$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	12-Dec-2018	17:05:51.015	Surface Ops	Opened new engr log file: \SD\data\2018-12-12T17-5-49.eng

$	12-Dec-2018	17:05:51.021	Surface Ops	Profile Number = 0

$	12-Dec-2018	17:05:51.698	Surface Ops	Writing Header to Sci File

$	12-Dec-2018	17:05:51.817	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.190000	154.457577	32.325000	153.000000																																

$	12-Dec-2018	17:05:51.830	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1146912

$	12-Dec-2018	17:05:52.030	AB Dec Buoycy Fast	State Entry

$	12-Dec-2018	17:05:52.137	AB Dec Buoycy Fast	Decreasing Buoyancy to pressure = 0.29999999999999999 at 200000 cps

$	12-Dec-2018	17:05:52.144	AB Dec Buoycy Fast	Initializing SBE 41 LPF

$	12-Dec-2018	17:05:52.349	AB Dec Buoycy Fast	Waiting 00:00:15 for sampling to finish before ABRetractFast

$	12-Dec-2018	17:05:50.383	AB Dec Buoycy Fast	SBE41 Message						   -0.12  	-0.120000	0.189997	-0.000000	0.103333	0.051667	0.000000	3.000000																							

$	12-Dec-2018	17:05:52.779	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	154.434651	32.325000	153.000000																																

$	12-Dec-2018	17:05:53.233	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	154.442400	32.325000	153.000000																																

$	12-Dec-2018	17:05:53.606	AB Dec Buoycy Fast	Unparsed SBE41 Message						S>  																														

$	12-Dec-2018	17:05:54.349	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	154.466696	32.325000	153.000000																																

$	12-Dec-2018	17:05:55.232	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	154.456027	32.325000	153.000000																																

$	12-Dec-2018	17:05:56.233	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	154.447824	32.325000	153.000000																																

$	12-Dec-2018	17:05:56.072	AB Dec Buoycy Fast	SBE41 Message						   -0.09  	-0.090000	0.189341	-0.000008	-0.010000	0.046667	0.000001	3.000000																							

$	12-Dec-2018	17:05:57.357	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.447891	32.325000	153.000000																																

$	12-Dec-2018	17:05:58.233	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.445924	32.325000	153.000000																																

$	12-Dec-2018	17:05:59.233	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.451177	32.325000	153.000000																																

$	12-Dec-2018	17:05:59.072	AB Dec Buoycy Fast	SBE41 Message						   -0.10  	-0.100000	0.181960	-0.000069	0.003333	-0.003333	0.000010	3.000000																							

$	12-Dec-2018	17:06:00.358	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	154.459402	32.325000	153.000000																																

$	12-Dec-2018	17:06:01.235	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	154.465556	32.325000	153.000000																																

$	12-Dec-2018	17:06:02.235	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	154.472381	32.325000	153.000000																																

$	12-Dec-2018	17:06:02.072	AB Dec Buoycy Fast	SBE41 Message						   -0.08  	-0.080000	0.151002	-0.000113	-0.006667	-0.001667	0.000057	3.000000																							

$	12-Dec-2018	17:06:03.358	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	154.455617	32.325000	153.000000																																

$	12-Dec-2018	17:06:04.235	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	154.476546	32.325000	153.000000																																

$	12-Dec-2018	17:06:05.073	AB Dec Buoycy Fast	SBE41 Message						   -0.09  	-0.090000	0.083816	0.000627	0.003333	-0.001667	0.000183	3.000000																							

$	12-Dec-2018	17:06:05.359	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.449165	32.325000	153.000000																																

$	12-Dec-2018	17:06:06.332	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.448673	32.325000	153.000000																																

$	12-Dec-2018	17:06:07.333	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.453300	32.325000	153.000000																																

$	12-Dec-2018	17:06:08.072	AB Dec Buoycy Fast	SBE41 Message						   -0.09  	-0.090000	-0.000341	0.003663	0.000000	0.001667	0.000407	3.000000																							

$	12-Dec-2018	17:06:08.360	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.464647	32.325000	153.000000																																

$	12-Dec-2018	17:06:09.131	AB Dec Buoycy Fast	Disabling unneeded power

$	12-Dec-2018	17:06:09.135	AB Dec Buoycy Fast	Powering down MSC

$	12-Dec-2018	17:06:09.237	AB Dec Buoycy Fast	Powering down GPS

$	12-Dec-2018	17:06:09.339	AB Dec Buoycy Fast	Powering down MSC

$	12-Dec-2018	17:06:09.441	AB Dec Buoycy Fast	Powering down FLBB

$	12-Dec-2018	17:06:09.542	AB Dec Buoycy Fast	Powering down 4330 Optode

$	12-Dec-2018	17:06:09.644	AB Dec Buoycy Fast	Powering down OCR504

$	12-Dec-2018	17:06:09.745	AB Dec Buoycy Fast	Powering down Bluetooth

$	12-Dec-2018	17:06:12.848	AB Dec Buoycy Fast	Powering down BT Module

$	12-Dec-2018	17:06:11.072	AB Dec Buoycy Fast	SBE41 Message						   -0.08  	-0.080000	-0.062105	0.009554	-0.003333	-0.001667	0.000695	3.000000																							

$	12-Dec-2018	17:06:13.179	AB Dec Buoycy Fast	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	154.458188	32.325000	153.000000																																

$	12-Dec-2018	17:06:13.192	AB Dec Buoycy Fast	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.0608727

$	12-Dec-2018	17:06:13.295	AB Dec Buoycy Fast	Starting valve open

$	12-Dec-2018	17:06:14.071	AB Dec Buoycy Fast	SBE41 Message						   -0.09  	-0.090000	-0.086379	0.016325	0.003333	0.000000	0.001000	3.000000																							

$	12-Dec-2018	17:06:15.328	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.487669	32.325000	153.000000																																

$	12-Dec-2018	17:06:15.340	AB Dec Buoycy Fast	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0447075

$	12-Dec-2018	17:06:15.645	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.497497	32.325000	153.000000																																

$	12-Dec-2018	17:06:16.645	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.493161	32.325000	153.000000																																

$	12-Dec-2018	17:06:17.072	AB Dec Buoycy Fast	SBE41 Message						   -0.09  	-0.090000	-0.089229	0.020575	0.000000	0.001667	0.001292	3.000000																							

$	12-Dec-2018	17:06:17.674	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.514410	32.325000	153.000000																																

$	12-Dec-2018	17:06:18.646	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.504023	32.325000	153.000000																																

$	12-Dec-2018	17:06:19.645	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	154.829808	32.325000	153.000000																																

$	12-Dec-2018	17:06:20.072	AB Dec Buoycy Fast	SBE41 Message						   -0.08  	-0.080000	-0.087801	0.020036	-0.003333	-0.001667	0.001565	3.000000																							

$	12-Dec-2018	17:06:20.672	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	155.106232	32.325000	153.000000																																

$	12-Dec-2018	17:06:21.646	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	155.341588	32.325000	153.000000																																

$	12-Dec-2018	17:06:22.645	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	155.531295	32.325000	153.000000																																

$	12-Dec-2018	17:06:23.072	AB Dec Buoycy Fast	SBE41 Message						   -0.08  	-0.080000	-0.086938	0.014962	0.000000	-0.001667	0.001821	3.000000																							

$	12-Dec-2018	17:06:23.674	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	155.753694	32.325000	153.000000																																

$	12-Dec-2018	17:06:24.646	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	155.999653	32.325000	153.000000																																

$	12-Dec-2018	17:06:25.645	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	156.181984	32.325000	153.000000																																

$	12-Dec-2018	17:06:26.072	AB Dec Buoycy Fast	SBE41 Message						    1.19  	1.190000	-0.086593	0.007967	-0.423333	-0.211667	0.002060	3.000000																							

$	12-Dec-2018	17:06:26.672	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.190000	156.371683	32.325000	153.000000																																

$	12-Dec-2018	17:06:27.443	AB Dec Buoycy Fast	Throwing away bad pressure in checkForJustNegative

$	12-Dec-2018	17:06:27.650	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.190000	156.545095	32.325000	153.000000																																

$	12-Dec-2018	17:06:28.444	AB Dec Buoycy Fast	Throwing away bad pressure in checkForJustNegative

$	12-Dec-2018	17:06:28.748	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.190000	156.836316	32.325000	153.000000																																

$	12-Dec-2018	17:06:29.443	AB Dec Buoycy Fast	Throwing away bad pressure in checkForJustNegative

$	12-Dec-2018	17:06:29.072	AB Dec Buoycy Fast	SBE41 Message						    1.08  	1.080000	-0.083738	0.002442	0.036667	-0.193333	0.002278	3.000000																							

$	12-Dec-2018	17:06:29.872	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.080000	157.009110	32.325000	153.000000																																

$	12-Dec-2018	17:06:30.444	AB Dec Buoycy Fast	Throwing away bad pressure in checkForJustNegative

$	12-Dec-2018	17:06:30.748	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.080000	157.297179	32.325000	153.000000																																

$	12-Dec-2018	17:06:31.444	AB Dec Buoycy Fast	Throwing away bad pressure in checkForJustNegative

$	12-Dec-2018	17:06:31.651	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	1.080000	157.456346	32.325000	153.000000																																

$	12-Dec-2018	17:06:32.444	AB Dec Buoycy Fast	Throwing away bad pressure in checkForJustNegative

$	12-Dec-2018	17:06:32.071	AB Dec Buoycy Fast	SBE41 Message						    0.29  	0.290000	-0.052478	0.000205	0.263333	0.150000	0.002439	3.000000																							

$	12-Dec-2018	17:06:32.775	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.290000	157.641239	32.325000	153.000000																																

$	12-Dec-2018	17:06:33.647	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.290000	157.854870	32.325000	153.000000																																

$	12-Dec-2018	17:06:34.647	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.290000	158.052839	32.325000	153.000000																																

$	12-Dec-2018	17:06:35.073	AB Dec Buoycy Fast	SBE41 Message						    0.28  	0.280000	0.075033	0.000025	0.003333	0.133333	0.002425	3.000000																							

$	12-Dec-2018	17:06:35.674	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.280000	158.274926	32.325000	153.000000																																

$	12-Dec-2018	17:06:36.648	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.280000	158.507854	32.325000	153.000000																																

$	12-Dec-2018	17:06:37.648	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.280000	158.711396	32.325000	153.000000																																

$	12-Dec-2018	17:06:38.072	AB Dec Buoycy Fast	SBE41 Message						    0.27  	0.270000	0.333835	-0.003026	0.003333	0.003333	0.002077	3.000000																							

$	12-Dec-2018	17:06:38.675	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.270000	158.843920	32.325000	153.000000																																

$	12-Dec-2018	17:06:39.648	AB Dec Buoycy Fast	RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.270000	159.094080	32.325000	153.000000																																
