$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	13-Dec-2018	20:50:48.749	SM Not Running	Reset Controller Status Register Value = 65792

$	13-Dec-2018	20:50:48.754	SM Not Running	File Name = \SD\data\2018-12-13T20-50-47.eng

$	13-Dec-2018	20:50:48.759	SM Not Running	Volume Total Size:     7939817472

$	13-Dec-2018	20:50:48.763	SM Not Running	Volume Free Space:     7874445312

$	13-Dec-2018	20:50:48.767	SM Not Running	PlatVel PID K = 80

$	13-Dec-2018	20:50:48.771	SM Not Running	PlatVel PID Ti = 50000

$	13-Dec-2018	20:50:48.775	SM Not Running	PlatVel PID Td = 10

$	13-Dec-2018	20:50:48.779	SM Not Running	PlatVel PID Tf = 10

$	13-Dec-2018	20:50:48.783	SM Not Running	PlatVel PID Tt = 100

$	13-Dec-2018	20:50:48.787	SM Not Running	PlatVel PID B = 1

$	13-Dec-2018	20:50:48.792	SM Not Running	PlatVel PID uLow = -50

$	13-Dec-2018	20:50:48.796	SM Not Running	PlatVel PID uHigh = 50

$	13-Dec-2018	20:50:48.800	SM Not Running	PlatVel PID h = 3

$	13-Dec-2018	20:50:48.804	SM Not Running	Engr Logger Initialized

$	13-Dec-2018	20:50:49.724	SM Not Running	Initializing Bluetooth Console

$	13-Dec-2018	20:50:50.729	SM Not Running	Initializing GPS and synching time

$	13-Dec-2018	20:50:53.001	SM Not Running	Creating Mission

$	13-Dec-2018	20:50:53.104	SM Not Running	Maximum number of profiles = 10

$	13-Dec-2018	20:50:53.208	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 12/13/2018 20:50:53

$	13-Dec-2018	20:50:53.314	SM Not Running	Recovery mode = True

$	13-Dec-2018	20:50:53.419	SM Not Running	Park Sample Period = 00:01:00

$	13-Dec-2018	20:50:53.525	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	13-Dec-2018	20:50:53.632	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:53.739	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:53.846	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:53.953	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.061	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.168	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.275	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.381	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.489	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.596	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.703	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.811	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:54.918	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.025	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.132	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.239	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.346	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.453	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.562	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.669	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.776	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.883	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:55.991	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:56.098	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:56.208	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:56.314	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:56.423	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.050, 00:00:00, 7

$	13-Dec-2018	20:50:56.429	SM Not Running	Initializing Buoyancy Engine

$	13-Dec-2018	20:50:56.630	SM Not Running	Starting valve close

$	13-Dec-2018	20:50:56.635	Init Mission	State Entry

$	13-Dec-2018	20:50:56.736	Init Mission	Initializing FLBB

$	13-Dec-2018	20:51:01.341	Init Mission	Sending FLBB stop command

$	13-Dec-2018	20:51:02.847	Init Mission	Sending FLBB pkt command: $pkt 1  

$	13-Dec-2018	20:51:03.952	Init Mission	Sending FLBB ave command: $ave 10  

$	13-Dec-2018	20:51:05.959	Init Mission	Initializing Iridium Modem

$	13-Dec-2018	20:51:15.560	Init Mission	Initializing SBE41

$	13-Dec-2018	20:51:21.073	Init Mission	Sending SBE41 stopProfile

$	13-Dec-2018	20:51:22.176	Init Mission	pcutoff=1 

$	13-Dec-2018	20:51:23.180	Init Mission	Sending outputPTSyes

$	13-Dec-2018	20:51:24.282	Init Mission	Sending tsWait

$	13-Dec-2018	20:51:25.287	Init Mission	Sending 11 bin setup commands

$	13-Dec-2018	20:51:31.800	Init Mission	Initializing Optode

$	13-Dec-2018	20:51:32.305	Init Mission	Sending Optode Wakeup

$	13-Dec-2018	20:51:37.313	Init Mission	Initializing Pressure, Temperature, Humidity sensor

$	13-Dec-2018	20:51:37.820	Init Mission	Set can pressure resolution to low

$	13-Dec-2018	20:51:37.922	Init Mission	Set can pressure active

$	13-Dec-2018	20:51:37.927	Init Mission	PTH Message														781.590332	23.541667	52.078766	24.471899																			

$	13-Dec-2018	20:51:38.137	Init Mission	Initializing MSC

$	13-Dec-2018	20:51:38.739	Init Mission	MSC: OUT: INIT

$	13-Dec-2018	20:51:38.842	Init Mission	Initializing Radiometer 1

$	13-Dec-2018	20:51:39.414	Init Mission	Powering down OCR504

$	13-Dec-2018	20:51:44.419	Init Mission	Powering up OCR504

$	13-Dec-2018	20:51:09.567	Init Mission	A3LA Message																																			AT&D0   	

$	13-Dec-2018	20:51:09.569	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:10.568	Init Mission	A3LA Message																																			AT&K0   	

$	13-Dec-2018	20:51:10.570	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:11.571	Init Mission	A3LA Message																																			AT+SBDD2   	

$	13-Dec-2018	20:51:11.573	Init Mission	A3LA Message																																			0  	

$	13-Dec-2018	20:51:11.574	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:51:11.576	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:12.571	Init Mission	A3LA Message																																			AT+GSN    	

$	13-Dec-2018	20:51:12.579	Init Mission	A3LA Message																																			300125060561320  	

$	13-Dec-2018	20:51:12.580	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:51:12.582	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:13.803	Init Mission	A3LA Message																																			AT+SBDC   	

$	13-Dec-2018	20:51:13.804	Init Mission	A3LA Message																																			0  	

$	13-Dec-2018	20:51:13.805	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:51:13.807	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:51.361	Init Mission	PTH Message														781.590332	23.450000	52.132172	24.428999																			

$	13-Dec-2018	20:51:51.563	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	139.113717	31.825000	95.000000																																

$	13-Dec-2018	20:51:51.674	Init Mission	Starting valve close

$	13-Dec-2018	20:51:53.679	Init Mission	Closed valve isValveOpen = false

$	13-Dec-2018	20:51:53.776	Init Mission	Starting valve open

$	13-Dec-2018	20:51:55.976	Init Mission	Opened valve isValveOpen = true

$	13-Dec-2018	20:51:55.980	Init Mission	Starting valve close

$	13-Dec-2018	20:51:58.083	Init Mission	Closed valve isValveOpen = false

$	13-Dec-2018	20:51:14.572	Init Mission	A3LA Message																																			ATEn=0   	

$	13-Dec-2018	20:51:14.574	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:15.890	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:51:15.901	Init Mission	A3LA Message																																			8988169234000597401  	

$	13-Dec-2018	20:51:15.902	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	20:51:15.905	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	20:51:21.205	Init Mission	Unparsed SBE41 Message						S>stopprofile  																														

$	13-Dec-2018	20:51:22.289	Init Mission	Unparsed SBE41 Message						?cmd S>pcutoff=1  																														

$	13-Dec-2018	20:51:23.313	Init Mission	Unparsed SBE41 Message						S>outputpts=y  																														

$	13-Dec-2018	20:51:24.394	Init Mission	Unparsed SBE41 Message						S>tswait=2  																														

$	13-Dec-2018	20:51:25.405	Init Mission	Unparsed SBE41 Message						S>autobinavg=n  																														

$	13-Dec-2018	20:51:25.841	Init Mission	Unparsed SBE41 Message						S>top_bin_interval=2  																														

$	13-Dec-2018	20:51:26.332	Init Mission	Unparsed SBE41 Message						S>top_bin_size=2  																														

$	13-Dec-2018	20:51:26.832	Init Mission	Unparsed SBE41 Message						S>top_bin_max=10  																														

$	13-Dec-2018	20:51:27.349	Init Mission	Unparsed SBE41 Message						S>middle_bin_interval=2  																														

$	13-Dec-2018	20:52:00.085	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	31.825000	95.000000																																

$	13-Dec-2018	20:52:00.197	Init Mission	Starting valve open

$	13-Dec-2018	20:52:00.404	Init Mission	Bellows inside limits

$	13-Dec-2018	20:51:27.840	Init Mission	Unparsed SBE41 Message						S>middle_bin_size=2  																														

$	13-Dec-2018	20:51:28.341	Init Mission	Unparsed SBE41 Message						S>middle_bin_max=20  																														

$	13-Dec-2018	20:51:28.851	Init Mission	Unparsed SBE41 Message						S>bottom_bin_interval=2  																														

$	13-Dec-2018	20:51:29.342	Init Mission	Unparsed SBE41 Message						S>bottom_bin_size=2  																														

$	13-Dec-2018	20:51:29.856	Init Mission	Unparsed SBE41 Message						S>includetransitionbin=n  																														

$	13-Dec-2018	20:51:30.334	Init Mission	Unparsed SBE41 Message						S>includenbin=y  																														

$	13-Dec-2018	20:51:33.358	Init Mission	Optode Message																												*,ERROR,SYNTAX ERROR  								

$	13-Dec-2018	20:51:34.372	Init Mission	Optode Message																												*,ERROR,PROTECTED PROPERTY  								

$	13-Dec-2018	20:51:35.380	Init Mission	Optode Message																												*,ERROR,PROTECTED PROPERTY  								

$	13-Dec-2018	20:52:01.571	Init Mission	MSC: RX: 

$	13-Dec-2018	20:52:01.576	Init Mission	MSC: RX: 

$	13-Dec-2018	20:52:01.775	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	13-Dec-2018	20:52:01.878	Init Mission	MSC: RX:   MBARI Serial Number : 0777 

$	13-Dec-2018	20:52:01.980	Init Mission	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	13-Dec-2018	20:52:02.084	Init Mission	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	13-Dec-2018	20:52:02.089	Init Mission	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	13-Dec-2018	20:52:02.400	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	137.072004	31.825000	95.000000																																

$	13-Dec-2018	20:52:03.815	Init Mission	Increasing bellows position		137.871332																																		

$	13-Dec-2018	20:52:06.027	Init Mission	Increasing bellows position		138.210125																																		

$	13-Dec-2018	20:52:08.237	Init Mission	Increasing bellows position		138.579473																																		

$	13-Dec-2018	20:52:10.448	Init Mission	Increasing bellows position		138.868324																																		

$	13-Dec-2018	20:52:12.658	Init Mission	Increasing bellows position		138.923571																																		

$	13-Dec-2018	20:52:14.870	Init Mission	Increasing bellows position		138.966098																																		

$	13-Dec-2018	20:52:17.080	Init Mission	Increasing bellows position		138.990693																																		

$	13-Dec-2018	20:52:19.291	Init Mission	Increasing bellows position		139.013007																																		

$	13-Dec-2018	20:52:21.501	Init Mission	Increasing bellows position		139.024623																																		

$	13-Dec-2018	20:52:23.712	Init Mission	Increasing bellows position		139.028311																																		

$	13-Dec-2018	20:52:26.225	Init Mission	Decreasing bellows position		139.032789																																		

$	13-Dec-2018	20:52:28.435	Init Mission	Decreasing bellows position		139.048092																																		

$	13-Dec-2018	20:52:30.646	Init Mission	Decreasing bellows position		138.995014																																		

$	13-Dec-2018	20:52:32.856	Init Mission	Decreasing bellows position		138.984822																																		

$	13-Dec-2018	20:52:35.068	Init Mission	Decreasing bellows position		138.994083																																		

$	13-Dec-2018	20:52:37.278	Init Mission	Decreasing bellows position		138.892591																																		

$	13-Dec-2018	20:52:39.488	Init Mission	Decreasing bellows position		138.859332																																		

$	13-Dec-2018	20:52:41.698	Init Mission	Decreasing bellows position		138.807595																																		

$	13-Dec-2018	20:52:43.915	Init Mission	Decreasing bellows position		138.758749																																		

$	13-Dec-2018	20:52:46.125	Init Mission	Decreasing bellows position		138.688214																																		

$	13-Dec-2018	20:52:48.134	Init Mission	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	13-Dec-2018	20:52:48.332	Init Mission	Radiometer Message																																	Firmware version: 5.1.0 - SatNet Type B 			

$	13-Dec-2018	20:52:48.442	Init Mission	Radiometer Message																																	Instrument: SATFI4 			

$	13-Dec-2018	20:52:48.550	Init Mission	Radiometer Message																																	S/N: 0287 			

$	13-Dec-2018	20:52:48.658	Init Mission	Radiometer Message																																	Reset Source: Power 			

$	13-Dec-2018	20:52:48.669	Init Mission	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	13-Dec-2018	20:52:48.779	Init Mission	Radiometer Message																																	Initializing system. Please wait... 			

$	13-Dec-2018	20:52:48.888	Init Mission	MSC: RX:   CF Card: Size=256614400 Avail=99.09% 

$	13-Dec-2018	20:52:49.088	Init Mission	MSC: RX:   CF2 Power Up  (GMT): Wed Feb  1 03:16:51 2012 

$	13-Dec-2018	20:52:49.190	Init Mission	MSC: RX:   CF2 RTC Time  (GMT): Wed Feb  1 03:16:55 2012 

$	13-Dec-2018	20:52:49.293	Init Mission	MSC: RX:   Adjusted Local Time: Tue Jan 31 19:16:55 2012 

$	13-Dec-2018	20:52:49.300	Init Mission	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	13-Dec-2018	20:52:49.500	Init Mission	MSC: RX:   RTC delta (CF2 - DS3234) : -1.00 secs. 

$	13-Dec-2018	20:52:49.505	Init Mission	MSC: RX:   System Batt Voltage = 11.764 

$	13-Dec-2018	20:52:49.608	Init Mission	MSC: RX:   System Load Current = 2.62e-02 

$	13-Dec-2018	20:52:49.807	Init Mission	MSC: RX:   Housing Temperature = +22.24C = +72.02F 

$	13-Dec-2018	20:52:50.014	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	138.659485	31.825000	95.000000																																

$	13-Dec-2018	20:52:50.130	Init Mission	MSC: RX:   Housing    Humidity =  55.0%  =  12.8C (DP) 

$	13-Dec-2018	20:52:50.233	Init Mission	MSC: RX:   Power Cycle   Count = 162 

$	13-Dec-2018	20:52:50.335	Init Mission	MSC: RX:   System Reset  Count = 166 

$	13-Dec-2018	20:52:50.437	Init Mission	MSC: RX:   System Error  Count = 66 

$	13-Dec-2018	20:52:50.540	Init Mission	MSC: RX:   Last System   Error = -110 

$	13-Dec-2018	20:52:50.547	Init Mission	MSC: RX:   Last Error     Time = Tue Jan 31 02:58:15 2012 

$	13-Dec-2018	20:52:50.747	Init Mission	MSC: RX:   ISUS Error    Count = 1 

$	13-Dec-2018	20:52:50.849	Init Mission	MSC: RX:   Last ISUS     Error = -202 

$	13-Dec-2018	20:52:50.951	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	13-Dec-2018	20:52:51.054	Init Mission	MSC: RX:   DURA Error    Count = 0 

$	13-Dec-2018	20:52:51.060	Init Mission	MSC: RX:   Last DURA     Error = 0 

$	13-Dec-2018	20:52:51.162	Init Mission	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	13-Dec-2018	20:52:51.363	Init Mission	MSC: RX:   Fiberlite  Odometer = 100:12:10 = 360730 secs 

$	13-Dec-2018	20:52:51.465	Init Mission	MSC: RX:   Fiberlite    Cycles = 254 

$	13-Dec-2018	20:52:51.568	Init Mission	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	13-Dec-2018	20:52:51.671	Init Mission	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	13-Dec-2018	20:52:51.976	Init Mission	PTH Message														781.645264	23.433333	52.185577	24.418274																			

$	13-Dec-2018	20:52:52.178	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	138.548881	31.775000	153.000000																																

$	13-Dec-2018	20:52:52.289	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:52:52.294	Init Mission	Sending ds command

$	13-Dec-2018	20:52:52.500	Init Mission	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	13-Dec-2018	20:52:52.606	Init Mission	MSC: RX:   There are 72 records in the error file! 

$	13-Dec-2018	20:52:52.611	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	13-Dec-2018	20:52:52.817	Init Mission	MSC: RX:   Auto Shutdown in 10 hours at: Wed Feb  1 13:16:56 2012 

$	13-Dec-2018	20:52:52.922	Init Mission	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	13-Dec-2018	20:52:53.027	Init Mission	Radiometer Message																																	Autonomous operation enabled. 			

$	13-Dec-2018	20:51:50.066	Init Mission	SBE41 Message						    0.11  	0.110000	0.000001	0.000000	-0.036667	-0.018333	-0.000000	3.000000																							

$	13-Dec-2018	20:52:53.467	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.557553	31.775000	153.000000																																

$	13-Dec-2018	20:52:53.580	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:52:53.885	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.560139	31.775000	153.000000																																

$	13-Dec-2018	20:52:54.580	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:52:52.498	Init Mission	Unparsed SBE41 Message						S>ds  																														

$	13-Dec-2018	20:52:52.603	Init Mission	Unparsed SBE41 Message						firmware compilation date: 18 December 2007 09:20  																														

$	13-Dec-2018	20:52:52.605	Init Mission	Unparsed SBE41 Message						stop profile when pressure is less than = 1.0 decibars  																														

$	13-Dec-2018	20:52:52.710	Init Mission	Unparsed SBE41 Message						automatic bin averaging at end of profile disabled  																														

$	13-Dec-2018	20:52:52.711	Init Mission	Unparsed SBE41 Message						number of samples = 264  																														

$	13-Dec-2018	20:52:52.711	Init Mission	Unparsed SBE41 Message						number of bins = 0  																														

$	13-Dec-2018	20:52:55.493	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.535082	31.775000	153.000000																																

$	13-Dec-2018	20:52:55.605	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:52:52.815	Init Mission	Unparsed SBE41 Message						top bin interval = 2  																														

$	13-Dec-2018	20:52:52.815	Init Mission	Unparsed SBE41 Message						top bin size = 2  																														

$	13-Dec-2018	20:52:52.816	Init Mission	Unparsed SBE41 Message						top bin max = 10  																														

$	13-Dec-2018	20:52:52.919	Init Mission	Unparsed SBE41 Message						middle bin interval = 2  																														

$	13-Dec-2018	20:52:52.920	Init Mission	Unparsed SBE41 Message						middle bin size = 2  																														

$	13-Dec-2018	20:52:52.921	Init Mission	Unparsed SBE41 Message						middle bin max = 20  																														

$	13-Dec-2018	20:52:53.026	Init Mission	Unparsed SBE41 Message						bottom bin interval = 2  																														

$	13-Dec-2018	20:52:53.136	Init Mission	Unparsed SBE41 Message						bottom bin size = 2  																														

$	13-Dec-2018	20:52:53.137	Init Mission	Unparsed SBE41 Message						do not include two transition bins  																														

$	13-Dec-2018	20:52:53.157	Init Mission	Unparsed SBE41 Message						include samples per bin  																														

$	13-Dec-2018	20:52:53.158	Init Mission	Unparsed SBE41 Message						pumped take sample wait time = 2 sec  																														

$	13-Dec-2018	20:52:53.159	Init Mission	Unparsed SBE41 Message						real-time output is PTS  																														

$	13-Dec-2018	20:52:57.318	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.544396	31.775000	153.000000																																

$	13-Dec-2018	20:52:57.434	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	20:52:57.640	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.540819	31.775000	153.000000																																

$	13-Dec-2018	20:52:58.434	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:52:58.439	Init Mission	Sending dc command

$	13-Dec-2018	20:52:58.742	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.537832	31.775000	153.000000																																

$	13-Dec-2018	20:52:59.435	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:52:58.642	Init Mission	Unparsed SBE41 Message						S>dc  																														

$	13-Dec-2018	20:52:58.643	Init Mission	Unparsed SBE41 Message						temperature:  15-mar-14  																														

$	13-Dec-2018	20:52:58.671	Init Mission	Unparsed SBE41 Message						    TA0 =  3.536242e-05  																														

$	13-Dec-2018	20:52:58.707	Init Mission	Unparsed SBE41 Message						    TA1 =  2.674251e-04  																														

$	13-Dec-2018	20:52:58.855	Init Mission	Unparsed SBE41 Message						    TA2 = -1.901062e-06  																														

$	13-Dec-2018	20:52:58.855	Init Mission	Unparsed SBE41 Message						    TA3 =  1.365250e-07  																														

$	13-Dec-2018	20:52:58.856	Init Mission	Unparsed SBE41 Message						conductivity:  15-mar-14  																														

$	13-Dec-2018	20:52:58.857	Init Mission	Unparsed SBE41 Message						    G = -9.858232e-01  																														

$	13-Dec-2018	20:52:58.882	Init Mission	Unparsed SBE41 Message						    H =  1.476071e-01  																														

$	13-Dec-2018	20:52:58.915	Init Mission	Unparsed SBE41 Message						    I = -3.292498e-04  																														

$	13-Dec-2018	20:52:58.949	Init Mission	Unparsed SBE41 Message						    J =  4.505543e-05  																														

$	13-Dec-2018	20:52:58.987	Init Mission	Unparsed SBE41 Message						    CPCOR = -9.570001e-08  																														

$	13-Dec-2018	20:52:59.025	Init Mission	Unparsed SBE41 Message						    CTCOR =  3.250000e-06  																														

$	13-Dec-2018	20:52:59.064	Init Mission	Unparsed SBE41 Message						    WBOTC = -3.218098e-07  																														

$	13-Dec-2018	20:52:59.147	Init Mission	Unparsed SBE41 Message						pressure S/N = 4004719, range = 2900 psia:  10-mar-14  																														

$	13-Dec-2018	20:53:01.507	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.536856	31.775000	153.000000																																

$	13-Dec-2018	20:53:01.618	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:52:59.183	Init Mission	Unparsed SBE41 Message						    PA0 =  1.629284e-01  																														

$	13-Dec-2018	20:52:59.219	Init Mission	Unparsed SBE41 Message						    PA1 =  1.404717e-01  																														

$	13-Dec-2018	20:52:59.254	Init Mission	Unparsed SBE41 Message						    PA2 = -3.503310e-08  																														

$	13-Dec-2018	20:52:59.294	Init Mission	Unparsed SBE41 Message						    PTCA0 =  2.758681e+01  																														

$	13-Dec-2018	20:52:59.332	Init Mission	Unparsed SBE41 Message						    PTCA1 =  2.201518e-02  																														

$	13-Dec-2018	20:52:59.370	Init Mission	Unparsed SBE41 Message						    PTCA2 =  1.374282e-03  																														

$	13-Dec-2018	20:52:59.409	Init Mission	Unparsed SBE41 Message						    PTCB0 =  2.510888e+01  																														

$	13-Dec-2018	20:52:59.537	Init Mission	Unparsed SBE41 Message						    PTCB1 =  1.175000e-03  																														

$	13-Dec-2018	20:52:59.538	Init Mission	Unparsed SBE41 Message						    PTCB2 =  0.000000e+00  																														

$	13-Dec-2018	20:52:59.539	Init Mission	Unparsed SBE41 Message						    PTHA0 = -7.442904e+01  																														

$	13-Dec-2018	20:52:59.658	Init Mission	Unparsed SBE41 Message						    PTHA1 =  4.994783e-02  																														

$	13-Dec-2018	20:52:59.659	Init Mission	Unparsed SBE41 Message						    PTHA2 = -3.966033e-07  																														

$	13-Dec-2018	20:52:59.660	Init Mission	Unparsed SBE41 Message						    POFFSET =  0.000000e+00  																														

$	13-Dec-2018	20:53:03.353	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.537921	31.775000	153.000000																																

$	13-Dec-2018	20:53:03.465	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	20:53:03.768	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.563208	31.775000	153.000000																																

$	13-Dec-2018	20:53:04.667	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.110000	138.554841	31.775000	153.000000																																

$	13-Dec-2018	20:53:05.466	Init Mission	Sending Optode GetAll

$	13-Dec-2018	20:53:05.470	Init Mission	Sending Optode Wakeup

$	13-Dec-2018	20:53:05.438	Init Mission	SBE41 Message						   -0.11  	-0.110000	0.000232	0.000003	0.073333	0.018333	-0.000000	3.000000																							

$	13-Dec-2018	20:53:06.142	Init Mission	Optode Message																												%!Product Name,4330,1532,Optode Sensor  								

$	13-Dec-2018	20:53:06.174	Init Mission	Optode Message																												Product Number,4330,1532,4330  								

$	13-Dec-2018	20:53:06.206	Init Mission	Optode Message																												Serial Number,4330,1532,1532  								

$	13-Dec-2018	20:53:06.231	Init Mission	Optode Message																												SW ID,4330,1532,1940006  								

$	13-Dec-2018	20:53:06.261	Init Mission	Optode Message																												SW Version,4330,1532,4,8,1  								

$	13-Dec-2018	20:53:06.302	Init Mission	Optode Message																												Node Description,4330,1532,optode 1532  								

$	13-Dec-2018	20:53:06.321	Init Mission	Optode Message																												Owner,4330,1532,  								

$	13-Dec-2018	20:53:06.352	Init Mission	Optode Message																												Salinity[PSU],4330,1532,0.00  								

$	13-Dec-2018	20:53:06.428	Init Mission	Optode Message																												PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	20:53:06.453	Init Mission	Optode Message																												FoilID,4330,1532,1206E  								

$	13-Dec-2018	20:53:06.672	Init Mission	Optode Message																												FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04  								

$	13-Dec-2018	20:53:06.887	Init Mission	Optode Message																												FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	20:53:06.971	Init Mission	Optode Message																												FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0  								

$	13-Dec-2018	20:53:10.971	Init Mission	Normal State Exit

$	13-Dec-2018	20:53:10.977	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.546027	31.775000	153.000000																																

$	13-Dec-2018	20:53:11.191	Init Profile	State Entry

$	13-Dec-2018	20:53:11.195	Init Profile	Initializing SBE 41 LPF

$	13-Dec-2018	20:53:11.404	Init Profile	Sending SBE41 stopProfile

$	13-Dec-2018	20:53:12.409	Init Profile	Resetting SBE41 with qsr

$	13-Dec-2018	20:53:12.511	Init Profile	Sending qsr command

$	13-Dec-2018	20:53:07.053	Init Profile	Optode Message																												FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0  								

$	13-Dec-2018	20:53:07.172	Init Profile	Optode Message																												SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	20:53:07.221	Init Profile	Optode Message																												ConcCoef,4330,1532,-1.549127E+00,1.068129E+00  								

$	13-Dec-2018	20:53:07.258	Init Profile	Optode Message																												NomAirPress[hPa],4330,1532,1013.25  								

$	13-Dec-2018	20:53:07.288	Init Profile	Optode Message																												NomAirMix,4330,1532,0.20946  								

$	13-Dec-2018	20:53:07.329	Init Profile	Optode Message																												CalDataSat[Deg],4330,1532,31.61,10.06  								

$	13-Dec-2018	20:53:07.369	Init Profile	Optode Message																												CalDataAPress[hPa],4330,1532,1002.000  								

$	13-Dec-2018	20:53:07.413	Init Profile	Optode Message																												CalDataZero[Deg],4330,1532,61.907,21.413  								

$	13-Dec-2018	20:53:07.452	Init Profile	Optode Message																												Mode,4330,1532,Smart Sensor Terminal  								

$	13-Dec-2018	20:53:07.481	Init Profile	Optode Message																												Enable Sleep,4330,1532,Yes  								

$	13-Dec-2018	20:53:07.517	Init Profile	Optode Message																												Enable Polled Mode,4330,1532,Yes  								

$	13-Dec-2018	20:53:07.545	Init Profile	Optode Message																												Enable Text,4330,1532,Yes  								

$	13-Dec-2018	20:53:07.583	Init Profile	Optode Message																												Enable Decimalformat,4330,1532,Yes  								

$	13-Dec-2018	20:53:07.631	Init Profile	Optode Message																												Analog TempLimit[Deg.C],4330,1532,-5.00,35.00  								

$	13-Dec-2018	20:53:07.680	Init Profile	Optode Message																												Analog ConcLimit[Deg.C],4330,1532,0.00,800.00  								

$	13-Dec-2018	20:53:07.728	Init Profile	Optode Message																												Analog SatLimit[Deg.C],4330,1532,0.00,200.00  								

$	13-Dec-2018	20:53:16.631	Init Profile	Normal State Exit

$	13-Dec-2018	20:53:16.635	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.577171	31.775000	153.000000																																

$	13-Dec-2018	20:53:16.848	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.6572610

$	13-Dec-2018	20:53:16.952	Surface Ops Set Bellows	State Entry

$	13-Dec-2018	20:53:17.063	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	13-Dec-2018	20:53:07.778	Surface Ops Set Bellows	Optode Message																												Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00  								

$	13-Dec-2018	20:53:07.820	Surface Ops Set Bellows	Optode Message																												Analog Output,4330,1532,O2Concentration  								

$	13-Dec-2018	20:53:07.872	Surface Ops Set Bellows	Optode Message																												Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	13-Dec-2018	20:53:07.924	Surface Ops Set Bellows	Optode Message																												Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	13-Dec-2018	20:53:07.962	Surface Ops Set Bellows	Optode Message																												Enable AirSaturation,4330,1532,Yes  								

$	13-Dec-2018	20:53:07.993	Surface Ops Set Bellows	Optode Message																												Enable Rawdata,4330,1532,Yes  								

$	13-Dec-2018	20:53:08.028	Surface Ops Set Bellows	Optode Message																												Enable Temperature,4330,1532,Yes  								

$	13-Dec-2018	20:53:08.064	Surface Ops Set Bellows	Optode Message																												Enable HumidityComp,4330,1532,Yes  								

$	13-Dec-2018	20:53:08.098	Surface Ops Set Bellows	Optode Message																												Enable SVUformula,4330,1532,No  								

$	13-Dec-2018	20:53:08.129	Surface Ops Set Bellows	Optode Message																												Interval[s],4330,1532,30.000  								

$	13-Dec-2018	20:53:08.151	Surface Ops Set Bellows	Optode Message																												Location,4330,1532,  								

$	13-Dec-2018	20:53:08.202	Surface Ops Set Bellows	Optode Message																												Geographic Position,4330,1532,60.323605,5.37225  								

$	13-Dec-2018	20:53:08.232	Surface Ops Set Bellows	Optode Message																												Vertical Position,4330,1532,  								

$	13-Dec-2018	20:53:08.256	Surface Ops Set Bellows	Optode Message																												Reference,4330,1532,  								

$	13-Dec-2018	20:53:08.259	Surface Ops Set Bellows	Optode Message																												#  								

$	13-Dec-2018	20:53:19.486	Surface Ops Set Bellows	Normal State Exit

$	13-Dec-2018	20:53:19.490	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.550207	31.775000	153.000000																																

$	13-Dec-2018	20:53:19.706	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7529988

$	13-Dec-2018	20:53:19.808	Pre-Mission Delay	State Entry

$	13-Dec-2018	20:53:08.438	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	-0.110000	-0.000000	0.000000	0.000000	-0.000000	3.000000																							

$	13-Dec-2018	20:53:20.247	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.541482	31.775000	153.000000																																

$	13-Dec-2018	20:53:11.520	Pre-Mission Delay	SBE41 Message						    0.39  	0.390000	-0.109996	0.000000	-0.166667	-0.083333	-0.000000	3.000000																							

$	13-Dec-2018	20:53:14.539	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:53:15.076	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:53:21.374	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.390000	138.547920	31.775000	153.000000																																

$	13-Dec-2018	20:53:22.013	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.390000	138.553530	31.775000	153.000000																																

$	13-Dec-2018	20:53:17.592	Pre-Mission Delay	SBE41 Message						   -0.12  	-0.120000	-0.108942	0.000012	0.170000	0.001667	-0.000001	3.000000																							

$	13-Dec-2018	20:53:23.142	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.552830	31.775000	153.000000																																

$	13-Dec-2018	20:53:20.512	Pre-Mission Delay	SBE41 Message						    0.13  	0.130000	-0.098012	0.000099	-0.083333	0.043333	-0.000016	3.000000																							

$	13-Dec-2018	20:53:23.437	Pre-Mission Delay	SBE41 Message						   -0.10  	-0.100000	-0.058672	0.000085	0.076667	-0.003333	-0.000078	3.000000																							

$	13-Dec-2018	20:53:24.167	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.566099	31.775000	153.000000																																

$	13-Dec-2018	20:53:25.012	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.560534	31.775000	153.000000																																

$	13-Dec-2018	20:53:26.013	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.584487	31.775000	153.000000																																

$	13-Dec-2018	20:53:26.437	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	0.007750	-0.001143	0.003333	0.040000	-0.000220	3.000000																							

$	13-Dec-2018	20:53:27.041	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.571687	31.775000	153.000000																																

$	13-Dec-2018	20:53:28.013	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.583124	31.775000	153.000000																																

$	13-Dec-2018	20:53:29.015	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.566658	31.775000	153.000000																																

$	13-Dec-2018	20:53:29.438	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	0.058255	-0.004943	0.000000	0.001667	-0.000416	3.000000																							

$	13-Dec-2018	20:53:30.139	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.569191	31.775000	153.000000																																

$	13-Dec-2018	20:53:30.505	Pre-Mission Delay	State Timed Out

$	13-Dec-2018	20:53:30.509	Surface Ops	State Entry

$	13-Dec-2018	20:53:30.719	Surface Ops	Powering up Iridium Modem

$	13-Dec-2018	20:53:40.001	Surface Ops	Starting valve close

$	13-Dec-2018	20:53:40.102	Surface Ops	Sending SBDD2 cmd

$	13-Dec-2018	20:53:40.415	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.559274	31.775000	153.000000																																

$	13-Dec-2018	20:53:40.526	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.0040107

$	13-Dec-2018	20:53:32.437	Surface Ops	SBE41 Message						   -0.10  	-0.100000	0.055327	-0.010415	-0.003333	-0.001667	-0.000598	3.000000																							

$	13-Dec-2018	20:53:33.732	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:40.864	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:33.734	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:41.075	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:34.732	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:41.292	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:34.734	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:41.504	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:35.437	Surface Ops	SBE41 Message						   -0.09  	-0.090000	0.011049	-0.014029	-0.003333	-0.003333	-0.000715	3.000000																							

$	13-Dec-2018	20:53:35.733	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:41.841	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:35.735	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	20:53:42.053	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	20:53:42.264	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	138.559870	31.775000	153.000000																																

$	13-Dec-2018	20:53:42.376	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8429729

$	13-Dec-2018	20:53:35.736	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:42.588	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:35.738	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:42.802	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:36.739	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:43.013	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:36.748	Surface Ops	A3LA Message																																			300125060561320  	

$	13-Dec-2018	20:53:43.226	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->300125060561320  <--  

$	13-Dec-2018	20:53:36.750	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:43.438	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:36.751	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:43.651	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:37.740	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:43.862	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:37.741	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	20:53:44.074	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	20:53:37.742	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:44.291	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:37.745	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:44.502	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:38.438	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.041582	-0.012595	0.003333	0.000000	-0.000759	3.000000																							

$	13-Dec-2018	20:53:38.739	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:44.839	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:38.741	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:45.053	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:45.360	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.550736	31.775000	153.000000																																

$	13-Dec-2018	20:53:45.472	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0906111

$	13-Dec-2018	20:53:39.741	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:45.684	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:39.752	Surface Ops	A3LA Message																																			8988169234000597401  	

$	13-Dec-2018	20:53:45.921	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->8988169234000597401  <--  

$	13-Dec-2018	20:53:39.753	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:46.132	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:39.755	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:46.345	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:40.210	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:46.556	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:40.210	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	20:53:46.768	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	20:53:40.211	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	20:53:46.981	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	20:53:40.211	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	20:53:47.196	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	20:53:41.607	Surface Ops	SBE41 Message						    0.33  	0.330000	-0.080887	-0.005698	-0.143333	-0.070000	-0.000750	3.000000																							

$	13-Dec-2018	20:53:44.605	Surface Ops	SBE41 Message						   -0.38  	-0.380000	-0.097761	0.003895	0.236667	0.046667	-0.000719	3.000000																							

$	13-Dec-2018	20:53:47.549	Surface Ops	SBE41 Message						    0.36  	0.360000	-0.090797	0.011417	-0.246667	-0.005000	-0.000695	3.000000																							

$	13-Dec-2018	20:53:47.876	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.360000	138.566740	31.775000	153.000000																																

$	13-Dec-2018	20:53:47.991	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4164043

$	13-Dec-2018	20:53:48.198	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.360000	138.581671	31.775000	153.000000																																

$	13-Dec-2018	20:53:49.199	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.360000	138.578482	31.775000	153.000000																																

$	13-Dec-2018	20:53:50.199	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.360000	138.580285	31.775000	153.000000																																

$	13-Dec-2018	20:53:50.451	Surface Ops	SBE41 Message						    0.71  	0.710000	-0.060176	0.013137	-0.116667	-0.181667	-0.000708	3.000000																							

$	13-Dec-2018	20:53:51.228	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.710000	138.585843	31.775000	153.000000																																

$	13-Dec-2018	20:53:52.200	Surface Ops	PTH Message														780.946289	23.533333	52.078766	24.493350																			

$	13-Dec-2018	20:53:52.402	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.710000	138.578676	31.775000	NaN																																

$	13-Dec-2018	20:53:53.200	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.710000	138.571873	31.775000	NaN																																

$	13-Dec-2018	20:53:53.451	Surface Ops	SBE41 Message						    0.91  	0.910000	-0.016656	0.008922	-0.066667	-0.091667	-0.000771	3.000000																							

$	13-Dec-2018	20:53:54.227	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.910000	138.586059	31.775000	NaN																																

$	13-Dec-2018	20:53:54.998	Surface Ops	Processing Console Command: $go

$	13-Dec-2018	20:53:55.302	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.910000	138.566971	31.775000	NaN																																

$	13-Dec-2018	20:53:56.201	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.910000	138.576016	31.775000	NaN																																

$	13-Dec-2018	20:53:56.451	Surface Ops	SBE41 Message						    0.75  	0.750000	0.031659	0.001769	0.053333	-0.006667	-0.000889	3.000000																							

$	13-Dec-2018	20:53:57.227	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.750000	138.580956	31.775000	NaN																																

$	13-Dec-2018	20:53:57.998	Surface Ops	Powering up 4330 Optode

$	13-Dec-2018	20:53:59.600	Surface Ops	Sending Optode Wakeup

$	13-Dec-2018	20:54:03.628	Surface Ops	Powering up OCR504

$	13-Dec-2018	20:54:03.730	Surface Ops	Closing old engr log file: \SD\data\2018-12-13T20-50-47.eng
