$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	13-Dec-2018	20:54:05.564	Surface Ops	Opened new engr log file: \SD\data\2018-12-13T20-54-3.eng

$	13-Dec-2018	20:54:05.570	Surface Ops	Profile Number = 0

$	13-Dec-2018	20:54:05.671	Surface Ops	Writing Header to msg File

$	13-Dec-2018	20:54:06.874	Surface Ops	Starting Surface Optode and OCR Samples

$	13-Dec-2018	20:54:07.985	Surface Ops	Sending Optode Do Sample

$	13-Dec-2018	20:54:07.989	Surface Ops	Sending Optode Wakeup

$	13-Dec-2018	20:54:08.593	Surface Ops	Sci Logger sample Optode

$	13-Dec-2018	20:54:08.610	Surface Ops	Sending radiometer pollSample

$	13-Dec-2018	20:54:08.809	Surface Ops	Sci Logger sample Radiometer

$	13-Dec-2018	20:53:59.451	Surface Ops	SBE41 Message						   -0.11  	-0.110000	0.128499	-0.004865	0.286667	0.170000	-0.001117	3.000000																							

$	13-Dec-2018	20:54:00.631	Surface Ops	Optode Message																												#  								

$	13-Dec-2018	20:54:01.657	Surface Ops	Optode Message																												#  								

$	13-Dec-2018	20:54:02.451	Surface Ops	SBE41 Message						   -0.11  	-0.110000	0.321335	-0.010761	0.000000	0.143333	-0.001567	3.000000																							

$	13-Dec-2018	20:54:02.669	Surface Ops	Optode Message																												#  								

$	13-Dec-2018	20:54:05.450	Surface Ops	SBE41 Message						   -0.08  	-0.080000	0.536596	-0.019950	-0.010000	-0.005000	-0.002256	3.000000																							

$	13-Dec-2018	20:54:08.450	Surface Ops	SBE41 Message						   -0.12  	-0.120000	0.609506	-0.034585	0.013333	0.001667	-0.002994	3.000000																							

$	13-Dec-2018	20:54:09.884	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.570033	31.775000	NaN																																

$	13-Dec-2018	20:54:09.997	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:11.9985712

$	13-Dec-2018	20:54:10.100	Surface Ops	Radiometer Message																																	SATFI40287,-0.0045,-0.0012,-0.0075,-0.2283 			

$	13-Dec-2018	20:54:10.214	Surface Ops	Radiometer post: SATFI40287,-0.0045,-0.0012,-0.0075,-0.2283 

$	13-Dec-2018	20:54:09.815	Surface Ops	Optode Message																												4330,1532,266.413,22.320,29.156,29.086,36.137,7.051,531.7,464.8,116.2  								

$	13-Dec-2018	20:54:16.930	Surface Ops	Optode post: 4330,1532,266.413,22.320,29.156,29.086,36.137,7.051,531.7,464.8,116.2  

$	13-Dec-2018	20:54:09.815	Surface Ops	Optode Message																												#  								

$	13-Dec-2018	20:54:17.255	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.576292	31.775000	NaN																																

$	13-Dec-2018	20:54:17.367	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:07.3642438

$	13-Dec-2018	20:54:17.575	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.573647	31.775000	NaN																																

$	13-Dec-2018	20:54:17.472	Surface Ops	SBE41 Message						   -0.49  	-0.490000	0.466364	-0.048002	0.123333	0.068333	-0.003515	3.000000																							

$	13-Dec-2018	20:54:18.603	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.490000	138.570018	31.775000	NaN																																

$	13-Dec-2018	20:54:19.578	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.490000	138.573028	31.775000	NaN																																

$	13-Dec-2018	20:54:19.983	Surface Ops	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:54:20.597	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.490000	138.580732	31.775000	NaN																																

$	13-Dec-2018	20:54:21.577	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.490000	138.576046	31.775000	NaN																																

$	13-Dec-2018	20:54:22.578	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.490000	138.590232	31.775000	NaN																																

$	13-Dec-2018	20:54:22.449	Surface Ops	SBE41 Message						   -0.10  	-0.100000	0.211203	-0.047731	-0.130000	-0.003333	-0.003638	3.000000																							

$	13-Dec-2018	20:54:23.605	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.568379	31.775000	NaN																																

$	13-Dec-2018	20:54:24.579	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.571858	31.775000	NaN																																

$	13-Dec-2018	20:54:25.578	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.564363	31.775000	NaN																																

$	13-Dec-2018	20:54:25.451	Surface Ops	SBE41 Message						   -0.10  	-0.100000	0.000712	-0.026675	0.000000	-0.065000	-0.003461	3.000000																							

$	13-Dec-2018	20:54:26.605	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.585597	31.775000	NaN																																

$	13-Dec-2018	20:54:27.579	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.566129	31.775000	NaN																																

$	13-Dec-2018	20:54:28.578	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.561398	31.775000	NaN																																

$	13-Dec-2018	20:54:29.381	Surface Ops	Done with finishSurfaceOps

$	13-Dec-2018	20:54:28.450	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.119238	0.009174	0.000000	0.000000	-0.003131	3.000000																							

$	13-Dec-2018	20:54:29.811	Surface Ops	Normal State Exit

$	13-Dec-2018	20:54:29.815	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.577722	31.775000	NaN																																

$	13-Dec-2018	20:54:30.377	AB Dec Buoycy Fast	State Entry

$	13-Dec-2018	20:54:30.484	AB Dec Buoycy Fast	Decreasing Buoyancy to pressure = 0.29999999999999999 at 200000 cps

$	13-Dec-2018	20:54:30.587	AB Dec Buoycy Fast	Initializing SBE 41 LPF

$	13-Dec-2018	20:54:30.695	AB Dec Buoycy Fast	Waiting 00:00:15 for sampling to finish before ABRetractFast

$	13-Dec-2018	20:54:31.002	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.577931	31.775000	NaN																																

$	13-Dec-2018	20:54:31.580	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.588049	31.775000	NaN																																

$	13-Dec-2018	20:54:31.450	AB Dec Buoycy Fast	SBE41 Message						   -0.11  	-0.110000	-0.100000	-0.000000	0.003333	0.001667	0.000000	3.000000																							

$	13-Dec-2018	20:54:32.606	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.569348	31.775000	NaN																																

$	13-Dec-2018	20:54:33.579	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.580672	31.775000	NaN																																

$	13-Dec-2018	20:54:34.580	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.592944	31.775000	NaN																																

$	13-Dec-2018	20:54:34.450	AB Dec Buoycy Fast	SBE41 Message						   -0.12  	-0.120000	-0.100021	-0.000000	0.003333	0.003333	0.000000	3.000000																							

$	13-Dec-2018	20:54:35.608	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.585195	31.775000	NaN																																

$	13-Dec-2018	20:54:36.579	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.597064	31.775000	NaN																																

$	13-Dec-2018	20:54:37.580	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.568401	31.775000	NaN																																

$	13-Dec-2018	20:54:37.450	AB Dec Buoycy Fast	SBE41 Message						   -0.12  	-0.120000	-0.100283	-0.000002	0.000000	0.001667	0.000000	3.000000																							

$	13-Dec-2018	20:54:38.606	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.565823	31.775000	NaN																																

$	13-Dec-2018	20:54:39.579	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.591565	31.775000	NaN																																

$	13-Dec-2018	20:54:40.580	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.583638	31.775000	NaN																																

$	13-Dec-2018	20:54:40.451	AB Dec Buoycy Fast	SBE41 Message						   -0.12  	-0.120000	-0.101544	-0.000006	0.000000	0.000000	0.000002	3.000000																							

$	13-Dec-2018	20:54:41.607	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.574697	31.775000	NaN																																

$	13-Dec-2018	20:54:42.580	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.568126	31.775000	NaN																																

$	13-Dec-2018	20:54:43.598	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	138.582833	31.775000	NaN																																

$	13-Dec-2018	20:54:43.451	AB Dec Buoycy Fast	SBE41 Message						   -0.10  	-0.100000	-0.104825	0.000016	-0.006667	-0.003333	0.000008	3.000000																							

$	13-Dec-2018	20:54:44.624	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.592295	31.775000	NaN																																

$	13-Dec-2018	20:54:45.598	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.580613	31.775000	NaN																																

$	13-Dec-2018	20:54:46.598	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.563097	31.775000	NaN																																

$	13-Dec-2018	20:54:47.396	AB Dec Buoycy Fast	Disabling unneeded power

$	13-Dec-2018	20:54:47.400	AB Dec Buoycy Fast	Powering down MSC

$	13-Dec-2018	20:54:47.502	AB Dec Buoycy Fast	Powering down GPS

$	13-Dec-2018	20:54:47.603	AB Dec Buoycy Fast	Powering down MSC

$	13-Dec-2018	20:54:47.705	AB Dec Buoycy Fast	Powering down FLBB

$	13-Dec-2018	20:54:47.904	AB Dec Buoycy Fast	Powering down 4330 Optode

$	13-Dec-2018	20:54:47.908	AB Dec Buoycy Fast	Powering down OCR504

$	13-Dec-2018	20:54:48.011	AB Dec Buoycy Fast	Powering down Bluetooth

$	13-Dec-2018	20:54:51.114	AB Dec Buoycy Fast	Powering down BT Module

$	13-Dec-2018	20:54:46.450	AB Dec Buoycy Fast	SBE41 Message						   -0.11  	-0.110000	-0.109958	0.000140	0.003333	-0.001667	0.000020	3.000000																							

$	13-Dec-2018	20:54:49.450	AB Dec Buoycy Fast	SBE41 Message						   -0.10  	-0.100000	-0.114673	0.000443	-0.003333	0.000000	0.000037	3.000000																							

$	13-Dec-2018	20:54:51.568	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	138.572201	31.775000	NaN																																

$	13-Dec-2018	20:54:51.680	AB Dec Buoycy Fast	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.2841784

$	13-Dec-2018	20:54:51.686	AB Dec Buoycy Fast	Starting valve open

$	13-Dec-2018	20:54:52.451	AB Dec Buoycy Fast	SBE41 Message						   -0.11  	-0.110000	-0.116131	0.000880	0.003333	0.000000	0.000054	3.000000																							

$	13-Dec-2018	20:54:53.718	AB Dec Buoycy Fast	PTH Message														781.575195	23.716667	51.971954	24.546975																			

$	13-Dec-2018	20:54:53.920	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.609916	31.150000	174.500000																																

$	13-Dec-2018	20:54:54.032	AB Dec Buoycy Fast	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3458267

$	13-Dec-2018	20:54:54.338	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.616331	31.150000	174.500000																																

$	13-Dec-2018	20:54:55.241	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	138.616130	31.150000	174.500000																																

$	13-Dec-2018	20:54:55.450	AB Dec Buoycy Fast	SBE41 Message						   -0.13  	-0.130000	-0.113675	0.001227	0.006667	0.005000	0.000068	3.000000																							

$	13-Dec-2018	20:54:56.367	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	138.601892	31.150000	174.500000																																

$	13-Dec-2018	20:54:57.241	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	138.616852	31.150000	174.500000																																

$	13-Dec-2018	20:54:58.242	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	138.628267	31.150000	174.500000																																

$	13-Dec-2018	20:54:58.451	AB Dec Buoycy Fast	SBE41 Message						    1.47  	1.470000	-0.109613	0.001209	-0.533333	-0.263333	0.000077	3.000000																							

$	13-Dec-2018	20:54:59.269	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.470000	138.640821	31.150000	174.500000																																

$	13-Dec-2018	20:55:00.243	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.470000	139.057122	31.150000	174.500000																																

$	13-Dec-2018	20:55:01.243	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.470000	139.197126	31.150000	174.500000																																

$	13-Dec-2018	20:55:02.080	AB Dec Buoycy Fast	AB Decreasing Buoyancy Fast Exiting: Depth > pressure threshold

$	13-Dec-2018	20:55:01.450	AB Dec Buoycy Fast	SBE41 Message						    1.48  	1.480000	-0.103884	0.000763	-0.003333	-0.268333	0.000077	3.000000																							

$	13-Dec-2018	20:55:02.414	AB Dec Buoycy Fast	Normal State Exit

$	13-Dec-2018	20:55:02.418	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.480000	139.496610	31.150000	174.500000																																

$	13-Dec-2018	20:55:03.041	Descend	State Entry

$	13-Dec-2018	20:55:03.047	Descend	Starting valve open

$	13-Dec-2018	20:55:03.455	Descend	RecMode true, PID On, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.480000	139.741458	31.150000	174.500000																																

$	13-Dec-2018	20:55:04.245	Descend	RecMode true, PID On, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.480000	139.830723	31.150000	174.500000																																

$	13-Dec-2018	20:55:04.451	Descend	Vel PID Values																		-0.200000	0.300000	0.030337	0.030337	-0.001106	-26.516855	-26.516855	-217226.000000	3.000000										

$	13-Dec-2018	20:55:04.451	Descend	SBE41 Message						    0.58  	0.580000	-0.067051	0.000333	0.300000	0.148333	0.000031	3.000000																							

$	13-Dec-2018	20:55:05.584	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.580000	139.819697	31.150000	174.500000																																

$	13-Dec-2018	20:55:06.245	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.580000	139.848046	31.150000	174.500000																																

$	13-Dec-2018	20:55:07.245	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.580000	140.113056	31.150000	174.500000																																

$	13-Dec-2018	20:55:07.451	Descend	Vel PID Values																		-0.200000	0.003333	0.044650	0.014313	-0.002280	-23.389769	-23.389769	-191608.000000	3.000000										

$	13-Dec-2018	20:55:07.451	Descend	SBE41 Message						    0.57  	0.570000	0.088959	0.000005	0.003333	0.151667	-0.000207	3.000000																							

$	13-Dec-2018	20:55:08.585	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.570000	140.318476	31.150000	174.500000																																

$	13-Dec-2018	20:55:09.246	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.570000	140.659399	31.150000	174.500000																																

$	13-Dec-2018	20:55:10.246	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.570000	140.802465	31.150000	174.500000																																

$	13-Dec-2018	20:55:10.451	Descend	Vel PID Values																		-0.200000	0.003333	0.048512	0.003863	-0.003473	-20.913331	-20.913331	-171322.000000	3.000000										

$	13-Dec-2018	20:55:10.451	Descend	SBE41 Message						    0.56  	0.560000	0.422636	-0.003954	0.003333	0.003333	-0.000851	3.000000																							

$	13-Dec-2018	20:55:11.586	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.560000	141.016200	31.150000	174.500000																																

$	13-Dec-2018	20:55:12.246	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.560000	141.179182	31.150000	174.500000																																

$	13-Dec-2018	20:55:13.247	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.560000	141.306996	31.150000	174.500000																																

$	13-Dec-2018	20:55:13.450	Descend	Vel PID Values																		-0.200000	-0.043333	0.041395	-0.007118	-0.004631	-17.416995	-17.416995	-142680.000000	3.000000										

$	13-Dec-2018	20:55:13.450	Descend	SBE41 Message						    0.69  	0.690000	0.793857	-0.019482	-0.043333	-0.020000	-0.001929	3.000000																							

$	13-Dec-2018	20:55:14.584	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.690000	141.482867	31.150000	174.500000																																

$	13-Dec-2018	20:55:15.246	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.690000	141.697057	31.150000	174.500000																																

$	13-Dec-2018	20:55:16.246	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.690000	141.814619	31.150000	174.500000																																

$	13-Dec-2018	20:55:16.451	Descend	Vel PID Values																		-0.200000	-0.180000	0.015008	-0.026387	-0.005664	-10.168736	-10.168736	-83302.000000	3.000000										

$	13-Dec-2018	20:55:16.451	Descend	SBE41 Message						    1.23  	1.230000	0.951711	-0.048347	-0.180000	-0.111667	-0.003152	3.000000																							

$	13-Dec-2018	20:55:17.587	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.230000	141.972534	31.150000	174.500000																																

$	13-Dec-2018	20:55:18.247	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.230000	142.099693	31.150000	174.500000																																

$	13-Dec-2018	20:55:19.247	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.230000	142.131463	31.150000	174.500000																																

$	13-Dec-2018	20:55:19.450	Descend	Vel PID Values																		-0.200000	-0.003333	-0.001671	-0.016679	-0.006616	-11.424287	-11.424287	-93587.000000	3.000000										

$	13-Dec-2018	20:55:19.450	Descend	SBE41 Message						    1.24  	1.240000	0.855467	-0.076590	-0.003333	-0.091667	-0.004188	3.000000																							

$	13-Dec-2018	20:55:20.587	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.240000	142.241389	31.150000	174.500000																																

$	13-Dec-2018	20:55:21.248	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.240000	142.372780	31.150000	174.500000																																

$	13-Dec-2018	20:55:22.249	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.240000	142.468348	31.150000	174.500000																																

$	13-Dec-2018	20:55:22.451	Descend	Vel PID Values																		-0.200000	-0.003333	-0.011209	-0.009538	-0.007522	-12.566344	-12.566344	-102943.000000	3.000000										

$	13-Dec-2018	20:55:22.451	Descend	SBE41 Message						    1.25  	1.250000	0.712583	-0.084060	-0.003333	-0.003333	-0.004984	3.000000																							

$	13-Dec-2018	20:55:23.589	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.250000	142.555341	31.150000	174.500000																																

$	13-Dec-2018	20:55:24.250	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.250000	142.712168	31.150000	174.500000																																

$	13-Dec-2018	20:55:25.250	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.250000	142.791077	31.150000	174.500000																																

$	13-Dec-2018	20:55:25.450	Descend	Vel PID Values																		-0.200000	-0.406667	-0.056558	-0.045349	-0.008210	0.610079	0.610079	4997.000000	3.000000										

$	13-Dec-2018	20:55:25.450	Descend	SBE41 Message						    2.47  	2.470000	0.703921	-0.063305	-0.406667	-0.205000	-0.005716	3.000000																							

$	13-Dec-2018	20:55:26.589	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	2.470000	142.875448	31.150000	174.500000																																

$	13-Dec-2018	20:55:27.251	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	2.470000	143.004626	31.150000	174.500000																																

$	13-Dec-2018	20:55:28.251	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	2.470000	142.996341	31.150000	174.500000																																

$	13-Dec-2018	20:55:28.449	Descend	Vel PID Values																		-0.200000	-0.090000	-0.085416	-0.028859	-0.008760	-1.479283	-1.479283	-12118.000000	3.000000										

$	13-Dec-2018	20:55:28.449	Descend	SBE41 Message						    2.74  	2.740000	0.842833	-0.026225	-0.090000	-0.248333	-0.006572	3.000000																							

$	13-Dec-2018	20:55:29.588	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	2.740000	143.025123	31.150000	174.500000																																

$	13-Dec-2018	20:55:30.251	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	2.740000	142.994113	31.150000	174.500000																																

$	13-Dec-2018	20:55:31.251	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	2.740000	143.011890	31.150000	174.500000																																

$	13-Dec-2018	20:55:31.450	Descend	Vel PID Values																		-0.200000	-0.300000	-0.123329	-0.037912	-0.009128	3.967426	3.967426	32501.000000	3.000000										

$	13-Dec-2018	20:55:31.450	Descend	SBE41 Message						    3.64  	3.640000	1.059629	0.003849	-0.300000	-0.195000	-0.007640	3.000000																							

$	13-Dec-2018	20:55:32.592	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	3.640000	143.011957	31.150000	174.500000																																

$	13-Dec-2018	20:55:33.252	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	3.640000	143.018395	31.150000	174.500000																																

$	13-Dec-2018	20:55:34.253	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	3.640000	143.032320	31.150000	174.500000																																

$	13-Dec-2018	20:55:34.450	Descend	Vel PID Values																		-0.200000	-0.090000	-0.141257	-0.017929	-0.009410	0.072420	0.072420	593.000000	3.000000										

$	13-Dec-2018	20:55:34.450	Descend	SBE41 Message						    3.91  	3.910000	1.332814	0.007861	-0.090000	-0.195000	-0.008978	3.000000																							

$	13-Dec-2018	20:55:35.594	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	3.910000	143.013947	31.150000	174.500000																																

$	13-Dec-2018	20:55:36.253	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	3.910000	143.009655	31.150000	174.500000																																

$	13-Dec-2018	20:55:37.253	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	3.910000	143.034875	31.150000	174.500000																																

$	13-Dec-2018	20:55:37.451	Descend	Vel PID Values																		-0.200000	-0.313333	-0.168730	-0.027473	-0.009560	4.815216	4.815216	39446.000000	3.000000										

$	13-Dec-2018	20:55:37.451	Descend	SBE41 Message						    4.85  	4.850000	1.721688	-0.015148	-0.313333	-0.201667	-0.010712	3.000000																							

$	13-Dec-2018	20:55:38.593	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	4.850000	143.044971	31.150000	174.500000																																

$	13-Dec-2018	20:55:39.254	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	4.850000	143.025391	31.150000	174.500000																																

$	13-Dec-2018	20:55:40.254	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	4.850000	143.044740	31.150000	174.500000																																

$	13-Dec-2018	20:55:40.450	Descend	Vel PID Values																		-0.200000	-0.086667	-0.175866	-0.007136	-0.009676	-0.037376	-0.037376	-306.000000	3.000000										

$	13-Dec-2018	20:55:40.450	Descend	SBE41 Message						    5.11  	5.110000	2.255277	-0.051204	-0.086667	-0.200000	-0.013000	3.000000																							

$	13-Dec-2018	20:55:41.613	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	5.110000	143.040597	31.150000	174.500000																																

$	13-Dec-2018	20:55:42.253	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	5.110000	143.046163	31.150000	174.500000																																

$	13-Dec-2018	20:55:43.253	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	5.110000	143.036485	31.150000	174.500000																																

$	13-Dec-2018	20:55:43.451	Descend	Vel PID Values																		-0.200000	-0.296667	-0.192091	-0.016225	-0.009714	3.684170	3.684170	30180.000000	3.000000										

$	13-Dec-2018	20:55:43.451	Descend	SBE41 Message						    6.00  	6.000000	2.866166	-0.088087	-0.296667	-0.191667	-0.015903	3.000000																							

$	13-Dec-2018	20:55:44.594	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	6.000000	143.039927	31.150000	174.500000																																

$	13-Dec-2018	20:55:45.254	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	6.000000	143.037327	31.150000	174.500000																																

$	13-Dec-2018	20:55:46.254	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	6.000000	143.025994	31.150000	174.500000																																

$	13-Dec-2018	20:55:46.450	Descend	Vel PID Values																		-0.200000	-0.140000	-0.195938	-0.003847	-0.009734	0.691308	0.691308	5663.000000	3.000000										

$	13-Dec-2018	20:55:46.450	Descend	SBE41 Message						    6.42  	6.420000	3.479546	-0.122934	-0.140000	-0.218333	-0.019381	3.000000																							

$	13-Dec-2018	20:55:47.595	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	6.420000	143.041506	31.150000	174.500000																																

$	13-Dec-2018	20:55:48.255	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	6.420000	143.042326	31.150000	174.500000																																

$	13-Dec-2018	20:55:49.254	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	6.420000	143.047035	31.150000	174.500000																																

$	13-Dec-2018	20:55:49.451	Descend	Vel PID Values																		-0.200000	-0.193333	-0.197836	-0.001898	-0.009744	0.323305	0.323305	2648.000000	3.000000										

$	13-Dec-2018	20:55:49.451	Descend	SBE41 Message						    7.00  	7.000000	4.079762	-0.155867	-0.193333	-0.166667	-0.023374	3.000000																							

$	13-Dec-2018	20:55:50.596	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	7.000000	143.041320	31.150000	174.500000																																

$	13-Dec-2018	20:55:51.255	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	7.000000	143.034428	31.150000	174.500000																																

$	13-Dec-2018	20:55:52.256	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	7.000000	143.053308	31.150000	174.500000																																

$	13-Dec-2018	20:55:52.450	Descend	Vel PID Values																		-0.200000	-0.233333	-0.202492	-0.004656	-0.009732	1.431197	1.431197	11724.000000	3.000000										

$	13-Dec-2018	20:55:52.450	Descend	SBE41 Message						    7.70  	7.700000	4.676749	-0.183972	-0.233333	-0.213333	-0.027835	3.000000																							

$	13-Dec-2018	20:55:53.593	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	7.700000	143.034719	31.150000	174.500000																																

$	13-Dec-2018	20:55:54.255	Descend	PTH Message														780.015381	23.750000	51.941437	24.600601																			

$	13-Dec-2018	20:55:54.457	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	7.700000	143.044747	31.675000	118.000000																																

$	13-Dec-2018	20:55:55.255	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	7.700000	143.026561	31.675000	118.000000																																

$	13-Dec-2018	20:55:55.451	Descend	Vel PID Values																		-0.200000	-0.196667	-0.204519	-0.002027	-0.009710	0.892186	0.892186	7308.000000	3.000000										

$	13-Dec-2018	20:55:55.451	Descend	SBE41 Message						    8.29  	8.290000	5.274153	-0.202290	-0.196667	-0.215000	-0.032721	3.000000																							

$	13-Dec-2018	20:55:56.594	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	8.290000	143.029995	31.675000	118.000000																																

$	13-Dec-2018	20:55:57.256	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	8.290000	143.035412	31.675000	118.000000																																

$	13-Dec-2018	20:55:58.256	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	8.290000	143.030800	31.675000	118.000000																																

$	13-Dec-2018	20:55:58.450	Descend	Vel PID Values																		-0.200000	-0.180000	-0.203178	0.001341	-0.009695	-0.113057	-0.113057	-926.000000	3.000000										

$	13-Dec-2018	20:55:58.450	Descend	SBE41 Message						    8.83  	8.830000	5.868957	-0.208953	-0.180000	-0.188333	-0.037985	3.000000																							

$	13-Dec-2018	20:55:59.601	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	8.830000	143.029459	31.675000	118.000000																																

$	13-Dec-2018	20:56:00.257	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	8.830000	143.013239	31.675000	118.000000																																

$	13-Dec-2018	20:56:01.257	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	8.830000	143.055663	31.675000	118.000000																																

$	13-Dec-2018	20:56:01.451	Descend	Vel PID Values																		-0.200000	-0.210000	-0.203114	0.000063	-0.009680	0.222543	0.222543	1823.000000	3.000000										

$	13-Dec-2018	20:56:01.451	Descend	SBE41 Message						    9.46  	9.460000	6.460087	-0.208120	-0.210000	-0.195000	-0.043578	3.000000																							

$	13-Dec-2018	20:56:02.598	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	9.460000	143.055454	31.675000	118.000000																																

$	13-Dec-2018	20:56:03.258	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	9.460000	143.056124	31.675000	118.000000																																

$	13-Dec-2018	20:56:04.258	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	9.460000	143.029079	31.675000	118.000000																																

$	13-Dec-2018	20:56:04.450	Descend	Vel PID Values																		-0.200000	-0.200000	-0.202764	0.000351	-0.009667	0.117944	0.117944	966.000000	3.000000										

$	13-Dec-2018	20:56:04.450	Descend	SBE41 Message						   10.06  	10.060000	7.055947	-0.205832	-0.200000	-0.205000	-0.049463	3.000000																							

$	13-Dec-2018	20:56:05.599	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	10.060000	143.038787	31.675000	118.000000																																

$	13-Dec-2018	20:56:06.259	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	10.060000	143.022209	31.675000	118.000000																																

$	13-Dec-2018	20:56:07.260	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	10.060000	143.035203	31.675000	118.000000																																

$	13-Dec-2018	20:56:07.452	Descend	Vel PID Values																		-0.200000	-0.250000	-0.207344	-0.004580	-0.009632	1.799086	1.799086	14738.000000	3.000000										

$	13-Dec-2018	20:56:07.452	Descend	SBE41 Message						   10.81  	10.810000	7.660781	-0.204809	-0.250000	-0.225000	-0.055607	3.000000																							

$	13-Dec-2018	20:56:08.598	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	10.810000	143.045731	31.675000	118.000000																																

$	13-Dec-2018	20:56:09.261	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	10.810000	143.031463	31.675000	118.000000																																

$	13-Dec-2018	20:56:10.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	10.810000	143.023625	31.675000	118.000000																																

$	13-Dec-2018	20:56:10.451	Descend	Vel PID Values																		-0.200000	-0.196666	-0.208837	-0.001493	-0.009589	1.095489	1.095489	8974.000000	3.000000										

$	13-Dec-2018	20:56:10.451	Descend	SBE41 Message						   11.40  	11.400000	8.264532	-0.204910	-0.196666	-0.223333	-0.061964	3.000000																							

$	13-Dec-2018	20:56:11.601	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	11.400000	143.026434	31.675000	118.000000																																

$	13-Dec-2018	20:56:12.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	11.400000	143.033326	31.675000	118.000000																																

$	13-Dec-2018	20:56:13.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	11.400000	143.035457	31.675000	118.000000																																

$	13-Dec-2018	20:56:13.452	Descend	Vel PID Values																		-0.200000	-0.190000	-0.207771	0.001066	-0.009552	0.327820	0.327820	2685.000000	3.000000										

$	13-Dec-2018	20:56:13.452	Descend	SBE41 Message						   11.97  	11.970000	8.864493	-0.205486	-0.190000	-0.193333	-0.068486	3.000000																							

$	13-Dec-2018	20:56:14.602	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	11.970000	143.016368	31.675000	118.000000																																

$	13-Dec-2018	20:56:15.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	11.970000	143.034942	31.675000	118.000000																																

$	13-Dec-2018	20:56:16.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	11.970000	143.027186	31.675000	118.000000																																

$	13-Dec-2018	20:56:16.451	Descend	Vel PID Values																		-0.200000	-0.196667	-0.206049	0.001722	-0.009523	0.015243	0.015243	124.000000	3.000000										

$	13-Dec-2018	20:56:16.451	Descend	SBE41 Message						   12.56  	12.560000	9.476031	-0.206089	-0.196667	-0.193333	-0.075143	3.000000																							

$	13-Dec-2018	20:56:17.605	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	12.560000	143.045738	31.675000	118.000000																																

$	13-Dec-2018	20:56:18.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	12.560000	143.052809	31.675000	118.000000																																

$	13-Dec-2018	20:56:19.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	12.560000	143.044986	31.675000	118.000000																																

$	13-Dec-2018	20:56:19.452	Descend	Vel PID Values																		-0.200000	-0.203333	-0.204807	0.001242	-0.009500	0.043875	0.043875	359.000000	3.000000										

$	13-Dec-2018	20:56:19.452	Descend	SBE41 Message						   13.17  	13.170000	10.108788	-0.206867	-0.203333	-0.200000	-0.081919	3.000000																							

$	13-Dec-2018	20:56:20.600	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	13.170000	143.053807	31.675000	118.000000																																

$	13-Dec-2018	20:56:21.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	13.170000	143.068090	31.675000	118.000000																																

$	13-Dec-2018	20:56:22.261	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	13.170000	143.047690	31.675000	118.000000																																

$	13-Dec-2018	20:56:22.452	Descend	Vel PID Values																		-0.200000	-0.206667	-0.204298	0.000510	-0.009479	0.198390	0.198390	1625.000000	3.000000										

$	13-Dec-2018	20:56:22.452	Descend	SBE41 Message						   13.79  	13.790000	10.748578	-0.208467	-0.206667	-0.205000	-0.088777	3.000000																							

$	13-Dec-2018	20:56:23.600	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	13.790000	143.035628	31.675000	118.000000																																

$	13-Dec-2018	20:56:24.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	13.790000	143.052749	31.675000	118.000000																																

$	13-Dec-2018	20:56:25.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	13.790000	143.047422	31.675000	118.000000																																

$	13-Dec-2018	20:56:25.451	Descend	Vel PID Values																		-0.200000	-0.216667	-0.205262	-0.000964	-0.009454	0.668672	0.668672	5477.000000	3.000000										

$	13-Dec-2018	20:56:25.451	Descend	SBE41 Message						   14.44  	14.440000	11.372635	-0.211071	-0.216667	-0.211667	-0.095652	3.000000																							

$	13-Dec-2018	20:56:26.601	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	14.440000	143.047385	31.675000	118.000000																																

$	13-Dec-2018	20:56:27.261	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	14.440000	143.040732	31.675000	118.000000																																

$	13-Dec-2018	20:56:28.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	14.440000	143.017553	31.675000	118.000000																																

$	13-Dec-2018	20:56:28.452	Descend	Vel PID Values																		-0.200000	-0.206667	-0.205946	-0.000684	-0.009425	0.648594	0.648594	5313.000000	3.000000										

$	13-Dec-2018	20:56:28.452	Descend	SBE41 Message						   15.06  	15.060000	11.976358	-0.213899	-0.206667	-0.211667	-0.102478	3.000000																							

$	13-Dec-2018	20:56:29.602	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	15.060000	143.031225	31.675000	118.000000																																

$	13-Dec-2018	20:56:30.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	15.060000	143.050231	31.675000	118.000000																																

$	13-Dec-2018	20:56:31.263	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	15.060000	143.042915	31.675000	118.000000																																

$	13-Dec-2018	20:56:31.451	Descend	Vel PID Values																		-0.200000	-0.193333	-0.205055	0.000891	-0.009401	0.157294	0.157294	1288.000000	3.000000										

$	13-Dec-2018	20:56:31.451	Descend	SBE41 Message						   15.64  	15.640000	12.574790	-0.215567	-0.193333	-0.200000	-0.109634	3.000000																							

$	13-Dec-2018	20:56:32.603	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	15.640000	143.036917	31.675000	118.000000																																

$	13-Dec-2018	20:56:33.262	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	15.640000	143.035211	31.675000	118.000000																																

$	13-Dec-2018	20:56:34.263	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	15.640000	143.039420	31.675000	118.000000																																

$	13-Dec-2018	20:56:34.452	Descend	Vel PID Values																		-0.200000	-0.200000	-0.204043	0.001012	-0.009382	0.044200	0.044200	362.000000	3.000000										

$	13-Dec-2018	20:56:34.452	Descend	SBE41 Message						   16.24  	16.240000	13.182523	-0.214953	-0.200000	-0.196667	-0.116739	3.000000																							

$	13-Dec-2018	20:56:35.602	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	16.240000	143.036440	31.675000	118.000000																																

$	13-Dec-2018	20:56:36.264	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	16.240000	143.032581	31.675000	118.000000																																

$	13-Dec-2018	20:56:37.263	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	16.240000	143.032342	31.675000	118.000000																																

$	13-Dec-2018	20:56:37.450	Descend	Vel PID Values																		-0.200000	-0.196667	-0.202728	0.001314	-0.009369	-0.141597	-0.141597	-1159.000000	3.000000										

$	13-Dec-2018	20:56:37.450	Descend	SBE41 Message						   16.83  	16.830000	13.801712	-0.212407	-0.196667	-0.198333	-0.123767	3.000000																							

$	13-Dec-2018	20:56:38.603	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	16.830000	143.029690	31.675000	118.000000																																

$	13-Dec-2018	20:56:39.279	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	16.830000	143.036492	31.675000	118.000000																																

$	13-Dec-2018	20:56:40.280	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	16.830000	143.023036	31.675000	118.000000																																

$	13-Dec-2018	20:56:40.452	Descend	Vel PID Values																		-0.200000	-0.213333	-0.203062	-0.000334	-0.009354	0.324690	0.324690	2659.000000	3.000000										

$	13-Dec-2018	20:56:40.452	Descend	SBE41 Message						   17.47  	17.469999	14.423982	-0.209912	-0.213333	-0.205000	-0.130683	3.000000																							

$	13-Dec-2018	20:56:41.620	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	17.469999	143.036880	31.675000	118.000000																																

$	13-Dec-2018	20:56:42.279	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	17.469999	143.048786	31.675000	118.000000																																

$	13-Dec-2018	20:56:43.279	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	17.469999	143.026896	31.675000	118.000000																																

$	13-Dec-2018	20:56:43.451	Descend	Vel PID Values																		-0.200000	-0.203334	-0.203278	-0.000215	-0.009338	0.310191	0.310191	2541.000000	3.000000										

$	13-Dec-2018	20:56:43.451	Descend	SBE41 Message						   18.08  	18.080000	15.038697	-0.209341	-0.203334	-0.208333	-0.137436	3.000000																							

$	13-Dec-2018	20:56:44.620	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	18.080000	143.034711	31.675000	118.000000																																

$	13-Dec-2018	20:56:45.279	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	18.080000	143.060230	31.675000	118.000000																																

$	13-Dec-2018	20:56:46.279	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	18.080000	143.027313	31.675000	118.000000																																

$	13-Dec-2018	20:56:46.452	Descend	Vel PID Values																		-0.200000	-0.203334	-0.203404	-0.000126	-0.009322	0.296707	0.296707	2430.000000	3.000000										

$	13-Dec-2018	20:56:46.452	Descend	SBE41 Message						   18.69  	18.690001	15.642954	-0.210587	-0.203334	-0.203334	-0.143973	3.000000																							

$	13-Dec-2018	20:56:47.619	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	18.690001	143.026799	31.675000	118.000000																																

$	13-Dec-2018	20:56:48.280	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	18.690001	143.058062	31.675000	118.000000																																

$	13-Dec-2018	20:56:49.280	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	18.690001	143.033758	31.675000	118.000000																																

$	13-Dec-2018	20:56:49.451	Descend	Vel PID Values																		-0.200000	-0.210000	-0.204142	-0.000738	-0.009302	0.518850	0.518850	4250.000000	3.000000										

$	13-Dec-2018	20:56:49.451	Descend	SBE41 Message						   19.32  	19.320000	16.243807	-0.211846	-0.210000	-0.206667	-0.150251	3.000000																							

$	13-Dec-2018	20:56:50.620	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	19.320000	143.028334	31.675000	118.000000																																

$	13-Dec-2018	20:56:51.281	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	19.320000	143.041790	31.675000	118.000000																																

$	13-Dec-2018	20:56:52.281	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	19.320000	143.039465	31.675000	118.000000																																

$	13-Dec-2018	20:56:52.451	Descend	Vel PID Values																		-0.200000	-0.230000	-0.207172	-0.003029	-0.009268	1.372285	1.372285	11241.000000	3.000000										

$	13-Dec-2018	20:56:52.451	Descend	SBE41 Message						   20.01  	20.010000	16.849800	-0.211677	-0.230000	-0.220000	-0.156243	3.000000																							

$	13-Dec-2018	20:56:53.622	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	20.010000	143.013991	31.675000	118.000000																																

$	13-Dec-2018	20:56:54.281	Descend	PTH Message														784.648926	23.833333	51.834625	24.632776																			

$	13-Dec-2018	20:56:54.484	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	20.010000	143.023491	31.725000	117.500000																																

$	13-Dec-2018	20:56:55.281	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	20.010000	143.039033	31.725000	117.500000																																

$	13-Dec-2018	20:56:55.451	Descend	Vel PID Values																		-0.200000	-0.206666	-0.208822	-0.001651	-0.009225	1.136758	1.136758	9312.000000	3.000000										

$	13-Dec-2018	20:56:55.451	Descend	SBE41 Message						   20.63  	20.629999	17.462956	-0.210307	-0.206666	-0.218333	-0.161926	3.000000																							

$	13-Dec-2018	20:56:56.622	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	20.629999	143.041119	31.725000	117.500000																																

$	13-Dec-2018	20:56:57.281	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	20.629999	143.038213	31.725000	117.500000																																

$	13-Dec-2018	20:56:58.281	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	20.629999	143.020436	31.725000	117.500000																																

$	13-Dec-2018	20:56:58.451	Descend	Vel PID Values																		-0.200000	-0.190001	-0.207847	0.000976	-0.009188	0.358263	0.358263	2934.000000	3.000000										

$	13-Dec-2018	20:56:58.451	Descend	SBE41 Message						   21.20  	21.200001	18.081374	-0.208991	-0.190001	-0.198333	-0.167268	3.000000																							

$	13-Dec-2018	20:56:59.621	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	21.200001	143.038347	31.725000	117.500000																																

$	13-Dec-2018	20:57:00.281	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	21.200001	143.053651	31.725000	117.500000																																

$	13-Dec-2018	20:57:01.282	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	21.200001	143.035710	31.725000	117.500000																																

$	13-Dec-2018	20:57:01.452	Descend	Vel PID Values																		-0.200000	-0.193333	-0.205831	0.002016	-0.009160	-0.080302	-0.080302	-657.000000	3.000000										

$	13-Dec-2018	20:57:01.452	Descend	SBE41 Message						   21.78  	21.780001	18.706780	-0.208748	-0.193333	-0.191667	-0.172243	3.000000																							

$	13-Dec-2018	20:57:02.622	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	21.780001	143.034019	31.725000	117.500000																																

$	13-Dec-2018	20:57:03.282	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	21.780001	143.050462	31.725000	117.500000																																

$	13-Dec-2018	20:57:04.282	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	21.780001	143.063053	31.725000	117.500000																																

$	13-Dec-2018	20:57:04.451	Descend	Vel PID Values																		-0.200000	-0.203333	-0.204446	0.001385	-0.009138	-0.022874	-0.022874	-187.000000	3.000000										

$	13-Dec-2018	20:57:04.451	Descend	SBE41 Message						   22.39  	22.389999	19.341364	-0.209863	-0.203333	-0.198333	-0.176862	3.000000																							

$	13-Dec-2018	20:57:05.622	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	22.389999	143.067710	31.725000	117.500000																																

$	13-Dec-2018	20:57:06.283	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	22.389999	143.046543	31.725000	117.500000																																

$	13-Dec-2018	20:57:07.284	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	22.389999	143.050887	31.725000	117.500000																																

$	13-Dec-2018	20:57:07.451	Descend	Vel PID Values																		-0.200000	-0.216667	-0.204903	-0.000458	-0.009115	0.505193	0.505193	4138.000000	3.000000										

$	13-Dec-2018	20:57:07.451	Descend	SBE41 Message						   23.04  	23.040001	19.976724	-0.212055	-0.216667	-0.210000	-0.181242	3.000000																							

$	13-Dec-2018	20:57:08.625	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	23.040001	143.056877	31.725000	117.500000																																

$	13-Dec-2018	20:57:09.284	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	23.040001	143.052720	31.725000	117.500000																																

$	13-Dec-2018	20:57:10.285	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	23.040001	143.032849	31.725000	117.500000																																

$	13-Dec-2018	20:57:10.452	Descend	Vel PID Values																		-0.200000	-0.203333	-0.205002	-0.000098	-0.009091	0.417247	0.417247	3418.000000	3.000000										

$	13-Dec-2018	20:57:10.452	Descend	SBE41 Message						   23.65  	23.650000	20.597742	-0.214606	-0.203333	-0.210000	-0.185564	3.000000																							

$	13-Dec-2018	20:57:11.625	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	23.650000	143.046856	31.725000	117.500000																																

$	13-Dec-2018	20:57:12.285	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	23.650000	143.074922	31.725000	117.500000																																

$	13-Dec-2018	20:57:13.285	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	23.650000	143.048584	31.725000	117.500000																																

$	13-Dec-2018	20:57:13.452	Descend	Vel PID Values																		-0.200000	-0.193333	-0.203877	0.001125	-0.009072	0.001150	0.001150	9.000000	3.000000										

$	13-Dec-2018	20:57:13.452	Descend	SBE41 Message						   24.23  	24.230000	21.201171	-0.216402	-0.193333	-0.198333	-0.189836	3.000000																							

$	13-Dec-2018	20:57:14.626	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.230000	143.052764	31.725000	117.500000																																

$	13-Dec-2018	20:57:15.286	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.230000	143.062793	31.725000	117.500000																																

$	13-Dec-2018	20:57:16.286	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.230000	143.053718	31.725000	117.500000																																

$	13-Dec-2018	20:57:16.451	Descend	Vel PID Values																		-0.200000	-0.200000	-0.202853	0.001024	-0.009058	-0.053862	-0.053862	-441.000000	3.000000										

$	13-Dec-2018	20:57:16.451	Descend	SBE41 Message						   24.83  	24.830000	21.800393	-0.216435	-0.200000	-0.196667	-0.193765	3.000000																							

$	13-Dec-2018	20:57:17.626	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.830000	143.042073	31.725000	117.500000																																

$	13-Dec-2018	20:57:18.287	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.830000	143.044740	31.725000	117.500000																																

$	13-Dec-2018	20:57:19.287	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.830000	143.047340	31.725000	117.500000																																

$	13-Dec-2018	20:57:19.451	Descend	Vel PID Values																		-0.200000	-0.210000	-0.203001	-0.000147	-0.009044	0.270313	0.270313	2214.000000	3.000000										

$	13-Dec-2018	20:57:19.451	Descend	SBE41 Message						   25.46  	25.459999	22.408236	-0.214577	-0.210000	-0.205000	-0.197008	3.000000																							

$	13-Dec-2018	20:57:20.627	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.459999	143.065453	31.725000	117.500000																																

$	13-Dec-2018	20:57:21.289	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.459999	143.040106	31.725000	117.500000																																

$	13-Dec-2018	20:57:22.288	Descend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.459999	143.042810	31.725000	117.500000																																

$	13-Dec-2018	20:57:22.452	Descend	Vel PID Values																		-0.200000	-0.046667	-0.187274	0.015726	-0.009105	-5.220731	-5.220731	-42768.000000	3.000000										

$	13-Dec-2018	20:57:22.452	Descend	SBE41 Message						   25.60  	25.600000	23.022629	-0.211816	-0.046667	-0.128333	-0.199468	3.000000																							

$	13-Dec-2018	20:57:23.629	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.600000	143.055394	31.725000	117.500000																																

$	13-Dec-2018	20:57:24.288	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.600000	143.049695	31.725000	117.500000																																

$	13-Dec-2018	20:57:25.288	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.600000	143.051527	31.725000	117.500000																																

$	13-Dec-2018	20:57:25.451	Descend	Vel PID Values																		-0.200000	0.003333	-0.159165	0.028110	-0.009301	-10.771905	-10.771905	-88243.000000	3.000000										

$	13-Dec-2018	20:57:25.451	Descend	SBE41 Message						   25.59  	25.590000	23.632542	-0.209628	0.003333	-0.021667	-0.201267	3.000000																							

$	13-Dec-2018	20:57:26.630	Descend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.590000	143.070526	31.725000	117.500000																																

$	13-Dec-2018	20:57:27.587	Descend	Starting valve close

$	13-Dec-2018	20:57:27.591	Descend	Descend glide on

$	13-Dec-2018	20:57:27.994	Descend	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.590000	143.058538	31.725000	117.500000																																

$	13-Dec-2018	20:57:28.107	Descend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0206825

$	13-Dec-2018	20:57:28.412	Descend	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.590000	143.038347	31.725000	117.500000																																

$	13-Dec-2018	20:57:29.113	Descend	Bottom detected based on Platform Velocity near zero

$	13-Dec-2018	20:57:28.522	Descend	SBE41 Message						   25.58  	25.580000	24.224995	-0.208968	0.003333	0.003333	-0.202515	3.000000																							

$	13-Dec-2018	20:57:29.550	Descend	Normal State Exit

$	13-Dec-2018	20:57:29.554	Descend	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.580000	143.047392	31.725000	117.500000																																

$	13-Dec-2018	20:57:30.112	Anchor	State Entry

$	13-Dec-2018	20:57:30.218	Anchor	Starting valve close

$	13-Dec-2018	20:57:30.224	Anchor	Powering up MSC

$	13-Dec-2018	20:57:30.325	Anchor	Powering up FLBB

$	13-Dec-2018	20:57:31.927	Anchor	Sending FLBB stop command

$	13-Dec-2018	20:57:33.432	Anchor	Sending FLBB pkt command: $pkt 1  

$	13-Dec-2018	20:57:34.536	Anchor	Sending FLBB ave command: $ave 10  

$	13-Dec-2018	20:57:35.541	Anchor	Powering up 4330 Optode

$	13-Dec-2018	20:57:37.046	Anchor	Sending Optode Wakeup

$	13-Dec-2018	20:57:41.057	Anchor	Powering up OCR504

$	13-Dec-2018	20:57:41.169	Anchor	Starting anchor period = 00:04:00

$	13-Dec-2018	20:57:41.601	Anchor	Error in I2CPortBase.Execute

$	13-Dec-2018	20:57:42.907	Anchor	Error executing 2485 Transaction = 0

$	13-Dec-2018	20:57:43.008	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.580000	250.000000	31.725000	117.500000																																

$	13-Dec-2018	20:57:43.120	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:13.0073884

$	13-Dec-2018	20:57:43.232	Anchor	CTD post: 25.59	NaN	NaN

$	13-Dec-2018	20:57:31.452	Anchor	SBE41 Message						   25.59  	25.590000	24.766576	-0.209545	-0.003333	0.000000	-0.203257	3.000000																							

$	13-Dec-2018	20:57:43.452	Anchor	MSC: RX: 

$	13-Dec-2018	20:57:43.553	Anchor	MSC: RX: 

$	13-Dec-2018	20:57:43.558	Anchor	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	13-Dec-2018	20:57:43.758	Anchor	Sending CTD PTS

$	13-Dec-2018	20:57:43.762	Anchor	Sci Logger sample CTD pts

$	13-Dec-2018	20:57:43.870	Anchor	Sending Optode Do Sample

$	13-Dec-2018	20:57:43.971	Anchor	Sending Optode Wakeup

$	13-Dec-2018	20:57:34.452	Anchor	SBE41 Message						   25.57  	25.570000	25.191482	-0.209176	0.006667	0.001667	-0.203386	3.000000																							

$	13-Dec-2018	20:57:35.818	Anchor	Optode Message																												 %  								

$	13-Dec-2018	20:57:35.929	Anchor	Optode Message																												StartupInfo,4330,1532,Mode,AADI Smart Sensor Terminal Protocol,RS232 Protocol Version,3,Config Version,11  								

$	13-Dec-2018	20:57:44.524	Anchor	Optode post: StartupInfo,4330,1532,Mode,AADI Smart Sensor Terminal Protocol,RS232 Protocol Version,3,Config Version,11  

$	13-Dec-2018	20:57:44.530	Anchor	MSC: RX:   MBARI Serial Number : 0777 

$	13-Dec-2018	20:57:44.730	Anchor	Sci Logger sample Optode

$	13-Dec-2018	20:57:44.746	Anchor	Sci Logger sample pH and NO3

$	13-Dec-2018	20:57:44.945	Anchor	Sending FLBB run command

$	13-Dec-2018	20:57:44.949	Anchor	Sci Logger sample FLBB

$	13-Dec-2018	20:57:45.153	Anchor	Sending radiometer pollSample

$	13-Dec-2018	20:57:45.484	Anchor	Error in I2CPortBase.Execute

$	13-Dec-2018	20:57:45.586	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.570000	143.047392	31.725000	117.500000																																

$	13-Dec-2018	20:57:45.697	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.5704617

$	13-Dec-2018	20:57:45.703	Anchor	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	13-Dec-2018	20:57:45.807	Anchor	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	13-Dec-2018	20:57:37.451	Anchor	SBE41 Message						   25.20  	25.200001	25.448071	-0.203269	0.123333	0.065000	-0.202833	3.000000																							

$	13-Dec-2018	20:57:46.132	Anchor	MSC: RX:   CF Card: Size=256614400 Avail=99.09% 

$	13-Dec-2018	20:57:46.137	Anchor	MSC: RX:   CF2 Power Up  (GMT): Wed Feb  1 03:22:44 2012 

$	13-Dec-2018	20:57:46.241	Anchor	MSC: RX:   CF2 RTC Time  (GMT): Wed Feb  1 03:22:48 2012 

$	13-Dec-2018	20:57:46.442	Anchor	MSC: RX:   Adjusted Local Time: Tue Jan 31 19:22:48 2012 

$	13-Dec-2018	20:57:46.544	Anchor	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	13-Dec-2018	20:57:46.647	Anchor	MSC: RX:   RTC delta (CF2 - DS3234) : +0.00 secs. 

$	13-Dec-2018	20:57:46.652	Anchor	MSC: RX:   System Batt Voltage = 11.764 

$	13-Dec-2018	20:57:46.754	Anchor	MSC: RX:   System Load Current = 2.62e-02 

$	13-Dec-2018	20:57:38.196	Anchor	Optode Message																												!#  								

$	13-Dec-2018	20:57:47.067	Anchor	MSC: RX:   Housing Temperature = +22.28C = +72.10F 

$	13-Dec-2018	20:57:47.170	Anchor	MSC: RX:   Housing    Humidity =  55.1%  =  12.8C (DP) 

$	13-Dec-2018	20:57:47.474	Anchor	Sci Logger sample Radiometer

$	13-Dec-2018	20:57:48.473	Anchor	Error executing 2485 Transaction = 0

$	13-Dec-2018	20:57:48.575	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.200001	250.000000	31.725000	117.500000																																

$	13-Dec-2018	20:57:48.693	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9906639

$	13-Dec-2018	20:57:48.796	Anchor	MSC: RX:   Power Cycle   Count = 163 

$	13-Dec-2018	20:57:48.898	Anchor	MSC: RX:   System Reset  Count = 167 

$	13-Dec-2018	20:57:49.001	Anchor	MSC: RX:   System Error  Count = 66 

$	13-Dec-2018	20:57:49.103	Anchor	MSC: RX:   Last System   Error = -110 

$	13-Dec-2018	20:57:49.206	Anchor	MSC: RX:   Last Error     Time = Tue Jan 31 02:58:15 2012 

$	13-Dec-2018	20:57:49.212	Anchor	MSC: RX:   ISUS Error    Count = 1 

$	13-Dec-2018	20:57:49.314	Anchor	MSC: RX:   Last ISUS     Error = -202 

$	13-Dec-2018	20:57:49.416	Anchor	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	13-Dec-2018	20:57:49.616	Anchor	MSC: RX:   DURA Error    Count = 0 

$	13-Dec-2018	20:57:49.718	Anchor	MSC: RX:   Last DURA     Error = 0 

$	13-Dec-2018	20:57:49.820	Anchor	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	13-Dec-2018	20:57:49.923	Anchor	MSC: RX:   Fiberlite  Odometer = 100:12:10 = 360730 secs 

$	13-Dec-2018	20:57:49.929	Anchor	MSC: RX:   Fiberlite    Cycles = 254 

$	13-Dec-2018	20:57:50.035	Anchor	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	13-Dec-2018	20:57:50.235	Anchor	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	13-Dec-2018	20:57:50.337	Anchor	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	13-Dec-2018	20:57:50.643	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.200001	143.046081	31.725000	117.500000																																

$	13-Dec-2018	20:57:50.755	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0560014

$	13-Dec-2018	20:57:50.760	Anchor	MSC: RX:   There are 72 records in the error file! 

$	13-Dec-2018	20:57:50.961	Anchor	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	13-Dec-2018	20:57:39.232	Anchor	Optode Message																												#  								

$	13-Dec-2018	20:57:51.083	Anchor	MSC: RX:   Auto Shutdown in 10 hours at: Wed Feb  1 13:22:49 2012 

$	13-Dec-2018	20:57:51.283	Anchor	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	13-Dec-2018	20:57:40.099	Anchor	Optode Message																												#  								

$	13-Dec-2018	20:57:40.452	Anchor	SBE41 Message						   25.09  	25.090000	25.554266	-0.186266	0.036667	0.080000	-0.201611	3.000000																							

$	13-Dec-2018	20:57:51.525	Anchor	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	13-Dec-2018	20:57:51.749	Anchor	Radiometer post: Satlantic OCR-504 Multispectral Radiometer 

$	13-Dec-2018	20:57:51.851	Anchor	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	13-Dec-2018	20:57:51.862	Anchor	Radiometer Message																																	Firmware version: 5.1.0 - SatNet Type B 			

$	13-Dec-2018	20:57:51.972	Anchor	Radiometer Message																																	Idnstrument: SATFI4 			

$	13-Dec-2018	20:57:52.081	Anchor	Radiometer Message																																	S/N: 0287 			

$	13-Dec-2018	20:57:52.189	Anchor	Radiometer Message																																	Reset Source: Power 			

$	13-Dec-2018	20:57:52.394	Anchor	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	13-Dec-2018	20:57:52.504	Anchor	Radiometer Message																																	Initializing system. Please wait... 			

$	13-Dec-2018	20:57:52.717	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.090000	143.056013	31.725000	117.500000																																

$	13-Dec-2018	20:57:52.829	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0686639

$	13-Dec-2018	20:57:42.712	Anchor	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:57:43.864	Anchor	Unparsed SBE41 Message						S>pts  																														

$	13-Dec-2018	20:57:53.073	Anchor	Radiometer Message																																	Autonomous operation enabled. 			

$	13-Dec-2018	20:57:47.613	Anchor	Optode Message																												4330,1532,266.375,22.339,29.150,29.080,36.133,7.053,531.6,464.8,115.6  								

$	13-Dec-2018	20:57:47.613	Anchor	Optode Message																												#  								

$	13-Dec-2018	20:57:53.407	Anchor	FLBB Message																											/99/99,99:99:99,695,2315,700,4130,537  									

$	13-Dec-2018	20:58:10.504	Anchor	FLBB post: /99/99,99:99:99,695,2315,700,4130,537  

$	13-Dec-2018	20:57:51.065	Anchor	SBE41 Message						   25.79, 21.9981, 35.4237  	25.790001	25.570898	-0.155588	-0.233334	-0.098333	-0.197473	3.000000																							

$	13-Dec-2018	20:58:10.608	Anchor	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:58:10.959	Anchor	PTH Message														784.690918	23.816667	51.750702	24.654226																			

$	13-Dec-2018	20:58:11.163	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.790001	143.061623	31.725000	132.500000																																

$	13-Dec-2018	20:58:11.274	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:18.4399444

$	13-Dec-2018	20:58:11.482	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.790001	143.054195	31.725000	132.500000																																

$	13-Dec-2018	20:58:12.483	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.790001	143.044874	31.725000	132.500000																																

$	13-Dec-2018	20:58:12.951	Anchor	SBE41 Message						   25.86  	25.860001	25.531771	-0.114388	-0.023333	-0.128333	-0.185972	3.000000																							

$	13-Dec-2018	20:58:13.511	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.860001	143.047020	31.725000	132.500000																																

$	13-Dec-2018	20:58:14.483	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.860001	143.051691	31.725000	132.500000																																

$	13-Dec-2018	20:58:15.484	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.860001	143.041536	31.725000	132.500000																																

$	13-Dec-2018	20:58:15.951	Anchor	SBE41 Message						   24.91  	24.910000	25.449347	-0.069836	0.316667	0.146667	-0.175454	3.000000																							

$	13-Dec-2018	20:58:16.510	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.910000	143.053778	31.725000	132.500000																																

$	13-Dec-2018	20:58:17.484	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.910000	143.041909	31.725000	132.500000																																

$	13-Dec-2018	20:58:18.485	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.910000	143.054120	31.725000	132.500000																																

$	13-Dec-2018	20:58:18.951	Anchor	SBE41 Message						   24.89  	24.889999	25.384019	-0.029393	0.006667	0.161667	-0.165718	3.000000																							

$	13-Dec-2018	20:58:19.511	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.050119	31.725000	132.500000																																

$	13-Dec-2018	20:58:20.485	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.051311	31.725000	132.500000																																

$	13-Dec-2018	20:58:21.486	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.051520	31.725000	132.500000																																

$	13-Dec-2018	20:58:21.952	Anchor	SBE41 Message						   24.90  	24.900000	25.408990	0.000361	-0.003333	0.001667	-0.156720	3.000000																							

$	13-Dec-2018	20:58:22.513	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.044904	31.725000	132.500000																																

$	13-Dec-2018	20:58:23.485	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.054694	31.725000	132.500000																																

$	13-Dec-2018	20:58:24.486	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.056780	31.725000	132.500000																																

$	13-Dec-2018	20:58:24.952	Anchor	SBE41 Message						   25.88  	25.879999	25.468316	0.014158	-0.326667	-0.165000	-0.148357	3.000000																							

$	13-Dec-2018	20:58:25.513	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.049598	31.725000	132.500000																																

$	13-Dec-2018	20:58:26.486	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.054754	31.725000	132.500000																																

$	13-Dec-2018	20:58:27.487	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.055424	31.725000	132.500000																																

$	13-Dec-2018	20:58:27.951	Anchor	SBE41 Message						   25.87  	25.870001	25.412341	0.012697	0.003333	-0.161667	-0.140376	3.000000																							

$	13-Dec-2018	20:58:28.613	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.870001	143.060669	31.725000	132.500000																																

$	13-Dec-2018	20:58:29.487	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.870001	143.048257	31.725000	132.500000																																

$	13-Dec-2018	20:58:30.488	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.870001	143.045232	31.725000	132.500000																																

$	13-Dec-2018	20:58:30.952	Anchor	SBE41 Message						   25.15  	25.150000	25.239271	0.006008	0.240000	0.121667	-0.132584	3.000000																							

$	13-Dec-2018	20:58:31.612	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.150000	143.064097	31.725000	132.500000																																

$	13-Dec-2018	20:58:32.488	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.150000	143.060528	31.725000	132.500000																																

$	13-Dec-2018	20:58:33.489	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.150000	143.038131	31.725000	132.500000																																

$	13-Dec-2018	20:58:33.950	Anchor	SBE41 Message						   24.87  	24.870001	25.143058	0.005977	0.093333	0.166667	-0.125043	3.000000																							

$	13-Dec-2018	20:58:34.517	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.043309	31.725000	132.500000																																

$	13-Dec-2018	20:58:35.489	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.069535	31.725000	132.500000																																

$	13-Dec-2018	20:58:36.490	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.060416	31.725000	132.500000																																

$	13-Dec-2018	20:58:36.951	Anchor	SBE41 Message						   24.89  	24.889999	25.250152	0.014253	-0.006666	0.043333	-0.117929	3.000000																							

$	13-Dec-2018	20:58:37.516	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.045217	31.725000	132.500000																																

$	13-Dec-2018	20:58:38.489	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.057466	31.725000	132.500000																																

$	13-Dec-2018	20:58:39.490	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.050537	31.725000	132.500000																																

$	13-Dec-2018	20:58:39.951	Anchor	SBE41 Message						   25.88  	25.879999	25.430952	0.020695	-0.330000	-0.168333	-0.111255	3.000000																							

$	13-Dec-2018	20:58:40.616	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.039539	31.725000	132.500000																																

$	13-Dec-2018	20:58:41.490	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.053599	31.725000	132.500000																																

$	13-Dec-2018	20:58:42.491	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.070206	31.725000	132.500000																																

$	13-Dec-2018	20:58:42.712	Anchor	ERROR: Missed PH message 1

$	13-Dec-2018	20:58:42.716	Anchor	ERROR: Missed NO3 message 1

$	13-Dec-2018	20:58:43.297	Anchor	CTD post: 25.88	NaN	NaN

$	13-Dec-2018	20:58:42.952	Anchor	SBE41 Message						   25.88  	25.879999	25.459303	0.014773	0.000000	-0.165000	-0.104828	3.000000																							

$	13-Dec-2018	20:58:43.719	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.049464	31.725000	132.500000																																

$	13-Dec-2018	20:58:43.917	Anchor	Sending CTD PTS

$	13-Dec-2018	20:58:44.019	Anchor	Sci Logger sample CTD pts

$	13-Dec-2018	20:58:44.027	Anchor	Sending Optode Do Sample

$	13-Dec-2018	20:58:44.129	Anchor	Sending Optode Wakeup

$	13-Dec-2018	20:58:44.532	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.053360	31.725000	132.500000																																

$	13-Dec-2018	20:58:44.731	Anchor	Sci Logger sample Optode

$	13-Dec-2018	20:58:44.747	Anchor	Sci Logger sample pH and NO3

$	13-Dec-2018	20:58:44.849	Anchor	Sending FLBB run command

$	13-Dec-2018	20:58:44.951	Anchor	Sci Logger sample FLBB

$	13-Dec-2018	20:58:45.056	Anchor	Sending radiometer pollSample

$	13-Dec-2018	20:58:45.158	Anchor	Sci Logger sample Radiometer

$	13-Dec-2018	20:58:45.361	Anchor	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:58:45.681	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.057443	31.725000	132.500000																																

$	13-Dec-2018	20:58:46.362	Anchor	Radiometer Message																																	SATFI40287,-0.0051,-0.0013,-0.0072,-0.2163 			

$	13-Dec-2018	20:58:46.476	Anchor	Radiometer post: SATFI40287,-0.0051,-0.0013,-0.0072,-0.2163 

$	13-Dec-2018	20:58:45.821	Anchor	Optode Message																												4330,1532,266.152,22.348,29.155,29.086,36.138,7.052,531.5,464.6,115.3  								

$	13-Dec-2018	20:58:46.694	Anchor	Optode post: 4330,1532,266.152,22.348,29.155,29.086,36.138,7.052,531.5,464.6,115.3  

$	13-Dec-2018	20:58:45.825	Anchor	Optode Message																												#  								

$	13-Dec-2018	20:58:46.811	Anchor	FLBB Message																											/99/99,99:99:99,695,2314,700,4130,535  									

$	13-Dec-2018	20:58:47.024	Anchor	FLBB post: /99/99,99:99:99,695,2314,700,4130,535  

$	13-Dec-2018	20:58:47.231	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.042229	31.725000	132.500000																																

$	13-Dec-2018	20:58:47.564	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.029384	31.725000	132.500000																																

$	13-Dec-2018	20:58:47.493	Anchor	SBE41 Message						   24.87  	24.870001	25.309942	-0.001766	0.336666	0.168333	-0.098263	3.000000																							

$	13-Dec-2018	20:58:48.590	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.060632	31.725000	132.500000																																

$	13-Dec-2018	20:58:49.564	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.048994	31.725000	132.500000																																

$	13-Dec-2018	20:58:50.564	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.048227	31.725000	132.500000																																

$	13-Dec-2018	20:58:50.452	Anchor	SBE41 Message						   24.85  	24.850000	25.191626	-0.014449	0.006667	0.171666	-0.091849	3.000000																							

$	13-Dec-2018	20:58:51.591	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.036708	31.725000	132.500000																																

$	13-Dec-2018	20:58:52.565	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.059142	31.725000	132.500000																																

$	13-Dec-2018	20:58:53.565	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.054567	31.725000	132.500000																																

$	13-Dec-2018	20:58:53.451	Anchor	SBE41 Message						   25.75  	25.750000	25.261917	-0.011235	-0.300000	-0.146667	-0.085728	3.000000																							

$	13-Dec-2018	20:58:54.691	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.750000	143.062875	31.725000	132.500000																																

$	13-Dec-2018	20:58:55.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.750000	143.039547	31.725000	132.500000																																

$	13-Dec-2018	20:58:56.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.750000	143.028714	31.725000	132.500000																																

$	13-Dec-2018	20:58:56.451	Anchor	SBE41 Message						   25.88  	25.879999	25.407441	0.002382	-0.043333	-0.171666	-0.079925	3.000000																							

$	13-Dec-2018	20:58:57.593	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.057302	31.725000	132.500000																																

$	13-Dec-2018	20:58:58.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.048897	31.725000	132.500000																																

$	13-Dec-2018	20:58:59.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.046364	31.725000	132.500000																																

$	13-Dec-2018	20:58:59.451	Anchor	SBE41 Message						   25.88  	25.879999	25.416562	0.009817	0.000000	-0.021667	-0.074287	3.000000																							

$	13-Dec-2018	20:59:00.693	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.053994	31.725000	132.500000																																

$	13-Dec-2018	20:59:01.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.070623	31.725000	132.500000																																

$	13-Dec-2018	20:59:02.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.879999	143.056847	31.725000	132.500000																																

$	13-Dec-2018	20:59:02.452	Anchor	SBE41 Message						   24.92  	24.920000	25.313597	0.004441	0.320000	0.160000	-0.068716	3.000000																							

$	13-Dec-2018	20:59:03.595	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.920000	143.045753	31.725000	132.500000																																

$	13-Dec-2018	20:59:04.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.920000	143.065125	31.725000	132.500000																																

$	13-Dec-2018	20:59:05.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.920000	143.050797	31.725000	132.500000																																

$	13-Dec-2018	20:59:05.452	Anchor	SBE41 Message						   24.89  	24.889999	25.317966	-0.004789	0.010000	0.165000	-0.063310	3.000000																							

$	13-Dec-2018	20:59:06.694	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.059030	31.725000	132.500000																																

$	13-Dec-2018	20:59:07.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.052943	31.725000	132.500000																																

$	13-Dec-2018	20:59:08.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.060610	31.725000	132.500000																																

$	13-Dec-2018	20:59:08.452	Anchor	SBE41 Message						   25.14  	25.139999	25.481042	-0.008425	-0.083333	-0.036667	-0.058200	3.000000																							

$	13-Dec-2018	20:59:09.594	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.139999	143.069528	31.725000	132.500000																																

$	13-Dec-2018	20:59:10.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.139999	143.057369	31.725000	132.500000																																

$	13-Dec-2018	20:59:11.568	Anchor	PTH Message														784.548584	23.783333	51.750702	24.643501																			

$	13-Dec-2018	20:59:11.769	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.139999	143.054537	31.725000	132.000000																																

$	13-Dec-2018	20:59:11.452	Anchor	SBE41 Message						   25.82  	25.820000	25.597808	-0.007970	-0.226667	-0.155000	-0.053327	3.000000																							

$	13-Dec-2018	20:59:12.595	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058561	31.725000	132.000000																																

$	13-Dec-2018	20:59:13.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.063121	31.725000	132.000000																																

$	13-Dec-2018	20:59:14.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.060215	31.725000	132.000000																																

$	13-Dec-2018	20:59:14.451	Anchor	SBE41 Message						   25.83  	25.830000	25.503919	-0.010081	-0.003333	-0.115000	-0.048504	3.000000																							

$	13-Dec-2018	20:59:15.594	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.045172	31.725000	132.000000																																

$	13-Dec-2018	20:59:16.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.057078	31.725000	132.000000																																

$	13-Dec-2018	20:59:17.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.066145	31.725000	132.000000																																

$	13-Dec-2018	20:59:17.451	Anchor	SBE41 Message						   25.01  	25.010000	25.293981	-0.014369	0.273333	0.135000	-0.043640	3.000000																							

$	13-Dec-2018	20:59:18.594	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.010000	143.067166	31.725000	132.000000																																

$	13-Dec-2018	20:59:19.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.010000	143.053271	31.725000	132.000000																																

$	13-Dec-2018	20:59:20.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.010000	143.052265	31.725000	132.000000																																

$	13-Dec-2018	20:59:20.451	Anchor	SBE41 Message						   24.89  	24.889999	25.197765	-0.011548	0.040000	0.156667	-0.038844	3.000000																							

$	13-Dec-2018	20:59:21.690	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.030442	31.725000	132.000000																																

$	13-Dec-2018	20:59:22.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.050060	31.725000	132.000000																																

$	13-Dec-2018	20:59:23.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.056683	31.725000	132.000000																																

$	13-Dec-2018	20:59:23.451	Anchor	SBE41 Message						   24.89  	24.889999	25.300854	0.003609	0.000000	0.020000	-0.034290	3.000000																							

$	13-Dec-2018	20:59:24.592	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.052429	31.725000	132.000000																																

$	13-Dec-2018	20:59:25.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.064559	31.725000	132.000000																																

$	13-Dec-2018	20:59:26.565	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.046424	31.725000	132.000000																																

$	13-Dec-2018	20:59:26.452	Anchor	SBE41 Message						   25.83  	25.830000	25.445121	0.020273	-0.313334	-0.156667	-0.030019	3.000000																							

$	13-Dec-2018	20:59:27.592	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.056557	31.725000	132.000000																																

$	13-Dec-2018	20:59:28.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.077143	31.725000	132.000000																																

$	13-Dec-2018	20:59:29.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.065803	31.725000	132.000000																																

$	13-Dec-2018	20:59:29.451	Anchor	SBE41 Message						   25.83  	25.830000	25.428913	0.021349	0.000000	-0.156667	-0.025915	3.000000																							

$	13-Dec-2018	20:59:30.691	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.059954	31.725000	132.000000																																

$	13-Dec-2018	20:59:31.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.062949	31.725000	132.000000																																

$	13-Dec-2018	20:59:32.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.031977	31.725000	132.000000																																

$	13-Dec-2018	20:59:32.450	Anchor	SBE41 Message						   25.76  	25.760000	25.262946	0.006217	0.023333	0.011667	-0.021879	3.000000																							

$	13-Dec-2018	20:59:33.593	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.760000	143.058956	31.725000	132.000000																																

$	13-Dec-2018	20:59:34.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.760000	143.046640	31.725000	132.000000																																

$	13-Dec-2018	20:59:35.566	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.760000	143.058315	31.725000	132.000000																																

$	13-Dec-2018	20:59:35.451	Anchor	SBE41 Message						   24.88  	24.879999	25.156380	-0.006668	0.293334	0.158333	-0.017984	3.000000																							

$	13-Dec-2018	20:59:36.693	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.045306	31.725000	132.000000																																

$	13-Dec-2018	20:59:37.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.045299	31.725000	132.000000																																

$	13-Dec-2018	20:59:38.567	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.051371	31.725000	132.000000																																

$	13-Dec-2018	20:59:38.452	Anchor	SBE41 Message						   24.88  	24.879999	25.256079	-0.002991	0.000000	0.146667	-0.014410	3.000000																							

$	13-Dec-2018	20:59:39.595	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.059611	31.725000	132.000000																																

$	13-Dec-2018	20:59:40.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.082477	31.725000	132.000000																																

$	13-Dec-2018	20:59:41.568	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.035337	31.725000	132.000000																																

$	13-Dec-2018	20:59:41.451	Anchor	SBE41 Message						   25.72  	25.719999	25.469925	0.009607	-0.280000	-0.140000	-0.011260	3.000000																							

$	13-Dec-2018	20:59:42.596	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.080056	31.725000	132.000000																																

$	13-Dec-2018	20:59:42.718	Anchor	ERROR: Missed PH message 2

$	13-Dec-2018	20:59:42.819	Anchor	ERROR: Missed NO3 message 2

$	13-Dec-2018	20:59:42.929	Anchor	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	20:59:43.686	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.056564	31.725000	132.000000																																

$	13-Dec-2018	20:59:43.924	Anchor	Sending CTD PTS

$	13-Dec-2018	20:59:43.928	Anchor	Sci Logger sample CTD pts

$	13-Dec-2018	20:59:44.034	Anchor	Sending Optode Do Sample

$	13-Dec-2018	20:59:44.136	Anchor	Sending Optode Wakeup

$	13-Dec-2018	20:59:44.030	Anchor	Unparsed SBE41 Message						S>pts  																														

$	13-Dec-2018	20:59:44.589	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.067338	31.725000	132.000000																																

$	13-Dec-2018	20:59:44.737	Anchor	Sci Logger sample Optode

$	13-Dec-2018	20:59:44.754	Anchor	Sci Logger sample pH and NO3

$	13-Dec-2018	20:59:44.953	Anchor	Sending FLBB run command

$	13-Dec-2018	20:59:44.957	Anchor	Sci Logger sample FLBB

$	13-Dec-2018	20:59:45.062	Anchor	Sending radiometer pollSample

$	13-Dec-2018	20:59:45.263	Anchor	Sci Logger sample Radiometer

$	13-Dec-2018	20:59:45.571	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.057033	31.725000	132.000000																																

$	13-Dec-2018	20:59:46.369	Anchor	Radiometer Message																																	SATFI40287,-0.0049,-0.0014,-0.0072,-0.2356 			

$	13-Dec-2018	20:59:46.483	Anchor	Radiometer post: SATFI40287,-0.0049,-0.0014,-0.0072,-0.2356 

$	13-Dec-2018	20:59:45.828	Anchor	Optode Message																												4330,1532,266.079,22.363,29.152,29.083,36.136,7.053,531.4,464.3,114.8  								

$	13-Dec-2018	20:59:46.701	Anchor	Optode post: 4330,1532,266.079,22.363,29.152,29.083,36.136,7.053,531.4,464.3,114.8  

$	13-Dec-2018	20:59:45.831	Anchor	Optode Message																												#  								

$	13-Dec-2018	20:59:46.818	Anchor	FLBB Message																											/99/99,99:99:99,695,2311,700,4130,535  									

$	13-Dec-2018	20:59:47.032	Anchor	FLBB post: /99/99,99:99:99,695,2311,700,4130,535  

$	13-Dec-2018	20:59:47.336	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.045053	31.725000	132.000000																																

$	13-Dec-2018	20:59:47.448	Anchor	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0787893

$	13-Dec-2018	20:59:47.752	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.055230	31.725000	132.000000																																

$	13-Dec-2018	20:59:48.752	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.065684	31.725000	132.000000																																

$	13-Dec-2018	20:59:49.752	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.050797	31.725000	132.000000																																

$	13-Dec-2018	20:59:50.752	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.719999	143.059909	31.725000	132.000000																																

$	13-Dec-2018	20:59:51.564	Anchor	CTD post: 24.90	22.061	35.21

$	13-Dec-2018	20:59:51.230	Anchor	SBE41 Message						   24.90, 22.0606, 35.2070  	24.900000	25.573810	0.011413	0.273333	-0.003333	-0.008404	3.000000																							

$	13-Dec-2018	20:59:51.889	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.058918	31.725000	132.000000																																

$	13-Dec-2018	20:59:52.753	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.070132	31.725000	132.000000																																

$	13-Dec-2018	20:59:53.753	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.067084	31.725000	132.000000																																

$	13-Dec-2018	20:59:54.451	Anchor	SBE41 Message						   24.90  	24.900000	25.468714	-0.004537	0.000000	0.136667	-0.005815	3.000000																							

$	13-Dec-2018	20:59:54.779	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.059455	31.725000	132.000000																																

$	13-Dec-2018	20:59:55.753	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.062562	31.725000	132.000000																																

$	13-Dec-2018	20:59:56.753	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.053710	31.725000	132.000000																																

$	13-Dec-2018	20:59:57.451	Anchor	SBE41 Message						   25.65  	25.650000	25.285015	-0.022784	-0.250000	-0.125000	-0.003473	3.000000																							

$	13-Dec-2018	20:59:57.781	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.650000	143.055826	31.725000	132.000000																																

$	13-Dec-2018	20:59:58.754	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.650000	143.044151	31.725000	132.000000																																

$	13-Dec-2018	20:59:59.754	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.650000	143.064350	31.725000	132.000000																																

$	13-Dec-2018	21:00:00.450	Anchor	SBE41 Message						   25.83  	25.830000	25.188669	-0.023177	-0.060000	-0.155000	-0.001509	3.000000																							

$	13-Dec-2018	21:00:00.783	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.061340	31.725000	132.000000																																

$	13-Dec-2018	21:00:01.755	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.070854	31.725000	132.000000																																

$	13-Dec-2018	21:00:02.755	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.065698	31.725000	132.000000																																

$	13-Dec-2018	21:00:03.451	Anchor	SBE41 Message						   25.83  	25.830000	25.175112	-0.003376	0.000000	-0.030000	-0.000047	3.000000																							

$	13-Dec-2018	21:00:03.782	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.052854	31.725000	132.000000																																

$	13-Dec-2018	21:00:04.756	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.052176	31.725000	132.000000																																

$	13-Dec-2018	21:00:05.756	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.056273	31.725000	132.000000																																

$	13-Dec-2018	21:00:06.451	Anchor	SBE41 Message						   24.90  	24.900000	25.185497	0.021185	0.310000	0.155000	0.000872	3.000000																							

$	13-Dec-2018	21:00:06.882	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.043026	31.725000	132.000000																																

$	13-Dec-2018	21:00:07.757	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.067993	31.725000	132.000000																																

$	13-Dec-2018	21:00:08.757	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.900000	143.065266	31.725000	132.000000																																

$	13-Dec-2018	21:00:09.452	Anchor	SBE41 Message						   24.88  	24.879999	25.270008	0.033307	0.006667	0.158333	0.001234	3.000000																							

$	13-Dec-2018	21:00:09.784	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.063962	31.725000	132.000000																																

$	13-Dec-2018	21:00:10.757	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.063568	31.725000	132.000000																																

$	13-Dec-2018	21:00:11.758	Anchor	PTH Message														784.152588	23.675000	51.750702	24.643501																			

$	13-Dec-2018	21:00:11.960	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.053442	31.725000	133.000000																																

$	13-Dec-2018	21:00:12.545	Anchor	SBE41 Message						   24.89  	24.889999	25.443383	0.025101	-0.003333	0.001667	0.001086	3.000000																							

$	13-Dec-2018	21:00:12.881	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.055521	31.725000	133.000000																																

$	13-Dec-2018	21:00:13.757	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.046252	31.725000	133.000000																																

$	13-Dec-2018	21:00:14.758	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	143.067613	31.725000	133.000000																																

$	13-Dec-2018	21:00:15.452	Anchor	SBE41 Message						   25.82  	25.820000	25.552003	0.001394	-0.310000	-0.156667	0.000641	3.000000																							

$	13-Dec-2018	21:00:15.784	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.061377	31.725000	133.000000																																

$	13-Dec-2018	21:00:16.758	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.062621	31.725000	133.000000																																

$	13-Dec-2018	21:00:17.759	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058129	31.725000	133.000000																																

$	13-Dec-2018	21:00:18.451	Anchor	SBE41 Message						   25.81  	25.809999	25.457550	-0.022639	0.003333	-0.153333	0.000250	3.000000																							

$	13-Dec-2018	21:00:18.785	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	143.048733	31.725000	133.000000																																

$	13-Dec-2018	21:00:19.759	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	143.049970	31.725000	133.000000																																

$	13-Dec-2018	21:00:20.759	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	143.084787	31.725000	133.000000																																

$	13-Dec-2018	21:00:21.450	Anchor	SBE41 Message						   25.42  	25.420000	25.241622	-0.031672	0.130000	0.066667	0.000186	3.000000																							

$	13-Dec-2018	21:00:21.786	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.420000	143.061832	31.725000	133.000000																																

$	13-Dec-2018	21:00:22.760	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.420000	143.064052	31.725000	133.000000																																

$	13-Dec-2018	21:00:23.760	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.420000	143.057957	31.725000	133.000000																																

$	13-Dec-2018	21:00:24.450	Anchor	SBE41 Message						   24.88  	24.879999	25.127706	-0.020470	0.180000	0.155000	0.000327	3.000000																							

$	13-Dec-2018	21:00:24.787	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.059686	31.725000	133.000000																																

$	13-Dec-2018	21:00:25.761	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.064082	31.725000	133.000000																																

$	13-Dec-2018	21:00:26.761	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.055931	31.725000	133.000000																																

$	13-Dec-2018	21:00:27.451	Anchor	SBE41 Message						   24.87  	24.870001	25.230144	0.003671	0.003333	0.091667	0.000408	3.000000																							

$	13-Dec-2018	21:00:27.788	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.058039	31.725000	133.000000																																

$	13-Dec-2018	21:00:28.761	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.058896	31.725000	133.000000																																

$	13-Dec-2018	21:00:29.762	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.061042	31.725000	133.000000																																

$	13-Dec-2018	21:00:30.452	Anchor	SBE41 Message						   25.84  	25.840000	25.424086	0.023814	-0.323333	-0.160000	0.000236	3.000000																							

$	13-Dec-2018	21:00:30.789	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.052675	31.725000	133.000000																																

$	13-Dec-2018	21:00:31.761	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.058486	31.725000	133.000000																																

$	13-Dec-2018	21:00:32.762	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.073298	31.725000	133.000000																																

$	13-Dec-2018	21:00:33.452	Anchor	SBE41 Message						   25.82  	25.820000	25.488438	0.023461	0.006667	-0.158333	-0.000072	3.000000																							

$	13-Dec-2018	21:00:33.788	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.062845	31.725000	133.000000																																

$	13-Dec-2018	21:00:34.762	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.059507	31.725000	133.000000																																

$	13-Dec-2018	21:00:35.763	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.060371	31.725000	133.000000																																

$	13-Dec-2018	21:00:36.452	Anchor	SBE41 Message						   25.81  	25.809999	25.367847	0.003186	0.003333	0.005000	-0.000182	3.000000																							

$	13-Dec-2018	21:00:36.888	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	143.058635	31.725000	133.000000																																

$	13-Dec-2018	21:00:37.763	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	143.069789	31.725000	133.000000																																

$	13-Dec-2018	21:00:38.763	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	143.063538	31.725000	133.000000																																

$	13-Dec-2018	21:00:39.451	Anchor	SBE41 Message						   24.84  	24.840000	25.239910	-0.016577	0.323333	0.163333	0.000044	3.000000																							

$	13-Dec-2018	21:00:39.790	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.840000	143.073767	31.725000	133.000000																																

$	13-Dec-2018	21:00:40.764	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.840000	143.047534	31.725000	133.000000																																

$	13-Dec-2018	21:00:41.764	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.840000	143.072411	31.725000	133.000000																																

$	13-Dec-2018	21:00:42.452	Anchor	SBE41 Message						   24.86  	24.860001	25.291730	-0.017194	-0.006667	0.158333	0.000325	3.000000																							

$	13-Dec-2018	21:00:42.712	Anchor	ERROR: Missed PH message 3

$	13-Dec-2018	21:00:42.717	Anchor	ERROR: Missed NO3 message 3

$	13-Dec-2018	21:00:42.922	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.064283	31.725000	133.000000																																

$	13-Dec-2018	21:00:43.765	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.065944	31.725000	133.000000																																

$	13-Dec-2018	21:00:43.918	Anchor	Sending CTD PTS

$	13-Dec-2018	21:00:43.922	Anchor	Sci Logger sample CTD pts

$	13-Dec-2018	21:00:44.029	Anchor	Sending Optode Do Sample

$	13-Dec-2018	21:00:44.130	Anchor	Sending Optode Wakeup

$	13-Dec-2018	21:00:44.024	Anchor	Unparsed SBE41 Message						S>pts  																														

$	13-Dec-2018	21:00:44.784	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.080004	31.725000	133.000000																																

$	13-Dec-2018	21:00:44.910	Anchor	Sci Logger sample Optode

$	13-Dec-2018	21:00:44.914	Anchor	Sci Logger sample pH and NO3

$	13-Dec-2018	21:00:45.016	Anchor	Sending FLBB run command

$	13-Dec-2018	21:00:45.117	Anchor	Sci Logger sample FLBB

$	13-Dec-2018	21:00:45.222	Anchor	Sending radiometer pollSample

$	13-Dec-2018	21:00:45.421	Anchor	Sci Logger sample Radiometer

$	13-Dec-2018	21:00:45.564	Anchor	Radiometer Message																																	SATFI40287,-0.0045,0.0013,-0.0076,-0.2263 			

$	13-Dec-2018	21:00:45.678	Anchor	Radiometer post: SATFI40287,-0.0045,0.0013,-0.0076,-0.2263 

$	13-Dec-2018	21:00:45.912	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.062741	31.725000	133.000000																																

$	13-Dec-2018	21:00:46.024	Anchor	Optode Message																												4330,1532,265.897,22.386,29.150,29.081,36.137,7.056,531.3,464.0,114.0  								

$	13-Dec-2018	21:00:46.680	Anchor	Optode post: 4330,1532,265.897,22.386,29.150,29.081,36.137,7.056,531.3,464.0,114.0  

$	13-Dec-2018	21:00:46.024	Anchor	Optode Message																												#  								

$	13-Dec-2018	21:00:46.797	Anchor	FLBB Message																											/99/99,99:99:99,695,2313,700,4130,534  									

$	13-Dec-2018	21:00:47.008	Anchor	FLBB post: /99/99,99:99:99,695,2313,700,4130,534  

$	13-Dec-2018	21:00:47.217	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.073194	31.725000	133.000000																																

$	13-Dec-2018	21:00:47.766	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.058918	31.725000	133.000000																																

$	13-Dec-2018	21:00:48.766	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.067271	31.725000	133.000000																																

$	13-Dec-2018	21:00:49.766	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.064700	31.725000	133.000000																																

$	13-Dec-2018	21:00:50.767	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.052593	31.725000	133.000000																																

$	13-Dec-2018	21:00:51.577	Anchor	CTD post: 25.84	22.082	35.21

$	13-Dec-2018	21:00:51.124	Anchor	SBE41 Message						   25.84, 22.0822, 35.2077  	25.840000	25.478948	-0.002754	-0.326667	-0.166667	0.000271	3.000000																							

$	13-Dec-2018	21:00:51.901	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.056795	31.725000	133.000000																																

$	13-Dec-2018	21:00:52.767	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.065222	31.725000	133.000000																																

$	13-Dec-2018	21:00:53.768	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.065199	31.725000	133.000000																																

$	13-Dec-2018	21:00:53.984	Anchor	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	21:00:54.787	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.064342	31.725000	133.000000																																

$	13-Dec-2018	21:00:55.768	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.840000	143.044814	31.725000	133.000000																																

$	13-Dec-2018	21:00:56.452	Anchor	SBE41 Message						   24.86  	24.860001	25.578728	0.006401	0.326667	0.000000	-0.000096	3.000000																							

$	13-Dec-2018	21:00:56.795	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.054813	31.725000	133.000000																																

$	13-Dec-2018	21:00:57.769	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.058658	31.725000	133.000000																																

$	13-Dec-2018	21:00:58.769	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.062130	31.725000	133.000000																																

$	13-Dec-2018	21:00:59.451	Anchor	SBE41 Message						   24.86  	24.860001	25.473270	-0.001101	0.000000	0.163333	-0.000354	3.000000																							

$	13-Dec-2018	21:00:59.796	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.070921	31.725000	133.000000																																

$	13-Dec-2018	21:01:00.770	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.072993	31.725000	133.000000																																

$	13-Dec-2018	21:01:01.770	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	143.069878	31.725000	133.000000																																

$	13-Dec-2018	21:01:02.451	Anchor	SBE41 Message						   25.83  	25.830000	25.290521	-0.014711	-0.323333	-0.161667	-0.000228	3.000000																							

$	13-Dec-2018	21:01:02.797	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.080562	31.725000	133.000000																																

$	13-Dec-2018	21:01:03.771	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.078767	31.725000	133.000000																																

$	13-Dec-2018	21:01:04.771	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.075839	31.725000	133.000000																																

$	13-Dec-2018	21:01:05.452	Anchor	SBE41 Message						   25.83  	25.830000	25.201140	-0.016053	0.000000	-0.161667	0.000121	3.000000																							

$	13-Dec-2018	21:01:05.798	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.070519	31.725000	133.000000																																

$	13-Dec-2018	21:01:06.772	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.066920	31.725000	133.000000																																

$	13-Dec-2018	21:01:07.772	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.068269	31.725000	133.000000																																

$	13-Dec-2018	21:01:08.451	Anchor	SBE41 Message						   25.82  	25.820000	25.193871	-0.000310	0.003333	0.001667	0.000395	3.000000																							

$	13-Dec-2018	21:01:08.799	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.062845	31.725000	133.000000																																

$	13-Dec-2018	21:01:09.772	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.051565	31.725000	133.000000																																

$	13-Dec-2018	21:01:10.773	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.043920	31.725000	133.000000																																

$	13-Dec-2018	21:01:11.451	Anchor	SBE41 Message						   24.85  	24.850000	25.207377	0.020995	0.323333	0.163333	0.000489	3.000000																							

$	13-Dec-2018	21:01:11.799	Anchor	PTH Message														785.179932	23.725000	51.750702	24.622051																			

$	13-Dec-2018	21:01:12.004	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.063597	31.700000	132.500000																																

$	13-Dec-2018	21:01:12.773	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.073000	31.700000	132.500000																																

$	13-Dec-2018	21:01:13.773	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.061906	31.700000	132.500000																																

$	13-Dec-2018	21:01:14.451	Anchor	SBE41 Message						   24.85  	24.850000	25.301327	0.032030	0.000000	0.161667	0.000460	3.000000																							

$	13-Dec-2018	21:01:14.899	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.068135	31.700000	132.500000																																

$	13-Dec-2018	21:01:15.774	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.041335	31.700000	132.500000																																

$	13-Dec-2018	21:01:16.775	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	143.074885	31.700000	132.500000																																

$	13-Dec-2018	21:01:17.451	Anchor	SBE41 Message						   25.77  	25.770000	25.483296	0.023433	-0.306667	-0.153333	0.000343	3.000000																							

$	13-Dec-2018	21:01:17.801	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.770000	143.068090	31.700000	132.500000																																

$	13-Dec-2018	21:01:18.775	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.770000	143.054917	31.700000	132.500000																																

$	13-Dec-2018	21:01:19.775	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.770000	143.046901	31.700000	132.500000																																

$	13-Dec-2018	21:01:20.450	Anchor	SBE41 Message						   25.83  	25.830000	25.581664	-0.000923	-0.020000	-0.163333	0.000128	3.000000																							

$	13-Dec-2018	21:01:20.802	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.055491	31.700000	132.500000																																

$	13-Dec-2018	21:01:21.776	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.065900	31.700000	132.500000																																

$	13-Dec-2018	21:01:22.776	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.050164	31.700000	132.500000																																

$	13-Dec-2018	21:01:23.450	Anchor	SBE41 Message						   25.83  	25.830000	25.478764	-0.024739	0.000000	-0.010000	-0.000138	3.000000																							

$	13-Dec-2018	21:01:23.803	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.055506	31.700000	132.500000																																

$	13-Dec-2018	21:01:24.777	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.051796	31.700000	132.500000																																

$	13-Dec-2018	21:01:25.777	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.830000	143.063389	31.700000	132.500000																																

$	13-Dec-2018	21:01:26.451	Anchor	SBE41 Message						   24.87  	24.870001	25.312387	-0.032105	0.320000	0.160000	-0.000359	3.000000																							

$	13-Dec-2018	21:01:26.804	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.075503	31.700000	132.500000																																

$	13-Dec-2018	21:01:27.777	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.053472	31.700000	132.500000																																

$	13-Dec-2018	21:01:28.778	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.040672	31.700000	132.500000																																

$	13-Dec-2018	21:01:29.451	Anchor	SBE41 Message						   24.87  	24.870001	25.306216	-0.020535	0.000000	0.160000	-0.000487	3.000000																							

$	13-Dec-2018	21:01:29.804	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.059291	31.700000	132.500000																																

$	13-Dec-2018	21:01:30.778	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.065602	31.700000	132.500000																																

$	13-Dec-2018	21:01:31.778	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	143.061936	31.700000	132.500000																																

$	13-Dec-2018	21:01:32.451	Anchor	SBE41 Message						   24.88  	24.879999	25.465642	-0.001060	-0.003333	-0.001666	-0.000562	3.000000																							

$	13-Dec-2018	21:01:32.805	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.058218	31.700000	132.500000																																

$	13-Dec-2018	21:01:33.779	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.077582	31.700000	132.500000																																

$	13-Dec-2018	21:01:34.779	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	143.073849	31.700000	132.500000																																

$	13-Dec-2018	21:01:35.452	Anchor	SBE41 Message						   25.82  	25.820000	25.569708	0.010921	-0.313334	-0.158333	-0.000627	3.000000																							

$	13-Dec-2018	21:01:35.806	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.055812	31.700000	132.500000																																

$	13-Dec-2018	21:01:36.780	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.070772	31.700000	132.500000																																

$	13-Dec-2018	21:01:37.780	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.073931	31.700000	132.500000																																

$	13-Dec-2018	21:01:38.452	Anchor	SBE41 Message						   25.82  	25.820000	25.460459	0.006988	0.000000	-0.156667	-0.000675	3.000000																							

$	13-Dec-2018	21:01:38.807	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.055163	31.700000	132.500000																																

$	13-Dec-2018	21:01:39.781	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.046714	31.700000	132.500000																																

$	13-Dec-2018	21:01:40.781	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058181	31.700000	132.500000																																

$	13-Dec-2018	21:01:41.451	Anchor	SBE41 Message						   25.22  	25.219999	25.232391	-0.005267	0.200000	0.100000	-0.000645	3.000000																							

$	13-Dec-2018	21:01:41.808	Anchor	Normal State Exit

$	13-Dec-2018	21:01:41.922	Anchor	ERROR: Missed PH message 4

$	13-Dec-2018	21:01:42.024	Anchor	ERROR: Missed NO3 message 4

$	13-Dec-2018	21:01:41.812	Anchor	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.048882	31.700000	132.500000																																

$	13-Dec-2018	21:01:42.579	Start CP Mode	State Entry

$	13-Dec-2018	21:01:42.583	Start CP Mode	Stopping SBE41 Timer

$	13-Dec-2018	21:01:42.991	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.056937	31.700000	132.500000																																

$	13-Dec-2018	21:01:43.128	Start CP Mode	Sending CTD PTS

$	13-Dec-2018	21:01:43.132	Start CP Mode	Sci Logger sample CTD pts

$	13-Dec-2018	21:01:43.239	Start CP Mode	Sending Optode Do Sample

$	13-Dec-2018	21:01:43.342	Start CP Mode	Sending Optode Wakeup

$	13-Dec-2018	21:01:43.235	Start CP Mode	Unparsed SBE41 Message						S>pts  																														

$	13-Dec-2018	21:01:43.802	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.062875	31.700000	132.500000																																

$	13-Dec-2018	21:01:43.944	Start CP Mode	Sci Logger sample Optode

$	13-Dec-2018	21:01:43.963	Start CP Mode	Sci Logger sample pH and NO3

$	13-Dec-2018	21:01:44.162	Start CP Mode	Sending FLBB run command

$	13-Dec-2018	21:01:44.166	Start CP Mode	Sci Logger sample FLBB

$	13-Dec-2018	21:01:44.271	Start CP Mode	Sending radiometer pollSample

$	13-Dec-2018	21:01:44.373	Start CP Mode	Sci Logger sample Radiometer

$	13-Dec-2018	21:01:44.579	Start CP Mode	SBE41 Timer Stopped, Sending SBE41 CR/LF

$	13-Dec-2018	21:01:44.883	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.068664	31.700000	132.500000																																

$	13-Dec-2018	21:01:45.582	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:45.586	Start CP Mode	Radiometer Message																																	SATFI40287,-0.0040,0.0002,-0.0084,-0.2336 			

$	13-Dec-2018	21:01:45.798	Start CP Mode	Radiometer post: SATFI40287,-0.0040,0.0002,-0.0084,-0.2336 

$	13-Dec-2018	21:01:45.035	Start CP Mode	Optode Message																												4330,1532,265.866,22.406,29.144,29.074,36.128,7.054,531.1,463.9,113.4  								

$	13-Dec-2018	21:01:46.016	Start CP Mode	Optode post: 4330,1532,265.866,22.406,29.144,29.074,36.128,7.054,531.1,463.9,113.4  

$	13-Dec-2018	21:01:45.038	Start CP Mode	Optode Message																												#  								

$	13-Dec-2018	21:01:46.133	Start CP Mode	FLBB Message																											/99/99,99:99:99,695,2313,700,4130,534  									

$	13-Dec-2018	21:01:46.341	Start CP Mode	FLBB post: /99/99,99:99:99,695,2313,700,4130,534  

$	13-Dec-2018	21:01:46.656	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.066026	31.700000	132.500000																																

$	13-Dec-2018	21:01:46.767	Start CP Mode	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1881282

$	13-Dec-2018	21:01:46.773	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:47.294	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.065833	31.700000	132.500000																																

$	13-Dec-2018	21:01:47.773	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:48.077	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.060088	31.700000	132.500000																																

$	13-Dec-2018	21:01:48.773	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:49.079	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.058665	31.700000	132.500000																																

$	13-Dec-2018	21:01:49.773	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:50.076	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.219999	143.054366	31.700000	132.500000																																

$	13-Dec-2018	21:01:50.773	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:50.888	Start CP Mode	CTD post: 25.82	22.099	35.20

$	13-Dec-2018	21:01:50.333	Start CP Mode	SBE41 Message						   25.82, 22.0986, 35.2026  	25.820000	25.115831	-0.007627	-0.200000	0.000000	-0.000461	3.000000																							

$	13-Dec-2018	21:01:51.310	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.080212	31.700000	132.500000																																

$	13-Dec-2018	21:01:51.774	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:52.078	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.064164	31.700000	132.500000																																

$	13-Dec-2018	21:01:52.773	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:52.981	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.074431	31.700000	132.500000																																

$	13-Dec-2018	21:01:53.774	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:53.980	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.052503	31.700000	132.500000																																

$	13-Dec-2018	21:01:54.775	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:54.982	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.066622	31.700000	132.500000																																

$	13-Dec-2018	21:01:55.775	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:55.982	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.078707	31.700000	132.500000																																

$	13-Dec-2018	21:01:56.776	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:56.984	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.067457	31.700000	132.500000																																

$	13-Dec-2018	21:01:57.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:57.983	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.071122	31.700000	132.500000																																

$	13-Dec-2018	21:01:58.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:01:59.081	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.057510	31.700000	132.500000																																

$	13-Dec-2018	21:01:59.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:00.081	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.050879	31.700000	132.500000																																

$	13-Dec-2018	21:02:00.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:00.983	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.045589	31.700000	132.500000																																

$	13-Dec-2018	21:02:01.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:01.984	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.063568	31.700000	132.500000																																

$	13-Dec-2018	21:02:02.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:03.081	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.092766	31.700000	132.500000																																

$	13-Dec-2018	21:02:03.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:04.083	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.083923	31.700000	132.500000																																

$	13-Dec-2018	21:02:04.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:05.081	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.077001	31.700000	132.500000																																

$	13-Dec-2018	21:02:05.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:05.984	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.073864	31.700000	132.500000																																

$	13-Dec-2018	21:02:06.777	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:07.081	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.065542	31.700000	132.500000																																

$	13-Dec-2018	21:02:07.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:07.984	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.073693	31.700000	132.500000																																

$	13-Dec-2018	21:02:08.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:09.076	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.059559	31.700000	132.500000																																

$	13-Dec-2018	21:02:09.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:10.082	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.066972	31.700000	132.500000																																

$	13-Dec-2018	21:02:10.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:11.083	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.066533	31.700000	132.500000																																

$	13-Dec-2018	21:02:11.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:12.082	Start CP Mode	PTH Message														784.045410	23.725000	51.773590	24.622051																			

$	13-Dec-2018	21:02:12.284	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.055715	31.700000	131.500000																																

$	13-Dec-2018	21:02:12.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:13.082	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.067971	31.700000	131.500000																																

$	13-Dec-2018	21:02:13.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:14.083	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.049307	31.700000	131.500000																																

$	13-Dec-2018	21:02:14.778	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:14.985	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058762	31.700000	131.500000																																

$	13-Dec-2018	21:02:15.779	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:15.985	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.072769	31.700000	131.500000																																

$	13-Dec-2018	21:02:16.779	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:16.987	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.067591	31.700000	131.500000																																

$	13-Dec-2018	21:02:17.780	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:18.083	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.084884	31.700000	131.500000																																

$	13-Dec-2018	21:02:18.779	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:19.083	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.065758	31.700000	131.500000																																

$	13-Dec-2018	21:02:19.780	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:19.987	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.059954	31.700000	131.500000																																

$	13-Dec-2018	21:02:20.780	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:20.988	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.054403	31.700000	131.500000																																

$	13-Dec-2018	21:02:21.781	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:21.987	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.049352	31.700000	131.500000																																

$	13-Dec-2018	21:02:22.782	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:22.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.047206	31.700000	131.500000																																

$	13-Dec-2018	21:02:23.782	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:23.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058054	31.700000	131.500000																																

$	13-Dec-2018	21:02:24.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:25.086	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058933	31.700000	131.500000																																

$	13-Dec-2018	21:02:25.782	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:26.086	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.083170	31.700000	131.500000																																

$	13-Dec-2018	21:02:26.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:27.089	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.065274	31.700000	131.500000																																

$	13-Dec-2018	21:02:27.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:28.087	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.057123	31.700000	131.500000																																

$	13-Dec-2018	21:02:28.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:29.086	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.059574	31.700000	131.500000																																

$	13-Dec-2018	21:02:29.782	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:29.991	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.051818	31.700000	131.500000																																

$	13-Dec-2018	21:02:30.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:30.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.063664	31.700000	131.500000																																

$	13-Dec-2018	21:02:31.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:31.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.054932	31.700000	131.500000																																

$	13-Dec-2018	21:02:32.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:32.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.059582	31.700000	131.500000																																

$	13-Dec-2018	21:02:33.783	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:33.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.079750	31.700000	131.500000																																

$	13-Dec-2018	21:02:34.784	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:35.087	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.068463	31.700000	131.500000																																

$	13-Dec-2018	21:02:35.784	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:35.990	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.096954	31.700000	131.500000																																

$	13-Dec-2018	21:02:36.784	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:36.992	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.064089	31.700000	131.500000																																

$	13-Dec-2018	21:02:37.785	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:37.992	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.083081	31.700000	131.500000																																

$	13-Dec-2018	21:02:38.785	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:38.991	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.052571	31.700000	131.500000																																

$	13-Dec-2018	21:02:39.785	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:39.992	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.063210	31.700000	131.500000																																

$	13-Dec-2018	21:02:40.785	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:41.089	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.066660	31.700000	131.500000																																

$	13-Dec-2018	21:02:41.785	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:41.992	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.054716	31.700000	131.500000																																

$	13-Dec-2018	21:02:42.786	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:42.992	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.074788	31.700000	131.500000																																

$	13-Dec-2018	21:02:43.786	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:43.994	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.061176	31.700000	131.500000																																

$	13-Dec-2018	21:02:44.787	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:44.993	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.095098	31.700000	131.500000																																

$	13-Dec-2018	21:02:45.787	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:45.994	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.071316	31.700000	131.500000																																

$	13-Dec-2018	21:02:46.788	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:46.995	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.055081	31.700000	131.500000																																

$	13-Dec-2018	21:02:47.789	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:48.093	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.073186	31.700000	131.500000																																

$	13-Dec-2018	21:02:48.789	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:49.093	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.067174	31.700000	131.500000																																

$	13-Dec-2018	21:02:49.789	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:49.995	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.085234	31.700000	131.500000																																

$	13-Dec-2018	21:02:50.790	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:50.998	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.051513	31.700000	131.500000																																

$	13-Dec-2018	21:02:51.791	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:51.998	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.051259	31.700000	131.500000																																

$	13-Dec-2018	21:02:52.791	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:52.997	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.056631	31.700000	131.500000																																

$	13-Dec-2018	21:02:53.791	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:53.997	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.041074	31.700000	131.500000																																

$	13-Dec-2018	21:02:54.791	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:54.998	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.061534	31.700000	131.500000																																

$	13-Dec-2018	21:02:55.791	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:55.999	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.076837	31.700000	131.500000																																

$	13-Dec-2018	21:02:56.792	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:56.998	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.080249	31.700000	131.500000																																

$	13-Dec-2018	21:02:57.793	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:58.001	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.067993	31.700000	131.500000																																

$	13-Dec-2018	21:02:58.794	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:02:59.001	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.062934	31.700000	131.500000																																

$	13-Dec-2018	21:02:59.794	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:00.000	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.048443	31.700000	131.500000																																

$	13-Dec-2018	21:03:00.795	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:01.001	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.060841	31.700000	131.500000																																

$	13-Dec-2018	21:03:01.795	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:02.002	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.059537	31.700000	131.500000																																

$	13-Dec-2018	21:03:02.795	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:03.002	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.080324	31.700000	131.500000																																

$	13-Dec-2018	21:03:03.796	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:04.002	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058106	31.700000	131.500000																																

$	13-Dec-2018	21:03:04.796	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:05.102	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.070117	31.700000	131.500000																																

$	13-Dec-2018	21:03:05.797	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:06.101	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.058613	31.700000	131.500000																																

$	13-Dec-2018	21:03:06.796	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:07.004	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.065758	31.700000	131.500000																																

$	13-Dec-2018	21:03:07.797	Start CP Mode	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:03:07.901	Start CP Mode	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	21:03:08.123	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.071651	31.700000	131.500000																																

$	13-Dec-2018	21:03:08.797	Start CP Mode	Got CR/LF response, sending startprofile

$	13-Dec-2018	21:03:09.004	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.068954	31.700000	131.500000																																

$	13-Dec-2018	21:03:09.798	Start CP Mode	Didn't get startprofile response, retrying

$	13-Dec-2018	21:03:09.919	Start CP Mode	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:03:09.918	Start CP Mode	Unparsed SBE41 Message						S>startprofile5  																														

$	13-Dec-2018	21:03:10.340	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.075556	31.700000	131.500000																																

$	13-Dec-2018	21:03:10.798	Start CP Mode	Didn't get startprofile response, retrying

$	13-Dec-2018	21:03:10.902	Start CP Mode	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:03:11.109	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.049933	31.700000	131.500000																																

$	13-Dec-2018	21:03:11.798	Start CP Mode	Didn't get startprofile response, retrying

$	13-Dec-2018	21:03:11.901	Start CP Mode	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:03:12.204	Start CP Mode	PTH Message														784.603027	23.766667	51.804108	24.600601																			

$	13-Dec-2018	21:03:12.408	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.080726	NaN	154.500000																																

$	13-Dec-2018	21:03:12.798	Start CP Mode	Didn't get startprofile response, retrying

$	13-Dec-2018	21:03:12.901	Start CP Mode	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:03:13.107	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.069796	NaN	154.500000																																

$	13-Dec-2018	21:03:13.799	Start CP Mode	Didn't get startprofile response, retrying

$	13-Dec-2018	21:03:13.901	Start CP Mode	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:03:13.695	Start CP Mode	Unparsed SBE41 Message						profile started, pump delay = 5 seconds  																														

$	13-Dec-2018	21:03:14.226	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.069871	NaN	154.500000																																

$	13-Dec-2018	21:03:14.799	Start CP Mode	Got startprofile response

$	13-Dec-2018	21:03:14.803	Start CP Mode	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:03:14.905	Start CP Mode	Starting valve open

$	13-Dec-2018	21:03:15.306	Start CP Mode	Normal State Exit

$	13-Dec-2018	21:03:15.310	Start CP Mode	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.055230	NaN	154.500000																																

$	13-Dec-2018	21:03:15.799	DeAnchor	State Entry

$	13-Dec-2018	21:03:15.905	DeAnchor	Deanchor JV = 200000.0

$	13-Dec-2018	21:03:15.910	DeAnchor	Initializing SBE 41 LPF

$	13-Dec-2018	21:03:16.114	DeAnchor	Starting valve open

$	13-Dec-2018	21:03:16.522	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.063672	NaN	154.500000																																

$	13-Dec-2018	21:03:17.002	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.065177	NaN	154.500000																																

$	13-Dec-2018	21:03:18.001	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.063419	NaN	154.500000																																

$	13-Dec-2018	21:03:19.002	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	143.080205	NaN	154.500000																																

$	13-Dec-2018	21:03:19.439	DeAnchor	Unparsed SBE41 Message						S>   25.75, 22.1205, 35.1873  																														

$	13-Dec-2018	21:03:20.469	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	142.891705	NaN	154.500000																																

$	13-Dec-2018	21:03:20.436	DeAnchor	SBE41 Message						   25.12, 22.1018, 35.1975  	25.120001	25.819989	0.000001	0.699999	0.349999	0.000001	1.000000																							

$	13-Dec-2018	21:03:21.036	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.120001	142.645560	NaN	154.500000																																

$	13-Dec-2018	21:03:21.436	DeAnchor	SBE41 Message						   24.85, 22.1072, 35.2007  	24.850000	25.817920	0.000257	0.270000	0.485000	0.000008	1.000000																							

$	13-Dec-2018	21:03:22.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.850000	142.593808	NaN	154.500000																																

$	13-Dec-2018	21:03:22.436	DeAnchor	SBE41 Message						   24.87, 22.1139, 35.1999  	24.870001	25.797399	0.002794	-0.020000	0.125000	0.000068	1.000000																							

$	13-Dec-2018	21:03:23.035	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	142.377235	NaN	154.500000																																

$	13-Dec-2018	21:03:23.434	DeAnchor	SBE41 Message						   24.87, 22.1177, 35.1951  	24.870001	25.714968	0.012984	0.000000	-0.010000	0.000278	1.000000																							

$	13-Dec-2018	21:03:24.037	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	142.238095	NaN	154.500000																																

$	13-Dec-2018	21:03:24.434	DeAnchor	SBE41 Message						   24.86, 22.1187, 35.1895  	24.860001	25.531383	0.035682	0.010000	0.005000	0.000733	1.000000																							

$	13-Dec-2018	21:03:25.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	142.108373	NaN	154.500000																																

$	13-Dec-2018	21:03:25.432	DeAnchor	SBE41 Message						   24.86, 22.1194, 35.2017  	24.860001	25.277501	0.067081	0.000000	0.005000	0.001428	1.000000																							

$	13-Dec-2018	21:03:26.035	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	141.897693	NaN	154.500000																																

$	13-Dec-2018	21:03:26.431	DeAnchor	SBE41 Message						   24.86, 22.1175, 35.2051  	24.860001	25.050750	0.095137	0.000000	0.000000	0.002232	1.000000																							

$	13-Dec-2018	21:03:27.036	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.860001	141.697116	NaN	154.500000																																

$	13-Dec-2018	21:03:27.430	DeAnchor	SBE41 Message						   24.89, 22.1173, 35.2012  	24.889999	24.920514	0.111268	-0.029999	-0.014999	0.002997	1.000000																							

$	13-Dec-2018	21:03:28.139	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.889999	141.540021	NaN	154.500000																																

$	13-Dec-2018	21:03:28.429	DeAnchor	SBE41 Message						   25.75, 22.1173, 35.2035  	25.750000	24.874226	0.117013	-0.860001	-0.445000	0.003650	1.000000																							

$	13-Dec-2018	21:03:29.035	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.750000	141.370676	NaN	154.500000																																

$	13-Dec-2018	21:03:29.429	DeAnchor	SBE41 Message						   25.80, 22.1172, 35.2046  	25.799999	24.867273	0.117622	-0.049999	-0.455000	0.004185	1.000000																							

$	13-Dec-2018	21:03:30.035	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.799999	141.269244	NaN	154.500000																																

$	13-Dec-2018	21:03:30.428	DeAnchor	SBE41 Message						   25.81, 22.1182, 35.2018  	25.809999	24.892403	0.111964	-0.010000	-0.030000	0.004606	1.000000																							

$	13-Dec-2018	21:03:31.133	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	141.181923	NaN	154.500000																																

$	13-Dec-2018	21:03:31.427	DeAnchor	SBE41 Message						   25.82, 22.1187, 35.1977  	25.820000	24.991477	0.089497	-0.010000	-0.010000	0.004880	1.000000																							

$	13-Dec-2018	21:03:32.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	140.938625	NaN	154.500000																																

$	13-Dec-2018	21:03:32.425	DeAnchor	SBE41 Message						   25.81, 22.1193, 35.2043  	25.809999	25.196014	0.041482	0.010000	0.000000	0.004961	1.000000																							

$	13-Dec-2018	21:03:33.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	140.749604	NaN	154.500000																																

$	13-Dec-2018	21:03:33.424	DeAnchor	SBE41 Message						   25.81, 22.1198, 35.2039  	25.809999	25.455980	-0.022075	0.000000	0.005000	0.004846	1.000000																							

$	13-Dec-2018	21:03:34.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.809999	140.546575	NaN	154.500000																																

$	13-Dec-2018	21:03:34.423	DeAnchor	SBE41 Message						   25.82, 22.1196, 35.2044  	25.820000	25.666957	-0.076223	-0.010000	-0.005000	0.004604	1.000000																							

$	13-Dec-2018	21:03:35.035	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.820000	140.323564	NaN	154.500000																																

$	13-Dec-2018	21:03:35.423	DeAnchor	SBE41 Message						   25.80, 22.1192, 35.2011  	25.799999	25.774869	-0.105695	0.020000	0.005000	0.004322	1.000000																							

$	13-Dec-2018	21:03:36.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.799999	140.199251	NaN	154.500000																																

$	13-Dec-2018	21:03:36.420	DeAnchor	SBE41 Message						   25.27, 22.1194, 35.2019  	25.270000	25.807557	-0.115479	0.529999	0.275000	0.004049	1.000000																							

$	13-Dec-2018	21:03:37.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.270000	139.979184	NaN	154.500000																																

$	13-Dec-2018	21:03:37.421	DeAnchor	SBE41 Message						   24.87, 22.1197, 35.2057  	24.870001	25.810925	-0.116756	0.400000	0.464999	0.003802	1.000000																							

$	13-Dec-2018	21:03:38.132	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	139.817625	NaN	154.500000																																

$	13-Dec-2018	21:03:38.420	DeAnchor	SBE41 Message						   24.88, 22.1203, 35.2016  	24.879999	25.794184	-0.111561	-0.009998	0.195001	0.003587	1.000000																							

$	13-Dec-2018	21:03:39.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	139.652126	NaN	154.500000																																

$	13-Dec-2018	21:03:39.418	DeAnchor	SBE41 Message						   24.87, 22.1210, 35.2046  	24.870001	25.723853	-0.090588	0.009998	0.000000	0.003427	1.000000																							

$	13-Dec-2018	21:03:40.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	139.443561	NaN	154.500000																																

$	13-Dec-2018	21:03:40.416	DeAnchor	SBE41 Message						   24.87, 22.1204, 35.2026  	24.870001	25.560121	-0.045031	0.000000	0.004999	0.003364	1.000000																							

$	13-Dec-2018	21:03:41.130	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	139.276356	NaN	154.500000																																

$	13-Dec-2018	21:03:41.418	DeAnchor	SBE41 Message						   24.88, 22.1216, 35.2027  	24.879999	25.320311	0.016780	-0.009998	-0.004999	0.003425	1.000000																							

$	13-Dec-2018	21:03:42.035	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	139.132246	NaN	154.500000																																

$	13-Dec-2018	21:03:42.414	DeAnchor	SBE41 Message						   24.88, 22.1210, 35.2024  	24.879999	25.090014	0.071359	0.000000	-0.004999	0.003594	1.000000																							

$	13-Dec-2018	21:03:43.129	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.879999	139.065370	NaN	154.500000																																

$	13-Dec-2018	21:03:43.414	DeAnchor	SBE41 Message						   24.87, 22.1215, 35.2034  	24.870001	24.944926	0.102666	0.009998	0.004999	0.003820	1.000000																							

$	13-Dec-2018	21:03:44.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	138.830207	NaN	154.500000																																

$	13-Dec-2018	21:03:44.412	DeAnchor	SBE41 Message						   24.87, 22.1215, 35.2050  	24.870001	24.887599	0.113818	0.000000	0.004999	0.004060	1.000000																							

$	13-Dec-2018	21:03:45.134	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.870001	138.686232	NaN	154.500000																																

$	13-Dec-2018	21:03:45.413	DeAnchor	SBE41 Message						   24.93, 22.1223, 35.2000  	24.930000	24.875553	0.115732	-0.059999	-0.030000	0.004293	1.000000																							

$	13-Dec-2018	21:03:46.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.930000	138.483740	NaN	154.500000																																

$	13-Dec-2018	21:03:46.411	DeAnchor	SBE41 Message						   25.27, 22.1232, 35.2011  	25.270000	24.875491	0.113658	-0.340000	-0.200000	0.004515	1.000000																							

$	13-Dec-2018	21:03:47.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.270000	138.343774	NaN	154.500000																																

$	13-Dec-2018	21:03:47.410	DeAnchor	SBE41 Message						   25.34, 22.1234, 35.2041  	25.340000	24.877927	0.104636	-0.070000	-0.205000	0.004728	1.000000																							

$	13-Dec-2018	21:03:48.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.340000	138.268650	NaN	154.500000																																

$	13-Dec-2018	21:03:48.409	DeAnchor	SBE41 Message						   25.34, 22.1234, 35.2031  	25.340000	24.892372	0.082580	0.000000	-0.035000	0.004930	1.000000																							

$	13-Dec-2018	21:03:49.131	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.340000	138.064779	NaN	154.500000																																

$	13-Dec-2018	21:03:49.409	DeAnchor	SBE41 Message						   25.35, 22.1241, 35.2028  	25.350000	24.942088	0.046767	-0.010000	-0.005000	0.005107	1.000000																							

$	13-Dec-2018	21:03:50.129	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.350000	137.868263	NaN	154.500000																																

$	13-Dec-2018	21:03:50.408	DeAnchor	SBE41 Message						   25.36, 22.1245, 35.2036  	25.360001	25.040789	0.006084	-0.010000	-0.010000	0.005240	1.000000																							

$	13-Dec-2018	21:03:51.032	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.360001	137.654103	NaN	154.500000																																

$	13-Dec-2018	21:03:51.405	DeAnchor	SBE41 Message						   25.34, 22.1248, 35.2038  	25.340000	25.164904	-0.027205	0.020000	0.005000	0.005319	1.000000																							

$	13-Dec-2018	21:03:52.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.340000	137.548551	NaN	154.500000																																

$	13-Dec-2018	21:03:52.404	DeAnchor	SBE41 Message						   25.36, 22.1251, 35.2051  	25.360001	25.267611	-0.047001	-0.020000	0.000000	0.005356	1.000000																							

$	13-Dec-2018	21:03:53.129	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.360001	137.309872	NaN	154.500000																																

$	13-Dec-2018	21:03:53.405	DeAnchor	SBE41 Message						   25.25, 22.1254, 35.2034  	25.250000	25.323980	-0.055473	0.110001	0.045000	0.005372	1.000000																							

$	13-Dec-2018	21:03:54.031	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	25.250000	137.155205	NaN	154.500000																																

$	13-Dec-2018	21:03:54.403	DeAnchor	SBE41 Message						   24.23, 22.1264, 35.2016  	24.230000	25.344330	-0.058007	1.020000	0.565001	0.005389	1.000000																							

$	13-Dec-2018	21:03:55.129	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.230000	136.904672	NaN	154.500000																																

$	13-Dec-2018	21:03:55.402	DeAnchor	SBE41 Message						   24.00, 22.1268, 35.2030  	24.000000	25.343918	-0.057656	0.230000	0.625000	0.005423	1.000000																							

$	13-Dec-2018	21:03:56.130	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.000000	136.735484	NaN	154.500000																																

$	13-Dec-2018	21:03:56.401	DeAnchor	SBE41 Message						   24.00, 22.1265, 35.2058  	24.000000	25.305062	-0.051058	0.000000	0.115000	0.005515	1.000000																							

$	13-Dec-2018	21:03:57.128	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.000000	136.525311	NaN	154.500000																																

$	13-Dec-2018	21:03:57.400	DeAnchor	SBE41 Message						   24.01, 22.1284, 35.2031  	24.010000	25.167588	-0.027903	-0.010000	-0.005000	0.005807	1.000000																							

$	13-Dec-2018	21:03:58.129	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.010000	136.363015	NaN	154.500000																																

$	13-Dec-2018	21:03:58.398	DeAnchor	SBE41 Message						   24.01, 22.1282, 35.2045  	24.010000	24.888562	0.018813	0.000000	-0.005000	0.006817	1.000000																							

$	13-Dec-2018	21:03:59.034	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.010000	136.237696	NaN	154.500000																																

$	13-Dec-2018	21:03:59.398	DeAnchor	SBE41 Message						   24.01, 22.1286, 35.2056  	24.010000	24.529281	0.078600	0.000000	0.000000	0.013031	1.000000																							

$	13-Dec-2018	21:04:00.128	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.010000	136.096947	NaN	154.500000																																

$	13-Dec-2018	21:04:00.397	DeAnchor	SBE41 Message						   24.00, 22.1286, 35.2039  	24.000000	24.228411	0.128532	0.010000	0.005000	0.014658	1.000000																							

$	13-Dec-2018	21:04:01.129	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.000000	135.893956	NaN	154.500000																																

$	13-Dec-2018	21:04:01.397	DeAnchor	SBE41 Message						   24.02, 22.1281, 35.2065  	24.020000	24.067430	0.155445	-0.020000	-0.005000	0.016584	1.000000																							

$	13-Dec-2018	21:04:02.032	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.020000	135.780230	NaN	154.500000																																

$	13-Dec-2018	21:04:02.395	DeAnchor	SBE41 Message						   24.01, 22.1298, 35.2048  	24.010000	24.016337	0.164307	0.010000	-0.005000	0.018447	1.000000																							

$	13-Dec-2018	21:04:03.033	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.010000	135.724433	NaN	154.500000																																

$	13-Dec-2018	21:04:03.394	DeAnchor	SBE41 Message						   24.03, 22.1293, 35.2054  	24.030001	24.008529	0.165224	-0.020000	-0.005000	0.020322	1.000000																							

$	13-Dec-2018	21:04:04.128	DeAnchor	RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.030001	135.494560	NaN	154.500000																																

$	13-Dec-2018	21:04:04.797	DeAnchor	Deanchor velocity (slope) threshold exceeded

$	13-Dec-2018	21:04:04.394	DeAnchor	SBE41 Message						   24.21, 22.1304, 35.2055  	24.209999	24.008606	0.160385	-0.179998	-0.099999	0.022582	1.000000																							

$	13-Dec-2018	21:04:05.133	DeAnchor	Normal State Exit

$	13-Dec-2018	21:04:05.137	DeAnchor	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	24.209999	135.263026	NaN	154.500000																																

$	13-Dec-2018	21:04:05.798	Ascend	State Entry

$	13-Dec-2018	21:04:05.912	Ascend	Starting valve open

$	13-Dec-2018	21:04:05.917	Ascend	Skipping ascend table depth = 100

$	13-Dec-2018	21:04:06.019	Ascend	Skipping ascend table depth = 95

$	13-Dec-2018	21:04:06.121	Ascend	Skipping ascend table depth = 90

$	13-Dec-2018	21:04:06.223	Ascend	Skipping ascend table depth = 85

$	13-Dec-2018	21:04:06.325	Ascend	Skipping ascend table depth = 80

$	13-Dec-2018	21:04:06.530	Ascend	Skipping ascend table depth = 75

$	13-Dec-2018	21:04:06.632	Ascend	Skipping ascend table depth = 70

$	13-Dec-2018	21:04:06.734	Ascend	Skipping ascend table depth = 65

$	13-Dec-2018	21:04:06.837	Ascend	Skipping ascend table depth = 60

$	13-Dec-2018	21:04:06.939	Ascend	Skipping ascend table depth = 55

$	13-Dec-2018	21:04:07.041	Ascend	Skipping ascend table depth = 50

$	13-Dec-2018	21:04:07.143	Ascend	Skipping ascend table depth = 45

$	13-Dec-2018	21:04:07.149	Ascend	Skipping ascend table depth = 40

$	13-Dec-2018	21:04:07.251	Ascend	Skipping ascend table depth = 35

$	13-Dec-2018	21:04:07.353	Ascend	Skipping ascend table depth = 30

$	13-Dec-2018	21:04:07.457	Ascend	Skipping ascend table depth = 25

$	13-Dec-2018	21:04:07.657	Ascend	Starting ISUS sample

$	13-Dec-2018	21:04:07.760	Ascend	Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00

$	13-Dec-2018	21:04:07.765	Ascend	MSC: OUT: W

$	13-Dec-2018	21:04:08.119	Ascend	MSC: OUT: W

$	13-Dec-2018	21:04:05.393	Ascend	Vel PID Values																		0.050000	-0.100000	-0.099668	-0.099668	0.718404	11.999986	11.999986	98303.000000	1.000000										

$	13-Dec-2018	21:04:05.393	Ascend	SBE41 Message						   24.31, 22.1308, 35.2055  	24.309999	24.010545	0.143108	-0.100000	-0.139999	0.025528	1.000000																							

$	13-Dec-2018	21:04:08.771	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	24.309999	135.066696	NaN	154.500000																																

$	13-Dec-2018	21:04:08.883	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0852161

$	13-Dec-2018	21:04:06.424	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010299	0.089368	1.007841	5.518507	5.518507	45207.000000	1.000000										

$	13-Dec-2018	21:04:06.424	Ascend	SBE41 Message						   24.32, 22.1311, 35.2055  	24.320000	24.019248	0.107499	-0.010000	-0.055000	0.029075	1.000000																							

$	13-Dec-2018	21:04:07.452	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010001	0.000298	1.295844	5.807819	5.807819	47577.000000	1.000000										

$	13-Dec-2018	21:04:07.452	Ascend	SBE41 Message						   24.33, 22.1310, 35.2054  	24.330000	24.046352	0.059709	-0.010000	-0.010000	0.032827	1.000000																							

$	13-Dec-2018	21:04:09.673	Ascend	MSC: RX: 

$	13-Dec-2018	21:04:09.677	Ascend	MSC: RX: 

$	13-Dec-2018	21:04:09.877	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:04:09.978	Ascend	MSC: Got ACK

$	13-Dec-2018	21:04:10.283	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	24.330000	135.015145	NaN	154.500000																																

$	13-Dec-2018	21:04:10.395	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5063956

$	13-Dec-2018	21:04:08.454	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019934	1.488162	4.495835	4.495835	36829.000000	1.000000										

$	13-Dec-2018	21:04:08.454	Ascend	SBE41 Message						   24.32, 22.1306, 35.2042  	24.320000	24.102529	0.015561	0.010000	0.000000	0.036384	1.000000																							

$	13-Dec-2018	21:04:09.388	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000066	1.680162	4.688135	4.688135	38405.000000	1.000000										

$	13-Dec-2018	21:04:09.388	Ascend	SBE41 Message						   24.31, 22.1306, 35.2057  	24.309999	24.180359	-0.013967	0.010000	0.010000	0.039544	1.000000																							

$	13-Dec-2018	21:04:10.394	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019934	1.967843	6.480171	6.480171	53085.000000	1.000000										

$	13-Dec-2018	21:04:10.394	Ascend	SBE41 Message						   24.32, 22.1312, 35.2037  	24.320000	24.253192	-0.029294	-0.010000	0.000000	0.042211	1.000000																							

$	13-Dec-2018	21:04:11.733	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	24.320000	134.964988	NaN	154.500000																																

$	13-Dec-2018	21:04:11.845	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4447356

$	13-Dec-2018	21:04:11.949	Ascend	MSC: OUT: CTD,0,0.0000,0.0000,0.0000

$	13-Dec-2018	21:04:12.265	Ascend	PTH Message														785.014160	23.591667	51.666779	24.579150																			

$	13-Dec-2018	21:04:12.469	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	24.320000	134.910107	31.425000	169.000000																																

$	13-Dec-2018	21:04:11.417	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009901	2.208003	5.967857	5.967857	48888.000000	1.000000										

$	13-Dec-2018	21:04:11.417	Ascend	SBE41 Message						   24.32, 22.1308, 35.2062  	24.320000	24.298860	-0.035914	0.000000	-0.005000	0.044205	1.000000																							

$	13-Dec-2018	21:04:13.193	Ascend	MSC: RX: NAK,CTD,EConvertErr: 0 

$	13-Dec-2018	21:04:13.296	Ascend	MSC: EConvertErr: 0

$	13-Dec-2018	21:04:12.468	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	2.448003	6.207998	6.207998	50855.000000	1.000000										

$	13-Dec-2018	21:04:12.468	Ascend	SBE41 Message						   24.32, 22.1317, 35.2013  	24.320000	24.316702	-0.038118	0.000000	0.000000	0.045206	1.000000																							

$	13-Dec-2018	21:04:13.398	Ascend	Vel PID Values																		0.050000	0.680000	0.677737	0.677737	-0.565137	-47.951720	-47.951720	-392820.000000	1.000000										

$	13-Dec-2018	21:04:13.398	Ascend	SBE41 Message						   23.64, 22.1314, 35.2058  	23.639999	24.319378	-0.038211	0.680000	0.340000	0.045048	1.000000																							

$	13-Dec-2018	21:04:14.288	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.639999	134.809539	31.425000	169.000000																																

$	13-Dec-2018	21:04:14.400	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5499406

$	13-Dec-2018	21:04:14.398	Ascend	Vel PID Values																		0.050000	0.590000	0.590296	-0.087442	-3.158557	-43.765489	-43.765489	-358526.000000	1.000000										

$	13-Dec-2018	21:04:14.398	Ascend	SBE41 Message						   23.05, 22.1317, 35.2063  	23.049999	24.316212	-0.036739	0.590000	0.635000	0.043877	1.000000																							

$	13-Dec-2018	21:04:15.050	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.049999	134.754382	31.425000	169.000000																																

$	13-Dec-2018	21:04:15.406	Ascend	MSC: OUT: W

$	13-Dec-2018	21:04:15.661	Ascend	MSC: OUT: W

$	13-Dec-2018	21:04:15.383	Ascend	Vel PID Values																		0.050000	0.009998	0.011929	-0.578367	-2.975816	0.041359	0.041359	338.000000	1.000000										

$	13-Dec-2018	21:04:15.383	Ascend	SBE41 Message						   23.04, 22.1328, 35.2038  	23.040001	24.295136	-0.030774	0.009998	0.299999	0.042118	1.000000																							

$	13-Dec-2018	21:04:16.011	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:04:16.113	Ascend	MSC: Got ACK

$	13-Dec-2018	21:04:16.515	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.040001	134.747997	31.425000	169.000000																																

$	13-Dec-2018	21:04:16.628	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2223872

$	13-Dec-2018	21:04:16.732	Ascend	MSC: OUT: MODE,1

$	13-Dec-2018	21:04:16.836	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:04:16.840	Ascend	MSC: Got ACK

$	13-Dec-2018	21:04:16.382	Ascend	Vel PID Values																		0.050000	0.010000	0.010003	-0.001925	-2.783832	0.224422	0.224422	1838.000000	1.000000										

$	13-Dec-2018	21:04:16.382	Ascend	SBE41 Message						   23.03, 22.1323, 35.2061  	23.030001	24.206634	-0.012880	0.010000	0.009999	0.040280	1.000000																							

$	13-Dec-2018	21:04:17.385	Ascend	MSC: RX: ACK,MODE,1 

$	13-Dec-2018	21:04:17.383	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009970	-2.543992	1.216164	1.216164	9962.000000	1.000000										

$	13-Dec-2018	21:04:17.383	Ascend	SBE41 Message						   23.03, 22.1325, 35.2023  	23.030001	23.993138	0.023144	0.000000	0.005000	0.038908	1.000000																							

$	13-Dec-2018	21:04:18.034	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.030001	134.734206	31.425000	169.000000																																

$	13-Dec-2018	21:04:18.145	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5113563

$	13-Dec-2018	21:04:18.450	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.030001	134.744845	31.425000	169.000000																																

$	13-Dec-2018	21:04:19.151	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:04:18.378	Ascend	Vel PID Values																		0.050000	-0.019999	-0.019932	-0.019965	-2.208319	3.055888	3.055888	25033.000000	1.000000										

$	13-Dec-2018	21:04:18.378	Ascend	SBE41 Message						   23.05, 22.1338, 35.2059  	23.049999	23.670671	0.072029	-0.019999	-0.009999	0.038438	1.000000																							

$	13-Dec-2018	21:04:19.484	Ascend	Vel PID Values																		0.050000	0.009998	0.009899	0.029831	-2.015832	0.991838	0.991838	8125.000000	1.000000										

$	13-Dec-2018	21:04:19.484	Ascend	SBE41 Message						   23.04, 22.1335, 35.2065  	23.040001	23.351354	0.117180	0.009998	-0.005000	0.039003	1.000000																							

$	13-Dec-2018	21:04:20.148	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.040001	134.753272	31.425000	169.000000																																

$	13-Dec-2018	21:04:20.261	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1105521

$	13-Dec-2018	21:04:20.567	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.040001	134.741478	31.425000	169.000000																																

$	13-Dec-2018	21:04:21.266	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:04:20.377	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009866	-1.775991	1.984150	1.984150	16254.000000	1.000000										

$	13-Dec-2018	21:04:20.377	Ascend	SBE41 Message						   23.04, 22.1337, 35.2031  	23.040001	23.143261	0.145150	0.000000	0.004999	0.040519	1.000000																							

$	13-Dec-2018	21:04:21.386	Ascend	Vel PID Values																		0.050000	-0.009998	-0.009965	-0.009998	-1.488159	3.023875	3.023875	24771.000000	1.000000										

$	13-Dec-2018	21:04:21.386	Ascend	SBE41 Message						   23.05, 22.1339, 35.2050  	23.049999	23.057823	0.156078	-0.009998	-0.004999	0.042815	1.000000																							

$	13-Dec-2018	21:04:22.058	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:04:22.362	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.049999	134.739943	31.425000	169.000000																																

$	13-Dec-2018	21:04:22.474	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2088126

$	13-Dec-2018	21:04:22.473	Ascend	Vel PID Values																		0.050000	0.009998	0.009932	0.019897	-1.295832	1.711989	1.711989	14024.000000	1.000000										

$	13-Dec-2018	21:04:22.473	Ascend	SBE41 Message						   23.04, 22.1342, 35.2068  	23.040001	23.039300	0.157990	0.009998	0.000000	0.045635	1.000000																							

$	13-Dec-2018	21:04:23.125	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.040001	134.742744	31.425000	169.000000																																

$	13-Dec-2018	21:04:23.394	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009899	-1.055991	2.704155	2.704155	22152.000000	1.000000										

$	13-Dec-2018	21:04:23.394	Ascend	SBE41 Message						   23.04, 22.1340, 35.1969  	23.040001	23.039835	0.155304	0.000000	0.004999	0.048631	1.000000																							

$	13-Dec-2018	21:04:24.027	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.040001	134.738900	31.425000	169.000000																																

$	13-Dec-2018	21:04:24.373	Ascend	Vel PID Values																		0.050000	-0.029999	-0.029899	-0.029932	-0.672476	5.343903	5.343903	43777.000000	1.000000										

$	13-Dec-2018	21:04:24.373	Ascend	SBE41 Message						   23.07, 22.1347, 35.2054  	23.070000	23.041937	0.144068	-0.029999	-0.014999	0.051485	1.000000																							

$	13-Dec-2018	21:04:25.027	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.070000	134.710670	31.425000	169.000000																																

$	13-Dec-2018	21:04:25.372	Ascend	Vel PID Values																		0.050000	-0.100000	-0.099767	-0.069868	0.046407	11.327537	11.327537	92795.000000	1.000000										

$	13-Dec-2018	21:04:25.372	Ascend	SBE41 Message						   23.17, 22.1352, 35.2050  	23.170000	23.043067	0.117495	-0.100000	-0.065000	0.054037	1.000000																							

$	13-Dec-2018	21:04:26.027	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.170000	134.738900	31.425000	169.000000																																

$	13-Dec-2018	21:04:26.372	Ascend	Vel PID Values																		0.050000	-0.030001	-0.030233	0.069534	0.431526	6.446524	6.446524	52809.000000	1.000000										

$	13-Dec-2018	21:04:26.372	Ascend	SBE41 Message						   23.20, 22.1354, 35.2065  	23.200001	23.044285	0.077450	-0.030001	-0.065001	0.056242	1.000000																							

$	13-Dec-2018	21:04:27.028	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.200001	134.731315	31.425000	169.000000																																

$	13-Dec-2018	21:04:27.369	Ascend	Vel PID Values																		0.050000	0.000000	-0.000100	0.030133	0.672007	4.431509	4.431509	36302.000000	1.000000										

$	13-Dec-2018	21:04:27.369	Ascend	SBE41 Message						   23.20, 22.1355, 35.2064  	23.200001	23.049595	0.037306	0.000000	-0.015000	0.058077	1.000000																							

$	13-Dec-2018	21:04:28.026	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.200001	134.742357	31.425000	169.000000																																

$	13-Dec-2018	21:04:28.369	Ascend	Vel PID Values																		0.050000	-0.009998	-0.009965	-0.009865	0.959840	5.471855	5.471855	44825.000000	1.000000										

$	13-Dec-2018	21:04:28.369	Ascend	SBE41 Message						   23.21, 22.1363, 35.2059  	23.209999	23.066614	0.009474	-0.009998	-0.004999	0.059451	1.000000																							

$	13-Dec-2018	21:04:28.729	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:04:29.131	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.209999	134.727336	31.425000	169.000000																																

$	13-Dec-2018	21:04:29.367	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009932	1.200000	4.959849	4.959849	40631.000000	1.000000										

$	13-Dec-2018	21:04:29.367	Ascend	SBE41 Message						   23.21, 22.1354, 35.2066  	23.209999	23.099650	-0.005172	0.000000	-0.004999	0.060171	1.000000																							

$	13-Dec-2018	21:04:30.028	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.209999	134.735882	31.425000	169.000000																																

$	13-Dec-2018	21:04:30.483	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:04:30.368	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	1.440000	5.199995	5.199995	42598.000000	1.000000										

$	13-Dec-2018	21:04:30.368	Ascend	SBE41 Message						   23.21, 22.1365, 35.2058  	23.209999	23.141003	-0.012576	0.000000	0.000000	0.060014	1.000000																							

$	13-Dec-2018	21:04:31.328	Ascend	Error in I2CPortBase.Execute

$	13-Dec-2018	21:04:31.333	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.209999	134.735882	31.425000	169.000000																																

$	13-Dec-2018	21:04:31.541	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0588183

$	13-Dec-2018	21:04:31.847	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.209999	134.735912	31.425000	169.000000																																

$	13-Dec-2018	21:04:32.549	Ascend	MSC: RX: 0x117A,A,02/01/2012 03:29:37,0,-1.00,-1.0000,-1.0000,251,163,1,66,22.34,54.72,11.576,5.260e-01,10703.00,2274.00,1164.37,12.96,-29EC486B463F43B1411D3F293DF43D883DFA3F47416D449848A34DE053CC5A80617368636F12748D787F7ABE7B437A32778973B76FA06B546769641C61665FAB5EE85F20601861D8646267BC6BDE708675D27BBC81BD87998D499251967999419AD29AB498D3957590CC8B1F848D7E03778D71376B77664461A25DA25A3D574954BD52DA5156501D4F604EEF4EFF,6747.4 

$	13-Dec-2018	21:04:32.659	Ascend	MSC: Data: 0x117A,A,02/01/2012 03:29:37,0,-1.00,-1.0000,-1.0000,251,163,1,66,22.34,54.72,11.576,5.260e-01,10703.00,2274.00,1164.37,12.96,-29EC486B463F43B1411D3F293DF43D883DFA3F47416D449848A34DE053CC5A80617368636F12748D787F7ABE7B437A32778973B76FA06B546769641C61665FAB5EE85F20601861D8646267BC6BDE708675D27BBC81BD87998D499251967999419AD29AB498D3957590CC8B1F848D7E03778D71376B77664461A25DA25A3D574954BD52DA5156501D4F604EEF4EFF,6747.4 

$	13-Dec-2018	21:04:32.771	Ascend	MSC post: 6747.4

$	13-Dec-2018	21:04:31.720	Ascend	Vel PID Values																		0.050000	0.009998	0.009965	0.009965	1.632168	4.640139	4.640139	38012.000000	1.000000										

$	13-Dec-2018	21:04:31.720	Ascend	SBE41 Message						   23.20, 22.1368, 35.2057  	23.200001	23.175838	-0.016821	0.009998	0.004999	0.058796	1.000000																							

$	13-Dec-2018	21:04:32.364	Ascend	Vel PID Values																		0.050000	-0.009998	-0.009932	-0.019897	1.919841	6.432020	6.432020	52691.000000	1.000000										

$	13-Dec-2018	21:04:32.364	Ascend	SBE41 Message						   23.21, 22.1369, 35.2063  	23.209999	23.196223	-0.019086	-0.009998	0.000000	0.056843	1.000000																							

$	13-Dec-2018	21:04:33.448	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009899	2.160000	5.919854	5.919854	48495.000000	1.000000										

$	13-Dec-2018	21:04:33.448	Ascend	SBE41 Message						   23.21, 22.1364, 35.2073  	23.209999	23.204887	-0.020021	0.000000	-0.004999	0.054229	1.000000																							

$	13-Dec-2018	21:04:34.018	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.209999	134.743676	31.425000	169.000000																																

$	13-Dec-2018	21:04:34.130	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5819270

$	13-Dec-2018	21:04:34.233	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:04:34.237	Ascend	Starting pH sample

$	13-Dec-2018	21:04:34.339	Ascend	MSC: OUT: W

$	13-Dec-2018	21:04:34.789	Ascend	MSC: OUT: W

$	13-Dec-2018	21:04:34.437	Ascend	Vel PID Values																		0.050000	0.049999	0.049833	0.049866	2.160802	2.160079	2.160079	17695.000000	1.000000										

$	13-Dec-2018	21:04:34.437	Ascend	SBE41 Message						   23.16, 22.1369, 35.2071  	23.160000	23.207457	-0.020188	0.049999	0.025000	0.051135	1.000000																							

$	13-Dec-2018	21:04:35.139	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:04:35.240	Ascend	MSC: Got ACK

$	13-Dec-2018	21:04:35.643	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	23.160000	134.733334	31.425000	169.000000																																

$	13-Dec-2018	21:04:35.756	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6209892

$	13-Dec-2018	21:04:35.859	Ascend	MSC: OUT: MODE,2

$	13-Dec-2018	21:04:35.964	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:04:35.968	Ascend	MSC: Got ACK

$	13-Dec-2018	21:04:35.457	Ascend	Vel PID Values																		0.050000	0.879999	0.877237	0.827404	425.353610	-64.238785	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:35.457	Ascend	SBE41 Message						   22.28, 22.1368, 35.2073  	22.280001	23.207307	-0.019511	0.879999	0.464999	0.047639	1.000000																							

$	13-Dec-2018	21:04:36.512	Ascend	MSC: RX: ACK,MODE,2 

$	13-Dec-2018	21:04:36.398	Ascend	Vel PID Values																		0.050000	0.320002	0.321861	-0.555376	-10188.537335	403.752867	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:36.398	Ascend	SBE41 Message						   21.96, 22.1365, 35.2073  	21.959999	23.202997	-0.016869	0.320002	0.600000	0.043923	1.000000																							

$	13-Dec-2018	21:04:37.171	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.756967	31.425000	169.000000																																

$	13-Dec-2018	21:04:37.282	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5208638

$	13-Dec-2018	21:04:37.386	Ascend	Vel PID Values																		0.050000	-0.010000	-0.008899	-0.330759	293823.861876	-10183.737217	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:37.386	Ascend	SBE41 Message						   21.97, 22.1365, 35.2077  	21.969999	23.172520	-0.009013	-0.010000	0.155001	0.040454	1.000000																							

$	13-Dec-2018	21:04:37.955	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.730704	31.425000	169.000000																																

$	13-Dec-2018	21:04:38.289	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:04:38.393	Ascend	Vel PID Values																		0.050000	0.010000	0.009936	0.018834	-8519487.806217	293827.062013	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:38.393	Ascend	SBE41 Message						   21.96, 22.1366, 35.2073  	21.959999	23.059453	0.010079	0.010000	0.000000	0.038094	1.000000																							

$	13-Dec-2018	21:04:38.940	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.753443	31.425000	169.000000																																

$	13-Dec-2018	21:04:39.491	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.738356	31.425000	169.000000																																

$	13-Dec-2018	21:04:40.289	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:04:39.357	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019869	247063502.667951	-8519483.006216	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:39.357	Ascend	SBE41 Message						   21.97, 22.1369, 35.2070  	21.969999	22.817064	0.044357	-0.010000	0.000000	0.037661	1.000000																							

$	13-Dec-2018	21:04:40.391	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009901	-7164840197.130829	247063506.667965	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:40.391	Ascend	SBE41 Message						   21.97, 22.1373, 35.2077  	21.969999	22.489534	0.087384	0.000000	-0.005000	0.039257	1.000000																							

$	13-Dec-2018	21:04:41.080	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:04:41.387	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.719647	31.425000	169.000000																																

$	13-Dec-2018	21:04:41.498	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2095037

$	13-Dec-2018	21:04:41.356	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010000	207780364120.986760	-7164840193.930847	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:41.356	Ascend	SBE41 Message						   21.96, 22.1379, 35.2072  	21.959999	22.200806	0.124182	0.010000	0.005000	0.042204	1.000000																							

$	13-Dec-2018	21:04:42.147	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.508982	31.425000	169.000000																																

$	13-Dec-2018	21:04:42.354	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019901	-6025630558152.329100	207780364125.786770	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:42.354	Ascend	SBE41 Message						   21.97, 22.1388, 35.2071  	21.969999	22.035906	0.144925	-0.010000	0.000000	0.045604	1.000000																							

$	13-Dec-2018	21:04:43.055	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.394765	31.425000	169.000000																																

$	13-Dec-2018	21:04:43.354	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019868	174743286184821.750000	-6025630558149.128900	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:43.354	Ascend	SBE41 Message						   21.96, 22.1382, 35.2078  	21.959999	21.978110	0.152081	0.010000	0.000000	0.048876	1.000000																							

$	13-Dec-2018	21:04:44.053	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.403072	31.425000	169.000000																																

$	13-Dec-2018	21:04:44.352	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009901	-5067555299358450.000000	174743286184825.750000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:44.352	Ascend	SBE41 Message						   21.96, 22.1390, 35.2061  	21.959999	21.967333	0.152886	0.000000	0.005000	0.051809	1.000000																							

$	13-Dec-2018	21:04:45.052	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.382926	31.425000	169.000000																																

$	13-Dec-2018	21:04:45.352	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	146959103681393380.000000	-5067555299358445.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:45.352	Ascend	SBE41 Message						   21.97, 22.1387, 35.2076  	21.969999	21.966376	0.149216	-0.010000	-0.005000	0.054358	1.000000																							

$	13-Dec-2018	21:04:46.049	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.366632	31.425000	169.000000																																

$	13-Dec-2018	21:04:46.350	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000033	-4261814006760406000.000000	146959103681393380.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:46.350	Ascend	SBE41 Message						   21.98, 22.1395, 35.2039  	21.980000	21.965564	0.135301	-0.010000	-0.010000	0.056485	1.000000																							

$	13-Dec-2018	21:04:47.050	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.980000	134.388745	31.425000	169.000000																																

$	13-Dec-2018	21:04:47.348	Ascend	Vel PID Values																		0.050000	0.020000	0.019901	0.029901	123592606196051770000.000000	-4261814006760406000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:47.348	Ascend	SBE41 Message						   21.96, 22.1396, 35.2072  	21.959999	21.964493	0.105431	0.020000	0.005000	0.058118	1.000000																							

$	13-Dec-2018	21:04:48.052	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.379752	31.425000	169.000000																																

$	13-Dec-2018	21:04:48.349	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009901	-0.029801	-3584185579685501500000.000000	123592606196051770000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:48.349	Ascend	SBE41 Message						   21.97, 22.1398, 35.2073  	21.969999	21.964162	0.064958	-0.010000	0.005000	0.059144	1.000000																							

$	13-Dec-2018	21:04:49.052	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.370834	31.425000	169.000000																																

$	13-Dec-2018	21:04:49.347	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009867	103941381810879530000000.000000	-3584185579685501500000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:49.347	Ascend	SBE41 Message						   21.97, 22.1406, 35.2068  	21.969999	21.965486	0.029092	0.000000	-0.005000	0.059481	1.000000																							

$	13-Dec-2018	21:04:50.053	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.366490	31.425000	169.000000																																

$	13-Dec-2018	21:04:50.348	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	-3014300072515506400000000.000000	103941381810879530000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:50.348	Ascend	SBE41 Message						   21.97, 22.1409, 35.2069  	21.969999	21.967830	0.008415	0.000000	0.000000	0.059110	1.000000																							

$	13-Dec-2018	21:04:51.055	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.363607	31.425000	169.000000																																

$	13-Dec-2018	21:04:51.507	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:04:51.346	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	87414702102949676000000000.000000	-3014300072515506400000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:51.346	Ascend	SBE41 Message						   21.97, 22.1414, 35.2045  	21.969999	21.969231	0.001098	0.000000	0.000000	0.058123	1.000000																							

$	13-Dec-2018	21:04:52.157	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.359218	31.425000	169.000000																																

$	13-Dec-2018	21:04:52.344	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009967	-2535026360985540900000000000.000000	87414702102949676000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:52.344	Ascend	SBE41 Message						   21.98, 22.1411, 35.2055  	21.980000	21.969105	-0.000219	-0.010000	-0.005000	0.056620	1.000000																							

$	13-Dec-2018	21:04:53.054	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.980000	134.392202	31.425000	169.000000																																

$	13-Dec-2018	21:04:53.507	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:04:53.342	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009934	73515764468580685000000000000.000000	-2535026360985540900000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:53.342	Ascend	SBE41 Message						   21.98, 22.1414, 35.2074  	21.980000	21.968851	-0.000307	0.000000	-0.005000	0.054678	1.000000																							

$	13-Dec-2018	21:04:54.157	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.980000	134.367526	31.425000	169.000000																																

$	13-Dec-2018	21:04:54.507	Ascend	MSC: RX: 0x6318,pH,02/01/2012 03:30:01,0,-1.00,-1.0000,-1.0000,276,163,0,22.34,54.72,11.744,4.640e-02,7.1234,0.000,-1.014842,0.001059,-1.,+3.232e-08,+2.022e-07 

$	13-Dec-2018	21:04:54.513	Ascend	MSC: Data: 0x6318,pH,02/01/2012 03:30:01,0,-1.00,-1.0000,-1.0000,276,163,0,22.34,54.72,11.744,4.640e-02,7.1234,0.000,-1.014842,0.001059,-1.,+3.232e-08,+2.022e-07 

$	13-Dec-2018	21:04:54.717	Ascend	MSC post: 7.1234

$	13-Dec-2018	21:04:54.343	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010000	-2131957169588839900000000000000.000000	73515764468580685000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:54.343	Ascend	SBE41 Message						   21.97, 22.1413, 35.2068  	21.969999	21.969522	-0.000490	0.010000	0.005000	0.052302	1.000000																							

$	13-Dec-2018	21:04:55.367	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.381413	31.425000	169.000000																																

$	13-Dec-2018	21:04:55.506	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:04:55.608	Ascend	MSC: OUT: SLP

$	13-Dec-2018	21:04:55.342	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019901	-0.029868	61826757918076358000000000000000.000000	-2131957169588839900000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:55.342	Ascend	SBE41 Message						   21.99, 22.1419, 35.2067  	21.990000	21.971099	-0.000817	-0.020000	-0.005000	0.049559	1.000000																							

$	13-Dec-2018	21:04:56.260	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.990000	134.362064	31.425000	169.000000																																

$	13-Dec-2018	21:04:56.507	Ascend	MSC: RX: ACK,SLP 

$	13-Dec-2018	21:04:56.371	Ascend	Vel PID Values																		0.050000	0.020000	0.019868	0.039768	-1792975979624214400000000000000000.000000	61826757918076358000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:56.371	Ascend	SBE41 Message						   21.97, 22.1424, 35.2069  	21.969999	21.973317	-0.001132	0.020000	0.000000	0.046705	1.000000																							

$	13-Dec-2018	21:04:57.157	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.969999	134.376787	31.425000	169.000000																																

$	13-Dec-2018	21:04:57.340	Ascend	Vel PID Values																		0.050000	0.010000	0.010033	-0.009834	51996303409102213000000000000000000.000000	-1792975979624214400000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:57.340	Ascend	SBE41 Message						   21.96, 22.1424, 35.2065  	21.959999	21.975582	-0.001248	0.010000	0.015000	0.044252	1.000000																							

$	13-Dec-2018	21:04:58.053	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.959999	134.383991	31.425000	169.000000																																

$	13-Dec-2018	21:04:58.338	Ascend	Vel PID Values																		0.050000	0.240000	0.239234	0.229201	-1507892798863964200000000000000000000.000000	51996303409102213000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:04:58.338	Ascend	SBE41 Message						   21.72, 22.1432, 35.2065  	21.719999	21.977125	-0.001150	0.240000	0.125000	0.042659	1.000000																							

$	13-Dec-2018	21:04:59.054	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	21.719999	134.353139	31.425000	169.000000																																

$	13-Dec-2018	21:04:59.337	Ascend	Vel PID Values																		0.050000	0.820000	0.818068	0.578834	43728891167054960000000000000000000000.000000	-1507892798863964200000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:04:59.337	Ascend	SBE41 Message						   20.90, 22.1433, 35.2076  	20.900000	21.976688	-0.000923	0.820000	0.530000	0.041963	1.000000																							

$	13-Dec-2018	21:05:00.054	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.900000	134.362034	31.425000	169.000000																																

$	13-Dec-2018	21:05:00.337	Ascend	Vel PID Values																		0.050000	0.129999	0.132292	-0.685776	-1268137843844593800000000000000000000000.000000	43728891167054960000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:00.337	Ascend	SBE41 Message						   20.77, 22.1437, 35.2070  	20.770000	21.965665	0.000424	0.129999	0.474999	0.041870	1.000000																							

$	13-Dec-2018	21:05:01.053	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.347931	31.425000	169.000000																																

$	13-Dec-2018	21:05:01.337	Ascend	Vel PID Values																		0.050000	0.000000	0.000436	-0.131856	36775997471493222000000000000000000000000.000000	-1268137843844593800000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:01.337	Ascend	SBE41 Message						   20.77, 22.1430, 35.2081  	20.770000	21.912076	0.007017	0.000000	0.065000	0.042080	1.000000																							

$	13-Dec-2018	21:05:02.053	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.339929	31.425000	169.000000																																

$	13-Dec-2018	21:05:02.334	Ascend	Vel PID Values																		0.050000	0.000000	0.000001	-0.000436	-1066503926673303400000000000000000000000000.000000	36775997471493222000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:02.334	Ascend	SBE41 Message						   20.77, 22.1430, 35.2075  	20.770000	21.762080	0.025645	0.000000	0.000000	0.042677	1.000000																							

$	13-Dec-2018	21:05:03.051	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.342514	31.425000	169.000000																																

$	13-Dec-2018	21:05:03.333	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009966	30928613873525800000000000000000000000000000.000000	-1066503926673303400000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:03.333	Ascend	SBE41 Message						   20.76, 22.1427, 35.2066  	20.760000	21.495232	0.058837	0.010000	0.005000	0.044026	1.000000																							

$	13-Dec-2018	21:05:04.053	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.760000	134.348221	31.425000	169.000000																																

$	13-Dec-2018	21:05:04.332	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	-896929802332248200000000000000000000000000000.000000	30928613873525800000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:04.332	Ascend	SBE41 Message						   20.76, 22.1440, 35.2072  	20.760000	21.181837	0.097876	0.000000	0.005000	0.046232	1.000000																							

$	13-Dec-2018	21:05:05.053	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.760000	134.330012	31.425000	169.000000																																

$	13-Dec-2018	21:05:05.332	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	26010964267635200000000000000000000000000000000.000000	-896929802332248200000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:05.332	Ascend	SBE41 Message						   20.77, 22.1447, 35.2068  	20.770000	20.937240	0.128428	-0.010000	-0.005000	0.048981	1.000000																							

$	13-Dec-2018	21:05:06.053	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.357855	31.425000	169.000000																																

$	13-Dec-2018	21:05:06.330	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019901	-754317963761420850000000000000000000000000000000.000000	26010964267635200000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:06.330	Ascend	SBE41 Message						   20.76, 22.1448, 35.2073  	20.760000	20.812854	0.144033	0.010000	0.000000	0.051788	1.000000																							

$	13-Dec-2018	21:05:07.054	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.760000	134.346545	31.425000	169.000000																																

$	13-Dec-2018	21:05:07.331	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019868	21875220949081207000000000000000000000000000000000.000000	-754317963761420850000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:07.331	Ascend	SBE41 Message						   20.77, 22.1442, 35.2081  	20.770000	20.773166	0.148906	-0.010000	0.000000	0.054300	1.000000																							

$	13-Dec-2018	21:05:08.055	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.357221	31.425000	169.000000																																

$	13-Dec-2018	21:05:08.328	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000066	-634381407523355010000000000000000000000000000000000.000000	21875220949081207000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:08.328	Ascend	SBE41 Message						   20.78, 22.1450, 35.2074  	20.780001	20.765097	0.148538	-0.010000	-0.010000	0.056348	1.000000																							

$	13-Dec-2018	21:05:09.055	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.780001	134.359941	31.425000	169.000000																																

$	13-Dec-2018	21:05:09.327	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019934	18397060818177296000000000000000000000000000000000000.000000	-634381407523355010000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:09.327	Ascend	SBE41 Message						   20.77, 22.1447, 35.2066  	20.770000	20.763943	0.142030	0.010000	0.000000	0.057840	1.000000																							

$	13-Dec-2018	21:05:10.055	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.376042	31.425000	169.000000																																

$	13-Dec-2018	21:05:10.326	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000066	-533514763727141580000000000000000000000000000000000000.000000	18397060818177296000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:10.326	Ascend	SBE41 Message						   20.76, 22.1458, 35.2071  	20.760000	20.764776	0.123347	0.010000	0.010000	0.058729	1.000000																							

$	13-Dec-2018	21:05:11.056	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.760000	134.382032	31.425000	169.000000																																

$	13-Dec-2018	21:05:11.325	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019901	-0.029901	15471928148087106000000000000000000000000000000000000000.000000	-533514763727141580000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:11.325	Ascend	SBE41 Message						   20.78, 22.1461, 35.2072  	20.780001	20.766888	0.090065	-0.020000	-0.005000	0.058947	1.000000																							

$	13-Dec-2018	21:05:12.056	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.780001	134.401344	31.425000	169.000000																																

$	13-Dec-2018	21:05:12.324	Ascend	Vel PID Values																		0.050000	0.000000	-0.000066	0.019834	-448685916294526120000000000000000000000000000000000000000.000000	15471928148087106000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:12.324	Ascend	SBE41 Message						   20.78, 22.1462, 35.2076  	20.780001	20.769437	0.050988	0.000000	-0.010000	0.058699	1.000000																							

$	13-Dec-2018	21:05:13.055	Ascend	PTH Message														778.226074	23.691667	51.750702	24.568425																			

$	13-Dec-2018	21:05:13.257	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.780001	134.415694	29.750000	194.000000																																

$	13-Dec-2018	21:05:13.368	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009901	13011891572541258000000000000000000000000000000000000000000.000000	-448685916294526120000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:13.368	Ascend	SBE41 Message						   20.79, 22.1457, 35.2080  	20.790001	20.770944	0.020558	-0.010000	-0.005000	0.057929	1.000000																							

$	13-Dec-2018	21:05:14.056	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.790001	134.509571	29.750000	194.000000																																

$	13-Dec-2018	21:05:14.322	Ascend	Vel PID Values																		0.050000	0.020000	0.019901	0.029868	-377344855603696500000000000000000000000000000000000000000000.000000	13011891572541258000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:14.322	Ascend	SBE41 Message						   20.77, 22.1467, 35.2076  	20.770000	20.771129	0.005157	0.020000	0.005000	0.056704	1.000000																							

$	13-Dec-2018	21:05:15.056	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.622313	29.750000	194.000000																																

$	13-Dec-2018	21:05:15.319	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019868	-0.039768	10943000812507198000000000000000000000000000000000000000000000.000000	-377344855603696500000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:15.319	Ascend	SBE41 Message						   20.79, 22.1468, 35.2042  	20.790001	20.772091	0.000132	-0.020000	0.000000	0.055016	1.000000																							

$	13-Dec-2018	21:05:16.057	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.790001	134.875178	29.750000	194.000000																																

$	13-Dec-2018	21:05:16.320	Ascend	Vel PID Values																		0.050000	0.020000	0.019868	0.039735	-317347023562708760000000000000000000000000000000000000000000000.000000	10943000812507198000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:16.320	Ascend	SBE41 Message						   20.77, 22.1468, 35.2081  	20.770000	20.775282	-0.001260	0.020000	0.000000	0.052884	1.000000																							

$	13-Dec-2018	21:05:17.057	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.891778	29.750000	194.000000																																

$	13-Dec-2018	21:05:17.319	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009901	-0.029768	9203063683318554200000000000000000000000000000000000000000000000.000000	-317347023562708760000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:17.319	Ascend	SBE41 Message						   20.78, 22.1463, 35.2082  	20.780001	20.778980	-0.001860	-0.010000	0.005000	0.050403	1.000000																							

$	13-Dec-2018	21:05:18.056	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.780001	134.913750	29.750000	194.000000																																

$	13-Dec-2018	21:05:18.319	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019834	-266888846816238090000000000000000000000000000000000000000000000000.000000	9203063683318554200000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:18.319	Ascend	SBE41 Message						   20.77, 22.1468, 35.2070  	20.770000	20.780779	-0.001979	0.010000	0.000000	0.047899	1.000000																							

$	13-Dec-2018	21:05:19.059	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.970456	29.750000	194.000000																																

$	13-Dec-2018	21:05:19.317	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009901	7739776557670903400000000000000000000000000000000000000000000000000.000000	-266888846816238090000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:19.317	Ascend	SBE41 Message						   20.77, 22.1470, 35.2081  	20.770000	20.780477	-0.001681	0.000000	0.005000	0.045906	1.000000																							

$	13-Dec-2018	21:05:20.059	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.770000	134.962879	29.750000	194.000000																																

$	13-Dec-2018	21:05:20.316	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	-224453520172456190000000000000000000000000000000000000000000000000000.000000	7739776557670903400000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:20.316	Ascend	SBE41 Message						   20.78, 22.1475, 35.2083  	20.780001	20.779124	-0.001199	-0.010000	-0.005000	0.044792	1.000000																							

$	13-Dec-2018	21:05:21.060	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.780001	134.980731	29.750000	194.000000																																

$	13-Dec-2018	21:05:21.314	Ascend	Vel PID Values																		0.050000	0.020000	0.019901	0.029868	6509152085001229600000000000000000000000000000000000000000000000000000.000000	-224453520172456190000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:21.314	Ascend	SBE41 Message						   20.76, 22.1484, 35.2078  	20.760000	20.777277	-0.000784	0.020000	0.005000	0.044479	1.000000																							

$	13-Dec-2018	21:05:22.060	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.760000	135.097966	29.750000	194.000000																																

$	13-Dec-2018	21:05:22.313	Ascend	Vel PID Values																		0.050000	0.730000	0.727637	0.707736	-188765410465035660000000000000000000000000000000000000000000000000000000.000000	6509152085001229600000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:22.313	Ascend	SBE41 Message						   20.03, 22.1487, 35.2084  	20.030001	20.775241	-0.000509	0.730000	0.375000	0.044542	1.000000																							

$	13-Dec-2018	21:05:23.060	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	20.030001	135.109939	29.750000	194.000000																																

$	13-Dec-2018	21:05:23.313	Ascend	Vel PID Values																		0.050000	0.500000	0.500761	-0.226875	5474196903486034300000000000000000000000000000000000000000000000000000000.000000	-188765410465035660000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:23.313	Ascend	SBE41 Message						   19.53, 22.1484, 35.2068  	19.530001	20.771369	0.000089	0.500000	0.615000	0.044605	1.000000																							

$	13-Dec-2018	21:05:24.061	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16  Pres, BP, BatV, BatI: 	19.530001	135.130994	29.750000	194.000000																																

$	13-Dec-2018	21:05:24.522	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:05:24.526	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:05:25.128	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:05:25.145	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:05:25.247	Ascend	Sending FLBB run command

$	13-Dec-2018	21:05:25.349	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:05:25.454	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:05:25.660	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:05:25.775	Ascend	CTD post: 19.52	22.149	35.21

$	13-Dec-2018	21:05:24.311	Ascend	Vel PID Values																		0.050000	0.010000	0.011632	-0.489129	-158751710201094990000000000000000000000000000000000000000000000000000000000.000000	5474196903486034300000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:24.311	Ascend	SBE41 Message						   19.52, 22.1490, 35.2080  	19.520000	20.747748	0.003404	0.010000	0.255000	0.044569	1.000000																							

$	13-Dec-2018	21:05:25.346	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009931	-0.021563	4603799595831754900000000000000000000000000000000000000000000000000000000000.000000	-158751710201094990000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:25.346	Ascend	SBE41 Message						   19.53, 22.1492, 35.2056  	19.530001	20.653057	0.015567	-0.010000	0.000000	0.044647	1.000000																							

$	13-Dec-2018	21:05:26.462	Ascend	Radiometer Message																																	SATFI40287,-0.0046,0.0003,-0.0094,-0.2210 			

$	13-Dec-2018	21:05:26.677	Ascend	Radiometer post: SATFI40287,-0.0046,0.0003,-0.0094,-0.2210 

$	13-Dec-2018	21:05:26.229	Ascend	Optode Message																												%!4330,1532,265.610,22.429,29.145,29.075,36.121,7.045,531.0,464.5,112.6  								

$	13-Dec-2018	21:05:26.896	Ascend	Optode post: %!4330,1532,265.610,22.429,29.145,29.075,36.121,7.045,531.0,464.5,112.6  

$	13-Dec-2018	21:05:26.230	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:05:27.313	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.530001	135.135636	29.750000	194.000000																																

$	13-Dec-2018	21:05:27.425	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9131151

$	13-Dec-2018	21:05:27.432	Ascend	Starting ISUS sample

$	13-Dec-2018	21:05:27.632	Ascend	Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00

$	13-Dec-2018	21:05:27.638	Ascend	MSC: OUT: W

$	13-Dec-2018	21:05:28.087	Ascend	MSC: OUT: W

$	13-Dec-2018	21:05:26.310	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009898	-133510188279120870000000000000000000000000000000000000000000000000000000000000.000000	4603799595831754900000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:26.310	Ascend	SBE41 Message						   19.53, 22.1496, 35.2082  	19.530001	20.433761	0.042903	0.000000	-0.005000	0.045292	1.000000																							

$	13-Dec-2018	21:05:28.445	Ascend	FLBB Message																											/99/99,99:99:99,695,2314,700,4130,533  									

$	13-Dec-2018	21:05:28.653	Ascend	FLBB post: /99/99,99:99:99,695,2314,700,4130,533  

$	13-Dec-2018	21:05:27.309	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	3871795460094505000000000000000000000000000000000000000000000000000000000000000.000000	-133510188279120870000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:27.309	Ascend	SBE41 Message						   19.53, 22.1495, 35.2083  	19.530001	20.114165	0.082389	0.000000	0.000000	0.046824	1.000000																							

$	13-Dec-2018	21:05:29.004	Ascend	MSC: RX: 

$	13-Dec-2018	21:05:29.107	Ascend	MSC: RX: 

$	13-Dec-2018	21:05:29.308	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:05:29.409	Ascend	MSC: Got ACK

$	13-Dec-2018	21:05:28.313	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	-112282068342740640000000000000000000000000000000000000000000000000000000000000000.000000	3871795460094505000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:28.313	Ascend	SBE41 Message						   19.53, 22.1489, 35.2083  	19.530001	19.809164	0.119957	0.000000	0.000000	0.049125	1.000000																							

$	13-Dec-2018	21:05:30.060	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.530001	136.182860	29.750000	194.000000																																

$	13-Dec-2018	21:05:30.171	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7392652

$	13-Dec-2018	21:05:29.409	Ascend	Vel PID Values																		0.050000	0.020000	0.019934	0.019934	3256179981939478500000000000000000000000000000000000000000000000000000000000000000.000000	-112282068342740640000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:29.409	Ascend	SBE41 Message						   19.51, 22.1486, 35.2090  	19.510000	19.619052	0.143271	0.020000	0.010000	0.051704	1.000000																							

$	13-Dec-2018	21:05:30.824	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.510000	136.688307	29.750000	194.000000																																

$	13-Dec-2018	21:05:31.179	Ascend	MSC: OUT: CTD,0,0.0000,0.0000,0.0000

$	13-Dec-2018	21:05:30.306	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009901	-0.029834	-94429219476244879000000000000000000000000000000000000000000000000000000000000000000.000000	3256179981939478500000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:30.306	Ascend	SBE41 Message						   19.52, 22.1489, 35.2092  	19.520000	19.545460	0.152149	-0.010000	0.005000	0.054112	1.000000																							

$	13-Dec-2018	21:05:31.311	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000100	2738447364811101700000000000000000000000000000000000000000000000000000000000000000000.000000	-94429219476244879000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:31.311	Ascend	SBE41 Message						   19.53, 22.1494, 35.2088  	19.530001	19.529832	0.153613	-0.010000	-0.010000	0.056116	1.000000																							

$	13-Dec-2018	21:05:31.991	Ascend	MSC: RX: NAK,CTD,EConvertErr: 0 

$	13-Dec-2018	21:05:32.094	Ascend	MSC: EConvertErr: 0

$	13-Dec-2018	21:05:32.398	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.530001	136.677995	29.750000	194.000000																																

$	13-Dec-2018	21:05:32.510	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3329269

$	13-Dec-2018	21:05:32.304	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000000	-79414973579521946000000000000000000000000000000000000000000000000000000000000000000000.000000	2738447364811101700000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:32.304	Ascend	SBE41 Message						   19.54, 22.1500, 35.2067  	19.540001	19.527306	0.150989	-0.010000	-0.010000	0.057674	1.000000																							

$	13-Dec-2018	21:05:33.167	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.540001	137.111507	29.750000	194.000000																																

$	13-Dec-2018	21:05:33.518	Ascend	MSC: OUT: W

$	13-Dec-2018	21:05:33.773	Ascend	MSC: OUT: W

$	13-Dec-2018	21:05:33.302	Ascend	Vel PID Values																		0.050000	-0.089998	-0.089732	-0.079732	2303034233806136800000000000000000000000000000000000000000000000000000000000000000000000.000000	-79414973579521946000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:33.302	Ascend	SBE41 Message						   19.63, 22.1497, 35.2075  	19.629999	19.524496	0.139595	-0.089998	-0.049999	0.058785	1.000000																							

$	13-Dec-2018	21:05:34.126	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:05:34.326	Ascend	MSC: Got ACK

$	13-Dec-2018	21:05:34.428	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:05:34.531	Ascend	MSC: Got ACK

$	13-Dec-2018	21:05:34.325	Ascend	Vel PID Values																		0.050000	-0.090000	-0.090000	-0.000268	-66787992780377957000000000000000000000000000000000000000000000000000000000000000000000000.000000	2303034233806136800000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:34.325	Ascend	SBE41 Message						   19.72, 22.1501, 35.2085  	19.719999	19.522759	0.112661	-0.090000	-0.089999	0.059436	1.000000																							

$	13-Dec-2018	21:05:35.182	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.719999	137.242608	29.750000	194.000000																																

$	13-Dec-2018	21:05:35.294	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7771653

$	13-Dec-2018	21:05:35.398	Ascend	MSC: OUT: MODE,1

$	13-Dec-2018	21:05:35.397	Ascend	Vel PID Values																		0.050000	-0.040001	-0.040167	0.049832	1936851790630960600000000000000000000000000000000000000000000000000000000000000000000000000.000000	-66787992780377957000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:35.397	Ascend	SBE41 Message						   19.76, 22.1503, 35.2055  	19.760000	19.527214	0.072574	-0.040001	-0.065001	0.059591	1.000000																							

$	13-Dec-2018	21:05:36.054	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.760000	137.243547	29.750000	194.000000																																

$	13-Dec-2018	21:05:36.302	Ascend	MSC: RX: ACK,MODE,1 

$	13-Dec-2018	21:05:36.300	Ascend	Vel PID Values																		0.050000	0.010000	0.009834	0.050001	-56168701928297854000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1936851790630960600000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:36.300	Ascend	SBE41 Message						   19.75, 22.1502, 35.2081  	19.750000	19.544594	0.032709	0.010000	-0.015000	0.059229	1.000000																							

$	13-Dec-2018	21:05:36.954	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.750000	137.234308	29.750000	194.000000																																

$	13-Dec-2018	21:05:37.298	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000166	1628892355920637800000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-56168701928297854000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:37.298	Ascend	SBE41 Message						   19.74, 22.1504, 35.2071  	19.740000	19.580807	0.004727	0.010000	0.010000	0.058277	1.000000																							

$	13-Dec-2018	21:05:37.850	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.740000	137.232825	29.750000	194.000000																																

$	13-Dec-2018	21:05:38.301	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:05:38.297	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009967	-47237878321698495000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1628892355920637800000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:38.297	Ascend	SBE41 Message						   19.74, 22.1509, 35.2086  	19.740000	19.633462	-0.010882	0.000000	0.005000	0.056677	1.000000																							

$	13-Dec-2018	21:05:38.953	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.740000	137.255043	29.750000	194.000000																																

$	13-Dec-2018	21:05:39.296	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	1369898471329256400000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-47237878321698495000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:39.296	Ascend	SBE41 Message						   19.75, 22.1511, 35.2075  	19.750000	19.687539	-0.019504	-0.010000	-0.005000	0.054441	1.000000																							

$	13-Dec-2018	21:05:39.851	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.750000	137.321174	29.750000	194.000000																																

$	13-Dec-2018	21:05:40.302	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:05:40.295	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000033	-39727055668548438000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1369898471329256400000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:40.295	Ascend	SBE41 Message						   19.76, 22.1512, 35.2069  	19.760000	19.725389	-0.024502	-0.010000	-0.010000	0.051679	1.000000																							

$	13-Dec-2018	21:05:40.956	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.760000	137.303576	29.750000	194.000000																																

$	13-Dec-2018	21:05:41.303	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:05:41.294	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019934	1152084614387904700000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-39727055668548438000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:41.294	Ascend	SBE41 Message						   19.75, 22.1512, 35.1964  	19.750000	19.741746	-0.026878	0.010000	0.000000	0.048642	1.000000																							

$	13-Dec-2018	21:05:41.954	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.750000	137.509741	29.750000	194.000000																																

$	13-Dec-2018	21:05:42.293	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000066	-33410453817249236000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1152084614387904700000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:42.293	Ascend	SBE41 Message						   19.74, 22.1515, 35.2087  	19.740000	19.745129	-0.027513	0.010000	0.010000	0.045762	1.000000																							

$	13-Dec-2018	21:05:42.852	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.740000	137.514338	29.750000	194.000000																																

$	13-Dec-2018	21:05:43.292	Ascend	Vel PID Values																		0.050000	0.709999	0.707670	0.697670	968903160700227870000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-33410453817249236000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:43.292	Ascend	SBE41 Message						   19.03, 22.1519, 35.1956  	19.030001	19.746201	-0.027092	0.709999	0.360000	0.043526	1.000000																							

$	13-Dec-2018	21:05:43.852	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	19.030001	137.506053	29.750000	194.000000																																

$	13-Dec-2018	21:05:44.290	Ascend	Vel PID Values																		0.050000	0.650002	0.650197	-0.057472	-28098191660306606000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	968903160700227870000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:44.290	Ascend	SBE41 Message						   18.38, 22.1523, 35.2080  	18.379999	19.746533	-0.024979	0.650002	0.680000	0.042167	1.000000																							

$	13-Dec-2018	21:05:44.851	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.379999	137.533128	29.750000	194.000000																																

$	13-Dec-2018	21:05:45.291	Ascend	Vel PID Values																		0.050000	0.000000	0.002163	-0.648034	814847558148891500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-28098191660306606000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:45.291	Ascend	SBE41 Message						   18.38, 22.1526, 35.2086  	18.379999	19.726030	-0.017961	0.000000	0.325001	0.041554	1.000000																							

$	13-Dec-2018	21:05:45.852	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.379999	137.571551	29.750000	194.000000																																

$	13-Dec-2018	21:05:46.289	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009963	-0.012127	-23630579186317853000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	814847558148891500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:46.289	Ascend	SBE41 Message						   18.39, 22.1526, 35.2088  	18.389999	19.630000	0.000424	-0.010000	-0.005000	0.041544	1.000000																							

$	13-Dec-2018	21:05:46.854	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.389999	137.558103	29.750000	194.000000																																

$	13-Dec-2018	21:05:47.303	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:05:47.289	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009930	685286796403217830000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-23630579186317853000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:47.289	Ascend	SBE41 Message						   18.39, 22.1527, 35.2091  	18.389999	19.399346	0.035629	0.000000	-0.005000	0.042309	1.000000																							

$	13-Dec-2018	21:05:47.955	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.389999	137.646057	29.750000	194.000000																																

$	13-Dec-2018	21:05:48.288	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010000	-19873317095693318000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	685286796403217830000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:48.288	Ascend	SBE41 Message						   18.38, 22.1526, 35.2094  	18.379999	19.053569	0.083069	0.010000	0.005000	0.044114	1.000000																							

$	13-Dec-2018	21:05:48.852	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.379999	137.650788	29.750000	194.000000																																

$	13-Dec-2018	21:05:49.303	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:05:49.287	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019901	-0.029868	576326195775106230000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-19873317095693318000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:49.287	Ascend	SBE41 Message						   18.40, 22.1526, 35.2087  	18.400000	18.713707	0.127138	-0.020000	-0.005000	0.046846	1.000000																							

$	13-Dec-2018	21:05:50.183	Ascend	Error in I2CPortBase.Execute

$	13-Dec-2018	21:05:50.188	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.400000	137.650788	29.750000	194.000000																																

$	13-Dec-2018	21:05:50.398	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0960202

$	13-Dec-2018	21:05:50.704	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.400000	137.684122	29.750000	194.000000																																

$	13-Dec-2018	21:05:51.502	Ascend	MSC: RX: 0x3C47,A,02/01/2012 03:30:56,0,-1.00,-1.0000,-1.0000,252,163,1,66,22.41,54.77,11.576,5.254e-01,10680.00,2230.00,1167.43,15.63,-248774DBF53A45A4B613768336EB1743D78407A697AE979DE775373956F5F6B0D673C63EB61405F895ECE5EE75FF961B9645767B16BAB704D75847B76816C874B8CF991F5961F99029A989A6998839521905E8ABC84427DC5773B71046B3B663E61855D5159EE571A54AC52B351084FFA4F444EE14ED6,6737.4 

$	13-Dec-2018	21:05:51.514	Ascend	MSC: Data: 0x3C47,A,02/01/2012 03:30:56,0,-1.00,-1.0000,-1.0000,252,163,1,66,22.41,54.77,11.576,5.254e-01,10680.00,2230.00,1167.43,15.63,-248774DBF53A45A4B613768336EB1743D78407A697AE979DE775373956F5F6B0D673C63EB61405F895ECE5EE75FF961B9645767B16BAB704D75847B76816C874B8CF991F5961F99029A989A6998839521905E8ABC84427DC5773B71046B3B663E61855D5159EE571A54AC52B351084FFA4F444EE14ED6,6737.4 

$	13-Dec-2018	21:05:51.723	Ascend	MSC post: 6737.4

$	13-Dec-2018	21:05:50.553	Ascend	Vel PID Values																		0.050000	0.000000	-0.000066	0.019834	-16713459677478082000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	576326195775106230000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:50.553	Ascend	SBE41 Message						   18.40, 22.1533, 35.2092  	18.400000	18.495265	0.154604	0.000000	-0.010000	0.049968	1.000000																							

$	13-Dec-2018	21:05:51.285	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000066	484690330646864380000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-16713459677478082000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:51.285	Ascend	SBE41 Message						   18.40, 22.1533, 35.2092  	18.400000	18.407991	0.165563	0.000000	0.000000	0.052994	1.000000																							

$	13-Dec-2018	21:05:52.282	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	-14056019588759068000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	484690330646864380000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:52.282	Ascend	SBE41 Message						   18.40, 22.1525, 35.2077  	18.400000	18.389719	0.167877	0.000000	0.000000	0.055637	1.000000																							

$	13-Dec-2018	21:05:53.084	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.400000	137.786485	29.750000	194.000000																																

$	13-Dec-2018	21:05:53.206	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7055636

$	13-Dec-2018	21:05:53.310	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:05:53.314	Ascend	Starting pH sample

$	13-Dec-2018	21:05:53.513	Ascend	MSC: OUT: W

$	13-Dec-2018	21:05:53.769	Ascend	MSC: OUT: W

$	13-Dec-2018	21:05:53.310	Ascend	Vel PID Values																		0.050000	0.020000	0.019934	0.019934	407624568074012940000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-14056019588759068000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:53.310	Ascend	SBE41 Message						   18.38, 22.1531, 35.2093  	18.379999	18.390496	0.165230	0.020000	0.010000	0.057809	1.000000																							

$	13-Dec-2018	21:05:54.220	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:05:54.226	Ascend	MSC: Got ACK

$	13-Dec-2018	21:05:54.628	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.379999	138.328083	29.750000	194.000000																																

$	13-Dec-2018	21:05:54.739	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5276068

$	13-Dec-2018	21:05:54.843	Ascend	MSC: OUT: MODE,2

$	13-Dec-2018	21:05:54.947	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:05:54.951	Ascend	MSC: Got ACK

$	13-Dec-2018	21:05:54.442	Ascend	Vel PID Values																		0.050000	-0.090000	-0.089634	-0.109568	-11821112474146375000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	407624568074012940000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:54.442	Ascend	SBE41 Message						   18.47, 22.1530, 35.2092  	18.469999	18.394095	0.152875	-0.090000	-0.035000	0.059508	1.000000																							

$	13-Dec-2018	21:05:55.501	Ascend	MSC: RX: ACK,MODE,2 

$	13-Dec-2018	21:05:55.385	Ascend	Vel PID Values																		0.050000	-0.090000	-0.090000	-0.000365	342812261750244910000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-11821112474146375000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:55.385	Ascend	SBE41 Message						   18.56, 22.1536, 35.2088  	18.559999	18.397194	0.123935	-0.090000	-0.090000	0.060756	1.000000																							

$	13-Dec-2018	21:05:56.155	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.559999	138.345100	29.750000	194.000000																																

$	13-Dec-2018	21:05:56.267	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5217383

$	13-Dec-2018	21:05:56.371	Ascend	Vel PID Values																		0.050000	-0.020000	-0.020233	0.069766	-9941555590757101900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	342812261750244910000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:56.371	Ascend	SBE41 Message						   18.58, 22.1532, 35.2083  	18.580000	18.399714	0.080846	-0.020000	-0.055000	0.061539	1.000000																							

$	13-Dec-2018	21:05:56.922	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.580000	138.418339	29.750000	194.000000																																

$	13-Dec-2018	21:05:57.274	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:05:57.376	Ascend	Vel PID Values																		0.050000	0.000000	-0.000067	0.020166	288305112131955960000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-9941555590757101900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:57.376	Ascend	SBE41 Message						   18.58, 22.1543, 35.2070  	18.580000	18.408035	0.037789	0.000000	-0.010000	0.061830	1.000000																							

$	13-Dec-2018	21:05:57.929	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.580000	138.564944	29.750000	194.000000																																

$	13-Dec-2018	21:05:58.476	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.580000	138.565190	29.750000	194.000000																																

$	13-Dec-2018	21:05:59.273	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:05:58.278	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009900	-8360848251826723000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	288305112131955960000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:05:58.278	Ascend	SBE41 Message						   18.59, 22.1550, 35.2087  	18.590000	18.432644	0.007739	-0.010000	-0.005000	0.061605	1.000000																							

$	13-Dec-2018	21:05:59.278	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009934	242464599302974970000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-8360848251826723000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:05:59.278	Ascend	SBE41 Message						   18.59, 22.1546, 35.2090  	18.590000	18.475554	-0.008355	0.000000	-0.005000	0.060785	1.000000																							

$	13-Dec-2018	21:06:00.076	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:06:00.382	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.590000	138.596267	29.750000	194.000000																																

$	13-Dec-2018	21:06:00.494	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2206075

$	13-Dec-2018	21:06:00.275	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	-7031473379786273700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	242464599302974970000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:00.275	Ascend	SBE41 Message						   18.59, 22.1545, 35.2073  	18.590000	18.523309	-0.016520	0.000000	0.000000	0.059363	1.000000																							

$	13-Dec-2018	21:06:01.148	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.590000	139.092721	29.750000	194.000000																																

$	13-Dec-2018	21:06:01.274	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	203912728013801930000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-7031473379786273700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:01.274	Ascend	SBE41 Message						   18.59, 22.1545, 35.2096  	18.590000	18.559008	-0.020843	0.000000	0.000000	0.057395	1.000000																							

$	13-Dec-2018	21:06:02.050	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.590000	139.218949	29.750000	194.000000																																

$	13-Dec-2018	21:06:02.273	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009967	-5913469112400255900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	203912728013801930000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:02.273	Ascend	SBE41 Message						   18.60, 22.1559, 35.2089  	18.600000	18.577768	-0.022722	-0.010000	-0.005000	0.054949	1.000000																							

$	13-Dec-2018	21:06:03.053	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.600000	139.215350	29.750000	194.000000																																

$	13-Dec-2018	21:06:03.272	Ascend	Vel PID Values																		0.050000	0.020000	0.019901	0.029868	171490604259607420000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-5913469112400255900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:03.272	Ascend	SBE41 Message						   18.58, 22.1552, 35.2093  	18.580000	18.585539	-0.023303	0.020000	0.005000	0.052076	1.000000																							

$	13-Dec-2018	21:06:04.055	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.580000	139.316186	29.750000	194.000000																																

$	13-Dec-2018	21:06:04.272	Ascend	Vel PID Values																		0.050000	0.250000	0.249234	0.229334	-4973227523528615100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	171490604259607420000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:04.272	Ascend	SBE41 Message						   18.33, 22.1555, 35.2088  	18.330000	18.588806	-0.023395	0.250000	0.135000	0.048869	1.000000																							

$	13-Dec-2018	21:06:05.052	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	18.330000	139.333904	29.750000	194.000000																																

$	13-Dec-2018	21:06:05.270	Ascend	Vel PID Values																		0.050000	0.860001	0.857969	0.608735	144223598182329830000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-4973227523528615100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:05.270	Ascend	SBE41 Message						   17.47, 22.1551, 35.2096  	17.469999	18.589692	-0.022472	0.860001	0.555000	0.045613	1.000000																							

$	13-Dec-2018	21:06:06.050	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17  Pres, BP, BatV, BatI: 	17.469999	139.371969	29.750000	194.000000																																

$	13-Dec-2018	21:06:06.511	Ascend	ERROR: Missed PH message 5

$	13-Dec-2018	21:06:06.615	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:06:06.619	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:06:07.221	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:06:07.237	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:06:07.340	Ascend	Sending FLBB run command

$	13-Dec-2018	21:06:07.442	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:06:07.546	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:06:07.746	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:06:07.863	Ascend	CTD post: 17.32	22.156	35.21

$	13-Dec-2018	21:06:06.269	Ascend	Vel PID Values																		0.050000	0.150000	0.152359	-0.705610	-4182484347287565000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	144223598182329830000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:06.269	Ascend	SBE41 Message						   17.32, 22.1555, 35.2097  	17.320000	18.580470	-0.018284	0.150000	0.505000	0.042850	1.000000																							

$	13-Dec-2018	21:06:07.336	Ascend	Vel PID Values																		0.050000	0.000000	0.000503	-0.151856	121292046071339380000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-4182484347287565000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:07.336	Ascend	SBE41 Message						   17.32, 22.1556, 35.2095  	17.320000	18.527444	-0.006420	0.000000	0.075000	0.041148	1.000000																							

$	13-Dec-2018	21:06:08.555	Ascend	Radiometer Message																																	SATFI40287,-0.0051,0.0017,-0.0087,-0.2296 			

$	13-Dec-2018	21:06:08.770	Ascend	Radiometer post: SATFI40287,-0.0051,0.0017,-0.0087,-0.2296 

$	13-Dec-2018	21:06:08.303	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019933	-0.020436	-3517469336068842000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	121292046071339380000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:08.303	Ascend	SBE41 Message						   17.34, 22.1561, 35.2100  	17.340000	18.372384	0.018657	-0.020000	-0.010000	0.040897	1.000000																							

$	13-Dec-2018	21:06:08.321	Ascend	Optode Message																												4330,1532,265.788,22.425,29.139,29.070,36.118,7.048,531.1,464.3,112.8  								

$	13-Dec-2018	21:06:09.342	Ascend	Optode post: 4330,1532,265.788,22.425,29.139,29.070,36.118,7.048,531.1,464.3,112.8  

$	13-Dec-2018	21:06:08.323	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:06:09.761	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.340000	139.365569	29.750000	194.000000																																

$	13-Dec-2018	21:06:09.872	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.3730739

$	13-Dec-2018	21:06:09.976	Ascend	FLBB Message																											/99/99,99:99:99,695,2315,700,4130,533  									

$	13-Dec-2018	21:06:10.086	Ascend	FLBB post: /99/99,99:99:99,695,2315,700,4130,533  

$	13-Dec-2018	21:06:09.340	Ascend	Vel PID Values																		0.050000	0.020000	0.019867	0.039801	102006610745996410000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-3517469336068842000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:09.340	Ascend	SBE41 Message						   17.32, 22.1565, 35.2095  	17.320000	18.092238	0.057712	0.020000	0.000000	0.042109	1.000000																							

$	13-Dec-2018	21:06:10.744	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.320000	140.240543	29.750000	194.000000																																

$	13-Dec-2018	21:06:10.266	Ascend	Vel PID Values																		0.050000	0.000000	0.000066	-0.019801	-2958191711633895800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	102006610745996410000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:10.266	Ascend	SBE41 Message						   17.32, 22.1562, 35.2094  	17.320000	17.761233	0.100973	0.000000	0.010000	0.044557	1.000000																							

$	13-Dec-2018	21:06:11.131	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:06:11.332	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000066	85787559637382982000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-2958191711633895800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:11.332	Ascend	SBE41 Message						   17.32, 22.1569, 35.2097  	17.320000	17.502754	0.133925	0.000000	0.000000	0.047670	1.000000																							

$	13-Dec-2018	21:06:11.885	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.320000	140.247948	29.750000	194.000000																																

$	13-Dec-2018	21:06:11.996	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1176687

$	13-Dec-2018	21:06:12.301	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.320000	140.237018	29.750000	194.000000																																

$	13-Dec-2018	21:06:13.002	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:06:12.262	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019934	-0.019934	-2487839229484106500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	85787559637382982000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:12.262	Ascend	SBE41 Message						   17.34, 22.1570, 35.2091  	17.340000	17.372679	0.150448	-0.020000	-0.010000	0.050897	1.000000																							

$	13-Dec-2018	21:06:13.340	Ascend	Vel PID Values																		0.050000	0.020000	0.019867	0.039801	72147337655039089000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-2487839229484106500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:13.340	Ascend	SBE41 Message						   17.32, 22.1578, 35.2086  	17.320000	17.332887	0.155500	0.020000	0.000000	0.053868	1.000000																							

$	13-Dec-2018	21:06:13.804	Ascend	MSC: RX: 0x6051,pH,02/01/2012 03:31:21,0,-1.00,-1.0000,-1.0000,277,163,0,22.42,54.77,11.744,4.640e-02,7.1234,0.000,-1.011946,0.000938,-1.

$	13-Dec-2018	21:06:13.909	Ascend	MSC: Data: 0x6051,pH,02/01/2012 03:31:21,0,-1.00,-1.0000,-1.0000,277,163,0,22.42,54.77,11.744,4.640e-02,7.1234,0.000,-1.011946,0.000938,-1.

$	13-Dec-2018	21:06:14.013	Ascend	MSC post: 7.1234

$	13-Dec-2018	21:06:14.318	Ascend	PTH Message														780.081299	23.791667	51.941437	24.557700																			

$	13-Dec-2018	21:06:14.520	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.320000	140.269011	29.175000	283.500000																																

$	13-Dec-2018	21:06:14.633	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6310936

$	13-Dec-2018	21:06:14.638	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:06:14.837	Ascend	MSC: OUT: SLP

$	13-Dec-2018	21:06:14.261	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009901	-0.029768	-2092272791996133500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	72147337655039089000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:14.261	Ascend	SBE41 Message						   17.33, 22.1569, 35.2099  	17.330000	17.325458	0.155275	-0.010000	0.005000	0.056467	1.000000																							

$	13-Dec-2018	21:06:15.493	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	140.876606	29.175000	283.500000																																

$	13-Dec-2018	21:06:15.639	Ascend	MSC: RX: ACK,SLP 

$	13-Dec-2018	21:06:15.310	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009868	60675910967887870000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-2092272791996133500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:15.310	Ascend	SBE41 Message						   17.33, 22.1573, 35.2093  	17.330000	17.324311	0.148834	0.000000	-0.005000	0.058611	1.000000																							

$	13-Dec-2018	21:06:16.292	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.147092	29.175000	283.500000																																

$	13-Dec-2018	21:06:16.258	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	-1759601418068748300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	60675910967887870000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:16.258	Ascend	SBE41 Message						   17.33, 22.1575, 35.2053  	17.330000	17.325311	0.129502	0.000000	0.000000	0.060307	1.000000																							

$	13-Dec-2018	21:06:17.191	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.152665	29.175000	283.500000																																

$	13-Dec-2018	21:06:17.302	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	51028441123993708000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-1759601418068748300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:17.302	Ascend	SBE41 Message						   17.33, 22.1574, 35.2094  	17.330000	17.327043	0.094621	0.000000	0.000000	0.061434	1.000000																							

$	13-Dec-2018	21:06:18.191	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.152509	29.175000	283.500000																																

$	13-Dec-2018	21:06:18.303	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	0.000000	-1479824792595817500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	51028441123993708000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:18.303	Ascend	SBE41 Message						   17.33, 22.1575, 35.2086  	17.330000	17.328036	0.053559	0.000000	0.000000	0.061930	1.000000																							

$	13-Dec-2018	21:06:19.231	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.165756	29.175000	283.500000																																

$	13-Dec-2018	21:06:19.341	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000000	42914918985278707000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-1479824792595817500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:19.341	Ascend	SBE41 Message						   17.33, 22.1576, 35.2090  	17.330000	17.328540	0.021537	0.000000	0.000000	0.061775	1.000000																							

$	13-Dec-2018	21:06:20.193	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.241297	29.175000	283.500000																																

$	13-Dec-2018	21:06:20.304	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009967	-1244532650573082500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	42914918985278707000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:20.304	Ascend	SBE41 Message						   17.34, 22.1583, 35.2097  	17.340000	17.329182	0.005376	-0.010000	-0.005000	0.061038	1.000000																							

$	13-Dec-2018	21:06:21.191	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.340000	141.217738	29.175000	283.500000																																

$	13-Dec-2018	21:06:21.303	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009934	36091446866619395000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-1244532650573082500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:21.303	Ascend	SBE41 Message						   17.34, 22.1578, 35.2103  	17.340000	17.329777	0.000384	0.000000	-0.005000	0.059786	1.000000																							

$	13-Dec-2018	21:06:22.190	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.340000	141.334310	29.175000	283.500000																																

$	13-Dec-2018	21:06:22.301	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010000	-1046651959131962400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	36091446866619395000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:22.301	Ascend	SBE41 Message						   17.33, 22.1583, 35.2097  	17.330000	17.330282	-0.000597	0.010000	0.005000	0.058065	1.000000																							

$	13-Dec-2018	21:06:23.193	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.315654	29.175000	283.500000																																

$	13-Dec-2018	21:06:23.304	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	30352906814826911000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-1046651959131962400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:23.304	Ascend	SBE41 Message						   17.33, 22.1577, 35.2104  	17.330000	17.331351	-0.000871	0.000000	0.005000	0.055883	1.000000																							

$	13-Dec-2018	21:06:24.190	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.371451	29.175000	283.500000																																

$	13-Dec-2018	21:06:24.301	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000033	-880234297629980580000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	30352906814826911000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:24.301	Ascend	SBE41 Message						   17.33, 22.1575, 35.2104  	17.330000	17.333288	-0.000986	0.000000	0.000000	0.053237	1.000000																							

$	13-Dec-2018	21:06:25.190	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.376868	29.175000	283.500000																																

$	13-Dec-2018	21:06:25.301	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000000	25526794631269436000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-880234297629980580000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:25.301	Ascend	SBE41 Message						   17.33, 22.1579, 35.2102  	17.330000	17.335020	-0.000986	0.000000	0.000000	0.050210	1.000000																							

$	13-Dec-2018	21:06:26.191	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.418651	29.175000	283.500000																																

$	13-Dec-2018	21:06:26.301	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	-0.000000	-740277044306813580000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	25526794631269436000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:26.301	Ascend	SBE41 Message						   17.33, 22.1574, 35.2095  	17.330000	17.335020	-0.000864	0.000000	0.000000	0.047103	1.000000																							

$	13-Dec-2018	21:06:27.189	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.433880	29.175000	283.500000																																

$	13-Dec-2018	21:06:27.302	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	21468034284897593000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-740277044306813580000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:27.302	Ascend	SBE41 Message						   17.33, 22.1571, 35.2096  	17.330000	17.333288	-0.000588	0.000000	0.000000	0.044458	1.000000																							

$	13-Dec-2018	21:06:28.189	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	17.330000	141.490899	29.175000	283.500000																																

$	13-Dec-2018	21:06:28.300	Ascend	Vel PID Values																		0.050000	0.440001	0.438536	0.438536	-622572994262030230000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	21468034284897593000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:28.300	Ascend	SBE41 Message						   16.89, 22.1583, 35.2086  	16.889999	17.331345	-0.000268	0.440001	0.220000	0.042767	1.000000																							

$	13-Dec-2018	21:06:29.191	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.889999	141.485602	29.175000	283.500000																																

$	13-Dec-2018	21:06:29.302	Ascend	Vel PID Values																		0.050000	0.719999	0.719065	0.280529	18054616833598876000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-622572994262030230000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:29.302	Ascend	SBE41 Message						   16.17, 22.1586, 35.2107  	16.170000	17.328996	0.000096	0.719999	0.580000	0.042071	1.000000																							

$	13-Dec-2018	21:06:30.194	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.170000	141.581528	29.175000	283.500000																																

$	13-Dec-2018	21:06:30.306	Ascend	Vel PID Values																		0.050000	0.049999	0.052227	-0.666838	-523583888174367480000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	18054616833598876000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:30.306	Ascend	SBE41 Message						   16.12, 22.1588, 35.2088  	16.120001	17.314191	0.001989	0.049999	0.384999	0.041958	1.000000																							

$	13-Dec-2018	21:06:31.189	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	141.571343	29.175000	283.500000																																

$	13-Dec-2018	21:06:31.299	Ascend	Vel PID Values																		0.050000	0.020000	0.020104	-0.032123	15183932757056657000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-523583888174367480000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:31.299	Ascend	SBE41 Message						   16.10, 22.1585, 35.2102  	16.100000	17.246656	0.010470	0.020000	0.035000	0.042259	1.000000																							

$	13-Dec-2018	21:06:32.191	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.100000	141.605020	29.175000	283.500000																																

$	13-Dec-2018	21:06:32.302	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009900	-0.030004	-440334049954643070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	15183932757056657000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:32.302	Ascend	SBE41 Message						   16.11, 22.1586, 35.2086  	16.110001	17.070572	0.032480	-0.010000	0.005000	0.043059	1.000000																							

$	13-Dec-2018	21:06:33.189	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.110001	141.623206	29.175000	283.500000																																

$	13-Dec-2018	21:06:33.301	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019834	12769687448684648000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-440334049954643070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:33.301	Ascend	SBE41 Message						   16.10, 22.1594, 35.2102  	16.100000	16.781722	0.068413	0.010000	0.000000	0.044660	1.000000																							

$	13-Dec-2018	21:06:34.189	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.100000	141.705081	29.175000	283.500000																																

$	13-Dec-2018	21:06:34.301	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019868	-370320936011854790000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	12769687448684648000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:34.301	Ascend	SBE41 Message						   16.11, 22.1597, 35.2099  	16.110001	16.469441	0.107042	-0.010000	0.000000	0.047057	1.000000																							

$	13-Dec-2018	21:06:35.189	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.110001	141.693354	29.175000	283.500000																																

$	13-Dec-2018	21:06:35.300	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019868	10739307144343789000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-370320936011854790000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:35.300	Ascend	SBE41 Message						   16.10, 22.1589, 35.2107  	16.100000	16.245046	0.134605	0.010000	0.000000	0.049912	1.000000																							

$	13-Dec-2018	21:06:36.190	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.100000	141.746722	29.175000	283.500000																																

$	13-Dec-2018	21:06:36.301	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019901	-0.029835	-311439907185969850000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	10739307144343789000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:36.301	Ascend	SBE41 Message						   16.12, 22.1595, 35.2102  	16.120001	16.140333	0.147345	-0.020000	-0.005000	0.052736	1.000000																							

$	13-Dec-2018	21:06:37.188	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	141.747139	29.175000	283.500000																																

$	13-Dec-2018	21:06:37.300	Ascend	Vel PID Values																		0.050000	0.000000	-0.000066	0.019834	9031757308393125000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-311439907185969850000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:37.300	Ascend	SBE41 Message						   16.12, 22.1591, 35.2107  	16.120001	16.110392	0.150774	0.000000	-0.010000	0.055211	1.000000																							

$	13-Dec-2018	21:06:38.189	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	141.825713	29.175000	283.500000																																

$	13-Dec-2018	21:06:38.300	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000066	-261920961943400590000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	9031757308393125000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:38.300	Ascend	SBE41 Message						   16.12, 22.1594, 35.2109  	16.120001	16.105842	0.149498	0.000000	0.000000	0.057200	1.000000																							

$	13-Dec-2018	21:06:39.192	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	141.830377	29.175000	283.500000																																

$	13-Dec-2018	21:06:39.303	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009967	7595707896358616700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-261920961943400590000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:39.303	Ascend	SBE41 Message						   16.11, 22.1599, 35.2101  	16.110001	16.106694	0.141014	0.010000	0.005000	0.058586	1.000000																							

$	13-Dec-2018	21:06:40.195	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.110001	141.897500	29.175000	283.500000																																

$	13-Dec-2018	21:06:40.306	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	-220275528994399880000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	7595707896358616700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:40.306	Ascend	SBE41 Message						   16.11, 22.1603, 35.2098  	16.110001	16.109670	0.118840	0.000000	0.005000	0.059333	1.000000																							

$	13-Dec-2018	21:06:41.188	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.110001	141.899526	29.175000	283.500000																																

$	13-Dec-2018	21:06:41.300	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	6387990340837596400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-220275528994399880000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:41.300	Ascend	SBE41 Message						   16.12, 22.1608, 35.2100  	16.120001	16.113590	0.082616	-0.010000	-0.005000	0.059478	1.000000																							

$	13-Dec-2018	21:06:42.189	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	141.980760	29.175000	283.500000																																

$	13-Dec-2018	21:06:42.301	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009934	-185251719884290300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	6387990340837596400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:42.301	Ascend	SBE41 Message						   16.12, 22.1606, 35.2103  	16.120001	16.116169	0.043676	0.000000	-0.005000	0.059082	1.000000																							

$	13-Dec-2018	21:06:43.189	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	141.988963	29.175000	283.500000																																

$	13-Dec-2018	21:06:43.300	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	5372299876644418200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-185251719884290300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:43.300	Ascend	SBE41 Message						   16.12, 22.1608, 35.2101  	16.120001	16.116120	0.015937	0.000000	0.000000	0.058196	1.000000																							

$	13-Dec-2018	21:06:44.190	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	142.011814	29.175000	283.500000																																

$	13-Dec-2018	21:06:44.301	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	-155796696422688140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	5372299876644418200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:44.301	Ascend	SBE41 Message						   16.12, 22.1604, 35.2109  	16.120001	16.114922	0.003140	0.000000	0.000000	0.056837	1.000000																							

$	13-Dec-2018	21:06:45.190	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	142.020069	29.175000	283.500000																																

$	13-Dec-2018	21:06:45.301	Ascend	Vel PID Values																		0.050000	-0.009998	-0.009965	-0.009965	4518104196257956500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-155796696422688140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:45.301	Ascend	SBE41 Message						   16.13, 22.1609, 35.2095  	16.129999	16.114981	-0.000569	-0.009998	-0.004999	0.055010	1.000000																							

$	13-Dec-2018	21:06:46.187	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.129999	142.095760	29.175000	283.500000																																

$	13-Dec-2018	21:06:46.301	Ascend	Vel PID Values																		0.050000	0.009998	0.009932	0.019897	-131025021691480730000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	4518104196257956500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:46.301	Ascend	SBE41 Message						   16.12, 22.1604, 35.2106  	16.120001	16.116742	-0.001348	0.009998	0.000000	0.052748	1.000000																							

$	13-Dec-2018	21:06:47.188	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	142.096885	29.175000	283.500000																																

$	13-Dec-2018	21:06:47.301	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000068	3799725629052941000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-131025021691480730000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:47.301	Ascend	SBE41 Message						   16.11, 22.1606, 35.2100  	16.110001	16.118931	-0.001513	0.010000	0.009999	0.050211	1.000000																							

$	13-Dec-2018	21:06:48.188	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.110001	142.155893	29.175000	283.500000																																

$	13-Dec-2018	21:06:48.299	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019934	-110192043242535280000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	3799725629052941000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:48.299	Ascend	SBE41 Message						   16.12, 22.1606, 35.2106  	16.120001	16.120730	-0.001367	-0.010000	0.000000	0.047816	1.000000																							

$	13-Dec-2018	21:06:49.188	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	142.149732	29.175000	283.500000																																

$	13-Dec-2018	21:06:49.299	Ascend	Vel PID Values																		0.050000	0.020000	0.019901	0.029834	3195569254033523100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-110192043242535280000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:49.299	Ascend	SBE41 Message						   16.10, 22.1615, 35.2100  	16.100000	16.121907	-0.001028	0.020000	0.005000	0.046068	1.000000																							

$	13-Dec-2018	21:06:50.190	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.100000	142.212830	29.175000	283.500000																																

$	13-Dec-2018	21:06:50.300	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019868	-0.039768	-92671508366972168000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	3195569254033523100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:50.300	Ascend	SBE41 Message						   16.12, 22.1613, 35.2096  	16.120001	16.121673	-0.000681	-0.020000	0.000000	0.045234	1.000000																							

$	13-Dec-2018	21:06:51.186	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	142.220162	29.175000	283.500000																																

$	13-Dec-2018	21:06:51.298	Ascend	Vel PID Values																		0.050000	0.000000	-0.000066	0.019801	2687473742642192900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-92671508366972168000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:51.298	Ascend	SBE41 Message						   16.12, 22.1617, 35.2105  	16.120001	16.119437	-0.000411	0.000000	-0.010000	0.045083	1.000000																							

$	13-Dec-2018	21:06:52.189	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	16.120001	142.327420	29.175000	283.500000																																

$	13-Dec-2018	21:06:52.302	Ascend	Vel PID Values																		0.050000	0.210001	0.209302	0.209368	-77936738536623586000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	2687473742642192900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:52.302	Ascend	SBE41 Message						   15.91, 22.1616, 35.2104  	15.910000	16.116126	-0.000149	0.210001	0.105000	0.045199	1.000000																							

$	13-Dec-2018	21:06:53.188	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18  Pres, BP, BatV, BatI: 	15.910000	142.311610	29.175000	283.500000																																

$	13-Dec-2018	21:06:53.642	Ascend	ERROR: Missed NO3 message 5

$	13-Dec-2018	21:06:53.747	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:06:53.751	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:06:54.450	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:06:54.467	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:06:54.569	Ascend	Sending FLBB run command

$	13-Dec-2018	21:06:54.670	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:06:54.775	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:06:54.877	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:06:55.091	Ascend	CTD post: 15.06	22.162	35.21

$	13-Dec-2018	21:06:53.299	Ascend	Vel PID Values																		0.050000	0.849999	0.847868	0.638566	2260165417562083900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-77936738536623586000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:53.299	Ascend	SBE41 Message						   15.06, 22.1620, 35.2105  	15.060000	16.112992	0.000246	0.849999	0.530000	0.045227	1.000000																							

$	13-Dec-2018	21:06:54.220	Ascend	Vel PID Values																		0.050000	0.210000	0.212126	-0.635742	-65544797109300430000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	2260165417562083900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:54.220	Ascend	SBE41 Message						   14.85, 22.1617, 35.2104  	14.850000	16.104294	0.001539	0.210000	0.530000	0.045121	1.000000																							

$	13-Dec-2018	21:06:55.791	Ascend	Radiometer Message																																	SATFI40287,-0.0049,0.0014,-0.0080,-0.2243 			

$	13-Dec-2018	21:06:56.005	Ascend	Radiometer post: SATFI40287,-0.0049,0.0014,-0.0080,-0.2243 

$	13-Dec-2018	21:06:55.236	Ascend	Vel PID Values																		0.050000	0.000000	0.000702	-0.211424	1900799116169712300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-65544797109300430000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:55.236	Ascend	SBE41 Message						   14.85, 22.1610, 35.2113  	14.850000	16.059183	0.007387	0.000000	0.105000	0.044941	1.000000																							

$	13-Dec-2018	21:06:55.550	Ascend	Optode Message																												4330,1532,265.747,22.426,29.140,29.071,36.118,7.048,531.1,464.0,112.7  								

$	13-Dec-2018	21:06:56.576	Ascend	Optode post: 4330,1532,265.747,22.426,29.140,29.071,36.118,7.048,531.1,464.0,112.7  

$	13-Dec-2018	21:06:55.552	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:06:56.993	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.850000	142.378993	29.175000	283.500000																																

$	13-Dec-2018	21:06:57.106	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.4721708

$	13-Dec-2018	21:06:57.111	Ascend	Starting ISUS sample

$	13-Dec-2018	21:06:57.313	Ascend	Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00

$	13-Dec-2018	21:06:57.319	Ascend	MSC: OUT: W

$	13-Dec-2018	21:06:57.768	Ascend	MSC: OUT: W

$	13-Dec-2018	21:06:57.871	Ascend	FLBB Message																											/99/99,99:99:99,695,2306,700,4130,533  									

$	13-Dec-2018	21:06:57.983	Ascend	FLBB post: /99/99,99:99:99,695,2306,700,4130,533  

$	13-Dec-2018	21:06:56.219	Ascend	Vel PID Values																		0.050000	-0.009999	-0.009965	-0.010667	-55123174368921664000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1900799116169712300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:56.219	Ascend	SBE41 Message						   14.86, 22.1611, 35.2112  	14.860000	15.918307	0.025025	-0.009999	-0.005000	0.045047	1.000000																							

$	13-Dec-2018	21:06:57.311	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009932	1598572056698728000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-55123174368921664000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:57.311	Ascend	SBE41 Message						   14.86, 22.1617, 35.2113  	14.860000	15.650110	0.058333	0.000000	-0.005000	0.045838	1.000000																							

$	13-Dec-2018	21:06:58.789	Ascend	MSC: RX: 

$	13-Dec-2018	21:06:58.794	Ascend	MSC: RX: 

$	13-Dec-2018	21:06:59.195	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.860000	142.205529	29.175000	283.500000																																

$	13-Dec-2018	21:06:59.307	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1959268

$	13-Dec-2018	21:06:59.411	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:06:59.415	Ascend	MSC: Got ACK

$	13-Dec-2018	21:06:58.222	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	-46358589644263113000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1598572056698728000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:06:58.222	Ascend	SBE41 Message						   14.86, 22.1611, 35.2117  	14.860000	15.319610	0.099182	0.000000	0.000000	0.047532	1.000000																							

$	13-Dec-2018	21:06:59.305	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009967	1344399099683630500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-46358589644263113000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:06:59.305	Ascend	SBE41 Message						   14.87, 22.1617, 35.2109  	14.870000	15.050906	0.132159	-0.010000	-0.005000	0.049814	1.000000																							

$	13-Dec-2018	21:07:00.524	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.870000	142.528802	29.175000	283.500000																																

$	13-Dec-2018	21:07:00.635	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3220953

$	13-Dec-2018	21:07:00.321	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009934	-38987573890825288000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1344399099683630500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:00.321	Ascend	SBE41 Message						   14.87, 22.1616, 35.2105  	14.870000	14.909729	0.149241	0.000000	-0.005000	0.052188	1.000000																							

$	13-Dec-2018	21:07:01.295	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.870000	142.780907	29.175000	283.500000																																

$	13-Dec-2018	21:07:01.643	Ascend	MSC: OUT: CTD,0,0.0000,0.0000,0.0000

$	13-Dec-2018	21:07:01.213	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010000	1130639642833933300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-38987573890825288000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:01.213	Ascend	SBE41 Message						   14.86, 22.1623, 35.2102  	14.860000	14.865775	0.154313	0.010000	0.005000	0.054278	1.000000																							

$	13-Dec-2018	21:07:02.310	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.860000	142.906003	29.175000	283.500000																																

$	13-Dec-2018	21:07:02.643	Ascend	MSC: RX: NAK,CTD,EConvertErr: 0 

$	13-Dec-2018	21:07:02.745	Ascend	MSC: EConvertErr: 0

$	13-Dec-2018	21:07:02.214	Ascend	Vel PID Values																		0.050000	0.030000	0.029933	0.019966	-32788549642184065000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	1130639642833933300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:02.214	Ascend	SBE41 Message						   14.83, 22.1624, 35.2108  	14.830000	14.860606	0.153876	0.030000	0.020000	0.055925	1.000000																							

$	13-Dec-2018	21:07:03.403	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.830000	142.896689	29.175000	283.500000																																

$	13-Dec-2018	21:07:03.210	Ascend	Vel PID Values																		0.050000	0.090000	0.089800	0.059867	950867939623337850000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-32788549642184065000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:03.210	Ascend	SBE41 Message						   14.74, 22.1617, 35.2114  	14.740000	14.862889	0.147992	0.090000	0.060000	0.057096	1.000000																							

$	13-Dec-2018	21:07:04.200	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.740000	142.966852	29.175000	283.500000																																

$	13-Dec-2018	21:07:04.643	Ascend	MSC: OUT: W

$	13-Dec-2018	21:07:04.898	Ascend	MSC: OUT: W

$	13-Dec-2018	21:07:04.311	Ascend	Vel PID Values																		0.050000	-0.120000	-0.119301	-0.209102	-27575170249076797000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	950867939623337850000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:04.311	Ascend	SBE41 Message						   14.86, 22.1629, 35.2054  	14.860000	14.863790	0.130425	-0.120000	-0.015000	0.057775	1.000000																							

$	13-Dec-2018	21:07:05.355	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:07:05.359	Ascend	MSC: Got ACK

$	13-Dec-2018	21:07:05.240	Ascend	Vel PID Values																		0.050000	-0.400001	-0.399068	-0.279766	799679937223227010000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-27575170249076797000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:05.240	Ascend	SBE41 Message						   15.26, 22.1628, 35.2109  	15.260000	14.858435	0.097896	-0.400001	-0.260000	0.058016	1.000000																							

$	13-Dec-2018	21:07:05.912	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:07:05.916	Ascend	MSC: Got ACK

$	13-Dec-2018	21:07:06.318	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.260000	142.940588	29.175000	283.500000																																

$	13-Dec-2018	21:07:06.429	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7873558

$	13-Dec-2018	21:07:06.534	Ascend	MSC: OUT: MODE,1

$	13-Dec-2018	21:07:06.209	Ascend	Vel PID Values																		0.050000	-0.030000	-0.031229	0.367838	-23190718179473587000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	799679937223227010000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:06.209	Ascend	SBE41 Message						   15.29, 22.1628, 35.2081  	15.290000	14.844983	0.058681	-0.030000	-0.215000	0.057846	1.000000																							

$	13-Dec-2018	21:07:07.193	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.290000	143.379644	29.175000	283.500000																																

$	13-Dec-2018	21:07:07.437	Ascend	MSC: RX: ACK,MODE,1 

$	13-Dec-2018	21:07:07.306	Ascend	Vel PID Values																		0.050000	0.020000	0.019831	0.051061	672530827204733970000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-23190718179473587000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:07.306	Ascend	SBE41 Message						   15.27, 22.1621, 35.2115  	15.270000	14.838876	0.026212	0.020000	-0.005000	0.057216	1.000000																							

$	13-Dec-2018	21:07:08.094	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.270000	143.541433	29.175000	283.500000																																

$	13-Dec-2018	21:07:08.208	Ascend	Vel PID Values																		0.050000	0.000000	0.000066	-0.019765	-19503393988937286000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	672530827204733970000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:08.208	Ascend	SBE41 Message						   15.27, 22.1621, 35.2112  	15.270000	14.876161	0.004152	0.000000	0.010000	0.056010	1.000000																							

$	13-Dec-2018	21:07:08.991	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.270000	143.563569	29.175000	283.500000																																

$	13-Dec-2018	21:07:09.436	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:07:09.206	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000066	565598425679181320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-19503393988937286000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:09.206	Ascend	SBE41 Message						   15.27, 22.1622, 35.2116  	15.270000	14.977694	-0.013833	0.000000	0.000000	0.053977	1.000000																							

$	13-Dec-2018	21:07:10.093	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.270000	143.558435	29.175000	283.500000																																

$	13-Dec-2018	21:07:10.206	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000000	-16402354344696259000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	565598425679181320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:10.206	Ascend	SBE41 Message						   15.27, 22.1627, 35.2113  	15.270000	15.110383	-0.030881	0.000000	0.000000	0.051071	1.000000																							

$	13-Dec-2018	21:07:10.992	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.270000	143.571272	29.175000	283.500000																																

$	13-Dec-2018	21:07:11.437	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:07:11.203	Ascend	Vel PID Values																		0.050000	0.020000	0.019934	0.019934	475668275996191480000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-16402354344696259000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:11.203	Ascend	SBE41 Message						   15.25, 22.1633, 35.2088  	15.250000	15.213286	-0.043334	0.020000	0.010000	0.047632	1.000000																							

$	13-Dec-2018	21:07:11.892	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:07:12.196	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	15.250000	143.589288	29.175000	283.500000																																

$	13-Dec-2018	21:07:12.312	Ascend	Vel PID Values																		0.050000	0.910000	0.907038	0.887104	-13794380003889553000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	475668275996191480000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:12.312	Ascend	SBE41 Message						   14.34, 22.1631, 35.2120  	14.340000	15.260170	-0.049036	0.910000	0.465000	0.044290	1.000000																							

$	13-Dec-2018	21:07:12.991	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	14.340000	143.598408	29.175000	283.500000																																

$	13-Dec-2018	21:07:13.201	Ascend	Vel PID Values																		0.050000	0.500000	0.501359	-0.405679	400037020112797050000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-13794380003889553000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:13.201	Ascend	SBE41 Message						   13.84, 22.1636, 35.2106  	13.840000	15.267312	-0.050594	0.500000	0.705000	0.041723	1.000000																							

$	13-Dec-2018	21:07:13.992	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19  Pres, BP, BatV, BatI: 	13.840000	143.596478	29.175000	283.500000																																

$	13-Dec-2018	21:07:14.446	Ascend	ERROR: Missed PH message 6

$	13-Dec-2018	21:07:14.450	Ascend	ERROR: Missed NO3 message 6

$	13-Dec-2018	21:07:14.651	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:07:14.655	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:07:15.257	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:07:15.274	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:07:15.376	Ascend	Sending FLBB run command

$	13-Dec-2018	21:07:15.477	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:07:15.584	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:07:15.783	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:07:15.898	Ascend	CTD post: 13.86	22.164	35.21

$	13-Dec-2018	21:07:14.201	Ascend	Vel PID Values																		0.050000	-0.020000	-0.018267	-0.519626	-11601073583271115000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	400037020112797050000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:14.201	Ascend	SBE41 Message						   13.86, 22.1636, 35.2117  	13.860000	15.237942	-0.048628	-0.020000	0.240000	0.040181	1.000000																							

$	13-Dec-2018	21:07:15.200	Ascend	Vel PID Values																		0.050000	0.009999	0.009902	0.028169	336431133914862330000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-11601073583271115000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:15.200	Ascend	SBE41 Message						   13.85, 22.1636, 35.2118  	13.850000	15.121661	-0.034998	0.009999	-0.005000	0.039699	1.000000																							

$	13-Dec-2018	21:07:16.599	Ascend	Radiometer Message																																	SATFI40287,-0.0045,0.0021,-0.0083,-0.2216 			

$	13-Dec-2018	21:07:16.839	Ascend	Radiometer post: SATFI40287,-0.0045,0.0021,-0.0083,-0.2216 

$	13-Dec-2018	21:07:16.227	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000098	-9756502883531006900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	336431133914862330000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:16.227	Ascend	SBE41 Message						   13.84, 22.1631, 35.2119  	13.840000	14.861201	0.001831	0.010000	0.010000	0.040358	1.000000																							

$	13-Dec-2018	21:07:16.361	Ascend	Optode Message																												4330,1532,265.756,22.427,29.140,29.070,36.120,7.050,531.0,463.7,112.7  								

$	13-Dec-2018	21:07:17.412	Ascend	Optode post: 4330,1532,265.756,22.427,29.140,29.070,36.120,7.050,531.0,463.7,112.7  

$	13-Dec-2018	21:07:16.361	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:07:17.831	Ascend	PTH Message														784.614014	23.758333	52.109283	24.546975																			

$	13-Dec-2018	21:07:18.033	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.840000	143.584765	29.425000	217.500000																																

$	13-Dec-2018	21:07:18.146	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.7092437

$	13-Dec-2018	21:07:18.251	Ascend	FLBB Message																											/99/99,99:99:99,695,2312,700,4130,533  									

$	13-Dec-2018	21:07:18.362	Ascend	FLBB post: /99/99,99:99:99,695,2312,700,4130,533  

$	13-Dec-2018	21:07:17.298	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019934	282938583622399190000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-9756502883531006900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:17.298	Ascend	SBE41 Message						   13.85, 22.1633, 35.2119  	13.850000	14.492753	0.059963	-0.010000	0.000000	0.042236	1.000000																							

$	13-Dec-2018	21:07:18.250	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019867	-8205218925049576500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	282938583622399190000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:18.250	Ascend	SBE41 Message						   13.84, 22.1635, 35.2116  	13.840000	14.151808	0.118558	0.010000	0.000000	0.045084	1.000000																							

$	13-Dec-2018	21:07:19.073	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:07:19.476	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.840000	144.429408	29.425000	217.500000																																

$	13-Dec-2018	21:07:19.589	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4372654

$	13-Dec-2018	21:07:19.273	Ascend	Vel PID Values																		0.050000	0.110001	0.109668	0.099734	237951348826437740000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-8205218925049576500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:19.273	Ascend	SBE41 Message						   13.73, 22.1634, 35.2122  	13.730000	13.945561	0.156823	0.110001	0.060000	0.048314	1.000000																							

$	13-Dec-2018	21:07:20.248	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.730000	144.429758	29.425000	217.500000																																

$	13-Dec-2018	21:07:20.595	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:07:20.193	Ascend	Vel PID Values																		0.050000	0.120000	0.119966	0.010298	-6900589115966693600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	237951348826437740000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:20.193	Ascend	SBE41 Message						   13.61, 22.1636, 35.2119  	13.610000	13.866250	0.172459	0.120000	0.115000	0.051422	1.000000																							

$	13-Dec-2018	21:07:22.255	Ascend	Error executing 2485 Transaction = 0

$	13-Dec-2018	21:07:22.357	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.610000	250.000000	29.425000	217.500000																																

$	13-Dec-2018	21:07:22.469	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8740717

$	13-Dec-2018	21:07:22.573	Ascend	MSC: RX: 0x3AD3,A,02/01/2012 03:32:27,0,-1.00,-1.0000,-1.0000,253,163,1,66,22.54,54.72,11.576,5.254e-01,10695.00,2251.00,1169.79,13.97,-2741077F77A3C7AC079897700733E6F266AF2671A63C761185F675E995EAA5FC76180641067706B80702275667B508127870C8CC091B995EE98C89A4E9A209854951F90438A8B84027DA2771970CF6B1E6604615A5D6259E1570B549052AD51044FD0D644F130C647E7C0964BBE8B037,062722755.606 

$	13-Dec-2018	21:07:22.584	Ascend	MSC: Data: 0x3AD3,A,02/01/2012 03:32:27,0,-1.00,-1.0000,-1.0000,253,163,1,66,22.54,54.72,11.576,5.254e-01,10695.00,2251.00,1169.79,13.97,-2741077F77A3C7AC079897700733E6F266AF2671A63C761185F675E995EAA5FC76180641067706B80702275667B508127870C8CC091B995EE98C89A4E9A209854951F90438A8B84027DA2771970CF6B1E6604615A5D6259E1570B549052AD51044FD0D644F130C647E7C0964BBE8B037,062722755.606 

$	13-Dec-2018	21:07:22.793	Ascend	MSC post: 062722755.606

$	13-Dec-2018	21:07:22.895	Ascend	MSC: RX: 7 

$	13-Dec-2018	21:07:22.997	Ascend	MSC: RX: BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB

$	13-Dec-2018	21:07:21.342	Ascend	Vel PID Values																		0.050000	-0.960000	-0.956406	-1.076372	200117084363034120000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-6900589115966693600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:21.342	Ascend	SBE41 Message						   14.57, 22.1646, 35.2107  	14.570000	13.844306	0.176065	-0.960000	-0.420000	0.054156	1.000000																							

$	13-Dec-2018	21:07:22.191	Ascend	Vel PID Values																		0.050000	-0.030001	-0.033090	0.923317	-5803395446527989400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	200117084363034120000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:22.191	Ascend	SBE41 Message						   14.60, 22.1646, 35.2114  	14.600000	13.828359	0.174385	-0.030001	-0.495000	0.056529	1.000000																							

$	13-Dec-2018	21:07:23.192	Ascend	Vel PID Values																		0.050000	0.000000	-0.000105	0.032985	168298467949311680000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.00000	-5803395446527989400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:23.192	Ascend	SBE41 Message						   14.60, 22.1649, 35.2106  	14.600000	13.816381	0.161450	0.000000	-0.015000	0.058517	1.000000																							

$	13-Dec-2018	21:07:24.364	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	14.600000	144.396402	29.425000	217.500000																																

$	13-Dec-2018	21:07:24.477	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0025033

$	13-Dec-2018	21:07:24.482	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:07:24.681	Ascend	Starting pH sample

$	13-Dec-2018	21:07:24.685	Ascend	MSC: OUT: W

$	13-Dec-2018	21:07:25.135	Ascend	MSC: OUT: W

$	13-Dec-2018	21:07:24.190	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010072	-4880655570530038800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000	168298467949311680000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.00000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:24.190	Ascend	SBE41 Message						   14.59, 22.1646, 35.2112  	14.590000	13.861027	0.123691	0.010000	0.005000	0.059914	1.000000																							

$	13-Dec-2018	21:07:25.499	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:07:25.698	Ascend	MSC: Got ACK

$	13-Dec-2018	21:07:25.237	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	141539011545371120000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.00	-4880655570530038800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:25.237	Ascend	SBE41 Message						   14.59, 22.1654, 35.2107  	14.590000	14.018308	0.058671	0.000000	0.005000	0.060298	1.000000																							

$	13-Dec-2018	21:07:26.359	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	14.590000	144.018844	29.425000	217.500000																																

$	13-Dec-2018	21:07:26.470	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9883072

$	13-Dec-2018	21:07:26.574	Ascend	MSC: OUT: MODE,2

$	13-Dec-2018	21:07:26.680	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:07:26.684	Ascend	MSC: Got ACK

$	13-Dec-2018	21:07:26.187	Ascend	Vel PID Values																		0.050000	0.100000	0.099668	0.099634	-4104631334815762700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.	141539011545371120000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.00	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:26.187	Ascend	SBE41 Message						   14.49, 22.1653, 35.2114  	14.490000	14.254986	-0.012757	0.100000	0.050000	0.059426	1.000000																							

$	13-Dec-2018	21:07:27.237	Ascend	MSC: RX: ACK,MODE,2 

$	13-Dec-2018	21:07:27.543	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	14.490000	143.997148	29.425000	217.500000																																

$	13-Dec-2018	21:07:27.654	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1782088

$	13-Dec-2018	21:07:27.236	Ascend	Vel PID Values																		0.050000	1.130000	1.126572	1.026904	119034308709657110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-4104631334815762700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:27.236	Ascend	SBE41 Message						   13.36, 22.1652, 35.2124  	13.360000	14.458978	-0.063497	1.130000	0.615000	0.057432	1.000000																							

$	13-Dec-2018	21:07:28.311	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.360000	144.205742	29.425000	217.500000																																

$	13-Dec-2018	21:07:28.660	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:07:28.187	Ascend	Vel PID Values																		0.050000	0.290000	0.292790	-0.833782	-34519949525800558000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	119034308709657110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:28.187	Ascend	SBE41 Message						   13.07, 22.1656, 35.2117  	13.070000	14.556247	-0.085357	0.290000	0.710000	0.054780	1.000000																							

$	13-Dec-2018	21:07:29.318	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.070000	144.225873	29.425000	217.500000																																

$	13-Dec-2018	21:07:29.186	Ascend	Vel PID Values																		0.050000	0.000000	0.000970	-0.291820	100107853624821620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-34519949525800558000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:29.186	Ascend	SBE41 Message						   13.07, 22.1650, 35.2124  	13.070000	14.539956	-0.086080	0.000000	0.145000	0.051887	1.000000																							

$	13-Dec-2018	21:07:30.217	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.070000	144.274421	29.425000	217.500000																																

$	13-Dec-2018	21:07:30.660	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:07:30.184	Ascend	Vel PID Values																		0.050000	0.000000	0.000002	-0.000968	-29031277551198271000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	100107853624821620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:30.184	Ascend	SBE41 Message						   13.07, 22.1650, 35.2127  	13.070000	14.390180	-0.069542	0.000000	0.000000	0.049246	1.000000																							

$	13-Dec-2018	21:07:31.319	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.070000	144.278862	29.425000	217.500000																																

$	13-Dec-2018	21:07:31.661	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:07:31.182	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000002	841907048984749810000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-29031277551198271000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:31.182	Ascend	SBE41 Message						   13.07, 22.1661, 35.2118  	13.070000	14.079534	-0.032599	0.000000	0.000000	0.047425	1.000000																							

$	13-Dec-2018	21:07:32.318	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.070000	144.460469	29.425000	217.500000																																

$	13-Dec-2018	21:07:32.182	Ascend	Vel PID Values																		0.050000	0.020000	0.019933	0.019933	-24415304420557745000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	841907048984749810000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:32.182	Ascend	SBE41 Message						   13.05, 22.1660, 35.2111  	13.050000	13.676178	0.022834	0.020000	0.010000	0.046710	1.000000																							

$	13-Dec-2018	21:07:33.219	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.050000	144.463167	29.425000	217.500000																																

$	13-Dec-2018	21:07:33.180	Ascend	Vel PID Values																		0.050000	0.170000	0.169501	0.149568	708043828196174660000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-24415304420557745000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:33.180	Ascend	SBE41 Message						   12.88, 22.1651, 35.2120  	12.880000	13.333504	0.084709	0.170000	0.095000	0.046803	1.000000																							

$	13-Dec-2018	21:07:34.216	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.880000	144.475318	29.425000	217.500000																																

$	13-Dec-2018	21:07:34.181	Ascend	Vel PID Values																		0.050000	-0.330000	-0.328337	-0.497838	-20533271017689063000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	708043828196174660000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:34.181	Ascend	SBE41 Message						   13.21, 22.1659, 35.2127  	13.210000	13.144422	0.137407	-0.330000	-0.080000	0.047107	1.000000																							

$	13-Dec-2018	21:07:35.215	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.210000	144.466676	29.425000	217.500000																																

$	13-Dec-2018	21:07:35.179	Ascend	Vel PID Values																		0.050000	-0.680000	-0.678833	-0.350496	595464859512982760000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-20533271017689063000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:35.179	Ascend	SBE41 Message						   13.89, 22.1660, 35.2120  	13.890000	13.075315	0.171206	-0.680000	-0.505000	0.047281	1.000000																							

$	13-Dec-2018	21:07:36.215	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.890000	144.501790	29.425000	217.500000																																

$	13-Dec-2018	21:07:36.179	Ascend	Vel PID Values																		0.050000	0.010000	0.007706	0.686539	-17268480925876501000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	595464859512982760000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:36.179	Ascend	SBE41 Message						   13.88, 22.1668, 35.2115  	13.880000	13.052492	0.186057	0.010000	-0.335000	0.047522	1.000000																							

$	13-Dec-2018	21:07:37.215	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.880000	144.511446	29.425000	217.500000																																

$	13-Dec-2018	21:07:37.177	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019904	-0.027610	500785946850418500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-17268480925876501000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:37.177	Ascend	SBE41 Message						   13.90, 22.1658, 35.2115  	13.900000	13.062743	0.182749	-0.020000	-0.005000	0.048210	1.000000																							

$	13-Dec-2018	21:07:38.215	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.900000	144.552410	29.425000	217.500000																																

$	13-Dec-2018	21:07:38.176	Ascend	Vel PID Values																		0.050000	0.020000	0.019867	0.039770	-14522792458662137000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	500785946850418500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:38.176	Ascend	SBE41 Message						   13.88, 22.1664, 35.2121  	13.880000	13.156393	0.152611	0.020000	0.000000	0.049356	1.000000																							

$	13-Dec-2018	21:07:39.231	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.880000	144.550994	29.425000	217.500000																																

$	13-Dec-2018	21:07:39.175	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009901	-0.029767	421160981301201960000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-14522792458662137000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:39.175	Ascend	SBE41 Message						   13.89, 22.1662, 35.2125  	13.890000	13.359259	0.089081	-0.010000	0.005000	0.050369	1.000000																							

$	13-Dec-2018	21:07:40.216	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.890000	144.649535	29.425000	217.500000																																

$	13-Dec-2018	21:07:40.174	Ascend	Vel PID Values																		0.050000	0.340000	0.338836	0.348736	-12213668457734857000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	421160981301201960000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:40.174	Ascend	SBE41 Message						   13.55, 22.1669, 35.2118  	13.550000	13.603591	0.008970	0.340000	0.165000	0.050705	1.000000																							

$	13-Dec-2018	21:07:41.215	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.550000	144.649573	29.425000	217.500000																																

$	13-Dec-2018	21:07:41.172	Ascend	Vel PID Values																		0.050000	1.070001	1.067569	0.728734	354196385274310830000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-12213668457734857000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:41.172	Ascend	SBE41 Message						   12.48, 22.1664, 35.2124  	12.480000	13.783629	-0.055687	1.070001	0.705000	0.050334	1.000000																							

$	13-Dec-2018	21:07:42.215	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.480000	144.694984	29.425000	217.500000																																

$	13-Dec-2018	21:07:42.659	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:07:42.171	Ascend	Vel PID Values																		0.050000	0.110000	0.113190	-0.954379	-10271695172955014000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	354196385274310830000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:42.171	Ascend	SBE41 Message						   12.37, 22.1679, 35.2113  	12.370000	13.852449	-0.087601	0.110000	0.590000	0.049525	1.000000																							

$	13-Dec-2018	21:07:43.316	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.370000	144.715413	29.425000	217.500000																																

$	13-Dec-2018	21:07:43.170	Ascend	Vel PID Values																		0.050000	0.000000	0.000371	-0.112819	297879160015695400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-10271695172955014000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:43.170	Ascend	SBE41 Message						   12.37, 22.1678, 35.2119  	12.370000	13.805715	-0.090386	0.000000	0.055000	0.048690	1.000000																							

$	13-Dec-2018	21:07:44.215	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.370000	144.824423	29.425000	217.500000																																

$	13-Dec-2018	21:07:44.660	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:07:44.170	Ascend	Vel PID Values																		0.050000	0.010000	0.009968	0.009596	-86384956404551665000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	297879160015695400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:44.170	Ascend	SBE41 Message						   12.36, 22.1674, 35.2124  	12.360000	13.614973	-0.069625	0.010000	0.005000	0.048327	1.000000																							

$	13-Dec-2018	21:07:45.317	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.360000	144.834533	29.425000	217.500000																																

$	13-Dec-2018	21:07:45.660	Ascend	MSC: RX: 0x0E19,pH,02/01/2012 03:32:53,0,-1.00,-1.0000,-1.0000,278,163,0,22.55,54.72,11.744,4.660e-02,7.1234,0.000,-1.012260,0.001049,-1.08,+1.889e-07 

$	13-Dec-2018	21:07:45.667	Ascend	MSC: Data: 0x0E19,pH,02/01/2012 03:32:53,0,-1.00,-1.0000,-1.0000,278,163,0,22.55,54.72,11.744,4.660e-02,7.1234,0.000,-1.012260,0.001049,-1.08,+1.889e-07 

$	13-Dec-2018	21:07:45.870	Ascend	MSC post: 7.1234

$	13-Dec-2018	21:07:45.202	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	250516373573199840000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-86384956404551665000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:45.202	Ascend	SBE41 Message						   12.36, 22.1678, 35.2122  	12.360000	13.271215	-0.025830	0.000000	0.005000	0.049019	1.000000																							

$	13-Dec-2018	21:07:46.211	Ascend	Vel PID Values																		0.050000	0.089999	0.089700	0.089667	-72649748336227956000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	250516373573199840000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:46.211	Ascend	SBE41 Message						   12.27, 22.1678, 35.2124  	12.270000	12.871923	0.035166	0.089999	0.045000	0.050936	1.000000																							

$	13-Dec-2018	21:07:46.887	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.270000	144.997358	29.425000	217.500000																																

$	13-Dec-2018	21:07:46.999	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3393535

$	13-Dec-2018	21:07:47.104	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:07:47.108	Ascend	MSC: OUT: SLP

$	13-Dec-2018	21:07:47.206	Ascend	Vel PID Values																		0.050000	0.200001	0.199634	0.109934	210684270175061080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-72649748336227956000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:47.206	Ascend	SBE41 Message						   12.07, 22.1671, 35.2129  	12.070000	12.566286	0.098098	0.200001	0.145000	0.053603	1.000000																							

$	13-Dec-2018	21:07:47.864	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.070000	145.009801	29.425000	217.500000																																

$	13-Dec-2018	21:07:48.007	Ascend	MSC: RX: ACK,SLP 

$	13-Dec-2018	21:07:48.311	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.070000	145.009503	29.425000	217.500000																																

$	13-Dec-2018	21:07:48.166	Ascend	Vel PID Values																		0.050000	-1.070001	-1.065775	-1.265409	-61098438350767703000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	210684270175061080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:48.166	Ascend	SBE41 Message						   13.14, 22.1679, 35.2117  	13.140000	12.412547	0.147368	-1.070001	-0.435000	0.056290	1.000000																							

$	13-Dec-2018	21:07:49.248	Ascend	Vel PID Values																		0.050000	-0.049999	-0.053387	1.012388	177185471217226330000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-61098438350767703000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:49.248	Ascend	SBE41 Message						   13.19, 22.1680, 35.2124  	13.190000	12.354716	0.176804	-0.049999	-0.560000	0.058324	1.000000																							

$	13-Dec-2018	21:07:49.917	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.190000	145.010956	29.425000	217.500000																																

$	13-Dec-2018	21:07:50.030	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0238116

$	13-Dec-2018	21:07:50.336	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.190000	145.180508	29.425000	217.500000																																

$	13-Dec-2018	21:07:50.163	Ascend	Vel PID Values																		0.050000	-0.020000	-0.020106	0.033281	-51383786652995640000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	177185471217226330000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:50.163	Ascend	SBE41 Message						   13.21, 22.1680, 35.2127  	13.210000	12.335180	0.187723	-0.020000	-0.035000	0.059436	1.000000																							

$	13-Dec-2018	21:07:51.174	Ascend	Vel PID Values																		0.050000	0.000000	-0.000067	0.020039	149012981293687350000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-51383786652995640000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:51.174	Ascend	SBE41 Message						   13.21, 22.1688, 35.2119  	13.210000	12.380124	0.176357	0.000000	-0.010000	0.059463	1.000000																							

$	13-Dec-2018	21:07:51.946	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.210000	145.373367	29.425000	217.500000																																

$	13-Dec-2018	21:07:52.058	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0228452

$	13-Dec-2018	21:07:52.364	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.210000	145.732328	29.425000	217.500000																																

$	13-Dec-2018	21:07:52.162	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.010034	-43213764575169334000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	149012981293687350000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:52.162	Ascend	SBE41 Message						   13.20, 22.1685, 35.2095  	13.200000	12.547094	0.132089	0.010000	0.005000	0.058149	1.000000																							

$	13-Dec-2018	21:07:53.160	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	125319917267991080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-43213764575169334000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:53.160	Ascend	SBE41 Message						   13.20, 22.1680, 35.2113  	13.200000	12.806036	0.057532	0.000000	0.005000	0.055364	1.000000																							

$	13-Dec-2018	21:07:53.974	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	13.200000	145.918414	29.425000	217.500000																																

$	13-Dec-2018	21:07:54.085	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0224195

$	13-Dec-2018	21:07:54.190	Ascend	Vel PID Values																		0.050000	1.030000	1.026572	1.026539	-36342776007717417000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	125319917267991080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:54.190	Ascend	SBE41 Message						   12.17, 22.1683, 35.2128  	12.170000	13.037584	-0.020501	1.030000	0.515000	0.051371	1.000000																							

$	13-Dec-2018	21:07:54.744	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.170000	146.309160	29.425000	217.500000																																

$	13-Dec-2018	21:07:55.295	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	12.170000	146.437421	29.425000	217.500000																																

$	13-Dec-2018	21:07:55.160	Ascend	Vel PID Values																		0.050000	0.490000	0.491791	-0.534781	105394050422380510000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-36342776007717417000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:55.160	Ascend	SBE41 Message						   11.68, 22.1691, 35.2117  	11.680000	13.158723	-0.073300	0.490000	0.760000	0.046976	1.000000																							

$	13-Dec-2018	21:07:56.157	Ascend	Vel PID Values																		0.050000	-0.009999	-0.008332	-0.500123	-30564274622490348000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	105394050422380510000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:56.157	Ascend	SBE41 Message						   11.69, 22.1692, 35.2127  	11.690000	13.165381	-0.093157	-0.009999	0.240000	0.043189	1.000000																							

$	13-Dec-2018	21:07:57.001	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20  Pres, BP, BatV, BatI: 	11.690000	146.444045	29.425000	217.500000																																

$	13-Dec-2018	21:07:57.114	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0213524

$	13-Dec-2018	21:07:57.228	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:07:57.233	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:07:57.835	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:07:57.851	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:07:58.051	Ascend	Sending FLBB run command

$	13-Dec-2018	21:07:58.055	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:07:58.162	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:07:58.361	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:07:58.477	Ascend	CTD post: 11.69	22.169	35.21

$	13-Dec-2018	21:07:57.217	Ascend	Vel PID Values																		0.050000	0.000000	-0.000030	0.008302	886363964052220130000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-30564274622490348000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:57.217	Ascend	SBE41 Message						   11.69, 22.1690, 35.2131  	11.690000	13.045319	-0.085473	0.000000	-0.005000	0.040921	1.000000																							

$	13-Dec-2018	21:07:58.157	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000030	-25704554957514384000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	886363964052220130000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:07:58.157	Ascend	SBE41 Message						   11.69, 22.1693, 35.2126  	11.690000	12.763232	-0.052997	0.000000	0.000000	0.040746	1.000000																							

$	13-Dec-2018	21:07:59.176	Ascend	Radiometer Message																																	SATFI40287,-0.0044,0.0009,-0.0073,-0.2329 			

$	13-Dec-2018	21:07:59.391	Ascend	Radiometer post: SATFI40287,-0.0044,0.0009,-0.0073,-0.2329 

$	13-Dec-2018	21:07:58.937	Ascend	Optode Message																												4330,1532,265.570,22.442,29.141,29.072,36.121,7.049,530.9,463.5,112.2  								

$	13-Dec-2018	21:07:59.610	Ascend	Optode post: 4330,1532,265.570,22.442,29.141,29.072,36.121,7.049,530.9,463.5,112.2  

$	13-Dec-2018	21:07:58.939	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:08:00.027	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.690000	146.384843	29.425000	217.500000																																

$	13-Dec-2018	21:08:00.140	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0208926

$	13-Dec-2018	21:08:00.244	Ascend	Starting ISUS sample

$	13-Dec-2018	21:08:00.347	Ascend	Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00

$	13-Dec-2018	21:08:00.352	Ascend	MSC: OUT: W

$	13-Dec-2018	21:08:00.802	Ascend	MSC: OUT: W

$	13-Dec-2018	21:07:59.160	Ascend	Vel PID Values																		0.050000	0.070000	0.069767	0.069767	745432093767917140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-25704554957514384000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:07:59.160	Ascend	SBE41 Message						   11.62, 22.1697, 35.2123  	11.620000	12.366051	0.001708	0.070000	0.035000	0.042552	1.000000																							

$	13-Dec-2018	21:08:01.263	Ascend	FLBB Message																											/99/99,99:99:99,695,2301,700,4130,532  									

$	13-Dec-2018	21:08:01.373	Ascend	FLBB post: /99/99,99:99:99,695,2301,700,4130,532  

$	13-Dec-2018	21:08:00.243	Ascend	Vel PID Values																		0.050000	0.190000	0.189600	0.119833	-21617530719269597000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	745432093767917140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:08:00.243	Ascend	SBE41 Message						   11.43, 22.1699, 35.2123  	11.430000	12.002043	0.067418	0.190000	0.130000	0.045708	1.000000																							

$	13-Dec-2018	21:08:01.735	Ascend	MSC: RX: 

$	13-Dec-2018	21:08:01.934	Ascend	MSC: RX: 

$	13-Dec-2018	21:08:02.037	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:08:02.041	Ascend	MSC: Got ACK

$	13-Dec-2018	21:08:01.262	Ascend	Vel PID Values																		0.050000	-0.820000	-0.816639	-1.006239	626908390858818350000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-21617530719269597000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:08:01.262	Ascend	SBE41 Message						   12.25, 22.1705, 35.2121  	12.250000	11.783427	0.126523	-0.820000	-0.315000	0.049358	1.000000																							

$	13-Dec-2018	21:08:02.796	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	12.250000	145.704776	29.425000	217.500000																																

$	13-Dec-2018	21:08:02.908	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.6644177

$	13-Dec-2018	21:08:02.243	Ascend	Vel PID Values																		0.050000	-0.280000	-0.281791	0.534848	-18180343334905731000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	626908390858818350000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:08:02.243	Ascend	SBE41 Message						   12.53, 22.1698, 35.2124  	12.530000	11.693782	0.166274	-0.280000	-0.550000	0.053044	1.000000																							

$	13-Dec-2018	21:08:03.568	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	12.530000	145.296164	29.425000	217.500000																																

$	13-Dec-2018	21:08:03.916	Ascend	MSC: OUT: CTD,0,0.0000,0.0000,0.0000

$	13-Dec-2018	21:08:03.251	Ascend	Vel PID Values																		0.050000	-0.020000	-0.020869	0.260922	527229956712266200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-18180343334905731000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:08:03.251	Ascend	SBE41 Message						   12.55, 22.1707, 35.2095  	12.550000	11.666089	0.184684	-0.020000	-0.150000	0.056473	1.000000																							

$	13-Dec-2018	21:08:04.165	Ascend	Vel PID Values																		0.050000	0.010000	0.009899	0.030768	-15289668744655720000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	527229956712266200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:08:04.165	Ascend	SBE41 Message						   12.54, 22.1700, 35.2131  	12.540000	11.698823	0.181439	0.010000	-0.005000	0.059220	1.000000																							

$	13-Dec-2018	21:08:04.734	Ascend	MSC: RX: NAK,CTD,EConvertErr: 0 

$	13-Dec-2018	21:08:04.836	Ascend	MSC: EConvertErr: 0

$	13-Dec-2018	21:08:05.141	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	12.540000	145.284019	29.425000	217.500000																																

$	13-Dec-2018	21:08:05.255	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3404424

$	13-Dec-2018	21:08:05.253	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019833	Infinity	-15289668744655720000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000	-50.000000	-409600.000000	1.000000										

$	13-Dec-2018	21:08:05.253	Ascend	SBE41 Message						   12.55, 22.1708, 35.2126  	12.550000	11.842459	0.148797	-0.010000	0.000000	0.060401	1.000000																							

$	13-Dec-2018	21:08:05.908	Ascend	RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	12.550000	145.196736	29.425000	217.500000																																

$	13-Dec-2018	21:08:06.357	Ascend	MSC: OUT: W

$	13-Dec-2018	21:08:06.613	Ascend	MSC: OUT: W

$	13-Dec-2018	21:08:06.147	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009901	NaN	Infinity	50.000000	409600.000000	1.000000										

$	13-Dec-2018	21:08:06.147	Ascend	SBE41 Message						   12.55, 22.1708, 35.2121  	12.550000	12.086543	0.083696	0.000000	-0.005000	0.059411	1.000000																							

$	13-Dec-2018	21:08:07.056	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:08:07.061	Ascend	MSC: Got ACK

$	13-Dec-2018	21:08:07.262	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:08:07.266	Ascend	MSC: Got ACK

$	13-Dec-2018	21:08:07.160	Ascend	Vel PID Values																		0.050000	0.820001	0.817272	0.817305	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:07.160	Ascend	SBE41 Message						   11.73, 22.1713, 35.2126  	11.730000	12.328205	0.004669	0.820001	0.410000	0.056337	1.000000																							

$	13-Dec-2018	21:08:08.008	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.730000	145.146109	29.425000	217.500000																																

$	13-Dec-2018	21:08:08.122	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7652716

$	13-Dec-2018	21:08:08.226	Ascend	MSC: OUT: MODE,1

$	13-Dec-2018	21:08:08.225	Ascend	Vel PID Values																		0.050000	0.690000	0.690428	-0.126844	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:08.225	Ascend	SBE41 Message						   11.04, 22.1713, 35.2128  	11.040000	12.474495	-0.058460	0.690000	0.755000	0.051944	1.000000																							

$	13-Dec-2018	21:08:08.876	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.040000	145.140029	29.425000	217.500000																																

$	13-Dec-2018	21:08:09.128	Ascend	MSC: RX: ACK,MODE,1 

$	13-Dec-2018	21:08:09.230	Ascend	Vel PID Values																		0.050000	0.010000	0.012264	-0.678164	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:09.230	Ascend	SBE41 Message						   11.03, 22.1719, 35.2126  	11.030000	12.505704	-0.089376	0.010000	0.350000	0.047109	1.000000																							

$	13-Dec-2018	21:08:09.776	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.030000	145.129204	29.425000	217.500000																																

$	13-Dec-2018	21:08:10.331	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.030000	145.131879	29.425000	217.500000																																

$	13-Dec-2018	21:08:11.129	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:08:10.144	Ascend	Vel PID Values																		0.050000	0.000000	0.000037	-0.012227	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:10.144	Ascend	SBE41 Message						   11.03, 22.1722, 35.2125  	11.030000	12.411540	-0.088830	0.000000	0.005000	0.042837	1.000000																							

$	13-Dec-2018	21:08:11.231	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010004	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:11.231	Ascend	SBE41 Message						   11.04, 22.1717, 35.2134  	11.040000	12.158116	-0.060911	-0.010000	-0.005000	0.040293	1.000000																							

$	13-Dec-2018	21:08:12.120	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.040000	145.135045	29.425000	217.500000																																

$	13-Dec-2018	21:08:12.232	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1037679

$	13-Dec-2018	21:08:12.231	Ascend	Vel PID Values																		0.050000	0.050000	0.049801	0.059767	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:12.231	Ascend	SBE41 Message						   10.99, 22.1718, 35.2134  	10.990000	11.775156	-0.009479	0.050000	0.020000	0.040341	1.000000																							

$	13-Dec-2018	21:08:12.883	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.990000	145.131133	29.425000	217.500000																																

$	13-Dec-2018	21:08:13.243	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:08:13.140	Ascend	Vel PID Values																		0.050000	0.150000	0.149667	0.099866	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:13.140	Ascend	SBE41 Message						   10.84, 22.1714, 35.2136  	10.840000	11.398137	0.054952	0.150000	0.100000	0.042734	1.000000																							

$	13-Dec-2018	21:08:13.891	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.840000	145.132676	29.425000	217.500000																																

$	13-Dec-2018	21:08:14.243	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:08:14.139	Ascend	Vel PID Values																		0.050000	0.060000	0.060299	-0.089367	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:14.139	Ascend	SBE41 Message						   10.78, 22.1722, 35.2128  	10.780000	11.153817	0.115399	0.060000	0.105000	0.046385	1.000000																							

$	13-Dec-2018	21:08:14.909	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.780000	145.112664	29.425000	217.500000																																

$	13-Dec-2018	21:08:15.138	Ascend	Vel PID Values																		0.050000	-1.080000	-1.076206	-1.136505	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:15.138	Ascend	SBE41 Message						   11.86, 22.1720, 35.2132  	11.860000	11.047162	0.158509	-1.080000	-0.510000	0.050321	1.000000																							

$	13-Dec-2018	21:08:15.788	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.860000	145.130709	29.425000	217.500000																																

$	13-Dec-2018	21:08:16.138	Ascend	Vel PID Values																		0.050000	0.000000	-0.003588	1.072618	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:16.138	Ascend	SBE41 Message						   11.86, 22.1723, 35.2105  	11.860000	11.001390	0.182269	0.000000	-0.540000	0.054135	1.000000																							

$	13-Dec-2018	21:08:16.787	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.860000	145.118922	29.425000	217.500000																																

$	13-Dec-2018	21:08:17.136	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009973	-0.006385	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:17.136	Ascend	SBE41 Message						   11.87, 22.1721, 35.2127  	11.870000	10.978016	0.189001	-0.010000	-0.005000	0.057613	1.000000																							

$	13-Dec-2018	21:08:17.787	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.870000	145.126350	29.425000	217.500000																																

$	13-Dec-2018	21:08:18.135	Ascend	Vel PID Values																		0.050000	0.030000	0.029867	0.039840	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:18.135	Ascend	SBE41 Message						   11.84, 22.1727, 35.2130  	11.840000	11.028184	0.171120	0.030000	0.010000	0.060160	1.000000																							

$	13-Dec-2018	21:08:18.789	Ascend	PTH Message														788.232910	23.575000	52.246613	24.536250																			

$	13-Dec-2018	21:08:18.992	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.840000	145.130463	30.575000	369.000000																																

$	13-Dec-2018	21:08:19.134	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019833	-0.049700	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:19.134	Ascend	SBE41 Message						   11.86, 22.1722, 35.2132  	11.860000	11.212782	0.116924	-0.020000	0.005000	0.060854	1.000000																							

$	13-Dec-2018	21:08:19.790	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.860000	145.132631	30.575000	369.000000																																

$	13-Dec-2018	21:08:20.134	Ascend	Vel PID Values																		0.050000	0.139999	0.139467	0.159301	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:20.134	Ascend	SBE41 Message						   11.72, 22.1723, 35.2134  	11.720000	11.484891	0.035899	0.139999	0.060000	0.059210	1.000000																							

$	13-Dec-2018	21:08:20.588	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:08:20.892	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.720000	145.130873	30.575000	369.000000																																

$	13-Dec-2018	21:08:21.132	Ascend	Vel PID Values																		0.050000	1.110001	1.106772	0.967305	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:21.132	Ascend	SBE41 Message						   10.61, 22.1722, 35.2141  	10.610000	11.712793	-0.038925	1.110001	0.625000	0.055639	1.000000																							

$	13-Dec-2018	21:08:21.788	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.610000	145.141043	30.575000	369.000000																																

$	13-Dec-2018	21:08:22.243	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:08:22.132	Ascend	Vel PID Values																		0.050000	0.259999	0.262823	-0.843949	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:22.132	Ascend	SBE41 Message						   10.35, 22.1726, 35.2090  	10.350000	11.817255	-0.082081	0.259999	0.685000	0.051027	1.000000																							

$	13-Dec-2018	21:08:23.094	Ascend	Error in I2CPortBase.Execute

$	13-Dec-2018	21:08:23.099	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.350000	145.141043	30.575000	369.000000																																

$	13-Dec-2018	21:08:23.307	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0647066

$	13-Dec-2018	21:08:23.615	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.350000	145.133689	30.575000	369.000000																																

$	13-Dec-2018	21:08:24.412	Ascend	MSC: RX: 0x5EE9,A,02/01/2012 03:33:29,0,-1.00,-1.0000,-1.0000,254,163,1,66,22.62,54.62,11.576,5.250e-01,10659.00,2229.00,1167.37,12.28,-245C2434440B03EF63D9D3D2F3D903F004118441D482E4D78535059F960E667B76E5A73E877C379FC7A9C796D76DF732C6F076AB966F463A860F55F555E895E9B5FC3617F6403674D6B4B701675547B37811586D78C92919395D898A39A259A0A981594BF90128A7883FE7D8576ED70BD6B1C6601613F5D3559D657075499529750E14FCE4F184EC44EBB,6722.6 

$	13-Dec-2018	21:08:24.522	Ascend	MSC: Data: 0x5EE9,A,02/01/2012 03:33:29,0,-1.00,-1.0000,-1.0000,254,163,1,66,22.62,54.62,11.576,5.250e-01,10659.00,2229.00,1167.37,12.28,-245C2434440B03EF63D9D3D2F3D903F004118441D482E4D78535059F960E667B76E5A73E877C379FC7A9C796D76DF732C6F076AB966F463A860F55F555E895E9B5FC3617F6403674D6B4B701675547B37811586D78C92919395D898A39A259A0A981594BF90128A7883FE7D8576ED70BD6B1C6601613F5D3559D657075499529750E14FCE4F184EC44EBB,6722.6 

$	13-Dec-2018	21:08:24.635	Ascend	MSC post: 6722.6

$	13-Dec-2018	21:08:23.484	Ascend	Vel PID Values																		0.050000	-0.009999	-0.009096	-0.271919	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:23.484	Ascend	SBE41 Message						   10.36, 22.1727, 35.2137  	10.360000	11.798737	-0.093005	-0.009999	0.125000	0.046180	1.000000																							

$	13-Dec-2018	21:08:24.130	Ascend	Vel PID Values																		0.050000	0.000000	-0.000032	0.009064	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:24.130	Ascend	SBE41 Message						   10.36, 22.1719, 35.2144  	10.360000	11.644849	-0.079646	0.000000	-0.005000	0.042360	1.000000																							

$	13-Dec-2018	21:08:25.127	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009935	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:25.127	Ascend	SBE41 Message						   10.37, 22.1721, 35.2120  	10.370000	11.333416	-0.044012	-0.010000	-0.005000	0.040627	1.000000																							

$	13-Dec-2018	21:08:25.967	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.370000	145.120911	30.575000	369.000000																																

$	13-Dec-2018	21:08:26.078	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6672288

$	13-Dec-2018	21:08:26.182	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:08:26.186	Ascend	Starting pH sample

$	13-Dec-2018	21:08:26.290	Ascend	MSC: OUT: W

$	13-Dec-2018	21:08:26.739	Ascend	MSC: OUT: W

$	13-Dec-2018	21:08:26.182	Ascend	Vel PID Values																		0.050000	0.099999	0.099633	0.109600	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:26.182	Ascend	SBE41 Message						   10.27, 22.1727, 35.2133  	10.270000	10.936148	0.011357	0.099999	0.045000	0.041509	1.000000																							

$	13-Dec-2018	21:08:27.185	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:08:27.191	Ascend	MSC: Got ACK

$	13-Dec-2018	21:08:27.390	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:08:27.395	Ascend	MSC: Got ACK

$	13-Dec-2018	21:08:27.185	Ascend	Vel PID Values																		0.050000	0.130000	0.129900	0.030266	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:27.185	Ascend	SBE41 Message						   10.14, 22.1728, 35.2141  	10.140000	10.604805	0.075211	0.130000	0.115000	0.044418	1.000000																							

$	13-Dec-2018	21:08:28.039	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.140000	145.139031	30.575000	369.000000																																

$	13-Dec-2018	21:08:28.153	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0686922

$	13-Dec-2018	21:08:28.256	Ascend	MSC: OUT: MODE,2

$	13-Dec-2018	21:08:28.150	Ascend	Vel PID Values																		0.050000	-0.040000	-0.039434	-0.169334	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:28.150	Ascend	SBE41 Message						   10.18, 22.1732, 35.2140  	10.180000	10.425178	0.131120	-0.040000	0.045000	0.048219	1.000000																							

$	13-Dec-2018	21:08:28.908	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.180000	145.122260	30.575000	369.000000																																

$	13-Dec-2018	21:08:29.159	Ascend	MSC: RX: ACK,MODE,2 

$	13-Dec-2018	21:08:29.124	Ascend	Vel PID Values																		0.050000	-0.929999	-0.927037	-0.887602	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:29.124	Ascend	SBE41 Message						   11.11, 22.1733, 35.2134  	11.110000	10.355881	0.167898	-0.929999	-0.485000	0.052104	1.000000																							

$	13-Dec-2018	21:08:29.806	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.110000	145.136751	30.575000	369.000000																																

$	13-Dec-2018	21:08:30.123	Ascend	Vel PID Values																		0.050000	0.009999	0.006876	0.933913	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:30.123	Ascend	SBE41 Message						   11.10, 22.1729, 35.2141  	11.100000	10.316932	0.185629	0.009999	-0.460000	0.055857	1.000000																							

$	13-Dec-2018	21:08:30.704	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.100000	145.146281	30.575000	369.000000																																

$	13-Dec-2018	21:08:31.158	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:08:31.123	Ascend	Vel PID Values																		0.050000	-0.009999	-0.009938	-0.016814	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:31.123	Ascend	SBE41 Message						   11.11, 22.1738, 35.2134  	11.110000	10.292255	0.186364	-0.009999	0.000000	0.059149	1.000000																							

$	13-Dec-2018	21:08:31.807	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.110000	145.122610	30.575000	369.000000																																

$	13-Dec-2018	21:08:32.122	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000062	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:32.122	Ascend	SBE41 Message						   11.12, 22.1735, 35.2137  	11.120000	10.342855	0.161042	-0.010000	-0.010000	0.061225	1.000000																							

$	13-Dec-2018	21:08:32.704	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.120000	145.132490	30.575000	369.000000																																

$	13-Dec-2018	21:08:33.159	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:08:33.120	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:33.120	Ascend	SBE41 Message						   11.11, 22.1741, 35.2135  	11.110000	10.520333	0.100560	0.010000	0.000000	0.061240	1.000000																							

$	13-Dec-2018	21:08:33.604	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:08:33.908	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.110000	145.139657	30.575000	369.000000																																

$	13-Dec-2018	21:08:34.118	Ascend	Vel PID Values																		0.050000	0.009999	0.009999	0.000065	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:34.118	Ascend	SBE41 Message						   11.10, 22.1744, 35.2128  	11.100000	10.772154	0.020282	0.009999	0.010000	0.059003	1.000000																							

$	13-Dec-2018	21:08:34.703	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	11.100000	145.128518	30.575000	369.000000																																

$	13-Dec-2018	21:08:35.117	Ascend	Vel PID Values																		0.050000	1.090000	1.086406	1.076407	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:35.117	Ascend	SBE41 Message						   10.01, 22.1743, 35.2134  	10.010000	10.978913	-0.046275	1.090000	0.550000	0.055117	1.000000																							

$	13-Dec-2018	21:08:35.703	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	10.010000	145.113371	30.575000	369.000000																																

$	13-Dec-2018	21:08:36.115	Ascend	Vel PID Values																		0.050000	0.410000	0.412257	-0.674149	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:36.115	Ascend	SBE41 Message						    9.60, 22.1741, 35.2144  	9.600000	11.077370	-0.080687	0.410000	0.750000	0.050430	1.000000																							

$	13-Dec-2018	21:08:36.703	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21  Pres, BP, BatV, BatI: 	9.600000	145.151742	30.575000	369.000000																																

$	13-Dec-2018	21:08:37.174	Ascend	ERROR: Missed PH message 7

$	13-Dec-2018	21:08:37.278	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:08:37.282	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:08:37.981	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:08:37.998	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:08:38.198	Ascend	Sending FLBB run command

$	13-Dec-2018	21:08:38.202	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:08:38.307	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:08:38.411	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:08:38.623	Ascend	CTD post: 9.60	22.175	35.21

$	13-Dec-2018	21:08:37.115	Ascend	Vel PID Values																		0.050000	0.000000	0.001368	-0.410889	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:37.115	Ascend	SBE41 Message						    9.60, 22.1750, 35.2139  	9.600000	11.072430	-0.088669	0.000000	0.205000	0.045824	1.000000																							

$	13-Dec-2018	21:08:38.198	Ascend	Vel PID Values																		0.050000	-0.009999	-0.009964	-0.011332	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:38.198	Ascend	SBE41 Message						    9.61, 22.1748, 35.2140  	9.610000	10.945005	-0.077737	-0.009999	-0.005000	0.042385	1.000000																							

$	13-Dec-2018	21:08:39.303	Ascend	Radiometer Message																																	SATFI40287,-0.0048,0.0019,-0.0073,-0.2196 			

$	13-Dec-2018	21:08:39.517	Ascend	Radiometer post: SATFI40287,-0.0048,0.0019,-0.0073,-0.2196 

$	13-Dec-2018	21:08:39.074	Ascend	Optode Message																												4330,1532,265.564,22.457,29.136,29.066,36.118,7.052,530.8,463.4,111.8  								

$	13-Dec-2018	21:08:39.736	Ascend	Optode post: 4330,1532,265.564,22.457,29.136,29.066,36.118,7.052,530.8,463.4,111.8  

$	13-Dec-2018	21:08:39.075	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:08:40.153	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.610000	145.151094	30.575000	369.000000																																

$	13-Dec-2018	21:08:40.265	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1061416

$	13-Dec-2018	21:08:39.112	Ascend	Vel PID Values																		0.050000	0.030000	0.029867	0.039830	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:39.112	Ascend	SBE41 Message						    9.58, 22.1751, 35.2139  	9.580000	10.655722	-0.045005	0.030000	0.010000	0.041219	1.000000																							

$	13-Dec-2018	21:08:40.709	Ascend	FLBB Message																											/99/99,99:99:99,695,2312,700,4130,532  									

$	13-Dec-2018	21:08:40.821	Ascend	FLBB post: /99/99,99:99:99,695,2312,700,4130,532  

$	13-Dec-2018	21:08:40.112	Ascend	Vel PID Values																		0.050000	0.110000	0.109733	0.079867	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:40.112	Ascend	SBE41 Message						    9.47, 22.1748, 35.2146  	9.470000	10.256633	0.010636	0.110000	0.070000	0.042586	1.000000																							

$	13-Dec-2018	21:08:41.469	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.470000	145.140797	30.575000	369.000000																																

$	13-Dec-2018	21:08:41.582	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3111501

$	13-Dec-2018	21:08:41.153	Ascend	Vel PID Values																		0.050000	0.140000	0.139900	0.030167	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:41.153	Ascend	SBE41 Message						    9.33, 22.1746, 35.2147  	9.330000	9.898577	0.076907	0.140000	0.125000	0.045770	1.000000																							

$	13-Dec-2018	21:08:42.231	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.330000	145.122245	30.575000	369.000000																																

$	13-Dec-2018	21:08:42.111	Ascend	Vel PID Values																		0.050000	-0.580000	-0.577604	-0.717504	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:42.111	Ascend	SBE41 Message						    9.91, 22.1751, 35.2139  	9.910000	9.686230	0.134354	-0.580000	-0.220000	0.049728	1.000000																							

$	13-Dec-2018	21:08:43.231	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.910000	145.139754	30.575000	369.000000																																

$	13-Dec-2018	21:08:43.110	Ascend	Vel PID Values																		0.050000	-0.460000	-0.460395	0.117209	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:43.110	Ascend	SBE41 Message						   10.37, 22.1743, 35.2145  	10.370000	9.593777	0.171385	-0.460000	-0.520000	0.053748	1.000000																							

$	13-Dec-2018	21:08:44.232	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	10.370000	145.141624	30.575000	369.000000																																

$	13-Dec-2018	21:08:44.109	Ascend	Vel PID Values																		0.050000	-0.020000	-0.021465	0.438930	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:44.109	Ascend	SBE41 Message						   10.39, 22.1752, 35.2142  	10.390000	9.551149	0.188836	-0.020000	-0.240000	0.057434	1.000000																							

$	13-Dec-2018	21:08:45.233	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	10.390000	145.138167	30.575000	369.000000																																

$	13-Dec-2018	21:08:45.107	Ascend	Vel PID Values																		0.050000	0.010000	0.009898	0.031363	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:45.107	Ascend	SBE41 Message						   10.38, 22.1750, 35.2143  	10.380000	9.557535	0.187414	0.010000	-0.005000	0.060112	1.000000																							

$	13-Dec-2018	21:08:45.933	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:08:46.132	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009865	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:46.132	Ascend	SBE41 Message						   10.38, 22.1756, 35.2139  	10.380000	9.669371	0.157794	0.000000	0.005000	0.061033	1.000000																							

$	13-Dec-2018	21:08:46.678	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	10.380000	145.138726	30.575000	369.000000																																

$	13-Dec-2018	21:08:46.790	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1034407

$	13-Dec-2018	21:08:47.095	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	10.380000	145.135827	30.575000	369.000000																																

$	13-Dec-2018	21:08:47.796	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:08:47.205	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:47.205	Ascend	SBE41 Message						   10.38, 22.1754, 35.2139  	10.380000	9.892111	0.094447	0.000000	0.000000	0.059728	1.000000																							

$	13-Dec-2018	21:08:48.442	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	10.380000	145.147108	30.575000	369.000000																																

$	13-Dec-2018	21:08:48.796	Ascend	MSC: RX: 0x93C6,pH,02/01/2012 03:33:57,0,-1.00,-1.0000,-1.0000,279,163,0,22.65,54.57,11.744,4.620e-02,7.1234,0.000,-0.968641,0.000754,-0.

$	13-Dec-2018	21:08:48.900	Ascend	MSC: Data: 0x93C6,pH,02/01/2012 03:33:57,0,-1.00,-1.0000,-1.0000,279,163,0,22.65,54.57,11.744,4.620e-02,7.1234,0.000,-0.968641,0.000754,-0.

$	13-Dec-2018	21:08:49.004	Ascend	MSC post: 7.1234

$	13-Dec-2018	21:08:48.308	Ascend	Vel PID Values																		0.050000	0.580000	0.578070	0.578070	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:48.308	Ascend	SBE41 Message						    9.80, 22.1753, 35.2147  	9.800000	10.134821	0.015058	0.580000	0.290000	0.056470	1.000000																							

$	13-Dec-2018	21:08:49.106	Ascend	Vel PID Values																		0.050000	0.880000	0.878999	0.300929	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:49.106	Ascend	SBE41 Message						    8.92, 22.1750, 35.2149  	8.920000	10.296288	-0.049209	0.880000	0.730000	0.052128	1.000000																							

$	13-Dec-2018	21:08:49.996	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.920000	145.145081	30.575000	369.000000																																

$	13-Dec-2018	21:08:50.108	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3123052

$	13-Dec-2018	21:08:50.211	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:08:50.215	Ascend	MSC: OUT: SLP

$	13-Dec-2018	21:08:50.106	Ascend	Vel PID Values																		0.050000	0.060000	0.062728	-0.816271	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:50.106	Ascend	SBE41 Message						    8.86, 22.1757, 35.2144  	8.860000	10.344120	-0.081406	0.060000	0.470000	0.047563	1.000000																							

$	13-Dec-2018	21:08:50.960	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.860000	145.128481	30.575000	369.000000																																

$	13-Dec-2018	21:08:51.115	Ascend	MSC: RX: ACK,SLP 

$	13-Dec-2018	21:08:51.100	Ascend	Vel PID Values																		0.050000	0.000000	0.000204	-0.062523	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:51.100	Ascend	SBE41 Message						    8.86, 22.1759, 35.2149  	8.860000	10.271692	-0.083899	0.000000	0.030000	0.043845	1.000000																							

$	13-Dec-2018	21:08:51.763	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.860000	145.126417	30.575000	369.000000																																

$	13-Dec-2018	21:08:52.100	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000204	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:52.100	Ascend	SBE41 Message						    8.86, 22.1763, 35.2146  	8.860000	10.048076	-0.061518	0.000000	0.000000	0.042061	1.000000																							

$	13-Dec-2018	21:08:52.662	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.860000	145.143390	30.575000	369.000000																																

$	13-Dec-2018	21:08:53.099	Ascend	Vel PID Values																		0.050000	0.070000	0.069767	0.069766	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:53.099	Ascend	SBE41 Message						    8.79, 22.1768, 35.2146  	8.790000	9.683764	-0.015655	0.070000	0.035000	0.042747	1.000000																							

$	13-Dec-2018	21:08:53.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.790000	145.151027	30.575000	369.000000																																

$	13-Dec-2018	21:08:54.097	Ascend	Vel PID Values																		0.050000	0.100000	0.099900	0.030133	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:54.097	Ascend	SBE41 Message						    8.69, 22.1770, 35.2147  	8.690000	9.295038	0.046288	0.100000	0.085000	0.045475	1.000000																							

$	13-Dec-2018	21:08:54.659	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.690000	145.141631	30.575000	369.000000																																

$	13-Dec-2018	21:08:55.098	Ascend	Vel PID Values																		0.050000	0.070000	0.070099	-0.029801	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:55.098	Ascend	SBE41 Message						    8.62, 22.1767, 35.2152  	8.620000	9.018725	0.108052	0.070000	0.085000	0.049278	1.000000																							

$	13-Dec-2018	21:08:55.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.620000	145.140730	30.575000	369.000000																																

$	13-Dec-2018	21:08:56.096	Ascend	Vel PID Values																		0.050000	-1.010000	-1.006406	-1.076505	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:56.096	Ascend	SBE41 Message						    9.63, 22.1772, 35.2052  	9.630000	8.884439	0.154712	-1.010000	-0.470000	0.053370	1.000000																							

$	13-Dec-2018	21:08:56.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.630000	145.164289	30.575000	369.000000																																

$	13-Dec-2018	21:08:57.095	Ascend	Vel PID Values																		0.050000	-0.040000	-0.043222	0.963184	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:57.095	Ascend	SBE41 Message						    9.67, 22.1769, 35.2146  	9.670000	8.826294	0.181884	-0.040000	-0.525000	0.057371	1.000000																							

$	13-Dec-2018	21:08:57.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.670000	145.163439	30.575000	369.000000																																

$	13-Dec-2018	21:08:58.094	Ascend	Vel PID Values																		0.050000	0.010000	0.009828	0.053050	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:58.094	Ascend	SBE41 Message						    9.66, 22.1776, 35.2141  	9.660000	8.801300	0.190877	0.010000	-0.015000	0.060867	1.000000																							

$	13-Dec-2018	21:08:58.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.660000	145.152844	30.575000	369.000000																																

$	13-Dec-2018	21:08:59.093	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019762	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:08:59.093	Ascend	SBE41 Message						    9.67, 22.1768, 35.2149  	9.670000	8.851182	0.175723	-0.010000	0.000000	0.063052	1.000000																							

$	13-Dec-2018	21:08:59.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.670000	145.138465	30.575000	369.000000																																

$	13-Dec-2018	21:09:00.090	Ascend	Vel PID Values																		0.050000	-0.010000	-0.010000	-0.000066	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:00.090	Ascend	SBE41 Message						    9.68, 22.1774, 35.2143  	9.680000	9.029954	0.125932	-0.010000	-0.010000	0.063087	1.000000																							

$	13-Dec-2018	21:09:00.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.680000	145.156592	30.575000	369.000000																																

$	13-Dec-2018	21:09:01.089	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:01.089	Ascend	SBE41 Message						    9.67, 22.1769, 35.2143  	9.670000	9.292823	0.048351	0.010000	0.000000	0.060816	1.000000																							

$	13-Dec-2018	21:09:01.659	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	9.670000	145.154186	30.575000	369.000000																																

$	13-Dec-2018	21:09:02.090	Ascend	Vel PID Values																		0.050000	0.890000	0.887072	0.877138	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:02.090	Ascend	SBE41 Message						    8.78, 22.1776, 35.2149  	8.780000	9.516632	-0.027417	0.890000	0.450000	0.056862	1.000000																							

$	13-Dec-2018	21:09:02.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.780000	145.166732	30.575000	369.000000																																

$	13-Dec-2018	21:09:03.089	Ascend	Vel PID Values																		0.050000	0.580000	0.581027	-0.306045	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:03.089	Ascend	SBE41 Message						    8.20, 22.1781, 35.2148  	8.200000	9.628849	-0.075488	0.580000	0.735000	0.052106	1.000000																							

$	13-Dec-2018	21:09:03.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.200000	145.159513	30.575000	369.000000																																

$	13-Dec-2018	21:09:04.088	Ascend	Vel PID Values																		0.050000	0.000000	0.001932	-0.579095	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:04.088	Ascend	SBE41 Message						    8.20, 22.1785, 35.2146  	8.200000	9.636323	-0.093041	0.000000	0.290000	0.047539	1.000000																							

$	13-Dec-2018	21:09:04.659	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.200000	145.150587	30.575000	369.000000																																

$	13-Dec-2018	21:09:05.087	Ascend	Vel PID Values																		0.050000	0.000000	0.000003	-0.001929	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:05.087	Ascend	SBE41 Message						    8.20, 22.1782, 35.2140  	8.200000	9.530609	-0.087168	0.000000	0.000000	0.044182	1.000000																							

$	13-Dec-2018	21:09:05.659	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.200000	145.156138	30.575000	369.000000																																

$	13-Dec-2018	21:09:06.086	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009964	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:06.086	Ascend	SBE41 Message						    8.19, 22.1784, 35.2153  	8.190000	9.271494	-0.058206	0.010000	0.005000	0.042959	1.000000																							

$	13-Dec-2018	21:09:06.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.190000	145.158291	30.575000	369.000000																																

$	13-Dec-2018	21:09:07.085	Ascend	Vel PID Values																		0.050000	0.089999	0.089733	0.079766	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:07.085	Ascend	SBE41 Message						    8.10, 22.1779, 35.2150  	8.100000	8.892586	-0.005151	0.089999	0.050000	0.044084	1.000000																							

$	13-Dec-2018	21:09:07.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.100000	145.152360	30.575000	369.000000																																

$	13-Dec-2018	21:09:08.083	Ascend	Vel PID Values																		0.050000	0.080000	0.080033	-0.009700	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:08.083	Ascend	SBE41 Message						    8.02, 22.1780, 35.2149  	8.020000	8.531383	0.061668	0.080000	0.085000	0.046907	1.000000																							

$	13-Dec-2018	21:09:08.663	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.020000	145.140842	30.575000	369.000000																																

$	13-Dec-2018	21:09:09.082	Ascend	Vel PID Values																		0.050000	0.000000	0.000266	-0.079766	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:09.082	Ascend	SBE41 Message						    8.02, 22.1781, 35.2152  	8.020000	8.303435	0.122409	0.000000	0.040000	0.050484	1.000000																							

$	13-Dec-2018	21:09:09.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.020000	145.148449	30.575000	369.000000																																

$	13-Dec-2018	21:09:10.083	Ascend	Vel PID Values																		0.050000	-0.860000	-0.857137	-0.857404	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:10.083	Ascend	SBE41 Message						    8.88, 22.1786, 35.2149  	8.880000	8.202194	0.162637	-0.860000	-0.430000	0.054196	1.000000																							

$	13-Dec-2018	21:09:10.666	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.880000	145.144276	30.575000	369.000000																																

$	13-Dec-2018	21:09:11.080	Ascend	Vel PID Values																		0.050000	-0.020000	-0.022790	0.834347	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:11.080	Ascend	SBE41 Message						    8.90, 22.1783, 35.2155  	8.900000	8.154440	0.182426	-0.020000	-0.440000	0.057783	1.000000																							

$	13-Dec-2018	21:09:11.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.900000	145.144135	30.575000	369.000000																																

$	13-Dec-2018	21:09:12.078	Ascend	Vel PID Values																		0.050000	0.000000	-0.000071	0.022719	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:12.078	Ascend	SBE41 Message						    8.90, 22.1793, 35.2135  	8.900000	8.131833	0.186128	0.000000	-0.010000	0.060856	1.000000																							

$	13-Dec-2018	21:09:12.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.900000	145.127535	30.575000	369.000000																																

$	13-Dec-2018	21:09:13.078	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000071	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:13.078	Ascend	SBE41 Message						    8.90, 22.1788, 35.2152  	8.900000	8.180940	0.166950	0.000000	0.000000	0.062650	1.000000																							

$	13-Dec-2018	21:09:13.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.900000	145.148940	30.575000	369.000000																																

$	13-Dec-2018	21:09:14.076	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	0.000000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:14.076	Ascend	SBE41 Message						    8.90, 22.1791, 35.2149  	8.900000	8.346180	0.114446	0.000000	0.000000	0.062428	1.000000																							

$	13-Dec-2018	21:09:14.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.900000	145.147458	30.575000	369.000000																																

$	13-Dec-2018	21:09:15.077	Ascend	Vel PID Values																		0.050000	0.009999	0.009966	0.009966	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:15.077	Ascend	SBE41 Message						    8.89, 22.1791, 35.2130  	8.890000	8.580421	0.038606	0.009999	0.005000	0.060092	1.000000																							

$	13-Dec-2018	21:09:15.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.890000	145.154111	30.575000	369.000000																																

$	13-Dec-2018	21:09:16.075	Ascend	Vel PID Values																		0.050000	0.390000	0.388736	0.378770	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:16.075	Ascend	SBE41 Message						    8.50, 22.1793, 35.2145  	8.500000	8.774223	-0.030043	0.390000	0.200000	0.056213	1.000000																							

$	13-Dec-2018	21:09:16.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	8.500000	145.170473	30.575000	369.000000																																

$	13-Dec-2018	21:09:17.075	Ascend	Vel PID Values																		0.050000	0.940000	0.938168	0.549432	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:17.075	Ascend	SBE41 Message						    7.56, 22.1796, 35.2149  	7.560000	8.868972	-0.069970	0.940000	0.665000	0.051571	1.000000																							

$	13-Dec-2018	21:09:17.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22  Pres, BP, BatV, BatI: 	7.560000	145.143487	30.575000	369.000000																																

$	13-Dec-2018	21:09:18.123	Ascend	ERROR: Missed NO3 message 7

$	13-Dec-2018	21:09:18.226	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:09:18.232	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:09:18.834	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:09:18.851	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:09:18.953	Ascend	Sending FLBB run command

$	13-Dec-2018	21:09:19.054	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:09:19.160	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:09:19.262	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:09:19.475	Ascend	CTD post: 7.47	22.180	35.21

$	13-Dec-2018	21:09:18.073	Ascend	Vel PID Values																		0.050000	0.090000	0.092826	-0.845342	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:18.073	Ascend	SBE41 Message						    7.47, 22.1795, 35.2131  	7.470000	8.880512	-0.083937	0.090000	0.515000	0.046958	1.000000																							

$	13-Dec-2018	21:09:19.156	Ascend	Vel PID Values																		0.050000	0.000000	0.000304	-0.092521	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:19.156	Ascend	SBE41 Message						    7.47, 22.1795, 35.2152  	7.470000	8.812919	-0.081490	0.000000	0.045000	0.043306	1.000000																							

$	13-Dec-2018	21:09:20.254	Ascend	Radiometer Message																																	SATFI40287,-0.0046,0.0027,-0.0069,-0.2336 			

$	13-Dec-2018	21:09:20.369	Ascend	Radiometer post: SATFI40287,-0.0046,0.0027,-0.0069,-0.2336 

$	13-Dec-2018	21:09:19.926	Ascend	Optode Message																												4330,1532,265.420,22.467,29.137,29.068,36.119,7.051,530.8,463.3,111.4  								

$	13-Dec-2018	21:09:20.589	Ascend	Optode post: 4330,1532,265.420,22.467,29.137,29.068,36.119,7.051,530.8,463.3,111.4  

$	13-Dec-2018	21:09:20.894	Ascend	PTH Message														788.786133	23.650000	52.361053	24.536250																			

$	13-Dec-2018	21:09:21.097	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.470000	145.135634	30.925000	178.500000																																

$	13-Dec-2018	21:09:21.208	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0938504

$	13-Dec-2018	21:09:21.313	Ascend	Starting ISUS sample

$	13-Dec-2018	21:09:21.416	Ascend	Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00

$	13-Dec-2018	21:09:21.519	Ascend	MSC: OUT: W

$	13-Dec-2018	21:09:21.872	Ascend	MSC: OUT: W

$	13-Dec-2018	21:09:19.929	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:09:20.136	Ascend	Vel PID Values																		0.050000	0.000000	0.000001	-0.000304	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:20.136	Ascend	SBE41 Message						    7.47, 22.1806, 35.2150  	7.470000	8.620595	-0.060493	0.000000	0.000000	0.041560	1.000000																							

$	13-Dec-2018	21:09:22.341	Ascend	FLBB Message																											/99/99,99:99:99,695,2321,700,4130,532  									

$	13-Dec-2018	21:09:22.548	Ascend	FLBB post: /99/99,99:99:99,695,2321,700,4130,532  

$	13-Dec-2018	21:09:21.096	Ascend	Vel PID Values																		0.050000	0.040000	0.039867	0.039866	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:21.096	Ascend	SBE41 Message						    7.43, 22.1801, 35.2150  	7.430000	8.290991	-0.013637	0.040000	0.020000	0.042098	1.000000																							

$	13-Dec-2018	21:09:23.009	Ascend	MSC: RX: 

$	13-Dec-2018	21:09:23.013	Ascend	MSC: RX: 

$	13-Dec-2018	21:09:22.086	Ascend	Vel PID Values																		0.050000	0.070000	0.069900	0.030033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:22.086	Ascend	SBE41 Message						    7.36, 22.1802, 35.2157  	7.360000	7.919994	0.052708	0.070000	0.055000	0.044520	1.000000																							

$	13-Dec-2018	21:09:23.557	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:09:23.561	Ascend	MSC: Got ACK

$	13-Dec-2018	21:09:23.962	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.360000	145.142086	30.925000	178.500000																																

$	13-Dec-2018	21:09:24.074	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.8579093

$	13-Dec-2018	21:09:23.111	Ascend	Vel PID Values																		0.050000	0.070000	0.070000	0.000100	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:23.111	Ascend	SBE41 Message						    7.29, 22.1806, 35.2156  	7.290000	7.642945	0.115972	0.070000	0.070000	0.047980	1.000000																							

$	13-Dec-2018	21:09:24.072	Ascend	Vel PID Values																		0.050000	-0.430000	-0.428336	-0.498336	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:24.072	Ascend	SBE41 Message						    7.72, 22.1798, 35.2161  	7.720000	7.504957	0.157036	-0.430000	-0.180000	0.051747	1.000000																							

$	13-Dec-2018	21:09:25.066	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.720000	145.160824	30.925000	178.500000																																

$	13-Dec-2018	21:09:25.178	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0968097

$	13-Dec-2018	21:09:25.282	Ascend	MSC: OUT: CTD,0,0.0000,0.0000,0.0000

$	13-Dec-2018	21:09:25.175	Ascend	Vel PID Values																		0.050000	-0.460001	-0.459898	-0.031562	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:25.175	Ascend	SBE41 Message						    8.18, 22.1807, 35.2155  	8.180000	7.450632	0.175488	-0.460001	-0.445000	0.055293	1.000000																							

$	13-Dec-2018	21:09:25.942	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	8.180000	145.157658	30.925000	178.500000																																

$	13-Dec-2018	21:09:26.184	Ascend	MSC: RX: NAK,CTD,EConvertErr: 0 

$	13-Dec-2018	21:09:26.286	Ascend	MSC: EConvertErr: 0

$	13-Dec-2018	21:09:26.065	Ascend	Vel PID Values																		0.050000	0.020000	0.018403	0.478301	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:26.065	Ascend	SBE41 Message						    8.16, 22.1807, 35.2156  	8.160000	7.424571	0.180130	0.020000	-0.220000	0.058112	1.000000																							

$	13-Dec-2018	21:09:26.931	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	8.160000	145.161174	30.925000	178.500000																																

$	13-Dec-2018	21:09:27.063	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009903	-0.028306	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:27.063	Ascend	SBE41 Message						    8.17, 22.1804, 35.2156  	8.170000	7.439184	0.169937	-0.010000	0.005000	0.059581	1.000000																							

$	13-Dec-2018	21:09:27.727	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	8.170000	145.150915	30.925000	178.500000																																

$	13-Dec-2018	21:09:28.184	Ascend	MSC: OUT: W

$	13-Dec-2018	21:09:28.536	Ascend	MSC: OUT: W

$	13-Dec-2018	21:09:28.062	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009870	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:28.062	Ascend	SBE41 Message						    8.17, 22.1810, 35.2153  	8.170000	7.543817	0.133184	0.000000	-0.005000	0.059255	1.000000																							

$	13-Dec-2018	21:09:28.884	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:09:29.084	Ascend	MSC: Got ACK

$	13-Dec-2018	21:09:29.186	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:09:29.190	Ascend	MSC: Got ACK

$	13-Dec-2018	21:09:29.083	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:29.083	Ascend	SBE41 Message						    8.17, 22.1811, 35.2157  	8.170000	7.740314	0.068104	0.000000	0.000000	0.057137	1.000000																							

$	13-Dec-2018	21:09:29.935	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	8.170000	145.182982	30.925000	178.500000																																

$	13-Dec-2018	21:09:30.047	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8640451

$	13-Dec-2018	21:09:30.151	Ascend	MSC: OUT: MODE,1

$	13-Dec-2018	21:09:30.151	Ascend	Vel PID Values																		0.050000	0.000000	-0.000000	0.000000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:30.151	Ascend	SBE41 Message						    8.17, 22.1816, 35.2156  	8.170000	7.951615	-0.003917	0.000000	0.000000	0.053565	1.000000																							

$	13-Dec-2018	21:09:30.802	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	8.170000	145.161577	30.925000	178.500000																																

$	13-Dec-2018	21:09:31.053	Ascend	MSC: RX: ACK,MODE,1 

$	13-Dec-2018	21:09:31.155	Ascend	Vel PID Values																		0.050000	0.680000	0.677737	0.677737	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:31.155	Ascend	SBE41 Message						    7.49, 22.1817, 35.2158  	7.490000	8.094069	-0.055810	0.680000	0.340000	0.049304	1.000000																							

$	13-Dec-2018	21:09:31.702	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.490000	145.177275	30.925000	178.500000																																

$	13-Dec-2018	21:09:32.255	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.490000	145.161882	30.925000	178.500000																																

$	13-Dec-2018	21:09:33.053	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:09:32.059	Ascend	Vel PID Values																		0.050000	0.700000	0.699929	0.022192	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:32.059	Ascend	SBE41 Message						    6.79, 22.1821, 35.2157  	6.790000	8.151536	-0.080000	0.700000	0.690000	0.045311	1.000000																							

$	13-Dec-2018	21:09:33.155	Ascend	Vel PID Values																		0.050000	0.060000	0.062130	-0.637800	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:33.155	Ascend	SBE41 Message						    6.73, 22.1815, 35.2159  	6.730000	8.144617	-0.085875	0.060000	0.380000	0.042364	1.000000																							

$	13-Dec-2018	21:09:34.043	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.730000	145.165645	30.925000	178.500000																																

$	13-Dec-2018	21:09:34.159	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1073113

$	13-Dec-2018	21:09:34.157	Ascend	Vel PID Values																		0.050000	0.000000	0.000203	-0.061926	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:34.157	Ascend	SBE41 Message						    6.73, 22.1817, 35.2161  	6.730000	8.053842	-0.077871	0.000000	0.030000	0.040956	1.000000																							

$	13-Dec-2018	21:09:34.806	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.730000	145.157121	30.925000	178.500000																																

$	13-Dec-2018	21:09:35.165	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:09:35.057	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009966	-0.010169	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:35.057	Ascend	SBE41 Message						    6.74, 22.1823, 35.2155  	6.740000	7.826671	-0.047957	-0.010000	-0.005000	0.041228	1.000000																							

$	13-Dec-2018	21:09:35.818	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.740000	145.155363	30.925000	178.500000																																

$	13-Dec-2018	21:09:36.166	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:09:36.056	Ascend	Vel PID Values																		0.050000	0.050000	0.049800	0.059766	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:36.056	Ascend	SBE41 Message						    6.69, 22.1831, 35.2148  	6.690000	7.474543	0.008550	0.050000	0.020000	0.043078	1.000000																							

$	13-Dec-2018	21:09:36.812	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.690000	145.191461	30.925000	178.500000																																

$	13-Dec-2018	21:09:37.055	Ascend	Vel PID Values																		0.050000	0.060000	0.059966	0.010166	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:37.055	Ascend	SBE41 Message						    6.63, 22.1821, 35.2166  	6.630000	7.114434	0.077411	0.060000	0.055000	0.046202	1.000000																							

$	13-Dec-2018	21:09:37.710	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.630000	145.151846	30.925000	178.500000																																

$	13-Dec-2018	21:09:38.054	Ascend	Vel PID Values																		0.050000	0.080000	0.079933	0.019967	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:38.054	Ascend	SBE41 Message						    6.55, 22.1815, 35.2166  	6.550000	6.869101	0.133915	0.080000	0.070000	0.049999	1.000000																							

$	13-Dec-2018	21:09:38.710	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.550000	145.166263	30.925000	178.500000																																

$	13-Dec-2018	21:09:39.052	Ascend	Vel PID Values																		0.050000	-0.080000	-0.079468	-0.159401	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:39.052	Ascend	SBE41 Message						    6.63, 22.1822, 35.2163  	6.630000	6.756693	0.165463	-0.080000	0.000000	0.053655	1.000000																							

$	13-Dec-2018	21:09:39.711	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	6.630000	145.172372	30.925000	178.500000																																

$	13-Dec-2018	21:09:40.052	Ascend	Vel PID Values																		0.050000	-0.800000	-0.797603	-0.718135	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:40.052	Ascend	SBE41 Message						    7.43, 22.1825, 35.2156  	7.430000	6.711830	0.178131	-0.800000	-0.440000	0.056396	1.000000																							

$	13-Dec-2018	21:09:40.711	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.430000	145.177938	30.925000	178.500000																																

$	13-Dec-2018	21:09:41.050	Ascend	Vel PID Values																		0.050000	-0.050000	-0.052492	0.745111	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:41.050	Ascend	SBE41 Message						    7.48, 22.1823, 35.2140  	7.480000	6.679023	0.181318	-0.050000	-0.425000	0.057813	1.000000																							

$	13-Dec-2018	21:09:41.711	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.480000	145.161271	30.925000	178.500000																																

$	13-Dec-2018	21:09:42.050	Ascend	Vel PID Values																		0.050000	0.010000	0.009796	0.062288	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:42.050	Ascend	SBE41 Message						    7.47, 22.1821, 35.2161  	7.470000	6.665510	0.171732	0.010000	-0.020000	0.057929	1.000000																							

$	13-Dec-2018	21:09:42.416	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:09:42.818	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.470000	145.177536	30.925000	178.500000																																

$	13-Dec-2018	21:09:43.048	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009763	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:43.048	Ascend	SBE41 Message						    7.47, 22.1826, 35.2159  	7.470000	6.729424	0.135706	0.000000	0.005000	0.056843	1.000000																							

$	13-Dec-2018	21:09:43.716	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.470000	145.177037	30.925000	178.500000																																

$	13-Dec-2018	21:09:44.171	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:09:44.047	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:44.047	Ascend	SBE41 Message						    7.46, 22.1831, 35.2156  	7.460000	6.908807	0.069966	0.010000	0.005000	0.054529	1.000000																							

$	13-Dec-2018	21:09:45.010	Ascend	Error in I2CPortBase.Execute

$	13-Dec-2018	21:09:45.015	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.460000	145.177037	30.925000	178.500000																																

$	13-Dec-2018	21:09:45.223	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0527822

$	13-Dec-2018	21:09:45.531	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	7.460000	145.173535	30.925000	178.500000																																

$	13-Dec-2018	21:09:46.232	Ascend	MSC: RX: 0xFC41,A,02/01/2012 03:34:51,0,-1.00,-1.0000,-1.0000,255,163,1,66,22.75,54.41,11.576,5.248e-01,10660.00,2252.00,1170.87,13.38,-20432840AC3EE03DAE3D293D773EEE411A4429482D4D74533659E360D0679F6E5E73CD77BB79DD7A6C793B76AF73026EF86AA166CA637060D85F305E6F5E805FA5616363E9674A6B477006752D7B0B80FC86CB8C77917795B4987F99FB99DA97F994C490088A6183D37D6576DF709F6AFE65C361165D1859AE56DA545C527650DA4FAF4EEE4E924EB2,6726.2 

$	13-Dec-2018	21:09:46.341	Ascend	MSC: Data: 0xFC41,A,02/01/2012 03:34:51,0,-1.00,-1.0000,-1.0000,255,163,1,66,22.75,54.41,11.576,5.248e-01,10660.00,2252.00,1170.87,13.38,-20432840AC3EE03DAE3D293D773EEE411A4429482D4D74533659E360D0679F6E5E73CD77BB79DD7A6C793B76AF73026EF86AA166CA637060D85F305E6F5E805FA5616363E9674A6B477006752D7B0B80FC86CB8C77917795B4987F99FB99DA97F994C490088A6183D37D6576DF709F6AFE65C361165D1859AE56DA545C527650DA4FAF4EEE4E924EB2,6726.2 

$	13-Dec-2018	21:09:46.454	Ascend	MSC post: 6726.2

$	13-Dec-2018	21:09:45.398	Ascend	Vel PID Values																		0.050000	0.090000	0.089734	0.079767	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:45.398	Ascend	SBE41 Message						    7.37, 22.1831, 35.2160  	7.370000	7.150265	-0.004429	0.090000	0.050000	0.051140	1.000000																							

$	13-Dec-2018	21:09:46.045	Ascend	Vel PID Values																		0.050000	0.990000	0.987004	0.897270	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:46.045	Ascend	SBE41 Message						    6.38, 22.1840, 35.2154  	6.380000	7.345063	-0.058870	0.990000	0.540000	0.047686	1.000000																							

$	13-Dec-2018	21:09:47.126	Ascend	Vel PID Values																		0.050000	0.410000	0.411925	-0.575079	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:47.126	Ascend	SBE41 Message						    5.97, 22.1836, 35.2166  	5.970000	7.434416	-0.083844	0.410000	0.700000	0.044977	1.000000																							

$	13-Dec-2018	21:09:47.689	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23  Pres, BP, BatV, BatI: 	5.970000	145.156093	30.925000	178.500000																																

$	13-Dec-2018	21:09:47.800	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5692688

$	13-Dec-2018	21:09:47.805	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:09:48.004	Ascend	Starting pH sample

$	13-Dec-2018	21:09:48.008	Ascend	MSC: OUT: W

$	13-Dec-2018	21:09:48.363	Ascend	MSC: OUT: W

$	13-Dec-2018	21:09:48.476	Ascend	ERROR: Missed PH message 8

$	13-Dec-2018	21:09:48.580	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:09:48.584	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:09:49.186	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:09:49.203	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:09:49.305	Ascend	Sending FLBB run command

$	13-Dec-2018	21:09:49.504	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:09:49.511	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:09:49.615	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:09:49.828	Ascend	CTD post: 5.97	22.183	35.22

$	13-Dec-2018	21:09:48.107	Ascend	Vel PID Values																		0.050000	0.000000	0.001368	-0.410558	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:48.107	Ascend	SBE41 Message						    5.97, 22.1831, 35.2170  	5.970000	7.419373	-0.087554	0.000000	0.205000	0.043445	1.000000																							

$	13-Dec-2018	21:09:50.163	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:09:50.366	Ascend	MSC: Got ACK

$	13-Dec-2018	21:09:50.370	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:09:50.471	Ascend	MSC: Got ACK

$	13-Dec-2018	21:09:49.040	Ascend	Vel PID Values																		0.050000	0.000000	0.000002	-0.001365	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:49.040	Ascend	SBE41 Message						    5.97, 22.1837, 35.2166  	5.970000	7.281851	-0.074613	0.000000	0.000000	0.043100	1.000000																							

$	13-Dec-2018	21:09:50.916	Ascend	Radiometer Message																																	SATFI40287,-0.0046,0.0007,-0.0067,-0.2210 			

$	13-Dec-2018	21:09:51.129	Ascend	Radiometer post: SATFI40287,-0.0046,0.0007,-0.0067,-0.2210 

$	13-Dec-2018	21:09:51.434	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.970000	145.177029	30.925000	178.500000																																

$	13-Dec-2018	21:09:51.545	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.7394335

$	13-Dec-2018	21:09:51.650	Ascend	MSC: OUT: MODE,2

$	13-Dec-2018	21:09:50.146	Ascend	Vel PID Values																		0.050000	0.020000	0.019933	0.019931	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:50.146	Ascend	SBE41 Message						    5.95, 22.1837, 35.2165  	5.950000	6.990849	-0.040286	0.020000	0.010000	0.043994	1.000000																							

$	13-Dec-2018	21:09:50.365	Ascend	Optode Message																												4330,1532,265.422,22.478,29.133,29.064,36.115,7.052,530.7,463.2,111.1  								

$	13-Dec-2018	21:09:52.212	Ascend	Optode post: 4330,1532,265.422,22.478,29.133,29.064,36.115,7.052,530.7,463.2,111.1  

$	13-Dec-2018	21:09:50.365	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:09:52.427	Ascend	FLBB Message																											/99/99,99:99:99,695,2317,700,4130,532  									

$	13-Dec-2018	21:09:52.538	Ascend	FLBB post: /99/99,99:99:99,695,2317,700,4130,532  

$	13-Dec-2018	21:09:51.126	Ascend	Vel PID Values																		0.050000	0.050000	0.049900	0.029966	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:51.126	Ascend	SBE41 Message						    5.90, 22.1837, 35.2166  	5.900000	6.601439	0.015805	0.050000	0.035000	0.046275	1.000000																							

$	13-Dec-2018	21:09:53.186	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.900000	145.173632	30.925000	178.500000																																

$	13-Dec-2018	21:09:53.297	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7454448

$	13-Dec-2018	21:09:52.095	Ascend	Vel PID Values																		0.050000	0.050000	0.050000	0.000100	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:52.095	Ascend	SBE41 Message						    5.85, 22.1836, 35.2171  	5.850000	6.256366	0.080705	0.050000	0.050000	0.049618	1.000000																							

$	13-Dec-2018	21:09:53.743	Ascend	MSC: RX: ACK,MODE,2 

$	13-Dec-2018	21:09:53.037	Ascend	Vel PID Values																		0.050000	0.020000	0.020100	-0.029900	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:53.037	Ascend	SBE41 Message						    5.83, 22.1844, 35.2162  	5.830000	6.053260	0.135725	0.020000	0.035000	0.053170	1.000000																							

$	13-Dec-2018	21:09:54.392	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.830000	145.195685	30.925000	178.500000																																

$	13-Dec-2018	21:09:54.504	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1996075

$	13-Dec-2018	21:09:54.608	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:09:54.076	Ascend	Vel PID Values																		0.050000	-0.850000	-0.847105	-0.867204	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:54.076	Ascend	SBE41 Message						    6.68, 22.1841, 35.2159  	6.680000	5.969998	0.170138	-0.850000	-0.415000	0.055990	1.000000																							

$	13-Dec-2018	21:09:55.258	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	6.680000	145.164199	30.925000	178.500000																																

$	13-Dec-2018	21:09:55.056	Ascend	Vel PID Values																		0.050000	-0.060000	-0.062624	0.784481	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:55.056	Ascend	SBE41 Message						    6.74, 22.1842, 35.2160  	6.740000	5.935425	0.185466	-0.060000	-0.455000	0.057593	1.000000																							

$	13-Dec-2018	21:09:56.056	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	6.740000	145.169467	30.925000	178.500000																																

$	13-Dec-2018	21:09:56.512	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:09:56.034	Ascend	Vel PID Values																		0.050000	-0.020000	-0.020138	0.042486	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:56.034	Ascend	SBE41 Message						    6.76, 22.1847, 35.2160  	6.760000	5.926657	0.184667	-0.020000	-0.040000	0.057989	1.000000																							

$	13-Dec-2018	21:09:57.160	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	6.760000	145.193309	30.925000	178.500000																																

$	13-Dec-2018	21:09:57.513	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:09:57.033	Ascend	Vel PID Values																		0.050000	0.010000	0.009900	0.030038	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:57.033	Ascend	SBE41 Message						    6.75, 22.1848, 35.2159  	6.750000	5.987654	0.160084	0.010000	-0.005000	0.057263	1.000000																							

$	13-Dec-2018	21:09:58.159	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	6.750000	145.183131	30.925000	178.500000																																

$	13-Dec-2018	21:09:58.032	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009867	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:58.032	Ascend	SBE41 Message						    6.75, 22.1853, 35.2157  	6.750000	6.160537	0.102692	0.000000	0.005000	0.055318	1.000000																							

$	13-Dec-2018	21:09:59.058	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	6.750000	145.176314	30.925000	178.500000																																

$	13-Dec-2018	21:09:59.031	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:09:59.031	Ascend	SBE41 Message						    6.76, 22.1858, 35.2155  	6.760000	6.402578	0.024591	-0.010000	-0.005000	0.052228	1.000000																							

$	13-Dec-2018	21:10:00.059	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	6.760000	145.173356	30.925000	178.500000																																

$	13-Dec-2018	21:10:00.030	Ascend	Vel PID Values																		0.050000	0.770000	0.767405	0.777372	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:00.030	Ascend	SBE41 Message						    5.99, 22.1853, 35.2168  	5.990000	6.607611	-0.043451	0.770000	0.380000	0.048676	1.000000																							

$	13-Dec-2018	21:10:01.060	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.990000	145.162866	30.925000	178.500000																																

$	13-Dec-2018	21:10:01.027	Ascend	Vel PID Values																		0.050000	0.720000	0.720162	-0.047243	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:01.027	Ascend	SBE41 Message						    5.27, 22.1858, 35.2167  	5.270000	6.712520	-0.081562	0.720000	0.745000	0.045635	1.000000																							

$	13-Dec-2018	21:10:02.059	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.270000	145.161852	30.925000	178.500000																																

$	13-Dec-2018	21:10:02.028	Ascend	Vel PID Values																		0.050000	0.020000	0.022330	-0.697832	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:02.028	Ascend	SBE41 Message						    5.25, 22.1856, 35.2167  	5.250000	6.721714	-0.093016	0.020000	0.370000	0.043692	1.000000																							

$	13-Dec-2018	21:10:03.059	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.250000	145.175971	30.925000	178.500000																																

$	13-Dec-2018	21:10:03.029	Ascend	Vel PID Values																		0.050000	0.010000	0.010037	-0.012292	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:03.029	Ascend	SBE41 Message						    5.24, 22.1858, 35.2166  	5.240000	6.625332	-0.085381	0.010000	0.015000	0.042939	1.000000																							

$	13-Dec-2018	21:10:04.058	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.240000	145.203561	30.925000	178.500000																																

$	13-Dec-2018	21:10:04.027	Ascend	Vel PID Values																		0.050000	0.020000	0.019967	0.009929	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:04.027	Ascend	SBE41 Message						    5.22, 22.1858, 35.2169  	5.220000	6.379412	-0.056045	0.020000	0.015000	0.043435	1.000000																							

$	13-Dec-2018	21:10:05.058	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.220000	145.170219	30.925000	178.500000																																

$	13-Dec-2018	21:10:05.027	Ascend	Vel PID Values																		0.050000	0.030000	0.029966	0.010000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:05.027	Ascend	SBE41 Message						    5.19, 22.1859, 35.2167  	5.190000	6.003511	-0.001990	0.030000	0.025000	0.045280	1.000000																							

$	13-Dec-2018	21:10:06.059	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.190000	145.185150	30.925000	178.500000																																

$	13-Dec-2018	21:10:06.024	Ascend	Vel PID Values																		0.050000	0.060000	0.059900	0.029934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:06.024	Ascend	SBE41 Message						    5.13, 22.1862, 35.2169  	5.130000	5.625893	0.066126	0.060000	0.045000	0.048364	1.000000																							

$	13-Dec-2018	21:10:07.060	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.130000	145.186208	30.925000	178.500000																																

$	13-Dec-2018	21:10:07.517	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:10:07.023	Ascend	Vel PID Values																		0.050000	0.040000	0.040066	-0.019834	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:07.023	Ascend	SBE41 Message						    5.09, 22.1862, 35.2173  	5.090000	5.373120	0.127359	0.040000	0.050000	0.051983	1.000000																							

$	13-Dec-2018	21:10:08.164	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.090000	145.171314	30.925000	178.500000																																

$	13-Dec-2018	21:10:08.024	Ascend	Vel PID Values																		0.050000	-0.610000	-0.607836	-0.647903	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:08.024	Ascend	SBE41 Message						    5.70, 22.1871, 35.2164  	5.700000	5.257748	0.167015	-0.610000	-0.285000	0.055234	1.000000																							

$	13-Dec-2018	21:10:09.063	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.700000	145.178966	30.925000	178.500000																																

$	13-Dec-2018	21:10:09.517	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:10:09.022	Ascend	Vel PID Values																		0.050000	-0.180000	-0.181428	0.426409	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:09.022	Ascend	SBE41 Message						    5.88, 22.1866, 35.2170  	5.880000	5.212830	0.185555	-0.180000	-0.395000	0.057456	1.000000																							

$	13-Dec-2018	21:10:10.190	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.880000	145.187564	30.925000	178.500000																																

$	13-Dec-2018	21:10:10.519	Ascend	MSC: RX: 0xAD8C,pH,02/01/2012 03:35:18,0,-1.00,-1.0000,-1.0000,280,163,0,22.76,54.38,11.744,4.620e-02,7.1234,0.000,-0.972736,0.000640,-0.

$	13-Dec-2018	21:10:10.524	Ascend	MSC: Data: 0xAD8C,pH,02/01/2012 03:35:18,0,-1.00,-1.0000,-1.0000,280,163,0,22.76,54.38,11.744,4.620e-02,7.1234,0.000,-0.972736,0.000640,-0.

$	13-Dec-2018	21:10:10.728	Ascend	MSC post: 7.1234

$	13-Dec-2018	21:10:10.056	Ascend	Vel PID Values																		0.050000	0.020000	0.019332	0.200760	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:10.056	Ascend	SBE41 Message						    5.86, 22.1873, 35.2165  	5.860000	5.196353	0.188714	0.020000	-0.080000	0.058428	1.000000																							

$	13-Dec-2018	21:10:11.056	Ascend	Vel PID Values																		0.050000	0.030000	0.029966	0.010634	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:11.056	Ascend	SBE41 Message						    5.83, 22.1871, 35.2171  	5.830000	5.231793	0.172380	0.030000	0.025000	0.058201	1.000000																							

$	13-Dec-2018	21:10:11.716	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.830000	145.187616	30.925000	178.500000																																

$	13-Dec-2018	21:10:11.827	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3096576

$	13-Dec-2018	21:10:11.835	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:10:12.034	Ascend	MSC: OUT: SLP

$	13-Dec-2018	21:10:12.034	Ascend	Vel PID Values																		0.050000	0.000000	0.000100	-0.029866	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:12.034	Ascend	SBE41 Message						    5.83, 22.1872, 35.2168  	5.830000	5.357382	0.126407	0.000000	0.015000	0.056772	1.000000																							

$	13-Dec-2018	21:10:12.683	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.830000	145.183325	30.925000	178.500000																																

$	13-Dec-2018	21:10:12.834	Ascend	MSC: RX: ACK,SLP 

$	13-Dec-2018	21:10:13.138	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.830000	145.177931	30.925000	178.500000																																

$	13-Dec-2018	21:10:13.017	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009867	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:13.017	Ascend	SBE41 Message						    5.82, 22.1874, 35.2167  	5.820000	5.549018	0.056204	0.010000	0.005000	0.054133	1.000000																							

$	13-Dec-2018	21:10:14.065	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009933	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:14.065	Ascend	SBE41 Message						    5.82, 22.1876, 35.2168  	5.820000	5.721014	-0.011775	0.000000	0.005000	0.050715	1.000000																							

$	13-Dec-2018	21:10:14.725	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.820000	145.179704	30.925000	178.500000																																

$	13-Dec-2018	21:10:14.836	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0020281

$	13-Dec-2018	21:10:15.141	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.820000	145.195879	30.925000	178.500000																																

$	13-Dec-2018	21:10:15.015	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:15.015	Ascend	SBE41 Message						    5.81, 22.1872, 35.2171  	5.810000	5.812349	-0.054345	0.010000	0.005000	0.047421	1.000000																							

$	13-Dec-2018	21:10:16.072	Ascend	Vel PID Values																		0.050000	0.510000	0.508336	0.498369	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:16.072	Ascend	SBE41 Message						    5.30, 22.1880, 35.2171  	5.300000	5.834728	-0.071395	0.510000	0.260000	0.045010	1.000000																							

$	13-Dec-2018	21:10:16.731	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.300000	145.177171	30.925000	178.500000																																

$	13-Dec-2018	21:10:16.842	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0002928

$	13-Dec-2018	21:10:17.147	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	5.300000	145.180859	30.925000	178.500000																																

$	13-Dec-2018	21:10:17.013	Ascend	Vel PID Values																		0.050000	0.740000	0.739232	0.230896	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:17.013	Ascend	SBE41 Message						    4.56, 22.1879, 35.2170  	4.560000	5.828789	-0.076220	0.740000	0.625000	0.043716	1.000000																							

$	13-Dec-2018	21:10:18.076	Ascend	Vel PID Values																		0.050000	0.060000	0.062262	-0.676971	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:18.076	Ascend	SBE41 Message						    4.50, 22.1880, 35.2176  	4.500000	5.805131	-0.075321	0.060000	0.400000	0.043199	1.000000																							

$	13-Dec-2018	21:10:18.734	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.500000	145.171851	30.925000	178.500000																																

$	13-Dec-2018	21:10:19.049	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.500000	145.163059	30.925000	178.500000																																

$	13-Dec-2018	21:10:19.011	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009764	-0.072025	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:19.011	Ascend	SBE41 Message						    4.51, 22.1881, 35.2179  	4.510000	5.724207	-0.060913	-0.010000	0.025000	0.043228	1.000000																							

$	13-Dec-2018	21:10:20.076	Ascend	Vel PID Values																		0.050000	0.020000	0.019901	0.029665	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:20.076	Ascend	SBE41 Message						    4.49, 22.1887, 35.2167  	4.490000	5.526303	-0.020896	0.020000	0.005000	0.043949	1.000000																							

$	13-Dec-2018	21:10:20.736	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.490000	145.175420	30.925000	178.500000																																

$	13-Dec-2018	21:10:21.049	Ascend	PTH Message														788.924805	23.591667	52.444977	24.525525																			

$	13-Dec-2018	21:10:21.252	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.490000	145.187140	51.175000	152.500000																																

$	13-Dec-2018	21:10:21.009	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	0.000099	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:21.009	Ascend	SBE41 Message						    4.47, 22.1892, 35.2170  	4.470000	5.210593	0.041849	0.020000	0.020000	0.045744	1.000000																							

$	13-Dec-2018	21:10:22.076	Ascend	Vel PID Values																		0.050000	0.040000	0.039933	0.019934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:22.076	Ascend	SBE41 Message						    4.43, 22.1895, 35.2162  	4.430000	4.876199	0.104483	0.040000	0.030000	0.048534	1.000000																							

$	13-Dec-2018	21:10:22.735	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.430000	145.186245	51.175000	152.500000																																

$	13-Dec-2018	21:10:22.848	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0006269

$	13-Dec-2018	21:10:23.153	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.430000	145.177424	51.175000	152.500000																																

$	13-Dec-2018	21:10:23.007	Ascend	Vel PID Values																		0.050000	0.040000	0.040000	0.000066	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:23.007	Ascend	SBE41 Message						    4.39, 22.1895, 35.2170  	4.390000	4.639811	0.145036	0.040000	0.040000	0.051618	1.000000																							

$	13-Dec-2018	21:10:24.082	Ascend	Vel PID Values																		0.050000	0.060000	0.059933	0.019934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:24.082	Ascend	SBE41 Message						    4.33, 22.1893, 35.2170  	4.330000	4.527921	0.161671	0.060000	0.050000	0.054018	1.000000																							

$	13-Dec-2018	21:10:24.742	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.330000	145.190142	51.175000	152.500000																																

$	13-Dec-2018	21:10:24.855	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0019655

$	13-Dec-2018	21:10:25.161	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.330000	145.197660	51.175000	152.500000																																

$	13-Dec-2018	21:10:25.006	Ascend	Vel PID Values																		0.050000	-0.110000	-0.109435	-0.169368	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:25.006	Ascend	SBE41 Message						    4.44, 22.1892, 35.2179  	4.440000	4.485743	0.166169	-0.110000	-0.025000	0.055131	1.000000																							

$	13-Dec-2018	21:10:26.090	Ascend	Vel PID Values																		0.050000	-0.500000	-0.498701	-0.389267	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:26.090	Ascend	SBE41 Message						    4.94, 22.1895, 35.2171  	4.940000	4.458382	0.166617	-0.500000	-0.305000	0.055145	1.000000																							

$	13-Dec-2018	21:10:26.751	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.940000	145.190142	51.175000	152.500000																																

$	13-Dec-2018	21:10:26.862	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0017408

$	13-Dec-2018	21:10:27.167	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.940000	145.183519	51.175000	152.500000																																

$	13-Dec-2018	21:10:27.003	Ascend	Vel PID Values																		0.050000	0.000000	-0.001662	0.497040	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:27.003	Ascend	SBE41 Message						    4.94, 22.1901, 35.2170  	4.940000	4.429977	0.160093	0.000000	-0.250000	0.054379	1.000000																							

$	13-Dec-2018	21:10:28.095	Ascend	Vel PID Values																		0.050000	0.030000	0.029898	0.031559	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:28.095	Ascend	SBE41 Message						    4.91, 22.1897, 35.2173  	4.910000	4.419773	0.136851	0.030000	0.015000	0.053133	1.000000																							

$	13-Dec-2018	21:10:28.755	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.910000	145.179100	51.175000	152.500000																																

$	13-Dec-2018	21:10:29.069	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.910000	145.177513	51.175000	152.500000																																

$	13-Dec-2018	21:10:29.000	Ascend	Vel PID Values																		0.050000	0.010000	0.010066	-0.019831	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:29.000	Ascend	SBE41 Message						    4.90, 22.1905, 35.2169  	4.900000	4.466987	0.091957	0.010000	0.020000	0.051701	1.000000																							

$	13-Dec-2018	21:10:30.096	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	-0.000066	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:30.096	Ascend	SBE41 Message						    4.89, 22.1902, 35.2174  	4.890000	4.589058	0.035511	0.010000	0.010000	0.050384	1.000000																							

$	13-Dec-2018	21:10:30.756	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.890000	145.180725	51.175000	152.500000																																

$	13-Dec-2018	21:10:31.071	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.890000	145.186961	51.175000	152.500000																																

$	13-Dec-2018	21:10:30.999	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009967	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:30.999	Ascend	SBE41 Message						    4.89, 22.1902, 35.2168  	4.890000	4.742348	-0.012676	0.000000	0.005000	0.049572	1.000000																							

$	13-Dec-2018	21:10:32.096	Ascend	Vel PID Values																		0.050000	0.000000	0.000000	-0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:32.096	Ascend	SBE41 Message						    4.89, 22.1909, 35.2167  	4.890000	4.855203	-0.040479	0.000000	0.000000	0.049304	1.000000																							

$	13-Dec-2018	21:10:32.756	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.890000	145.195782	51.175000	152.500000																																

$	13-Dec-2018	21:10:33.070	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.890000	145.206422	51.175000	152.500000																																

$	13-Dec-2018	21:10:32.995	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.009967	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:32.995	Ascend	SBE41 Message						    4.90, 22.1904, 35.2176  	4.900000	4.899920	-0.051242	-0.010000	-0.005000	0.049429	1.000000																							

$	13-Dec-2018	21:10:34.096	Ascend	Vel PID Values																		0.050000	0.480000	0.478369	0.488336	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:34.096	Ascend	SBE41 Message						    4.42, 22.1905, 35.2179  	4.420000	4.902682	-0.054980	0.480000	0.235000	0.049611	1.000000																							

$	13-Dec-2018	21:10:34.756	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.420000	145.195141	51.175000	152.500000																																

$	13-Dec-2018	21:10:35.070	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	4.420000	145.210572	51.175000	152.500000																																

$	13-Dec-2018	21:10:34.995	Ascend	Vel PID Values																		0.050000	0.740000	0.739132	0.260763	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:34.995	Ascend	SBE41 Message						    3.68, 22.1910, 35.2174  	3.680000	4.894784	-0.057515	0.740000	0.610000	0.049787	1.000000																							

$	13-Dec-2018	21:10:36.096	Ascend	Vel PID Values																		0.050000	0.100000	0.102128	-0.637004	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:36.096	Ascend	SBE41 Message						    3.58, 22.1909, 35.2181  	3.580000	4.876018	-0.056444	0.100000	0.420000	0.049849	1.000000																							

$	13-Dec-2018	21:10:36.757	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24  Pres, BP, BatV, BatI: 	3.580000	145.198137	51.175000	152.500000																																

$	13-Dec-2018	21:10:36.868	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0002196

$	13-Dec-2018	21:10:36.979	Ascend	ERROR: Missed NO3 message 8

$	13-Dec-2018	21:10:37.085	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:10:37.089	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:10:37.788	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:10:37.805	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:10:37.907	Ascend	Sending FLBB run command

$	13-Dec-2018	21:10:38.009	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:10:38.114	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:10:38.216	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:10:38.430	Ascend	CTD post: 3.58	22.191	35.22

$	13-Dec-2018	21:10:37.083	Ascend	Vel PID Values																		0.050000	0.000000	0.000336	-0.101792	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:37.083	Ascend	SBE41 Message						    3.58, 22.1907, 35.2179  	3.580000	4.804301	-0.041722	0.000000	0.050000	0.049746	1.000000																							

$	13-Dec-2018	21:10:38.006	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009631	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:38.006	Ascend	SBE41 Message						    3.57, 22.1908, 35.2176  	3.570000	4.618345	-0.003625	0.010000	0.005000	0.049456	1.000000																							

$	13-Dec-2018	21:10:39.109	Ascend	Radiometer Message																																	SATFI40287,-0.0057,0.0026,-0.0067,-0.2250 			

$	13-Dec-2018	21:10:39.324	Ascend	Radiometer post: SATFI40287,-0.0057,0.0026,-0.0067,-0.2250 

$	13-Dec-2018	21:10:38.880	Ascend	Optode Message																												4330,1532,265.327,22.484,29.135,29.065,36.116,7.051,530.6,463.1,110.9  								

$	13-Dec-2018	21:10:39.543	Ascend	Optode post: 4330,1532,265.327,22.484,29.135,29.065,36.116,7.051,530.6,463.1,110.9  

$	13-Dec-2018	21:10:38.882	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:10:39.960	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.570000	145.189129	51.175000	152.500000																																

$	13-Dec-2018	21:10:40.072	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1989003

$	13-Dec-2018	21:10:40.176	Ascend	Starting ISUS sample

$	13-Dec-2018	21:10:40.279	Ascend	Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00

$	13-Dec-2018	21:10:40.285	Ascend	MSC: OUT: W

$	13-Dec-2018	21:10:40.735	Ascend	MSC: OUT: W

$	13-Dec-2018	21:10:39.093	Ascend	Vel PID Values																		0.050000	0.030000	0.029933	0.019966	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:39.093	Ascend	SBE41 Message						    3.54, 22.1909, 35.2180  	3.540000	4.311197	0.053314	0.030000	0.020000	0.049053	1.000000																							

$	13-Dec-2018	21:10:41.181	Ascend	FLBB Message																											/99/99,99:99:99,695,2318,700,4130,532  									

$	13-Dec-2018	21:10:41.292	Ascend	FLBB post: /99/99,99:99:99,695,2318,700,4130,532  

$	13-Dec-2018	21:10:40.071	Ascend	Vel PID Values																		0.050000	0.020000	0.020033	-0.009900	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:40.071	Ascend	SBE41 Message						    3.52, 22.1910, 35.2175  	3.520000	3.975936	0.108738	0.020000	0.025000	0.048700	1.000000																							

$	13-Dec-2018	21:10:41.738	Ascend	MSC: RX: 

$	13-Dec-2018	21:10:41.742	Ascend	MSC: RX: 

$	13-Dec-2018	21:10:41.066	Ascend	Vel PID Values																		0.050000	0.040000	0.039933	0.019900	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:41.066	Ascend	SBE41 Message						    3.48, 22.1910, 35.2178  	3.480000	3.730744	0.144616	0.040000	0.030000	0.048349	1.000000																							

$	13-Dec-2018	21:10:42.286	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:10:42.290	Ascend	MSC: Got ACK

$	13-Dec-2018	21:10:42.594	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.480000	145.192966	51.175000	152.500000																																

$	13-Dec-2018	21:10:42.705	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.6261062

$	13-Dec-2018	21:10:41.988	Ascend	Vel PID Values																		0.050000	0.040000	0.040000	0.000066	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:41.988	Ascend	SBE41 Message						    3.44, 22.1913, 35.2183  	3.440000	3.609796	0.159947	0.040000	0.040000	0.047851	1.000000																							

$	13-Dec-2018	21:10:43.358	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.440000	145.187713	51.175000	152.500000																																

$	13-Dec-2018	21:10:43.712	Ascend	MSC: OUT: CTD,0,0.0000,0.0000,0.0000

$	13-Dec-2018	21:10:43.042	Ascend	Vel PID Values																		0.050000	-0.250000	-0.249035	-0.289035	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:43.042	Ascend	SBE41 Message						    3.69, 22.1915, 35.2181  	3.690000	3.563994	0.164652	-0.250000	-0.105000	0.047304	1.000000																							

$	13-Dec-2018	21:10:44.054	Ascend	Vel PID Values																		0.050000	-0.350000	-0.349666	-0.100631	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:44.054	Ascend	SBE41 Message						    4.04, 22.1915, 35.2180  	4.040000	3.539265	0.165382	-0.350000	-0.300000	0.047217	1.000000																							

$	13-Dec-2018	21:10:44.511	Ascend	MSC: RX: NAK,CTD,EConvertErr: 0 

$	13-Dec-2018	21:10:44.613	Ascend	MSC: EConvertErr: 0

$	13-Dec-2018	21:10:44.917	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	4.040000	145.183839	51.175000	152.500000																																

$	13-Dec-2018	21:10:45.029	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3190467

$	13-Dec-2018	21:10:45.028	Ascend	Vel PID Values																		0.050000	0.020000	0.018769	0.368435	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:45.028	Ascend	SBE41 Message						    4.02, 22.1914, 35.2154  	4.020000	3.520557	0.158799	0.020000	-0.165000	0.048115	1.000000																							

$	13-Dec-2018	21:10:45.678	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	4.020000	145.210706	51.175000	152.500000																																

$	13-Dec-2018	21:10:46.134	Ascend	MSC: OUT: W

$	13-Dec-2018	21:10:46.486	Ascend	MSC: OUT: W

$	13-Dec-2018	21:10:45.985	Ascend	Vel PID Values																		0.050000	0.020000	0.019998	0.001229	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:45.985	Ascend	SBE41 Message						    4.00, 22.1913, 35.2178  	4.000000	3.529097	0.134717	0.020000	0.020000	0.049975	1.000000																							

$	13-Dec-2018	21:10:46.929	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:10:46.935	Ascend	MSC: Got ACK

$	13-Dec-2018	21:10:47.135	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:10:47.140	Ascend	MSC: Got ACK

$	13-Dec-2018	21:10:47.033	Ascend	Vel PID Values																		0.050000	0.010000	0.010033	-0.009965	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:47.033	Ascend	SBE41 Message						    3.99, 22.1916, 35.2181  	3.990000	3.598274	0.088163	0.010000	0.015000	0.052157	1.000000																							

$	13-Dec-2018	21:10:47.884	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.990000	145.203955	51.175000	152.500000																																

$	13-Dec-2018	21:10:47.996	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8625524

$	13-Dec-2018	21:10:48.099	Ascend	MSC: OUT: MODE,1

$	13-Dec-2018	21:10:47.994	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	-0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:47.994	Ascend	SBE41 Message						    3.98, 22.1928, 35.2173  	3.980000	3.729408	0.030486	0.010000	0.010000	0.053979	1.000000																							

$	13-Dec-2018	21:10:48.749	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.980000	145.184278	51.175000	152.500000																																

$	13-Dec-2018	21:10:49.002	Ascend	MSC: RX: ACK,MODE,1 

$	13-Dec-2018	21:10:48.981	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009933	-0.019933	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:48.981	Ascend	SBE41 Message						    3.99, 22.1915, 35.2182  	3.990000	3.870560	-0.017292	-0.010000	0.000000	0.055178	1.000000																							

$	13-Dec-2018	21:10:49.649	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.990000	145.202450	51.175000	152.500000																																

$	13-Dec-2018	21:10:49.980	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019867	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:49.980	Ascend	SBE41 Message						    3.98, 22.1918, 35.2173  	3.980000	3.962329	-0.043608	0.010000	0.000000	0.055843	1.000000																							

$	13-Dec-2018	21:10:50.547	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.980000	145.181492	51.175000	152.500000																																

$	13-Dec-2018	21:10:51.002	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:10:50.979	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009934	-0.019867	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:50.979	Ascend	SBE41 Message						    3.99, 22.1919, 35.2181  	3.990000	3.993621	-0.053157	-0.010000	0.000000	0.056025	1.000000																							

$	13-Dec-2018	21:10:51.651	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.990000	145.188376	51.175000	152.500000																																

$	13-Dec-2018	21:10:51.978	Ascend	Vel PID Values																		0.050000	0.420000	0.418569	0.428503	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:51.978	Ascend	SBE41 Message						    3.57, 22.1923, 35.2178  	3.570000	3.993437	-0.056200	0.420000	0.205000	0.055497	1.000000																							

$	13-Dec-2018	21:10:52.547	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.570000	145.216435	51.175000	152.500000																																

$	13-Dec-2018	21:10:53.002	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:10:52.976	Ascend	Vel PID Values																		0.050000	0.750000	0.748899	0.330330	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:52.976	Ascend	SBE41 Message						    2.82, 22.1926, 35.2178  	2.820000	3.986930	-0.057705	0.750000	0.585000	0.054001	1.000000																							

$	13-Dec-2018	21:10:53.650	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.820000	145.190232	51.175000	152.500000																																

$	13-Dec-2018	21:10:54.002	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:10:53.975	Ascend	Vel PID Values																		0.050000	0.130000	0.132061	-0.616838	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:53.975	Ascend	SBE41 Message						    2.69, 22.1921, 35.2184  	2.690000	3.970629	-0.054619	0.130000	0.440000	0.051596	1.000000																							

$	13-Dec-2018	21:10:54.650	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.690000	145.211421	51.175000	152.500000																																

$	13-Dec-2018	21:10:54.974	Ascend	Vel PID Values																		0.050000	0.010000	0.010403	-0.121658	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:54.974	Ascend	SBE41 Message						    2.68, 22.1926, 35.2180  	2.680000	3.904405	-0.037863	0.010000	0.070000	0.048758	1.000000																							

$	13-Dec-2018	21:10:55.546	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.680000	145.210378	51.175000	152.500000																																

$	13-Dec-2018	21:10:55.973	Ascend	Vel PID Values																		0.050000	0.000000	0.000034	-0.010369	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:55.973	Ascend	SBE41 Message						    2.68, 22.1920, 35.2188  	2.680000	3.728665	0.000089	0.000000	0.005000	0.046109	1.000000																							

$	13-Dec-2018	21:10:56.546	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.680000	145.201929	51.175000	152.500000																																

$	13-Dec-2018	21:10:56.972	Ascend	Vel PID Values																		0.050000	0.030000	0.029900	0.029866	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:56.972	Ascend	SBE41 Message						    2.65, 22.1921, 35.2187  	2.650000	3.431858	0.054246	0.030000	0.015000	0.044178	1.000000																							

$	13-Dec-2018	21:10:57.546	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.650000	145.183243	51.175000	152.500000																																

$	13-Dec-2018	21:10:57.971	Ascend	Vel PID Values																		0.050000	0.020000	0.020033	-0.009867	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:57.971	Ascend	SBE41 Message						    2.63, 22.1923, 35.2189  	2.630000	3.099411	0.106714	0.020000	0.025000	0.043100	1.000000																							

$	13-Dec-2018	21:10:58.547	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.630000	145.186864	51.175000	152.500000																																

$	13-Dec-2018	21:10:58.971	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	-0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:58.971	Ascend	SBE41 Message						    2.61, 22.1925, 35.2184  	2.610000	2.848836	0.141597	0.020000	0.020000	0.042745	1.000000																							

$	13-Dec-2018	21:10:59.547	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.610000	145.189524	51.175000	152.500000																																

$	13-Dec-2018	21:10:59.969	Ascend	Vel PID Values																		0.050000	0.040000	0.039933	0.019933	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:10:59.969	Ascend	SBE41 Message						    2.57, 22.1926, 35.2185  	2.570000	2.721331	0.157374	0.040000	0.030000	0.043078	1.000000																							

$	13-Dec-2018	21:11:00.344	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:11:00.649	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.570000	145.183131	51.175000	152.500000																																

$	13-Dec-2018	21:11:00.969	Ascend	Vel PID Values																		0.050000	0.030000	0.030033	-0.009900	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:00.969	Ascend	SBE41 Message						    2.54, 22.1930, 35.2182  	2.540000	2.673358	0.162521	0.030000	0.035000	0.044284	1.000000																							

$	13-Dec-2018	21:11:01.547	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.540000	145.215616	51.175000	152.500000																																

$	13-Dec-2018	21:11:02.004	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:11:01.968	Ascend	Vel PID Values																		0.050000	-0.350000	-0.348736	-0.378769	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:01.968	Ascend	SBE41 Message						    2.89, 22.1935, 35.2184  	2.890000	2.650216	0.163362	-0.350000	-0.160000	0.046379	1.000000																							

$	13-Dec-2018	21:11:03.649	Ascend	Error executing 2485 Transaction = 0

$	13-Dec-2018	21:11:03.752	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.890000	250.000000	51.175000	152.500000																																

$	13-Dec-2018	21:11:03.864	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8602453

$	13-Dec-2018	21:11:03.969	Ascend	MSC: RX: 0xA471,A,02/01/2012 03:36:09,0,-1.00,-1.0000,-1.0000,256,163,1,66,22.85,54.27,11.576,5.248e-01,10665.00,2268.00,1174.01,12.95,-2BA4319409A3ED03D9C3D113D743EFC410D442148234D3D531C59C460A567966E18739E779E79AD7A55794076AD72E76EC36A7666B6638060D15F375E655E695F93613363D067276B186FE3750C7AF780D386A58C52914B9582986E99F999BD97CF933497E8787F9DE6789AA2DF778A35B50779D430A77666ABD97720EA7C66EACCF3366A57C6B6661BB061653D81026509DBA56EB5465526550C64FB84EE44E9E4EA6,6702.2 

$	13-Dec-2018	21:11:03.981	Ascend	MSC: Data: 0xA471,A,02/01/2012 03:36:09,0,-1.00,-1.0000,-1.0000,256,163,1,66,22.85,54.27,11.576,5.248e-01,10665.00,2268.00,1174.01,12.95,-2BA4319409A3ED03D9C3D113D743EFC410D442148234D3D531C59C460A567966E18739E779E79AD7A55794076AD72E76EC36A7666B6638060D15F375E655E695F93613363D067276B186FE3750C7AF780D386A58C52914B9582986E99F999BD97CF933497E8787F9DE6789AA2DF778A35B50779D430A77666ABD97720EA7C66EACCF3366A57C6B6661BB061653D81026509DBA56EB5465526550C64FB84EE44E9E4EA6,6702.2 

$	13-Dec-2018	21:11:04.193	Ascend	MSC post: 6702.2

$	13-Dec-2018	21:11:02.967	Ascend	Vel PID Values																		0.050000	-0.200000	-0.200497	0.148239	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:02.967	Ascend	SBE41 Message						    3.09, 22.1934, 35.2184  	3.090000	2.628757	0.157799	-0.200000	-0.275000	0.049061	1.000000																							

$	13-Dec-2018	21:11:03.967	Ascend	Vel PID Values																		0.050000	0.030000	0.029234	0.229731	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:03.967	Ascend	SBE41 Message						    3.06, 22.1940, 35.2182  	3.060000	2.613848	0.137879	0.030000	-0.085000	0.051834	1.000000																							

$	13-Dec-2018	21:11:04.979	Ascend	Vel PID Values																		0.050000	0.020000	0.020032	-0.009202	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:04.979	Ascend	SBE41 Message						    3.04, 22.1946, 35.2174  	3.040000	2.631554	0.098967	0.020000	0.025000	0.054362	1.000000																							

$	13-Dec-2018	21:11:05.427	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.040000	145.196632	51.175000	152.500000																																

$	13-Dec-2018	21:11:05.538	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6692281

$	13-Dec-2018	21:11:05.643	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:11:05.647	Ascend	Starting pH sample

$	13-Dec-2018	21:11:05.846	Ascend	MSC: OUT: W

$	13-Dec-2018	21:11:06.101	Ascend	MSC: OUT: W

$	13-Dec-2018	21:11:05.963	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009900	-0.029932	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:05.963	Ascend	SBE41 Message						    3.05, 22.1946, 35.2179  	3.050000	2.709609	0.048203	-0.010000	0.005000	0.056338	1.000000																							

$	13-Dec-2018	21:11:06.546	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:11:06.550	Ascend	MSC: Got ACK

$	13-Dec-2018	21:11:06.953	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.050000	145.199023	51.175000	152.500000																																

$	13-Dec-2018	21:11:07.064	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5192277

$	13-Dec-2018	21:11:07.169	Ascend	MSC: OUT: MODE,2

$	13-Dec-2018	21:11:07.274	Ascend	MSC: RX: ACK 

$	13-Dec-2018	21:11:07.375	Ascend	MSC: Got ACK

$	13-Dec-2018	21:11:07.063	Ascend	Vel PID Values																		0.050000	0.020000	0.019900	0.029800	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:07.063	Ascend	SBE41 Message						    3.03, 22.1949, 35.2183  	3.030000	2.836723	0.001501	0.020000	0.005000	0.057629	1.000000																							

$	13-Dec-2018	21:11:07.840	Ascend	MSC: RX: ACK,MODE,2 

$	13-Dec-2018	21:11:08.147	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.030000	145.189263	51.175000	152.500000																																

$	13-Dec-2018	21:11:08.258	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1870136

$	13-Dec-2018	21:11:07.963	Ascend	Vel PID Values																		0.050000	-0.020000	-0.019867	-0.039767	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:07.963	Ascend	SBE41 Message						    3.05, 22.1942, 35.2188  	3.050000	2.957419	-0.029196	-0.020000	0.000000	0.058212	1.000000																							

$	13-Dec-2018	21:11:08.907	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.050000	145.184629	51.175000	152.500000																																

$	13-Dec-2018	21:11:09.264	Ascend	MSC: OUT: ACK

$	13-Dec-2018	21:11:09.017	Ascend	Vel PID Values																		0.050000	0.020000	0.019867	0.039734	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:09.017	Ascend	SBE41 Message						    3.03, 22.1947, 35.2187  	3.030000	3.025982	-0.043620	0.020000	0.000000	0.058097	1.000000																							

$	13-Dec-2018	21:11:09.912	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.030000	145.210318	51.175000	152.500000																																

$	13-Dec-2018	21:11:10.022	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	0.000133	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:10.022	Ascend	SBE41 Message						    3.01, 22.1945, 35.2190  	3.010000	3.045476	-0.048907	0.020000	0.020000	0.057140	1.000000																							

$	13-Dec-2018	21:11:10.810	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	3.010000	145.192638	51.175000	152.500000																																

$	13-Dec-2018	21:11:11.264	Ascend	MSC: OUT: TS

$	13-Dec-2018	21:11:10.959	Ascend	Vel PID Values																		0.050000	0.650000	0.647904	0.627904	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:10.959	Ascend	SBE41 Message						    2.36, 22.1948, 35.2190  	2.360000	3.044370	-0.051429	0.650000	0.335000	0.055347	1.000000																							

$	13-Dec-2018	21:11:11.914	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	2.360000	145.211674	51.175000	152.500000																																

$	13-Dec-2018	21:11:12.265	Ascend	MSC: RX: ACK,TS,CMD 

$	13-Dec-2018	21:11:12.025	Ascend	Vel PID Values																		0.050000	0.530000	0.530396	-0.117508	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:12.025	Ascend	SBE41 Message						    1.83, 22.1949, 35.2193  	1.830000	3.038404	-0.052528	0.530000	0.590000	0.052784	1.000000																							

$	13-Dec-2018	21:11:12.911	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25  Pres, BP, BatV, BatI: 	1.830000	145.216599	51.175000	152.500000																																

$	13-Dec-2018	21:11:13.272	Ascend	ERROR: Missed PH message 9

$	13-Dec-2018	21:11:13.378	Ascend	Sending Optode Do Sample

$	13-Dec-2018	21:11:13.382	Ascend	Sending Optode Wakeup

$	13-Dec-2018	21:11:13.984	Ascend	Sci Logger sample Optode

$	13-Dec-2018	21:11:14.001	Ascend	Sci Logger sample pH and NO3

$	13-Dec-2018	21:11:14.103	Ascend	Sending FLBB run command

$	13-Dec-2018	21:11:14.204	Ascend	Sci Logger sample FLBB

$	13-Dec-2018	21:11:14.309	Ascend	Sending radiometer pollSample

$	13-Dec-2018	21:11:14.411	Ascend	Sci Logger sample Radiometer

$	13-Dec-2018	21:11:14.625	Ascend	CTD post: 1.76	22.196	35.22

$	13-Dec-2018	21:11:13.022	Ascend	Vel PID Values																		0.050000	0.070000	0.071531	-0.458864	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:13.022	Ascend	SBE41 Message						    1.76, 22.1956, 35.2189  	1.760000	3.013535	-0.047250	0.070000	0.300000	0.049816	1.000000																							

$	13-Dec-2018	21:11:13.956	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009731	-0.081263	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:13.956	Ascend	SBE41 Message						    1.77, 22.1964, 35.2186  	1.770000	2.921341	-0.026188	-0.010000	0.030000	0.046827	1.000000																							

$	13-Dec-2018	21:11:15.305	Ascend	Radiometer Message																																	SATFI40287,-0.0051,0.0029,-0.0087,-0.2183 			

$	13-Dec-2018	21:11:15.520	Ascend	Radiometer post: SATFI40287,-0.0051,0.0029,-0.0087,-0.2183 

$	13-Dec-2018	21:11:15.057	Ascend	Vel PID Values																		0.050000	0.010000	0.009934	0.019665	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:15.057	Ascend	SBE41 Message						    1.76, 22.1965, 35.2188  	1.760000	2.710093	0.015655	0.010000	0.000000	0.044259	1.000000																							

$	13-Dec-2018	21:11:15.076	Ascend	Optode Message																												4330,1532,265.329,22.489,29.133,29.063,36.114,7.051,530.6,463.1,110.7  								

$	13-Dec-2018	21:11:16.082	Ascend	Optode post: 4330,1532,265.329,22.489,29.133,29.063,36.114,7.051,530.6,463.1,110.7  

$	13-Dec-2018	21:11:16.389	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.760000	145.208158	51.175000	152.500000																																

$	13-Dec-2018	21:11:16.500	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.2357871

$	13-Dec-2018	21:11:15.078	Ascend	Optode Message																												#  								

$	13-Dec-2018	21:11:16.715	Ascend	FLBB Message																											/99/99,99:99:99,695,2309,700,4130,532  									

$	13-Dec-2018	21:11:16.827	Ascend	FLBB post: /99/99,99:99:99,695,2309,700,4130,532  

$	13-Dec-2018	21:11:15.967	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	0.000066	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:15.967	Ascend	SBE41 Message						    1.75, 22.1956, 35.2193  	1.750000	2.397131	0.069283	0.010000	0.010000	0.042512	1.000000																							

$	13-Dec-2018	21:11:17.474	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.750000	145.202622	51.175000	152.500000																																

$	13-Dec-2018	21:11:17.586	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0811482

$	13-Dec-2018	21:11:16.952	Ascend	Vel PID Values																		0.050000	0.020000	0.019967	0.009967	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:16.952	Ascend	SBE41 Message						    1.73, 22.1957, 35.2191  	1.730000	2.087064	0.116119	0.020000	0.015000	0.041714	1.000000																							

$	13-Dec-2018	21:11:18.033	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:18.033	Ascend	SBE41 Message						    1.71, 22.1960, 35.2191  	1.710000	1.880548	0.144097	0.020000	0.020000	0.041876	1.000000																							

$	13-Dec-2018	21:11:18.577	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.710000	145.206936	51.175000	152.500000																																

$	13-Dec-2018	21:11:18.690	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0978808

$	13-Dec-2018	21:11:18.995	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.710000	145.202227	51.175000	152.500000																																

$	13-Dec-2018	21:11:18.950	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	0.000000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:18.950	Ascend	SBE41 Message						    1.69, 22.1960, 35.2193  	1.690000	1.788840	0.155331	0.020000	0.020000	0.043038	1.000000																							

$	13-Dec-2018	21:11:20.038	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	0.000000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:20.038	Ascend	SBE41 Message						    1.67, 22.1968, 35.2185  	1.670000	1.758935	0.158303	0.020000	0.020000	0.045117	1.000000																							

$	13-Dec-2018	21:11:20.582	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.670000	145.196885	51.175000	152.500000																																

$	13-Dec-2018	21:11:20.695	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0003783

$	13-Dec-2018	21:11:21.000	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.670000	145.203941	51.175000	152.500000																																

$	13-Dec-2018	21:11:20.949	Ascend	Vel PID Values																		0.050000	0.020000	0.020000	-0.000000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:20.949	Ascend	SBE41 Message						    1.65, 22.1971, 35.2187  	1.650000	1.744241	0.157032	0.020000	0.020000	0.047781	1.000000																							

$	13-Dec-2018	21:11:22.046	Ascend	MSC: RX: ACK,TS,DAT 

$	13-Dec-2018	21:11:22.045	Ascend	Vel PID Values																		0.050000	0.010000	0.010033	-0.009967	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:22.045	Ascend	SBE41 Message						    1.64, 22.1964, 35.2195  	1.640000	1.728219	0.147582	0.010000	0.015000	0.050601	1.000000																							

$	13-Dec-2018	21:11:22.692	Ascend	PTH Message														788.482666	23.733333	52.521271	24.525525																			

$	13-Dec-2018	21:11:22.894	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.640000	145.217083	31.025000	163.000000																																

$	13-Dec-2018	21:11:23.006	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3058816

$	13-Dec-2018	21:11:23.004	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.010000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:23.004	Ascend	SBE41 Message						    1.64, 22.1973, 35.2187  	1.640000	1.709688	0.123721	0.000000	0.005000	0.053301	1.000000																							

$	13-Dec-2018	21:11:23.656	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.640000	145.208120	31.025000	163.000000																																

$	13-Dec-2018	21:11:24.014	Ascend	MSC: OUT: SL

$	13-Dec-2018	21:11:23.946	Ascend	Vel PID Values																		0.050000	-0.170000	-0.169434	-0.169468	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:23.946	Ascend	SBE41 Message						    1.81, 22.1969, 35.2185  	1.810000	1.690344	0.087396	-0.170000	-0.085000	0.055822	1.000000																							

$	13-Dec-2018	21:11:24.661	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.810000	145.222493	31.025000	163.000000																																

$	13-Dec-2018	21:11:25.015	Ascend	MSC: RX: 0xEE76,pH,02/01/2012 03:36:33,0,-1.00,-1.0000,-1.0000,281,163,0,22.86,54.25,11.744,4.620e-02,7.1234,0.000,-0.972439,0.000772,-0.965373,

$	13-Dec-2018	21:11:25.021	Ascend	MSC: Data: 0xEE76,pH,02/01/2012 03:36:33,0,-1.00,-1.0000,-1.0000,281,163,0,22.86,54.25,11.744,4.620e-02,7.1234,0.000,-0.972439,0.000772,-0.965373,

$	13-Dec-2018	21:11:25.222	Ascend	MSC post: 7.1234

$	13-Dec-2018	21:11:24.945	Ascend	Vel PID Values																		0.050000	-0.070000	-0.070332	0.099102	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:24.945	Ascend	SBE41 Message						    1.88, 22.1969, 35.2189  	1.880000	1.672569	0.051251	-0.070000	-0.120000	0.058141	1.000000																							

$	13-Dec-2018	21:11:25.869	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.880000	145.206928	31.025000	163.000000																																

$	13-Dec-2018	21:11:26.014	Ascend	MSC: Done Sampling.

$	13-Dec-2018	21:11:26.117	Ascend	MSC: OUT: SLP

$	13-Dec-2018	21:11:25.979	Ascend	Vel PID Values																		0.050000	0.020000	0.019700	0.090032	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:25.979	Ascend	SBE41 Message						    1.86, 22.1973, 35.2190  	1.860000	1.662546	0.026958	0.020000	-0.025000	0.060124	1.000000																							

$	13-Dec-2018	21:11:26.763	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.860000	145.198688	31.025000	163.000000																																

$	13-Dec-2018	21:11:27.015	Ascend	MSC: RX: ACK,SLP 

$	13-Dec-2018	21:11:26.942	Ascend	Vel PID Values																		0.050000	0.010000	0.010033	-0.009667	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:26.942	Ascend	SBE41 Message						    1.85, 22.1970, 35.2193  	1.850000	1.672645	0.014374	0.010000	0.015000	0.061447	1.000000																							

$	13-Dec-2018	21:11:27.660	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.850000	145.217448	31.025000	163.000000																																

$	13-Dec-2018	21:11:27.942	Ascend	Vel PID Values																		0.050000	0.010000	0.010000	-0.000033	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:27.942	Ascend	SBE41 Message						    1.84, 22.1975, 35.2188  	1.840000	1.712266	0.005778	0.010000	0.010000	0.061772	1.000000																							

$	13-Dec-2018	21:11:28.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.840000	145.202205	31.025000	163.000000																																

$	13-Dec-2018	21:11:28.940	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009967	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:28.940	Ascend	SBE41 Message						    1.84, 22.1977, 35.2190  	1.840000	1.771275	-0.003338	0.000000	0.005000	0.060964	1.000000																							

$	13-Dec-2018	21:11:29.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.840000	145.206898	31.025000	163.000000																																

$	13-Dec-2018	21:11:29.939	Ascend	Vel PID Values																		0.050000	0.010000	0.009967	0.009933	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:29.939	Ascend	SBE41 Message						    1.83, 22.1980, 35.2187  	1.830000	1.822464	-0.011654	0.010000	0.005000	0.059223	1.000000																							

$	13-Dec-2018	21:11:30.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.830000	145.194970	31.025000	163.000000																																

$	13-Dec-2018	21:11:30.939	Ascend	Vel PID Values																		0.050000	0.000000	0.000033	-0.009934	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:30.939	Ascend	SBE41 Message						    1.83, 22.1985, 35.2185  	1.830000	1.847226	-0.017016	0.000000	0.005000	0.056867	1.000000																							

$	13-Dec-2018	21:11:31.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.830000	145.212099	31.025000	163.000000																																

$	13-Dec-2018	21:11:31.937	Ascend	Vel PID Values																		0.050000	-0.010000	-0.009967	-0.010000	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:31.937	Ascend	SBE41 Message						    1.84, 22.1986, 35.2190  	1.840000	1.849767	-0.019728	-0.010000	-0.005000	0.054099	1.000000																							

$	13-Dec-2018	21:11:32.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.840000	145.213470	31.025000	163.000000																																

$	13-Dec-2018	21:11:32.936	Ascend	Vel PID Values																		0.050000	0.000000	-0.000033	0.009933	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:32.936	Ascend	SBE41 Message						    1.84, 22.1978, 35.2193  	1.840000	1.844042	-0.021220	0.000000	-0.005000	0.050973	1.000000																							

$	13-Dec-2018	21:11:33.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.840000	145.222910	31.025000	163.000000																																

$	13-Dec-2018	21:11:33.935	Ascend	Vel PID Values																		0.050000	0.460000	0.458469	0.458502	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:33.935	Ascend	SBE41 Message						    1.38, 22.1985, 35.2191  	1.380000	1.838456	-0.021764	0.460000	0.230000	0.047526	1.000000																							

$	13-Dec-2018	21:11:34.558	Ascend	RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	1.380000	145.224318	31.025000	163.000000																																

$	13-Dec-2018	21:11:35.016	Ascend	Sending SBE41 stopProfile

$	13-Dec-2018	21:11:34.934	Ascend	Vel PID Values																		0.050000	0.560000	0.559665	0.101195	NaN	NaN	NaN	0.000000	1.000000										

$	13-Dec-2018	21:11:34.934	Ascend	SBE41 Message						    0.82, 22.1986, 35.2192  	0.820000	1.833949	-0.019951	0.560000	0.510000	0.043948	1.000000																							

$	13-Dec-2018	21:11:35.165	Ascend	Unparsed SBE41 Message						profile stopped  																														

$	13-Dec-2018	21:11:35.696	Ascend	Sending SBE41 stopProfile

$	13-Dec-2018	21:11:35.700	Ascend	Powering up GPS

$	13-Dec-2018	21:11:35.816	Ascend	Powering up BT Module

$	13-Dec-2018	21:11:35.917	Ascend	Normal State Exit

$	13-Dec-2018	21:11:36.119	Ascend	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 26  Pres, BP, BatV, BatI: 	0.820000	145.212263	31.025000	163.000000																																

$	13-Dec-2018	21:11:36.234	Ascend	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2183723

$	13-Dec-2018	21:11:36.336	Init Profile	State Entry

$	13-Dec-2018	21:11:36.341	Init Profile	Initializing SBE 41 LPF

$	13-Dec-2018	21:11:36.550	Init Profile	Sending SBE41 stopProfile

$	13-Dec-2018	21:11:37.652	Init Profile	Resetting SBE41 with qsr

$	13-Dec-2018	21:11:37.657	Init Profile	Sending qsr command

$	13-Dec-2018	21:11:35.812	Init Profile	Unparsed SBE41 Message						S>stopprofile  																														

$	13-Dec-2018	21:11:40.160	Init Profile	Normal State Exit

$	13-Dec-2018	21:11:40.164	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.214826	31.025000	163.000000																																

$	13-Dec-2018	21:11:40.377	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.0406028

$	13-Dec-2018	21:11:40.383	Surface Ops Set Bellows	State Entry

$	13-Dec-2018	21:11:40.587	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	13-Dec-2018	21:11:36.682	Surface Ops Set Bellows	Unparsed SBE41 Message						?cmd S>stopprofile  																														

$	13-Dec-2018	21:11:37.860	Surface Ops Set Bellows	Unparsed SBE41 Message						?cmd S>qsr  																														

$	13-Dec-2018	21:11:37.861	Surface Ops Set Bellows	Unparsed SBE41 Message						powering down  																														

$	13-Dec-2018	21:11:40.088	Surface Ops Set Bellows	Unparsed SBE41 Message						S>SBE 41CP UW V 2.0  																														

$	13-Dec-2018	21:11:41.675	Surface Ops Set Bellows	Normal State Exit

$	13-Dec-2018	21:11:41.679	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.166978	31.025000	163.000000																																

$	13-Dec-2018	21:11:41.893	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5102212

$	13-Dec-2018	21:11:41.900	Dump CP Data	State Entry

$	13-Dec-2018	21:11:42.002	Dump CP Data	Starting valve close

$	13-Dec-2018	21:11:42.208	Dump CP Data	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:11:42.514	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.198762	31.025000	163.000000																																

$	13-Dec-2018	21:11:42.901	Dump CP Data	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:11:43.207	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.168595	31.025000	163.000000																																

$	13-Dec-2018	21:11:43.901	Dump CP Data	Didn't get CR/LF response, trying again

$	13-Dec-2018	21:11:42.208	Dump CP Data	CP Message						S>  																														

$	13-Dec-2018	21:11:44.216	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.203277	31.025000	163.000000																																

$	13-Dec-2018	21:11:44.901	Dump CP Data	Got CR/LF response

$	13-Dec-2018	21:11:45.107	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.213664	31.025000	163.000000																																

$	13-Dec-2018	21:11:45.902	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:45.906	Dump CP Data	Sending binaverage

$	13-Dec-2018	21:11:46.008	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:46.118	Dump CP Data	CP Message						S>binaverage  																														

$	13-Dec-2018	21:11:46.119	Dump CP Data	CP Message						samples = 497, maxPress = 25.82  																														

$	13-Dec-2018	21:11:46.223	Dump CP Data	CP Message						rd: 0  																														

$	13-Dec-2018	21:11:46.750	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.194136	31.025000	163.000000																																

$	13-Dec-2018	21:11:46.902	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:46.907	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:47.210	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.198837	31.025000	163.000000																																

$	13-Dec-2018	21:11:47.903	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:47.907	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:47.593	Dump CP Data	CP Message						rd: 128  																														

$	13-Dec-2018	21:11:48.418	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.212166	31.025000	163.000000																																

$	13-Dec-2018	21:11:48.903	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:48.907	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:49.005	Dump CP Data	CP Message						rd: 256  																														

$	13-Dec-2018	21:11:49.322	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.213731	31.025000	163.000000																																

$	13-Dec-2018	21:11:49.903	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:49.908	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:50.212	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.198472	31.025000	163.000000																																

$	13-Dec-2018	21:11:50.904	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:50.908	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:50.377	Dump CP Data	CP Message						rd: 384  																														

$	13-Dec-2018	21:11:51.320	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.194128	31.025000	163.000000																																

$	13-Dec-2018	21:11:51.904	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:52.006	Dump CP Data	Trying again for binaverage response

$	13-Dec-2018	21:11:51.596	Dump CP Data	CP Message						avg: 0  																														

$	13-Dec-2018	21:11:51.707	Dump CP Data	CP Message						  																														

$	13-Dec-2018	21:11:51.727	Dump CP Data	CP Message						done, nbins = 14  																														

$	13-Dec-2018	21:11:52.636	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.200185	31.025000	163.000000																																

$	13-Dec-2018	21:11:52.904	Dump CP Data	Sending binaverage wait command

$	13-Dec-2018	21:11:53.006	Dump CP Data	Got good binaverage response

$	13-Dec-2018	21:11:53.213	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.206109	31.025000	163.000000																																

$	13-Dec-2018	21:11:53.904	Dump CP Data	Sending da wait command

$	13-Dec-2018	21:11:53.909	Dump CP Data	Sending da command

$	13-Dec-2018	21:11:54.010	Dump CP Data	Trying again for da response

$	13-Dec-2018	21:11:54.111	Dump CP Data	CP Message						S>da  																														

$	13-Dec-2018	21:11:54.112	Dump CP Data	CP Message						    0.82, 22.1986, 35.2192, 1  																														

$	13-Dec-2018	21:11:54.216	Dump CP Data	CP Message						    2.04, 22.1956, 35.2188, 34  																														

$	13-Dec-2018	21:11:54.216	Dump CP Data	CP Message						    3.99, 22.1912, 35.2176, 44  																														

$	13-Dec-2018	21:11:54.217	Dump CP Data	CP Message						    6.05, 22.1848, 35.2164, 39  																														

$	13-Dec-2018	21:11:54.328	Dump CP Data	CP Message						    8.14, 22.1794, 35.2150, 43  																														

$	13-Dec-2018	21:11:54.328	Dump CP Data	CP Message						   10.07, 22.1744, 35.2136, 31  																														

$	13-Dec-2018	21:11:54.329	Dump CP Data	CP Message						   11.83, 22.1705, 35.2126, 38  																														

$	13-Dec-2018	21:11:54.438	Dump CP Data	CP Message						   13.99, 22.1646, 35.2114, 45  																														

$	13-Dec-2018	21:11:54.439	Dump CP Data	CP Message						   15.92, 22.1606, 35.2102, 33  																														

$	13-Dec-2018	21:11:54.440	Dump CP Data	CP Message						   17.88, 22.1555, 35.2091, 44  																														

$	13-Dec-2018	21:11:54.441	Dump CP Data	CP Message						   20.21, 22.1476, 35.2070, 45  																														

$	13-Dec-2018	21:11:54.553	Dump CP Data	CP Message						   21.97, 22.1395, 35.2068, 24  																														

$	13-Dec-2018	21:11:54.554	Dump CP Data	CP Message						   23.97, 22.1284, 35.2039, 57  																														

$	13-Dec-2018	21:11:54.555	Dump CP Data	CP Message						   25.54, 22.1203, 35.2019, 19  																														

$	13-Dec-2018	21:11:54.664	Dump CP Data	CP Message						upload complete  																														

$	13-Dec-2018	21:11:56.076	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.199738	31.025000	163.000000																																

$	13-Dec-2018	21:11:56.188	Dump CP Data	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.2835730

$	13-Dec-2018	21:11:56.291	Dump CP Data	Sending da wait command

$	13-Dec-2018	21:11:56.297	Dump CP Data	Good da response; Upload sucessful

$	13-Dec-2018	21:11:56.698	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.200148	31.025000	163.000000																																

$	13-Dec-2018	21:11:57.291	Dump CP Data	Sending dah wait command

$	13-Dec-2018	21:11:57.296	Dump CP Data	Sending dah command

$	13-Dec-2018	21:11:57.397	Dump CP Data	Trying again for dah response

$	13-Dec-2018	21:11:57.499	Dump CP Data	CP Message						S>dah  																														

$	13-Dec-2018	21:11:57.726	Dump CP Data	Appending CP Data: 000856B7899301  

$	13-Dec-2018	21:11:57.500	Dump CP Data	CP Message						000856B7899301  																														

$	13-Dec-2018	21:11:57.936	Dump CP Data	Appending CP Data: 001456B4899322  

$	13-Dec-2018	21:11:57.500	Dump CP Data	CP Message						001456B4899322  																														

$	13-Dec-2018	21:11:58.147	Dump CP Data	Appending CP Data: 002856AF89922C  

$	13-Dec-2018	21:11:57.501	Dump CP Data	CP Message						002856AF89922C  																														

$	13-Dec-2018	21:11:58.359	Dump CP Data	Appending CP Data: 003D56A9899027  

$	13-Dec-2018	21:11:57.501	Dump CP Data	CP Message						003D56A9899027  																														

$	13-Dec-2018	21:11:58.570	Dump CP Data	Appending CP Data: 005156A3898F2B  

$	13-Dec-2018	21:11:57.605	Dump CP Data	CP Message						005156A3898F2B  																														

$	13-Dec-2018	21:11:58.780	Dump CP Data	Appending CP Data: 0065569E898E1F  

$	13-Dec-2018	21:11:57.605	Dump CP Data	CP Message						0065569E898E1F  																														

$	13-Dec-2018	21:11:58.993	Dump CP Data	Appending CP Data: 0076569A898D26  

$	13-Dec-2018	21:11:57.606	Dump CP Data	CP Message						0076569A898D26  																														

$	13-Dec-2018	21:11:59.203	Dump CP Data	Appending CP Data: 008C5695898B2D  

$	13-Dec-2018	21:11:57.606	Dump CP Data	CP Message						008C5695898B2D  																														

$	13-Dec-2018	21:11:59.415	Dump CP Data	Appending CP Data: 009F5691898A21  

$	13-Dec-2018	21:11:57.607	Dump CP Data	CP Message						009F5691898A21  																														

$	13-Dec-2018	21:11:59.626	Dump CP Data	Appending CP Data: 00B3568B89892C  

$	13-Dec-2018	21:11:57.607	Dump CP Data	CP Message						00B3568B89892C  																														

$	13-Dec-2018	21:11:59.836	Dump CP Data	Appending CP Data: 00CA568489872D  

$	13-Dec-2018	21:11:57.722	Dump CP Data	CP Message						00CA568489872D  																														

$	13-Dec-2018	21:12:00.049	Dump CP Data	Appending CP Data: 00DC567C898718  

$	13-Dec-2018	21:11:57.723	Dump CP Data	CP Message						00DC567C898718  																														

$	13-Dec-2018	21:12:00.259	Dump CP Data	Appending CP Data: 00F05670898439  

$	13-Dec-2018	21:11:57.724	Dump CP Data	CP Message						00F05670898439  																														

$	13-Dec-2018	21:12:00.470	Dump CP Data	Appending CP Data: 00FF5668898213  

$	13-Dec-2018	21:11:57.724	Dump CP Data	CP Message						00FF5668898213  																														

$	13-Dec-2018	21:11:57.725	Dump CP Data	CP Message						upload complete  																														

$	13-Dec-2018	21:12:00.894	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.210981	31.025000	163.000000																																

$	13-Dec-2018	21:12:01.006	Dump CP Data	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.7144126

$	13-Dec-2018	21:12:01.013	Dump CP Data	Sending dah wait command

$	13-Dec-2018	21:12:01.212	Dump CP Data	Good dah response; Upload sucessful

$	13-Dec-2018	21:12:01.516	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.202458	31.025000	163.000000																																

$	13-Dec-2018	21:12:03.014	Dump CP Data	Calculated new PID Constant, h = 3000

$	13-Dec-2018	21:12:02.019	Dump CP Data	CP Message						S>  																														

$	13-Dec-2018	21:12:03.331	Dump CP Data	Normal State Exit

$	13-Dec-2018	21:12:03.335	Dump CP Data	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.820000	145.212047	31.025000	163.000000																																

$	13-Dec-2018	21:12:03.552	Dump CP Data	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5390375

$	13-Dec-2018	21:12:03.655	Surface Ops	State Entry

$	13-Dec-2018	21:12:03.762	Surface Ops	Powering up Iridium Modem
