$ Date Time State Comment Pressure Bel Pos Batt Volt Batt Amps CTD Temp CTD Sal Raw Press LPF Press LPF Vel Diff Vel Diff 2 Vel Slope of LPF Press. CTD Sample Period LPS331 Press LPS311 Temp SHT21 Humid SHT21 Temp PID SP PID PV PID Y1 PID Y2 PID I PID v PID u PID uCPS PID h FLBB Topt Tphase Rphase NO3 pH OCR GPS Irid Modem $ 12-Dec-2018 19:35:08.042 Surface Ops Opened new engr log file: \SD\data\2018-12-12T19-35-6.eng $ 12-Dec-2018 19:35:08.048 Surface Ops Profile Number = 0 $ 12-Dec-2018 19:35:08.728 Surface Ops Writing Header to Sci File $ 12-Dec-2018 19:35:08.844 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 151.023686 29.800000 165.000000 $ 12-Dec-2018 19:35:08.955 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.2310760 $ 12-Dec-2018 19:35:08.961 AB Dec Buoycy Fast State Entry $ 12-Dec-2018 19:35:09.165 AB Dec Buoycy Fast Decreasing Buoyancy to pressure = 0.29999999999999999 at 200000 cps $ 12-Dec-2018 19:35:09.175 AB Dec Buoycy Fast Initializing SBE 41 LPF $ 12-Dec-2018 19:35:09.380 AB Dec Buoycy Fast Waiting 00:00:15 for sampling to finish before ABRetractFast $ 12-Dec-2018 19:35:07.419 AB Dec Buoycy Fast SBE41 Message -0.13 -0.130000 -0.070001 -0.000000 0.020000 0.010000 -0.000000 3.000000 $ 12-Dec-2018 19:35:09.811 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 151.010998 29.800000 165.000000 $ 12-Dec-2018 19:35:10.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 151.013471 29.800000 165.000000 $ 12-Dec-2018 19:35:10.418 AB Dec Buoycy Fast SBE41 Message 0.50 0.500000 -0.070122 -0.000001 -0.210000 -0.095000 0.000000 3.000000 $ 12-Dec-2018 19:35:11.289 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.500000 151.017725 29.800000 165.000000 $ 12-Dec-2018 19:35:12.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.500000 151.026204 29.800000 165.000000 $ 12-Dec-2018 19:35:13.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.500000 151.018865 29.800000 165.000000 $ 12-Dec-2018 19:35:13.417 AB Dec Buoycy Fast SBE41 Message 0.07 0.070000 -0.070233 0.000002 0.143333 -0.033333 0.000000 3.000000 $ 12-Dec-2018 19:35:14.193 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.070000 151.043788 29.800000 165.000000 $ 12-Dec-2018 19:35:15.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.070000 151.019201 29.800000 165.000000 $ 12-Dec-2018 19:35:16.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.070000 151.023276 29.800000 165.000000 $ 12-Dec-2018 19:35:16.417 AB Dec Buoycy Fast SBE41 Message 0.03 0.030000 -0.062141 0.000107 0.013333 0.078333 -0.000009 3.000000 $ 12-Dec-2018 19:35:17.194 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.030000 151.013091 29.800000 165.000000 $ 12-Dec-2018 19:35:18.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.030000 151.031077 29.800000 165.000000 $ 12-Dec-2018 19:35:19.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.030000 151.031896 29.800000 165.000000 $ 12-Dec-2018 19:35:19.418 AB Dec Buoycy Fast SBE41 Message 0.59 0.590000 -0.021771 0.000266 -0.186667 -0.086667 -0.000066 3.000000 $ 12-Dec-2018 19:35:20.289 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.590000 151.035786 29.800000 165.000000 $ 12-Dec-2018 19:35:21.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.590000 151.016489 29.800000 165.000000 $ 12-Dec-2018 19:35:22.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.590000 151.049070 29.800000 165.000000 $ 12-Dec-2018 19:35:22.418 AB Dec Buoycy Fast SBE41 Message 1.00 1.000000 0.059418 -0.000695 -0.136667 -0.161667 -0.000219 3.000000 $ 12-Dec-2018 19:35:23.292 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.000000 151.025318 29.800000 165.000000 $ 12-Dec-2018 19:35:24.166 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.000000 151.037179 29.800000 165.000000 $ 12-Dec-2018 19:35:25.165 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.000000 151.044719 29.800000 165.000000 $ 12-Dec-2018 19:35:25.962 AB Dec Buoycy Fast Disabling unneeded power $ 12-Dec-2018 19:35:25.966 AB Dec Buoycy Fast Powering down MSC $ 12-Dec-2018 19:35:26.068 AB Dec Buoycy Fast Powering down GPS $ 12-Dec-2018 19:35:26.170 AB Dec Buoycy Fast Powering down MSC $ 12-Dec-2018 19:35:26.272 AB Dec Buoycy Fast Powering down FLBB $ 12-Dec-2018 19:35:26.374 AB Dec Buoycy Fast Powering down 4330 Optode $ 12-Dec-2018 19:35:26.476 AB Dec Buoycy Fast Powering down OCR504 $ 12-Dec-2018 19:35:26.578 AB Dec Buoycy Fast Powering down Bluetooth $ 12-Dec-2018 19:35:29.680 AB Dec Buoycy Fast Powering down BT Module $ 12-Dec-2018 19:35:25.417 AB Dec Buoycy Fast SBE41 Message 1.14 1.140000 0.142589 -0.004674 -0.046667 -0.091667 -0.000468 3.000000 $ 12-Dec-2018 19:35:28.419 AB Dec Buoycy Fast SBE41 Message 0.83 0.830000 0.211754 -0.011212 0.103333 0.028333 -0.000792 3.000000 $ 12-Dec-2018 19:35:30.234 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.830000 151.013523 29.800000 165.000000 $ 12-Dec-2018 19:35:30.345 AB Dec Buoycy Fast ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.3828623 $ 12-Dec-2018 19:35:30.448 AB Dec Buoycy Fast Starting valve open $ 12-Dec-2018 19:35:31.418 AB Dec Buoycy Fast SBE41 Message 0.27 0.270000 0.336934 -0.017416 0.186667 0.145000 -0.001259 3.000000 $ 12-Dec-2018 19:35:32.382 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.270000 151.041634 29.800000 165.000000 $ 12-Dec-2018 19:35:32.494 AB Dec Buoycy Fast ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1428094 $ 12-Dec-2018 19:35:32.801 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.270000 151.046924 29.800000 165.000000 $ 12-Dec-2018 19:35:33.702 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.270000 151.057981 29.800000 165.000000 $ 12-Dec-2018 19:35:34.419 AB Dec Buoycy Fast SBE41 Message 0.24 0.240000 0.560559 -0.023137 0.010000 0.098333 -0.001986 3.000000 $ 12-Dec-2018 19:35:34.731 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.240000 151.056200 29.800000 165.000000 $ 12-Dec-2018 19:35:35.703 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.240000 151.061803 29.800000 165.000000 $ 12-Dec-2018 19:35:36.702 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.240000 151.251003 29.800000 165.000000 $ 12-Dec-2018 19:35:37.417 AB Dec Buoycy Fast SBE41 Message 0.22 0.220000 0.780022 -0.032044 0.006667 0.008333 -0.002957 3.000000 $ 12-Dec-2018 19:35:37.730 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 151.517622 29.800000 165.000000 $ 12-Dec-2018 19:35:38.703 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 151.730061 29.800000 165.000000 $ 12-Dec-2018 19:35:39.703 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 151.911438 29.800000 165.000000 $ 12-Dec-2018 19:35:40.418 AB Dec Buoycy Fast SBE41 Message 0.22 0.220000 0.840805 -0.044930 0.000000 0.003333 -0.003961 3.000000 $ 12-Dec-2018 19:35:40.828 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 152.138226 29.800000 165.000000 $ 12-Dec-2018 19:35:41.704 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 152.359918 29.800000 165.000000 $ 12-Dec-2018 19:35:42.704 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 152.574584 29.800000 165.000000 $ 12-Dec-2018 19:35:43.418 AB Dec Buoycy Fast SBE41 Message 0.22 0.220000 0.707206 -0.055048 0.000000 0.000000 -0.004744 3.000000 $ 12-Dec-2018 19:35:43.732 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 152.750991 29.800000 165.000000 $ 12-Dec-2018 19:35:44.705 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 152.925983 29.800000 165.000000 $ 12-Dec-2018 19:35:45.705 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.220000 153.150611 29.800000 165.000000 $ 12-Dec-2018 19:35:46.419 AB Dec Buoycy Fast SBE41 Message 1.21 1.210000 0.490412 -0.051890 -0.330000 -0.165000 -0.005201 3.000000 $ 12-Dec-2018 19:35:46.733 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.210000 153.362043 29.800000 165.000000 $ 12-Dec-2018 19:35:47.705 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.210000 153.583668 29.800000 165.000000 $ 12-Dec-2018 19:35:48.706 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.210000 153.805844 29.800000 165.000000 $ 12-Dec-2018 19:35:49.513 AB Dec Buoycy Fast AB Decreasing Buoyancy Fast Exiting: Depth > pressure threshold $ 12-Dec-2018 19:35:49.418 AB Dec Buoycy Fast SBE41 Message 1.22 1.220000 0.325275 -0.029706 -0.003333 -0.166667 -0.005407 3.000000 $ 12-Dec-2018 19:35:49.846 AB Dec Buoycy Fast Normal State Exit $ 12-Dec-2018 19:35:49.851 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.220000 153.967142 29.800000 165.000000 $ 12-Dec-2018 19:35:50.503 Descend State Entry $ 12-Dec-2018 19:35:50.607 Descend Starting valve open $ 12-Dec-2018 19:35:50.916 Descend RecMode true, PID On, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.220000 154.185310 29.800000 165.000000 $ 12-Dec-2018 19:35:51.706 Descend RecMode true, PID On, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.220000 154.225238 29.800000 165.000000 $ 12-Dec-2018 19:35:52.418 Descend Vel PID Values -0.200000 0.010000 0.001011 0.001011 -0.000965 -16.350562 -16.350562 -133943.000000 3.000000 $ 12-Dec-2018 19:35:52.418 Descend SBE41 Message 1.19 1.190000 0.272130 0.005588 0.010000 0.003333 -0.005517 3.000000 $ 12-Dec-2018 19:35:53.045 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.190000 154.238924 29.800000 165.000000 $ 12-Dec-2018 19:35:53.705 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.190000 154.249251 29.800000 165.000000 $ 12-Dec-2018 19:35:54.706 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.190000 154.401094 29.800000 165.000000 $ 12-Dec-2018 19:35:55.419 Descend Vel PID Values -0.200000 0.210000 0.022713 0.021702 -0.002034 -23.605157 -23.605157 -193373.000000 3.000000 $ 12-Dec-2018 19:35:55.419 Descend SBE41 Message 0.56 0.560000 0.351712 0.037302 0.210000 0.110000 -0.005706 3.000000 $ 12-Dec-2018 19:35:56.044 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.560000 154.529564 29.800000 165.000000 $ 12-Dec-2018 19:35:56.706 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.560000 154.776804 29.800000 165.000000 $ 12-Dec-2018 19:35:57.722 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.560000 154.905826 29.800000 165.000000 $ 12-Dec-2018 19:35:58.419 Descend Vel PID Values -0.200000 0.003333 0.032945 0.010232 -0.003152 -21.366268 -21.366268 -175032.000000 3.000000 $ 12-Dec-2018 19:35:58.419 Descend SBE41 Message 0.55 0.550000 0.570442 0.047862 0.003333 0.106667 -0.006152 3.000000 $ 12-Dec-2018 19:35:59.060 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 155.144177 29.800000 165.000000 $ 12-Dec-2018 19:35:59.723 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 155.373737 29.800000 165.000000 $ 12-Dec-2018 19:36:00.723 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 155.583009 29.800000 165.000000 $ 12-Dec-2018 19:36:01.417 Descend Vel PID Values -0.200000 0.000000 0.035362 0.002417 -0.004282 -19.476644 -19.476644 -159552.000000 3.000000 $ 12-Dec-2018 19:36:01.417 Descend SBE41 Message 0.55 0.550000 0.842556 0.030180 0.000000 0.001667 -0.006912 3.000000 $ 12-Dec-2018 19:36:02.063 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 155.638561 29.800000 165.000000 $ 12-Dec-2018 19:36:02.723 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 155.896507 29.800000 165.000000 $ 12-Dec-2018 19:36:03.724 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 155.985884 29.800000 165.000000 $ 12-Dec-2018 19:36:04.417 Descend Vel PID Values -0.200000 0.000000 0.033144 -0.002218 -0.005401 -18.064308 -18.064308 -147982.000000 3.000000 $ 12-Dec-2018 19:36:04.417 Descend SBE41 Message 0.55 0.550000 0.997788 -0.007203 0.000000 0.000000 -0.007814 3.000000 $ 12-Dec-2018 19:36:05.064 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 156.243578 29.800000 165.000000 $ 12-Dec-2018 19:36:05.724 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 156.368099 29.800000 165.000000 $ 12-Dec-2018 19:36:06.724 Descend PTH Message 796.760742 23.783333 55.275482 24.675676 $ 12-Dec-2018 19:36:06.928 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.550000 156.495281 29.400000 140.000000 $ 12-Dec-2018 19:36:07.510 Descend Vel PID Values -0.200000 0.210000 0.049782 0.016638 -0.006600 -24.424825 -24.424825 -200088.000000 3.000000 $ 12-Dec-2018 19:36:07.510 Descend SBE41 Message -0.08 -0.080000 0.949009 -0.044086 0.210000 0.105000 -0.008577 3.000000 $ 12-Dec-2018 19:36:08.067 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 156.639256 29.400000 140.000000 $ 12-Dec-2018 19:36:08.725 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 156.826422 29.400000 140.000000 $ 12-Dec-2018 19:36:09.724 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.080000 156.955883 29.400000 140.000000 $ 12-Dec-2018 19:36:10.418 Descend Vel PID Values -0.200000 -0.386667 0.014994 -0.034788 -0.007632 -7.929340 -7.929340 -64957.000000 3.000000 $ 12-Dec-2018 19:36:10.418 Descend SBE41 Message 1.08 1.080000 0.779778 -0.060699 -0.386667 -0.088333 -0.009043 3.000000 $ 12-Dec-2018 19:36:11.064 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.080000 157.211013 29.400000 140.000000 $ 12-Dec-2018 19:36:11.725 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.080000 157.469220 29.400000 140.000000 $ 12-Dec-2018 19:36:12.725 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.080000 157.460891 29.400000 140.000000 $ 12-Dec-2018 19:36:13.418 Descend Vel PID Values -0.200000 0.003333 -0.005729 -0.020723 -0.008564 -10.023193 -10.023193 -82109.000000 3.000000 $ 12-Dec-2018 19:36:13.418 Descend SBE41 Message 1.07 1.070000 0.621098 -0.049632 0.003333 -0.191667 -0.009237 3.000000 $ 12-Dec-2018 19:36:14.063 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.070000 157.504365 29.400000 140.000000 $ 12-Dec-2018 19:36:14.725 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.070000 157.571353 29.400000 140.000000 $ 12-Dec-2018 19:36:15.726 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.070000 157.705449 29.400000 140.000000 $ 12-Dec-2018 19:36:16.418 Descend Vel PID Values -0.200000 -0.346667 -0.051848 -0.046119 -0.009275 0.437659 0.437659 3585.000000 3.000000 $ 12-Dec-2018 19:36:16.418 Descend SBE41 Message 2.11 2.110000 0.517322 -0.018322 -0.346667 -0.171667 -0.009242 3.000000 $ 12-Dec-2018 19:36:17.067 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.110000 157.765396 29.400000 140.000000 $ 12-Dec-2018 19:36:17.727 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.110000 157.851674 29.400000 140.000000 $ 12-Dec-2018 19:36:18.727 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.110000 157.871172 29.400000 140.000000 $ 12-Dec-2018 19:36:19.418 Descend Vel PID Values -0.200000 -0.106667 -0.083301 -0.031453 -0.009836 -0.957732 -0.957732 -7845.000000 3.000000 $ 12-Dec-2018 19:36:19.418 Descend SBE41 Message 2.43 2.430000 0.479168 0.017255 -0.106667 -0.226667 -0.009153 3.000000 $ 12-Dec-2018 19:36:20.068 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.430000 157.863498 29.400000 140.000000 $ 12-Dec-2018 19:36:20.728 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.430000 157.860443 29.400000 140.000000 $ 12-Dec-2018 19:36:21.728 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.430000 157.853611 29.400000 140.000000 $ 12-Dec-2018 19:36:22.417 Descend Vel PID Values -0.200000 -0.266667 -0.119514 -0.036213 -0.010222 3.208022 3.208022 26280.000000 3.000000 $ 12-Dec-2018 19:36:22.417 Descend SBE41 Message 3.23 3.230000 0.580697 0.040653 -0.266667 -0.186667 -0.009158 3.000000 $ 12-Dec-2018 19:36:23.069 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.230000 157.888196 29.400000 140.000000 $ 12-Dec-2018 19:36:23.728 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.230000 157.885097 29.400000 140.000000 $ 12-Dec-2018 19:36:24.728 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.230000 157.889612 29.400000 140.000000 $ 12-Dec-2018 19:36:25.419 Descend Vel PID Values -0.200000 -0.173333 -0.145300 -0.025787 -0.010484 2.490276 2.490276 20400.000000 3.000000 $ 12-Dec-2018 19:36:25.419 Descend SBE41 Message 3.75 3.750000 0.889811 0.041226 -0.173333 -0.220000 -0.009523 3.000000 $ 12-Dec-2018 19:36:26.066 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.750000 157.898471 29.400000 140.000000 $ 12-Dec-2018 19:36:26.728 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.750000 157.901883 29.400000 140.000000 $ 12-Dec-2018 19:36:27.729 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.750000 157.907046 29.400000 140.000000 $ 12-Dec-2018 19:36:28.417 Descend Vel PID Values -0.200000 -0.183333 -0.163633 -0.018333 -0.010659 1.968977 1.968977 16129.000000 3.000000 $ 12-Dec-2018 19:36:28.417 Descend SBE41 Message 4.30 4.300000 1.372699 0.017702 -0.183333 -0.178333 -0.010452 3.000000 $ 12-Dec-2018 19:36:29.070 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.300000 157.901146 29.400000 140.000000 $ 12-Dec-2018 19:36:29.730 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.300000 157.917313 29.400000 140.000000 $ 12-Dec-2018 19:36:30.730 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.300000 157.898456 29.400000 140.000000 $ 12-Dec-2018 19:36:31.419 Descend Vel PID Values -0.200000 -0.210000 -0.178622 -0.014988 -0.010762 2.275909 2.275909 18644.000000 3.000000 $ 12-Dec-2018 19:36:31.419 Descend SBE41 Message 4.93 4.930000 1.944626 -0.023584 -0.210000 -0.196667 -0.012025 3.000000 $ 12-Dec-2018 19:36:32.071 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.930000 157.906838 29.400000 140.000000 $ 12-Dec-2018 19:36:32.730 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.930000 157.893658 29.400000 140.000000 $ 12-Dec-2018 19:36:33.730 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.930000 157.923132 29.400000 140.000000 $ 12-Dec-2018 19:36:34.418 Descend Vel PID Values -0.200000 -0.210000 -0.190215 -0.011593 -0.010809 2.298015 2.298015 18825.000000 3.000000 $ 12-Dec-2018 19:36:34.418 Descend SBE41 Message 5.56 5.560000 2.546860 -0.074177 -0.210000 -0.210000 -0.014233 3.000000 $ 12-Dec-2018 19:36:35.071 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 5.560000 157.903053 29.400000 140.000000 $ 12-Dec-2018 19:36:35.731 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 5.560000 157.914370 29.400000 140.000000 $ 12-Dec-2018 19:36:36.731 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 5.560000 157.929562 29.400000 140.000000 $ 12-Dec-2018 19:36:37.419 Descend Vel PID Values -0.200000 -0.203333 -0.198055 -0.007840 -0.010818 1.924165 1.924165 15762.000000 3.000000 $ 12-Dec-2018 19:36:37.419 Descend SBE41 Message 6.17 6.170000 3.150952 -0.125595 -0.203333 -0.206667 -0.017026 3.000000 $ 12-Dec-2018 19:36:38.069 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.170000 157.898873 29.400000 140.000000 $ 12-Dec-2018 19:36:38.731 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.170000 157.904826 29.400000 140.000000 $ 12-Dec-2018 19:36:39.732 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.170000 157.915786 29.400000 140.000000 $ 12-Dec-2018 19:36:40.417 Descend Vel PID Values -0.200000 -0.213333 -0.204004 -0.005949 -0.010799 1.896008 1.896008 15532.000000 3.000000 $ 12-Dec-2018 19:36:40.417 Descend SBE41 Message 6.81 6.810000 3.746018 -0.168208 -0.213333 -0.208333 -0.020341 3.000000 $ 12-Dec-2018 19:36:41.071 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.810000 157.911181 29.400000 140.000000 $ 12-Dec-2018 19:36:41.733 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.810000 157.915466 29.400000 140.000000 $ 12-Dec-2018 19:36:42.733 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.810000 157.925054 29.400000 140.000000 $ 12-Dec-2018 19:36:43.418 Descend Vel PID Values -0.200000 -0.253333 -0.212335 -0.008331 -0.010740 3.197505 3.197505 26193.000000 3.000000 $ 12-Dec-2018 19:36:43.418 Descend SBE41 Message 7.57 7.570000 4.338158 -0.194479 -0.253333 -0.233333 -0.024122 3.000000 $ 12-Dec-2018 19:36:44.073 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.570000 157.902211 29.400000 140.000000 $ 12-Dec-2018 19:36:44.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.570000 157.914355 29.400000 140.000000 $ 12-Dec-2018 19:36:45.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.570000 157.909662 29.400000 140.000000 $ 12-Dec-2018 19:36:46.418 Descend Vel PID Values -0.200000 -0.080000 -0.203633 0.008702 -0.010722 -2.040652 -2.040652 -16717.000000 3.000000 $ 12-Dec-2018 19:36:46.418 Descend SBE41 Message 7.81 7.810000 4.940747 -0.204888 -0.080000 -0.166667 -0.028329 3.000000 $ 12-Dec-2018 19:36:47.075 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.810000 157.895811 29.400000 140.000000 $ 12-Dec-2018 19:36:47.734 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.810000 157.889225 29.400000 140.000000 $ 12-Dec-2018 19:36:48.734 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.810000 157.889247 29.400000 140.000000 $ 12-Dec-2018 19:36:49.418 Descend Vel PID Values -0.200000 -0.306667 -0.209163 -0.005530 -0.010678 2.197097 2.197097 17998.000000 3.000000 $ 12-Dec-2018 19:36:49.418 Descend SBE41 Message 8.73 8.730000 5.559093 -0.206616 -0.306667 -0.193333 -0.032931 3.000000 $ 12-Dec-2018 19:36:50.072 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 8.730000 157.887347 29.400000 140.000000 $ 12-Dec-2018 19:36:50.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 8.730000 157.887369 29.400000 140.000000 $ 12-Dec-2018 19:36:51.735 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 8.730000 157.895766 29.400000 140.000000 $ 12-Dec-2018 19:36:52.418 Descend Vel PID Values -0.200000 -0.146667 -0.205950 0.003213 -0.010650 -0.391431 -0.391431 -3206.000000 3.000000 $ 12-Dec-2018 19:36:52.418 Descend SBE41 Message 9.17 9.170000 6.187892 -0.206473 -0.146667 -0.226667 -0.037887 3.000000 $ 12-Dec-2018 19:36:53.073 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.170000 157.891296 29.400000 140.000000 $ 12-Dec-2018 19:36:53.735 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.170000 157.886416 29.400000 140.000000 $ 12-Dec-2018 19:36:54.735 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.170000 157.883964 29.400000 140.000000 $ 12-Dec-2018 19:36:55.419 Descend Vel PID Values -0.200000 -0.186666 -0.202195 0.003755 -0.010639 -0.836378 -0.836378 -6851.000000 3.000000 $ 12-Dec-2018 19:36:55.419 Descend SBE41 Message 9.73 9.730000 6.812229 -0.207636 -0.186666 -0.166667 -0.043136 3.000000 $ 12-Dec-2018 19:36:56.075 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.730000 157.878824 29.400000 140.000000 $ 12-Dec-2018 19:36:56.735 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.730000 157.888800 29.400000 140.000000 $ 12-Dec-2018 19:36:57.735 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.730000 157.881841 29.400000 140.000000 $ 12-Dec-2018 19:36:58.419 Descend Vel PID Values -0.200000 -0.266667 -0.206605 -0.004410 -0.010607 1.693784 1.693784 13875.000000 3.000000 $ 12-Dec-2018 19:36:58.419 Descend SBE41 Message 10.53 10.530000 7.417120 -0.210318 -0.266667 -0.226667 -0.048601 3.000000 $ 12-Dec-2018 19:36:59.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 10.530000 157.871842 29.400000 140.000000 $ 12-Dec-2018 19:36:59.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 10.530000 157.884330 29.400000 140.000000 $ 12-Dec-2018 19:37:00.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 10.530000 157.903045 29.400000 140.000000 $ 12-Dec-2018 19:37:01.419 Descend Vel PID Values -0.200000 -0.203334 -0.208752 -0.002147 -0.010565 1.261997 1.261997 10338.000000 3.000000 $ 12-Dec-2018 19:37:01.419 Descend SBE41 Message 11.14 11.140000 8.008148 -0.212709 -0.203334 -0.235000 -0.054216 3.000000 $ 12-Dec-2018 19:37:02.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.140000 157.893613 29.400000 140.000000 $ 12-Dec-2018 19:37:02.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.140000 157.893106 29.400000 140.000000 $ 12-Dec-2018 19:37:03.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.140000 157.863110 29.400000 140.000000 $ 12-Dec-2018 19:37:04.419 Descend Vel PID Values -0.200000 -0.180000 -0.207050 0.001701 -0.010531 0.099738 0.099738 817.000000 3.000000 $ 12-Dec-2018 19:37:04.419 Descend SBE41 Message 11.68 11.680000 8.601992 -0.212913 -0.180000 -0.191667 -0.059938 3.000000 $ 12-Dec-2018 19:37:05.075 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.680000 157.892436 29.400000 140.000000 $ 12-Dec-2018 19:37:05.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.680000 157.887653 29.400000 140.000000 $ 12-Dec-2018 19:37:06.736 Descend PTH Message 800.547363 23.816667 55.023712 24.772202 $ 12-Dec-2018 19:37:06.938 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.680000 157.882772 29.675000 125.000000 $ 12-Dec-2018 19:37:07.523 Descend Vel PID Values -0.200000 -0.206667 -0.206056 0.000995 -0.010502 0.208671 0.208671 1709.000000 3.000000 $ 12-Dec-2018 19:37:07.523 Descend SBE41 Message 12.30 12.300000 9.206321 -0.210813 -0.206667 -0.193333 -0.066281 3.000000 $ 12-Dec-2018 19:37:08.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.300000 157.882445 29.675000 125.000000 $ 12-Dec-2018 19:37:08.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.300000 157.888897 29.675000 125.000000 $ 12-Dec-2018 19:37:09.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.300000 157.873854 29.675000 125.000000 $ 12-Dec-2018 19:37:10.419 Descend Vel PID Values -0.200000 -0.203333 -0.205222 0.000834 -0.010477 0.184789 0.184789 1513.000000 3.000000 $ 12-Dec-2018 19:37:10.419 Descend SBE41 Message 12.91 12.910000 9.827693 -0.207906 -0.203333 -0.205000 -0.072802 3.000000 $ 12-Dec-2018 19:37:11.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.910000 157.889567 29.675000 125.000000 $ 12-Dec-2018 19:37:11.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.910000 157.888219 29.675000 125.000000 $ 12-Dec-2018 19:37:12.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.910000 157.892123 29.675000 125.000000 $ 12-Dec-2018 19:37:13.420 Descend Vel PID Values -0.200000 -0.210000 -0.205236 -0.000015 -0.010452 0.412311 0.412311 3377.000000 3.000000 $ 12-Dec-2018 19:37:13.420 Descend SBE41 Message 13.54 13.540000 10.464180 -0.206379 -0.210000 -0.206667 -0.079480 3.000000 $ 12-Dec-2018 19:37:14.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 13.540000 157.879822 29.675000 125.000000 $ 12-Dec-2018 19:37:14.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 13.540000 157.879047 29.675000 125.000000 $ 12-Dec-2018 19:37:15.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 13.540000 157.883972 29.675000 125.000000 $ 12-Dec-2018 19:37:16.419 Descend Vel PID Values -0.200000 -0.196667 -0.204378 0.000858 -0.010431 0.110873 0.110873 908.000000 3.000000 $ 12-Dec-2018 19:37:16.419 Descend SBE41 Message 14.13 14.130000 11.093825 -0.207799 -0.196667 -0.203333 -0.086279 3.000000 $ 12-Dec-2018 19:37:17.077 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.130000 157.888062 29.675000 125.000000 $ 12-Dec-2018 19:37:17.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.130000 157.882884 29.675000 125.000000 $ 12-Dec-2018 19:37:18.735 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.130000 157.878108 29.675000 125.000000 $ 12-Dec-2018 19:37:19.420 Descend Vel PID Values -0.200000 -0.200000 -0.203453 0.000925 -0.010415 0.019144 0.019144 156.000000 3.000000 $ 12-Dec-2018 19:37:19.420 Descend SBE41 Message 14.73 14.730000 11.703960 -0.211326 -0.200000 -0.198333 -0.093175 3.000000 $ 12-Dec-2018 19:37:20.073 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.730000 157.891266 29.675000 125.000000 $ 12-Dec-2018 19:37:20.735 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.730000 157.885768 29.675000 125.000000 $ 12-Dec-2018 19:37:21.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.730000 157.881357 29.675000 125.000000 $ 12-Dec-2018 19:37:22.419 Descend Vel PID Values -0.200000 -0.213333 -0.203932 -0.000480 -0.010396 0.432049 0.432049 3539.000000 3.000000 $ 12-Dec-2018 19:37:22.419 Descend SBE41 Message 15.37 15.370000 12.307054 -0.214239 -0.213333 -0.206667 -0.100178 3.000000 $ 12-Dec-2018 19:37:23.073 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.370000 157.888517 29.675000 125.000000 $ 12-Dec-2018 19:37:23.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.370000 157.910608 29.675000 125.000000 $ 12-Dec-2018 19:37:24.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.370000 157.888867 29.675000 125.000000 $ 12-Dec-2018 19:37:25.418 Descend Vel PID Values -0.200000 -0.203333 -0.204141 -0.000209 -0.010376 0.376581 0.376581 3084.000000 3.000000 $ 12-Dec-2018 19:37:25.418 Descend SBE41 Message 15.98 15.980000 12.914867 -0.214834 -0.203333 -0.208333 -0.107263 3.000000 $ 12-Dec-2018 19:37:26.074 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.980000 157.883622 29.675000 125.000000 $ 12-Dec-2018 19:37:26.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.980000 157.890551 29.675000 125.000000 $ 12-Dec-2018 19:37:27.734 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.980000 157.890044 29.675000 125.000000 $ 12-Dec-2018 19:37:28.420 Descend Vel PID Values -0.200000 -0.193333 -0.203166 0.000976 -0.010361 -0.017298 -0.017298 -141.000000 3.000000 $ 12-Dec-2018 19:37:28.420 Descend SBE41 Message 16.56 16.559999 13.525219 -0.213447 -0.193333 -0.198333 -0.114383 3.000000 $ 12-Dec-2018 19:37:29.074 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 16.559999 157.898195 29.675000 125.000000 $ 12-Dec-2018 19:37:29.734 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 16.559999 157.891788 29.675000 125.000000 $ 12-Dec-2018 19:37:30.735 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 16.559999 157.880850 29.675000 125.000000 $ 12-Dec-2018 19:37:31.419 Descend Vel PID Values -0.200000 -0.203334 -0.202634 0.000531 -0.010348 0.058763 0.058763 481.000000 3.000000 $ 12-Dec-2018 19:37:31.419 Descend SBE41 Message 17.17 17.170000 14.134740 -0.211222 -0.203334 -0.198333 -0.121574 3.000000 $ 12-Dec-2018 19:37:32.075 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.170000 157.889202 29.675000 125.000000 $ 12-Dec-2018 19:37:32.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.170000 157.880373 29.675000 125.000000 $ 12-Dec-2018 19:37:33.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.170000 157.883726 29.675000 125.000000 $ 12-Dec-2018 19:37:34.418 Descend Vel PID Values -0.200000 -0.200000 -0.202070 0.000565 -0.010338 0.004620 0.004620 37.000000 3.000000 $ 12-Dec-2018 19:37:34.418 Descend SBE41 Message 17.77 17.770000 14.745427 -0.209494 -0.200000 -0.201667 -0.128934 3.000000 $ 12-Dec-2018 19:37:35.075 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.770000 157.885790 29.675000 125.000000 $ 12-Dec-2018 19:37:35.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.770000 157.882355 29.675000 125.000000 $ 12-Dec-2018 19:37:36.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.770000 157.882549 29.675000 125.000000 $ 12-Dec-2018 19:37:37.420 Descend Vel PID Values -0.200000 -0.210000 -0.202554 -0.000485 -0.010326 0.323239 0.323239 2647.000000 3.000000 $ 12-Dec-2018 19:37:37.420 Descend SBE41 Message 18.40 18.400000 15.357267 -0.209180 -0.210000 -0.205000 -0.136435 3.000000 $ 12-Dec-2018 19:37:38.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 18.400000 157.886110 29.675000 125.000000 $ 12-Dec-2018 19:37:38.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 18.400000 157.883726 29.675000 125.000000 $ 12-Dec-2018 19:37:39.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 18.400000 157.906279 29.675000 125.000000 $ 12-Dec-2018 19:37:40.419 Descend Vel PID Values -0.200000 -0.200000 -0.202568 -0.000014 -0.010313 0.198863 0.198863 1629.000000 3.000000 $ 12-Dec-2018 19:37:40.419 Descend SBE41 Message 19.00 19.000000 15.965610 -0.209823 -0.200000 -0.205000 -0.143844 3.000000 $ 12-Dec-2018 19:37:41.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.000000 157.908492 29.675000 125.000000 $ 12-Dec-2018 19:37:41.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.000000 157.879017 29.675000 125.000000 $ 12-Dec-2018 19:37:42.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.000000 157.875173 29.675000 125.000000 $ 12-Dec-2018 19:37:43.420 Descend Vel PID Values -0.200000 -0.240000 -0.206361 -0.003793 -0.010283 1.510075 1.510075 12370.000000 3.000000 $ 12-Dec-2018 19:37:43.420 Descend SBE41 Message 19.72 19.719999 16.569084 -0.210270 -0.240000 -0.220000 -0.150872 3.000000 $ 12-Dec-2018 19:37:44.077 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.719999 157.891914 29.675000 125.000000 $ 12-Dec-2018 19:37:44.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.719999 157.888219 29.675000 125.000000 $ 12-Dec-2018 19:37:45.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.719999 157.876484 29.675000 125.000000 $ 12-Dec-2018 19:37:46.419 Descend Vel PID Values -0.200000 -0.220000 -0.209871 -0.003510 -0.010236 1.715464 1.715464 14053.000000 3.000000 $ 12-Dec-2018 19:37:46.419 Descend SBE41 Message 20.38 20.379999 17.172780 -0.210072 -0.220000 -0.230000 -0.157366 3.000000 $ 12-Dec-2018 19:37:47.075 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.379999 157.862708 29.675000 125.000000 $ 12-Dec-2018 19:37:47.738 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.379999 157.872304 29.675000 125.000000 $ 12-Dec-2018 19:37:48.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.379999 157.873765 29.675000 125.000000 $ 12-Dec-2018 19:37:49.419 Descend Vel PID Values -0.200000 -0.176667 -0.208486 0.001386 -0.010195 0.299074 0.299074 2450.000000 3.000000 $ 12-Dec-2018 19:37:49.419 Descend SBE41 Message 20.91 20.910000 17.783109 -0.209493 -0.176667 -0.198333 -0.163351 3.000000 $ 12-Dec-2018 19:37:50.077 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.910000 157.875031 29.675000 125.000000 $ 12-Dec-2018 19:37:50.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.910000 157.848783 29.675000 125.000000 $ 12-Dec-2018 19:37:51.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.910000 157.859385 29.675000 125.000000 $ 12-Dec-2018 19:37:52.418 Descend Vel PID Values -0.200000 -0.196667 -0.206512 0.001974 -0.010164 -0.015560 -0.015560 -127.000000 3.000000 $ 12-Dec-2018 19:37:52.418 Descend SBE41 Message 21.50 21.500000 18.405965 -0.208911 -0.196667 -0.186667 -0.168935 3.000000 $ 12-Dec-2018 19:37:53.076 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 21.500000 157.839581 29.675000 125.000000 $ 12-Dec-2018 19:37:53.736 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 21.500000 157.830589 29.675000 125.000000 $ 12-Dec-2018 19:37:54.737 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 21.500000 157.829210 29.675000 125.000000 $ 12-Dec-2018 19:37:55.419 Descend Vel PID Values -0.200000 -0.203334 -0.205082 0.001430 -0.010139 0.014977 0.014977 122.000000 3.000000 $ 12-Dec-2018 19:37:55.419 Descend SBE41 Message 22.11 22.110001 19.044484 -0.208886 -0.203334 -0.200000 -0.174266 3.000000 $ 12-Dec-2018 19:37:56.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.110001 157.834068 29.675000 125.000000 $ 12-Dec-2018 19:37:56.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.110001 157.824323 29.675000 125.000000 $ 12-Dec-2018 19:37:57.736 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.110001 157.838359 29.675000 125.000000 $ 12-Dec-2018 19:37:58.419 Descend Vel PID Values -0.200000 -0.206666 -0.204438 0.000643 -0.010118 0.173400 0.173400 1420.000000 3.000000 $ 12-Dec-2018 19:37:58.419 Descend SBE41 Message 22.73 22.730000 19.688743 -0.210270 -0.206666 -0.205000 -0.179494 3.000000 $ 12-Dec-2018 19:37:59.075 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.730000 157.848731 29.675000 125.000000 $ 12-Dec-2018 19:37:59.737 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.730000 157.832272 29.675000 125.000000 $ 12-Dec-2018 19:38:00.738 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.730000 157.812178 29.675000 125.000000 $ 12-Dec-2018 19:38:01.418 Descend Vel PID Values -0.200000 -0.210000 -0.204640 -0.000201 -0.010096 0.414657 0.414657 3396.000000 3.000000 $ 12-Dec-2018 19:38:01.418 Descend SBE41 Message 23.36 23.360001 20.317516 -0.213286 -0.210000 -0.208333 -0.184642 3.000000 $ 12-Dec-2018 19:38:02.076 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.360001 157.824427 29.675000 125.000000 $ 12-Dec-2018 19:38:02.738 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.360001 157.837756 29.675000 125.000000 $ 12-Dec-2018 19:38:03.738 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.360001 157.838576 29.675000 125.000000 $ 12-Dec-2018 19:38:04.418 Descend Vel PID Values -0.200000 -0.196667 -0.203946 0.000693 -0.010077 0.120726 0.120726 988.000000 3.000000 $ 12-Dec-2018 19:38:04.418 Descend SBE41 Message 23.95 23.950001 20.922290 -0.216546 -0.196667 -0.203334 -0.189510 3.000000 $ 12-Dec-2018 19:38:05.078 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.950001 157.836273 29.675000 125.000000 $ 12-Dec-2018 19:38:05.739 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.950001 157.824762 29.675000 125.000000 $ 12-Dec-2018 19:38:06.739 Descend PTH Message 801.614014 23.783333 54.840607 24.847278 $ 12-Dec-2018 19:38:06.941 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.950001 157.818660 29.700000 125.000000 $ 12-Dec-2018 19:38:07.525 Descend Vel PID Values -0.200000 -0.213333 -0.204506 -0.000560 -0.010055 0.499668 0.499668 4093.000000 3.000000 $ 12-Dec-2018 19:38:07.525 Descend SBE41 Message 24.59 24.590000 21.517568 -0.217901 -0.213333 -0.205000 -0.193742 3.000000 $ 12-Dec-2018 19:38:08.080 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.590000 157.825164 29.700000 125.000000 $ 12-Dec-2018 19:38:08.739 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.590000 157.821044 29.700000 125.000000 $ 12-Dec-2018 19:38:09.740 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.590000 157.815889 29.700000 125.000000 $ 12-Dec-2018 19:38:10.420 Descend Vel PID Values -0.200000 -0.193333 -0.203691 0.000815 -0.010037 0.067767 0.067767 555.000000 3.000000 $ 12-Dec-2018 19:38:10.420 Descend SBE41 Message 25.17 25.170000 22.120198 -0.216397 -0.193333 -0.203333 -0.197256 3.000000 $ 12-Dec-2018 19:38:11.080 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 157.812610 29.700000 125.000000 $ 12-Dec-2018 19:38:11.740 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 157.795958 29.700000 125.000000 $ 12-Dec-2018 19:38:12.740 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 157.821596 29.700000 125.000000 $ 12-Dec-2018 19:38:13.418 Descend Vel PID Values -0.200000 -0.116667 -0.194432 0.009258 -0.010064 -2.924306 -2.924306 -23955.000000 3.000000 $ 12-Dec-2018 19:38:13.418 Descend SBE41 Message 25.52 25.520000 22.732388 -0.212981 -0.116667 -0.155000 -0.199980 3.000000 $ 12-Dec-2018 19:38:14.080 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.520000 157.799013 29.700000 125.000000 $ 12-Dec-2018 19:38:14.740 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.520000 157.780685 29.700000 125.000000 $ 12-Dec-2018 19:38:15.740 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.520000 157.779522 29.700000 125.000000 $ 12-Dec-2018 19:38:16.420 Descend Vel PID Values -0.200000 0.013334 -0.168221 0.026211 -0.010217 -9.542056 -9.542056 -78168.000000 3.000000 $ 12-Dec-2018 19:38:16.420 Descend SBE41 Message 25.48 25.480000 23.347097 -0.209646 0.013334 -0.051667 -0.201937 3.000000 $ 12-Dec-2018 19:38:17.079 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.760799 29.700000 125.000000 $ 12-Dec-2018 19:38:18.038 Descend Starting valve close $ 12-Dec-2018 19:38:18.042 Descend Descend glide on $ 12-Dec-2018 19:38:18.445 Descend RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.762229 29.700000 125.000000 $ 12-Dec-2018 19:38:18.556 Descend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0185955 $ 12-Dec-2018 19:38:18.863 Descend RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.737672 29.700000 125.000000 $ 12-Dec-2018 19:38:19.447 Descend SBE41 Message 25.48 25.480000 23.952854 -0.208179 0.000000 0.006667 -0.203150 3.000000 $ 12-Dec-2018 19:38:19.794 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.758497 29.700000 125.000000 $ 12-Dec-2018 19:38:20.766 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.770112 29.700000 125.000000 $ 12-Dec-2018 19:38:21.766 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.777496 29.700000 125.000000 $ 12-Dec-2018 19:38:22.564 Descend Bottom detected based on Platform Velocity near zero $ 12-Dec-2018 19:38:22.419 Descend SBE41 Message 25.48 25.480000 24.519126 -0.208964 0.000000 0.000000 -0.203723 3.000000 $ 12-Dec-2018 19:38:23.001 Descend Normal State Exit $ 12-Dec-2018 19:38:23.107 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.774374 29.700000 125.000000 $ 12-Dec-2018 19:38:23.564 Anchor State Entry $ 12-Dec-2018 19:38:23.671 Anchor Starting valve close $ 12-Dec-2018 19:38:23.675 Anchor Powering up MSC $ 12-Dec-2018 19:38:23.777 Anchor Powering up FLBB $ 12-Dec-2018 19:38:25.476 Anchor Sending FLBB stop command $ 12-Dec-2018 19:38:26.982 Anchor Sending FLBB pkt command: $pkt 1 $ 12-Dec-2018 19:38:28.085 Anchor Sending FLBB ave command: $ave 10 $ 12-Dec-2018 19:38:29.188 Anchor Powering up 4330 Optode $ 12-Dec-2018 19:38:30.692 Anchor Sending Optode Wakeup $ 12-Dec-2018 19:38:34.698 Anchor Powering up OCR504 $ 12-Dec-2018 19:38:34.809 Anchor Starting anchor period = 00:04:00 $ 12-Dec-2018 19:38:36.014 Anchor Error executing 2485 Transaction = 0 $ 12-Dec-2018 19:38:36.320 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.480000 157.743633 29.700000 125.000000 $ 12-Dec-2018 19:38:36.432 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:12.8674987 $ 12-Dec-2018 19:38:25.419 Anchor SBE41 Message 25.49 25.490000 24.984542 -0.210034 -0.003333 -0.001667 -0.203762 3.000000 $ 12-Dec-2018 19:38:36.661 Anchor MSC: RX: $ 12-Dec-2018 19:38:36.763 Anchor MSC: RX: $ 12-Dec-2018 19:38:36.768 Anchor MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initializing... $ 12-Dec-2018 19:38:28.419 Anchor SBE41 Message 25.46 25.459999 25.289489 -0.206850 0.010000 0.003333 -0.203286 3.000000 $ 12-Dec-2018 19:38:29.464 Anchor Optode Message % $ 12-Dec-2018 19:38:29.575 Anchor Optode Message StartupInfo,4330,1532,Mode,AADI Smart Sensor Terminal Protocol,RS232 Protocol Version,3,Config Version,11 $ 12-Dec-2018 19:38:37.529 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.459999 157.764249 29.700000 125.000000 $ 12-Dec-2018 19:38:37.641 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2036063 $ 12-Dec-2018 19:38:37.745 Anchor MSC: RX: MBARI Serial Number : 0777 $ 12-Dec-2018 19:38:37.847 Anchor MSC: RX: CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 $ 12-Dec-2018 19:38:37.853 Anchor MSC: RX: CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 $ 12-Dec-2018 19:38:38.053 Anchor MSC: RX: CF Card: Size=256614400 Avail=99.13% $ 12-Dec-2018 19:38:38.156 Anchor Sending CTD PTS $ 12-Dec-2018 19:38:38.160 Anchor Sending Optode Do Sample $ 12-Dec-2018 19:38:38.364 Anchor Sending Optode Wakeup $ 12-Dec-2018 19:38:38.369 Anchor MSC: RX: CF2 Power Up (GMT): Tue Jan 31 02:03:33 2012 $ 12-Dec-2018 19:38:38.571 Anchor MSC: RX: CF2 RTC Time (GMT): Tue Jan 31 02:03:37 2012 $ 12-Dec-2018 19:38:38.674 Anchor MSC: RX: Adjusted Local Time: Mon Jan 30 18:03:37 2012 $ 12-Dec-2018 19:38:38.776 Anchor MSC: RX: TZ Offset (GMT - LOCAL) : +8.00 hrs. $ 12-Dec-2018 19:38:38.878 Anchor Sending FLBB run command $ 12-Dec-2018 19:38:38.897 Anchor Sending radiometer pollSample $ 12-Dec-2018 19:38:39.101 Anchor MSC: RX: RTC delta (CF2 - DS3234) : -1.00 secs. $ 12-Dec-2018 19:38:31.556 Anchor SBE41 Message 25.24 25.240000 25.432946 -0.193588 0.073333 0.041667 -0.202187 3.000000 $ 12-Dec-2018 19:38:39.232 Anchor MSC: RX: System Batt Voltage = 11.764 $ 12-Dec-2018 19:38:39.432 Anchor MSC: RX: System Load Current = 2.64e-02 $ 12-Dec-2018 19:38:31.722 Anchor Optode Message !# $ 12-Dec-2018 19:38:39.660 Anchor MSC: RX: Housing Temperature = +23.19C = +73.75F $ 12-Dec-2018 19:38:39.666 Anchor MSC: RX: Housing Humidity = 56.7% = 14.1C (DP) $ 12-Dec-2018 19:38:39.971 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.240000 157.772638 29.700000 125.000000 $ 12-Dec-2018 19:38:40.084 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4362339 $ 12-Dec-2018 19:38:40.191 Anchor MSC: RX: Power Cycle Count = 147 $ 12-Dec-2018 19:38:40.196 Anchor MSC: RX: System Reset Count = 151 $ 12-Dec-2018 19:38:40.298 Anchor MSC: RX: System Error Count = 65 $ 12-Dec-2018 19:38:40.400 Anchor MSC: RX: Last System Error = -107 $ 12-Dec-2018 19:38:40.502 Anchor MSC: RX: Last Error Time = Tue Jan 31 01:29:19 2012 $ 12-Dec-2018 19:38:40.702 Anchor MSC: RX: ISUS Error Count = 1 $ 12-Dec-2018 19:38:40.804 Anchor MSC: RX: Last ISUS Error = -202 $ 12-Dec-2018 19:38:40.813 Anchor MSC: RX: Last Error Time = Thu Jan 26 03:13:44 2012 $ 12-Dec-2018 19:38:41.013 Anchor MSC: RX: DURA Error Count = 0 $ 12-Dec-2018 19:38:41.116 Anchor MSC: RX: Last DURA Error = 0 $ 12-Dec-2018 19:38:41.218 Anchor MSC: RX: Last Error Time = Thu Jan 1 00:00:00 1970 $ 12-Dec-2018 19:38:41.321 Anchor MSC: RX: Fiberlite Odometer = 100:11:07 = 360667 secs $ 12-Dec-2018 19:38:41.326 Anchor MSC: RX: Fiberlite Cycles = 231 $ 12-Dec-2018 19:38:41.527 Anchor MSC: RX: Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 $ 12-Dec-2018 19:38:41.634 Anchor MSC: RX: Zeiss Coef File Found 4 coefs loaded. $ 12-Dec-2018 19:38:41.737 Anchor MSC: RX: Ecoef File Found 256 coefs loaded. $ 12-Dec-2018 19:38:42.041 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.240000 157.767192 29.700000 125.000000 $ 12-Dec-2018 19:38:42.154 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0629424 $ 12-Dec-2018 19:38:42.257 Anchor MSC: RX: There are 71 records in the error file! $ 12-Dec-2018 19:38:42.360 Anchor MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initialized $ 12-Dec-2018 19:38:42.365 Anchor MSC: RX: Auto Shutdown in 10 hours at: Tue Jan 31 12:03:38 2012 $ 12-Dec-2018 19:38:42.471 Anchor MSC: RX: Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode $ 12-Dec-2018 19:38:32.843 Anchor Optode Message # $ 12-Dec-2018 19:38:33.740 Anchor Optode Message # $ 12-Dec-2018 19:38:34.420 Anchor SBE41 Message 25.06 25.059999 25.474771 -0.166424 0.060000 0.066667 -0.200479 3.000000 $ 12-Dec-2018 19:38:42.927 Anchor Radiometer Message Satlantic OCR-504 Multispectral Radiometer $ 12-Dec-2018 19:38:43.152 Anchor Radiometer Message Copyright (C) 2011, Satlantic Inc. All rights reserved. $ 12-Dec-2018 19:38:43.163 Anchor Radiometer Message Firmware version: 5.1.0 - SatNet Type B $ 12-Dec-2018 19:38:43.369 Anchor Radiometer Message Ins tMruulmteinsstp:e cStArTTaFlI 4R $ 12-Dec-2018 19:38:43.380 Anchor Radiometer Message a $ 12-Dec-2018 19:38:43.488 Anchor Radiometer Message ddSi/oNm:e tt0e2r8 $ 12-Dec-2018 19:38:43.695 Anchor Radiometer Message 7 $ 12-Dec-2018 19:38:44.005 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 157.755293 29.700000 125.000000 $ 12-Dec-2018 19:38:44.116 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9572127 $ 12-Dec-2018 19:38:44.123 Anchor Radiometer Message CC $ 12-Dec-2018 19:38:44.231 Anchor Radiometer Message o $ 12-Dec-2018 19:38:44.339 Anchor Radiometer Message p $ 12-Dec-2018 19:38:44.447 Anchor Radiometer Message yRreiisgehtt S((oCu)r c2e0:11 1P,o wer $ 12-Dec-2018 19:38:44.559 Anchor Radiometer Message Press for command console. $ 12-Dec-2018 19:38:44.767 Anchor Radiometer Message Initializing system. Please wait... $ 12-Dec-2018 19:38:37.442 Anchor SBE41 Message 25.07 25.070000 25.473857 -0.127042 -0.003333 0.028333 -0.198106 3.000000 $ 12-Dec-2018 19:38:44.903 Anchor Radiometer Message Autonomous operation enabled. $ 12-Dec-2018 19:38:39.898 Anchor Unparsed SBE41 Message S> $ 12-Dec-2018 19:38:45.130 Anchor Radiometer Message SATFI40287,-0.0053,-0.0024,-0.0065,-0.1871 $ 12-Dec-2018 19:38:39.969 Anchor Optode Message 4330,1532,264.176,22.569,29.148,29.079,36.122,7.043,537.4,466.5,108.1 $ 12-Dec-2018 19:38:40.081 Anchor Optode Message # $ 12-Dec-2018 19:38:45.469 Anchor FLBB Message /99/99,99:99:99,695,2306,700,4130,538 $ 12-Dec-2018 19:38:45.881 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.070000 157.760106 29.700000 125.000000 $ 12-Dec-2018 19:38:45.992 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8687963 $ 12-Dec-2018 19:38:42.001 Anchor SBE41 Message 25.06 25.059999 25.443011 -0.082878 0.003333 0.000000 -0.194617 3.000000 $ 12-Dec-2018 19:38:45.109 Anchor SBE41 Message 25.07 25.070000 25.368566 -0.043119 -0.003333 0.000000 -0.190441 3.000000 $ 12-Dec-2018 19:38:46.451 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.070000 157.764100 29.700000 125.000000 $ 12-Dec-2018 19:38:47.200 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.070000 157.747760 29.700000 125.000000 $ 12-Dec-2018 19:38:47.920 Anchor SBE41 Message 25.69 25.690001 25.258803 -0.013394 -0.206667 -0.105000 -0.185685 3.000000 $ 12-Dec-2018 19:38:48.228 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.690001 157.787792 29.700000 125.000000 $ 12-Dec-2018 19:38:49.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.690001 157.764547 29.700000 125.000000 $ 12-Dec-2018 19:38:50.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.690001 157.760799 29.700000 125.000000 $ 12-Dec-2018 19:38:50.919 Anchor SBE41 Message 25.66 25.660000 25.156581 0.006437 0.010000 -0.098333 -0.180367 3.000000 $ 12-Dec-2018 19:38:51.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 157.771856 29.700000 125.000000 $ 12-Dec-2018 19:38:52.203 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 157.760821 29.700000 125.000000 $ 12-Dec-2018 19:38:53.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 157.760143 29.700000 125.000000 $ 12-Dec-2018 19:38:53.920 Anchor SBE41 Message 25.66 25.660000 25.109243 0.019587 0.000000 0.005000 -0.174616 3.000000 $ 12-Dec-2018 19:38:54.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 157.777213 29.700000 125.000000 $ 12-Dec-2018 19:38:55.203 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 157.775648 29.700000 125.000000 $ 12-Dec-2018 19:38:56.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 157.777943 29.700000 125.000000 $ 12-Dec-2018 19:38:56.919 Anchor SBE41 Message 25.25 25.250000 25.149709 0.027664 0.136667 0.068333 -0.168577 3.000000 $ 12-Dec-2018 19:38:57.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.250000 157.757871 29.700000 125.000000 $ 12-Dec-2018 19:38:58.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.250000 157.761224 29.700000 125.000000 $ 12-Dec-2018 19:38:59.201 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.250000 157.762535 29.700000 125.000000 $ 12-Dec-2018 19:38:59.920 Anchor SBE41 Message 24.86 24.860001 25.282766 0.028378 0.130000 0.133333 -0.162374 3.000000 $ 12-Dec-2018 19:39:00.230 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.860001 157.749116 29.700000 125.000000 $ 12-Dec-2018 19:39:01.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.860001 157.762147 29.700000 125.000000 $ 12-Dec-2018 19:39:02.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.860001 157.788448 29.700000 125.000000 $ 12-Dec-2018 19:39:02.919 Anchor SBE41 Message 24.88 24.879999 25.447160 0.017938 -0.006666 0.061667 -0.156055 3.000000 $ 12-Dec-2018 19:39:03.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.879999 157.758586 29.700000 125.000000 $ 12-Dec-2018 19:39:04.203 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.879999 157.765962 29.700000 125.000000 $ 12-Dec-2018 19:39:05.201 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.879999 157.772325 29.700000 125.000000 $ 12-Dec-2018 19:39:05.918 Anchor SBE41 Message 25.73 25.730000 25.528134 -0.002870 -0.283333 -0.145000 -0.149547 3.000000 $ 12-Dec-2018 19:39:06.328 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.762863 29.700000 125.000000 $ 12-Dec-2018 19:39:07.202 Anchor PTH Message 800.101318 23.958333 54.703278 24.890178 $ 12-Dec-2018 19:39:07.405 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.761633 29.725000 142.000000 $ 12-Dec-2018 19:39:08.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.770172 29.725000 142.000000 $ 12-Dec-2018 19:39:08.919 Anchor SBE41 Message 25.76 25.760000 25.454692 -0.024870 -0.010000 -0.146667 -0.142693 3.000000 $ 12-Dec-2018 19:39:09.230 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.774106 29.725000 142.000000 $ 12-Dec-2018 19:39:10.203 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.765478 29.725000 142.000000 $ 12-Dec-2018 19:39:11.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.745764 29.725000 142.000000 $ 12-Dec-2018 19:39:11.920 Anchor SBE41 Message 25.73 25.730000 25.281399 -0.034605 0.010000 0.000000 -0.135463 3.000000 $ 12-Dec-2018 19:39:12.230 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.772377 29.725000 142.000000 $ 12-Dec-2018 19:39:13.204 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.778136 29.725000 142.000000 $ 12-Dec-2018 19:39:14.204 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.770850 29.725000 142.000000 $ 12-Dec-2018 19:39:14.920 Anchor SBE41 Message 24.78 24.780001 25.167614 -0.024170 0.316666 0.163333 -0.127980 3.000000 $ 12-Dec-2018 19:39:15.231 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.766543 29.725000 142.000000 $ 12-Dec-2018 19:39:16.205 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.768786 29.725000 142.000000 $ 12-Dec-2018 19:39:17.204 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.760181 29.725000 142.000000 $ 12-Dec-2018 19:39:17.920 Anchor SBE41 Message 24.79 24.790001 25.235798 0.000638 -0.003333 0.156666 -0.120500 3.000000 $ 12-Dec-2018 19:39:18.232 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.762125 29.725000 142.000000 $ 12-Dec-2018 19:39:19.205 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.756075 29.725000 142.000000 $ 12-Dec-2018 19:39:20.205 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.761477 29.725000 142.000000 $ 12-Dec-2018 19:39:20.920 Anchor SBE41 Message 25.62 25.620001 25.419376 0.021545 -0.276667 -0.140000 -0.113166 3.000000 $ 12-Dec-2018 19:39:21.232 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.620001 157.758079 29.725000 142.000000 $ 12-Dec-2018 19:39:22.206 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.620001 157.766066 29.725000 142.000000 $ 12-Dec-2018 19:39:23.205 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.620001 157.761231 29.725000 142.000000 $ 12-Dec-2018 19:39:23.920 Anchor SBE41 Message 25.81 25.809999 25.510215 0.021753 -0.063333 -0.170000 -0.105881 3.000000 $ 12-Dec-2018 19:39:24.233 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.809999 157.773040 29.725000 142.000000 $ 12-Dec-2018 19:39:25.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.809999 157.751761 29.725000 142.000000 $ 12-Dec-2018 19:39:26.206 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.809999 157.784738 29.725000 142.000000 $ 12-Dec-2018 19:39:26.919 Anchor SBE41 Message 25.81 25.809999 25.401382 0.002621 0.000000 -0.031666 -0.098441 3.000000 $ 12-Dec-2018 19:39:27.234 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.809999 157.775171 29.725000 142.000000 $ 12-Dec-2018 19:39:28.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.809999 157.766245 29.725000 142.000000 $ 12-Dec-2018 19:39:29.206 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.809999 157.750830 29.725000 142.000000 $ 12-Dec-2018 19:39:29.919 Anchor SBE41 Message 24.78 24.780001 25.232735 -0.016068 0.343333 0.171666 -0.090819 3.000000 $ 12-Dec-2018 19:39:30.234 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.749020 29.725000 142.000000 $ 12-Dec-2018 19:39:31.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.768905 29.725000 142.000000 $ 12-Dec-2018 19:39:32.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.757312 29.725000 142.000000 $ 12-Dec-2018 19:39:32.920 Anchor SBE41 Message 24.78 24.780001 25.225213 -0.016224 0.000000 0.171666 -0.083250 3.000000 $ 12-Dec-2018 19:39:33.234 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.763146 29.725000 142.000000 $ 12-Dec-2018 19:39:34.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.761961 29.725000 142.000000 $ 12-Dec-2018 19:39:35.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.757938 29.725000 142.000000 $ 12-Dec-2018 19:39:35.920 Anchor SBE41 Message 25.74 25.740000 25.389989 -0.000473 -0.320000 -0.160000 -0.075974 3.000000 $ 12-Dec-2018 19:39:36.333 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.754757 29.725000 142.000000 $ 12-Dec-2018 19:39:37.024 Anchor ERROR: Missed PH message 1 $ 12-Dec-2018 19:39:37.126 Anchor ERROR: Missed NO3 message 1 $ 12-Dec-2018 19:39:37.234 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.762505 29.725000 142.000000 $ 12-Dec-2018 19:39:37.345 Anchor Unparsed SBE41 Message S> $ 12-Dec-2018 19:39:38.227 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.765590 29.725000 142.000000 $ 12-Dec-2018 19:39:38.337 Anchor Sending CTD PTS $ 12-Dec-2018 19:39:38.343 Anchor Sending Optode Do Sample $ 12-Dec-2018 19:39:38.449 Anchor Sending Optode Wakeup $ 12-Dec-2018 19:39:38.445 Anchor Unparsed SBE41 Message S>pts $ 12-Dec-2018 19:39:39.149 Anchor Sending FLBB run command $ 12-Dec-2018 19:39:39.165 Anchor Sending radiometer pollSample $ 12-Dec-2018 19:39:39.373 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.756649 29.725000 142.000000 $ 12-Dec-2018 19:39:40.006 Anchor Radiometer Message SATFI40287,-0.0046,-0.0023,-0.0065,-0.1885 $ 12-Dec-2018 19:39:40.322 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.767490 29.725000 142.000000 $ 12-Dec-2018 19:39:40.239 Anchor Optode Message 4330,1532,264.037,22.585,29.147,29.078,36.124,7.046,537.3,466.2,107.6 $ 12-Dec-2018 19:39:40.243 Anchor Optode Message # $ 12-Dec-2018 19:39:41.135 Anchor FLBB Message /99/99,99:99:99,695,2305,700,4130,536 $ 12-Dec-2018 19:39:41.545 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.758370 29.725000 142.000000 $ 12-Dec-2018 19:39:42.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.757327 29.725000 142.000000 $ 12-Dec-2018 19:39:43.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.756679 29.725000 142.000000 $ 12-Dec-2018 19:39:44.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.755464 29.725000 142.000000 $ 12-Dec-2018 19:39:45.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.759093 29.725000 142.000000 $ 12-Dec-2018 19:39:45.549 Anchor SBE41 Message 24.81, 22.0824, 34.1863 24.809999 25.507922 0.011902 0.310000 -0.005000 -0.068106 3.000000 $ 12-Dec-2018 19:39:46.242 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.761008 29.725000 142.000000 $ 12-Dec-2018 19:39:47.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.755516 29.725000 142.000000 $ 12-Dec-2018 19:39:48.209 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.781243 29.725000 142.000000 $ 12-Dec-2018 19:39:48.452 Anchor Unparsed SBE41 Message S> $ 12-Dec-2018 19:39:49.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.763869 29.725000 142.000000 $ 12-Dec-2018 19:39:50.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.759197 29.725000 142.000000 $ 12-Dec-2018 19:39:50.920 Anchor SBE41 Message 25.47 25.469999 25.422184 0.007470 -0.220000 0.045000 -0.060223 3.000000 $ 12-Dec-2018 19:39:51.246 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.469999 157.783031 29.725000 142.000000 $ 12-Dec-2018 19:39:52.209 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.469999 157.770306 29.725000 142.000000 $ 12-Dec-2018 19:39:53.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.469999 157.757640 29.725000 142.000000 $ 12-Dec-2018 19:39:53.919 Anchor SBE41 Message 25.77 25.770000 25.238355 -0.006450 -0.100000 -0.160000 -0.052588 3.000000 $ 12-Dec-2018 19:39:54.235 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 157.770008 29.725000 142.000000 $ 12-Dec-2018 19:39:55.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 157.770351 29.725000 142.000000 $ 12-Dec-2018 19:39:56.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 157.739371 29.725000 142.000000 $ 12-Dec-2018 19:39:56.918 Anchor SBE41 Message 25.76 25.760000 25.150370 -0.011735 0.003333 -0.048333 -0.045333 3.000000 $ 12-Dec-2018 19:39:57.333 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.761715 29.725000 142.000000 $ 12-Dec-2018 19:39:58.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.755636 29.725000 142.000000 $ 12-Dec-2018 19:39:59.207 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.737888 29.725000 142.000000 $ 12-Dec-2018 19:39:59.919 Anchor SBE41 Message 24.80 24.799999 25.189885 -0.000473 0.320000 0.161667 -0.038623 3.000000 $ 12-Dec-2018 19:40:00.235 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.769255 29.725000 142.000000 $ 12-Dec-2018 19:40:01.209 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.740347 29.725000 142.000000 $ 12-Dec-2018 19:40:02.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.771565 29.725000 142.000000 $ 12-Dec-2018 19:40:02.919 Anchor SBE41 Message 24.79 24.790001 25.288468 0.017647 0.003333 0.161667 -0.032531 3.000000 $ 12-Dec-2018 19:40:03.236 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.764077 29.725000 142.000000 $ 12-Dec-2018 19:40:04.209 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.769270 29.725000 142.000000 $ 12-Dec-2018 19:40:05.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.760672 29.725000 142.000000 $ 12-Dec-2018 19:40:05.920 Anchor SBE41 Message 24.84 24.840000 25.410273 0.024787 -0.016666 -0.006667 -0.027090 3.000000 $ 12-Dec-2018 19:40:06.236 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.840000 157.750085 29.725000 142.000000 $ 12-Dec-2018 19:40:07.210 Anchor PTH Message 800.652588 24.016667 54.619354 24.922354 $ 12-Dec-2018 19:40:07.412 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.840000 157.787323 38.375000 142.500000 $ 12-Dec-2018 19:40:08.208 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.840000 157.776818 38.375000 142.500000 $ 12-Dec-2018 19:40:08.919 Anchor SBE41 Message 25.76 25.760000 25.474529 0.011068 -0.306667 -0.161667 -0.022228 3.000000 $ 12-Dec-2018 19:40:09.237 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.773957 38.375000 142.500000 $ 12-Dec-2018 19:40:10.211 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.779500 38.375000 142.500000 $ 12-Dec-2018 19:40:11.211 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.761805 38.375000 142.500000 $ 12-Dec-2018 19:40:11.920 Anchor SBE41 Message 25.74 25.740000 25.371695 -0.013504 0.006667 -0.150000 -0.017734 3.000000 $ 12-Dec-2018 19:40:12.238 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.775596 38.375000 142.500000 $ 12-Dec-2018 19:40:13.212 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.782584 38.375000 142.500000 $ 12-Dec-2018 19:40:14.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.740000 157.756984 38.375000 142.500000 $ 12-Dec-2018 19:40:14.918 Anchor SBE41 Message 25.05 25.049999 25.158982 -0.025931 0.230000 0.118333 -0.013479 3.000000 $ 12-Dec-2018 19:40:15.337 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.049999 157.758951 38.375000 142.500000 $ 12-Dec-2018 19:40:16.211 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.049999 157.770663 38.375000 142.500000 $ 12-Dec-2018 19:40:17.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.049999 157.766156 38.375000 142.500000 $ 12-Dec-2018 19:40:17.919 Anchor SBE41 Message 24.79 24.790001 25.050010 -0.013923 0.086666 0.158333 -0.009604 3.000000 $ 12-Dec-2018 19:40:18.238 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.752424 38.375000 142.500000 $ 12-Dec-2018 19:40:19.211 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.759003 38.375000 142.500000 $ 12-Dec-2018 19:40:20.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.759108 38.375000 142.500000 $ 12-Dec-2018 19:40:20.918 Anchor SBE41 Message 24.79 24.790001 25.153425 0.011403 0.000000 0.043333 -0.006366 3.000000 $ 12-Dec-2018 19:40:21.336 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.768704 38.375000 142.500000 $ 12-Dec-2018 19:40:22.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.783732 38.375000 142.500000 $ 12-Dec-2018 19:40:23.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.771483 38.375000 142.500000 $ 12-Dec-2018 19:40:23.918 Anchor SBE41 Message 25.79 25.790001 25.327622 0.028226 -0.333333 -0.166667 -0.003864 3.000000 $ 12-Dec-2018 19:40:24.237 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.774180 38.375000 142.500000 $ 12-Dec-2018 19:40:25.211 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.774284 38.375000 142.500000 $ 12-Dec-2018 19:40:26.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.778986 38.375000 142.500000 $ 12-Dec-2018 19:40:26.919 Anchor SBE41 Message 25.76 25.760000 25.352164 0.023951 0.010000 -0.161667 -0.001946 3.000000 $ 12-Dec-2018 19:40:27.336 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.746501 38.375000 142.500000 $ 12-Dec-2018 19:40:28.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.771111 38.375000 142.500000 $ 12-Dec-2018 19:40:29.209 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.758139 38.375000 142.500000 $ 12-Dec-2018 19:40:29.920 Anchor SBE41 Message 25.36 25.360001 25.206804 0.004284 0.133333 0.071667 -0.000441 3.000000 $ 12-Dec-2018 19:40:30.237 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.360001 157.767259 38.375000 142.500000 $ 12-Dec-2018 19:40:31.211 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.360001 157.755524 38.375000 142.500000 $ 12-Dec-2018 19:40:32.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.360001 157.780610 38.375000 142.500000 $ 12-Dec-2018 19:40:32.920 Anchor SBE41 Message 24.79 24.790001 25.095788 -0.011893 0.190000 0.161667 0.000619 3.000000 $ 12-Dec-2018 19:40:33.339 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.759383 38.375000 142.500000 $ 12-Dec-2018 19:40:34.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.770097 38.375000 142.500000 $ 12-Dec-2018 19:40:35.210 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.762788 38.375000 142.500000 $ 12-Dec-2018 19:40:35.920 Anchor SBE41 Message 24.79 24.790001 25.180138 -0.010463 0.000000 0.095000 0.001104 3.000000 $ 12-Dec-2018 19:40:36.238 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.769747 38.375000 142.500000 $ 12-Dec-2018 19:40:37.025 Anchor ERROR: Missed PH message 2 $ 12-Dec-2018 19:40:37.127 Anchor ERROR: Missed NO3 message 2 $ 12-Dec-2018 19:40:37.235 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.769501 38.375000 142.500000 $ 12-Dec-2018 19:40:37.345 Anchor Unparsed SBE41 Message S> $ 12-Dec-2018 19:40:38.230 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.778010 38.375000 142.500000 $ 12-Dec-2018 19:40:38.342 Anchor Sending CTD PTS $ 12-Dec-2018 19:40:38.346 Anchor Sending Optode Do Sample $ 12-Dec-2018 19:40:38.550 Anchor Sending Optode Wakeup $ 12-Dec-2018 19:40:38.449 Anchor Unparsed SBE41 Message S>pts $ 12-Dec-2018 19:40:39.126 Anchor Sending FLBB run command $ 12-Dec-2018 19:40:39.143 Anchor Sending radiometer pollSample $ 12-Dec-2018 19:40:39.491 Anchor Error in I2CPortBase.Execute $ 12-Dec-2018 19:40:39.593 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.778010 38.375000 142.500000 $ 12-Dec-2018 19:40:41.210 Anchor Error executing 2485 Transaction = 0 $ 12-Dec-2018 19:40:41.312 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 250.000000 38.375000 142.500000 $ 12-Dec-2018 19:40:41.426 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4169540 $ 12-Dec-2018 19:40:40.217 Anchor Optode Message 4330,1532,264.090,22.605,29.137,29.067,36.116,7.049,537.1,465.8,106.9 $ 12-Dec-2018 19:40:40.220 Anchor Optode Message # $ 12-Dec-2018 19:40:41.656 Anchor FLBB Message /99/99,99:99:99,695,2304,700,4130,535 $ 12-Dec-2018 19:40:42.068 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.775946 38.375000 142.500000 $ 12-Dec-2018 19:40:42.633 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.753721 38.375000 142.500000 $ 12-Dec-2018 19:40:43.633 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.779723 38.375000 142.500000 $ 12-Dec-2018 19:40:44.633 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.772757 38.375000 142.500000 $ 12-Dec-2018 19:40:45.632 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.762706 38.375000 142.500000 $ 12-Dec-2018 19:40:45.553 Anchor SBE41 Message 25.37, 22.1307, 34.1805 25.370001 25.367204 0.002364 -0.193333 -0.096667 0.001039 3.000000 $ 12-Dec-2018 19:40:46.767 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.370001 157.767735 38.375000 142.500000 $ 12-Dec-2018 19:40:47.633 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.370001 157.756574 38.375000 142.500000 $ 12-Dec-2018 19:40:48.632 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.370001 157.759167 38.375000 142.500000 $ 12-Dec-2018 19:40:48.920 Anchor SBE41 Message 24.79 24.790001 25.429352 0.007717 0.193333 0.000000 0.000755 3.000000 $ 12-Dec-2018 19:40:49.760 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.769389 38.375000 142.500000 $ 12-Dec-2018 19:40:50.634 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.756694 38.375000 142.500000 $ 12-Dec-2018 19:40:51.633 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.761157 38.375000 142.500000 $ 12-Dec-2018 19:40:51.920 Anchor SBE41 Message 24.78 24.780001 25.291419 -0.002353 0.003333 0.098333 0.000587 3.000000 $ 12-Dec-2018 19:40:52.761 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.764748 38.375000 142.500000 $ 12-Dec-2018 19:40:53.635 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.768518 38.375000 142.500000 $ 12-Dec-2018 19:40:54.633 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.754906 38.375000 142.500000 $ 12-Dec-2018 19:40:54.920 Anchor SBE41 Message 25.76 25.760000 25.101093 -0.015214 -0.326667 -0.161667 0.000622 3.000000 $ 12-Dec-2018 19:40:55.761 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.775939 38.375000 142.500000 $ 12-Dec-2018 19:40:56.635 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.759458 38.375000 142.500000 $ 12-Dec-2018 19:40:57.634 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.757506 38.375000 142.500000 $ 12-Dec-2018 19:40:57.920 Anchor SBE41 Message 25.78 25.780001 25.006507 -0.013266 -0.006667 -0.166667 0.000772 3.000000 $ 12-Dec-2018 19:40:58.763 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.780001 157.763034 38.375000 142.500000 $ 12-Dec-2018 19:40:59.635 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.780001 157.763794 38.375000 142.500000 $ 12-Dec-2018 19:41:00.635 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.780001 157.772616 38.375000 142.500000 $ 12-Dec-2018 19:41:00.920 Anchor SBE41 Message 25.43 25.430000 24.999215 0.005946 0.116667 0.055000 0.000982 3.000000 $ 12-Dec-2018 19:41:01.664 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.430000 157.780029 38.375000 142.500000 $ 12-Dec-2018 19:41:02.636 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.430000 157.761164 38.375000 142.500000 $ 12-Dec-2018 19:41:03.636 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.430000 157.755196 38.375000 142.500000 $ 12-Dec-2018 19:41:03.919 Anchor SBE41 Message 24.78 24.780001 25.044207 0.028169 0.216667 0.166667 0.001236 3.000000 $ 12-Dec-2018 19:41:04.667 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.770038 38.375000 142.500000 $ 12-Dec-2018 19:41:05.637 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.764666 38.375000 142.500000 $ 12-Dec-2018 19:41:06.635 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.765865 38.375000 142.500000 $ 12-Dec-2018 19:41:06.918 Anchor SBE41 Message 24.79 24.790001 25.181961 0.035997 -0.003333 0.106667 0.001441 3.000000 $ 12-Dec-2018 19:41:07.763 Anchor PTH Message 800.873535 24.141667 54.558319 24.954529 $ 12-Dec-2018 19:41:07.967 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.768920 29.725000 142.500000 $ 12-Dec-2018 19:41:08.637 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.759354 29.725000 142.500000 $ 12-Dec-2018 19:41:09.635 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.772481 29.725000 142.500000 $ 12-Dec-2018 19:41:09.920 Anchor SBE41 Message 25.79 25.790001 25.373294 0.021688 -0.333333 -0.168333 0.001501 3.000000 $ 12-Dec-2018 19:41:10.763 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.768354 29.725000 142.500000 $ 12-Dec-2018 19:41:11.637 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.776244 29.725000 142.500000 $ 12-Dec-2018 19:41:12.636 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.772198 29.725000 142.500000 $ 12-Dec-2018 19:41:12.920 Anchor SBE41 Message 25.75 25.750000 25.443746 -0.007048 0.013334 -0.160000 0.001464 3.000000 $ 12-Dec-2018 19:41:13.764 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.764979 29.725000 142.500000 $ 12-Dec-2018 19:41:14.637 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.767445 29.725000 142.500000 $ 12-Dec-2018 19:41:15.636 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.775730 29.725000 142.500000 $ 12-Dec-2018 19:41:15.920 Anchor SBE41 Message 25.71 25.709999 25.322912 -0.031506 0.013334 0.013334 0.001427 3.000000 $ 12-Dec-2018 19:41:16.764 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.709999 157.763891 29.725000 142.500000 $ 12-Dec-2018 19:41:17.638 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.709999 157.760575 29.725000 142.500000 $ 12-Dec-2018 19:41:18.637 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.709999 157.763459 29.725000 142.500000 $ 12-Dec-2018 19:41:18.920 Anchor SBE41 Message 24.79 24.790001 25.183202 -0.036373 0.306666 0.160000 0.001360 3.000000 $ 12-Dec-2018 19:41:19.765 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.756381 29.725000 142.500000 $ 12-Dec-2018 19:41:20.638 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.771304 29.725000 142.500000 $ 12-Dec-2018 19:41:21.637 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.763086 29.725000 142.500000 $ 12-Dec-2018 19:41:21.920 Anchor SBE41 Message 24.80 24.799999 25.225028 -0.021636 -0.003333 0.151667 0.001149 3.000000 $ 12-Dec-2018 19:41:22.764 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.760605 29.725000 142.500000 $ 12-Dec-2018 19:41:23.638 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.765828 29.725000 142.500000 $ 12-Dec-2018 19:41:24.638 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.769956 29.725000 142.500000 $ 12-Dec-2018 19:41:24.919 Anchor SBE41 Message 25.76 25.760000 25.408900 -0.001223 -0.320000 -0.161667 0.000816 3.000000 $ 12-Dec-2018 19:41:25.765 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.791011 29.725000 142.500000 $ 12-Dec-2018 19:41:26.639 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.757036 29.725000 142.500000 $ 12-Dec-2018 19:41:27.639 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.763042 29.725000 142.500000 $ 12-Dec-2018 19:41:27.919 Anchor SBE41 Message 25.77 25.770000 25.507166 0.008310 -0.003333 -0.161667 0.000571 3.000000 $ 12-Dec-2018 19:41:28.670 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 157.761678 29.725000 142.500000 $ 12-Dec-2018 19:41:29.640 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 157.762982 29.725000 142.500000 $ 12-Dec-2018 19:41:30.640 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 157.779671 29.725000 142.500000 $ 12-Dec-2018 19:41:30.919 Anchor SBE41 Message 25.76 25.760000 25.403647 0.000960 0.003333 0.000000 0.000569 3.000000 $ 12-Dec-2018 19:41:31.767 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.754838 29.725000 142.500000 $ 12-Dec-2018 19:41:32.640 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.757938 29.725000 142.500000 $ 12-Dec-2018 19:41:33.639 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.760000 157.763802 29.725000 142.500000 $ 12-Dec-2018 19:41:33.919 Anchor SBE41 Message 24.80 24.799999 25.246849 -0.012309 0.320000 0.161667 0.000663 3.000000 $ 12-Dec-2018 19:41:34.771 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.784976 29.725000 142.500000 $ 12-Dec-2018 19:41:35.641 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.766052 29.725000 142.500000 $ 12-Dec-2018 19:41:36.639 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.766476 29.725000 142.500000 $ 12-Dec-2018 19:41:37.025 Anchor ERROR: Missed PH message 3 $ 12-Dec-2018 19:41:37.030 Anchor ERROR: Missed NO3 message 3 $ 12-Dec-2018 19:41:37.132 Anchor ERROR: Missed OCR message 1 $ 12-Dec-2018 19:41:36.920 Anchor SBE41 Message 24.81 24.809999 25.254624 -0.014345 -0.003333 0.158333 0.000540 3.000000 $ 12-Dec-2018 19:41:37.767 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.769546 29.725000 142.500000 $ 12-Dec-2018 19:41:38.333 Anchor Sending CTD PTS $ 12-Dec-2018 19:41:38.337 Anchor Sending Optode Do Sample $ 12-Dec-2018 19:41:38.444 Anchor Sending Optode Wakeup $ 12-Dec-2018 19:41:38.439 Anchor Unparsed SBE41 Message S>pts $ 12-Dec-2018 19:41:38.868 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.764904 29.725000 142.500000 $ 12-Dec-2018 19:41:39.046 Anchor Sending FLBB run command $ 12-Dec-2018 19:41:39.063 Anchor Sending radiometer pollSample $ 12-Dec-2018 19:41:39.546 Anchor Radiometer Message SATFI40287,-0.0053,-0.0010,-0.0066,-0.2090 $ 12-Dec-2018 19:41:39.863 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.770552 29.725000 142.500000 $ 12-Dec-2018 19:41:40.137 Anchor Optode Message 4330,1532,263.900,22.635,29.133,29.063,36.113,7.050,536.9,465.5,106.0 $ 12-Dec-2018 19:41:40.140 Anchor Optode Message # $ 12-Dec-2018 19:41:40.675 Anchor FLBB Message /99/99,99:99:99,695,2305,700,4130,535 $ 12-Dec-2018 19:41:41.087 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.759123 29.725000 142.500000 $ 12-Dec-2018 19:41:41.748 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.767579 29.725000 142.500000 $ 12-Dec-2018 19:41:42.749 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.768197 29.725000 142.500000 $ 12-Dec-2018 19:41:43.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.779098 29.725000 142.500000 $ 12-Dec-2018 19:41:44.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.791056 29.725000 142.500000 $ 12-Dec-2018 19:41:45.545 Anchor SBE41 Message 25.75, 22.1583, 34.1834 25.750000 25.419982 -0.002401 -0.313334 -0.158333 0.000113 3.000000 $ 12-Dec-2018 19:41:45.782 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.770924 29.725000 142.500000 $ 12-Dec-2018 19:41:46.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.767422 29.725000 142.500000 $ 12-Dec-2018 19:41:47.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.801673 29.725000 142.500000 $ 12-Dec-2018 19:41:47.952 Anchor Unparsed SBE41 Message S> $ 12-Dec-2018 19:41:48.867 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.785907 29.725000 142.500000 $ 12-Dec-2018 19:41:49.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.772385 29.725000 142.500000 $ 12-Dec-2018 19:41:50.419 Anchor SBE41 Message 24.81 24.809999 25.520602 0.008328 0.313334 0.000000 -0.000311 3.000000 $ 12-Dec-2018 19:41:50.778 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.750115 29.725000 142.500000 $ 12-Dec-2018 19:41:51.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.761879 29.725000 142.500000 $ 12-Dec-2018 19:41:52.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.789916 29.725000 142.500000 $ 12-Dec-2018 19:41:53.419 Anchor SBE41 Message 24.81 24.809999 25.420943 0.004754 0.000000 0.156667 -0.000415 3.000000 $ 12-Dec-2018 19:41:53.876 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.770813 29.725000 142.500000 $ 12-Dec-2018 19:41:54.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.767043 29.725000 142.500000 $ 12-Dec-2018 19:41:55.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.762073 29.725000 142.500000 $ 12-Dec-2018 19:41:56.419 Anchor SBE41 Message 25.73 25.730000 25.238588 -0.007177 -0.306667 -0.153333 -0.000296 3.000000 $ 12-Dec-2018 19:41:56.778 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.763749 29.725000 142.500000 $ 12-Dec-2018 19:41:57.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.781146 29.725000 142.500000 $ 12-Dec-2018 19:41:58.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.730000 157.776162 29.725000 142.500000 $ 12-Dec-2018 19:41:59.420 Anchor SBE41 Message 25.75 25.750000 25.144190 -0.010707 -0.006667 -0.156667 -0.000274 3.000000 $ 12-Dec-2018 19:41:59.876 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.772295 29.725000 142.500000 $ 12-Dec-2018 19:42:00.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.757521 29.725000 142.500000 $ 12-Dec-2018 19:42:01.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.766104 29.725000 142.500000 $ 12-Dec-2018 19:42:02.420 Anchor SBE41 Message 25.75 25.750000 25.131965 0.001488 0.000000 -0.003333 -0.000370 3.000000 $ 12-Dec-2018 19:42:02.777 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.775201 29.725000 142.500000 $ 12-Dec-2018 19:42:03.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.754704 29.725000 142.500000 $ 12-Dec-2018 19:42:04.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.767482 29.725000 142.500000 $ 12-Dec-2018 19:42:05.419 Anchor SBE41 Message 24.82 24.820000 25.142709 0.020917 0.310000 0.155000 -0.000397 3.000000 $ 12-Dec-2018 19:42:05.876 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.820000 157.753147 29.725000 142.500000 $ 12-Dec-2018 19:42:06.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.820000 157.749973 29.725000 142.500000 $ 12-Dec-2018 19:42:07.749 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.820000 157.764189 29.725000 142.500000 $ 12-Dec-2018 19:42:08.419 Anchor SBE41 Message 24.81 24.809999 25.232463 0.032139 0.003333 0.156667 -0.000339 3.000000 $ 12-Dec-2018 19:42:08.777 Anchor PTH Message 802.000977 24.025000 54.504913 24.965254 $ 12-Dec-2018 19:42:08.981 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.760359 29.725000 140.500000 $ 12-Dec-2018 19:42:09.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.766059 29.725000 140.500000 $ 12-Dec-2018 19:42:10.749 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.760873 29.725000 140.500000 $ 12-Dec-2018 19:42:11.418 Anchor SBE41 Message 24.81 24.809999 25.409431 0.024393 0.000000 0.001667 -0.000375 3.000000 $ 12-Dec-2018 19:42:11.778 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.771416 29.725000 140.500000 $ 12-Dec-2018 19:42:12.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.760486 29.725000 140.500000 $ 12-Dec-2018 19:42:13.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.751188 29.725000 140.500000 $ 12-Dec-2018 19:42:14.418 Anchor SBE41 Message 25.75 25.750000 25.507370 0.000570 -0.313334 -0.156667 -0.000542 3.000000 $ 12-Dec-2018 19:42:14.778 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.778762 29.725000 140.500000 $ 12-Dec-2018 19:42:15.751 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.779962 29.725000 140.500000 $ 12-Dec-2018 19:42:16.750 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.761671 29.725000 140.500000 $ 12-Dec-2018 19:42:17.419 Anchor SBE41 Message 25.75 25.750000 25.394671 -0.023417 0.000000 -0.156667 -0.000680 3.000000 $ 12-Dec-2018 19:42:17.778 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.758601 29.725000 140.500000 $ 12-Dec-2018 19:42:18.752 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.755598 29.725000 140.500000 $ 12-Dec-2018 19:42:19.752 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.750000 157.764018 29.725000 140.500000 $ 12-Dec-2018 19:42:20.420 Anchor SBE41 Message 25.15 25.150000 25.167984 -0.031420 0.200000 0.100000 -0.000709 3.000000 $ 12-Dec-2018 19:42:20.779 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.150000 157.760397 29.725000 140.500000 $ 12-Dec-2018 19:42:21.753 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.150000 157.767005 29.725000 140.500000 $ 12-Dec-2018 19:42:22.752 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.150000 157.751866 29.725000 140.500000 $ 12-Dec-2018 19:42:23.420 Anchor SBE41 Message 24.79 24.790001 25.052060 -0.018694 0.120000 0.160000 -0.000705 3.000000 $ 12-Dec-2018 19:42:23.780 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.763898 29.725000 140.500000 $ 12-Dec-2018 19:42:24.754 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.778919 29.725000 140.500000 $ 12-Dec-2018 19:42:25.754 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.790001 157.782428 29.725000 140.500000 $ 12-Dec-2018 19:42:26.420 Anchor SBE41 Message 24.78 24.780001 25.152123 0.006634 0.003333 0.061666 -0.000716 3.000000 $ 12-Dec-2018 19:42:26.781 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.764271 29.725000 140.500000 $ 12-Dec-2018 19:42:27.755 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.770135 29.725000 140.500000 $ 12-Dec-2018 19:42:28.754 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.780001 157.779187 29.725000 140.500000 $ 12-Dec-2018 19:42:29.419 Anchor SBE41 Message 25.79 25.790001 25.332879 0.027132 -0.336667 -0.166667 -0.000689 3.000000 $ 12-Dec-2018 19:42:29.880 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.743700 29.725000 140.500000 $ 12-Dec-2018 19:42:30.754 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.768153 29.725000 140.500000 $ 12-Dec-2018 19:42:31.753 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.765657 29.725000 140.500000 $ 12-Dec-2018 19:42:32.419 Anchor SBE41 Message 25.80 25.799999 25.372636 0.026390 -0.003333 -0.170000 -0.000570 3.000000 $ 12-Dec-2018 19:42:32.780 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.799999 157.773159 29.725000 140.500000 $ 12-Dec-2018 19:42:33.754 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.799999 157.789558 29.725000 140.500000 $ 12-Dec-2018 19:42:34.752 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.799999 157.761231 29.725000 140.500000 $ 12-Dec-2018 19:42:35.418 Anchor SBE41 Message 25.26 25.260000 25.235580 0.006043 0.180000 0.088333 -0.000408 3.000000 $ 12-Dec-2018 19:42:35.784 Anchor Normal State Exit $ 12-Dec-2018 19:42:35.894 Anchor ERROR: Missed PH message 4 $ 12-Dec-2018 19:42:35.898 Anchor ERROR: Missed NO3 message 4 $ 12-Dec-2018 19:42:35.788 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.756396 29.725000 140.500000 $ 12-Dec-2018 19:42:36.550 Start CP Mode State Entry $ 12-Dec-2018 19:42:36.656 Start CP Mode Stopping SBE41 Timer $ 12-Dec-2018 19:42:36.965 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.778047 29.725000 140.500000 $ 12-Dec-2018 19:42:37.102 Start CP Mode Sending CTD PTS $ 12-Dec-2018 19:42:37.106 Start CP Mode Sending Optode Do Sample $ 12-Dec-2018 19:42:37.213 Start CP Mode Sending Optode Wakeup $ 12-Dec-2018 19:42:37.209 Start CP Mode Unparsed SBE41 Message S>pts $ 12-Dec-2018 19:42:37.876 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.759152 29.725000 140.500000 $ 12-Dec-2018 19:42:37.987 Start CP Mode Sending FLBB run command $ 12-Dec-2018 19:42:38.004 Start CP Mode Sending radiometer pollSample $ 12-Dec-2018 19:42:38.550 Start CP Mode SBE41 Timer Stopped, Sending SBE41 CR/LF $ 12-Dec-2018 19:42:38.654 Start CP Mode Radiometer Message SATFI40287,-0.0055,0.0008,-0.0062,-0.2269 $ 12-Dec-2018 19:42:38.970 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.778934 29.725000 140.500000 $ 12-Dec-2018 19:42:39.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:39.082 Start CP Mode Optode Message 4330,1532,263.671,22.667,29.130,29.060,36.110,7.050,536.7,465.2,105.0 $ 12-Dec-2018 19:42:39.082 Start CP Mode Optode Message # $ 12-Dec-2018 19:42:39.785 Start CP Mode FLBB Message /99/99,99:99:99,695,2304,700,4130,534 $ 12-Dec-2018 19:42:40.195 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.795183 29.725000 140.500000 $ 12-Dec-2018 19:42:40.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:40.757 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.769121 29.725000 140.500000 $ 12-Dec-2018 19:42:41.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:41.756 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.775544 29.725000 140.500000 $ 12-Dec-2018 19:42:42.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:42.756 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.776780 29.725000 140.500000 $ 12-Dec-2018 19:42:43.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:43.757 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.260000 157.761149 29.725000 140.500000 $ 12-Dec-2018 19:42:44.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:44.324 Start CP Mode SBE41 Message 25.79, 22.1808, 34.1838 25.790001 25.117601 -0.012759 -0.176667 0.001666 -0.000300 3.000000 $ 12-Dec-2018 19:42:44.888 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771692 29.725000 140.500000 $ 12-Dec-2018 19:42:45.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:45.854 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771222 29.725000 140.500000 $ 12-Dec-2018 19:42:46.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:46.758 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.766551 29.725000 140.500000 $ 12-Dec-2018 19:42:47.550 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:47.757 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.749265 29.725000 140.500000 $ 12-Dec-2018 19:42:48.551 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:48.759 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771647 29.725000 140.500000 $ 12-Dec-2018 19:42:49.552 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:49.758 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.753080 29.725000 140.500000 $ 12-Dec-2018 19:42:50.552 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:50.758 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.768980 29.725000 140.500000 $ 12-Dec-2018 19:42:51.552 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:51.759 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.774955 29.725000 140.500000 $ 12-Dec-2018 19:42:52.552 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:52.758 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.761142 29.725000 140.500000 $ 12-Dec-2018 19:42:53.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:53.759 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.757483 29.725000 140.500000 $ 12-Dec-2018 19:42:54.552 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:54.759 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.759652 29.725000 140.500000 $ 12-Dec-2018 19:42:55.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:55.859 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.775976 29.725000 140.500000 $ 12-Dec-2018 19:42:56.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:56.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.767281 29.725000 140.500000 $ 12-Dec-2018 19:42:57.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:57.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.780483 29.725000 140.500000 $ 12-Dec-2018 19:42:58.554 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:58.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.753542 29.725000 140.500000 $ 12-Dec-2018 19:42:59.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:42:59.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.756522 29.725000 140.500000 $ 12-Dec-2018 19:43:00.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:00.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.761209 29.725000 140.500000 $ 12-Dec-2018 19:43:01.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:01.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771364 29.725000 140.500000 $ 12-Dec-2018 19:43:02.552 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:02.760 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.756336 29.725000 140.500000 $ 12-Dec-2018 19:43:03.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:03.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.764025 29.725000 140.500000 $ 12-Dec-2018 19:43:04.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:04.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.762788 29.725000 140.500000 $ 12-Dec-2018 19:43:05.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:05.856 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.773815 29.725000 140.500000 $ 12-Dec-2018 19:43:06.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:06.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771483 29.725000 140.500000 $ 12-Dec-2018 19:43:07.553 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:07.857 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.783724 29.725000 140.500000 $ 12-Dec-2018 19:43:08.554 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:08.857 Start CP Mode PTH Message 801.558594 24.000000 54.504913 24.975979 $ 12-Dec-2018 19:43:09.059 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.776907 29.725000 140.500000 $ 12-Dec-2018 19:43:09.554 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:09.760 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.774642 29.725000 140.500000 $ 12-Dec-2018 19:43:10.555 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:10.761 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771245 29.725000 140.500000 $ 12-Dec-2018 19:43:11.554 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:11.761 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.770373 29.725000 140.500000 $ 12-Dec-2018 19:43:12.555 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:12.763 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.780699 29.725000 140.500000 $ 12-Dec-2018 19:43:13.556 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:13.762 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.756172 29.725000 140.500000 $ 12-Dec-2018 19:43:14.556 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:14.762 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.786712 29.725000 140.500000 $ 12-Dec-2018 19:43:15.556 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:15.860 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.784626 29.725000 140.500000 $ 12-Dec-2018 19:43:16.556 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:16.860 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.764815 29.725000 140.500000 $ 12-Dec-2018 19:43:17.556 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:17.860 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.781608 29.725000 140.500000 $ 12-Dec-2018 19:43:18.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:18.861 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771990 29.725000 140.500000 $ 12-Dec-2018 19:43:19.556 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:19.764 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.758333 29.725000 140.500000 $ 12-Dec-2018 19:43:20.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:20.863 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.777496 29.725000 140.500000 $ 12-Dec-2018 19:43:21.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:21.863 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.764167 29.725000 140.500000 $ 12-Dec-2018 19:43:22.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:22.861 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.767490 29.725000 140.500000 $ 12-Dec-2018 19:43:23.558 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:23.861 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.765046 29.725000 140.500000 $ 12-Dec-2018 19:43:24.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:24.861 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.779396 29.725000 140.500000 $ 12-Dec-2018 19:43:25.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:25.861 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.769702 29.725000 140.500000 $ 12-Dec-2018 19:43:26.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:26.768 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.786414 29.725000 140.500000 $ 12-Dec-2018 19:43:27.557 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:27.763 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.748088 29.725000 140.500000 $ 12-Dec-2018 19:43:28.558 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:28.766 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.759368 29.725000 140.500000 $ 12-Dec-2018 19:43:29.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:29.765 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.775611 29.725000 140.500000 $ 12-Dec-2018 19:43:30.558 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:30.862 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.774612 29.725000 140.500000 $ 12-Dec-2018 19:43:31.558 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:31.862 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.765612 29.725000 140.500000 $ 12-Dec-2018 19:43:32.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:32.863 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.776974 29.725000 140.500000 $ 12-Dec-2018 19:43:33.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:33.863 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.769419 29.725000 140.500000 $ 12-Dec-2018 19:43:34.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:34.863 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.772891 29.725000 140.500000 $ 12-Dec-2018 19:43:35.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:35.767 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.754324 29.725000 140.500000 $ 12-Dec-2018 19:43:36.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:36.766 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.746665 29.725000 140.500000 $ 12-Dec-2018 19:43:37.559 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:37.766 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.784909 29.725000 140.500000 $ 12-Dec-2018 19:43:38.560 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:38.766 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.767907 29.725000 140.500000 $ 12-Dec-2018 19:43:39.560 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:39.766 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771781 29.725000 140.500000 $ 12-Dec-2018 19:43:40.560 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:40.767 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.761835 29.725000 140.500000 $ 12-Dec-2018 19:43:41.560 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:41.766 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.774076 29.725000 140.500000 $ 12-Dec-2018 19:43:42.561 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:42.867 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.777935 29.725000 140.500000 $ 12-Dec-2018 19:43:43.561 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:43.865 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.769971 29.725000 140.500000 $ 12-Dec-2018 19:43:44.561 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:44.865 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.780804 29.725000 140.500000 $ 12-Dec-2018 19:43:45.561 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:45.865 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.755934 29.725000 140.500000 $ 12-Dec-2018 19:43:46.562 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:46.866 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.762296 29.725000 140.500000 $ 12-Dec-2018 19:43:47.562 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:47.865 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.750756 29.725000 140.500000 $ 12-Dec-2018 19:43:48.562 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:48.866 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.771766 29.725000 140.500000 $ 12-Dec-2018 19:43:49.562 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:49.770 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.766238 29.725000 140.500000 $ 12-Dec-2018 19:43:50.562 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:50.769 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.780707 29.725000 140.500000 $ 12-Dec-2018 19:43:51.562 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:51.768 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.769673 29.725000 140.500000 $ 12-Dec-2018 19:43:52.563 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:52.769 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.757416 29.725000 140.500000 $ 12-Dec-2018 19:43:53.563 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:53.769 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.760181 29.725000 140.500000 $ 12-Dec-2018 19:43:54.563 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:54.770 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.757856 29.725000 140.500000 $ 12-Dec-2018 19:43:55.563 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:55.769 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.754831 29.725000 140.500000 $ 12-Dec-2018 19:43:56.564 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:56.772 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.764316 29.725000 140.500000 $ 12-Dec-2018 19:43:57.564 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:57.771 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.779120 29.725000 140.500000 $ 12-Dec-2018 19:43:58.565 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:58.771 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.752328 29.725000 140.500000 $ 12-Dec-2018 19:43:59.566 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:43:59.772 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.751083 29.725000 140.500000 $ 12-Dec-2018 19:44:00.566 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:44:00.772 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.758392 29.725000 140.500000 $ 12-Dec-2018 19:44:01.566 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:44:01.874 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.759860 29.725000 140.500000 $ 12-Dec-2018 19:44:02.567 Start CP Mode Didn't get CR/LF response, trying again $ 12-Dec-2018 19:44:01.671 Start CP Mode Unparsed SBE41 Message S> $ 12-Dec-2018 19:44:02.890 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.780737 29.725000 140.500000 $ 12-Dec-2018 19:44:03.567 Start CP Mode Got CR/LF response, sending startprofile $ 12-Dec-2018 19:44:03.774 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.762788 29.725000 140.500000 $ 12-Dec-2018 19:44:04.568 Start CP Mode Didn't get startprofile response, retrying $ 12-Dec-2018 19:44:04.589 Start CP Mode Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:44:04.687 Start CP Mode Unparsed SBE41 Message S>startprofile5 $ 12-Dec-2018 19:44:05.013 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.765992 29.725000 140.500000 $ 12-Dec-2018 19:44:05.568 Start CP Mode Didn't get startprofile response, retrying $ 12-Dec-2018 19:44:05.671 Start CP Mode Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:44:05.975 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.765776 29.725000 140.500000 $ 12-Dec-2018 19:44:06.569 Start CP Mode Didn't get startprofile response, retrying $ 12-Dec-2018 19:44:06.672 Start CP Mode Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:44:06.976 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.752544 29.725000 140.500000 $ 12-Dec-2018 19:44:07.570 Start CP Mode Didn't get startprofile response, retrying $ 12-Dec-2018 19:44:07.673 Start CP Mode Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:44:07.976 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.779686 29.725000 140.500000 $ 12-Dec-2018 19:44:08.570 Start CP Mode Didn't get startprofile response, retrying $ 12-Dec-2018 19:44:08.672 Start CP Mode Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:44:08.465 Start CP Mode Unparsed SBE41 Message profile started, pump delay = 5 seconds $ 12-Dec-2018 19:44:09.095 Start CP Mode PTH Message 801.511719 24.041667 54.474396 24.975979 $ 12-Dec-2018 19:44:09.297 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.763861 29.700000 NaN $ 12-Dec-2018 19:44:09.569 Start CP Mode Got startprofile response $ 12-Dec-2018 19:44:09.574 Start CP Mode Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:44:09.676 Start CP Mode Starting valve open $ 12-Dec-2018 19:44:09.979 Start CP Mode Normal State Exit $ 12-Dec-2018 19:44:09.984 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.785259 29.700000 NaN $ 12-Dec-2018 19:44:10.569 DeAnchor State Entry $ 12-Dec-2018 19:44:10.574 DeAnchor Deanchor JV = 200000.0 $ 12-Dec-2018 19:44:10.680 DeAnchor Initializing SBE 41 LPF $ 12-Dec-2018 19:44:10.885 DeAnchor Starting valve open $ 12-Dec-2018 19:44:11.291 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.755896 29.700000 NaN $ 12-Dec-2018 19:44:11.774 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.754406 29.700000 NaN $ 12-Dec-2018 19:44:12.772 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.772422 29.700000 NaN $ 12-Dec-2018 19:44:13.772 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.636315 29.700000 NaN $ 12-Dec-2018 19:44:14.216 DeAnchor Unparsed SBE41 Message S> 24.80, 22.2032, 34.1832 $ 12-Dec-2018 19:44:14.914 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.790001 157.562137 29.700000 NaN $ 12-Dec-2018 19:44:15.215 DeAnchor SBE41 Message 24.80, 22.2034, 34.1846 24.799999 25.789985 0.000002 0.990002 0.495001 -0.000000 1.000000 $ 12-Dec-2018 19:44:15.805 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.799999 157.377623 29.700000 NaN $ 12-Dec-2018 19:44:16.214 DeAnchor SBE41 Message 24.81, 22.2019, 34.1857 24.809999 25.787066 0.000363 -0.010000 0.490001 0.000011 1.000000 $ 12-Dec-2018 19:44:16.805 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 157.130815 29.700000 NaN $ 12-Dec-2018 19:44:17.212 DeAnchor SBE41 Message 24.81, 22.2002, 34.1866 24.809999 25.759198 0.003808 0.000000 -0.005000 0.000092 1.000000 $ 12-Dec-2018 19:44:17.806 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.809999 156.996123 29.700000 NaN $ 12-Dec-2018 19:44:18.212 DeAnchor SBE41 Message 25.38, 22.1999, 34.1855 25.379999 25.653585 0.016864 -0.570000 -0.285000 0.000361 1.000000 $ 12-Dec-2018 19:44:18.810 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.379999 156.874932 29.700000 NaN $ 12-Dec-2018 19:44:19.210 DeAnchor SBE41 Message 25.66, 22.2016, 34.1854 25.660000 25.436750 0.043674 -0.280001 -0.425000 0.000909 1.000000 $ 12-Dec-2018 19:44:19.805 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 156.675875 29.700000 NaN $ 12-Dec-2018 19:44:20.210 DeAnchor SBE41 Message 25.68, 22.2023, 34.1851 25.680000 25.178508 0.075615 -0.020000 -0.150001 0.001671 1.000000 $ 12-Dec-2018 19:44:20.901 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 156.486578 29.700000 NaN $ 12-Dec-2018 19:44:21.209 DeAnchor SBE41 Message 25.66, 22.2043, 34.1854 25.660000 25.030643 0.093924 0.020000 0.000000 0.002420 1.000000 $ 12-Dec-2018 19:44:21.908 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.660000 156.425722 29.700000 NaN $ 12-Dec-2018 19:44:22.208 DeAnchor SBE41 Message 25.67, 22.2059, 34.1852 25.670000 25.083845 0.087377 -0.010000 0.005000 0.002931 1.000000 $ 12-Dec-2018 19:44:22.804 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.670000 156.135529 29.700000 NaN $ 12-Dec-2018 19:44:23.207 DeAnchor SBE41 Message 25.67, 22.2066, 34.1850 25.670000 25.280414 0.063085 0.000000 -0.005000 0.003132 1.000000 $ 12-Dec-2018 19:44:23.804 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.670000 155.949071 29.700000 NaN $ 12-Dec-2018 19:44:24.206 DeAnchor SBE41 Message 25.33, 22.2066, 34.1861 25.330000 25.485222 0.037384 0.340000 0.170000 0.003102 1.000000 $ 12-Dec-2018 19:44:24.805 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.330000 155.816421 29.700000 NaN $ 12-Dec-2018 19:44:25.205 DeAnchor SBE41 Message 24.21, 22.2073, 34.1862 24.209999 25.609533 0.018522 1.120001 0.730000 0.002970 1.000000 $ 12-Dec-2018 19:44:25.805 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.209999 155.691400 29.700000 NaN $ 12-Dec-2018 19:44:26.204 DeAnchor SBE41 Message 24.17, 22.2074, 34.1867 24.170000 25.643715 0.001185 0.039999 0.580000 0.002832 1.000000 $ 12-Dec-2018 19:44:26.900 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.170000 155.416720 29.700000 NaN $ 12-Dec-2018 19:44:27.204 DeAnchor SBE41 Message 24.18, 22.2082, 34.1865 24.180000 25.585741 -0.018490 -0.010000 0.014999 0.002756 1.000000 $ 12-Dec-2018 19:44:27.804 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.180000 155.333795 29.700000 NaN $ 12-Dec-2018 19:44:28.202 DeAnchor SBE41 Message 24.18, 22.2089, 34.1864 24.180000 25.390896 -0.026329 0.000000 -0.005000 0.002827 1.000000 $ 12-Dec-2018 19:44:28.903 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.180000 155.073762 29.700000 NaN $ 12-Dec-2018 19:44:29.201 DeAnchor SBE41 Message 24.17, 22.2090, 34.1868 24.170000 25.043792 -0.001667 0.010000 0.005000 0.003118 1.000000 $ 12-Dec-2018 19:44:29.804 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.170000 154.903926 29.700000 NaN $ 12-Dec-2018 19:44:30.199 DeAnchor SBE41 Message 24.17, 22.2100, 34.1867 24.170000 24.647001 0.054017 0.000000 0.005000 0.003624 1.000000 $ 12-Dec-2018 19:44:30.901 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.170000 154.686458 29.700000 NaN $ 12-Dec-2018 19:44:31.199 DeAnchor SBE41 Message 24.17, 22.2107, 34.1864 24.170000 24.352965 0.114731 0.000000 0.000000 0.004251 1.000000 $ 12-Dec-2018 19:44:31.903 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.170000 154.579282 29.700000 NaN $ 12-Dec-2018 19:44:32.198 DeAnchor SBE41 Message 24.17, 22.2109, 34.1867 24.170000 24.216434 0.156981 0.000000 0.000000 0.004893 1.000000 $ 12-Dec-2018 19:44:32.902 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.170000 154.347137 29.700000 NaN $ 12-Dec-2018 19:44:33.198 DeAnchor SBE41 Message 24.18, 22.2116, 34.1866 24.180000 24.179591 0.176930 -0.010000 -0.005000 0.005496 1.000000 $ 12-Dec-2018 19:44:33.806 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.180000 154.201239 29.700000 NaN $ 12-Dec-2018 19:44:34.195 DeAnchor SBE41 Message 24.18, 22.2127, 34.1863 24.180000 24.173454 0.181908 0.000000 -0.005000 0.006049 1.000000 $ 12-Dec-2018 19:44:34.903 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.180000 154.029809 29.700000 NaN $ 12-Dec-2018 19:44:35.195 DeAnchor SBE41 Message 24.19, 22.2123, 34.1871 24.190001 24.171664 0.174926 -0.010000 -0.005000 0.006559 1.000000 $ 12-Dec-2018 19:44:35.905 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.190001 153.855555 29.700000 NaN $ 12-Dec-2018 19:44:36.194 DeAnchor SBE41 Message 24.24, 22.2128, 34.1872 24.240000 24.171723 0.150784 -0.049999 -0.030000 0.007032 1.000000 $ 12-Dec-2018 19:44:36.807 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.240000 153.626010 29.700000 NaN $ 12-Dec-2018 19:44:37.193 DeAnchor SBE41 Message 24.26, 22.2136, 34.1870 24.260000 24.174089 0.107542 -0.020000 -0.035000 0.007473 1.000000 $ 12-Dec-2018 19:44:37.898 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.260000 153.489873 29.700000 NaN $ 12-Dec-2018 19:44:38.192 DeAnchor SBE41 Message 24.27, 22.2144, 34.1868 24.270000 24.179399 0.057812 -0.010000 -0.015000 0.007886 1.000000 $ 12-Dec-2018 19:44:38.810 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 153.320245 29.700000 NaN $ 12-Dec-2018 19:44:39.190 DeAnchor SBE41 Message 24.27, 22.2147, 34.1871 24.270000 24.189777 0.020173 0.000000 -0.005000 0.008273 1.000000 $ 12-Dec-2018 19:44:39.807 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 153.145261 29.700000 NaN $ 12-Dec-2018 19:44:40.190 DeAnchor SBE41 Message 24.27, 22.2149, 34.1874 24.270000 24.207160 0.001145 0.000000 0.000000 0.008637 1.000000 $ 12-Dec-2018 19:44:40.807 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 152.958542 29.700000 NaN $ 12-Dec-2018 19:44:41.188 DeAnchor SBE41 Message 24.27, 22.2165, 34.1867 24.270000 24.229173 -0.006132 0.000000 0.000000 0.008981 1.000000 $ 12-Dec-2018 19:44:41.809 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 152.790762 29.700000 NaN $ 12-Dec-2018 19:44:42.188 DeAnchor SBE41 Message 24.27, 22.2162, 34.1873 24.270000 24.249184 -0.009367 0.000000 0.000000 0.009310 1.000000 $ 12-Dec-2018 19:44:42.811 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 152.695596 29.700000 NaN $ 12-Dec-2018 19:44:43.186 DeAnchor SBE41 Message 24.27, 22.2172, 34.1870 24.270000 24.262052 -0.011181 0.000000 0.000000 0.009633 1.000000 $ 12-Dec-2018 19:44:43.809 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 152.436964 29.700000 NaN $ 12-Dec-2018 19:44:44.186 DeAnchor SBE41 Message 24.27, 22.2177, 34.1871 24.270000 24.267848 -0.011892 0.000000 0.000000 0.009961 1.000000 $ 12-Dec-2018 19:44:44.809 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.270000 152.209818 29.700000 NaN $ 12-Dec-2018 19:44:45.184 DeAnchor SBE41 Message 24.00, 22.2191, 34.1836 24.000000 24.269625 -0.011820 0.270000 0.135000 0.010301 1.000000 $ 12-Dec-2018 19:44:45.909 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.000000 152.043626 29.700000 NaN $ 12-Dec-2018 19:44:46.183 DeAnchor SBE41 Message 23.05, 22.2194, 34.1867 23.049999 24.269155 -0.011104 0.950001 0.610001 0.010667 1.000000 $ 12-Dec-2018 19:44:46.811 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.049999 151.839294 29.700000 NaN $ 12-Dec-2018 19:44:47.183 DeAnchor SBE41 Message 22.93, 22.2196, 34.1873 22.930000 24.258773 -0.008535 0.119999 0.535000 0.011079 1.000000 $ 12-Dec-2018 19:44:47.810 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.930000 151.775613 29.700000 NaN $ 12-Dec-2018 19:44:48.182 DeAnchor SBE41 Message 22.92, 22.2198, 34.1876 22.920000 24.202766 0.000540 0.010000 0.065000 0.011586 1.000000 $ 12-Dec-2018 19:44:48.810 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.920000 151.546814 29.700000 NaN $ 12-Dec-2018 19:44:49.180 DeAnchor SBE41 Message 22.92, 22.2208, 34.1871 22.920000 24.037842 0.023652 0.000000 0.005000 0.012294 1.000000 $ 12-Dec-2018 19:44:49.910 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.920000 151.371866 29.700000 NaN $ 12-Dec-2018 19:44:50.180 DeAnchor SBE41 Message 22.94, 22.2216, 34.1870 22.940001 23.738366 0.063158 -0.020000 -0.010000 0.013392 1.000000 $ 12-Dec-2018 19:44:50.811 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.940001 151.166841 29.700000 NaN $ 12-Dec-2018 19:44:51.179 DeAnchor SBE41 Message 22.92, 22.2212, 34.1875 22.920000 23.384707 0.108493 0.020000 0.000000 0.015188 1.000000 $ 12-Dec-2018 19:44:51.811 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.920000 151.014365 29.700000 NaN $ 12-Dec-2018 19:44:52.178 DeAnchor SBE41 Message 22.91, 22.2216, 34.1875 22.910000 23.109776 0.143237 0.010000 0.015000 0.018360 1.000000 $ 12-Dec-2018 19:44:52.911 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.910000 150.874995 29.700000 NaN $ 12-Dec-2018 19:44:53.176 DeAnchor SBE41 Message 22.94, 22.2220, 34.1879 22.940001 22.972671 0.160447 -0.030001 -0.010000 0.025450 1.000000 $ 12-Dec-2018 19:44:53.813 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.940001 150.668837 29.700000 NaN $ 12-Dec-2018 19:44:54.578 DeAnchor Deanchor velocity (slope) threshold exceeded $ 12-Dec-2018 19:44:54.176 DeAnchor SBE41 Message 22.93, 22.2232, 34.1873 22.930000 22.932153 0.165423 0.010000 -0.010000 0.061937 1.000000 $ 12-Dec-2018 19:44:55.011 DeAnchor Normal State Exit $ 12-Dec-2018 19:44:55.113 DeAnchor RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.930000 150.461487 29.700000 NaN $ 12-Dec-2018 19:44:55.578 Ascend State Entry $ 12-Dec-2018 19:44:55.694 Ascend Starting valve open $ 12-Dec-2018 19:44:55.698 Ascend Skipping ascend table depth = 100 $ 12-Dec-2018 19:44:55.898 Ascend Skipping ascend table depth = 95 $ 12-Dec-2018 19:44:56.001 Ascend Skipping ascend table depth = 90 $ 12-Dec-2018 19:44:56.103 Ascend Skipping ascend table depth = 85 $ 12-Dec-2018 19:44:56.109 Ascend Skipping ascend table depth = 80 $ 12-Dec-2018 19:44:56.212 Ascend Skipping ascend table depth = 75 $ 12-Dec-2018 19:44:56.314 Ascend Skipping ascend table depth = 70 $ 12-Dec-2018 19:44:56.416 Ascend Skipping ascend table depth = 65 $ 12-Dec-2018 19:44:56.519 Ascend Skipping ascend table depth = 60 $ 12-Dec-2018 19:44:56.621 Ascend Skipping ascend table depth = 55 $ 12-Dec-2018 19:44:56.723 Ascend Skipping ascend table depth = 50 $ 12-Dec-2018 19:44:56.825 Ascend Skipping ascend table depth = 45 $ 12-Dec-2018 19:44:57.026 Ascend Skipping ascend table depth = 40 $ 12-Dec-2018 19:44:57.128 Ascend Skipping ascend table depth = 35 $ 12-Dec-2018 19:44:57.231 Ascend Skipping ascend table depth = 30 $ 12-Dec-2018 19:44:57.333 Ascend Skipping ascend table depth = 25 $ 12-Dec-2018 19:44:57.436 Ascend Starting ISUS sample $ 12-Dec-2018 19:44:57.539 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 12-Dec-2018 19:44:57.644 Ascend MSC: OUT: W $ 12-Dec-2018 19:44:57.899 Ascend MSC: OUT: W $ 12-Dec-2018 19:44:55.229 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 0.287841 4.800014 4.800014 39321.000000 1.000000 $ 12-Dec-2018 19:44:55.229 Ascend SBE41 Message 22.94, 22.2237, 34.1873 22.940001 22.925809 0.164920 -0.010000 0.000000 0.063216 1.000000 $ 12-Dec-2018 19:44:58.551 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.940001 150.294624 29.700000 NaN $ 12-Dec-2018 19:44:58.666 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0875267 $ 12-Dec-2018 19:44:56.207 Ascend Vel PID Values 0.050000 0.020000 0.019901 0.029868 0.432318 2.687823 2.687823 22018.000000 1.000000 $ 12-Dec-2018 19:44:56.207 Ascend SBE41 Message 22.92, 22.2245, 34.1862 22.920000 22.924730 0.158100 0.020000 0.005000 0.063975 1.000000 $ 12-Dec-2018 19:44:57.231 Ascend Vel PID Values 0.050000 -0.010000 -0.009901 -0.029801 0.719841 5.232310 5.232310 42863.000000 1.000000 $ 12-Dec-2018 19:44:57.231 Ascend SBE41 Message 22.93, 22.2245, 34.1877 22.930000 22.925408 0.137586 -0.010000 0.005000 0.064297 1.000000 $ 12-Dec-2018 19:44:59.360 Ascend MSC: RX: $ 12-Dec-2018 19:44:59.559 Ascend MSC: RX: $ 12-Dec-2018 19:44:59.661 Ascend MSC: RX: ACK $ 12-Dec-2018 19:44:59.667 Ascend MSC: Got ACK $ 12-Dec-2018 19:44:59.970 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.930000 150.250532 29.700000 NaN $ 12-Dec-2018 19:45:00.080 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4092098 $ 12-Dec-2018 19:44:58.234 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019834 0.912158 3.919845 3.919845 32111.000000 1.000000 $ 12-Dec-2018 19:44:58.234 Ascend SBE41 Message 22.92, 22.2256, 34.1872 22.920000 22.928336 0.100165 0.010000 0.000000 0.064481 1.000000 $ 12-Dec-2018 19:44:59.171 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019868 1.199841 5.712159 5.712159 46794.000000 1.000000 $ 12-Dec-2018 19:44:59.171 Ascend SBE41 Message 22.93, 22.2262, 34.1872 22.930000 22.930945 0.056101 -0.010000 0.000000 0.064993 1.000000 $ 12-Dec-2018 19:45:00.184 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009901 1.440000 5.199854 5.199854 42597.000000 1.000000 $ 12-Dec-2018 19:45:00.184 Ascend SBE41 Message 22.93, 22.2257, 34.1880 22.930000 22.930779 0.022128 0.000000 -0.005000 0.066025 1.000000 $ 12-Dec-2018 19:45:01.323 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.930000 150.187626 29.700000 NaN $ 12-Dec-2018 19:45:01.435 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3490682 $ 12-Dec-2018 19:45:01.539 Ascend MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 12-Dec-2018 19:45:01.855 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.930000 150.128871 29.700000 NaN $ 12-Dec-2018 19:45:01.219 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 1.680000 5.439995 5.439995 44564.000000 1.000000 $ 12-Dec-2018 19:45:01.219 Ascend SBE41 Message 22.93, 22.2268, 34.1873 22.930000 22.928570 0.005451 0.000000 0.000000 0.067202 1.000000 $ 12-Dec-2018 19:45:02.688 Ascend MSC: RX: NAK,CTD,EConvertErr: 0 $ 12-Dec-2018 19:45:02.888 Ascend MSC: EConvertErr: 0 $ 12-Dec-2018 19:45:02.168 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000000 1.920000 5.680000 5.680000 46530.000000 1.000000 $ 12-Dec-2018 19:45:02.168 Ascend SBE41 Message 22.93, 22.2269, 34.1877 22.930000 22.926663 0.000678 0.000000 0.000000 0.067801 1.000000 $ 12-Dec-2018 19:45:03.538 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.930000 150.088809 29.700000 NaN $ 12-Dec-2018 19:45:03.648 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2078538 $ 12-Dec-2018 19:45:03.220 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 2.207841 6.720014 6.720014 55050.000000 1.000000 $ 12-Dec-2018 19:45:03.220 Ascend SBE41 Message 22.94, 22.2276, 34.1875 22.940001 22.926411 -0.000075 -0.010000 -0.005000 0.067227 1.000000 $ 12-Dec-2018 19:45:04.300 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.940001 149.992585 29.700000 NaN $ 12-Dec-2018 19:45:04.654 Ascend MSC: OUT: W $ 12-Dec-2018 19:45:05.008 Ascend MSC: OUT: W $ 12-Dec-2018 19:45:04.166 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 2.400160 5.407836 5.407836 44300.000000 1.000000 $ 12-Dec-2018 19:45:04.166 Ascend SBE41 Message 22.93, 22.2279, 34.1877 22.930000 22.927559 -0.000350 0.010000 0.000000 0.065434 1.000000 $ 12-Dec-2018 19:45:05.452 Ascend MSC: RX: ACK $ 12-Dec-2018 19:45:05.456 Ascend MSC: Got ACK $ 12-Dec-2018 19:45:05.657 Ascend MSC: RX: ACK $ 12-Dec-2018 19:45:05.661 Ascend MSC: Got ACK $ 12-Dec-2018 19:45:05.164 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019868 2.687842 7.200160 7.200160 58983.000000 1.000000 $ 12-Dec-2018 19:45:05.164 Ascend SBE41 Message 22.94, 22.2287, 34.1874 22.940001 22.929183 -0.000466 -0.010000 0.000000 0.062679 1.000000 $ 12-Dec-2018 19:45:06.407 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.940001 149.927720 29.700000 NaN $ 12-Dec-2018 19:45:06.519 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8657585 $ 12-Dec-2018 19:45:06.623 Ascend MSC: OUT: MODE,1 $ 12-Dec-2018 19:45:06.205 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019868 2.880160 5.887841 5.887841 48233.000000 1.000000 $ 12-Dec-2018 19:45:06.205 Ascend SBE41 Message 22.93, 22.2292, 34.1874 22.930000 22.930818 -0.000306 0.010000 0.000000 0.059271 1.000000 $ 12-Dec-2018 19:45:07.275 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.930000 149.847932 29.700000 NaN $ 12-Dec-2018 19:45:07.526 Ascend MSC: RX: ACK,MODE,1 $ 12-Dec-2018 19:45:07.162 Ascend Vel PID Values 0.050000 0.740000 0.737570 0.727637 69.165048 -52.319508 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:07.162 Ascend SBE41 Message 22.19, 22.2292, 34.1879 22.190001 22.932459 -0.000187 0.740000 0.375000 0.055583 1.000000 $ 12-Dec-2018 19:45:08.176 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 22.190001 149.783276 29.700000 NaN $ 12-Dec-2018 19:45:08.161 Ascend Vel PID Values 0.050000 0.590000 0.590495 -0.147075 66.570671 25.964647 25.964647 212702.000000 1.000000 $ 12-Dec-2018 19:45:08.161 Ascend SBE41 Message 21.60, 22.2296, 34.1882 21.600000 22.931668 -0.000111 0.590000 0.665000 0.052149 1.000000 $ 12-Dec-2018 19:45:09.073 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.600000 149.755433 29.700000 NaN $ 12-Dec-2018 19:45:09.526 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:45:09.183 Ascend Vel PID Values 0.050000 -0.010000 -0.008003 -0.598498 -574.265578 71.370489 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:09.183 Ascend SBE41 Message 21.61, 22.2300, 34.1878 21.610001 22.909641 0.002339 -0.010000 0.290000 0.049663 1.000000 $ 12-Dec-2018 19:45:10.177 Ascend PTH Message 801.255127 24.158333 54.337067 24.975979 $ 12-Dec-2018 19:45:10.379 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.610001 149.761021 28.350000 186.500000 $ 12-Dec-2018 19:45:10.159 Ascend Vel PID Values 0.050000 -0.019999 -0.019962 -0.011959 14986.033234 -568.665433 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:10.159 Ascend SBE41 Message 21.63, 22.2303, 34.1881 21.629999 22.813319 0.014010 -0.019999 -0.014999 0.048661 1.000000 $ 12-Dec-2018 19:45:11.071 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.629999 149.768375 28.350000 186.500000 $ 12-Dec-2018 19:45:11.526 Ascend MSC: OUT: TS $ 12-Dec-2018 19:45:11.183 Ascend Vel PID Values 0.050000 0.009998 0.009899 0.029860 -433190.775883 14989.233387 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:11.183 Ascend SBE41 Message 21.62, 22.2313, 34.1878 21.620001 22.585037 0.042204 0.009998 -0.005000 0.049275 1.000000 $ 12-Dec-2018 19:45:12.180 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.622366 28.350000 186.500000 $ 12-Dec-2018 19:45:12.526 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:45:12.157 Ascend Vel PID Values 0.050000 -0.009998 -0.009932 -0.019830 12560888.792963 -433185.976039 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:12.157 Ascend SBE41 Message 21.63, 22.2317, 34.1879 21.629999 22.247063 0.084142 -0.009998 0.000000 0.051323 1.000000 $ 12-Dec-2018 19:45:13.177 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.629999 149.618119 28.350000 186.500000 $ 12-Dec-2018 19:45:13.155 Ascend Vel PID Values 0.050000 0.009998 0.009932 0.019864 -364264370.808145 12560891.993114 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:13.155 Ascend SBE41 Message 21.62, 22.2321, 34.1879 21.620001 21.920925 0.124693 0.009998 0.000000 0.054337 1.000000 $ 12-Dec-2018 19:45:14.074 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.608076 28.350000 186.500000 $ 12-Dec-2018 19:45:14.184 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009899 10563665133.676455 -364264366.808159 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:14.184 Ascend SBE41 Message 21.62, 22.2323, 34.1882 21.620001 21.717066 0.150139 0.000000 0.004999 0.057694 1.000000 $ 12-Dec-2018 19:45:15.072 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.602741 28.350000 186.500000 $ 12-Dec-2018 19:45:15.183 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 -306346287496.377320 10563665137.676458 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:15.183 Ascend SBE41 Message 21.62, 22.2332, 34.1879 21.620001 21.639460 0.159971 0.000000 0.000000 0.060881 1.000000 $ 12-Dec-2018 19:45:16.073 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.607703 28.350000 186.500000 $ 12-Dec-2018 19:45:16.184 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009967 8884042335799.132800 -306346287493.177310 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:16.184 Ascend SBE41 Message 21.61, 22.2336, 34.1882 21.610001 21.624504 0.161734 0.010000 0.005000 0.063646 1.000000 $ 12-Dec-2018 19:45:17.071 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.610001 149.608843 28.350000 186.500000 $ 12-Dec-2018 19:45:17.182 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019901 -257637227736818.590000 8884042335803.933600 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:17.182 Ascend SBE41 Message 21.62, 22.2339, 34.1884 21.620001 21.623510 0.159117 -0.010000 0.000000 0.065928 1.000000 $ 12-Dec-2018 19:45:18.072 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.599172 28.350000 186.500000 $ 12-Dec-2018 19:45:18.184 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009901 7471479604366120.000000 -257637227736814.590000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:18.184 Ascend SBE41 Message 21.62, 22.2348, 34.1881 21.620001 21.622189 0.147335 0.000000 -0.005000 0.067716 1.000000 $ 12-Dec-2018 19:45:18.868 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:45:19.172 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.598524 28.350000 186.500000 $ 12-Dec-2018 19:45:19.150 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.010000 -216672908526616060.000000 7471479604366123.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:19.150 Ascend SBE41 Message 21.61, 22.2354, 34.1881 21.610001 21.620030 0.119339 0.010000 0.005000 0.069000 1.000000 $ 12-Dec-2018 19:45:20.070 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.610001 149.606392 28.350000 186.500000 $ 12-Dec-2018 19:45:20.524 Ascend MSC: OUT: SL $ 12-Dec-2018 19:45:20.182 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019901 6283514347271864300.000000 -216672908526616060.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:20.182 Ascend SBE41 Message 21.62, 22.2358, 34.1882 21.620001 21.618035 0.077776 -0.010000 0.000000 0.069734 1.000000 $ 12-Dec-2018 19:45:21.401 Ascend Error in I2CPortBase.Execute $ 12-Dec-2018 19:45:21.405 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.606392 28.350000 186.500000 $ 12-Dec-2018 19:45:21.614 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0908358 $ 12-Dec-2018 19:45:21.919 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.613090 28.350000 186.500000 $ 12-Dec-2018 19:45:22.621 Ascend MSC: RX: 0x2999,A,01/31/2012 02:10:23,0,-1.00,-1.0000,-1.0000,228,147,1,65,23.23,56.54,11.576,5.238e-01,10552.00,2245.00,1194.98,12.89,-2E5F9F66696CFE72617637785B78C177B2751E71786D6C6942657662285FAA5E075D525D495E82604762A565F369E46EA873CF79557F5B85328AAB8FC193D59687981F97F8961792A18E3888B082357BB3753F6F6669B9649D60075C0658AB55E9536E515F4FD84EBC4E1E4DC64DCF,6651.6 $ 12-Dec-2018 19:45:22.730 Ascend MSC: Data: 0x2999,A,01/31/2012 02:10:23,0,-1.00,-1.0000,-1.0000,228,147,1,65,23.23,56.54,11.576,5.238e-01,10552.00,2245.00,1194.98,12.89,-2E5F9F66696CFE72617637785B78C177B2751E71786D6C6942657662285FAA5E075D525D495E82604762A565F369E46EA873CF79557F5B85328AAB8FC193D59687981F97F8961792A18E3888B082357BB3753F6F6669B9649D60075C0658AB55E9536E515F4FD84EBC4E1E4DC64DCF,6651.6 $ 12-Dec-2018 19:45:21.760 Ascend Vel PID Values 0.050000 -0.009998 -0.009998 -0.000064 -182221916070884080000.000000 6283514347271864300.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:21.760 Ascend SBE41 Message 21.63, 22.2366, 34.1879 21.629999 21.616947 0.037580 -0.009998 -0.009999 0.069742 1.000000 $ 12-Dec-2018 19:45:22.147 Ascend Vel PID Values 0.050000 0.009998 0.009932 0.019930 5284435566055638700000.000000 -182221916070884080000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:22.147 Ascend SBE41 Message 21.62, 22.2369, 34.1880 21.620001 21.616743 0.012402 0.009998 0.000000 0.069362 1.000000 $ 12-Dec-2018 19:45:23.186 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009899 -153248631415613520000000.000000 5284435566055638700000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:23.186 Ascend SBE41 Message 21.62, 22.2371, 34.1881 21.620001 21.616995 0.002778 0.000000 0.004999 0.068428 1.000000 $ 12-Dec-2018 19:45:24.081 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 149.597973 28.350000 186.500000 $ 12-Dec-2018 19:45:24.193 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5734530 $ 12-Dec-2018 19:45:24.199 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:45:24.300 Ascend Starting pH sample $ 12-Dec-2018 19:45:24.499 Ascend MSC: OUT: W $ 12-Dec-2018 19:45:24.856 Ascend MSC: OUT: W $ 12-Dec-2018 19:45:24.191 Ascend Vel PID Values 0.050000 -0.009998 -0.009965 -0.009998 4444210311052792100000000.000000 -153248631415613520000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:24.191 Ascend SBE41 Message 21.63, 22.2376, 34.1879 21.629999 21.617987 0.000806 -0.009998 -0.004999 0.066972 1.000000 $ 12-Dec-2018 19:45:25.208 Ascend MSC: RX: ACK $ 12-Dec-2018 19:45:25.408 Ascend MSC: Got ACK $ 12-Dec-2018 19:45:25.191 Ascend Vel PID Values 0.050000 0.009998 0.009932 0.019897 -128882099020530980000000000.000000 4444210311052792100000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:25.191 Ascend SBE41 Message 21.62, 22.2379, 34.1881 21.620001 21.620000 0.000434 0.009998 0.000000 0.065005 1.000000 $ 12-Dec-2018 19:45:25.855 Ascend MSC: RX: ACK $ 12-Dec-2018 19:45:25.859 Ascend MSC: Got ACK $ 12-Dec-2018 19:45:26.267 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 150.216438 28.350000 186.500000 $ 12-Dec-2018 19:45:26.378 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1793455 $ 12-Dec-2018 19:45:26.482 Ascend MSC: OUT: MODE,2 $ 12-Dec-2018 19:45:26.142 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009899 3737580871595398300000000000.000000 -128882099020530980000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:26.142 Ascend SBE41 Message 21.62, 22.2379, 34.1885 21.620001 21.622014 0.000022 0.000000 0.004999 0.062550 1.000000 $ 12-Dec-2018 19:45:27.137 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.620001 150.226094 28.350000 186.500000 $ 12-Dec-2018 19:45:27.385 Ascend MSC: RX: ACK,MODE,2 $ 12-Dec-2018 19:45:27.247 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009934 -108389845276266560000000000000.000000 3737580871595398300000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:27.247 Ascend SBE41 Message 21.61, 22.2388, 34.1881 21.610001 21.623006 -0.000368 0.010000 0.005000 0.059605 1.000000 $ 12-Dec-2018 19:45:28.037 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.610001 150.217712 28.350000 186.500000 $ 12-Dec-2018 19:45:28.149 Ascend Vel PID Values 0.050000 0.050001 0.049868 0.039901 3143305513011730200000000000000.000000 -108389845276266560000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:28.149 Ascend SBE41 Message 21.56, 22.2389, 34.1883 21.559999 21.623228 -0.000643 0.050001 0.030001 0.056408 1.000000 $ 12-Dec-2018 19:45:28.931 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.559999 150.218792 28.350000 186.500000 $ 12-Dec-2018 19:45:29.386 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:45:29.140 Ascend Vel PID Values 0.050000 0.900000 0.897171 0.847303 -91155859877340175000000000000000.000000 3143305513011730200000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:29.140 Ascend SBE41 Message 20.66, 22.2391, 34.1886 20.660000 21.622610 -0.000701 0.900000 0.475000 0.053363 1.000000 $ 12-Dec-2018 19:45:30.039 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.660000 150.209792 28.350000 186.500000 $ 12-Dec-2018 19:45:30.149 Ascend Vel PID Values 0.050000 0.369999 0.371758 -0.525413 2643519936442865000000000000000000.000000 -91155859877340175000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:30.149 Ascend SBE41 Message 20.29, 22.2392, 34.1890 20.290001 21.616636 0.000012 0.369999 0.634999 0.051034 1.000000 $ 12-Dec-2018 19:45:30.936 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.290001 150.204681 28.350000 186.500000 $ 12-Dec-2018 19:45:31.387 Ascend MSC: OUT: TS $ 12-Dec-2018 19:45:31.138 Ascend Vel PID Values 0.050000 -0.009998 -0.008731 -0.380489 -76662078156843087000000000000000000.000000 2643519936442865000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:31.138 Ascend SBE41 Message 20.30, 22.2402, 34.1886 20.299999 21.581439 0.004395 -0.009998 0.180000 0.049796 1.000000 $ 12-Dec-2018 19:45:31.836 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:45:32.140 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.226079 28.350000 186.500000 $ 12-Dec-2018 19:45:32.136 Ascend Vel PID Values 0.050000 0.009998 0.009934 0.018665 2223200266548449500000000000000000000.000000 -76662078156843087000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:32.136 Ascend SBE41 Message 20.29, 22.2400, 34.1892 20.290001 21.460085 0.019520 0.009998 0.000000 0.049720 1.000000 $ 12-Dec-2018 19:45:32.935 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.290001 150.215603 28.350000 186.500000 $ 12-Dec-2018 19:45:33.136 Ascend Vel PID Values 0.050000 -0.009998 -0.009932 -0.019866 -64472807729905032000000000000000000000.000000 2223200266548449500000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:33.136 Ascend SBE41 Message 20.30, 22.2411, 34.1872 20.299999 21.204653 0.051352 -0.009998 0.000000 0.050795 1.000000 $ 12-Dec-2018 19:45:33.937 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.232606 28.350000 186.500000 $ 12-Dec-2018 19:45:34.134 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009899 1869711424167245900000000000000000000000.000000 -64472807729905032000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:34.134 Ascend SBE41 Message 20.30, 22.2411, 34.1890 20.299999 20.859077 0.094340 0.000000 -0.004999 0.052959 1.000000 $ 12-Dec-2018 19:45:34.939 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.311999 28.350000 186.500000 $ 12-Dec-2018 19:45:35.133 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 -54221631300850133000000000000000000000000.000000 1869711424167245900000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:35.133 Ascend SBE41 Message 20.30, 22.2415, 34.1889 20.299999 20.551595 0.132509 0.000000 0.000000 0.055869 1.000000 $ 12-Dec-2018 19:45:35.938 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.314204 28.350000 186.500000 $ 12-Dec-2018 19:45:36.133 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000000 1572427307724653900000000000000000000000000.000000 -54221631300850133000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:36.133 Ascend SBE41 Message 20.30, 22.2420, 34.1887 20.299999 20.373465 0.154599 0.000000 0.000000 0.058995 1.000000 $ 12-Dec-2018 19:45:36.938 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.400549 28.350000 186.500000 $ 12-Dec-2018 19:45:37.132 Ascend Vel PID Values 0.050000 0.009998 0.009965 0.009965 -45600391924014962000000000000000000000000000.000000 1572427307724653900000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:37.132 Ascend SBE41 Message 20.29, 22.2420, 34.1891 20.290001 20.310009 0.162399 0.009998 0.004999 0.061866 1.000000 $ 12-Dec-2018 19:45:37.937 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.290001 150.398321 28.350000 186.500000 $ 12-Dec-2018 19:45:38.130 Ascend Vel PID Values 0.050000 -0.019999 -0.019899 -0.029864 1322411365796433800000000000000000000000000000.000000 -45600391924014962000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:38.130 Ascend SBE41 Message 20.31, 22.2427, 34.1887 20.309999 20.298552 0.163083 -0.019999 -0.005000 0.064275 1.000000 $ 12-Dec-2018 19:45:38.955 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.309999 150.517784 28.350000 186.500000 $ 12-Dec-2018 19:45:39.130 Ascend Vel PID Values 0.050000 0.010000 0.009901 0.029799 -38349929608096582000000000000000000000000000000.000000 1322411365796433800000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:39.130 Ascend SBE41 Message 20.30, 22.2434, 34.1887 20.299999 20.298654 0.158697 0.010000 -0.004999 0.066200 1.000000 $ 12-Dec-2018 19:45:39.954 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.522284 28.350000 186.500000 $ 12-Dec-2018 19:45:40.127 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009867 1112147958634800700000000000000000000000000000000.000000 -38349929608096582000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:40.127 Ascend SBE41 Message 20.30, 22.2434, 34.1890 20.299999 20.298930 0.143622 0.000000 0.005000 0.067626 1.000000 $ 12-Dec-2018 19:45:40.955 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.564477 28.350000 186.500000 $ 12-Dec-2018 19:45:41.127 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010000 -32252290800409221000000000000000000000000000000000.000000 1112147958634800700000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:41.127 Ascend SBE41 Message 20.31, 22.2439, 34.1889 20.309999 20.298822 0.112018 -0.010000 -0.005000 0.068557 1.000000 $ 12-Dec-2018 19:45:41.954 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.309999 150.603473 28.350000 186.500000 $ 12-Dec-2018 19:45:42.405 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:45:42.126 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 935316433211867450000000000000000000000000000000000.000000 -32252290800409221000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:42.126 Ascend SBE41 Message 20.30, 22.2440, 34.1891 20.299999 20.299446 0.069194 0.010000 0.000000 0.069013 1.000000 $ 12-Dec-2018 19:45:43.057 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.683135 28.350000 186.500000 $ 12-Dec-2018 19:45:43.168 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 -27124176563144160000000000000000000000000000000000000.000000 935316433211867450000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:43.168 Ascend SBE41 Message 20.30, 22.2452, 34.1886 20.299999 20.300865 0.030997 0.000000 0.005000 0.068945 1.000000 $ 12-Dec-2018 19:45:43.954 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.684781 28.350000 186.500000 $ 12-Dec-2018 19:45:44.405 Ascend MSC: OUT: SL $ 12-Dec-2018 19:45:44.125 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 786601120331180770000000000000000000000000000000000000.000000 -27124176563144160000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:44.125 Ascend SBE41 Message 20.30, 22.2449, 34.1892 20.299999 20.302218 0.008807 0.000000 0.000000 0.068400 1.000000 $ 12-Dec-2018 19:45:45.057 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.702327 28.350000 186.500000 $ 12-Dec-2018 19:45:45.406 Ascend MSC: RX: 0x1F7F,pH,01/31/2012 02:10:48,0,-1.00,-1.0000,-1.0000,256,147,0,23.23,56.59,11.744,4.620e-02,7.1234,0.000,-1.018042,0.004846,-1.-07 $ 12-Dec-2018 19:45:45.412 Ascend MSC: Data: 0x1F7F,pH,01/31/2012 02:10:48,0,-1.00,-1.0000,-1.0000,256,147,0,23.23,56.59,11.744,4.620e-02,7.1234,0.000,-1.018042,0.004846,-1.-07 $ 12-Dec-2018 19:45:45.169 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 -22811432489604242000000000000000000000000000000000000000.000000 786601120331180770000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:45.169 Ascend SBE41 Message 20.31, 22.2452, 34.1893 20.309999 20.303006 0.000865 -0.010000 -0.005000 0.067338 1.000000 $ 12-Dec-2018 19:45:46.162 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.309999 150.719002 28.350000 186.500000 $ 12-Dec-2018 19:45:46.405 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:45:46.507 Ascend MSC: OUT: SLP $ 12-Dec-2018 19:45:46.122 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 661531542198522960000000000000000000000000000000000000000.000000 -22811432489604242000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:46.122 Ascend SBE41 Message 20.30, 22.2459, 34.1888 20.299999 20.303083 -0.000561 0.010000 0.000000 0.065780 1.000000 $ 12-Dec-2018 19:45:47.159 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.787666 28.350000 186.500000 $ 12-Dec-2018 19:45:47.406 Ascend MSC: RX: ACK,SLP $ 12-Dec-2018 19:45:47.122 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 -19184414723757164000000000000000000000000000000000000000000.000000 661531542198522960000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:47.122 Ascend SBE41 Message 20.30, 22.2467, 34.1875 20.299999 20.302528 -0.000480 0.000000 0.005000 0.063729 1.000000 $ 12-Dec-2018 19:45:48.056 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.299999 150.798716 28.350000 186.500000 $ 12-Dec-2018 19:45:48.168 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010000 556348026988957750000000000000000000000000000000000000000000.000000 -19184414723757164000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:48.168 Ascend SBE41 Message 20.31, 22.2471, 34.1888 20.309999 20.302139 -0.000397 -0.010000 -0.005000 0.061174 1.000000 $ 12-Dec-2018 19:45:48.953 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.309999 150.797270 28.350000 186.500000 $ 12-Dec-2018 19:45:49.119 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009934 -16134092782679776000000000000000000000000000000000000000000000.000000 556348026988957750000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:49.119 Ascend SBE41 Message 20.31, 22.2479, 34.1885 20.309999 20.302529 -0.000458 0.000000 -0.005000 0.058217 1.000000 $ 12-Dec-2018 19:45:49.955 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.309999 150.809444 28.350000 186.500000 $ 12-Dec-2018 19:45:50.119 Ascend Vel PID Values 0.050000 0.439999 0.438534 0.438568 467888690697713530000000000000000000000000000000000000000000000.000000 -16134092782679776000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:50.119 Ascend SBE41 Message 19.87, 22.2476, 34.1893 19.870001 20.303135 -0.000456 0.439999 0.219999 0.055138 1.000000 $ 12-Dec-2018 19:45:50.955 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 19.870001 150.928386 28.350000 186.500000 $ 12-Dec-2018 19:45:51.414 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:45:51.515 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:45:52.022 Ascend Sending FLBB run command $ 12-Dec-2018 19:45:52.038 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:45:51.118 Ascend Vel PID Values 0.050000 0.800001 0.798801 0.360266 -13568772030233693000000000000000000000000000000000000000000000000.000000 467888690697713530000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:51.118 Ascend SBE41 Message 19.07, 22.2481, 34.1895 19.070000 20.302282 -0.000175 0.800001 0.620000 0.052467 1.000000 $ 12-Dec-2018 19:45:52.140 Ascend Vel PID Values 0.050000 0.059999 0.062460 -0.736341 393494388876777110000000000000000000000000000000000000000000000000.000000 -13568772030233693000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:52.140 Ascend SBE41 Message 19.01, 22.2487, 34.1892 19.010000 20.288592 0.001684 0.059999 0.430000 0.050720 1.000000 $ 12-Dec-2018 19:45:52.841 Ascend Radiometer Message SATFI40287,-0.0057,0.0005,-0.0069,-0.2316 $ 12-Dec-2018 19:45:53.257 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.010000 150.899984 28.350000 186.500000 $ 12-Dec-2018 19:45:53.369 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9633007 $ 12-Dec-2018 19:45:53.473 Ascend Starting ISUS sample $ 12-Dec-2018 19:45:53.576 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 12-Dec-2018 19:45:53.582 Ascend MSC: OUT: W $ 12-Dec-2018 19:45:53.934 Ascend MSC: OUT: W $ 12-Dec-2018 19:45:53.113 Ascend Optode Message %!4330,1532,263.284,22.717,29.126,29.056,36.101,7.045,536.4,465.7,103.3 $ 12-Dec-2018 19:45:53.115 Ascend Vel PID Values 0.050000 0.020000 0.020138 -0.042322 -11411337277426537000000000000000000000000000000000000000000000000000.000000 393494388876777110000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:53.115 Ascend SBE41 Message 18.99, 22.2489, 34.1878 18.990000 20.220817 0.010160 0.020000 0.040000 0.050119 1.000000 $ 12-Dec-2018 19:45:53.116 Ascend Optode Message # $ 12-Dec-2018 19:45:54.612 Ascend FLBB Message /99/99,99:99:99,695,2304,700,4130,533 $ 12-Dec-2018 19:45:54.723 Ascend MSC: RX: $ 12-Dec-2018 19:45:54.825 Ascend MSC: RX: $ 12-Dec-2018 19:45:54.149 Ascend Vel PID Values 0.050000 -0.010000 -0.009900 -0.030038 330928781045369590000000000000000000000000000000000000000000000000000.000000 -11411337277426537000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:54.149 Ascend SBE41 Message 19.00, 22.2492, 34.1895 19.000000 20.037859 0.032789 -0.010000 0.005000 0.050644 1.000000 $ 12-Dec-2018 19:45:55.274 Ascend MSC: RX: ACK $ 12-Dec-2018 19:45:55.278 Ascend MSC: Got ACK $ 12-Dec-2018 19:45:55.680 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 151.470259 28.350000 186.500000 $ 12-Dec-2018 19:45:55.791 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4156153 $ 12-Dec-2018 19:45:55.160 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009867 -9596934650315717700000000000000000000000000000000000000000000000000000.000000 330928781045369590000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:55.160 Ascend SBE41 Message 19.00, 22.2499, 34.1893 19.000000 19.731235 0.070636 0.000000 -0.005000 0.052279 1.000000 $ 12-Dec-2018 19:45:56.129 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009934 278311104859155820000000000000000000000000000000000000000000000000000000.000000 -9596934650315717700000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:56.129 Ascend SBE41 Message 19.01, 22.2496, 34.1891 19.010000 19.394636 0.112226 -0.010000 -0.005000 0.054852 1.000000 $ 12-Dec-2018 19:45:56.795 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.010000 151.849784 28.350000 186.500000 $ 12-Dec-2018 19:45:56.907 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1085867 $ 12-Dec-2018 19:45:57.012 Ascend MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 12-Dec-2018 19:45:57.114 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 -8071022040915517700000000000000000000000000000000000000000000000000000000.000000 278311104859155820000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:57.114 Ascend SBE41 Message 19.00, 22.2500, 34.1897 19.000000 19.150005 0.142556 0.010000 0.000000 0.057911 1.000000 $ 12-Dec-2018 19:45:57.674 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 152.027681 28.350000 186.500000 $ 12-Dec-2018 19:45:57.913 Ascend MSC: RX: NAK,CTD,EConvertErr: 0 $ 12-Dec-2018 19:45:58.016 Ascend MSC: EConvertErr: 0 $ 12-Dec-2018 19:45:58.222 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 152.228147 28.350000 186.500000 $ 12-Dec-2018 19:45:58.119 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 234059639186550030000000000000000000000000000000000000000000000000000000000.000000 -8071022040915517700000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:45:58.119 Ascend SBE41 Message 19.00, 22.2508, 34.1892 19.000000 19.035586 0.156814 0.000000 0.005000 0.060928 1.000000 $ 12-Dec-2018 19:45:59.150 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009934 -6787729536409951000000000000000000000000000000000000000000000000000000000000.000000 234059639186550030000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:45:59.150 Ascend SBE41 Message 18.99, 22.2513, 34.1895 18.990000 19.004480 0.160574 0.010000 0.005000 0.063586 1.000000 $ 12-Dec-2018 19:45:59.812 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.990000 152.235821 28.350000 186.500000 $ 12-Dec-2018 19:45:59.926 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0135898 $ 12-Dec-2018 19:46:00.029 Ascend MSC: OUT: W $ 12-Dec-2018 19:46:00.284 Ascend MSC: OUT: W $ 12-Dec-2018 19:46:00.131 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019901 196844156555888570000000000000000000000000000000000000000000000000000000000000.000000 -6787729536409951000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:00.131 Ascend SBE41 Message 19.00, 22.2516, 34.1894 19.000000 19.001621 0.159227 -0.010000 0.000000 0.065762 1.000000 $ 12-Dec-2018 19:46:00.734 Ascend MSC: RX: ACK $ 12-Dec-2018 19:46:00.738 Ascend MSC: Got ACK $ 12-Dec-2018 19:46:00.938 Ascend MSC: RX: ACK $ 12-Dec-2018 19:46:00.942 Ascend MSC: Got ACK $ 12-Dec-2018 19:46:01.141 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009901 -5708480540120768300000000000000000000000000000000000000000000000000000000000000.000000 196844156555888570000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:01.141 Ascend SBE41 Message 19.00, 22.2518, 34.1895 19.000000 19.002269 0.150737 0.000000 -0.005000 0.067268 1.000000 $ 12-Dec-2018 19:46:01.691 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 152.121656 28.350000 186.500000 $ 12-Dec-2018 19:46:01.804 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8731677 $ 12-Dec-2018 19:46:01.908 Ascend MSC: OUT: MODE,1 $ 12-Dec-2018 19:46:02.214 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 151.954636 28.350000 186.500000 $ 12-Dec-2018 19:46:02.106 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 165545935663502280000000000000000000000000000000000000000000000000000000000000000.000000 -5708480540120768300000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:02.106 Ascend SBE41 Message 19.00, 22.2526, 34.1894 19.000000 19.001119 0.128220 0.000000 0.000000 0.068467 1.000000 $ 12-Dec-2018 19:46:03.060 Ascend MSC: RX: ACK,MODE,1 $ 12-Dec-2018 19:46:03.158 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 -4800832134241566200000000000000000000000000000000000000000000000000000000000000000.000000 165545935663502280000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:03.158 Ascend SBE41 Message 19.01, 22.2523, 34.1899 19.010000 18.998852 0.090561 -0.010000 -0.005000 0.069157 1.000000 $ 12-Dec-2018 19:46:03.820 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.010000 151.970915 28.350000 186.500000 $ 12-Dec-2018 19:46:03.949 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1391175 $ 12-Dec-2018 19:46:03.955 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:46:04.155 Ascend Vel PID Values 0.050000 0.020000 0.019901 0.029868 139224131893005420000000000000000000000000000000000000000000000000000000000000000000.000000 -4800832134241566200000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:04.155 Ascend SBE41 Message 18.99, 22.2527, 34.1900 18.990000 18.997510 0.049098 0.020000 0.005000 0.069355 1.000000 $ 12-Dec-2018 19:46:04.707 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.990000 151.782684 28.350000 186.500000 $ 12-Dec-2018 19:46:05.158 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.990000 151.687041 28.350000 186.500000 $ 12-Dec-2018 19:46:05.955 Ascend MSC: OUT: TS $ 12-Dec-2018 19:46:05.103 Ascend Vel PID Values 0.050000 0.000000 0.000066 -0.019834 -4037499824897157400000000000000000000000000000000000000000000000000000000000000000000.000000 139224131893005420000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:05.103 Ascend SBE41 Message 18.99, 22.2537, 34.1895 18.990000 18.998064 0.018783 0.000000 0.010000 0.069065 1.000000 $ 12-Dec-2018 19:46:06.102 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010033 117087494922017560000000000000000000000000000000000000000000000000000000000000000000000.000000 -4037499824897157400000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:06.102 Ascend SBE41 Message 19.00, 22.2540, 34.1885 19.000000 18.999689 0.004438 -0.010000 -0.005000 0.068281 1.000000 $ 12-Dec-2018 19:46:06.755 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:46:07.060 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 151.669174 28.350000 186.500000 $ 12-Dec-2018 19:46:07.172 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2176430 $ 12-Dec-2018 19:46:07.170 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009934 -3395537352738509100000000000000000000000000000000000000000000000000000000000000000000000.000000 117087494922017560000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:07.170 Ascend SBE41 Message 19.00, 22.2544, 34.1896 19.000000 19.000585 0.000482 0.000000 -0.005000 0.066954 1.000000 $ 12-Dec-2018 19:46:07.828 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 151.906371 28.350000 186.500000 $ 12-Dec-2018 19:46:08.100 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 98470583229416768000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3395537352738509100000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:08.100 Ascend SBE41 Message 19.00, 22.2549, 34.1893 19.000000 18.999484 0.000264 0.000000 0.000000 0.065181 1.000000 $ 12-Dec-2018 19:46:08.732 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.000000 152.078889 28.350000 186.500000 $ 12-Dec-2018 19:46:09.098 Ascend Vel PID Values 0.050000 -0.020000 -0.019934 -0.019934 -2855646913653086400000000000000000000000000000000000000000000000000000000000000000000000000.000000 98470583229416768000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:09.098 Ascend SBE41 Message 19.02, 22.2557, 34.1891 19.020000 18.997199 0.000627 -0.020000 -0.010000 0.062928 1.000000 $ 12-Dec-2018 19:46:09.732 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.020000 152.069211 28.350000 186.500000 $ 12-Dec-2018 19:46:10.098 Ascend Vel PID Values 0.050000 0.530001 0.528171 0.548104 82813760495939502000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2855646913653086400000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:10.098 Ascend SBE41 Message 18.49, 22.2558, 34.1896 18.490000 18.996101 0.000620 0.530001 0.255000 0.060207 1.000000 $ 12-Dec-2018 19:46:10.732 Ascend PTH Message 796.116455 24.058333 54.451508 24.986704 $ 12-Dec-2018 19:46:10.934 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.490000 152.109779 27.550000 457.000000 $ 12-Dec-2018 19:46:11.097 Ascend Vel PID Values 0.050000 0.750000 0.749265 0.221094 -2401599054382245300000000000000000000000000000000000000000000000000000000000000000000000000000.000000 82813760495939502000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:11.097 Ascend SBE41 Message 17.74, 22.2557, 34.1902 17.740000 18.996034 0.000348 0.750000 0.640000 0.057130 1.000000 $ 12-Dec-2018 19:46:11.739 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 17.740000 152.100012 27.550000 457.000000 $ 12-Dec-2018 19:46:12.187 Ascend ERROR: Missed PH message 5 $ 12-Dec-2018 19:46:12.192 Ascend ERROR: Missed NO3 message 5 $ 12-Dec-2018 19:46:12.393 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:46:12.397 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:46:12.999 Ascend Sending FLBB run command $ 12-Dec-2018 19:46:13.016 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:46:12.096 Ascend Vel PID Values 0.050000 0.030001 0.032395 -0.716869 69646372577085117000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2401599054382245300000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:12.096 Ascend SBE41 Message 17.71, 22.2559, 34.1902 17.709999 18.982710 0.001830 0.030001 0.390000 0.054082 1.000000 $ 12-Dec-2018 19:46:13.478 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:46:13.118 Ascend Vel PID Values 0.050000 0.000000 0.000104 -0.032292 -2019744804735468400000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 69646372577085117000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:13.118 Ascend SBE41 Message 17.71, 22.2560, 34.1903 17.709999 18.910238 0.010857 0.000000 0.015000 0.051812 1.000000 $ 12-Dec-2018 19:46:14.025 Ascend Radiometer Message SATFI40287,-0.0060,0.0011,-0.0059,-0.2216 $ 12-Dec-2018 19:46:14.346 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.205467 27.550000 457.000000 $ 12-Dec-2018 19:46:14.458 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.2767820 $ 12-Dec-2018 19:46:14.139 Ascend Optode Message 4330,1532,263.497,22.713,29.118,29.049,36.096,7.047,536.4,465.5,103.4 $ 12-Dec-2018 19:46:14.139 Ascend Optode Message # $ 12-Dec-2018 19:46:14.140 Ascend Vel PID Values 0.050000 0.019999 0.019932 0.019828 58572599337328582000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2019744804735468400000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:14.140 Ascend SBE41 Message 17.69, 22.2571, 34.1898 17.690001 18.717489 0.034888 0.019999 0.009999 0.051142 1.000000 $ 12-Dec-2018 19:46:15.138 Ascend FLBB Message /99/99,99:99:99,695,2301,700,4130,533 $ 12-Dec-2018 19:46:15.137 Ascend Vel PID Values 0.050000 -0.019999 -0.019866 -0.039798 -1698605380782528800000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 58572599337328582000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:15.137 Ascend SBE41 Message 17.71, 22.2570, 34.1903 17.709999 18.403851 0.073782 -0.019999 0.000000 0.052404 1.000000 $ 12-Dec-2018 19:46:15.800 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.134344 27.550000 457.000000 $ 12-Dec-2018 19:46:15.913 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4478233 $ 12-Dec-2018 19:46:16.016 Ascend MSC: OUT: SL $ 12-Dec-2018 19:46:16.118 Ascend Vel PID Values 0.050000 0.009998 0.009899 0.029764 49259556042693339000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1698605380782528800000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:16.118 Ascend SBE41 Message 17.70, 22.2567, 34.1906 17.700001 18.071161 0.114802 0.009998 -0.005000 0.055169 1.000000 $ 12-Dec-2018 19:46:16.897 Ascend Error in I2CPortBase.Execute $ 12-Dec-2018 19:46:16.999 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.700001 152.134344 27.550000 457.000000 $ 12-Dec-2018 19:46:17.115 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1967650 $ 12-Dec-2018 19:46:17.421 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.700001 151.968770 27.550000 457.000000 $ 12-Dec-2018 19:46:18.122 Ascend MSC: RX: 0xC42C,A,01/31/2012 02:11:17,0,-1.00,-1.0000,-1.0000,229,147,1,65,23.28,56.65,11.576,5.238e-01,10516.00,2242.00,1198.92,14.48,-2FF3CC03C3D3CB23E10402C432F47204C3851FE58685F68663A6CC8722975F9781B78CA777D74F3715E6D3D691E656E62015F795DE05CFD5D0E5E46600C627F65B969B66E867385790B7F2084EC8A5D8F709398965897DD97C695EB92838DEE885781DA7B8E75106F22698864515FF25BED588955E25367515B4FE74EB14DE94D9A4D9C,6642.6 $ 12-Dec-2018 19:46:18.136 Ascend MSC: Data: 0xC42C,A,01/31/2012 02:11:17,0,-1.00,-1.0000,-1.0000,229,147,1,65,23.28,56.65,11.576,5.238e-01,10516.00,2242.00,1198.92,14.48,-2FF3CC03C3D3CB23E10402C432F47204C3851FE58685F68663A6CC8722975F9781B78CA777D74F3715E6D3D691E656E62015F795DE05CFD5D0E5E46600C627F65B969B66E867385790B7F2084EC8A5D8F709398965897DD97C695EB92838DEE885781DA7B8E75106F22698864515FF25BED588955E25367515B4FE74EB14DE94D9A4D9C,6642.6 $ 12-Dec-2018 19:46:17.283 Ascend Vel PID Values 0.050000 -0.009998 -0.009932 -0.019831 -1428527125238106800000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 49259556042693339000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:17.283 Ascend SBE41 Message 17.71, 22.2579, 34.1901 17.709999 17.838664 0.143301 -0.009998 0.000000 0.058579 1.000000 $ 12-Dec-2018 19:46:18.091 Ascend Vel PID Values 0.050000 0.009998 0.009932 0.019864 41427286631905096000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1428527125238106800000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:18.091 Ascend SBE41 Message 17.70, 22.2585, 34.1899 17.700001 17.734354 0.156098 0.009998 0.000000 0.061971 1.000000 $ 12-Dec-2018 19:46:19.246 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.700001 151.844576 27.550000 457.000000 $ 12-Dec-2018 19:46:19.358 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2364829 $ 12-Dec-2018 19:46:19.363 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:46:19.465 Ascend Starting pH sample $ 12-Dec-2018 19:46:19.566 Ascend MSC: OUT: W $ 12-Dec-2018 19:46:20.016 Ascend MSC: OUT: W $ 12-Dec-2018 19:46:19.089 Ascend Vel PID Values 0.050000 -0.009998 -0.009932 -0.019864 -1201391312325247700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 41427286631905096000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:19.089 Ascend SBE41 Message 17.71, 22.2585, 34.1901 17.709999 17.706464 0.159556 -0.009998 0.000000 0.064987 1.000000 $ 12-Dec-2018 19:46:20.467 Ascend MSC: RX: ACK $ 12-Dec-2018 19:46:20.471 Ascend MSC: Got ACK $ 12-Dec-2018 19:46:20.118 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009899 34840348057432185000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1201391312325247700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:20.118 Ascend SBE41 Message 17.71, 22.2586, 34.1902 17.709999 17.703165 0.158307 0.000000 -0.004999 0.067524 1.000000 $ 12-Dec-2018 19:46:21.020 Ascend MSC: RX: ACK $ 12-Dec-2018 19:46:21.024 Ascend MSC: Got ACK $ 12-Dec-2018 19:46:21.427 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.256720 27.550000 457.000000 $ 12-Dec-2018 19:46:21.538 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1753167 $ 12-Dec-2018 19:46:21.642 Ascend MSC: OUT: MODE,2 $ 12-Dec-2018 19:46:21.123 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009934 -1010370093665533300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 34840348057432185000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:21.123 Ascend SBE41 Message 17.72, 22.2592, 34.1900 17.719999 17.703990 0.149212 -0.010000 -0.005000 0.069570 1.000000 $ 12-Dec-2018 19:46:22.299 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.719999 152.693272 27.550000 457.000000 $ 12-Dec-2018 19:46:22.545 Ascend MSC: RX: ACK,MODE,2 $ 12-Dec-2018 19:46:22.117 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 29300732716300466000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1010370093665533300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:22.117 Ascend SBE41 Message 17.71, 22.2594, 34.1902 17.709999 17.705030 0.125215 0.010000 0.000000 0.071125 1.000000 $ 12-Dec-2018 19:46:23.197 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.917407 27.550000 457.000000 $ 12-Dec-2018 19:46:23.084 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 -849721248772713510000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 29300732716300466000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:23.084 Ascend SBE41 Message 17.71, 22.2598, 34.1902 17.709999 17.706351 0.086246 0.000000 0.005000 0.072178 1.000000 $ 12-Dec-2018 19:46:24.096 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.890876 27.550000 457.000000 $ 12-Dec-2018 19:46:24.545 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:46:24.082 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 24641916214408692000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -849721248772713510000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:24.082 Ascend SBE41 Message 17.71, 22.2600, 34.1902 17.709999 17.708569 0.044828 0.000000 0.000000 0.072745 1.000000 $ 12-Dec-2018 19:46:25.200 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.913876 27.550000 457.000000 $ 12-Dec-2018 19:46:25.083 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 -714615570217852060000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 24641916214408692000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:25.083 Ascend SBE41 Message 17.72, 22.2613, 34.1897 17.719999 17.711118 0.015767 -0.010000 -0.005000 0.072798 1.000000 $ 12-Dec-2018 19:46:26.096 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.719999 152.914263 27.550000 457.000000 $ 12-Dec-2018 19:46:26.545 Ascend MSC: OUT: TS $ 12-Dec-2018 19:46:26.083 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 20723851536317709000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -714615570217852060000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:26.083 Ascend SBE41 Message 17.71, 22.2607, 34.1905 17.709999 17.712548 0.002695 0.010000 0.000000 0.072372 1.000000 $ 12-Dec-2018 19:46:27.200 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.924500 27.550000 457.000000 $ 12-Dec-2018 19:46:27.546 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:46:27.080 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019868 -600991694553213530000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 20723851536317709000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:27.080 Ascend SBE41 Message 17.72, 22.2614, 34.1901 17.719999 17.712470 -0.000744 -0.010000 0.000000 0.071462 1.000000 $ 12-Dec-2018 19:46:28.199 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.719999 152.915508 27.550000 457.000000 $ 12-Dec-2018 19:46:28.080 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019868 17428759142043192000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -600991694553213530000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:28.080 Ascend SBE41 Message 17.71, 22.2616, 34.1902 17.709999 17.712168 -0.001114 0.010000 0.000000 0.070056 1.000000 $ 12-Dec-2018 19:46:29.100 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 152.921185 27.550000 457.000000 $ 12-Dec-2018 19:46:29.080 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019868 -505434015119252590000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 17428759142043192000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:29.080 Ascend SBE41 Message 17.72, 22.2616, 34.1905 17.719999 17.712781 -0.001088 -0.010000 0.000000 0.068170 1.000000 $ 12-Dec-2018 19:46:30.098 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.719999 152.946584 27.550000 457.000000 $ 12-Dec-2018 19:46:30.077 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019868 14657586438458326000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -505434015119252590000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:30.077 Ascend SBE41 Message 17.71, 22.2618, 34.1907 17.709999 17.713929 -0.001101 0.010000 0.000000 0.065791 1.000000 $ 12-Dec-2018 19:46:31.097 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.709999 153.064385 27.550000 457.000000 $ 12-Dec-2018 19:46:31.077 Ascend Vel PID Values 0.050000 0.359999 0.358834 0.348900 -425070006715291450000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 14657586438458326000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:31.077 Ascend SBE41 Message 17.35, 22.2627, 34.1903 17.350000 17.714712 -0.001034 0.359999 0.184999 0.062923 1.000000 $ 12-Dec-2018 19:46:32.098 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 17.350000 153.072961 27.550000 457.000000 $ 12-Dec-2018 19:46:32.076 Ascend Vel PID Values 0.050000 0.860001 0.858335 0.499501 12327030194743452000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -425070006715291450000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:32.076 Ascend SBE41 Message 16.49, 22.2626, 34.1907 16.490000 17.713859 -0.000654 0.860001 0.610000 0.059620 1.000000 $ 12-Dec-2018 19:46:33.098 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.490000 153.183125 27.550000 457.000000 $ 12-Dec-2018 19:46:33.075 Ascend Vel PID Values 0.050000 0.090000 0.092560 -0.765775 -357483875647560080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 12327030194743452000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:33.075 Ascend SBE41 Message 16.40, 22.2635, 34.1906 16.400000 17.700954 0.001256 0.090000 0.475000 0.056142 1.000000 $ 12-Dec-2018 19:46:34.099 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.186828 27.550000 457.000000 $ 12-Dec-2018 19:46:34.073 Ascend Vel PID Values 0.050000 0.000000 0.000304 -0.092256 10367032393779242000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -357483875647560080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:34.073 Ascend SBE41 Message 16.40, 22.2637, 34.1907 16.400000 17.637127 0.009323 0.000000 0.045000 0.053126 1.000000 $ 12-Dec-2018 19:46:35.107 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.224714 27.550000 457.000000 $ 12-Dec-2018 19:46:35.073 Ascend Vel PID Values 0.050000 0.000000 0.000001 -0.000303 -300643939419598030000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 10367032393779242000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:35.073 Ascend SBE41 Message 16.40, 22.2641, 34.1907 16.400000 17.461342 0.031046 0.000000 0.000000 0.051481 1.000000 $ 12-Dec-2018 19:46:36.117 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.252475 27.550000 457.000000 $ 12-Dec-2018 19:46:36.072 Ascend Vel PID Values 0.050000 0.000000 -0.000000 -0.000001 8718674243168342500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -300643939419598030000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:36.072 Ascend SBE41 Message 16.40, 22.2641, 34.1909 16.400000 17.158706 0.068431 0.000000 0.000000 0.051820 1.000000 $ 12-Dec-2018 19:46:37.097 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.316095 27.550000 457.000000 $ 12-Dec-2018 19:46:37.070 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009967 -252841553051881920000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 8718674243168342500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:37.070 Ascend SBE41 Message 16.39, 22.2648, 34.1908 16.389999 16.817146 0.110757 0.010000 0.005000 0.053936 1.000000 $ 12-Dec-2018 19:46:38.096 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.389999 153.299503 27.550000 457.000000 $ 12-Dec-2018 19:46:38.546 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:46:38.069 Ascend Vel PID Values 0.050000 -0.020000 -0.019901 -0.029868 7332405038504575300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -252841553051881920000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:38.069 Ascend SBE41 Message 16.41, 22.2651, 34.1910 16.410000 16.562386 0.142432 -0.020000 -0.005000 0.056989 1.000000 $ 12-Dec-2018 19:46:39.199 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 153.433658 27.550000 457.000000 $ 12-Dec-2018 19:46:39.068 Ascend Vel PID Values 0.050000 0.010000 0.009901 0.029801 -212639746116632680000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 7332405038504575300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:39.068 Ascend SBE41 Message 16.40, 22.2656, 34.1910 16.400000 16.440029 0.157694 0.010000 -0.005000 0.060136 1.000000 $ 12-Dec-2018 19:46:40.096 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.421961 27.550000 457.000000 $ 12-Dec-2018 19:46:40.546 Ascend MSC: OUT: SL $ 12-Dec-2018 19:46:40.067 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009867 6166552637382347800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -212639746116632680000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:40.067 Ascend SBE41 Message 16.40, 22.2661, 34.1908 16.400000 16.404570 0.161994 0.000000 0.005000 0.062947 1.000000 $ 12-Dec-2018 19:46:41.201 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.437749 27.550000 457.000000 $ 12-Dec-2018 19:46:41.546 Ascend MSC: RX: 0x7101,pH,01/31/2012 02:11:44,0,-1.00,-1.0000,-1.0000,257,147,0,23.30,56.65,11.744,4.640e-02,7.1234,0.000,-1.012412,0.005614,-1. $ 12-Dec-2018 19:46:41.651 Ascend MSC: Data: 0x7101,pH,01/31/2012 02:11:44,0,-1.00,-1.0000,-1.0000,257,147,0,23.30,56.65,11.744,4.640e-02,7.1234,0.000,-1.012412,0.005614,-1. $ 12-Dec-2018 19:46:41.080 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 -178830026484088100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 6166552637382347800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:41.080 Ascend SBE41 Message 16.40, 22.2661, 34.1911 16.400000 16.399132 0.161065 0.000000 0.000000 0.065282 1.000000 $ 12-Dec-2018 19:46:42.308 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 153.447010 27.550000 457.000000 $ 12-Dec-2018 19:46:42.545 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:46:42.647 Ascend MSC: OUT: SLP $ 12-Dec-2018 19:46:42.105 Ascend Vel PID Values 0.050000 -0.020000 -0.019934 -0.019934 5186070768038555000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -178830026484088100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:42.105 Ascend SBE41 Message 16.42, 22.2676, 34.1904 16.420000 16.399418 0.153109 -0.020000 -0.010000 0.067135 1.000000 $ 12-Dec-2018 19:46:43.100 Ascend Vel PID Values 0.050000 0.010000 0.009901 0.029834 -150396052273118090000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 5186070768038555000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:43.100 Ascend SBE41 Message 16.41, 22.2677, 34.1907 16.410000 16.400642 0.131185 0.010000 -0.005000 0.068487 1.000000 $ 12-Dec-2018 19:46:43.450 Ascend MSC: RX: ACK,SLP $ 12-Dec-2018 19:46:43.754 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 153.438047 27.550000 457.000000 $ 12-Dec-2018 19:46:43.867 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3223661 $ 12-Dec-2018 19:46:44.173 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 153.452329 27.550000 457.000000 $ 12-Dec-2018 19:46:44.064 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009867 4361485515920424600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -150396052273118090000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:44.064 Ascend SBE41 Message 16.41, 22.2680, 34.1909 16.410000 16.401741 0.093602 0.000000 0.005000 0.069359 1.000000 $ 12-Dec-2018 19:46:45.110 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 -126483079961692310000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 4361485515920424600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:45.110 Ascend SBE41 Message 16.41, 22.2686, 34.1904 16.410000 16.403239 0.051173 0.000000 0.000000 0.069739 1.000000 $ 12-Dec-2018 19:46:45.779 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 153.450057 27.550000 457.000000 $ 12-Dec-2018 19:46:45.891 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0180067 $ 12-Dec-2018 19:46:46.196 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 153.317913 27.550000 457.000000 $ 12-Dec-2018 19:46:46.061 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000000 3668009318889077200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -126483079961692310000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:46.061 Ascend SBE41 Message 16.41, 22.2693, 34.1904 16.410000 16.406069 0.019324 0.000000 0.000000 0.069628 1.000000 $ 12-Dec-2018 19:46:47.134 Ascend Vel PID Values 0.050000 0.000000 -0.000000 -0.000000 -106372270247783240000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 3668009318889077200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:47.134 Ascend SBE41 Message 16.41, 22.2701, 34.1902 16.410000 16.409231 0.003806 0.000000 0.000000 0.068974 1.000000 $ 12-Dec-2018 19:46:47.801 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 153.169259 27.550000 457.000000 $ 12-Dec-2018 19:46:47.916 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0202617 $ 12-Dec-2018 19:46:48.221 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 152.919330 27.550000 457.000000 $ 12-Dec-2018 19:46:48.060 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 3084795837185714200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -106372270247783240000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:48.060 Ascend SBE41 Message 16.42, 22.2700, 34.1904 16.420000 16.410837 -0.000776 -0.010000 -0.005000 0.067871 1.000000 $ 12-Dec-2018 19:46:49.059 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 -89459079278385718000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 3084795837185714200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:49.059 Ascend SBE41 Message 16.41, 22.2704, 34.1906 16.410000 16.410788 -0.001442 0.010000 0.000000 0.066291 1.000000 $ 12-Dec-2018 19:46:49.833 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 152.740724 27.550000 457.000000 $ 12-Dec-2018 19:46:49.945 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0240166 $ 12-Dec-2018 19:46:50.251 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.410000 152.609304 27.550000 457.000000 $ 12-Dec-2018 19:46:50.057 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 2594313299073186000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -89459079278385718000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:50.057 Ascend SBE41 Message 16.41, 22.2706, 34.1907 16.410000 16.410534 -0.001375 0.000000 0.005000 0.064228 1.000000 $ 12-Dec-2018 19:46:51.057 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009934 -75235085673122388000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 2594313299073186000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:51.057 Ascend SBE41 Message 16.40, 22.2706, 34.1911 16.400000 16.411099 -0.001294 0.010000 0.005000 0.061676 1.000000 $ 12-Dec-2018 19:46:51.854 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.400000 152.396232 27.550000 457.000000 $ 12-Dec-2018 19:46:51.967 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0167396 $ 12-Dec-2018 19:46:52.071 Ascend Vel PID Values 0.050000 0.059999 0.059833 0.049866 2181817484520549000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -75235085673122388000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:52.071 Ascend SBE41 Message 16.34, 22.2715, 34.1906 16.340000 16.412188 -0.001292 0.059999 0.035000 0.058681 1.000000 $ 12-Dec-2018 19:46:52.625 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.340000 152.110629 27.550000 457.000000 $ 12-Dec-2018 19:46:53.055 Ascend Vel PID Values 0.050000 0.930000 0.927105 0.867272 -63272707051095922000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 2181817484520549000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:53.055 Ascend SBE41 Message 15.41, 22.2718, 34.1910 15.410000 16.412297 -0.001120 0.930000 0.495000 0.055481 1.000000 $ 12-Dec-2018 19:46:53.624 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 15.410000 152.007155 27.550000 457.000000 $ 12-Dec-2018 19:46:54.079 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:46:54.083 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:46:54.685 Ascend Sending FLBB run command $ 12-Dec-2018 19:46:54.804 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:46:54.054 Ascend Vel PID Values 0.050000 0.380000 0.381826 -0.545279 1834908504481781600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -63272707051095922000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:54.054 Ascend SBE41 Message 15.03, 22.2724, 34.1911 15.030000 16.406205 -0.000017 0.380000 0.655000 0.052575 1.000000 $ 12-Dec-2018 19:46:55.263 Ascend Radiometer Message SATFI40287,-0.0058,0.0015,-0.0054,-0.2163 $ 12-Dec-2018 19:46:55.149 Ascend Vel PID Values 0.050000 0.000000 0.001268 -0.380558 -53212346629971672000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1834908504481781600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:55.149 Ascend SBE41 Message 15.03, 22.2726, 34.1912 15.030000 16.369092 0.004961 0.000000 0.190000 0.050555 1.000000 $ 12-Dec-2018 19:46:55.933 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.030000 151.964717 27.550000 457.000000 $ 12-Dec-2018 19:46:56.047 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9759923 $ 12-Dec-2018 19:46:56.053 Ascend Starting ISUS sample $ 12-Dec-2018 19:46:56.253 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 12-Dec-2018 19:46:56.356 Ascend MSC: OUT: W $ 12-Dec-2018 19:46:56.611 Ascend MSC: OUT: W $ 12-Dec-2018 19:46:55.776 Ascend Optode Message 4330,1532,263.455,22.719,29.118,29.048,36.097,7.048,536.3,465.2,103.3 $ 12-Dec-2018 19:46:55.779 Ascend Optode Message # $ 12-Dec-2018 19:46:56.844 Ascend FLBB Message /99/99,99:99:99,695,2290,700,4130,533 $ 12-Dec-2018 19:46:56.150 Ascend Vel PID Values 0.050000 0.000000 0.000002 -0.001266 1543158052269178500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -53212346629971672000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:56.150 Ascend SBE41 Message 15.03, 22.2729, 34.1914 15.030000 16.242001 0.020872 0.000000 0.000000 0.049905 1.000000 $ 12-Dec-2018 19:46:57.405 Ascend MSC: RX: $ 12-Dec-2018 19:46:57.506 Ascend MSC: RX: $ 12-Dec-2018 19:46:57.051 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000002 -44751583515806180000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1543158052269178500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:57.051 Ascend SBE41 Message 15.03, 22.2742, 34.1902 15.030000 15.975791 0.053781 0.000000 0.000000 0.050765 1.000000 $ 12-Dec-2018 19:46:57.958 Ascend MSC: RX: ACK $ 12-Dec-2018 19:46:57.962 Ascend MSC: Got ACK $ 12-Dec-2018 19:46:58.365 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.030000 151.787564 27.550000 457.000000 $ 12-Dec-2018 19:46:58.478 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4253352 $ 12-Dec-2018 19:46:58.061 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 1297795921958379200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -44751583515806180000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:46:58.061 Ascend SBE41 Message 15.04, 22.2740, 34.1910 15.040000 15.616557 0.098178 -0.010000 -0.005000 0.053029 1.000000 $ 12-Dec-2018 19:46:59.135 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.477978 27.550000 457.000000 $ 12-Dec-2018 19:46:59.485 Ascend MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 12-Dec-2018 19:46:59.048 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 -37636081736792997000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1297795921958379200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:46:59.048 Ascend SBE41 Message 15.03, 22.2744, 34.1910 15.030000 15.297149 0.137770 0.010000 0.000000 0.056174 1.000000 $ 12-Dec-2018 19:47:00.151 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.030000 151.404917 27.550000 457.000000 $ 12-Dec-2018 19:47:00.485 Ascend MSC: RX: NAK,CTD,EConvertErr: 0 $ 12-Dec-2018 19:47:00.589 Ascend MSC: EConvertErr: 0 $ 12-Dec-2018 19:47:00.048 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019868 1091446370366996900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -37636081736792997000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:00.048 Ascend SBE41 Message 15.04, 22.2751, 34.1909 15.040000 15.111909 0.160848 -0.010000 0.000000 0.059549 1.000000 $ 12-Dec-2018 19:47:01.242 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.375890 27.550000 457.000000 $ 12-Dec-2018 19:47:01.047 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009901 -31651944740642907000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1091446370366996900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:01.047 Ascend SBE41 Message 15.04, 22.2747, 34.1915 15.040000 15.045692 0.169080 0.000000 -0.005000 0.062675 1.000000 $ 12-Dec-2018 19:47:02.039 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.367053 27.550000 457.000000 $ 12-Dec-2018 19:47:02.484 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:02.740 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:02.150 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 917906397478644300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -31651944740642907000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:02.150 Ascend SBE41 Message 15.04, 22.2750, 34.1915 15.040000 15.033670 0.169820 0.000000 0.000000 0.065326 1.000000 $ 12-Dec-2018 19:47:03.206 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:03.210 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:03.410 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:03.511 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:03.091 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009967 -26619285526880682000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 917906397478644300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:03.091 Ascend SBE41 Message 15.03, 22.2765, 34.1905 15.030000 15.034188 0.165145 0.010000 0.005000 0.067487 1.000000 $ 12-Dec-2018 19:47:04.166 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.030000 151.386283 27.550000 457.000000 $ 12-Dec-2018 19:47:04.279 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7947622 $ 12-Dec-2018 19:47:04.382 Ascend MSC: OUT: MODE,1 $ 12-Dec-2018 19:47:04.043 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019901 771959280279539770000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -26619285526880682000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:04.043 Ascend SBE41 Message 15.04, 22.2764, 34.1912 15.040000 15.035788 0.149195 -0.010000 0.000000 0.069143 1.000000 $ 12-Dec-2018 19:47:05.041 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.318125 27.550000 457.000000 $ 12-Dec-2018 19:47:05.284 Ascend MSC: RX: ACK,MODE,1 $ 12-Dec-2018 19:47:05.155 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009901 -22386819128106655000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 771959280279539770000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:05.155 Ascend SBE41 Message 15.04, 22.2765, 34.1912 15.040000 15.037189 0.116070 0.000000 -0.005000 0.070255 1.000000 $ 12-Dec-2018 19:47:05.940 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.323237 27.550000 457.000000 $ 12-Dec-2018 19:47:06.050 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 649217754715093070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -22386819128106655000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:06.050 Ascend SBE41 Message 15.04, 22.2767, 34.1915 15.040000 15.037831 0.071555 0.000000 0.000000 0.070885 1.000000 $ 12-Dec-2018 19:47:06.838 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.313290 27.550000 457.000000 $ 12-Dec-2018 19:47:07.285 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:47:07.041 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 -18827314886737697000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 649217754715093070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:07.041 Ascend SBE41 Message 15.05, 22.2776, 34.1912 15.050000 15.037500 0.032099 -0.010000 -0.005000 0.071017 1.000000 $ 12-Dec-2018 19:47:07.954 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.050000 151.300967 27.550000 457.000000 $ 12-Dec-2018 19:47:08.064 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 545992131715393270000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -18827314886737697000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:08.064 Ascend SBE41 Message 15.04, 22.2775, 34.1917 15.040000 15.037198 0.009235 0.010000 0.000000 0.070644 1.000000 $ 12-Dec-2018 19:47:08.838 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.303783 27.550000 457.000000 $ 12-Dec-2018 19:47:09.285 Ascend MSC: OUT: TS $ 12-Dec-2018 19:47:09.038 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 -15833771819746404000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 545992131715393270000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:09.038 Ascend SBE41 Message 15.04, 22.2787, 34.1910 15.040000 15.038063 0.000942 0.000000 0.005000 0.069771 1.000000 $ 12-Dec-2018 19:47:09.739 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:47:10.043 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.040000 151.313238 27.550000 457.000000 $ 12-Dec-2018 19:47:10.037 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010000 459179382772645730000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -15833771819746404000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:10.037 Ascend SBE41 Message 15.05, 22.2786, 34.1911 15.050000 15.040000 -0.000783 -0.010000 -0.005000 0.068384 1.000000 $ 12-Dec-2018 19:47:10.839 Ascend PTH Message 798.161865 24.058333 54.474396 24.986704 $ 12-Dec-2018 19:47:11.042 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.050000 151.301458 27.475000 324.000000 $ 12-Dec-2018 19:47:11.041 Ascend Vel PID Values 0.050000 0.040000 0.039834 0.049801 -13316202100406725000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 459179382772645730000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:11.041 Ascend SBE41 Message 15.01, 22.2793, 34.1915 15.010000 15.041965 -0.000962 0.040000 0.015000 0.066483 1.000000 $ 12-Dec-2018 19:47:11.838 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.010000 151.305214 27.475000 324.000000 $ 12-Dec-2018 19:47:12.036 Ascend Vel PID Values 0.050000 0.850000 0.847305 0.807471 386169860911794980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -13316202100406725000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:12.036 Ascend SBE41 Message 14.16, 22.2799, 34.1907 14.160000 15.042952 -0.000886 0.850000 0.445000 0.064081 1.000000 $ 12-Dec-2018 19:47:12.839 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.160000 151.424430 27.475000 324.000000 $ 12-Dec-2018 19:47:13.033 Ascend Vel PID Values 0.050000 0.500000 0.501160 -0.346144 -11198925966442054000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 386169860911794980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:13.033 Ascend SBE41 Message 13.66, 22.2801, 34.1917 13.660000 15.039826 -0.000327 0.500000 0.675000 0.061238 1.000000 $ 12-Dec-2018 19:47:13.842 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 13.660000 151.448615 27.475000 324.000000 $ 12-Dec-2018 19:47:14.295 Ascend ERROR: Missed PH message 6 $ 12-Dec-2018 19:47:14.299 Ascend ERROR: Missed NO3 message 6 $ 12-Dec-2018 19:47:14.500 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:47:14.504 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:47:15.106 Ascend Sending FLBB run command $ 12-Dec-2018 19:47:15.125 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:47:14.033 Ascend Vel PID Values 0.050000 -0.010000 -0.008301 -0.509461 324768853026819560000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -11198925966442054000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:14.033 Ascend SBE41 Message 13.67, 22.2803, 34.1918 13.670000 15.011190 0.003292 -0.010000 0.245000 0.058244 1.000000 $ 12-Dec-2018 19:47:15.032 Ascend Vel PID Values 0.050000 0.000000 -0.000030 0.008271 -9418296737777767900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 324768853026819560000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:15.032 Ascend SBE41 Message 13.67, 22.2807, 34.1919 13.670000 14.899343 0.017078 0.000000 -0.005000 0.055842 1.000000 $ 12-Dec-2018 19:47:16.034 Ascend Radiometer Message SATFI40287,-0.0063,0.0006,-0.0058,-0.2356 $ 12-Dec-2018 19:47:16.033 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000030 273130605395555270000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -9418296737777767900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:16.033 Ascend SBE41 Message 13.67, 22.2808, 34.1921 13.670000 14.648362 0.048072 0.000000 0.000000 0.055041 1.000000 $ 12-Dec-2018 19:47:16.611 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.507348 27.475000 324.000000 $ 12-Dec-2018 19:47:16.725 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4391467 $ 12-Dec-2018 19:47:16.828 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:47:16.198 Ascend Optode Message 4330,1532,263.357,22.725,29.119,29.049,36.157,7.108,536.2,464.9,103.0 $ 12-Dec-2018 19:47:16.201 Ascend Optode Message # $ 12-Dec-2018 19:47:17.060 Ascend FLBB Message /99/99,99:99:99,695,2318,700,4130,533 $ 12-Dec-2018 19:47:17.044 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000000 -7920787556471102500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 273130605395555270000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:17.044 Ascend SBE41 Message 13.67, 22.2815, 34.1919 13.670000 14.292568 0.092181 0.000000 0.000000 0.056387 1.000000 $ 12-Dec-2018 19:47:17.824 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.448764 27.475000 324.000000 $ 12-Dec-2018 19:47:17.935 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2052153 $ 12-Dec-2018 19:47:18.040 Ascend Vel PID Values 0.050000 0.000000 0.000000 0.000000 229702839137661960000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -7920787556471102500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:18.040 Ascend SBE41 Message 13.67, 22.2820, 34.1893 13.670000 13.962178 0.133299 0.000000 0.000000 0.059450 1.000000 $ 12-Dec-2018 19:47:18.596 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.459709 27.475000 324.000000 $ 12-Dec-2018 19:47:18.943 Ascend MSC: OUT: SL $ 12-Dec-2018 19:47:19.046 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000000 -6661382334992196700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 229702839137661960000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:19.046 Ascend SBE41 Message 13.67, 22.2827, 34.1917 13.670000 13.762051 0.158326 0.000000 0.000000 0.063231 1.000000 $ 12-Dec-2018 19:47:19.830 Ascend Error in I2CPortBase.Execute $ 12-Dec-2018 19:47:19.932 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.459709 27.475000 324.000000 $ 12-Dec-2018 19:47:20.043 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1007252 $ 12-Dec-2018 19:47:20.350 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.459903 27.475000 324.000000 $ 12-Dec-2018 19:47:21.051 Ascend MSC: RX: 0xD8C6,A,01/31/2012 02:12:21,0,-1.00,-1.0000,-1.0000,230,147,1,65,23.38,56.48,11.576,5.238e-01,10506.00,2237.00,1204.40,13.35,-275E177FF7891775D74DE71296D2E6900653E61CD5F625DC55D0A5D135E115FE5624F65B6699C6E45735279047F1484C18A3F8F3D936C963897C3978C95B592768DE3885381D37B6174E86EFE697864455FDB5BDD588755B3533B51484FC44EA34DF64D894D88,6645.4 $ 12-Dec-2018 19:47:21.159 Ascend MSC: Data: 0xD8C6,A,01/31/2012 02:12:21,0,-1.00,-1.0000,-1.0000,230,147,1,65,23.38,56.48,11.576,5.238e-01,10506.00,2237.00,1204.40,13.35,-275E177FF7891775D74DE71296D2E6900653E61CD5F625DC55D0A5D135E115FE5624F65B6699C6E45735279047F1484C18A3F8F3D936C963897C3978C95B592768DE3885381D37B6174E86EFE697864455FDB5BDD588755B3533B51484FC44EA34DF64D894D88,6645.4 $ 12-Dec-2018 19:47:20.182 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000000 193180087714773710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -6661382334992196700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:20.182 Ascend SBE41 Message 13.67, 22.2827, 34.1918 13.670000 13.686712 0.167796 0.000000 0.000000 0.066902 1.000000 $ 12-Dec-2018 19:47:21.027 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000000 -5602222543728437500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 193180087714773710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:21.027 Ascend SBE41 Message 13.67, 22.2838, 34.1913 13.670000 13.671184 0.169339 0.000000 0.000000 0.070158 1.000000 $ 12-Dec-2018 19:47:22.180 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.439019 27.475000 324.000000 $ 12-Dec-2018 19:47:22.298 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2474888 $ 12-Dec-2018 19:47:22.400 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:47:22.404 Ascend Starting pH sample $ 12-Dec-2018 19:47:22.506 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:22.956 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:22.025 Ascend Vel PID Values 0.050000 0.000000 -0.000000 -0.000000 162464453768124690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -5602222543728437500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:22.025 Ascend SBE41 Message 13.67, 22.2832, 34.1908 13.670000 13.669978 0.165929 0.000000 0.000000 0.072897 1.000000 $ 12-Dec-2018 19:47:23.316 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:23.417 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:23.058 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009967 -4711469159275616700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 162464453768124690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:23.058 Ascend SBE41 Message 13.68, 22.2835, 34.1920 13.680000 13.670000 0.152059 -0.010000 -0.005000 0.075112 1.000000 $ 12-Dec-2018 19:47:23.969 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:23.974 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:24.377 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.680000 151.349321 27.475000 324.000000 $ 12-Dec-2018 19:47:24.488 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1851726 $ 12-Dec-2018 19:47:24.592 Ascend MSC: OUT: MODE,2 $ 12-Dec-2018 19:47:24.072 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 136632605618992900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -4711469159275616700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:24.072 Ascend SBE41 Message 13.67, 22.2843, 34.1920 13.670000 13.670030 0.120986 0.010000 0.000000 0.076818 1.000000 $ 12-Dec-2018 19:47:25.251 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 151.049495 27.475000 324.000000 $ 12-Dec-2018 19:47:25.494 Ascend MSC: RX: ACK,MODE,2 $ 12-Dec-2018 19:47:25.069 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009901 -3962345562950794200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 136632605618992900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:25.069 Ascend SBE41 Message 13.67, 22.2846, 34.1919 13.670000 13.670282 0.076942 0.000000 0.005000 0.077988 1.000000 $ 12-Dec-2018 19:47:26.152 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 150.916785 27.475000 324.000000 $ 12-Dec-2018 19:47:26.021 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 114908021325573040000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3962345562950794200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:26.021 Ascend SBE41 Message 13.67, 22.2848, 34.1922 13.670000 13.671070 0.035989 0.000000 0.000000 0.078662 1.000000 $ 12-Dec-2018 19:47:27.050 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 150.942460 27.475000 324.000000 $ 12-Dec-2018 19:47:27.493 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:47:27.020 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000000 -3332332618441618100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 114908021325573040000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:27.020 Ascend SBE41 Message 13.67, 22.2855, 34.1921 13.670000 13.672218 0.011105 0.000000 0.000000 0.078781 1.000000 $ 12-Dec-2018 19:47:28.152 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 150.941633 27.475000 324.000000 $ 12-Dec-2018 19:47:28.018 Ascend Vel PID Values 0.050000 0.000000 -0.000000 -0.000000 96637645934806924000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3332332618441618100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:28.018 Ascend SBE41 Message 13.67, 22.2858, 34.1919 13.670000 13.672802 0.001719 0.000000 0.000000 0.078401 1.000000 $ 12-Dec-2018 19:47:29.048 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 150.927104 27.475000 324.000000 $ 12-Dec-2018 19:47:29.493 Ascend MSC: OUT: TS $ 12-Dec-2018 19:47:29.018 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000000 -2802491732109400700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 96637645934806924000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:29.018 Ascend SBE41 Message 13.67, 22.2867, 34.1918 13.670000 13.672218 -0.000128 0.000000 0.000000 0.077509 1.000000 $ 12-Dec-2018 19:47:30.150 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.670000 150.938451 27.475000 324.000000 $ 12-Dec-2018 19:47:30.494 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:47:30.016 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009967 81272260231172618000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2802491732109400700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:30.016 Ascend SBE41 Message 13.66, 22.2868, 34.1914 13.660000 13.671070 -0.000135 0.010000 0.005000 0.076108 1.000000 $ 12-Dec-2018 19:47:31.150 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.660000 150.946639 27.475000 324.000000 $ 12-Dec-2018 19:47:31.016 Ascend Vel PID Values 0.050000 0.660000 0.657837 0.647870 -2356895546704005900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 81272260231172618000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:31.016 Ascend SBE41 Message 13.00, 22.2873, 34.1920 13.000000 13.670242 -0.000030 0.660000 0.335000 0.074191 1.000000 $ 12-Dec-2018 19:47:32.050 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.000000 150.928810 27.475000 324.000000 $ 12-Dec-2018 19:47:32.015 Ascend Vel PID Values 0.050000 0.590000 0.590229 -0.067607 68349970854416172000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2356895546704005900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:32.015 Ascend SBE41 Message 12.41, 22.2877, 34.1921 12.410000 13.667752 0.000281 0.590000 0.625000 0.071759 1.000000 $ 12-Dec-2018 19:47:33.058 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.410000 150.921486 27.475000 324.000000 $ 12-Dec-2018 19:47:33.014 Ascend Vel PID Values 0.050000 0.020000 0.021897 -0.568333 -1982149154778068800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 68349970854416172000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:33.014 Ascend SBE41 Message 12.39, 22.2883, 34.1917 12.390000 13.646314 0.002963 0.020000 0.305000 0.068891 1.000000 $ 12-Dec-2018 19:47:34.088 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 150.928840 27.475000 324.000000 $ 12-Dec-2018 19:47:34.013 Ascend Vel PID Values 0.050000 0.000000 0.000070 -0.021827 57482325488563991000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1982149154778068800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:34.013 Ascend SBE41 Message 12.39, 22.2888, 34.1917 12.390000 13.556809 0.014125 0.000000 0.010000 0.065852 1.000000 $ 12-Dec-2018 19:47:35.049 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 150.927618 27.475000 324.000000 $ 12-Dec-2018 19:47:35.012 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009897 -1666987439168355800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 57482325488563991000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:35.012 Ascend SBE41 Message 12.38, 22.2886, 34.1924 12.380000 13.343936 0.040586 0.010000 0.005000 0.063186 1.000000 $ 12-Dec-2018 19:47:36.049 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.380000 150.939710 27.475000 324.000000 $ 12-Dec-2018 19:47:36.011 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019901 48342635735882326000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1666987439168355800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:36.011 Ascend SBE41 Message 12.39, 22.2891, 34.1925 12.390000 13.023784 0.080250 -0.010000 0.000000 0.061615 1.000000 $ 12-Dec-2018 19:47:37.049 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 151.060551 27.475000 324.000000 $ 12-Dec-2018 19:47:37.009 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009901 -1401936436340587700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 48342635735882326000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:37.009 Ascend SBE41 Message 12.39, 22.2893, 34.1924 12.390000 12.706345 0.119450 0.000000 -0.005000 0.061640 1.000000 $ 12-Dec-2018 19:47:38.046 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 151.070483 27.475000 324.000000 $ 12-Dec-2018 19:47:38.009 Ascend Vel PID Values 0.050000 0.040000 0.039867 0.039900 40656156653877044000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1401936436340587700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:38.009 Ascend SBE41 Message 12.35, 22.2897, 34.1927 12.350000 12.498203 0.145079 0.040000 0.020000 0.063197 1.000000 $ 12-Dec-2018 19:47:39.048 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.350000 151.130661 27.475000 324.000000 $ 12-Dec-2018 19:47:39.008 Ascend Vel PID Values 0.050000 0.160001 0.159601 0.119734 -1179028542962434200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 40656156653877044000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:39.008 Ascend SBE41 Message 12.19, 22.2902, 34.1924 12.190000 12.410755 0.155822 0.160001 0.100000 0.065723 1.000000 $ 12-Dec-2018 19:47:40.047 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.190000 151.151694 27.475000 324.000000 $ 12-Dec-2018 19:47:40.007 Ascend Vel PID Values 0.050000 -0.280001 -0.278537 -0.438138 34191827745910592000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1179028542962434200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:40.007 Ascend SBE41 Message 12.47, 22.2910, 34.1920 12.470000 12.387865 0.158357 -0.280001 -0.060000 0.068506 1.000000 $ 12-Dec-2018 19:47:41.047 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.470000 151.237167 27.475000 324.000000 $ 12-Dec-2018 19:47:41.492 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:47:41.006 Ascend Vel PID Values 0.050000 -0.610000 -0.608899 -0.330362 -991563004631407110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 34191827745910592000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:41.006 Ascend SBE41 Message 13.08, 22.2912, 34.1920 13.080000 12.378183 0.156890 -0.610000 -0.445000 0.071069 1.000000 $ 12-Dec-2018 19:47:42.149 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.080000 151.278540 27.475000 324.000000 $ 12-Dec-2018 19:47:42.005 Ascend Vel PID Values 0.050000 0.000000 -0.002028 0.606871 28755327134310806000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -991563004631407110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:42.005 Ascend SBE41 Message 13.08, 22.2916, 34.1920 13.080000 12.362964 0.147672 0.000000 -0.305000 0.073196 1.000000 $ 12-Dec-2018 19:47:43.047 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.080000 151.424497 27.475000 324.000000 $ 12-Dec-2018 19:47:43.492 Ascend MSC: OUT: SL $ 12-Dec-2018 19:47:43.004 Ascend Vel PID Values 0.050000 -0.010000 -0.009970 -0.007942 -833904486895013380000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 28755327134310806000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:43.004 Ascend SBE41 Message 13.09, 22.2916, 34.1912 13.090000 12.364199 0.121165 -0.010000 -0.005000 0.074832 1.000000 $ 12-Dec-2018 19:47:44.152 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.090000 151.418731 27.475000 324.000000 $ 12-Dec-2018 19:47:44.493 Ascend MSC: RX: 0xECA7,pH,01/31/2012 02:12:47,0,-1.00,-1.0000,-1.0000,258,147,0,23.41,56.47,11.744,4.660e-02,7.1234,0.000,-1.013421,0.000836,-1..816e-09,+2.027e-07 $ 12-Dec-2018 19:47:44.500 Ascend MSC: Data: 0xECA7,pH,01/31/2012 02:12:47,0,-1.00,-1.0000,-1.0000,258,147,0,23.41,56.47,11.744,4.660e-02,7.1234,0.000,-1.013421,0.000836,-1..816e-09,+2.027e-07 $ 12-Dec-2018 19:47:44.041 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019904 24183230119955389000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -833904486895013380000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:44.041 Ascend SBE41 Message 13.08, 22.2920, 34.1923 13.080000 12.438144 0.072419 0.010000 0.000000 0.075694 1.000000 $ 12-Dec-2018 19:47:45.056 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019868 -701313673478706320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 24183230119955389000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:45.056 Ascend SBE41 Message 13.09, 22.2924, 34.1923 13.090000 12.612402 0.011619 -0.010000 0.000000 0.075379 1.000000 $ 12-Dec-2018 19:47:45.615 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.090000 151.595280 27.475000 324.000000 $ 12-Dec-2018 19:47:45.727 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2348888 $ 12-Dec-2018 19:47:45.830 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:47:45.835 Ascend MSC: OUT: SLP $ 12-Dec-2018 19:47:46.034 Ascend Vel PID Values 0.050000 0.140000 0.139501 0.149435 20338096530882484000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -701313673478706320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:46.034 Ascend SBE41 Message 12.95, 22.2930, 34.1921 12.950000 12.827972 -0.040777 0.140000 0.065000 0.073857 1.000000 $ 12-Dec-2018 19:47:46.593 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.950000 151.582159 27.475000 324.000000 $ 12-Dec-2018 19:47:46.734 Ascend MSC: RX: ACK,SLP $ 12-Dec-2018 19:47:46.941 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.950000 151.579425 27.475000 324.000000 $ 12-Dec-2018 19:47:47.053 Ascend Vel PID Values 0.050000 1.190000 1.186505 1.047003 -589804799395592020000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 20338096530882484000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:47.053 Ascend SBE41 Message 11.76, 22.2935, 34.1925 11.760000 12.989599 -0.071592 1.190000 0.665000 0.071324 1.000000 $ 12-Dec-2018 19:47:48.087 Ascend Vel PID Values 0.050000 0.240000 0.243155 -0.943349 17104339182472169000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -589804799395592020000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:48.087 Ascend SBE41 Message 11.52, 22.2936, 34.1929 11.520000 13.056465 -0.082715 0.240000 0.715000 0.068143 1.000000 $ 12-Dec-2018 19:47:48.645 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 11.520000 151.584804 27.475000 324.000000 $ 12-Dec-2018 19:47:48.756 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0225629 $ 12-Dec-2018 19:47:48.867 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:47:48.971 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:47:49.489 Ascend Sending FLBB run command $ 12-Dec-2018 19:47:49.493 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:47:49.074 Ascend Vel PID Values 0.050000 0.000000 0.000804 -0.242351 -496025836291692900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 17104339182472169000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:49.074 Ascend SBE41 Message 11.52, 22.2939, 34.1927 11.520000 13.026895 -0.080275 0.000000 0.120000 0.064711 1.000000 $ 12-Dec-2018 19:47:50.052 Ascend Radiometer Message SATFI40287,-0.0059,0.0010,-0.0065,-0.2296 $ 12-Dec-2018 19:47:50.051 Ascend Vel PID Values 0.050000 -0.009999 -0.009965 -0.010769 14384749252459094000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -496025836291692900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:50.051 Ascend SBE41 Message 11.53, 22.2945, 34.1926 11.530000 12.865237 -0.062172 -0.009999 -0.005000 0.061496 1.000000 $ 12-Dec-2018 19:47:50.723 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.530000 151.740938 27.475000 324.000000 $ 12-Dec-2018 19:47:50.836 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0743711 $ 12-Dec-2018 19:47:50.842 Ascend Starting ISUS sample $ 12-Dec-2018 19:47:51.043 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 12-Dec-2018 19:47:51.146 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:51.401 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:50.566 Ascend Optode Message 4330,1532,263.367,22.740,29.113,29.043,36.155,7.111,536.2,464.7,102.6 $ 12-Dec-2018 19:47:50.569 Ascend Optode Message # $ 12-Dec-2018 19:47:51.633 Ascend FLBB Message /99/99,99:99:99,695,2304,700,4130,532 $ 12-Dec-2018 19:47:51.041 Ascend Vel PID Values 0.050000 -0.020000 -0.019967 -0.010002 -417157728321313710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 14384749252459094000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:51.041 Ascend SBE41 Message 11.55, 22.2949, 34.1897 11.550000 12.537861 -0.021523 -0.020000 -0.015000 0.059069 1.000000 $ 12-Dec-2018 19:47:52.200 Ascend MSC: RX: $ 12-Dec-2018 19:47:52.204 Ascend MSC: RX: $ 12-Dec-2018 19:47:52.403 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:52.407 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:52.081 Ascend Vel PID Values 0.050000 0.110001 0.109568 0.129535 12097574121318099000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -417157728321313710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:52.081 Ascend SBE41 Message 11.44, 22.2951, 34.1928 11.440000 12.121353 0.039158 0.110001 0.045000 0.057686 1.000000 $ 12-Dec-2018 19:47:53.066 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.440000 152.241930 27.475000 324.000000 $ 12-Dec-2018 19:47:53.177 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3357322 $ 12-Dec-2018 19:47:52.994 Ascend Vel PID Values 0.050000 0.169999 0.169799 0.060231 -350829649518224870000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 12097574121318099000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:52.994 Ascend SBE41 Message 11.27, 22.2952, 34.1931 11.270000 11.776748 0.103368 0.169999 0.140000 0.057043 1.000000 $ 12-Dec-2018 19:47:53.843 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.270000 152.744748 27.475000 324.000000 $ 12-Dec-2018 19:47:54.186 Ascend MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 12-Dec-2018 19:47:53.993 Ascend Vel PID Values 0.050000 -1.070000 -1.065874 -1.235672 10174059836028520000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -350829649518224870000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:53.993 Ascend SBE41 Message 12.34, 22.2961, 34.1923 12.340000 11.593074 0.152784 -1.070000 -0.450000 0.056569 1.000000 $ 12-Dec-2018 19:47:54.855 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 12.340000 152.746111 27.475000 324.000000 $ 12-Dec-2018 19:47:55.185 Ascend MSC: RX: NAK,CTD,EConvertErr: 0 $ 12-Dec-2018 19:47:55.191 Ascend MSC: EConvertErr: 0 $ 12-Dec-2018 19:47:54.992 Ascend Vel PID Values 0.050000 -0.059999 -0.063354 1.002520 -295047735244827090000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 10174059836028520000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:54.992 Ascend SBE41 Message 12.40, 22.2969, 34.1921 12.400000 11.527289 0.180934 -0.059999 -0.565000 0.056125 1.000000 $ 12-Dec-2018 19:47:55.945 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 12.400000 152.738430 27.475000 324.000000 $ 12-Dec-2018 19:47:56.057 Ascend Vel PID Values 0.050000 0.000000 -0.000205 0.063148 8556384322099985000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -295047735244827090000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:56.057 Ascend SBE41 Message 12.40, 22.2966, 34.1926 12.400000 11.512581 0.191021 0.000000 -0.030000 0.056059 1.000000 $ 12-Dec-2018 19:47:56.741 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 12.400000 152.884014 27.475000 324.000000 $ 12-Dec-2018 19:47:57.185 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:57.441 Ascend MSC: OUT: W $ 12-Dec-2018 19:47:56.990 Ascend Vel PID Values 0.050000 0.009999 0.009966 0.010171 -248135145340899570000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0000 8556384322099985000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:56.990 Ascend SBE41 Message 12.39, 22.2967, 34.1929 12.390000 11.564989 0.180858 0.009999 0.005000 0.056590 1.000000 $ 12-Dec-2018 19:47:57.908 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:57.912 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:58.314 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 12.390000 152.870961 27.475000 324.000000 $ 12-Dec-2018 19:47:58.426 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2411073 $ 12-Dec-2018 19:47:58.529 Ascend MSC: OUT: MODE,1 $ 12-Dec-2018 19:47:58.638 Ascend MSC: RX: ACK $ 12-Dec-2018 19:47:58.642 Ascend MSC: Got ACK $ 12-Dec-2018 19:47:58.129 Ascend Vel PID Values 0.050000 -0.009999 -0.009933 -0.019898 7195919214886087800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0000 -248135145340899570000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:58.129 Ascend SBE41 Message 12.40, 22.2980, 34.1919 12.400000 11.739105 0.139300 -0.009999 0.000000 0.057217 1.000000 $ 12-Dec-2018 19:47:59.206 Ascend MSC: RX: ACK,MODE,1 $ 12-Dec-2018 19:47:59.091 Ascend Vel PID Values 0.050000 -0.010000 -0.010000 -0.000067 -208681657231696540000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0 7195919214886087800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:47:59.091 Ascend SBE41 Message 12.41, 22.2978, 34.1925 12.410000 12.003040 0.066145 -0.010000 -0.010000 0.057234 1.000000 $ 12-Dec-2018 19:47:59.876 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 12.410000 153.220423 27.475000 324.000000 $ 12-Dec-2018 19:47:59.988 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4597839 $ 12-Dec-2018 19:47:59.987 Ascend Vel PID Values 0.050000 0.920000 0.916905 0.926905 6051768059719199500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0 -208681657231696540000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:47:59.987 Ascend SBE41 Message 11.49, 22.2982, 34.1928 11.490000 12.235184 -0.014095 0.920000 0.455000 0.056355 1.000000 $ 12-Dec-2018 19:48:00.648 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.490000 153.236412 27.475000 324.000000 $ 12-Dec-2018 19:48:00.997 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:48:00.985 Ascend Vel PID Values 0.050000 0.639999 0.640926 -0.275979 -17550127373185679000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 6051768059719199500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.0 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:00.985 Ascend SBE41 Message 10.85, 22.2988, 34.1928 10.850000 12.354250 -0.071457 0.639999 0.780000 0.054868 1.000000 $ 12-Dec-2018 19:48:01.654 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.850000 153.214738 27.475000 324.000000 $ 12-Dec-2018 19:48:01.983 Ascend Vel PID Values 0.050000 -0.009999 -0.007835 -0.648761 508953693822384660000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -17550127373185679000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:01.983 Ascend SBE41 Message 10.86, 22.2990, 34.1929 10.860000 12.362992 -0.095272 -0.009999 0.315000 0.053107 1.000000 $ 12-Dec-2018 19:48:02.551 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.860000 153.203905 27.475000 324.000000 $ 12-Dec-2018 19:48:02.997 Ascend MSC: OUT: TS $ 12-Dec-2018 19:48:02.983 Ascend Vel PID Values 0.050000 0.000000 -0.000030 0.007805 -14759657120849155000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 508953693822384660000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:02.983 Ascend SBE41 Message 10.86, 22.2995, 34.1929 10.860000 12.254215 -0.089965 0.000000 -0.005000 0.051489 1.000000 $ 12-Dec-2018 19:48:03.656 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.860000 153.195389 27.475000 324.000000 $ 12-Dec-2018 19:48:03.998 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:48:03.982 Ascend Vel PID Values 0.050000 0.009999 0.009966 0.009996 428030056504625440000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -14759657120849155000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:03.982 Ascend SBE41 Message 10.85, 22.2991, 34.1932 10.850000 11.986115 -0.058621 0.009999 0.005000 0.050581 1.000000 $ 12-Dec-2018 19:48:04.656 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.850000 153.237708 27.475000 324.000000 $ 12-Dec-2018 19:48:04.981 Ascend Vel PID Values 0.050000 0.060000 0.059834 0.049868 -12412871638634137000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 428030056504625440000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:04.981 Ascend SBE41 Message 10.79, 22.3000, 34.1928 10.790000 11.590467 -0.003183 0.060000 0.035000 0.050801 1.000000 $ 12-Dec-2018 19:48:05.553 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.790000 153.238796 27.475000 324.000000 $ 12-Dec-2018 19:48:05.980 Ascend Vel PID Values 0.050000 0.130000 0.129767 0.069933 359973277520389950000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -12412871638634137000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:05.980 Ascend SBE41 Message 10.66, 22.3001, 34.1934 10.660000 11.210187 0.065420 0.130000 0.095000 0.052025 1.000000 $ 12-Dec-2018 19:48:06.554 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.660000 153.297961 27.475000 324.000000 $ 12-Dec-2018 19:48:06.979 Ascend Vel PID Values 0.050000 -0.820000 -0.816839 -0.946606 -10439225048091308000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 359973277520389950000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:06.979 Ascend SBE41 Message 11.48, 22.3007, 34.1929 11.480000 10.969797 0.127834 -0.820000 -0.345000 0.053663 1.000000 $ 12-Dec-2018 19:48:07.559 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.480000 153.306723 27.475000 324.000000 $ 12-Dec-2018 19:48:07.979 Ascend Vel PID Values 0.050000 -0.270000 -0.271825 0.545013 302737526394647940000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -10439225048091308000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:07.979 Ascend SBE41 Message 11.75, 22.3011, 34.1927 11.750000 10.867778 0.169191 -0.270000 -0.545000 0.055165 1.000000 $ 12-Dec-2018 19:48:08.556 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.750000 153.320342 27.475000 324.000000 $ 12-Dec-2018 19:48:08.978 Ascend Vel PID Values 0.050000 -0.010000 -0.010869 0.260957 -87793882654447901000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 302737526394647940000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:08.978 Ascend SBE41 Message 11.76, 22.3017, 34.1919 11.760000 10.841988 0.187113 -0.010000 -0.140000 0.056238 1.000000 $ 12-Dec-2018 19:48:09.555 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.760000 153.322689 27.475000 324.000000 $ 12-Dec-2018 19:48:09.977 Ascend Vel PID Values 0.050000 0.010000 0.009932 0.020801 254602259697898910000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -87793882654447901000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:09.977 Ascend SBE41 Message 11.75, 22.3020, 34.1912 11.750000 10.887862 0.182505 0.010000 0.000000 0.056617 1.000000 $ 12-Dec-2018 19:48:10.266 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:48:10.668 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.750000 153.456435 27.475000 324.000000 $ 12-Dec-2018 19:48:10.976 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009899 -73834655312390690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 254602259697898910000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:10.976 Ascend SBE41 Message 11.75, 22.3014, 34.1931 11.750000 11.048101 0.149205 0.000000 0.005000 0.055891 1.000000 $ 12-Dec-2018 19:48:11.564 Ascend PTH Message 798.161865 24.000000 54.649872 24.997429 $ 12-Dec-2018 19:48:11.767 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.750000 153.451405 27.775000 193.000000 $ 12-Dec-2018 19:48:12.010 Ascend MSC: OUT: SL $ 12-Dec-2018 19:48:11.974 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010000 214120500405933030000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -73834655312390690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:11.974 Ascend SBE41 Message 11.76, 22.3019, 34.1930 11.760000 11.302965 0.084498 -0.010000 -0.005000 0.053749 1.000000 $ 12-Dec-2018 19:48:13.668 Ascend Error executing 2485 Transaction = 0 $ 12-Dec-2018 19:48:13.673 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.760000 250.000000 27.775000 193.000000 $ 12-Dec-2018 19:48:13.883 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8737796 $ 12-Dec-2018 19:48:13.988 Ascend MSC: RX: 0x097E,A,01/31/2012 02:13:14,0,-1.00,-1.0000,-1.0000,231,147,1,65,23.50,56.47,11.576,5.232e-01,10524.00,2247.00,1201.43,12.66,-2ED3CBD3C393C833DF04018430947064C2651DE58355F2065EE6C6E71E275A977BB7856773674A771046D0268E2651161B65F365DA15CD45CF65DF15FD3624C659969886E37733178C87ECE84AE8A118F17934496109795975F958592248DA088188815C60777B346977744AD78761E0D4266DD903266684E12A655F11C18651BBC6555F83556F55D5A81955C3D34055CC1F3604FA54E9C4DDD4D974D8B,6631.6 $ 12-Dec-2018 19:48:14.000 Ascend MSC: Data: 0x097E,A,01/31/2012 02:13:14,0,-1.00,-1.0000,-1.0000,231,147,1,65,23.50,56.47,11.576,5.232e-01,10524.00,2247.00,1201.43,12.66,-2ED3CBD3C393C833DF04018430947064C2651DE58355F2065EE6C6E71E275A977BB7856773674A771046D0268E2651161B65F365DA15CD45CF65DF15FD3624C659969886E37733178C87ECE84AE8A118F17934496109795975F958592248DA088188815C60777B346977744AD78761E0D4266DD903266684E12A655F11C18651BBC6555F83556F55D5A81955C3D34055CC1F3604FA54E9C4DDD4D974D8B,6631.6 $ 12-Dec-2018 19:48:12.973 Ascend Vel PID Values 0.050000 0.720000 0.717571 0.727538 -62094945117720578000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 214120500405933030000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:12.973 Ascend SBE41 Message 11.04, 22.3026, 34.1929 11.040000 11.546027 0.005482 0.720000 0.355000 0.050354 1.000000 $ 12-Dec-2018 19:48:13.987 Ascend Vel PID Values 0.050000 0.840000 0.839597 0.122026 180075340841389690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -62094945117720578000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:13.987 Ascend SBE41 Message 10.20, 22.3029, 34.1933 10.200000 11.688521 -0.059192 0.840000 0.780000 0.046382 1.000000 $ 12-Dec-2018 19:48:15.125 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.200000 153.507911 27.775000 193.000000 $ 12-Dec-2018 19:48:15.238 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3500980 $ 12-Dec-2018 19:48:15.341 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:48:15.345 Ascend Starting pH sample $ 12-Dec-2018 19:48:15.447 Ascend MSC: OUT: W $ 12-Dec-2018 19:48:15.897 Ascend MSC: OUT: W $ 12-Dec-2018 19:48:14.971 Ascend Vel PID Values 0.050000 0.010000 0.012762 -0.826835 -52221848844003009000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 180075340841389690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:14.971 Ascend SBE41 Message 10.19, 22.3030, 34.1934 10.190000 11.717847 -0.092567 0.010000 0.425000 0.042775 1.000000 $ 12-Dec-2018 19:48:16.354 Ascend MSC: RX: ACK $ 12-Dec-2018 19:48:16.358 Ascend MSC: Got ACK $ 12-Dec-2018 19:48:15.999 Ascend Vel PID Values 0.050000 0.000000 0.000038 -0.012724 151443361647608720000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -52221848844003009000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:15.999 Ascend SBE41 Message 10.19, 22.3033, 34.1934 10.190000 11.628220 -0.094110 0.000000 0.005000 0.040417 1.000000 $ 12-Dec-2018 19:48:16.912 Ascend MSC: RX: ACK $ 12-Dec-2018 19:48:17.014 Ascend MSC: Got ACK $ 12-Dec-2018 19:48:17.319 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.190000 154.031537 27.775000 193.000000 $ 12-Dec-2018 19:48:17.430 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1861628 $ 12-Dec-2018 19:48:17.533 Ascend MSC: OUT: MODE,2 $ 12-Dec-2018 19:48:17.014 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000038 -43918574877806527000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 151443361647608720000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:17.014 Ascend SBE41 Message 10.19, 22.3036, 34.1935 10.190000 11.381202 -0.066746 0.000000 0.000000 0.039923 1.000000 $ 12-Dec-2018 19:48:18.194 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.190000 154.480159 27.775000 193.000000 $ 12-Dec-2018 19:48:18.435 Ascend MSC: RX: ACK,MODE,2 $ 12-Dec-2018 19:48:18.013 Ascend Vel PID Values 0.050000 0.040000 0.039867 0.039867 127363867145638910000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -43918574877806527000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:18.013 Ascend SBE41 Message 10.15, 22.3041, 34.1933 10.150000 10.994075 -0.013174 0.040000 0.020000 0.041405 1.000000 $ 12-Dec-2018 19:48:19.092 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.150000 154.674940 27.775000 193.000000 $ 12-Dec-2018 19:48:18.965 Ascend Vel PID Values 0.050000 0.150000 0.149633 0.109766 -36935521472235283000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 127363867145638910000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:18.965 Ascend SBE41 Message 10.00, 22.3043, 34.1934 10.000000 10.597750 0.055696 0.150000 0.095000 0.044401 1.000000 $ 12-Dec-2018 19:48:19.990 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.000000 154.688656 27.775000 193.000000 $ 12-Dec-2018 19:48:20.435 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:48:20.544 Ascend ERROR: Missed PH message 7 $ 12-Dec-2018 19:48:20.648 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:48:20.652 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:48:21.255 Ascend Sending FLBB run command $ 12-Dec-2018 19:48:21.271 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:48:19.966 Ascend Vel PID Values 0.050000 -0.410000 -0.408137 -0.557770 107113012269482320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -36935521472235283000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:19.966 Ascend SBE41 Message 10.41, 22.3050, 34.1929 10.410000 10.330328 0.120333 -0.410000 -0.130000 0.048126 1.000000 $ 12-Dec-2018 19:48:20.965 Ascend Vel PID Values 0.050000 -0.660000 -0.659165 -0.251028 -31062773558149873000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 107113012269482320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:20.965 Ascend SBE41 Message 11.07, 22.3054, 34.1928 11.070000 10.210706 0.165221 -0.660000 -0.535000 0.051942 1.000000 $ 12-Dec-2018 19:48:22.091 Ascend Radiometer Message SATFI40287,-0.0057,0.0014,-0.0067,-0.2143 $ 12-Dec-2018 19:48:21.972 Ascend Vel PID Values 0.050000 0.009999 0.007771 0.666936 900820433186346400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -31062773558149873000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:21.972 Ascend SBE41 Message 11.06, 22.3054, 34.1930 11.060000 10.172424 0.187589 0.009999 -0.325000 0.055551 1.000000 $ 12-Dec-2018 19:48:22.870 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 11.060000 154.763073 27.775000 193.000000 $ 12-Dec-2018 19:48:22.983 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.5481651 $ 12-Dec-2018 19:48:23.086 Ascend MSC: OUT: TS $ 12-Dec-2018 19:48:22.345 Ascend Optode Message 4330,1532,263.254,22.754,29.112,29.042,36.152,7.109,536.1,464.5,102.1 $ 12-Dec-2018 19:48:22.348 Ascend Optode Message # $ 12-Dec-2018 19:48:23.319 Ascend FLBB Message /99/99,99:99:99,695,2299,700,4130,532 $ 12-Dec-2018 19:48:22.981 Ascend Vel PID Values 0.050000 0.000000 0.000030 -0.007742 -26123792562404045000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 900820433186346400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:22.981 Ascend SBE41 Message 11.06, 22.3060, 34.1929 11.060000 10.187605 0.189324 0.000000 0.005000 0.058687 1.000000 $ 12-Dec-2018 19:48:23.883 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:48:24.189 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 11.060000 154.599242 27.775000 193.000000 $ 12-Dec-2018 19:48:24.300 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3120638 $ 12-Dec-2018 19:48:23.986 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000029 757589984309717360000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -26123792562404045000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:23.986 Ascend SBE41 Message 11.06, 22.3062, 34.1929 11.060000 10.297929 0.164565 0.000000 0.000000 0.060712 1.000000 $ 12-Dec-2018 19:48:24.960 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 11.060000 154.559374 27.775000 193.000000 $ 12-Dec-2018 19:48:25.070 Ascend Vel PID Values 0.050000 -0.009999 -0.009966 -0.009966 -21970109544981802000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 757589984309717360000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:25.070 Ascend SBE41 Message 11.07, 22.3067, 34.1928 11.070000 10.520564 0.106452 -0.009999 -0.005000 0.060817 1.000000 $ 12-Dec-2018 19:48:25.863 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 11.070000 154.573672 27.775000 193.000000 $ 12-Dec-2018 19:48:25.973 Ascend Vel PID Values 0.050000 0.290000 0.289002 0.298968 637133176804472310000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -21970109544981802000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:25.973 Ascend SBE41 Message 10.78, 22.3066, 34.1931 10.780000 10.777037 0.026834 0.290000 0.140000 0.058787 1.000000 $ 12-Dec-2018 19:48:26.864 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.780000 154.583119 27.775000 193.000000 $ 12-Dec-2018 19:48:26.974 Ascend Vel PID Values 0.050000 1.150000 1.147136 0.858134 -18476862127329697000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 637133176804472310000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:26.974 Ascend SBE41 Message 9.63, 22.3073, 34.1932 9.630000 10.959552 -0.044771 1.150000 0.720000 0.055076 1.000000 $ 12-Dec-2018 19:48:27.867 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.630000 154.588252 27.775000 193.000000 $ 12-Dec-2018 19:48:27.977 Ascend Vel PID Values 0.050000 0.110000 0.113456 -1.033680 535829001692561220000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -18476862127329697000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:27.977 Ascend SBE41 Message 9.52, 22.3069, 34.1939 9.520000 11.028551 -0.086396 0.110000 0.630000 0.050469 1.000000 $ 12-Dec-2018 19:48:28.863 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.520000 154.651687 27.775000 193.000000 $ 12-Dec-2018 19:48:28.973 Ascend Vel PID Values 0.050000 -0.009999 -0.009594 -0.123050 -15539041049084275000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 535829001692561220000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:28.973 Ascend SBE41 Message 9.53, 22.3078, 34.1934 9.530000 10.985752 -0.095912 -0.009999 0.050000 0.045757 1.000000 $ 12-Dec-2018 19:48:29.863 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.530000 154.656455 27.775000 193.000000 $ 12-Dec-2018 19:48:29.973 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009562 450632190423443950000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -15539041049084275000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:29.973 Ascend SBE41 Message 9.53, 22.3078, 34.1933 9.530000 10.799810 -0.077653 0.000000 -0.005000 0.041968 1.000000 $ 12-Dec-2018 19:48:30.864 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.530000 154.788814 27.775000 193.000000 $ 12-Dec-2018 19:48:30.974 Ascend Vel PID Values 0.050000 0.040000 0.039867 0.039899 -13068333522279874000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 450632190423443950000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:30.974 Ascend SBE41 Message 9.49, 22.3086, 34.1934 9.490000 10.454201 -0.033019 0.040000 0.020000 0.040318 1.000000 $ 12-Dec-2018 19:48:31.878 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.490000 154.784128 27.775000 193.000000 $ 12-Dec-2018 19:48:31.989 Ascend Vel PID Values 0.050000 0.099999 0.099800 0.059933 378981672146116330000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -13068333522279874000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:31.989 Ascend SBE41 Message 9.39, 22.3087, 34.1937 9.390000 10.045326 0.031225 0.099999 0.070000 0.041369 1.000000 $ 12-Dec-2018 19:48:32.863 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.390000 154.839203 27.775000 193.000000 $ 12-Dec-2018 19:48:32.973 Ascend Vel PID Values 0.050000 0.120000 0.119933 0.020133 -10990468492237375000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 378981672146116330000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:32.973 Ascend SBE41 Message 9.27, 22.3093, 34.1935 9.270000 9.729484 0.097864 0.120000 0.110000 0.044529 1.000000 $ 12-Dec-2018 19:48:33.864 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.270000 154.832341 27.775000 193.000000 $ 12-Dec-2018 19:48:34.306 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:48:33.974 Ascend Vel PID Values 0.050000 -0.780000 -0.777005 -0.896938 318723586274883870000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -10990468492237375000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:33.974 Ascend SBE41 Message 10.05, 22.3092, 34.1935 10.050000 9.569287 0.149434 -0.780000 -0.330000 0.048600 1.000000 $ 12-Dec-2018 19:48:34.965 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.050000 154.887654 27.775000 193.000000 $ 12-Dec-2018 19:48:34.950 Ascend Vel PID Values 0.050000 -0.220000 -0.221859 0.555146 -92429840019716315000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 318723586274883870000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:34.950 Ascend SBE41 Message 10.27, 22.3097, 34.1933 10.270000 9.505828 0.179873 -0.220000 -0.500000 0.052779 1.000000 $ 12-Dec-2018 19:48:35.861 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.270000 154.888012 27.775000 193.000000 $ 12-Dec-2018 19:48:36.306 Ascend MSC: OUT: SL $ 12-Dec-2018 19:48:35.973 Ascend Vel PID Values 0.050000 -0.009999 -0.010701 0.211158 268046536057177320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -92429840019716315000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:35.973 Ascend SBE41 Message 10.28, 22.3101, 34.1932 10.280000 9.476808 0.191988 -0.009999 -0.115000 0.056718 1.000000 $ 12-Dec-2018 19:48:36.967 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.280000 154.909424 27.775000 193.000000 $ 12-Dec-2018 19:48:37.307 Ascend MSC: RX: 0x3B62,pH,01/31/2012 02:13:40,0,-1.00,-1.0000,-1.0000,259,147,0,23.52,56.47,11.744,4.620e-02,7.1234,0.000,-1.014991,0.000957,-1. $ 12-Dec-2018 19:48:37.410 Ascend MSC: Data: 0x3B62,pH,01/31/2012 02:13:40,0,-1.00,-1.0000,-1.0000,259,147,0,23.52,56.47,11.744,4.620e-02,7.1234,0.000,-1.014991,0.000957,-1. $ 12-Dec-2018 19:48:36.949 Ascend Vel PID Values 0.050000 0.009999 0.009932 0.020633 -77733495456581422000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 268046536057177320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:36.949 Ascend SBE41 Message 10.27, 22.3102, 34.1933 10.270000 9.502911 0.183439 0.009999 0.000000 0.060002 1.000000 $ 12-Dec-2018 19:48:38.071 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.270000 154.888533 27.775000 193.000000 $ 12-Dec-2018 19:48:38.306 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:48:38.407 Ascend MSC: OUT: SLP $ 12-Dec-2018 19:48:37.949 Ascend Vel PID Values 0.050000 -0.009999 -0.009933 -0.019864 Infinity -77733495456581422000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 12-Dec-2018 19:48:37.949 Ascend SBE41 Message 10.28, 22.3105, 34.1934 10.280000 9.639658 0.143501 -0.009999 0.000000 0.061684 1.000000 $ 12-Dec-2018 19:48:39.064 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.280000 154.953957 27.775000 193.000000 $ 12-Dec-2018 19:48:39.306 Ascend MSC: RX: ACK,SLP $ 12-Dec-2018 19:48:38.947 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009900 NaN Infinity 50.000000 409600.000000 1.000000 $ 12-Dec-2018 19:48:38.947 Ascend SBE41 Message 10.28, 22.3112, 34.1931 10.280000 9.869349 0.072332 0.000000 -0.005000 0.061130 1.000000 $ 12-Dec-2018 19:48:39.955 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 10.280000 154.950216 27.775000 193.000000 $ 12-Dec-2018 19:48:39.943 Ascend Vel PID Values 0.050000 0.500000 0.498336 0.498369 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:39.943 Ascend SBE41 Message 9.78, 22.3113, 34.1934 9.780000 10.089641 -0.005491 0.500000 0.250000 0.058503 1.000000 $ 12-Dec-2018 19:48:40.852 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.780000 155.030027 27.775000 193.000000 $ 12-Dec-2018 19:48:40.962 Ascend Vel PID Values 0.050000 0.929999 0.928566 0.430230 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:40.962 Ascend SBE41 Message 8.85, 22.3117, 34.1936 8.850000 10.218365 -0.060487 0.929999 0.715000 0.054536 1.000000 $ 12-Dec-2018 19:48:41.850 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.850000 155.032732 27.775000 193.000000 $ 12-Dec-2018 19:48:41.960 Ascend Vel PID Values 0.050000 0.070001 0.072860 -0.855705 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:41.960 Ascend SBE41 Message 8.78, 22.3111, 34.1945 8.780000 10.248325 -0.084023 0.070001 0.500000 0.050025 1.000000 $ 12-Dec-2018 19:48:42.859 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.780000 155.033432 27.775000 193.000000 $ 12-Dec-2018 19:48:42.969 Ascend Vel PID Values 0.050000 0.009999 0.010204 -0.062656 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:42.969 Ascend SBE41 Message 8.77, 22.3119, 34.1941 8.770000 10.178575 -0.083257 0.009999 0.040000 0.045788 1.000000 $ 12-Dec-2018 19:48:43.870 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.770000 155.034222 27.775000 193.000000 $ 12-Dec-2018 19:48:43.980 Ascend Vel PID Values 0.050000 -0.009999 -0.009932 -0.020136 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:43.980 Ascend SBE41 Message 8.78, 22.3123, 34.1940 8.780000 9.968276 -0.060836 -0.009999 0.000000 0.042962 1.000000 $ 12-Dec-2018 19:48:44.852 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.780000 155.036964 27.775000 193.000000 $ 12-Dec-2018 19:48:44.962 Ascend Vel PID Values 0.050000 0.059999 0.059767 0.069699 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:44.962 Ascend SBE41 Message 8.72, 22.3127, 34.1939 8.720000 9.614999 -0.013898 0.059999 0.025000 0.042577 1.000000 $ 12-Dec-2018 19:48:45.851 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.720000 155.033648 27.775000 193.000000 $ 12-Dec-2018 19:48:45.962 Ascend Vel PID Values 0.050000 0.080000 0.079933 0.020166 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:45.962 Ascend SBE41 Message 8.64, 22.3127, 34.1943 8.640000 9.227316 0.050992 0.080000 0.070000 0.044704 1.000000 $ 12-Dec-2018 19:48:46.849 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.640000 155.040540 27.775000 193.000000 $ 12-Dec-2018 19:48:46.960 Ascend Vel PID Values 0.050000 0.100000 0.099934 0.020001 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:46.960 Ascend SBE41 Message 8.54, 22.3128, 34.1945 8.540000 8.944891 0.114365 0.100000 0.090000 0.048420 1.000000 $ 12-Dec-2018 19:48:47.850 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.540000 155.027330 27.775000 193.000000 $ 12-Dec-2018 19:48:47.961 Ascend Vel PID Values 0.050000 -0.990000 -0.986373 -1.086306 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:47.961 Ascend SBE41 Message 9.53, 22.3135, 34.1938 9.530000 8.806254 0.158789 -0.990000 -0.445000 0.052656 1.000000 $ 12-Dec-2018 19:48:48.851 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.530000 155.027293 27.775000 193.000000 $ 12-Dec-2018 19:48:48.962 Ascend Vel PID Values 0.050000 -0.040000 -0.043155 0.943217 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:48.962 Ascend SBE41 Message 9.57, 22.3143, 34.1935 9.570000 8.749903 0.181692 -0.040000 -0.515000 0.056811 1.000000 $ 12-Dec-2018 19:48:49.855 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.570000 155.034520 27.775000 193.000000 $ 12-Dec-2018 19:48:49.965 Ascend Vel PID Values 0.050000 -0.010000 -0.010105 0.033050 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:49.965 Ascend SBE41 Message 9.58, 22.3143, 34.1937 9.580000 8.729094 0.187961 -0.010000 -0.025000 0.060472 1.000000 $ 12-Dec-2018 19:48:50.851 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.580000 155.023359 27.775000 193.000000 $ 12-Dec-2018 19:48:50.961 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.010072 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:50.961 Ascend SBE41 Message 9.58, 22.3145, 34.1938 9.580000 8.778820 0.173157 0.000000 -0.005000 0.062930 1.000000 $ 12-Dec-2018 19:48:51.852 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.580000 155.035757 27.775000 193.000000 $ 12-Dec-2018 19:48:51.962 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.009934 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:51.962 Ascend SBE41 Message 9.59, 22.3150, 34.1936 9.590000 8.951043 0.125823 -0.010000 -0.005000 0.063350 1.000000 $ 12-Dec-2018 19:48:52.853 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.590000 155.009352 27.775000 193.000000 $ 12-Dec-2018 19:48:52.963 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009934 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:52.963 Ascend SBE41 Message 9.59, 22.3151, 34.1940 9.590000 9.205963 0.050588 0.000000 -0.005000 0.061456 1.000000 $ 12-Dec-2018 19:48:53.855 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 9.590000 155.034132 27.775000 193.000000 $ 12-Dec-2018 19:48:53.965 Ascend Vel PID Values 0.050000 0.820000 0.817271 0.817304 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:53.965 Ascend SBE41 Message 8.77, 22.3153, 34.1943 8.770000 9.426117 -0.024599 0.820000 0.410000 0.057765 1.000000 $ 12-Dec-2018 19:48:54.853 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.770000 155.034833 27.775000 193.000000 $ 12-Dec-2018 19:48:54.963 Ascend Vel PID Values 0.050000 0.690001 0.690429 -0.126842 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:54.963 Ascend SBE41 Message 8.08, 22.3158, 34.1944 8.080000 9.539280 -0.073542 0.690001 0.755000 0.053123 1.000000 $ 12-Dec-2018 19:48:55.854 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.080000 155.028880 27.775000 193.000000 $ 12-Dec-2018 19:48:55.964 Ascend Vel PID Values 0.050000 0.010000 0.012264 -0.678165 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:55.964 Ascend SBE41 Message 8.07, 22.3165, 34.1940 8.070000 9.550455 -0.092089 0.010000 0.350000 0.048373 1.000000 $ 12-Dec-2018 19:48:56.855 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.070000 155.043878 27.775000 193.000000 $ 12-Dec-2018 19:48:56.965 Ascend Vel PID Values 0.050000 0.009999 0.010003 -0.002261 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:56.965 Ascend SBE41 Message 8.06, 22.3166, 34.1943 8.060000 9.451179 -0.086790 0.009999 0.010000 0.044548 1.000000 $ 12-Dec-2018 19:48:57.856 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.060000 155.042961 27.775000 193.000000 $ 12-Dec-2018 19:48:57.966 Ascend Vel PID Values 0.050000 0.010000 0.010000 -0.000003 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:57.966 Ascend SBE41 Message 8.05, 22.3176, 34.1938 8.050000 9.197808 -0.058022 0.010000 0.010000 0.042777 1.000000 $ 12-Dec-2018 19:48:58.857 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.050000 155.046962 27.775000 193.000000 $ 12-Dec-2018 19:48:58.967 Ascend Vel PID Values 0.050000 0.070000 0.069801 0.059800 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:58.967 Ascend SBE41 Message 7.98, 22.3170, 34.1946 7.980000 8.814755 -0.004475 0.070000 0.040000 0.043603 1.000000 $ 12-Dec-2018 19:48:59.858 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 7.980000 155.040085 27.775000 193.000000 $ 12-Dec-2018 19:49:00.319 Ascend ERROR: Missed NO3 message 7 $ 12-Dec-2018 19:49:00.423 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:49:00.427 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:49:01.029 Ascend Sending FLBB run command $ 12-Dec-2018 19:49:01.048 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:48:59.968 Ascend Vel PID Values 0.050000 0.080000 0.079966 0.010166 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:48:59.968 Ascend SBE41 Message 7.90, 22.3176, 34.1944 7.900000 8.436075 0.063693 0.080000 0.075000 0.046512 1.000000 $ 12-Dec-2018 19:49:00.924 Ascend Vel PID Values 0.050000 -0.380000 -0.378469 -0.458435 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:00.924 Ascend SBE41 Message 8.28, 22.3179, 34.1944 8.280000 8.187047 0.126058 -0.380000 -0.150000 0.050441 1.000000 $ 12-Dec-2018 19:49:01.842 Ascend Radiometer Message SATFI40287,-0.0053,0.0017,-0.0058,-0.2177 $ 12-Dec-2018 19:49:01.940 Ascend Vel PID Values 0.050000 -0.590000 -0.589299 -0.210830 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:01.940 Ascend SBE41 Message 8.87, 22.3181, 34.1941 8.870000 8.074278 0.167262 -0.590000 -0.485000 0.054550 1.000000 $ 12-Dec-2018 19:49:02.505 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.870000 155.047260 27.775000 193.000000 $ 12-Dec-2018 19:49:02.616 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3032678 $ 12-Dec-2018 19:49:02.622 Ascend Starting ISUS sample $ 12-Dec-2018 19:49:02.824 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 12-Dec-2018 19:49:02.829 Ascend MSC: OUT: W $ 12-Dec-2018 19:49:03.183 Ascend MSC: OUT: W $ 12-Dec-2018 19:49:02.120 Ascend Optode Message 4330,1532,263.152,22.765,29.112,29.042,36.152,7.110,536.0,464.4,101.7 $ 12-Dec-2018 19:49:02.123 Ascend Optode Message # $ 12-Dec-2018 19:49:03.418 Ascend FLBB Message /99/99,99:99:99,695,2306,700,4130,532 $ 12-Dec-2018 19:49:02.927 Ascend Vel PID Values 0.050000 0.000000 -0.001962 0.587337 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:02.927 Ascend SBE41 Message 8.87, 22.3187, 34.1940 8.870000 8.034690 0.186162 0.000000 -0.295000 0.058350 1.000000 $ 12-Dec-2018 19:49:03.870 Ascend MSC: RX: $ 12-Dec-2018 19:49:04.070 Ascend MSC: RX: $ 12-Dec-2018 19:49:04.076 Ascend MSC: RX: ACK $ 12-Dec-2018 19:49:04.178 Ascend MSC: Got ACK $ 12-Dec-2018 19:49:04.579 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.870000 155.042998 27.775000 193.000000 $ 12-Dec-2018 19:49:04.690 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0683139 $ 12-Dec-2018 19:49:03.969 Ascend Vel PID Values 0.050000 0.010000 0.009964 0.011926 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:03.969 Ascend SBE41 Message 8.86, 22.3189, 34.1939 8.860000 8.048994 0.185760 0.010000 0.005000 0.061260 1.000000 $ 12-Dec-2018 19:49:05.024 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019897 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:05.024 Ascend SBE41 Message 8.87, 22.3190, 34.1943 8.870000 8.157035 0.160091 -0.010000 0.000000 0.062459 1.000000 $ 12-Dec-2018 19:49:05.688 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.870000 155.054599 27.775000 193.000000 $ 12-Dec-2018 19:49:05.799 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1037981 $ 12-Dec-2018 19:49:05.904 Ascend MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 12-Dec-2018 19:49:06.007 Ascend Vel PID Values 0.050000 -0.010000 -0.010000 -0.000066 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:06.007 Ascend SBE41 Message 8.88, 22.3191, 34.1944 8.880000 8.368562 0.102568 -0.010000 -0.010000 0.061481 1.000000 $ 12-Dec-2018 19:49:06.564 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.880000 155.042164 27.775000 193.000000 $ 12-Dec-2018 19:49:06.805 Ascend MSC: RX: NAK,CTD,EConvertErr: 0 $ 12-Dec-2018 19:49:06.908 Ascend MSC: EConvertErr: 0 $ 12-Dec-2018 19:49:07.117 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.880000 155.044183 27.775000 193.000000 $ 12-Dec-2018 19:49:07.012 Ascend Vel PID Values 0.050000 0.090000 0.089667 0.099667 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:07.012 Ascend SBE41 Message 8.79, 22.3201, 34.1916 8.790000 8.606817 0.025709 0.090000 0.040000 0.058475 1.000000 $ 12-Dec-2018 19:49:07.917 Ascend Vel PID Values 0.050000 1.040000 1.036838 0.947171 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:07.917 Ascend SBE41 Message 7.75, 22.3207, 34.1943 7.750000 8.774724 -0.041906 1.040000 0.565000 0.054178 1.000000 $ 12-Dec-2018 19:49:08.691 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.750000 155.045167 27.775000 193.000000 $ 12-Dec-2018 19:49:08.804 Ascend MSC: OUT: W $ 12-Dec-2018 19:49:09.059 Ascend MSC: OUT: W $ 12-Dec-2018 19:49:08.916 Ascend Vel PID Values 0.050000 0.330000 0.332357 -0.704481 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:08.916 Ascend SBE41 Message 7.42, 22.3204, 34.1949 7.420000 8.843188 -0.081189 0.330000 0.685000 0.049371 1.000000 $ 12-Dec-2018 19:49:09.504 Ascend MSC: RX: ACK $ 12-Dec-2018 19:49:09.508 Ascend MSC: Got ACK $ 12-Dec-2018 19:49:09.709 Ascend MSC: RX: ACK $ 12-Dec-2018 19:49:09.713 Ascend MSC: Got ACK $ 12-Dec-2018 19:49:10.016 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.420000 155.041859 27.775000 193.000000 $ 12-Dec-2018 19:49:10.128 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3241914 $ 12-Dec-2018 19:49:10.231 Ascend MSC: OUT: MODE,1 $ 12-Dec-2018 19:49:09.915 Ascend Vel PID Values 0.050000 0.010000 0.011069 -0.321288 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:09.915 Ascend SBE41 Message 7.41, 22.3214, 34.1943 7.410000 8.823827 -0.092754 0.010000 0.170000 0.044946 1.000000 $ 12-Dec-2018 19:49:10.881 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.410000 155.046247 27.775000 193.000000 $ 12-Dec-2018 19:49:11.134 Ascend MSC: RX: ACK,MODE,1 $ 12-Dec-2018 19:49:10.991 Ascend Vel PID Values 0.050000 -0.010000 -0.009932 -0.021001 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:10.991 Ascend SBE41 Message 7.42, 22.3219, 34.1941 7.420000 8.688979 -0.080974 -0.010000 0.000000 0.041952 1.000000 $ 12-Dec-2018 19:49:11.783 Ascend PTH Message 799.837891 24.016667 54.733795 25.008154 $ 12-Dec-2018 19:49:11.986 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.420000 155.039094 28.975000 174.000000 $ 12-Dec-2018 19:49:11.984 Ascend Vel PID Values 0.050000 0.020000 0.019900 0.029832 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:11.984 Ascend SBE41 Message 7.40, 22.3216, 34.1946 7.400000 8.400547 -0.043521 0.020000 0.005000 0.041256 1.000000 $ 12-Dec-2018 19:49:12.678 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.400000 155.039899 28.975000 174.000000 $ 12-Dec-2018 19:49:13.134 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:49:12.911 Ascend Vel PID Values 0.050000 0.070000 0.069834 0.049933 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:12.911 Ascend SBE41 Message 7.33, 22.3218, 34.1944 7.330000 8.016506 0.017362 0.070000 0.045000 0.042883 1.000000 $ 12-Dec-2018 19:49:13.782 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.330000 155.028522 28.975000 174.000000 $ 12-Dec-2018 19:49:13.909 Ascend Vel PID Values 0.050000 0.070000 0.069999 0.000166 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:13.909 Ascend SBE41 Message 7.26, 22.3226, 34.1943 7.260000 7.682141 0.084909 0.070000 0.070000 0.046026 1.000000 $ 12-Dec-2018 19:49:14.682 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.260000 155.032992 28.975000 174.000000 $ 12-Dec-2018 19:49:15.134 Ascend MSC: OUT: TS $ 12-Dec-2018 19:49:14.909 Ascend Vel PID Values 0.050000 0.040000 0.040100 -0.029899 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:14.909 Ascend SBE41 Message 7.22, 22.3221, 34.1950 7.220000 7.490284 0.138138 0.040000 0.055000 0.049768 1.000000 $ 12-Dec-2018 19:49:15.588 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:49:15.795 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.220000 155.054942 28.975000 174.000000 $ 12-Dec-2018 19:49:15.908 Ascend Vel PID Values 0.050000 -0.830000 -0.827105 -0.867205 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:15.908 Ascend SBE41 Message 8.05, 22.3227, 34.1945 8.050000 7.411992 0.168611 -0.830000 -0.395000 0.053525 1.000000 $ 12-Dec-2018 19:49:16.681 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.050000 155.020282 28.975000 174.000000 $ 12-Dec-2018 19:49:16.905 Ascend Vel PID Values 0.050000 -0.040000 -0.042624 0.784481 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:16.905 Ascend SBE41 Message 8.09, 22.3228, 34.1947 8.090000 7.373476 0.181842 -0.040000 -0.435000 0.056944 1.000000 $ 12-Dec-2018 19:49:17.682 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.090000 155.050866 28.975000 174.000000 $ 12-Dec-2018 19:49:17.905 Ascend Vel PID Values 0.050000 0.000000 -0.000137 0.042487 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:17.905 Ascend SBE41 Message 8.09, 22.3231, 34.1946 8.090000 7.352930 0.181965 0.000000 -0.020000 0.059514 1.000000 $ 12-Dec-2018 19:49:18.681 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.090000 155.046798 28.975000 174.000000 $ 12-Dec-2018 19:49:18.903 Ascend Vel PID Values 0.050000 -0.020000 -0.019933 -0.019796 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:18.903 Ascend SBE41 Message 8.11, 22.3234, 34.1948 8.110000 7.396943 0.159814 -0.020000 -0.010000 0.060610 1.000000 $ 12-Dec-2018 19:49:19.681 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.110000 155.044049 28.975000 174.000000 $ 12-Dec-2018 19:49:19.902 Ascend Vel PID Values 0.050000 0.020000 0.019867 0.039800 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:19.902 Ascend SBE41 Message 8.09, 22.3238, 34.1944 8.090000 7.550626 0.105116 0.020000 0.000000 0.059830 1.000000 $ 12-Dec-2018 19:49:20.681 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.090000 155.038640 28.975000 174.000000 $ 12-Dec-2018 19:49:20.902 Ascend Vel PID Values 0.050000 -0.010000 -0.009901 -0.029767 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:20.902 Ascend SBE41 Message 8.10, 22.3242, 34.1944 8.100000 7.774136 0.029973 -0.010000 0.005000 0.057255 1.000000 $ 12-Dec-2018 19:49:21.681 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.100000 155.040331 28.975000 174.000000 $ 12-Dec-2018 19:49:21.901 Ascend Vel PID Values 0.050000 0.080000 0.079701 0.089601 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:21.901 Ascend SBE41 Message 8.02, 22.3249, 34.1942 8.020000 7.964588 -0.034939 0.080000 0.035000 0.053405 1.000000 $ 12-Dec-2018 19:49:22.479 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:49:22.783 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 8.020000 155.045144 28.975000 174.000000 $ 12-Dec-2018 19:49:22.901 Ascend Vel PID Values 0.050000 1.160000 1.156406 1.076705 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:22.901 Ascend SBE41 Message 6.86, 22.3246, 34.1951 6.860000 8.063237 -0.070884 1.160000 0.620000 0.049030 1.000000 $ 12-Dec-2018 19:49:23.682 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.860000 155.047096 28.975000 174.000000 $ 12-Dec-2018 19:49:24.136 Ascend MSC: OUT: SL $ 12-Dec-2018 19:49:23.900 Ascend Vel PID Values 0.050000 0.250000 0.253022 -0.903384 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:23.900 Ascend SBE41 Message 6.61, 22.3255, 34.1928 6.610000 8.087344 -0.083566 0.250000 0.705000 0.044978 1.000000 $ 12-Dec-2018 19:49:24.877 Ascend Error in I2CPortBase.Execute $ 12-Dec-2018 19:49:24.979 Ascend 2485 Sample out of range $ 12-Dec-2018 19:49:24.983 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.610000 250.000000 28.975000 174.000000 $ 12-Dec-2018 19:49:25.194 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0579513 $ 12-Dec-2018 19:49:25.297 Ascend MSC: RX: 0x3FA4,A,01/31/2012 02:14:27,0,-1.00,-1.0000,-1.0000,232,147,1,65,23.63,56.30,11.576,5.228e-01,10490.00,2218.00,1204.83,15.18,-20.40,-192.17,3.408e-02,17,87,482D46C7448541CD38C3651E61A05F235D965CE25CD15DD45FB6622E658A694F6E32734678BD7ED3848089F78F0D933A95FD97799729957692348D9B881381957B4674D26EDD693D641E5FAB5BB15868558D532351224FAD4EA64DED4D7B4D77,6623.8 $ 12-Dec-2018 19:49:25.309 Ascend MSC: Data: 0x3FA4,A,01/31/2012 02:14:27,0,-1.00,-1.0000,-1.0000,232,147,1,65,23.63,56.30,11.576,5.228e-01,10490.00,2218.00,1204.83,15.18,-20.40,-192.17,3.408e-02,17,87,482D46C7448541CD38C3651E61A05F235D965CE25CD15DD45FB6622E658A694F6E32734678BD7ED3848089F78F0D933A95FD97799729957692348D9B881381957B4674D26EDD693D641E5FAB5BB15868558D532351224FAD4EA64DED4D7B4D77,6623.8 $ 12-Dec-2018 19:49:25.717 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.610000 155.051358 28.975000 174.000000 $ 12-Dec-2018 19:49:26.200 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:49:26.204 Ascend Starting pH sample $ 12-Dec-2018 19:49:26.403 Ascend MSC: OUT: W $ 12-Dec-2018 19:49:26.659 Ascend MSC: OUT: W $ 12-Dec-2018 19:49:26.761 Ascend MSC: RX: 88888888888888888888888888888888888888888888888888888888 $ 12-Dec-2018 19:49:25.546 Ascend Vel PID Values 0.050000 -0.010000 -0.009129 -0.262152 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:25.546 Ascend SBE41 Message 6.62, 22.3256, 34.1947 6.620000 8.049986 -0.083716 -0.010000 0.120000 0.041916 1.000000 $ 12-Dec-2018 19:49:25.897 Ascend Vel PID Values 0.050000 0.010000 0.009935 0.019064 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:25.897 Ascend SBE41 Message 6.61, 22.3258, 34.1949 6.610000 7.901773 -0.067921 0.010000 0.000000 0.040764 1.000000 $ 12-Dec-2018 19:49:27.551 Ascend MSC: RX: ACK $ 12-Dec-2018 19:49:27.556 Ascend MSC: Got ACK $ 12-Dec-2018 19:49:27.755 Ascend MSC: RX: ACK $ 12-Dec-2018 19:49:27.759 Ascend MSC: Got ACK $ 12-Dec-2018 19:49:26.901 Ascend Vel PID Values 0.050000 0.030000 0.029934 0.019999 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:26.901 Ascend SBE41 Message 6.58, 22.3259, 34.1951 6.580000 7.596215 -0.024673 0.030000 0.020000 0.041562 1.000000 $ 12-Dec-2018 19:49:28.505 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.580000 155.046418 28.975000 174.000000 $ 12-Dec-2018 19:49:28.616 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4160443 $ 12-Dec-2018 19:49:28.720 Ascend MSC: OUT: MODE,2 $ 12-Dec-2018 19:49:27.959 Ascend Vel PID Values 0.050000 0.060000 0.059900 0.029966 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:27.959 Ascend SBE41 Message 6.52, 22.3265, 34.1949 6.520000 7.199309 0.043440 0.060000 0.045000 0.044082 1.000000 $ 12-Dec-2018 19:49:28.895 Ascend Vel PID Values 0.050000 0.050000 0.050033 -0.009867 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:28.895 Ascend SBE41 Message 6.47, 22.3268, 34.1949 6.470000 6.863765 0.112608 0.050000 0.055000 0.047750 1.000000 $ 12-Dec-2018 19:49:29.735 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.470000 155.052327 28.975000 174.000000 $ 12-Dec-2018 19:49:29.846 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2242369 $ 12-Dec-2018 19:49:29.950 Ascend MSC: RX: ACK,MODE,2 $ 12-Dec-2018 19:49:29.949 Ascend Vel PID Values 0.050000 -0.560000 -0.557970 -0.608004 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:29.949 Ascend SBE41 Message 7.03, 22.3269, 34.1949 7.030000 6.677544 0.159225 -0.560000 -0.255000 0.051821 1.000000 $ 12-Dec-2018 19:49:30.600 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.030000 155.040510 28.975000 174.000000 $ 12-Dec-2018 19:49:30.950 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:49:30.892 Ascend Vel PID Values 0.050000 -0.330000 -0.330762 0.227208 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:30.892 Ascend SBE41 Message 7.36, 22.3275, 34.1946 7.360000 6.604468 0.180488 -0.330000 -0.445000 0.055590 1.000000 $ 12-Dec-2018 19:49:31.600 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.360000 155.042186 28.975000 174.000000 $ 12-Dec-2018 19:49:31.891 Ascend Vel PID Values 0.050000 0.040000 0.038767 0.369529 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:31.891 Ascend SBE41 Message 7.32, 22.3278, 34.1937 7.320000 6.582544 0.186183 0.040000 -0.145000 0.058372 1.000000 $ 12-Dec-2018 19:49:32.495 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.320000 155.053526 28.975000 174.000000 $ 12-Dec-2018 19:49:32.950 Ascend MSC: OUT: TS $ 12-Dec-2018 19:49:32.890 Ascend Vel PID Values 0.050000 0.010000 0.010098 -0.028669 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:32.890 Ascend SBE41 Message 7.31, 22.3276, 34.1950 7.310000 6.615533 0.177461 0.010000 0.025000 0.059608 1.000000 $ 12-Dec-2018 19:49:33.396 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:49:33.700 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.310000 155.053236 28.975000 174.000000 $ 12-Dec-2018 19:49:33.890 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.010065 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:33.890 Ascend SBE41 Message 7.31, 22.3284, 34.1945 7.310000 6.743109 0.143322 0.000000 0.005000 0.059045 1.000000 $ 12-Dec-2018 19:49:34.494 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.310000 155.069165 28.975000 174.000000 $ 12-Dec-2018 19:49:34.889 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010000 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:34.889 Ascend SBE41 Message 7.32, 22.3287, 34.1945 7.320000 6.950245 0.079891 -0.010000 -0.005000 0.056784 1.000000 $ 12-Dec-2018 19:49:35.494 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.320000 155.068547 28.975000 174.000000 $ 12-Dec-2018 19:49:35.888 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019901 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:35.888 Ascend SBE41 Message 7.31, 22.3283, 34.1951 7.310000 7.149866 0.006101 0.010000 0.000000 0.053264 1.000000 $ 12-Dec-2018 19:49:36.494 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.310000 155.051589 28.975000 174.000000 $ 12-Dec-2018 19:49:36.887 Ascend Vel PID Values 0.050000 0.200000 0.199367 0.189434 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:36.887 Ascend SBE41 Message 7.11, 22.3292, 34.1946 7.110000 7.268206 -0.050046 0.200000 0.105000 0.049240 1.000000 $ 12-Dec-2018 19:49:37.494 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.110000 155.037269 28.975000 174.000000 $ 12-Dec-2018 19:49:37.886 Ascend Vel PID Values 0.050000 1.070000 1.067104 0.867737 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:37.886 Ascend SBE41 Message 6.04, 22.3297, 34.1947 6.040000 7.307647 -0.077968 1.070000 0.635000 0.045635 1.000000 $ 12-Dec-2018 19:49:38.496 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.040000 155.061543 28.975000 174.000000 $ 12-Dec-2018 19:49:38.885 Ascend Vel PID Values 0.050000 0.150000 0.153057 -0.914047 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:38.885 Ascend SBE41 Message 5.89, 22.3295, 34.1953 5.890000 7.304455 -0.086617 0.150000 0.610000 0.043160 1.000000 $ 12-Dec-2018 19:49:39.497 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 5.890000 155.053139 28.975000 174.000000 $ 12-Dec-2018 19:49:39.957 Ascend ERROR: Missed PH message 8 $ 12-Dec-2018 19:49:40.063 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:49:40.067 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:49:40.669 Ascend Sending FLBB run command $ 12-Dec-2018 19:49:40.685 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:49:39.883 Ascend Vel PID Values 0.050000 0.000000 0.000504 -0.152553 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:39.883 Ascend SBE41 Message 5.89, 22.3297, 34.1953 5.890000 7.251834 -0.082813 0.000000 0.075000 0.042052 1.000000 $ 12-Dec-2018 19:49:40.888 Ascend Vel PID Values 0.050000 0.020000 0.019934 0.019430 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:40.888 Ascend SBE41 Message 5.87, 22.3305, 34.1950 5.870000 7.087806 -0.058433 0.020000 0.010000 0.042288 1.000000 $ 12-Dec-2018 19:49:41.576 Ascend Radiometer Message SATFI40287,-0.0051,0.0020,-0.0058,-0.2070 $ 12-Dec-2018 19:49:41.895 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.870000 155.039325 28.975000 174.000000 $ 12-Dec-2018 19:49:42.008 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0568368 $ 12-Dec-2018 19:49:41.760 Ascend Optode Message 4330,1532,263.066,22.788,29.106,29.036,36.146,7.109,535.9,464.3,101.0 $ 12-Dec-2018 19:49:41.763 Ascend Optode Message # $ 12-Dec-2018 19:49:41.882 Ascend Vel PID Values 0.050000 0.030000 0.029966 0.010032 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:41.882 Ascend SBE41 Message 5.84, 22.3308, 34.1951 5.840000 6.777158 -0.004225 0.030000 0.025000 0.043889 1.000000 $ 12-Dec-2018 19:49:42.582 Ascend FLBB Message /99/99,99:99:99,695,2305,700,4130,532 $ 12-Dec-2018 19:49:42.994 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.840000 155.050993 28.975000 174.000000 $ 12-Dec-2018 19:49:43.105 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0923705 $ 12-Dec-2018 19:49:42.880 Ascend Vel PID Values 0.050000 0.060000 0.059900 0.029934 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:42.880 Ascend SBE41 Message 5.78, 22.3304, 34.1957 5.780000 6.398324 0.068256 0.060000 0.045000 0.046791 1.000000 $ 12-Dec-2018 19:49:43.758 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.780000 155.060314 28.975000 174.000000 $ 12-Dec-2018 19:49:43.880 Ascend Vel PID Values 0.050000 0.030000 0.030100 -0.029800 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:43.880 Ascend SBE41 Message 5.75, 22.3312, 34.1952 5.750000 6.094158 0.130583 0.030000 0.045000 0.050434 1.000000 $ 12-Dec-2018 19:49:44.657 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.750000 155.057006 28.975000 174.000000 $ 12-Dec-2018 19:49:44.878 Ascend Vel PID Values 0.050000 -0.580000 -0.577970 -0.608070 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:44.878 Ascend SBE41 Message 6.33, 22.3315, 34.1950 6.330000 5.931345 0.165385 -0.580000 -0.275000 0.053874 1.000000 $ 12-Dec-2018 19:49:45.657 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.330000 155.062295 28.975000 174.000000 $ 12-Dec-2018 19:49:45.878 Ascend Vel PID Values 0.050000 -0.220000 -0.221195 0.356775 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:45.878 Ascend SBE41 Message 6.55, 22.3314, 34.1953 6.550000 5.866749 0.178275 -0.220000 -0.400000 0.056321 1.000000 $ 12-Dec-2018 19:49:46.657 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.550000 155.059032 28.975000 174.000000 $ 12-Dec-2018 19:49:47.112 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:49:46.877 Ascend Vel PID Values 0.050000 0.050000 0.049100 0.270295 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:46.877 Ascend SBE41 Message 6.50, 22.3315, 34.1955 6.500000 5.846998 0.180322 0.050000 -0.085000 0.057452 1.000000 $ 12-Dec-2018 19:49:47.759 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.500000 155.022830 28.975000 174.000000 $ 12-Dec-2018 19:49:47.876 Ascend Vel PID Values 0.050000 0.020000 0.020098 -0.029001 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:47.876 Ascend SBE41 Message 6.48, 22.3327, 34.1948 6.480000 5.882378 0.169416 0.020000 0.035000 0.057304 1.000000 $ 12-Dec-2018 19:49:48.657 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.480000 155.043557 28.975000 174.000000 $ 12-Dec-2018 19:49:49.112 Ascend MSC: OUT: SL $ 12-Dec-2018 19:49:48.875 Ascend Vel PID Values 0.050000 0.010000 0.010034 -0.010065 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:48.875 Ascend SBE41 Message 6.47, 22.3327, 34.1948 6.470000 6.007604 0.133614 0.010000 0.015000 0.055888 1.000000 $ 12-Dec-2018 19:49:49.760 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.470000 155.055426 28.975000 174.000000 $ 12-Dec-2018 19:49:50.112 Ascend MSC: RX: 0x85E6,pH,01/31/2012 02:14:53,0,-1.00,-1.0000,-1.0000,260,147,0,23.65,56.28,11.744,4.660e-02,7.1234,0.000,-0.971769,0.000581,-0.960662,0.000584,+1.502e-08,+2.164e-08 $ 12-Dec-2018 19:49:50.121 Ascend MSC: Data: 0x85E6,pH,01/31/2012 02:14:53,0,-1.00,-1.0000,-1.0000,260,147,0,23.65,56.28,11.744,4.660e-02,7.1234,0.000,-0.971769,0.000581,-0.960662,0.000584,+1.502e-08,+2.164e-08 $ 12-Dec-2018 19:49:49.873 Ascend Vel PID Values 0.050000 -0.010000 -0.009934 -0.019967 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:49.873 Ascend SBE41 Message 6.48, 22.3327, 34.1945 6.480000 6.198970 0.071506 -0.010000 0.000000 0.053311 1.000000 $ 12-Dec-2018 19:49:50.869 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.480000 155.046165 28.975000 174.000000 $ 12-Dec-2018 19:49:51.111 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:49:51.116 Ascend MSC: OUT: SLP $ 12-Dec-2018 19:49:50.979 Ascend Vel PID Values 0.050000 0.010000 0.009934 0.019867 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:50.979 Ascend SBE41 Message 6.47, 22.3334, 34.1950 6.470000 6.370780 0.003393 0.010000 0.000000 0.050098 1.000000 $ 12-Dec-2018 19:49:51.862 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.470000 155.049860 28.975000 174.000000 $ 12-Dec-2018 19:49:52.112 Ascend MSC: RX: ACK,SLP $ 12-Dec-2018 19:49:51.971 Ascend Vel PID Values 0.050000 0.010000 0.010000 0.000066 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:51.971 Ascend SBE41 Message 6.46, 22.3332, 34.1954 6.460000 6.461338 -0.045437 0.010000 0.010000 0.047232 1.000000 $ 12-Dec-2018 19:49:52.759 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 6.460000 155.056752 28.975000 174.000000 $ 12-Dec-2018 19:49:52.871 Ascend Vel PID Values 0.050000 0.470000 0.468469 0.458470 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:52.871 Ascend SBE41 Message 5.99, 22.3342, 34.1951 5.990000 6.482967 -0.068260 0.470000 0.240000 0.045438 1.000000 $ 12-Dec-2018 19:49:53.658 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.990000 155.064508 28.975000 174.000000 $ 12-Dec-2018 19:49:53.870 Ascend Vel PID Values 0.050000 0.780000 0.778966 0.310496 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:53.870 Ascend SBE41 Message 5.21, 22.3342, 34.1955 5.210000 6.477759 -0.075607 0.780000 0.625000 0.044663 1.000000 $ 12-Dec-2018 19:49:54.660 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.210000 155.079246 28.975000 174.000000 $ 12-Dec-2018 19:49:54.869 Ascend Vel PID Values 0.050000 0.080000 0.082328 -0.696638 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:54.869 Ascend SBE41 Message 5.13, 22.3348, 34.1937 5.130000 6.456618 -0.075425 0.080000 0.430000 0.044479 1.000000 $ 12-Dec-2018 19:49:55.660 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.130000 155.062154 28.975000 174.000000 $ 12-Dec-2018 19:49:55.868 Ascend Vel PID Values 0.050000 -0.020000 -0.019663 -0.101991 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:55.868 Ascend SBE41 Message 5.15, 22.3348, 34.1955 5.150000 6.379545 -0.061500 -0.020000 0.030000 0.044685 1.000000 $ 12-Dec-2018 19:49:56.659 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.150000 155.042030 28.975000 174.000000 $ 12-Dec-2018 19:49:56.866 Ascend Vel PID Values 0.050000 0.020000 0.019867 0.039531 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:56.866 Ascend SBE41 Message 5.13, 22.3347, 34.1959 5.130000 6.185370 -0.021990 0.020000 0.000000 0.045559 1.000000 $ 12-Dec-2018 19:49:57.660 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.130000 155.072182 28.975000 174.000000 $ 12-Dec-2018 19:49:57.866 Ascend Vel PID Values 0.050000 0.040000 0.039933 0.020066 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:57.866 Ascend SBE41 Message 5.09, 22.3351, 34.1958 5.090000 5.869600 0.040729 0.040000 0.030000 0.047446 1.000000 $ 12-Dec-2018 19:49:58.660 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.090000 155.064896 28.975000 174.000000 $ 12-Dec-2018 19:49:58.865 Ascend Vel PID Values 0.050000 0.040000 0.040000 0.000067 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:58.865 Ascend SBE41 Message 5.05, 22.3354, 34.1960 5.050000 5.529224 0.104078 0.040000 0.040000 0.050134 1.000000 $ 12-Dec-2018 19:49:59.663 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.050000 155.040555 28.975000 174.000000 $ 12-Dec-2018 19:49:59.864 Ascend Vel PID Values 0.050000 0.050000 0.049967 0.009967 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:49:59.864 Ascend SBE41 Message 5.00, 22.3364, 34.1945 5.000000 5.284264 0.145596 0.050000 0.045000 0.052777 1.000000 $ 12-Dec-2018 19:50:00.661 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.000000 155.047089 28.975000 174.000000 $ 12-Dec-2018 19:50:00.863 Ascend Vel PID Values 0.050000 0.020000 0.020100 -0.029867 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:00.863 Ascend SBE41 Message 4.98, 22.3362, 34.1957 4.980000 5.165420 0.162999 0.020000 0.035000 0.054565 1.000000 $ 12-Dec-2018 19:50:01.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.980000 155.082867 28.975000 174.000000 $ 12-Dec-2018 19:50:01.862 Ascend Vel PID Values 0.050000 -0.630000 -0.627837 -0.647937 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:01.862 Ascend SBE41 Message 5.61, 22.3365, 34.1956 5.610000 5.117719 0.168271 -0.630000 -0.305000 0.055301 1.000000 $ 12-Dec-2018 19:50:02.661 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.610000 155.039355 28.975000 174.000000 $ 12-Dec-2018 19:50:02.861 Ascend Vel PID Values 0.050000 -0.080000 -0.081827 0.546010 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:02.861 Ascend SBE41 Message 5.69, 22.3369, 34.1954 5.690000 5.086729 0.169480 -0.080000 -0.355000 0.055233 1.000000 $ 12-Dec-2018 19:50:03.661 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.690000 155.066170 28.975000 174.000000 $ 12-Dec-2018 19:50:03.859 Ascend Vel PID Values 0.050000 0.040000 0.039598 0.121424 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:03.859 Ascend SBE41 Message 5.65, 22.3371, 34.1956 5.650000 5.069586 0.162041 0.040000 -0.020000 0.054572 1.000000 $ 12-Dec-2018 19:50:04.662 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.650000 155.060403 28.975000 174.000000 $ 12-Dec-2018 19:50:04.859 Ascend Vel PID Values 0.050000 0.030000 0.030033 -0.009565 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:04.859 Ascend SBE41 Message 5.62, 22.3376, 34.1955 5.620000 5.107014 0.133372 0.030000 0.035000 0.053290 1.000000 $ 12-Dec-2018 19:50:05.662 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.620000 155.074619 28.975000 174.000000 $ 12-Dec-2018 19:50:05.858 Ascend Vel PID Values 0.050000 0.010000 0.010066 -0.019966 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:05.858 Ascend SBE41 Message 5.61, 22.3380, 34.1954 5.610000 5.231936 0.078860 0.010000 0.020000 0.051628 1.000000 $ 12-Dec-2018 19:50:06.663 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.610000 155.052289 28.975000 174.000000 $ 12-Dec-2018 19:50:06.857 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.010033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:06.857 Ascend SBE41 Message 5.61, 22.3382, 34.1955 5.610000 5.409991 0.014745 0.000000 0.005000 0.049990 1.000000 $ 12-Dec-2018 19:50:07.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.610000 155.061983 28.975000 174.000000 $ 12-Dec-2018 19:50:07.855 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:07.855 Ascend SBE41 Message 5.61, 22.3383, 34.1957 5.610000 5.556112 -0.033625 0.000000 0.000000 0.048922 1.000000 $ 12-Dec-2018 19:50:08.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.610000 155.061543 28.975000 174.000000 $ 12-Dec-2018 19:50:08.854 Ascend Vel PID Values 0.050000 0.000000 0.000000 -0.000000 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:08.854 Ascend SBE41 Message 5.61, 22.3383, 34.1958 5.610000 5.621608 -0.056438 0.000000 0.000000 0.048611 1.000000 $ 12-Dec-2018 19:50:09.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.610000 155.068219 28.975000 174.000000 $ 12-Dec-2018 19:50:09.854 Ascend Vel PID Values 0.050000 0.380000 0.378736 0.378736 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:09.854 Ascend SBE41 Message 5.23, 22.3385, 34.1961 5.230000 5.628358 -0.063188 0.380000 0.190000 0.048744 1.000000 $ 12-Dec-2018 19:50:10.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.230000 155.078061 28.975000 174.000000 $ 12-Dec-2018 19:50:10.853 Ascend Vel PID Values 0.050000 0.830000 0.828500 0.449765 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:10.853 Ascend SBE41 Message 4.40, 22.3397, 34.1958 4.400000 5.617602 -0.065692 0.830000 0.605000 0.049014 1.000000 $ 12-Dec-2018 19:50:11.666 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.400000 155.062035 28.975000 174.000000 $ 12-Dec-2018 19:50:11.851 Ascend Vel PID Values 0.050000 0.110000 0.112394 -0.716107 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:11.851 Ascend SBE41 Message 4.29, 22.3400, 34.1958 4.290000 5.598136 -0.065393 0.110000 0.470000 0.049256 1.000000 $ 12-Dec-2018 19:50:12.668 Ascend PTH Message 801.208252 24.000000 54.787201 25.008154 $ 12-Dec-2018 19:50:12.871 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.290000 155.057587 29.100000 163.000000 $ 12-Dec-2018 19:50:12.870 Ascend Vel PID Values 0.050000 0.000000 0.000370 -0.112024 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:12.870 Ascend SBE41 Message 4.29, 22.3406, 34.1956 4.290000 5.531740 -0.052536 0.000000 0.055000 0.049424 1.000000 $ 12-Dec-2018 19:50:13.663 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.290000 155.056082 29.100000 163.000000 $ 12-Dec-2018 19:50:13.849 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009597 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:13.849 Ascend SBE41 Message 4.28, 22.3404, 34.1961 4.280000 5.355195 -0.015246 0.010000 0.005000 0.049548 1.000000 $ 12-Dec-2018 19:50:14.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.280000 155.066185 29.100000 163.000000 $ 12-Dec-2018 19:50:14.848 Ascend Vel PID Values 0.050000 0.030000 0.029934 0.019967 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:14.848 Ascend SBE41 Message 4.25, 22.3406, 34.1960 4.250000 5.052811 0.044168 0.030000 0.020000 0.049721 1.000000 $ 12-Dec-2018 19:50:15.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.250000 155.065827 29.100000 163.000000 $ 12-Dec-2018 19:50:15.847 Ascend Vel PID Values 0.050000 0.040000 0.039967 0.010033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:15.847 Ascend SBE41 Message 4.21, 22.3410, 34.1959 4.210000 4.711230 0.104486 0.040000 0.035000 0.050019 1.000000 $ 12-Dec-2018 19:50:16.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.210000 155.070052 29.100000 163.000000 $ 12-Dec-2018 19:50:16.846 Ascend Vel PID Values 0.050000 0.030000 0.030033 -0.009933 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:16.846 Ascend SBE41 Message 4.18, 22.3414, 34.1959 4.180000 4.453630 0.144466 0.030000 0.035000 0.050347 1.000000 $ 12-Dec-2018 19:50:17.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.180000 155.056000 29.100000 163.000000 $ 12-Dec-2018 19:50:17.845 Ascend Vel PID Values 0.050000 0.040000 0.039967 0.009933 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:17.845 Ascend SBE41 Message 4.14, 22.3412, 34.1963 4.140000 4.323091 0.161476 0.040000 0.035000 0.050473 1.000000 $ 12-Dec-2018 19:50:18.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.140000 155.072980 29.100000 163.000000 $ 12-Dec-2018 19:50:18.845 Ascend Vel PID Values 0.050000 -0.330000 -0.328769 -0.368735 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:18.845 Ascend SBE41 Message 4.47, 22.3415, 34.1962 4.470000 4.272122 0.166469 -0.330000 -0.145000 0.050236 1.000000 $ 12-Dec-2018 19:50:19.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.470000 155.068897 29.100000 163.000000 $ 12-Dec-2018 19:50:19.843 Ascend Vel PID Values 0.050000 -0.340000 -0.339965 -0.011196 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:19.843 Ascend SBE41 Message 4.81, 22.3416, 34.1962 4.810000 4.243715 0.167569 -0.340000 -0.335000 0.049736 1.000000 $ 12-Dec-2018 19:50:20.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.810000 155.071937 29.100000 163.000000 $ 12-Dec-2018 19:50:20.842 Ascend Vel PID Values 0.050000 0.020000 0.018802 0.358767 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:20.842 Ascend SBE41 Message 4.79, 22.3427, 34.1957 4.790000 4.223816 0.161793 0.020000 -0.160000 0.049376 1.000000 $ 12-Dec-2018 19:50:21.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.790000 155.086115 29.100000 163.000000 $ 12-Dec-2018 19:50:21.842 Ascend Vel PID Values 0.050000 0.030000 0.029964 0.011162 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:21.842 Ascend SBE41 Message 4.76, 22.3429, 34.1958 4.760000 4.238997 0.138053 0.030000 0.025000 0.049619 1.000000 $ 12-Dec-2018 19:50:22.663 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.760000 155.071490 29.100000 163.000000 $ 12-Dec-2018 19:50:22.840 Ascend Vel PID Values 0.050000 0.020000 0.020034 -0.009931 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:22.840 Ascend SBE41 Message 4.74, 22.3440, 34.1953 4.740000 4.324898 0.090019 0.020000 0.025000 0.050531 1.000000 $ 12-Dec-2018 19:50:23.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.740000 155.071698 29.100000 163.000000 $ 12-Dec-2018 19:50:23.839 Ascend Vel PID Values 0.050000 -0.010000 -0.009900 -0.029934 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:23.839 Ascend SBE41 Message 4.75, 22.3433, 34.1960 4.750000 4.476421 0.029038 -0.010000 0.005000 0.051670 1.000000 $ 12-Dec-2018 19:50:24.665 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.750000 155.072324 29.100000 163.000000 $ 12-Dec-2018 19:50:24.838 Ascend Vel PID Values 0.050000 0.020000 0.019900 0.029801 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:24.838 Ascend SBE41 Message 4.73, 22.3434, 34.1963 4.730000 4.631446 -0.021992 0.020000 0.005000 0.052565 1.000000 $ 12-Dec-2018 19:50:25.664 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.730000 155.094817 29.100000 163.000000 $ 12-Dec-2018 19:50:25.837 Ascend Vel PID Values 0.050000 -0.010000 -0.009900 -0.029800 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:25.837 Ascend SBE41 Message 4.74, 22.3439, 34.1960 4.740000 4.726772 -0.049936 -0.010000 0.005000 0.053116 1.000000 $ 12-Dec-2018 19:50:26.685 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.740000 155.054860 29.100000 163.000000 $ 12-Dec-2018 19:50:26.836 Ascend Vel PID Values 0.050000 0.110000 0.109600 0.119501 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:26.836 Ascend SBE41 Message 4.63, 22.3439, 34.1958 4.630000 4.755581 -0.059819 0.110000 0.050000 0.053422 1.000000 $ 12-Dec-2018 19:50:27.666 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.630000 155.066274 29.100000 163.000000 $ 12-Dec-2018 19:50:27.836 Ascend Vel PID Values 0.050000 0.830000 0.827603 0.718003 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:27.836 Ascend SBE41 Message 3.80, 22.3446, 34.1961 3.800000 4.751761 -0.062867 0.830000 0.470000 0.053401 1.000000 $ 12-Dec-2018 19:50:28.666 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 3.800000 155.080058 29.100000 163.000000 $ 12-Dec-2018 19:50:29.130 Ascend ERROR: Missed NO3 message 8 $ 12-Dec-2018 19:50:29.234 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:50:29.238 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:50:29.841 Ascend Sending FLBB run command $ 12-Dec-2018 19:50:29.958 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:50:28.834 Ascend Vel PID Values 0.050000 0.350000 0.351593 -0.476010 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:28.834 Ascend SBE41 Message 3.45, 22.3448, 34.1964 3.450000 4.738442 -0.063675 0.350000 0.590000 0.052733 1.000000 $ 12-Dec-2018 19:50:29.832 Ascend Vel PID Values 0.050000 0.010000 0.011134 -0.340459 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:29.832 Ascend SBE41 Message 3.44, 22.3447, 34.1966 3.440000 4.698048 -0.056787 0.010000 0.180000 0.051237 1.000000 $ 12-Dec-2018 19:50:30.650 Ascend Radiometer Message SATFI40287,-0.0046,0.0024,-0.0075,-0.2037 $ 12-Dec-2018 19:50:30.862 Ascend Vel PID Values 0.050000 0.000000 0.000035 -0.011099 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:30.862 Ascend SBE41 Message 3.44, 22.3452, 34.1965 3.440000 4.573752 -0.030781 0.000000 0.005000 0.049227 1.000000 $ 12-Dec-2018 19:50:31.316 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.440000 155.064411 29.100000 163.000000 $ 12-Dec-2018 19:50:31.428 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3071629 $ 12-Dec-2018 19:50:31.434 Ascend Starting ISUS sample $ 12-Dec-2018 19:50:31.634 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 12-Dec-2018 19:50:31.737 Ascend MSC: OUT: W $ 12-Dec-2018 19:50:31.992 Ascend MSC: OUT: W $ 12-Dec-2018 19:50:30.931 Ascend Optode Message 4330,1532,262.890,22.803,29.108,29.038,36.148,7.110,535.8,464.2,100.5 $ 12-Dec-2018 19:50:30.935 Ascend Optode Message # $ 12-Dec-2018 19:50:32.323 Ascend FLBB Message /99/99,99:99:99,695,2310,700,4130,532 $ 12-Dec-2018 19:50:31.840 Ascend Vel PID Values 0.050000 0.020000 0.019933 0.019898 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:31.840 Ascend SBE41 Message 3.42, 22.3458, 34.1963 3.420000 4.321413 0.019165 0.020000 0.010000 0.047467 1.000000 $ 12-Dec-2018 19:50:32.778 Ascend MSC: RX: $ 12-Dec-2018 19:50:32.880 Ascend MSC: RX: $ 12-Dec-2018 19:50:32.885 Ascend MSC: RX: ACK $ 12-Dec-2018 19:50:32.986 Ascend MSC: Got ACK $ 12-Dec-2018 19:50:33.387 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.420000 155.082271 29.100000 163.000000 $ 12-Dec-2018 19:50:33.500 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0657962 $ 12-Dec-2018 19:50:32.880 Ascend Vel PID Values 0.050000 0.030000 0.029967 0.010033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:32.880 Ascend SBE41 Message 3.39, 22.3454, 34.1969 3.390000 3.986264 0.079786 0.030000 0.025000 0.046455 1.000000 $ 12-Dec-2018 19:50:33.832 Ascend Vel PID Values 0.050000 0.030000 0.030000 0.000034 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:33.832 Ascend SBE41 Message 3.36, 22.3463, 34.1965 3.360000 3.689696 0.128266 0.030000 0.030000 0.046088 1.000000 $ 12-Dec-2018 19:50:34.492 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.360000 155.094907 29.100000 163.000000 $ 12-Dec-2018 19:50:34.603 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0979252 $ 12-Dec-2018 19:50:34.709 Ascend MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 12-Dec-2018 19:50:35.034 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.360000 155.088633 29.100000 163.000000 $ 12-Dec-2018 19:50:34.826 Ascend Vel PID Values 0.050000 0.040000 0.039967 0.009967 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:34.826 Ascend SBE41 Message 3.32, 22.3467, 34.1963 3.320000 3.514330 0.153546 0.040000 0.035000 0.045920 1.000000 $ 12-Dec-2018 19:50:35.955 Ascend MSC: RX: NAK,CTD,EConvertErr: 0 $ 12-Dec-2018 19:50:36.057 Ascend MSC: EConvertErr: 0 $ 12-Dec-2018 19:50:35.839 Ascend Vel PID Values 0.050000 0.030000 0.030033 -0.009933 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:35.839 Ascend SBE41 Message 3.29, 22.3474, 34.1947 3.290000 3.442349 0.162002 0.030000 0.035000 0.045760 1.000000 $ 12-Dec-2018 19:50:36.705 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.290000 155.080095 29.100000 163.000000 $ 12-Dec-2018 19:50:36.817 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2074080 $ 12-Dec-2018 19:50:36.920 Ascend Vel PID Values 0.050000 -0.060000 -0.059700 -0.089734 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:36.920 Ascend SBE41 Message 3.35, 22.3465, 34.1970 3.350000 3.412286 0.164078 -0.060000 -0.015000 0.045899 1.000000 $ 12-Dec-2018 19:50:37.467 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.350000 155.077316 29.100000 163.000000 $ 12-Dec-2018 19:50:37.823 Ascend MSC: OUT: W $ 12-Dec-2018 19:50:38.176 Ascend MSC: OUT: W $ 12-Dec-2018 19:50:37.827 Ascend Vel PID Values 0.050000 -0.450000 -0.448702 -0.389001 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:37.827 Ascend SBE41 Message 3.80, 22.3480, 34.1960 3.800000 3.386523 0.162249 -0.450000 -0.255000 0.046833 1.000000 $ 12-Dec-2018 19:50:38.621 Ascend MSC: RX: ACK $ 12-Dec-2018 19:50:38.625 Ascend MSC: Got ACK $ 12-Dec-2018 19:50:38.826 Ascend MSC: RX: ACK $ 12-Dec-2018 19:50:38.927 Ascend MSC: Got ACK $ 12-Dec-2018 19:50:38.825 Ascend Vel PID Values 0.050000 -0.020000 -0.021429 0.427273 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:38.825 Ascend SBE41 Message 3.82, 22.3477, 34.1963 3.820000 3.360227 0.150097 -0.020000 -0.235000 0.048709 1.000000 $ 12-Dec-2018 19:50:39.573 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.820000 155.059479 29.100000 163.000000 $ 12-Dec-2018 19:50:39.684 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8616802 $ 12-Dec-2018 19:50:39.789 Ascend MSC: OUT: MODE,1 $ 12-Dec-2018 19:50:39.891 Ascend Vel PID Values 0.050000 0.040000 0.039798 0.061227 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:39.891 Ascend SBE41 Message 3.78, 22.3480, 34.1963 3.780000 3.351097 0.119996 0.040000 0.010000 0.051143 1.000000 $ 12-Dec-2018 19:50:40.439 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.780000 155.072562 29.100000 163.000000 $ 12-Dec-2018 19:50:40.692 Ascend MSC: RX: ACK,MODE,1 $ 12-Dec-2018 19:50:40.997 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.780000 155.080341 29.100000 163.000000 $ 12-Dec-2018 19:50:40.822 Ascend Vel PID Values 0.050000 0.000000 0.000133 -0.039665 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:40.822 Ascend SBE41 Message 3.78, 22.3481, 34.1964 3.780000 3.391599 0.073535 0.000000 0.020000 0.053534 1.000000 $ 12-Dec-2018 19:50:41.919 Ascend Vel PID Values 0.050000 0.010000 0.009967 0.009834 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:41.919 Ascend SBE41 Message 3.77, 22.3483, 34.1966 3.770000 3.497366 0.023787 0.010000 0.005000 0.055368 1.000000 $ 12-Dec-2018 19:50:42.580 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.770000 155.074470 29.100000 163.000000 $ 12-Dec-2018 19:50:42.693 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0027066 $ 12-Dec-2018 19:50:42.797 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:50:42.898 Ascend Vel PID Values 0.050000 0.000000 0.000033 -0.009934 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:42.898 Ascend SBE41 Message 3.77, 22.3491, 34.1961 3.770000 3.632444 -0.014601 0.000000 0.005000 0.056526 1.000000 $ 12-Dec-2018 19:50:43.449 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.770000 155.075930 29.100000 163.000000 $ 12-Dec-2018 19:50:43.901 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.770000 155.082807 29.100000 163.000000 $ 12-Dec-2018 19:50:44.700 Ascend MSC: OUT: TS $ 12-Dec-2018 19:50:43.818 Ascend Vel PID Values 0.050000 -0.010000 -0.009967 -0.010000 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:43.818 Ascend SBE41 Message 3.78, 22.3487, 34.1966 3.780000 3.734161 -0.036091 -0.010000 -0.005000 0.057127 1.000000 $ 12-Dec-2018 19:50:44.822 Ascend Vel PID Values 0.050000 0.010000 0.009933 0.019900 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:44.822 Ascend SBE41 Message 3.77, 22.3498, 34.1960 3.770000 3.776091 -0.045010 0.010000 0.000000 0.057179 1.000000 $ 12-Dec-2018 19:50:45.490 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:50:45.795 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.770000 155.077249 29.100000 163.000000 $ 12-Dec-2018 19:50:45.907 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2074399 $ 12-Dec-2018 19:50:45.905 Ascend Vel PID Values 0.050000 0.120000 0.119634 0.109700 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:45.905 Ascend SBE41 Message 3.65, 22.3498, 34.1963 3.650000 3.780247 -0.048721 0.120000 0.065000 0.056460 1.000000 $ 12-Dec-2018 19:50:46.556 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 3.650000 155.068234 29.100000 163.000000 $ 12-Dec-2018 19:50:46.815 Ascend Vel PID Values 0.050000 0.760000 0.757870 0.638236 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:46.815 Ascend SBE41 Message 2.89, 22.3502, 34.1963 2.890000 3.775481 -0.051383 0.760000 0.440000 0.054831 1.000000 $ 12-Dec-2018 19:50:47.459 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.890000 155.092560 29.100000 163.000000 $ 12-Dec-2018 19:50:47.815 Ascend Vel PID Values 0.050000 0.390000 0.391228 -0.366642 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:47.815 Ascend SBE41 Message 2.50, 22.3504, 34.1967 2.500000 3.767721 -0.051542 0.390000 0.575000 0.052362 1.000000 $ 12-Dec-2018 19:50:48.459 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.500000 155.081548 29.100000 163.000000 $ 12-Dec-2018 19:50:48.814 Ascend Vel PID Values 0.050000 0.000000 0.001300 -0.389928 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:48.814 Ascend SBE41 Message 2.50, 22.3504, 34.1967 2.500000 3.731714 -0.042067 0.000000 0.195000 0.049436 1.000000 $ 12-Dec-2018 19:50:49.460 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.500000 155.084476 29.100000 163.000000 $ 12-Dec-2018 19:50:49.813 Ascend Vel PID Values 0.050000 -0.010000 -0.009965 -0.011264 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:49.813 Ascend SBE41 Message 2.51, 22.3507, 34.1968 2.510000 3.611941 -0.014171 -0.010000 -0.005000 0.046565 1.000000 $ 12-Dec-2018 19:50:50.460 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.510000 155.090787 29.100000 163.000000 $ 12-Dec-2018 19:50:50.812 Ascend Vel PID Values 0.050000 0.020000 0.019900 0.029865 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:50.812 Ascend SBE41 Message 2.49, 22.3510, 34.1967 2.490000 3.366881 0.032835 0.020000 0.005000 0.044253 1.000000 $ 12-Dec-2018 19:50:51.459 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.490000 155.080840 29.100000 163.000000 $ 12-Dec-2018 19:50:51.914 Ascend MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:50:51.810 Ascend Vel PID Values 0.050000 0.020000 0.020000 0.000100 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:51.810 Ascend SBE41 Message 2.47, 22.3509, 34.1971 2.470000 3.040280 0.085804 0.020000 0.020000 0.042786 1.000000 $ 12-Dec-2018 19:50:52.561 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.470000 155.063950 29.100000 163.000000 $ 12-Dec-2018 19:50:52.810 Ascend Vel PID Values 0.050000 0.030000 0.029967 0.009967 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:52.810 Ascend SBE41 Message 2.44, 22.3517, 34.1966 2.440000 2.749806 0.126929 0.030000 0.025000 0.042155 1.000000 $ 12-Dec-2018 19:50:53.459 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.440000 155.070215 29.100000 163.000000 $ 12-Dec-2018 19:50:53.914 Ascend MSC: OUT: SL $ 12-Dec-2018 19:50:53.809 Ascend Vel PID Values 0.050000 0.030000 0.030000 0.000033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:53.809 Ascend SBE41 Message 2.41, 22.3518, 34.1969 2.410000 2.578016 0.148719 0.030000 0.030000 0.042310 1.000000 $ 12-Dec-2018 19:50:54.771 Ascend Error in I2CPortBase.Execute $ 12-Dec-2018 19:50:54.776 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.410000 155.070215 29.100000 163.000000 $ 12-Dec-2018 19:50:54.986 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0721390 $ 12-Dec-2018 19:50:55.291 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.410000 155.085929 29.100000 163.000000 $ 12-Dec-2018 19:50:55.993 Ascend MSC: RX: 0x5451,A,01/31/2012 02:15:56,0,-1.00,-1.0000,-1.0000,233,147,1,65,23.76,56.06,11.576,5.230e-01,10494.00,2224.00,1208.55,13.17,-205F0865CA6C3771A8758277AA783776F1747870DE6CFA68B564FD61865F0F5D905CD95CC95DB35FB66219656E69646DF372FF789E7EB4847A89E78EF3931495CD97649719954C91EE8D7287EE816D7B1A74A66EAE692263E85F825BAE5857557D52FD510E4F924EA04DD74D6D4D61,6620.2 $ 12-Dec-2018 19:50:56.004 Ascend MSC: Data: 0x5451,A,01/31/2012 02:15:56,0,-1.00,-1.0000,-1.0000,233,147,1,65,23.76,56.06,11.576,5.230e-01,10494.00,2224.00,1208.55,13.17,-205F0865CA6C3771A8758277AA783776F1747870DE6CFA68B564FD61865F0F5D905CD95CC95DB35FB66219656E69646DF372FF789E7EB4847A89E78EF3931495CD97649719954C91EE8D7287EE816D7B1A74A66EAE692263E85F825BAE5857557D52FD510E4F924EA04DD74D6D4D61,6620.2 $ 12-Dec-2018 19:50:55.133 Ascend Vel PID Values 0.050000 0.020000 0.020033 -0.009967 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:55.133 Ascend SBE41 Message 2.39, 22.3517, 34.1972 2.390000 2.509818 0.156590 0.020000 0.025000 0.043338 1.000000 $ 12-Dec-2018 19:50:55.806 Ascend Vel PID Values 0.050000 0.040000 0.039934 0.019900 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:55.806 Ascend SBE41 Message 2.35, 22.3524, 34.1967 2.350000 2.484649 0.158748 0.040000 0.030000 0.045313 1.000000 $ 12-Dec-2018 19:50:56.898 Ascend Vel PID Values 0.050000 -0.040000 -0.039734 -0.079668 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:56.898 Ascend SBE41 Message 2.39, 22.3530, 34.1964 2.390000 2.463973 0.156833 -0.040000 0.000000 0.047928 1.000000 $ 12-Dec-2018 19:50:57.350 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.390000 155.077711 29.100000 163.000000 $ 12-Dec-2018 19:50:57.461 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4693335 $ 12-Dec-2018 19:50:57.467 Ascend MSC: Done Sampling. $ 12-Dec-2018 19:50:57.570 Ascend Starting pH sample $ 12-Dec-2018 19:50:57.769 Ascend MSC: OUT: W $ 12-Dec-2018 19:50:58.123 Ascend MSC: OUT: W $ 12-Dec-2018 19:50:57.871 Ascend Vel PID Values 0.050000 -0.310000 -0.309101 -0.269367 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:57.871 Ascend SBE41 Message 2.70, 22.3531, 34.1965 2.700000 2.439471 0.145019 -0.310000 -0.175000 0.050764 1.000000 $ 12-Dec-2018 19:50:58.568 Ascend MSC: RX: ACK $ 12-Dec-2018 19:50:58.578 Ascend MSC: Got ACK $ 12-Dec-2018 19:50:58.981 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.700000 155.088320 29.100000 163.000000 $ 12-Dec-2018 19:50:59.092 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6253107 $ 12-Dec-2018 19:50:59.195 Ascend MSC: OUT: MODE,2 $ 12-Dec-2018 19:50:59.300 Ascend MSC: RX: ACK $ 12-Dec-2018 19:50:59.304 Ascend MSC: Got ACK $ 12-Dec-2018 19:50:58.803 Ascend Vel PID Values 0.050000 -0.020000 -0.020964 0.288137 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:58.803 Ascend SBE41 Message 2.72, 22.3531, 34.1967 2.720000 2.415065 0.117707 -0.020000 -0.165000 0.053541 1.000000 $ 12-Dec-2018 19:50:59.848 Ascend MSC: RX: ACK,MODE,2 $ 12-Dec-2018 19:50:59.847 Ascend Vel PID Values 0.050000 0.020000 0.019865 0.040829 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:50:59.847 Ascend SBE41 Message 2.70, 22.3531, 34.1969 2.700000 2.403177 0.078779 0.020000 0.000000 0.056118 1.000000 $ 12-Dec-2018 19:51:00.495 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.700000 155.064456 29.100000 163.000000 $ 12-Dec-2018 19:51:00.606 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5086708 $ 12-Dec-2018 19:51:00.913 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.700000 155.086465 29.100000 163.000000 $ 12-Dec-2018 19:51:01.613 Ascend MSC: OUT: ACK $ 12-Dec-2018 19:51:00.800 Ascend Vel PID Values 0.050000 0.010000 0.010033 -0.009832 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:00.800 Ascend SBE41 Message 2.69, 22.3535, 34.1968 2.690000 2.425960 0.040047 0.010000 0.015000 0.058353 1.000000 $ 12-Dec-2018 19:51:01.800 Ascend Vel PID Values 0.050000 0.010000 0.010000 -0.000033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:01.800 Ascend SBE41 Message 2.68, 22.3538, 34.1968 2.680000 2.495526 0.010207 0.010000 0.010000 0.059941 1.000000 $ 12-Dec-2018 19:51:02.604 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.680000 155.091174 29.100000 163.000000 $ 12-Dec-2018 19:51:02.717 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1041055 $ 12-Dec-2018 19:51:02.820 Ascend Vel PID Values 0.050000 -0.010000 -0.009933 -0.019933 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:02.820 Ascend SBE41 Message 2.69, 22.3539, 34.1971 2.690000 2.588299 -0.009698 -0.010000 0.000000 0.060528 1.000000 $ 12-Dec-2018 19:51:03.367 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.690000 155.097619 29.100000 163.000000 $ 12-Dec-2018 19:51:03.723 Ascend MSC: OUT: TS $ 12-Dec-2018 19:51:03.825 Ascend Vel PID Values 0.050000 0.000000 -0.000033 0.009900 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:03.825 Ascend SBE41 Message 2.69, 22.3545, 34.1966 2.690000 2.659997 -0.021685 0.000000 -0.005000 0.059943 1.000000 $ 12-Dec-2018 19:51:04.373 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.690000 155.101389 29.100000 163.000000 $ 12-Dec-2018 19:51:04.723 Ascend MSC: RX: ACK,TS,CMD $ 12-Dec-2018 19:51:05.028 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.690000 155.068405 29.100000 163.000000 $ 12-Dec-2018 19:51:04.825 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000033 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:04.825 Ascend SBE41 Message 2.69, 22.3546, 34.1968 2.690000 2.689994 -0.027964 0.000000 0.000000 0.058311 1.000000 $ 12-Dec-2018 19:51:05.795 Ascend Vel PID Values 0.050000 0.000000 -0.000000 0.000000 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:05.795 Ascend SBE41 Message 2.69, 22.3549, 34.1969 2.690000 2.692601 -0.031325 0.000000 0.000000 0.055945 1.000000 $ 12-Dec-2018 19:51:06.612 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.690000 155.078702 29.100000 163.000000 $ 12-Dec-2018 19:51:06.723 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0010182 $ 12-Dec-2018 19:51:06.826 Ascend Vel PID Values 0.050000 0.160000 0.159468 0.159468 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:06.826 Ascend SBE41 Message 2.53, 22.3557, 34.1965 2.530000 2.689136 -0.033915 0.160000 0.080000 0.053089 1.000000 $ 12-Dec-2018 19:51:07.374 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.530000 155.099683 29.100000 163.000000 $ 12-Dec-2018 19:51:07.931 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.530000 155.093201 29.100000 163.000000 $ 12-Dec-2018 19:51:07.793 Ascend Vel PID Values 0.050000 0.660000 0.658335 0.498868 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:07.793 Ascend SBE41 Message 1.87, 22.3558, 34.1969 1.870000 2.687668 -0.035195 0.660000 0.410000 0.049871 1.000000 $ 12-Dec-2018 19:51:08.792 Ascend Vel PID Values 0.050000 0.390000 0.390896 -0.267439 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:08.792 Ascend SBE41 Message 1.48, 22.3558, 34.1974 1.480000 2.682014 -0.031669 0.390000 0.525000 0.046336 1.000000 $ 12-Dec-2018 19:51:09.619 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 1.480000 155.094065 29.100000 163.000000 $ 12-Dec-2018 19:51:09.730 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0012486 $ 12-Dec-2018 19:51:09.841 Ascend ERROR: Missed PH message 9 $ 12-Dec-2018 19:51:09.947 Ascend Sending Optode Do Sample $ 12-Dec-2018 19:51:09.951 Ascend Sending Optode Wakeup $ 12-Dec-2018 19:51:10.650 Ascend Sending FLBB run command $ 12-Dec-2018 19:51:10.667 Ascend Sending radiometer pollSample $ 12-Dec-2018 19:51:10.871 Ascend Sending SBE41 stopProfile $ 12-Dec-2018 19:51:09.834 Ascend Vel PID Values 0.050000 0.040000 0.041166 -0.349730 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:09.834 Ascend SBE41 Message 1.44, 22.3569, 34.1965 1.440000 2.645907 -0.018595 0.040000 0.215000 0.042689 1.000000 $ 12-Dec-2018 19:51:10.870 Ascend Vel PID Values 0.050000 0.000000 0.000135 -0.041031 NaN NaN NaN 0.000000 1.000000 $ 12-Dec-2018 19:51:10.870 Ascend SBE41 Message 1.44, 22.3570, 34.1969 1.440000 2.528960 0.007336 0.000000 0.020000 0.039556 1.000000 $ 12-Dec-2018 19:51:11.576 Ascend Radiometer Message SATFI40287,-0.0051,0.0023,-0.0066,-0.2057 $ 12-Dec-2018 19:51:11.042 Ascend Unparsed SBE41 Message profile stopped $ 12-Dec-2018 19:51:12.114 Ascend Sending SBE41 stopProfile $ 12-Dec-2018 19:51:12.118 Ascend Powering up GPS $ 12-Dec-2018 19:51:12.234 Ascend Powering up BT Module $ 12-Dec-2018 19:51:12.433 Ascend Normal State Exit $ 12-Dec-2018 19:51:12.437 Ascend RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 1.440000 155.090891 29.100000 163.000000 $ 12-Dec-2018 19:51:12.651 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9157087 $ 12-Dec-2018 19:51:12.754 Init Profile State Entry $ 12-Dec-2018 19:51:12.758 Init Profile Initializing SBE 41 LPF $ 12-Dec-2018 19:51:12.968 Init Profile Sending SBE41 stopProfile $ 12-Dec-2018 19:51:14.084 Init Profile Resetting SBE41 with qsr $ 12-Dec-2018 19:51:14.088 Init Profile Sending qsr command $ 12-Dec-2018 19:51:11.789 Init Profile Optode Message 4330,1532,262.877,22.816,29.103,29.033,36.145,7.112,535.8,464.1,100.1 $ 12-Dec-2018 19:51:11.789 Init Profile Optode Message # $ 12-Dec-2018 19:51:16.402 Init Profile FLBB Message /99/99,99:99:99,695,2316,700,4130,532 $ 12-Dec-2018 19:51:12.230 Init Profile Unparsed SBE41 Message S>stopprofile $ 12-Dec-2018 19:51:16.933 Init Profile PTH Message 801.623291 24.100000 54.840607 25.018879 $ 12-Dec-2018 19:51:17.135 Init Profile Normal State Exit $ 12-Dec-2018 19:51:17.139 Init Profile RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 155.089810 29.125000 186.500000 $ 12-Dec-2018 19:51:17.352 Init Profile ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.5981582 $ 12-Dec-2018 19:51:17.359 Surface Ops Set Bellows State Entry $ 12-Dec-2018 19:51:17.564 Surface Ops Set Bellows Inflating bellows to Surface Ops position = 155.0 at 200000 cps $ 12-Dec-2018 19:51:13.083 Surface Ops Set Bellows Unparsed SBE41 Message ?cmd S>stopprofile $ 12-Dec-2018 19:51:14.293 Surface Ops Set Bellows Unparsed SBE41 Message ?cmd S>qsr $ 12-Dec-2018 19:51:14.293 Surface Ops Set Bellows Unparsed SBE41 Message powering down $ 12-Dec-2018 19:51:18.526 Surface Ops Set Bellows MSC: RX: ACK,TS,DAT $ 12-Dec-2018 19:51:16.609 Surface Ops Set Bellows Unparsed SBE41 Message S>SBE 41CP UW V 2.0 $ 12-Dec-2018 19:51:18.948 Surface Ops Set Bellows RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 155.079477 29.125000 186.500000 $ 12-Dec-2018 19:51:19.061 Surface Ops Set Bellows ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7012919 $ 12-Dec-2018 19:51:19.472 Surface Ops Set Bellows RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 155.062705 29.125000 186.500000 $ 12-Dec-2018 19:51:20.471 Surface Ops Set Bellows RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.951334 29.125000 186.500000 $ 12-Dec-2018 19:51:21.471 Surface Ops Set Bellows Normal State Exit $ 12-Dec-2018 19:51:21.476 Surface Ops Set Bellows RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.797949 29.125000 186.500000 $ 12-Dec-2018 19:51:22.067 Dump CP Data State Entry $ 12-Dec-2018 19:51:22.072 Dump CP Data Starting valve close $ 12-Dec-2018 19:51:22.278 Dump CP Data Didn't get CR/LF response, trying again $ 12-Dec-2018 19:51:22.585 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.706128 29.125000 186.500000 $ 12-Dec-2018 19:51:23.068 Dump CP Data Didn't get CR/LF response, trying again $ 12-Dec-2018 19:51:22.278 Dump CP Data CP Message S> $ 12-Dec-2018 19:52:10.758 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.668234 29.125000 186.500000 $ 12-Dec-2018 19:52:10.871 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:47.8034677 $ 12-Dec-2018 19:52:10.974 Dump CP Data Got CR/LF response $ 12-Dec-2018 19:52:11.180 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.654846 29.125000 186.500000 $ 12-Dec-2018 19:52:11.877 Dump CP Data Sending binaverage wait command $ 12-Dec-2018 19:52:11.883 Dump CP Data Sending binaverage $ 12-Dec-2018 19:52:12.095 Dump CP Data Trying again for binaverage response $ 12-Dec-2018 19:52:12.094 Dump CP Data CP Message S>binaverage $ 12-Dec-2018 19:52:12.095 Dump CP Data CP Message samples = 418, maxPress = 25.68 $ 12-Dec-2018 19:52:20.691 Dump CP Data CP Message rd: 0 $ 12-Dec-2018 19:52:20.691 Dump CP Data CP Message rd: 128 $ 12-Dec-2018 19:52:20.691 Dump CP Data CP Message rd: 256 $ 12-Dec-2018 19:52:20.692 Dump CP Data CP Message rd: 384 $ 12-Dec-2018 19:52:20.692 Dump CP Data CP Message avg: 0 $ 12-Dec-2018 19:52:20.692 Dump CP Data CP Message $ 12-Dec-2018 19:52:20.693 Dump CP Data CP Message done, nbins = 14 $ 12-Dec-2018 19:52:28.877 Dump CP Data PTH Message 801.364746 24.008333 54.932159 25.018879 $ 12-Dec-2018 19:52:29.079 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.683292 29.150000 166.000000 $ 12-Dec-2018 19:52:29.191 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:17.3137978 $ 12-Dec-2018 19:52:29.197 Dump CP Data Sending binaverage wait command $ 12-Dec-2018 19:52:29.299 Dump CP Data Got good binaverage response $ 12-Dec-2018 19:52:29.700 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.672012 29.150000 166.000000 $ 12-Dec-2018 19:52:30.198 Dump CP Data Sending da wait command $ 12-Dec-2018 19:52:30.300 Dump CP Data Sending da command $ 12-Dec-2018 19:52:30.304 Dump CP Data Trying again for da response $ 12-Dec-2018 19:52:30.405 Dump CP Data CP Message S>da $ 12-Dec-2018 19:52:30.406 Dump CP Data CP Message 0.00, 0.0000, 0.0000, 0 $ 12-Dec-2018 19:52:30.510 Dump CP Data CP Message 2.41, 22.3532, 34.1968, 25 $ 12-Dec-2018 19:52:34.145 Dump CP Data CP Message 4.07, 22.3442, 34.1961, 38 $ 12-Dec-2018 19:52:34.146 Dump CP Data CP Message 5.95, 22.3325, 34.1952, 38 $ 12-Dec-2018 19:52:34.147 Dump CP Data CP Message 8.03, 22.3204, 34.1943, 44 $ 12-Dec-2018 19:52:34.148 Dump CP Data CP Message 10.06, 22.3072, 34.1934, 34 $ 12-Dec-2018 19:52:34.149 Dump CP Data CP Message 11.87, 22.2966, 34.1924, 36 $ 12-Dec-2018 19:52:34.150 Dump CP Data CP Message 13.55, 22.2850, 34.1917, 25 $ 12-Dec-2018 19:52:34.151 Dump CP Data CP Message 15.77, 22.2711, 34.1909, 40 $ 12-Dec-2018 19:52:34.152 Dump CP Data CP Message 18.15, 22.2566, 34.1899, 33 $ 12-Dec-2018 19:52:34.152 Dump CP Data CP Message 19.96, 22.2455, 34.1889, 30 $ 12-Dec-2018 19:52:34.153 Dump CP Data CP Message 22.26, 22.2296, 34.1878, 42 $ 12-Dec-2018 19:52:34.154 Dump CP Data CP Message 24.25, 22.2113, 34.1864, 26 $ 12-Dec-2018 19:52:34.155 Dump CP Data CP Message 25.58, 22.2039, 34.1854, 7 $ 12-Dec-2018 19:52:34.155 Dump CP Data CP Message upload complete $ 12-Dec-2018 19:52:40.840 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.673539 29.150000 166.000000 $ 12-Dec-2018 19:52:40.953 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.7549022 $ 12-Dec-2018 19:52:40.958 Dump CP Data Sending da wait command $ 12-Dec-2018 19:52:41.060 Dump CP Data Good da response; Upload sucessful $ 12-Dec-2018 19:52:41.364 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.673211 29.150000 166.000000 $ 12-Dec-2018 19:52:48.370 Dump CP Data Sending dah wait command $ 12-Dec-2018 19:52:48.375 Dump CP Data Sending dah command $ 12-Dec-2018 19:52:48.581 Dump CP Data Trying again for dah response $ 12-Dec-2018 19:52:48.578 Dump CP Data CP Message S>dah $ 12-Dec-2018 19:53:55.175 Dump CP Data Appending CP Data: 00000000000000 $ 12-Dec-2018 19:52:48.579 Dump CP Data CP Message 00000000000000 $ 12-Dec-2018 19:54:51.211 Dump CP Data Appending CP Data: 00185751859519 $ 12-Dec-2018 19:52:48.579 Dump CP Data CP Message 00185751859519 $ 12-Dec-2018 19:54:53.128 Dump CP Data Appending CP Data: 00295748859426 $ 12-Dec-2018 19:52:48.580 Dump CP Data CP Message 00295748859426 $ 12-Dec-2018 19:54:54.934 Dump CP Data Appending CP Data: 003B573C859326 $ 12-Dec-2018 19:52:48.580 Dump CP Data CP Message 003B573C859326 $ 12-Dec-2018 19:54:56.620 Dump CP Data Appending CP Data: 0050573085922C $ 12-Dec-2018 19:52:58.099 Dump CP Data CP Message 0050573085922C $ 12-Dec-2018 19:55:06.500 Dump CP Data Appending CP Data: 00655723859122 $ 12-Dec-2018 19:52:58.100 Dump CP Data CP Message 00655723859122 $ 12-Dec-2018 19:55:07.777 Dump CP Data Appending CP Data: 00775719859024 $ 12-Dec-2018 19:52:58.100 Dump CP Data CP Message 00775719859024 $ 12-Dec-2018 19:55:09.950 Dump CP Data Appending CP Data: 0087570D859019 $ 12-Dec-2018 19:52:58.101 Dump CP Data CP Message 0087570D859019 $ 12-Dec-2018 19:55:11.509 Dump CP Data Appending CP Data: 009E56FF858F28 $ 12-Dec-2018 19:52:58.101 Dump CP Data CP Message 009E56FF858F28 $ 12-Dec-2018 19:55:13.707 Dump CP Data Appending CP Data: 00B656F1858E21 $ 12-Dec-2018 19:52:58.102 Dump CP Data CP Message 00B656F1858E21 $ 12-Dec-2018 19:55:15.481 Dump CP Data Appending CP Data: 00C856E5858D1E $ 12-Dec-2018 19:52:58.102 Dump CP Data CP Message 00C856E5858D1E $ 12-Dec-2018 19:55:16.999 Dump CP Data Appending CP Data: 00DF56D6858C2A $ 12-Dec-2018 19:52:58.103 Dump CP Data CP Message 00DF56D6858C2A $ 12-Dec-2018 19:55:18.718 Dump CP Data Appending CP Data: 00F356C3858A1A $ 12-Dec-2018 19:52:58.103 Dump CP Data CP Message 00F356C3858A1A $ 12-Dec-2018 19:55:20.518 Dump CP Data Appending CP Data: 010056BC858907 $ 12-Dec-2018 19:52:58.104 Dump CP Data CP Message 010056BC858907 $ 12-Dec-2018 19:52:58.104 Dump CP Data CP Message upload complete $ 12-Dec-2018 19:55:20.942 Dump CP Data PTH Message 800.188232 24.233333 55.092377 25.061780 $ 12-Dec-2018 19:55:21.144 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.680334 29.150000 190.500000 $ 12-Dec-2018 19:55:21.255 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:02:39.2966356 $ 12-Dec-2018 19:55:21.260 Dump CP Data Sending dah wait command $ 12-Dec-2018 19:55:21.364 Dump CP Data Good dah response; Upload sucessful $ 12-Dec-2018 19:55:21.667 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.711016 29.150000 190.500000 $ 12-Dec-2018 19:55:23.262 Dump CP Data Calculated new PID Constant, h = 3000 $ 12-Dec-2018 19:55:22.589 Dump CP Data CP Message S>SBE 41CP UW V 2.0 $ 12-Dec-2018 19:55:23.674 Dump CP Data Normal State Exit $ 12-Dec-2018 19:55:23.680 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.698618 29.150000 190.500000 $ 12-Dec-2018 19:55:23.897 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6362101 $ 12-Dec-2018 19:55:23.902 Surface Ops State Entry $ 12-Dec-2018 19:55:24.105 Surface Ops Powering up Iridium Modem $ 12-Dec-2018 19:55:35.001 Surface Ops Starting valve close $ 12-Dec-2018 19:55:35.006 Surface Ops Sending Optode Do Sample $ 12-Dec-2018 19:55:35.205 Surface Ops Sending Optode Wakeup $ 12-Dec-2018 19:55:35.927 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.440000 154.711753 29.150000 190.500000 $ 12-Dec-2018 19:55:36.039 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.5078965 $ 12-Dec-2018 19:55:36.142 Surface Ops Sending CREG cmd $ 12-Dec-2018 19:55:24.252 Surface Ops SBE41 Message 0.94 0.940000 1.439996 -0.000000 0.166667 0.083333 0.000000 3.000000 $ 12-Dec-2018 19:55:27.119 Surface Ops A3LA Message $ 12-Dec-2018 19:55:36.485 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:27.121 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:36.697 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:27.239 Surface Ops SBE41 Message -0.12 -0.120000 1.438928 -0.000013 0.353333 0.260000 0.000002 3.000000 $ 12-Dec-2018 19:55:28.121 Surface Ops A3LA Message $ 12-Dec-2018 19:55:37.036 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:28.123 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:37.250 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:29.122 Surface Ops A3LA Message $ 12-Dec-2018 19:55:37.465 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:29.124 Surface Ops A3LA Message 0 $ 12-Dec-2018 19:55:37.677 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->0 <-- $ 12-Dec-2018 19:55:37.983 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.120000 154.689111 29.150000 190.500000 $ 12-Dec-2018 19:55:38.095 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0504903 $ 12-Dec-2018 19:55:29.125 Surface Ops A3LA Message $ 12-Dec-2018 19:55:38.306 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:29.127 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:38.522 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:30.121 Surface Ops A3LA Message $ 12-Dec-2018 19:55:38.734 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:30.130 Surface Ops A3LA Message 300125060561320 $ 12-Dec-2018 19:55:38.948 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->300125060561320 <-- $ 12-Dec-2018 19:55:30.132 Surface Ops A3LA Message $ 12-Dec-2018 19:55:39.160 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:30.133 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:39.373 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:30.240 Surface Ops SBE41 Message -0.11 -0.110000 1.424676 -0.000138 -0.003333 0.175000 0.000020 3.000000 $ 12-Dec-2018 19:55:31.122 Surface Ops A3LA Message $ 12-Dec-2018 19:55:39.709 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:31.123 Surface Ops A3LA Message 0 $ 12-Dec-2018 19:55:39.922 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->0 <-- $ 12-Dec-2018 19:55:31.124 Surface Ops A3LA Message $ 12-Dec-2018 19:55:40.133 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:31.127 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:40.347 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:32.122 Surface Ops A3LA Message $ 12-Dec-2018 19:55:40.562 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:32.124 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:40.774 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:40.983 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 154.703967 29.150000 190.500000 $ 12-Dec-2018 19:55:41.095 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9947408 $ 12-Dec-2018 19:55:33.123 Surface Ops A3LA Message $ 12-Dec-2018 19:55:41.308 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:33.134 Surface Ops A3LA Message 8988169234000597401 $ 12-Dec-2018 19:55:41.522 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->8988169234000597401 <-- $ 12-Dec-2018 19:55:33.135 Surface Ops A3LA Message $ 12-Dec-2018 19:55:41.735 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:33.138 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:41.949 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:33.240 Surface Ops SBE41 Message -0.10 -0.100000 1.348182 -0.000430 -0.003333 -0.003333 0.000099 3.000000 $ 12-Dec-2018 19:55:36.251 Surface Ops A3LA Message $ 12-Dec-2018 19:55:42.286 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:36.251 Surface Ops A3LA Message +CREG:000,004 $ 12-Dec-2018 19:55:42.498 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->+CREG:000,004 <-- $ 12-Dec-2018 19:55:36.251 Surface Ops A3LA Message $ 12-Dec-2018 19:55:42.709 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 12-Dec-2018 19:55:36.252 Surface Ops A3LA Message OK $ 12-Dec-2018 19:55:42.922 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 12-Dec-2018 19:55:36.803 Surface Ops Optode Message %!4330,1532,262.783,22.824,29.104,29.034,36.139,7.105,535.8,465.1,99.9 $ 12-Dec-2018 19:55:36.804 Surface Ops Optode Message # $ 12-Dec-2018 19:55:37.933 Surface Ops SBE41 Message 0.01 0.010000 1.127211 0.000588 -0.036667 -0.020000 0.000309 3.000000 $ 12-Dec-2018 19:55:43.479 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.010000 154.701620 29.150000 190.500000 $ 12-Dec-2018 19:55:43.591 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4904819 $ 12-Dec-2018 19:55:40.923 Surface Ops SBE41 Message 0.62 0.620000 0.743412 0.008123 -0.203333 -0.120000 0.000685 3.000000 $ 12-Dec-2018 19:55:44.022 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.620000 154.699072 29.150000 190.500000 $ 12-Dec-2018 19:55:43.868 Surface Ops SBE41 Message 0.65 0.650000 0.328616 0.028700 -0.010000 -0.106667 0.001172 3.000000 $ 12-Dec-2018 19:55:44.927 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.650000 154.724553 29.150000 190.500000 $ 12-Dec-2018 19:55:45.800 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.650000 154.713556 29.150000 190.500000 $ 12-Dec-2018 19:55:46.801 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.650000 154.707812 29.150000 190.500000 $ 12-Dec-2018 19:55:46.912 Surface Ops SBE41 Message -0.11 -0.110000 0.069138 0.061602 0.253333 0.121667 0.001656 3.000000 $ 12-Dec-2018 19:55:47.828 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 154.710151 29.150000 190.500000 $ 12-Dec-2018 19:55:48.802 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 154.708803 29.150000 190.500000 $ 12-Dec-2018 19:55:49.802 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 154.719636 29.150000 190.500000 $ 12-Dec-2018 19:55:49.913 Surface Ops SBE41 Message -0.10 -0.100000 0.040320 0.094105 -0.003333 0.125000 0.002041 3.000000 $ 12-Dec-2018 19:55:50.832 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.100000 154.718317 29.150000 190.500000 $ 12-Dec-2018 19:55:51.803 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.100000 154.742867 29.150000 190.500000 $ 12-Dec-2018 19:55:52.803 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.100000 154.713109 29.150000 190.500000 $ 12-Dec-2018 19:55:52.920 Surface Ops SBE41 Message -0.11 -0.110000 0.171833 0.107845 0.003333 0.000000 0.002297 3.000000 $ 12-Dec-2018 19:55:53.829 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 154.714659 29.150000 190.500000 $ 12-Dec-2018 19:55:54.803 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 154.709391 29.150000 190.500000 $ 12-Dec-2018 19:56:03.802 Surface Ops ERROR: Missed PH message 10 $ 12-Dec-2018 19:56:03.807 Surface Ops ERROR: Missed NO3 message 9 $ 12-Dec-2018 19:56:20.373 Surface Ops Writing CP data to Sci File $ 12-Dec-2018 19:56:20.479 Surface Ops Writing Footer to Sci File