	13-Dec-2018	20:47:28.591	Init Mission	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	13-Dec-2018	20:47:28.796	Init Mission	Radiometer Message																																	Initializing system. Please wait... 			

$	13-Dec-2018	20:47:28.808	Init Mission	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	13-Dec-2018	20:47:29.009	Init Mission	MSC: RX:   CF Card: Size=256614400 Avail=99.09% 

$	13-Dec-2018	20:47:29.112	Init Mission	MSC: RX:   CF2 Power Up  (GMT): Wed Feb  1 03:11:31 2012 

$	13-Dec-2018	20:47:29.215	Init Mission	MSC: RX:   CF2 RTC Time  (GMT): Wed Feb  1 03:11:35 2012 

$	13-Dec-2018	20:47:29.220	Init Mission	MSC: RX:   Adjusted Local Time: Tue Jan 31 19:11:35 2012 

$	13-Dec-2018	20:47:29.420	Init Mission	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	13-Dec-2018	20:47:29.427	Init Mission	MSC: RX:   RTC delta (CF2 - DS3234) : -1.00 secs. 

$	13-Dec-2018	20:47:29.627	Init Mission	MSC: RX:   System Batt Voltage = 11.764 

$	13-Dec-2018	20:47:29.729	Init Mission	MSC: RX:   System Load Current = 2.62e-02 

$	13-Dec-2018	20:47:29.832	Init Mission	MSC: RX:   Housing Temperature = +22.19C = +71.95F 

$	13-Dec-2018	20:47:30.039	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	139.131382	31.875000	102.500000																																

$	13-Dec-2018	20:47:30.154	Init Mission	MSC: RX:   Housing    Humidity =  55.1%  =  12.8C (DP) 

$	13-Dec-2018	20:47:30.160	Init Mission	MSC: RX:   Power Cycle   Count = 161 

$	13-Dec-2018	20:47:30.262	Init Mission	MSC: RX:   System Reset  Count = 165 

$	13-Dec-2018	20:47:30.461	Init Mission	MSC: RX:   System Error  Count = 66 

$	13-Dec-2018	20:47:30.565	Init Mission	MSC: RX:   Last System   Error = -110 

$	13-Dec-2018	20:47:30.571	Init Mission	MSC: RX:   Last Error     Time = Tue Jan 31 02:58:15 2012 

$	13-Dec-2018	20:47:30.771	Init Mission	MSC: RX:   ISUS Error    Count = 1 

$	13-Dec-2018	20:47:30.873	Init Mission	MSC: RX:   Last ISUS     Error = -202 

$	13-Dec-2018	20:47:30.975	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	13-Dec-2018	20:47:31.078	Init Mission	MSC: RX:   DURA Error    Count = 0 

$	13-Dec-2018	20:47:31.180	Init Mission	MSC: RX:   Last DURA     Error = 0 

$	13-Dec-2018	20:47:31.187	Init Mission	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	13-Dec-2018	20:47:31.387	Init Mission	MSC: RX:   Fiberlite  Odometer = 100:12:10 = 360730 secs 

$	13-Dec-2018	20:47:31.490	Init Mission	MSC: RX:   Fiberlite    Cycles = 254 

$	13-Dec-2018	20:47:31.592	Init Mission	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	13-Dec-2018	20:47:31.695	Init Mission	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	13-Dec-2018	20:47:32.001	Init Mission	PTH Message														782.041748	23.100000	52.406830	24.268123																			

$	13-Dec-2018	20:47:32.202	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	139.077924	31.800000	163.500000																																

$	13-Dec-2018	20:47:32.314	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:47:32.318	Init Mission	Sending ds command

$	13-Dec-2018	20:47:32.523	Init Mission	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	13-Dec-2018	20:47:32.630	Init Mission	MSC: RX:   There are 72 records in the error file! 

$	13-Dec-2018	20:47:32.636	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	13-Dec-2018	20:47:32.841	Init Mission	MSC: RX:   Auto Shutdown in 10 hours at: Wed Feb  1 13:11:36 2012 

$	13-Dec-2018	20:47:32.944	Init Mission	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	13-Dec-2018	20:47:33.048	Init Mission	Radiometer Message																																	Autonomous operation enabled. 			

$	13-Dec-2018	20:46:29.996	Init Mission	SBE41 Message						    0.10  	0.100000	0.000001	0.000000	-0.033333	-0.016667	-0.000000	3.000000																							

$	13-Dec-2018	20:47:33.491	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.068730	31.800000	163.500000																																

$	13-Dec-2018	20:47:33.603	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:47:33.910	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.063232	31.800000	163.500000																																

$	13-Dec-2018	20:47:34.603	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:47:32.520	Init Mission	Unparsed SBE41 Message						S>ds  																														

$	13-Dec-2018	20:47:32.628	Init Mission	Unparsed SBE41 Message						firmware compilation date: 18 December 2007 09:20  																														

$	13-Dec-2018	20:47:32.629	Init Mission	Unparsed SBE41 Message						stop profile when pressure is less than = 1.0 decibars  																														

$	13-Dec-2018	20:47:32.734	Init Mission	Unparsed SBE41 Message						automatic bin averaging at end of profile disabled  																														

$	13-Dec-2018	20:47:32.735	Init Mission	Unparsed SBE41 Message						number of samples = 264  																														

$	13-Dec-2018	20:47:32.735	Init Mission	Unparsed SBE41 Message						number of bins = 0  																														

$	13-Dec-2018	20:47:35.517	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.054887	31.800000	163.500000																																

$	13-Dec-2018	20:47:35.628	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:47:32.839	Init Mission	Unparsed SBE41 Message						top bin interval = 2  																														

$	13-Dec-2018	20:47:32.839	Init Mission	Unparsed SBE41 Message						top bin size = 2  																														

$	13-Dec-2018	20:47:32.840	Init Mission	Unparsed SBE41 Message						top bin max = 10  																														

$	13-Dec-2018	20:47:32.944	Init Mission	Unparsed SBE41 Message						middle bin interval = 2  																														

$	13-Dec-2018	20:47:33.048	Init Mission	Unparsed SBE41 Message						middle bin size = 2  																														

$	13-Dec-2018	20:47:33.159	Init Mission	Unparsed SBE41 Message						middle bin max = 20  																														

$	13-Dec-2018	20:47:33.160	Init Mission	Unparsed SBE41 Message						bottom bin interval = 2  																														

$	13-Dec-2018	20:47:33.180	Init Mission	Unparsed SBE41 Message						bottom bin size = 2  																														

$	13-Dec-2018	20:47:33.181	Init Mission	Unparsed SBE41 Message						do not include two transition bins  																														

$	13-Dec-2018	20:47:33.181	Init Mission	Unparsed SBE41 Message						include samples per bin  																														

$	13-Dec-2018	20:47:33.182	Init Mission	Unparsed SBE41 Message						pumped take sample wait time = 2 sec  																														

$	13-Dec-2018	20:47:33.183	Init Mission	Unparsed SBE41 Message						real-time output is PTS  																														

$	13-Dec-2018	20:47:37.244	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.055900	31.800000	163.500000																																

$	13-Dec-2018	20:47:37.360	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:47:37.566	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.072947	31.800000	163.500000																																

$	13-Dec-2018	20:47:38.361	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:47:38.365	Init Mission	Sending dc command

$	13-Dec-2018	20:47:38.772	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.076091	31.800000	163.500000																																

$	13-Dec-2018	20:47:39.360	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:47:38.568	Init Mission	Unparsed SBE41 Message						S>dc  																														

$	13-Dec-2018	20:47:38.569	Init Mission	Unparsed SBE41 Message						temperature:  15-mar-14  																														

$	13-Dec-2018	20:47:38.596	Init Mission	Unparsed SBE41 Message						    TA0 =  3.536242e-05  																														

$	13-Dec-2018	20:47:38.632	Init Mission	Unparsed SBE41 Message						    TA1 =  2.674251e-04  																														

$	13-Dec-2018	20:47:38.668	Init Mission	Unparsed SBE41 Message						    TA2 = -1.901062e-06  																														

$	13-Dec-2018	20:47:38.704	Init Mission	Unparsed SBE41 Message						    TA3 =  1.365250e-07  																														

$	13-Dec-2018	20:47:38.739	Init Mission	Unparsed SBE41 Message						conductivity:  15-mar-14  																														

$	13-Dec-2018	20:47:38.884	Init Mission	Unparsed SBE41 Message						    G = -9.858232e-01  																														

$	13-Dec-2018	20:47:38.884	Init Mission	Unparsed SBE41 Message						    H =  1.476071e-01  																														

$	13-Dec-2018	20:47:38.885	Init Mission	Unparsed SBE41 Message						    I = -3.292498e-04  																														

$	13-Dec-2018	20:47:38.886	Init Mission	Unparsed SBE41 Message						    J =  4.505543e-05  																														

$	13-Dec-2018	20:47:38.913	Init Mission	Unparsed SBE41 Message						    CPCOR = -9.570001e-08  																														

$	13-Dec-2018	20:47:38.951	Init Mission	Unparsed SBE41 Message						    CTCOR =  3.250000e-06  																														

$	13-Dec-2018	20:47:38.990	Init Mission	Unparsed SBE41 Message						    WBOTC = -3.218098e-07  																														

$	13-Dec-2018	20:47:39.072	Init Mission	Unparsed SBE41 Message						pressure S/N = 4004719, range = 2900 psia:  10-mar-14  																														

$	13-Dec-2018	20:47:41.433	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.065206	31.800000	163.500000																																

$	13-Dec-2018	20:47:41.544	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:47:39.109	Init Mission	Unparsed SBE41 Message						    PA0 =  1.629284e-01  																														

$	13-Dec-2018	20:47:39.145	Init Mission	Unparsed SBE41 Message						    PA1 =  1.404717e-01  																														

$	13-Dec-2018	20:47:39.180	Init Mission	Unparsed SBE41 Message						    PA2 = -3.503310e-08  																														

$	13-Dec-2018	20:47:39.220	Init Mission	Unparsed SBE41 Message						    PTCA0 =  2.758681e+01  																														

$	13-Dec-2018	20:47:39.258	Init Mission	Unparsed SBE41 Message						    PTCA1 =  2.201518e-02  																														

$	13-Dec-2018	20:47:39.296	Init Mission	Unparsed SBE41 Message						    PTCA2 =  1.374282e-03  																														

$	13-Dec-2018	20:47:39.335	Init Mission	Unparsed SBE41 Message						    PTCB0 =  2.510888e+01  																														

$	13-Dec-2018	20:47:39.462	Init Mission	Unparsed SBE41 Message						    PTCB1 =  1.175000e-03  																														

$	13-Dec-2018	20:47:39.463	Init Mission	Unparsed SBE41 Message						    PTCB2 =  0.000000e+00  																														

$	13-Dec-2018	20:47:39.464	Init Mission	Unparsed SBE41 Message						    PTHA0 = -7.442904e+01  																														

$	13-Dec-2018	20:47:39.583	Init Mission	Unparsed SBE41 Message						    PTHA1 =  4.994783e-02  																														

$	13-Dec-2018	20:47:39.584	Init Mission	Unparsed SBE41 Message						    PTHA2 = -3.966033e-07  																														

$	13-Dec-2018	20:47:39.585	Init Mission	Unparsed SBE41 Message						    POFFSET =  0.000000e+00  																														

$	13-Dec-2018	20:47:43.279	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.068469	31.800000	163.500000																																

$	13-Dec-2018	20:47:43.391	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:47:43.598	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.075525	31.800000	163.500000																																

$	13-Dec-2018	20:47:44.593	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.100000	139.065728	31.800000	163.500000																																

$	13-Dec-2018	20:47:45.392	Init Mission	Sending Optode GetAll

$	13-Dec-2018	20:47:45.396	Init Mission	Sending Optode Wakeup

$	13-Dec-2018	20:47:45.364	Init Mission	SBE41 Message						   -0.12  	-0.120000	0.000211	0.000002	0.073333	0.020000	-0.000000	3.000000																							

$	13-Dec-2018	20:47:46.165	Init Mission	Optode Message																												%!Product Name,4330,1532,Optode Sensor  								

$	13-Dec-2018	20:47:46.198	Init Mission	Optode Message																												Product Number,4330,1532,4330  								

$	13-Dec-2018	20:47:46.229	Init Mission	Optode Message																												Serial Number,4330,1532,1532  								

$	13-Dec-2018	20:47:46.255	Init Mission	Optode Message																												SW ID,4330,1532,1940006  								

$	13-Dec-2018	20:47:46.284	Init Mission	Optode Message																												SW Version,4330,1532,4,8,1  								

$	13-Dec-2018	20:47:46.325	Init Mission	Optode Message																												Node Description,4330,1532,optode 1532  								

$	13-Dec-2018	20:47:46.344	Init Mission	Optode Message																												Owner,4330,1532,  								

$	13-Dec-2018	20:47:46.375	Init Mission	Optode Message																												Salinity[PSU],4330,1532,0.00  								

$	13-Dec-2018	20:47:46.451	Init Mission	Optode Message																												PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	20:47:46.476	Init Mission	Optode Message																												FoilID,4330,1532,1206E  								

$	13-Dec-2018	20:47:46.695	Init Mission	Optode Message																												FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04  								

$	13-Dec-2018	20:47:46.911	Init Mission	Optode Message																												FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	20:47:46.993	Init Mission	Optode Message																												FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0  								

$	13-Dec-2018	20:47:50.898	Init Mission	Normal State Exit

$	13-Dec-2018	20:47:51.002	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.061153	31.800000	163.500000																																

$	13-Dec-2018	20:47:51.118	Init Profile	State Entry

$	13-Dec-2018	20:47:51.224	Init Profile	Initializing SBE 41 LPF

$	13-Dec-2018	20:47:51.332	Init Profile	Sending SBE41 stopProfile

$	13-Dec-2018	20:47:52.336	Init Profile	Resetting SBE41 with qsr

$	13-Dec-2018	20:47:52.340	Init Profile	Sending qsr command

$	13-Dec-2018	20:47:47.076	Init Profile	Optode Message																												FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0  								

$	13-Dec-2018	20:47:47.195	Init Profile	Optode Message																												SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	20:47:47.243	Init Profile	Optode Message																												ConcCoef,4330,1532,-1.549127E+00,1.068129E+00  								

$	13-Dec-2018	20:47:47.281	Init Profile	Optode Message																												NomAirPress[hPa],4330,1532,1013.25  								

$	13-Dec-2018	20:47:47.311	Init Profile	Optode Message																												NomAirMix,4330,1532,0.20946  								

$	13-Dec-2018	20:47:47.351	Init Profile	Optode Message																												CalDataSat[Deg],4330,1532,31.61,10.06  								

$	13-Dec-2018	20:47:47.393	Init Profile	Optode Message																												CalDataAPress[hPa],4330,1532,1002.000  								

$	13-Dec-2018	20:47:47.436	Init Profile	Optode Message																												CalDataZero[Deg],4330,1532,61.907,21.413  								

$	13-Dec-2018	20:47:47.475	Init Profile	Optode Message																												Mode,4330,1532,Smart Sensor Terminal  								

$	13-Dec-2018	20:47:47.505	Init Profile	Optode Message																												Enable Sleep,4330,1532,Yes  								

$	13-Dec-2018	20:47:47.540	Init Profile	Optode Message																												Enable Polled Mode,4330,1532,Yes  								

$	13-Dec-2018	20:47:47.566	Init Profile	Optode Message																												Enable Text,4330,1532,No  								

$	13-Dec-2018	20:47:47.604	Init Profile	Optode Message																												Enable Decimalformat,4330,1532,Yes  								

$	13-Dec-2018	20:47:47.653	Init Profile	Optode Message																												Analog TempLimit[Deg.C],4330,1532,-5.00,35.00  								

$	13-Dec-2018	20:47:47.702	Init Profile	Optode Message																												Analog ConcLimit[Deg.C],4330,1532,0.00,800.00  								

$	13-Dec-2018	20:47:47.750	Init Profile	Optode Message																												Analog SatLimit[Deg.C],4330,1532,0.00,200.00  								

$	13-Dec-2018	20:47:56.564	Init Profile	Normal State Exit

$	13-Dec-2018	20:47:56.568	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.074378	31.800000	163.500000																																

$	13-Dec-2018	20:47:56.782	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.6629974

$	13-Dec-2018	20:47:56.788	Surface Ops Set Bellows	State Entry

$	13-Dec-2018	20:47:56.994	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	13-Dec-2018	20:47:47.799	Surface Ops Set Bellows	Optode Message																												Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00  								

$	13-Dec-2018	20:47:47.842	Surface Ops Set Bellows	Optode Message																												Analog Output,4330,1532,O2Concentration  								

$	13-Dec-2018	20:47:47.896	Surface Ops Set Bellows	Optode Message																												Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	13-Dec-2018	20:47:47.946	Surface Ops Set Bellows	Optode Message																												Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	13-Dec-2018	20:47:47.982	Surface Ops Set Bellows	Optode Message																												Enable AirSaturation,4330,1532,No  								

$	13-Dec-2018	20:47:48.014	Surface Ops Set Bellows	Optode Message																												Enable Rawdata,4330,1532,Yes  								

$	13-Dec-2018	20:47:48.049	Surface Ops Set Bellows	Optode Message																												Enable Temperature,4330,1532,Yes  								

$	13-Dec-2018	20:47:48.085	Surface Ops Set Bellows	Optode Message																												Enable HumidityComp,4330,1532,Yes  								

$	13-Dec-2018	20:47:48.119	Surface Ops Set Bellows	Optode Message																												Enable SVUformula,4330,1532,No  								

$	13-Dec-2018	20:47:48.149	Surface Ops Set Bellows	Optode Message																												Interval[s],4330,1532,30.000  								

$	13-Dec-2018	20:47:48.172	Surface Ops Set Bellows	Optode Message																												Location,4330,1532,  								

$	13-Dec-2018	20:47:48.223	Surface Ops Set Bellows	Optode Message																												Geographic Position,4330,1532,60.323605,5.37225  								

$	13-Dec-2018	20:47:48.253	Surface Ops Set Bellows	Optode Message																												Vertical Position,4330,1532,  								

$	13-Dec-2018	20:47:48.277	Surface Ops Set Bellows	Optode Message																												Reference,4330,1532,  								

$	13-Dec-2018	20:47:48.280	Surface Ops Set Bellows	Optode Message																												#  								

$	13-Dec-2018	20:47:59.320	Surface Ops Set Bellows	Normal State Exit

$	13-Dec-2018	20:47:59.324	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.081575	31.800000	163.500000																																

$	13-Dec-2018	20:47:59.539	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7508274

$	13-Dec-2018	20:47:59.545	Pre-Mission Delay	State Entry

$	13-Dec-2018	20:47:48.364	Pre-Mission Delay	SBE41 Message						   -0.15  	-0.150000	-0.120000	-0.000000	0.010000	0.005000	-0.000000	3.000000																							

$	13-Dec-2018	20:48:00.077	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.150000	139.076956	31.800000	163.500000																																

$	13-Dec-2018	20:47:51.448	Pre-Mission Delay	SBE41 Message						    0.55  	0.550000	-0.120058	-0.000001	-0.233333	-0.111667	0.000000	3.000000																							

$	13-Dec-2018	20:47:54.461	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:47:55.008	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:48:01.107	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.550000	139.096111	31.800000	163.500000																																

$	13-Dec-2018	20:48:01.750	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.550000	139.107443	31.800000	163.500000																																

$	13-Dec-2018	20:47:57.523	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	-0.119302	0.000011	0.220000	-0.006667	-0.000001	3.000000																							

$	13-Dec-2018	20:48:02.878	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.088981	31.800000	163.500000																																

$	13-Dec-2018	20:48:00.365	Pre-Mission Delay	SBE41 Message						   -0.06  	-0.060000	-0.106952	0.000129	-0.016667	0.101667	-0.000017	3.000000																							

$	13-Dec-2018	20:48:03.461	Pre-Mission Delay	SBE41 Message						   -0.12  	-0.120000	-0.057992	0.000184	0.020000	0.001667	-0.000092	3.000000																							

$	13-Dec-2018	20:48:04.001	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.079235	31.800000	163.500000																																

$	13-Dec-2018	20:48:04.749	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.077999	31.800000	163.500000																																

$	13-Dec-2018	20:48:05.748	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.069170	31.800000	163.500000																																

$	13-Dec-2018	20:48:06.365	Pre-Mission Delay	SBE41 Message						   -0.12  	-0.120000	0.025119	-0.001279	0.000000	0.010000	-0.000267	3.000000																							

$	13-Dec-2018	20:48:06.872	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.097653	31.800000	163.500000																																

$	13-Dec-2018	20:48:07.748	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.072850	31.800000	163.500000																																

$	13-Dec-2018	20:48:08.748	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.087081	31.800000	163.500000																																

$	13-Dec-2018	20:48:09.365	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	0.076934	-0.006128	-0.003333	-0.001667	-0.000496	3.000000																							

$	13-Dec-2018	20:48:09.776	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.082730	31.800000	163.500000																																

$	13-Dec-2018	20:48:10.030	Pre-Mission Delay	State Timed Out

$	13-Dec-2018	20:48:10.136	Surface Ops	State Entry

$	13-Dec-2018	20:48:10.141	Surface Ops	Powering up Iridium Modem

$	13-Dec-2018	20:48:20.001	Surface Ops	Starting valve close

$	13-Dec-2018	20:48:20.102	Surface Ops	Sending SBDD2 cmd

$	13-Dec-2018	20:48:20.415	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.093705	31.800000	163.500000																																

$	13-Dec-2018	20:48:20.526	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.4061189

$	13-Dec-2018	20:48:12.364	Surface Ops	SBE41 Message						   -0.10  	-0.100000	0.044834	-0.012862	-0.003333	-0.003333	-0.000673	3.000000																							

$	13-Dec-2018	20:48:13.258	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:20.864	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:13.260	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:21.079	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:14.258	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:21.293	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:14.260	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:21.504	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:15.260	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:21.718	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:15.262	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	20:48:21.929	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	20:48:15.263	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:22.143	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:22.352	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	139.078669	31.800000	163.500000																																

$	13-Dec-2018	20:48:22.465	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9331309

$	13-Dec-2018	20:48:15.265	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:22.676	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:15.364	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.032266	-0.016133	0.006667	0.001667	-0.000745	3.000000																							

$	13-Dec-2018	20:48:16.260	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:23.013	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:16.269	Surface Ops	A3LA Message																																			300125060561320  	

$	13-Dec-2018	20:48:23.227	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->300125060561320  <--  

$	13-Dec-2018	20:48:16.270	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:23.438	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:16.272	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:23.649	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:17.261	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:23.862	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:17.262	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	20:48:24.074	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	20:48:17.263	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:24.290	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:17.266	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:24.502	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:18.261	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:24.714	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:18.263	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:24.927	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:18.363	Surface Ops	SBE41 Message						   -0.11  	-0.110000	-0.087892	-0.012089	-0.003333	0.001667	-0.000742	3.000000																							

$	13-Dec-2018	20:48:25.358	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.093749	31.800000	163.500000																																

$	13-Dec-2018	20:48:25.472	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0020671

$	13-Dec-2018	20:48:19.263	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:25.684	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:19.274	Surface Ops	A3LA Message																																			8988169234000597401  	

$	13-Dec-2018	20:48:25.920	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->8988169234000597401  <--  

$	13-Dec-2018	20:48:19.275	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:26.132	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:19.278	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:26.343	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:20.210	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:26.556	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:20.210	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	20:48:26.767	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	20:48:20.210	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:48:26.984	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:48:20.210	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:48:27.196	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:48:21.608	Surface Ops	SBE41 Message						    0.04  	0.040000	-0.107890	-0.002073	-0.050000	-0.026667	-0.000712	3.000000																							

$	13-Dec-2018	20:48:24.605	Surface Ops	SBE41 Message						   -1.35  	-1.350000	-0.110529	0.008860	0.463333	0.206667	-0.000678	3.000000																							

$	13-Dec-2018	20:48:27.549	Surface Ops	SBE41 Message						    0.34  	0.340000	-0.109519	0.014979	-0.563333	-0.050000	-0.000645	3.000000																							

$	13-Dec-2018	20:48:27.779	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.340000	139.092408	31.800000	163.500000																																

$	13-Dec-2018	20:48:27.892	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4144915

$	13-Dec-2018	20:48:28.197	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.340000	139.091223	31.800000	163.500000																																

$	13-Dec-2018	20:48:29.101	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.340000	139.103413	31.800000	163.500000																																

$	13-Dec-2018	20:48:30.100	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.340000	139.102504	31.800000	163.500000																																

$	13-Dec-2018	20:48:30.450	Surface Ops	SBE41 Message						   -0.11  	-0.110000	-0.124424	0.013353	0.150000	-0.206667	-0.000593	3.000000																							

$	13-Dec-2018	20:48:31.128	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.081083	31.800000	163.500000																																

$	13-Dec-2018	20:48:32.102	Surface Ops	PTH Message														780.781738	23.558333	52.216095	24.386099																			

$	13-Dec-2018	20:48:32.304	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.117919	31.800000	157.000000																																

$	13-Dec-2018	20:48:33.102	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.092810	31.800000	157.000000																																

$	13-Dec-2018	20:48:33.449	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.193185	0.007033	0.003333	0.076667	-0.000456	3.000000																							

$	13-Dec-2018	20:48:34.129	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.117941	31.800000	157.000000																																

$	13-Dec-2018	20:48:35.101	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.116481	31.800000	157.000000																																

$	13-Dec-2018	20:48:36.102	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.097497	31.800000	157.000000																																

$	13-Dec-2018	20:48:36.450	Surface Ops	SBE41 Message						   -0.11  	-0.110000	-0.301326	0.003774	-0.003333	0.000000	-0.000190	3.000000																							

$	13-Dec-2018	20:48:37.131	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.113329	31.800000	157.000000																																

$	13-Dec-2018	20:48:38.103	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.110230	31.800000	157.000000																																

$	13-Dec-2018	20:48:39.103	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.098808	31.800000	157.000000																																

$	13-Dec-2018	20:48:39.449	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.336374	0.008489	-0.003333	-0.003333	0.000108	3.000000																							

$	13-Dec-2018	20:48:40.130	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	139.104582	31.800000	157.000000																																

$	13-Dec-2018	20:48:41.104	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	139.111176	31.800000	157.000000																																

$	13-Dec-2018	20:48:42.105	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	139.094293	31.800000	157.000000																																

$	13-Dec-2018	20:48:42.449	Surface Ops	SBE41 Message						   -0.11  	-0.110000	-0.244721	0.016466	0.003333	0.000000	0.000279	3.000000																							

$	13-Dec-2018	20:48:43.231	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.122747	31.800000	157.000000																																

$	13-Dec-2018	20:48:44.105	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.087781	31.800000	157.000000																																

$	13-Dec-2018	20:48:45.105	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	139.111057	31.800000	157.000000																																

$	13-Dec-2018	20:48:45.450	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.133358	0.017881	0.003333	0.003333	0.000304	3.000000																							

$	13-Dec-2018	20:48:46.132	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.106274	31.800000	157.000000																																

$	13-Dec-2018	20:48:46.904	Surface Ops	Processing Console Command: $exit

$	13-Dec-2018	20:48:47.209	Surface Ops	Normal State Exit

$	13-Dec-2018	20:48:47.213	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	139.105700	31.800000	157.000000																																

$	13-Dec-2018	20:48:47.904	Surface Ops	Closing .msg File

$	13-Dec-2018	20:48:47.908	Surface Ops	Closing .log File
