$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	11-Dec-2018	00:36:56.778	SM Not Running	Reset Controller Status Register Value = 65792

$	11-Dec-2018	00:36:56.783	SM Not Running	File Name = \SD\data\2018-12-11T0-36-55.eng

$	11-Dec-2018	00:36:56.788	SM Not Running	Volume Total Size:     7939817472

$	11-Dec-2018	00:36:56.792	SM Not Running	Volume Free Space:     7883718656

$	11-Dec-2018	00:36:56.797	SM Not Running	PlatVel PID K = 80

$	11-Dec-2018	00:36:56.801	SM Not Running	PlatVel PID Ti = 50000

$	11-Dec-2018	00:36:56.805	SM Not Running	PlatVel PID Td = 10

$	11-Dec-2018	00:36:56.809	SM Not Running	PlatVel PID Tf = 10

$	11-Dec-2018	00:36:56.813	SM Not Running	PlatVel PID Tt = 100

$	11-Dec-2018	00:36:56.817	SM Not Running	PlatVel PID B = 1

$	11-Dec-2018	00:36:56.821	SM Not Running	PlatVel PID uLow = -50

$	11-Dec-2018	00:36:56.826	SM Not Running	PlatVel PID uHigh = 50

$	11-Dec-2018	00:36:56.830	SM Not Running	PlatVel PID h = 3

$	11-Dec-2018	00:36:56.833	SM Not Running	Engr Logger Initialized

$	11-Dec-2018	00:36:56.837	SM Not Running	Initializing Bluetooth Console

$	11-Dec-2018	00:36:57.842	SM Not Running	Initializing GPS and synching time

$	11-Dec-2018	00:37:00.001	SM Not Running	Creating Mission

$	11-Dec-2018	00:37:00.104	SM Not Running	Maximum number of profiles = 10

$	11-Dec-2018	00:37:00.208	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 12/11/2018 00:37:00

$	11-Dec-2018	00:37:00.310	SM Not Running	Recovery mode = True

$	11-Dec-2018	00:37:00.315	SM Not Running	Park Sample Period = 00:01:00

$	11-Dec-2018	00:37:00.515	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	11-Dec-2018	00:37:00.619	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:00.724	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:00.828	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:00.932	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.036	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.140	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.244	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.348	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.452	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.556	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.660	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.764	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.868	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:01.972	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.077	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.181	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.285	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.388	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.493	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.597	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.701	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.805	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:02.910	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:03.014	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:03.118	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:03.222	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:03.326	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.050, 00:00:00, 7

$	11-Dec-2018	00:37:03.332	SM Not Running	Initializing Buoyancy Engine

$	11-Dec-2018	00:37:03.533	SM Not Running	Starting valve close

$	11-Dec-2018	00:37:03.539	Init Mission	State Entry

$	11-Dec-2018	00:37:03.739	Init Mission	Initializing FLBB

$	11-Dec-2018	00:37:08.246	Init Mission	Sending FLBB stop command

$	11-Dec-2018	00:37:09.850	Init Mission	Sending FLBB pkt command: $pkt 1  

$	11-Dec-2018	00:37:10.954	Init Mission	Sending FLBB ave command: $ave 10  

$	11-Dec-2018	00:37:13.058	Init Mission	Initializing Iridium Modem

$	11-Dec-2018	00:37:22.571	Init Mission	Initializing SBE41

$	11-Dec-2018	00:37:28.183	Init Mission	Sending SBE41 stopProfile

$	11-Dec-2018	00:37:29.188	Init Mission	pcutoff=1 

$	11-Dec-2018	00:37:30.192	Init Mission	Sending outputPTSyes

$	11-Dec-2018	00:37:31.198	Init Mission	Sending tsWait

$	11-Dec-2018	00:37:32.202	Init Mission	Sending 11 bin setup commands

$	11-Dec-2018	00:37:38.811	Init Mission	Initializing Optode

$	11-Dec-2018	00:37:39.413	Init Mission	Sending Optode Wakeup

$	11-Dec-2018	00:37:44.420	Init Mission	Initializing Pressure, Temperature, Humidity sensor

$	11-Dec-2018	00:37:44.928	Init Mission	Set can pressure resolution to low

$	11-Dec-2018	00:37:45.030	Init Mission	Set can pressure active

$	11-Dec-2018	00:37:45.034	Init Mission	PTH Message														774.810059	22.816667	53.551239	23.892744																			

$	11-Dec-2018	00:37:45.236	Init Mission	Initializing MSC

$	11-Dec-2018	00:37:45.936	Init Mission	MSC: OUT: INIT

$	11-Dec-2018	00:37:46.039	Init Mission	Initializing Radiometer 1

$	11-Dec-2018	00:37:46.551	Init Mission	Powering down OCR504

$	11-Dec-2018	00:37:51.556	Init Mission	Powering up OCR504

$	11-Dec-2018	00:37:56.560	Init Mission	FLBB Message																											/99/99,99:99:99,695,2297,700,4130,541  									

$	11-Dec-2018	00:37:16.574	Init Mission	A3LA Message																																			AT&D0   	

$	11-Dec-2018	00:37:16.576	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:17.574	Init Mission	A3LA Message																																			AT&K0   	

$	11-Dec-2018	00:37:17.576	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:18.577	Init Mission	A3LA Message																																			AT+SBDD2   	

$	11-Dec-2018	00:37:18.579	Init Mission	A3LA Message																																			0  	

$	11-Dec-2018	00:37:18.580	Init Mission	A3LA Message																																			  	

$	11-Dec-2018	00:37:18.582	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:19.582	Init Mission	A3LA Message																																			AT+GSN    	

$	11-Dec-2018	00:37:19.591	Init Mission	A3LA Message																																			300125060561320  	

$	11-Dec-2018	00:37:19.592	Init Mission	A3LA Message																																			  	

$	11-Dec-2018	00:37:19.594	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:20.760	Init Mission	A3LA Message																																			AT+SBDC   	

$	11-Dec-2018	00:37:20.762	Init Mission	A3LA Message																																			0  	

$	11-Dec-2018	00:37:20.763	Init Mission	A3LA Message																																			  	

$	11-Dec-2018	00:37:58.402	Init Mission	PTH Message														774.810059	22.866667	53.581757	23.882019																			

$	11-Dec-2018	00:37:58.605	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	28.775000	108.000000																																

$	11-Dec-2018	00:37:58.618	Init Mission	Starting valve close

$	11-Dec-2018	00:38:00.720	Init Mission	Closed valve isValveOpen = false

$	11-Dec-2018	00:38:00.818	Init Mission	Starting valve open

$	11-Dec-2018	00:38:02.919	Init Mission	Opened valve isValveOpen = true

$	11-Dec-2018	00:38:03.019	Init Mission	Starting valve close

$	11-Dec-2018	00:38:05.121	Init Mission	Closed valve isValveOpen = false

$	11-Dec-2018	00:37:20.765	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:21.739	Init Mission	A3LA Message																																			ATEn=0   	

$	11-Dec-2018	00:37:21.742	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:22.678	Init Mission	A3LA Message																																			  	

$	11-Dec-2018	00:37:22.679	Init Mission	A3LA Message																																			8988169234000597401  	

$	11-Dec-2018	00:37:22.679	Init Mission	A3LA Message																																			  	

$	11-Dec-2018	00:37:22.679	Init Mission	A3LA Message																																			OK  	

$	11-Dec-2018	00:37:28.298	Init Mission	Unparsed SBE41 Message						S>stopprofile  																														

$	11-Dec-2018	00:37:29.301	Init Mission	Unparsed SBE41 Message						?cmd S>pcutoff=1  																														

$	11-Dec-2018	00:37:30.308	Init Mission	Unparsed SBE41 Message						S>outputpts=y  																														

$	11-Dec-2018	00:37:31.310	Init Mission	Unparsed SBE41 Message						S>tswait=2  																														

$	11-Dec-2018	00:37:32.341	Init Mission	Unparsed SBE41 Message						S>autobinavg=n  																														

$	11-Dec-2018	00:37:32.856	Init Mission	Unparsed SBE41 Message						S>top_bin_interval=2  																														

$	11-Dec-2018	00:37:33.345	Init Mission	Unparsed SBE41 Message						S>top_bin_size=2  																														

$	11-Dec-2018	00:37:33.845	Init Mission	Unparsed SBE41 Message						S>top_bin_max=10  																														

$	11-Dec-2018	00:38:07.217	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	28.775000	108.000000																																

$	11-Dec-2018	00:38:07.326	Init Mission	Starting valve open

$	11-Dec-2018	00:38:07.632	Init Mission	Bellows inside limits

$	11-Dec-2018	00:37:34.363	Init Mission	Unparsed SBE41 Message						S>middle_bin_interval=2  																														

$	11-Dec-2018	00:37:34.854	Init Mission	Unparsed SBE41 Message						S>middle_bin_size=2  																														

$	11-Dec-2018	00:37:35.355	Init Mission	Unparsed SBE41 Message						S>middle_bin_max=20  																														

$	11-Dec-2018	00:37:35.864	Init Mission	Unparsed SBE41 Message						S>bottom_bin_interval=2  																														

$	11-Dec-2018	00:37:36.354	Init Mission	Unparsed SBE41 Message						S>bottom_bin_size=2  																														

$	11-Dec-2018	00:37:36.868	Init Mission	Unparsed SBE41 Message						S>includetransitionbin=n  																														

$	11-Dec-2018	00:37:37.346	Init Mission	Unparsed SBE41 Message						S>includenbin=y  																														

$	11-Dec-2018	00:37:40.443	Init Mission	Optode Message																												!#  								

$	11-Dec-2018	00:37:41.454	Init Mission	Optode Message																												#  								

$	11-Dec-2018	00:37:42.465	Init Mission	Optode Message																												#  								

$	11-Dec-2018	00:38:08.796	Init Mission	MSC: RX: 

$	11-Dec-2018	00:38:08.995	Init Mission	MSC: RX: 

$	11-Dec-2018	00:38:09.097	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	11-Dec-2018	00:38:09.103	Init Mission	MSC: RX:   MBARI Serial Number : 0777 

$	11-Dec-2018	00:38:09.304	Init Mission	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	11-Dec-2018	00:38:09.407	Init Mission	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	11-Dec-2018	00:38:09.614	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	124.087855	28.775000	108.000000																																

$	11-Dec-2018	00:38:10.930	Init Mission	Increasing bellows position		124.861136																																		

$	11-Dec-2018	00:38:13.143	Init Mission	Increasing bellows position		125.170402																																		

$	11-Dec-2018	00:38:15.353	Init Mission	Increasing bellows position		125.536352																																		

$	11-Dec-2018	00:38:17.564	Init Mission	Increasing bellows position		125.820532																																		

$	11-Dec-2018	00:38:19.774	Init Mission	Increasing bellows position		125.997834																																		

$	11-Dec-2018	00:38:21.985	Init Mission	Increasing bellows position		126.015536																																		

$	11-Dec-2018	00:38:24.196	Init Mission	Increasing bellows position		126.057208																																		

$	11-Dec-2018	00:38:26.407	Init Mission	Increasing bellows position		126.050808																																		

$	11-Dec-2018	00:38:28.618	Init Mission	Increasing bellows position		126.072608																																		

$	11-Dec-2018	00:38:30.828	Init Mission	Increasing bellows position		126.092538																																		

$	11-Dec-2018	00:38:33.342	Init Mission	Decreasing bellows position		126.098320																																		

$	11-Dec-2018	00:38:35.552	Init Mission	Decreasing bellows position		126.104504																																		

$	11-Dec-2018	00:38:37.762	Init Mission	Decreasing bellows position		126.116976																																		

$	11-Dec-2018	00:38:39.973	Init Mission	Decreasing bellows position		126.116827																																		

$	11-Dec-2018	00:38:42.183	Init Mission	Decreasing bellows position		126.132913																																		

$	11-Dec-2018	00:38:44.395	Init Mission	Decreasing bellows position		126.139447																																		

$	11-Dec-2018	00:38:46.605	Init Mission	Decreasing bellows position		126.141205																																		

$	11-Dec-2018	00:38:48.816	Init Mission	Decreasing bellows position		126.146264																																		

$	11-Dec-2018	00:38:51.027	Init Mission	Decreasing bellows position		126.144886																																		

$	11-Dec-2018	00:38:53.244	Init Mission	Decreasing bellows position		126.160704																																		

$	11-Dec-2018	00:38:55.253	Init Mission	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	11-Dec-2018	00:38:55.354	Init Mission	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	11-Dec-2018	00:38:55.560	Init Mission	Radiometer Message																																	Firmware version: 5.1.0 - SatNet Type B 			

$	11-Dec-2018	00:38:55.573	Init Mission	Radiometer Message																																	Instrument: SATFI4 			

$	11-Dec-2018	00:38:55.681	Init Mission	Radiometer Message																																	S/N: 0287 			

$	11-Dec-2018	00:38:55.789	Init Mission	Radiometer Message																																	Reset Source: Power 			

$	11-Dec-2018	00:38:55.897	Init Mission	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	11-Dec-2018	00:38:56.105	Init Mission	Radiometer Message																																	Initializing system. Please wait... 			

$	11-Dec-2018	00:38:56.116	Init Mission	MSC: RX:   CF Card: Size=256614400 Avail=99.17% 

$	11-Dec-2018	00:38:56.316	Init Mission	MSC: RX:   CF2 Power Up  (GMT): Sun Jan 29 07:02:47 2012 

$	11-Dec-2018	00:38:56.321	Init Mission	MSC: RX:   CF2 RTC Time  (GMT): Sun Jan 29 07:02:51 2012 

$	11-Dec-2018	00:38:56.522	Init Mission	MSC: RX:   Adjusted Local Time: Sat Jan 28 23:02:51 2012 

$	11-Dec-2018	00:38:56.529	Init Mission	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	11-Dec-2018	00:38:56.729	Init Mission	MSC: RX:   RTC delta (CF2 - DS3234) : -1.00 secs. 

$	11-Dec-2018	00:38:56.734	Init Mission	MSC: RX:   System Batt Voltage = 11.764 

$	11-Dec-2018	00:38:56.934	Init Mission	MSC: RX:   System Load Current = 2.64e-02 

$	11-Dec-2018	00:38:57.238	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	126.149885	28.775000	108.000000																																

$	11-Dec-2018	00:38:57.352	Init Mission	MSC: RX:   Housing Temperature = +22.69C = +72.84F 

$	11-Dec-2018	00:38:57.357	Init Mission	MSC: RX:   Housing    Humidity =  54.2%  =  12.9C (DP) 

$	11-Dec-2018	00:38:57.557	Init Mission	MSC: RX:   Power Cycle   Count = 122 

$	11-Dec-2018	00:38:57.660	Init Mission	MSC: RX:   System Reset  Count = 126 

$	11-Dec-2018	00:38:57.762	Init Mission	MSC: RX:   System Error  Count = 56 

$	11-Dec-2018	00:38:57.866	Init Mission	MSC: RX:   Last System   Error = -107 

$	11-Dec-2018	00:38:57.968	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:29:34 2012 

$	11-Dec-2018	00:38:57.974	Init Mission	MSC: RX:   ISUS Error    Count = 1 

$	11-Dec-2018	00:38:58.076	Init Mission	MSC: RX:   Last ISUS     Error = -202 

$	11-Dec-2018	00:38:58.275	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	11-Dec-2018	00:38:58.281	Init Mission	MSC: RX:   DURA Error    Count = 0 

$	11-Dec-2018	00:38:58.482	Init Mission	MSC: RX:   Last DURA     Error = 0 

$	11-Dec-2018	00:38:58.584	Init Mission	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	11-Dec-2018	00:38:58.590	Init Mission	MSC: RX:   Fiberlite  Odometer = 100:10:09 = 360609 secs 

$	11-Dec-2018	00:38:58.693	Init Mission	MSC: RX:   Fiberlite    Cycles = 210 

$	11-Dec-2018	00:38:58.795	Init Mission	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	11-Dec-2018	00:38:59.101	Init Mission	PTH Message														775.012207	23.066667	53.368134	24.021445																			

$	11-Dec-2018	00:38:59.303	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	126.150481	28.700000	173.500000																																

$	11-Dec-2018	00:38:59.315	Init Mission	Sending SBE41 ds command

$	11-Dec-2018	00:38:59.417	Init Mission	Sending ds command

$	11-Dec-2018	00:38:59.622	Init Mission	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	11-Dec-2018	00:38:59.729	Init Mission	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	11-Dec-2018	00:38:59.833	Init Mission	MSC: RX:   There are 62 records in the error file! 

$	11-Dec-2018	00:38:59.937	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	11-Dec-2018	00:39:00.040	Init Mission	MSC: RX:   Auto Shutdown in 10 hours at: Sun Jan 29 17:02:52 2012 

$	11-Dec-2018	00:39:00.144	Init Mission	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	11-Dec-2018	00:39:00.152	Init Mission	Radiometer Message																																	Autonomous operation enabled. 			

$	11-Dec-2018	00:37:57.107	Init Mission	SBE41 Message						   -0.17  	-0.170000	-0.000001	-0.000000	0.056667	0.028333	0.000000	3.000000																							

$	11-Dec-2018	00:39:00.692	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.171567	28.700000	173.500000																																

$	11-Dec-2018	00:39:00.706	Init Mission	Sending SBE41 ds command

$	11-Dec-2018	00:39:01.109	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.170725	28.700000	173.500000																																

$	11-Dec-2018	00:39:01.706	Init Mission	Sending SBE41 ds command

$	11-Dec-2018	00:38:59.620	Init Mission	Unparsed SBE41 Message						S>ds  																														

$	11-Dec-2018	00:38:59.727	Init Mission	Unparsed SBE41 Message						firmware compilation date: 18 December 2007 09:20  																														

$	11-Dec-2018	00:38:59.728	Init Mission	Unparsed SBE41 Message						stop profile when pressure is less than = 1.0 decibars  																														

$	11-Dec-2018	00:38:59.832	Init Mission	Unparsed SBE41 Message						automatic bin averaging at end of profile disabled  																														

$	11-Dec-2018	00:38:59.936	Init Mission	Unparsed SBE41 Message						number of samples = 315  																														

$	11-Dec-2018	00:39:02.504	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.154825	28.700000	173.500000																																

$	11-Dec-2018	00:39:02.706	Init Mission	Sending SBE41 ds command

$	11-Dec-2018	00:38:59.942	Init Mission	Unparsed SBE41 Message						number of bins = 6  																														

$	11-Dec-2018	00:39:00.143	Init Mission	Unparsed SBE41 Message						top bin interval = 2  																														

$	11-Dec-2018	00:39:00.151	Init Mission	Unparsed SBE41 Message						top bin size = 2  																														

$	11-Dec-2018	00:39:00.249	Init Mission	Unparsed SBE41 Message						top bin max = 10  																														

$	11-Dec-2018	00:39:00.250	Init Mission	Unparsed SBE41 Message						middle bin interval = 2  																														

$	11-Dec-2018	00:39:00.251	Init Mission	Unparsed SBE41 Message						middle bin size = 2  																														

$	11-Dec-2018	00:39:00.251	Init Mission	Unparsed SBE41 Message						middle bin max = 20  																														

$	11-Dec-2018	00:39:00.252	Init Mission	Unparsed SBE41 Message						bottom bin interval = 2  																														

$	11-Dec-2018	00:39:00.253	Init Mission	Unparsed SBE41 Message						bottom bin size = 2  																														

$	11-Dec-2018	00:39:00.254	Init Mission	Unparsed SBE41 Message						do not include two transition bins  																														

$	11-Dec-2018	00:39:00.254	Init Mission	Unparsed SBE41 Message						include samples per bin  																														

$	11-Dec-2018	00:39:00.255	Init Mission	Unparsed SBE41 Message						pumped take sample wait time = 2 sec  																														

$	11-Dec-2018	00:39:00.256	Init Mission	Unparsed SBE41 Message						real-time output is PTS  																														

$	11-Dec-2018	00:39:04.440	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.173869	28.700000	173.500000																																

$	11-Dec-2018	00:39:04.555	Init Mission	Sending SBE41 ds command

$	11-Dec-2018	00:39:04.761	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.171097	28.700000	173.500000																																

$	11-Dec-2018	00:39:05.458	Init Mission	Sending SBE41 dc command

$	11-Dec-2018	00:39:05.463	Init Mission	Sending dc command

$	11-Dec-2018	00:39:05.768	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.166232	28.700000	173.500000																																

$	11-Dec-2018	00:39:06.457	Init Mission	Sending SBE41 dc command

$	11-Dec-2018	00:39:05.667	Init Mission	Unparsed SBE41 Message						S>dc  																														

$	11-Dec-2018	00:39:05.668	Init Mission	Unparsed SBE41 Message						temperature:  15-mar-14  																														

$	11-Dec-2018	00:39:05.695	Init Mission	Unparsed SBE41 Message						    TA0 =  3.536242e-05  																														

$	11-Dec-2018	00:39:05.731	Init Mission	Unparsed SBE41 Message						    TA1 =  2.674251e-04  																														

$	11-Dec-2018	00:39:05.767	Init Mission	Unparsed SBE41 Message						    TA2 = -1.901062e-06  																														

$	11-Dec-2018	00:39:05.878	Init Mission	Unparsed SBE41 Message						    TA3 =  1.365250e-07  																														

$	11-Dec-2018	00:39:05.879	Init Mission	Unparsed SBE41 Message						conductivity:  15-mar-14  																														

$	11-Dec-2018	00:39:05.880	Init Mission	Unparsed SBE41 Message						    G = -9.858232e-01  																														

$	11-Dec-2018	00:39:05.906	Init Mission	Unparsed SBE41 Message						    H =  1.476071e-01  																														

$	11-Dec-2018	00:39:05.940	Init Mission	Unparsed SBE41 Message						    I = -3.292498e-04  																														

$	11-Dec-2018	00:39:05.973	Init Mission	Unparsed SBE41 Message						    J =  4.505543e-05  																														

$	11-Dec-2018	00:39:06.011	Init Mission	Unparsed SBE41 Message						    CPCOR = -9.570001e-08  																														

$	11-Dec-2018	00:39:06.050	Init Mission	Unparsed SBE41 Message						    CTCOR =  3.250000e-06  																														

$	11-Dec-2018	00:39:06.088	Init Mission	Unparsed SBE41 Message						    WBOTC = -3.218098e-07  																														

$	11-Dec-2018	00:39:06.171	Init Mission	Unparsed SBE41 Message						pressure S/N = 4004719, range = 2900 psia:  10-mar-14  																														

$	11-Dec-2018	00:39:08.434	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.173869	28.700000	173.500000																																

$	11-Dec-2018	00:39:08.447	Init Mission	Sending SBE41 dc command

$	11-Dec-2018	00:39:06.207	Init Mission	Unparsed SBE41 Message						    PA0 =  1.629284e-01  																														

$	11-Dec-2018	00:39:06.243	Init Mission	Unparsed SBE41 Message						    PA1 =  1.404717e-01  																														

$	11-Dec-2018	00:39:06.280	Init Mission	Unparsed SBE41 Message						    PA2 = -3.503310e-08  																														

$	11-Dec-2018	00:39:06.319	Init Mission	Unparsed SBE41 Message						    PTCA0 =  2.758681e+01  																														

$	11-Dec-2018	00:39:06.357	Init Mission	Unparsed SBE41 Message						    PTCA1 =  2.201518e-02  																														

$	11-Dec-2018	00:39:06.395	Init Mission	Unparsed SBE41 Message						    PTCA2 =  1.374282e-03  																														

$	11-Dec-2018	00:39:06.435	Init Mission	Unparsed SBE41 Message						    PTCB0 =  2.510888e+01  																														

$	11-Dec-2018	00:39:06.560	Init Mission	Unparsed SBE41 Message						    PTCB1 =  1.175000e-03  																														

$	11-Dec-2018	00:39:06.561	Init Mission	Unparsed SBE41 Message						    PTCB2 =  0.000000e+00  																														

$	11-Dec-2018	00:39:06.561	Init Mission	Unparsed SBE41 Message						    PTHA0 = -7.442904e+01  																														

$	11-Dec-2018	00:39:06.680	Init Mission	Unparsed SBE41 Message						    PTHA1 =  4.994783e-02  																														

$	11-Dec-2018	00:39:06.681	Init Mission	Unparsed SBE41 Message						    PTHA2 = -3.966033e-07  																														

$	11-Dec-2018	00:39:06.682	Init Mission	Unparsed SBE41 Message						    POFFSET =  0.000000e+00  																														

$	11-Dec-2018	00:39:10.379	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.182482	28.700000	173.500000																																

$	11-Dec-2018	00:39:10.489	Init Mission	Sending SBE41 dc command

$	11-Dec-2018	00:39:10.787	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.154236	28.700000	173.500000																																

$	11-Dec-2018	00:39:11.593	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.170000	126.187056	28.700000	173.500000																																

$	11-Dec-2018	00:39:12.391	Init Mission	Sending Optode GetAll

$	11-Dec-2018	00:39:12.395	Init Mission	Sending Optode Wakeup

$	11-Dec-2018	00:39:12.364	Init Mission	SBE41 Message						   -0.12  	-0.120000	-0.000361	-0.000004	-0.016667	0.020000	0.000000	3.000000																							

$	11-Dec-2018	00:39:13.164	Init Mission	Optode Message																												%!Product Name,4330,1532,Optode Sensor  								

$	11-Dec-2018	00:39:13.197	Init Mission	Optode Message																												Product Number,4330,1532,4330  								

$	11-Dec-2018	00:39:13.228	Init Mission	Optode Message																												Serial Number,4330,1532,1532  								

$	11-Dec-2018	00:39:13.254	Init Mission	Optode Message																												SW ID,4330,1532,1940006  								

$	11-Dec-2018	00:39:13.283	Init Mission	Optode Message																												SW Version,4330,1532,4,8,1  								

$	11-Dec-2018	00:39:13.324	Init Mission	Optode Message																												Node Description,4330,1532,optode 1532  								

$	11-Dec-2018	00:39:13.343	Init Mission	Optode Message																												Owner,4330,1532,  								

$	11-Dec-2018	00:39:13.374	Init Mission	Optode Message																												Salinity[PSU],4330,1532,0.00  								

$	11-Dec-2018	00:39:13.450	Init Mission	Optode Message																												PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00  								

$	11-Dec-2018	00:39:13.476	Init Mission	Optode Message																												FoilID,4330,1532,1206E  								

$	11-Dec-2018	00:39:13.695	Init Mission	Optode Message																												FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04  								

$	11-Dec-2018	00:39:13.910	Init Mission	Optode Message																												FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	11-Dec-2018	00:39:13.992	Init Mission	Optode Message																												FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0  								

$	11-Dec-2018	00:39:17.792	Init Mission	Normal State Exit

$	11-Dec-2018	00:39:17.797	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.168944	28.700000	173.500000																																

$	11-Dec-2018	00:39:17.914	Init Profile	State Entry

$	11-Dec-2018	00:39:18.017	Init Profile	Initializing SBE 41 LPF

$	11-Dec-2018	00:39:18.226	Init Profile	Sending SBE41 stopProfile

$	11-Dec-2018	00:39:19.231	Init Profile	Resetting SBE41 with qsr

$	11-Dec-2018	00:39:19.239	Init Profile	Sending qsr command

$	11-Dec-2018	00:39:14.076	Init Profile	Optode Message																												FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0  								

$	11-Dec-2018	00:39:14.194	Init Profile	Optode Message																												SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	11-Dec-2018	00:39:14.243	Init Profile	Optode Message																												ConcCoef,4330,1532,-1.549127E+00,1.068129E+00  								

$	11-Dec-2018	00:39:14.280	Init Profile	Optode Message																												NomAirPress[hPa],4330,1532,1013.25  								

$	11-Dec-2018	00:39:14.310	Init Profile	Optode Message																												NomAirMix,4330,1532,0.20946  								

$	11-Dec-2018	00:39:14.351	Init Profile	Optode Message																												CalDataSat[Deg],4330,1532,31.61,10.06  								

$	11-Dec-2018	00:39:14.392	Init Profile	Optode Message																												CalDataAPress[hPa],4330,1532,1002.000  								

$	11-Dec-2018	00:39:14.435	Init Profile	Optode Message																												CalDataZero[Deg],4330,1532,61.907,21.413  								

$	11-Dec-2018	00:39:14.474	Init Profile	Optode Message																												Mode,4330,1532,Smart Sensor Terminal  								

$	11-Dec-2018	00:39:14.504	Init Profile	Optode Message																												Enable Sleep,4330,1532,Yes  								

$	11-Dec-2018	00:39:14.539	Init Profile	Optode Message																												Enable Polled Mode,4330,1532,Yes  								

$	11-Dec-2018	00:39:14.566	Init Profile	Optode Message																												Enable Text,4330,1532,No  								

$	11-Dec-2018	00:39:14.604	Init Profile	Optode Message																												Enable Decimalformat,4330,1532,Yes  								

$	11-Dec-2018	00:39:14.652	Init Profile	Optode Message																												Analog TempLimit[Deg.C],4330,1532,-5.00,35.00  								

$	11-Dec-2018	00:39:14.701	Init Profile	Optode Message																												Analog ConcLimit[Deg.C],4330,1532,0.00,800.00  								

$	11-Dec-2018	00:39:14.749	Init Profile	Optode Message																												Analog SatLimit[Deg.C],4330,1532,0.00,200.00  								

$	11-Dec-2018	00:39:23.353	Init Profile	Normal State Exit

$	11-Dec-2018	00:39:23.357	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.179598	28.700000	173.500000																																

$	11-Dec-2018	00:39:23.473	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.5583958

$	11-Dec-2018	00:39:23.576	Surface Ops Set Bellows	State Entry

$	11-Dec-2018	00:39:23.780	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	11-Dec-2018	00:39:14.798	Surface Ops Set Bellows	Optode Message																												Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00  								

$	11-Dec-2018	00:39:14.842	Surface Ops Set Bellows	Optode Message																												Analog Output,4330,1532,O2Concentration  								

$	11-Dec-2018	00:39:14.896	Surface Ops Set Bellows	Optode Message																												Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	11-Dec-2018	00:39:14.945	Surface Ops Set Bellows	Optode Message																												Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	11-Dec-2018	00:39:14.981	Surface Ops Set Bellows	Optode Message																												Enable AirSaturation,4330,1532,No  								

$	11-Dec-2018	00:39:15.013	Surface Ops Set Bellows	Optode Message																												Enable Rawdata,4330,1532,Yes  								

$	11-Dec-2018	00:39:15.048	Surface Ops Set Bellows	Optode Message																												Enable Temperature,4330,1532,Yes  								

$	11-Dec-2018	00:39:15.085	Surface Ops Set Bellows	Optode Message																												Enable HumidityComp,4330,1532,Yes  								

$	11-Dec-2018	00:39:15.118	Surface Ops Set Bellows	Optode Message																												Enable SVUformula,4330,1532,No  								

$	11-Dec-2018	00:39:15.148	Surface Ops Set Bellows	Optode Message																												Interval[s],4330,1532,30.000  								

$	11-Dec-2018	00:39:15.171	Surface Ops Set Bellows	Optode Message																												Location,4330,1532,  								

$	11-Dec-2018	00:39:15.221	Surface Ops Set Bellows	Optode Message																												Geographic Position,4330,1532,60.323605,5.37225  								

$	11-Dec-2018	00:39:15.252	Surface Ops Set Bellows	Optode Message																												Vertical Position,4330,1532,  								

$	11-Dec-2018	00:39:15.275	Surface Ops Set Bellows	Optode Message																												Reference,4330,1532,  								

$	11-Dec-2018	00:39:15.279	Surface Ops Set Bellows	Optode Message																												#  								

$	11-Dec-2018	00:39:26.082	Surface Ops Set Bellows	Normal State Exit

$	11-Dec-2018	00:39:26.183	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.194999	28.700000	173.500000																																

$	11-Dec-2018	00:39:26.300	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.6239964

$	11-Dec-2018	00:39:26.402	Pre-Mission Delay	State Entry

$	11-Dec-2018	00:39:15.364	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	-0.120000	0.000000	-0.003333	-0.001667	0.000000	3.000000																							

$	11-Dec-2018	00:39:26.838	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	126.204699	28.700000	173.500000																																

$	11-Dec-2018	00:39:18.371	Pre-Mission Delay	SBE41 Message						   -0.04  	-0.040000	-0.119978	0.000000	-0.023333	-0.013333	-0.000000	3.000000																							

$	11-Dec-2018	00:39:21.554	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	11-Dec-2018	00:39:22.007	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	11-Dec-2018	00:39:27.967	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.040000	126.211397	28.700000	173.500000																																

$	11-Dec-2018	00:39:28.607	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.040000	126.204252	28.700000	173.500000																																

$	11-Dec-2018	00:39:24.415	Pre-Mission Delay	SBE41 Message						   -0.06  	-0.060000	-0.119590	0.000004	0.006667	-0.008333	-0.000001	3.000000																							

$	11-Dec-2018	00:39:29.732	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.060000	126.211770	28.700000	173.500000																																

$	11-Dec-2018	00:39:27.422	Pre-Mission Delay	SBE41 Message						   -0.11  	-0.110000	-0.116930	0.000019	0.016667	0.011667	-0.000004	3.000000																							

$	11-Dec-2018	00:39:30.364	Pre-Mission Delay	SBE41 Message						   -0.12  	-0.120000	-0.108109	0.000001	0.003333	0.010000	-0.000019	3.000000																							

$	11-Dec-2018	00:39:30.857	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.205146	28.700000	173.500000																																

$	11-Dec-2018	00:39:31.702	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.195759	28.700000	173.500000																																

$	11-Dec-2018	00:39:32.800	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.204893	28.700000	173.500000																																

$	11-Dec-2018	00:39:33.383	Pre-Mission Delay	SBE41 Message						   -0.13  	-0.130000	-0.092640	-0.000279	0.003333	0.003333	-0.000052	3.000000																							

$	11-Dec-2018	00:39:33.924	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	126.219638	28.700000	173.500000																																

$	11-Dec-2018	00:39:34.801	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	126.214765	28.700000	173.500000																																

$	11-Dec-2018	00:39:35.898	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	126.216762	28.700000	173.500000																																

$	11-Dec-2018	00:39:36.894	Pre-Mission Delay	State Timed Out

$	11-Dec-2018	00:39:36.899	Surface Ops	State Entry

$	11-Dec-2018	00:39:37.005	Surface Ops	Powering up Iridium Modem

$	11-Dec-2018	00:39:47.001	Surface Ops	Starting valve close

$	11-Dec-2018	00:39:47.005	Surface Ops	Sending Optode Do Sample

$	11-Dec-2018	00:39:47.106	Surface Ops	Sending Optode Wakeup

$	11-Dec-2018	00:39:47.709	Surface Ops	Sending SBDD2 cmd

$	11-Dec-2018	00:39:36.364	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.079859	-0.001141	-0.003333	0.000000	-0.000098	3.000000																							

$	11-Dec-2018	00:39:48.162	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.204163	28.700000	173.500000																																

$	11-Dec-2018	00:39:48.175	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:11.2526148

$	11-Dec-2018	00:39:39.364	Surface Ops	SBE41 Message						   -0.11  	-0.110000	-0.081389	-0.002454	-0.003333	-0.003333	-0.000141	3.000000																							

$	11-Dec-2018	00:39:40.120	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:48.611	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:40.122	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:48.825	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:41.121	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:49.040	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:41.123	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:49.252	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:42.123	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:49.466	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:49.770	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.110000	126.211300	28.700000	173.500000																																

$	11-Dec-2018	00:39:49.783	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5037063

$	11-Dec-2018	00:39:42.125	Surface Ops	A3LA Message																																			0  	

$	11-Dec-2018	00:39:50.093	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	11-Dec-2018	00:39:42.126	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:50.305	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:42.128	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:50.518	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:42.363	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.096117	-0.003342	0.003333	0.000000	-0.000163	3.000000																							

$	11-Dec-2018	00:39:43.122	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:50.853	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:43.130	Surface Ops	A3LA Message																																			300125060561320  	

$	11-Dec-2018	00:39:51.070	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->300125060561320  <--  

$	11-Dec-2018	00:39:43.132	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:51.282	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:43.134	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:51.496	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:44.124	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:51.707	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:44.125	Surface Ops	A3LA Message																																			0  	

$	11-Dec-2018	00:39:51.921	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	11-Dec-2018	00:39:44.126	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:52.135	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:44.129	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:52.347	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:45.124	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:52.561	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:45.126	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:52.772	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:53.096	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.220599	28.700000	173.500000																																

$	11-Dec-2018	00:39:53.208	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.2233069

$	11-Dec-2018	00:39:45.364	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.111690	-0.002863	0.000000	0.001667	-0.000164	3.000000																							

$	11-Dec-2018	00:39:46.125	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:53.543	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:46.136	Surface Ops	A3LA Message																																			8988169234000597401  	

$	11-Dec-2018	00:39:53.757	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->8988169234000597401  <--  

$	11-Dec-2018	00:39:46.137	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:53.968	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:46.139	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:54.185	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:47.830	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:54.397	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:47.850	Surface Ops	A3LA Message																																			0  	

$	11-Dec-2018	00:39:54.609	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	11-Dec-2018	00:39:47.850	Surface Ops	A3LA Message																																			  	

$	11-Dec-2018	00:39:54.822	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	11-Dec-2018	00:39:47.850	Surface Ops	A3LA Message																																			OK  	

$	11-Dec-2018	00:39:55.035	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	11-Dec-2018	00:39:48.503	Surface Ops	SBE41 Message						   -0.06  	-0.060000	-0.119262	-0.000930	-0.020000	-0.010000	-0.000155	3.000000																							

$	11-Dec-2018	00:39:48.823	Surface Ops	Optode Message																												4330,1532,262.276,22.727,29.164,29.095,36.213,7.118,548.2,469.7,103.0  								

$	11-Dec-2018	00:39:48.823	Surface Ops	Optode Message																												#  								

$	11-Dec-2018	00:39:55.593	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.060000	126.223713	28.700000	173.500000																																

$	11-Dec-2018	00:39:55.608	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3941726

$	11-Dec-2018	00:39:51.495	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.119505	0.001527	0.013333	-0.003333	-0.000146	3.000000																							

$	11-Dec-2018	00:39:54.500	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.116601	0.003190	0.000000	0.006667	-0.000140	3.000000																							

$	11-Dec-2018	00:39:56.260	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	126.214936	28.700000	173.500000																																

$	11-Dec-2018	00:39:56.913	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	126.219399	28.700000	173.500000																																

$	11-Dec-2018	00:39:57.809	Surface Ops	Processing Console Command: $go

$	11-Dec-2018	00:39:57.495	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.111331	0.003241	0.006667	0.003333	-0.000141	3.000000																							

$	11-Dec-2018	00:39:58.144	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	126.207158	28.700000	173.500000																																

$	11-Dec-2018	00:39:59.011	Surface Ops	Normal State Exit

$	11-Dec-2018	00:39:59.113	Surface Ops	Closing old engr log file: \SD\data\2018-12-11T0-36-55.eng
