$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	13-Dec-2018	23:41:06.789	SM Not Running	Reset Controller Status Register Value = 65792

$	13-Dec-2018	23:41:06.794	SM Not Running	File Name = \SD\data\2018-12-13T23-41-5.eng

$	13-Dec-2018	23:41:06.798	SM Not Running	Volume Total Size:     7939817472

$	13-Dec-2018	23:41:06.803	SM Not Running	Volume Free Space:     7873658880

$	13-Dec-2018	23:41:06.807	SM Not Running	PlatVel PID K = 80

$	13-Dec-2018	23:41:06.811	SM Not Running	PlatVel PID Ti = 50000

$	13-Dec-2018	23:41:06.816	SM Not Running	PlatVel PID Td = 10

$	13-Dec-2018	23:41:06.820	SM Not Running	PlatVel PID Tf = 10

$	13-Dec-2018	23:41:06.824	SM Not Running	PlatVel PID Tt = 100

$	13-Dec-2018	23:41:06.828	SM Not Running	PlatVel PID B = 1

$	13-Dec-2018	23:41:06.832	SM Not Running	PlatVel PID uLow = -50

$	13-Dec-2018	23:41:06.836	SM Not Running	PlatVel PID uHigh = 50

$	13-Dec-2018	23:41:06.840	SM Not Running	PlatVel PID h = 3

$	13-Dec-2018	23:41:06.844	SM Not Running	Engr Logger Initialized

$	13-Dec-2018	23:41:13.783	SM Not Running	Initializing Bluetooth Console

$	13-Dec-2018	23:41:14.788	SM Not Running	Initializing GPS and synching time

$	13-Dec-2018	23:41:16.001	SM Not Running	Creating Mission

$	13-Dec-2018	23:41:16.104	SM Not Running	Maximum number of profiles = 10

$	13-Dec-2018	23:41:16.208	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 12/13/2018 23:41:16

$	13-Dec-2018	23:41:16.314	SM Not Running	Recovery mode = True

$	13-Dec-2018	23:41:16.419	SM Not Running	Park Sample Period = 00:01:00

$	13-Dec-2018	23:41:16.533	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	13-Dec-2018	23:41:16.659	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:16.766	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:16.873	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:16.980	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.088	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.196	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.302	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.409	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.516	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.623	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.730	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.839	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:17.946	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.053	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.160	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.267	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.374	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.481	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.595	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.702	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.810	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:18.917	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:19.025	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:19.132	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:19.243	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:19.350	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:19.459	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.050, 00:00:00, 7

$	13-Dec-2018	23:41:19.561	SM Not Running	Initializing Buoyancy Engine

$	13-Dec-2018	23:41:19.664	SM Not Running	Starting valve close

$	13-Dec-2018	23:41:19.767	Init Mission	State Entry

$	13-Dec-2018	23:41:19.772	Init Mission	Initializing FLBB

$	13-Dec-2018	23:41:24.377	Init Mission	Sending FLBB stop command

$	13-Dec-2018	23:41:25.882	Init Mission	Sending FLBB pkt command: $pkt 1  

$	13-Dec-2018	23:41:26.987	Init Mission	Sending FLBB ave command: $ave 10  

$	13-Dec-2018	23:41:28.994	Init Mission	Initializing Iridium Modem

$	13-Dec-2018	23:41:38.598	Init Mission	Initializing SBE41

$	13-Dec-2018	23:41:44.208	Init Mission	Sending SBE41 stopProfile

$	13-Dec-2018	23:41:45.213	Init Mission	pcutoff=1 

$	13-Dec-2018	23:41:46.218	Init Mission	Sending outputPTSyes

$	13-Dec-2018	23:41:47.223	Init Mission	Sending tsWait

$	13-Dec-2018	23:41:48.227	Init Mission	Sending 11 bin setup commands

$	13-Dec-2018	23:41:54.834	Init Mission	Initializing Optode

$	13-Dec-2018	23:41:55.436	Init Mission	Sending Optode Wakeup

$	13-Dec-2018	23:42:00.443	Init Mission	Initializing Pressure, Temperature, Humidity sensor

$	13-Dec-2018	23:42:00.950	Init Mission	Set can pressure resolution to low

$	13-Dec-2018	23:42:01.052	Init Mission	Set can pressure active

$	13-Dec-2018	23:42:01.056	Init Mission	PTH Message														786.259277	22.566667	54.703278	23.538816																			

$	13-Dec-2018	23:42:01.354	Init Mission	Initializing MSC

$	13-Dec-2018	23:42:01.859	Init Mission	MSC: OUT: INIT

$	13-Dec-2018	23:42:01.962	Init Mission	Initializing Radiometer 1

$	13-Dec-2018	23:42:02.474	Init Mission	Powering down OCR504

$	13-Dec-2018	23:42:07.478	Init Mission	Powering up OCR504

$	13-Dec-2018	23:41:32.601	Init Mission	A3LA Message																																			AT&D0   	

$	13-Dec-2018	23:41:32.603	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:41:33.601	Init Mission	A3LA Message																																			AT&K0   	

$	13-Dec-2018	23:41:33.603	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:41:34.604	Init Mission	A3LA Message																																			AT+SBDD2   	

$	13-Dec-2018	23:41:34.606	Init Mission	A3LA Message																																			0  	

$	13-Dec-2018	23:41:34.607	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	23:41:34.609	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:41:35.609	Init Mission	A3LA Message																																			AT+GSN    	

$	13-Dec-2018	23:41:35.618	Init Mission	A3LA Message																																			300125060561320  	

$	13-Dec-2018	23:41:35.619	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	23:41:35.621	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:41:37.008	Init Mission	A3LA Message																																			AT+SBDC   	

$	13-Dec-2018	23:41:37.010	Init Mission	A3LA Message																																			0  	

$	13-Dec-2018	23:41:37.011	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	23:41:37.013	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:42:14.321	Init Mission	PTH Message														786.259277	22.633333	54.756683	23.538816																			

$	13-Dec-2018	23:42:14.524	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	31.025000	106.500000																																

$	13-Dec-2018	23:42:14.636	Init Mission	Starting valve close

$	13-Dec-2018	23:42:16.641	Init Mission	Closed valve isValveOpen = false

$	13-Dec-2018	23:42:16.738	Init Mission	Starting valve open

$	13-Dec-2018	23:42:18.840	Init Mission	Opened valve isValveOpen = true

$	13-Dec-2018	23:42:18.938	Init Mission	Starting valve close

$	13-Dec-2018	23:42:21.042	Init Mission	Closed valve isValveOpen = false

$	13-Dec-2018	23:41:37.609	Init Mission	A3LA Message																																			ATEn=0   	

$	13-Dec-2018	23:41:37.611	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:41:38.767	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	23:41:38.778	Init Mission	A3LA Message																																			8988169234000597401  	

$	13-Dec-2018	23:41:38.779	Init Mission	A3LA Message																																			  	

$	13-Dec-2018	23:41:38.781	Init Mission	A3LA Message																																			OK  	

$	13-Dec-2018	23:41:44.323	Init Mission	Unparsed SBE41 Message						S>stopprofile  																														

$	13-Dec-2018	23:41:45.326	Init Mission	Unparsed SBE41 Message						?cmd S>pcutoff=1  																														

$	13-Dec-2018	23:41:46.333	Init Mission	Unparsed SBE41 Message						S>outputpts=y  																														

$	13-Dec-2018	23:41:47.335	Init Mission	Unparsed SBE41 Message						S>tswait=2  																														

$	13-Dec-2018	23:41:48.364	Init Mission	Unparsed SBE41 Message						S>autobinavg=n  																														

$	13-Dec-2018	23:41:48.879	Init Mission	Unparsed SBE41 Message						S>top_bin_interval=2  																														

$	13-Dec-2018	23:41:49.369	Init Mission	Unparsed SBE41 Message						S>top_bin_size=2  																														

$	13-Dec-2018	23:41:49.869	Init Mission	Unparsed SBE41 Message						S>top_bin_max=10  																														

$	13-Dec-2018	23:41:50.386	Init Mission	Unparsed SBE41 Message						S>middle_bin_interval=2  																														

$	13-Dec-2018	23:42:23.140	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	31.025000	106.500000																																

$	13-Dec-2018	23:42:23.251	Init Mission	Starting valve open

$	13-Dec-2018	23:42:23.459	Init Mission	Bellows inside limits

$	13-Dec-2018	23:41:50.877	Init Mission	Unparsed SBE41 Message						S>middle_bin_size=2  																														

$	13-Dec-2018	23:41:51.377	Init Mission	Unparsed SBE41 Message						S>middle_bin_max=20  																														

$	13-Dec-2018	23:41:51.888	Init Mission	Unparsed SBE41 Message						S>bottom_bin_interval=2  																														

$	13-Dec-2018	23:41:52.377	Init Mission	Unparsed SBE41 Message						S>bottom_bin_size=2  																														

$	13-Dec-2018	23:41:52.891	Init Mission	Unparsed SBE41 Message						S>includetransitionbin=n  																														

$	13-Dec-2018	23:41:53.369	Init Mission	Unparsed SBE41 Message						S>includenbin=y  																														

$	13-Dec-2018	23:41:56.466	Init Mission	Optode Message																												!#  								

$	13-Dec-2018	23:41:57.472	Init Mission	Optode Message																												#  								

$	13-Dec-2018	23:41:58.489	Init Mission	Optode Message																												#  								

$	13-Dec-2018	23:42:24.601	Init Mission	MSC: RX: 

$	13-Dec-2018	23:42:24.703	Init Mission	MSC: RX: 

$	13-Dec-2018	23:42:24.708	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	13-Dec-2018	23:42:24.908	Init Mission	MSC: RX:   MBARI Serial Number : 0777 

$	13-Dec-2018	23:42:24.913	Init Mission	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	13-Dec-2018	23:42:25.015	Init Mission	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	13-Dec-2018	23:42:25.222	Init Mission	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	13-Dec-2018	23:42:25.436	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	142.422996	31.025000	106.500000																																

$	13-Dec-2018	23:42:26.851	Init Mission	Increasing bellows position		143.214718																																		

$	13-Dec-2018	23:42:29.063	Init Mission	Increasing bellows position		143.504895																																		

$	13-Dec-2018	23:42:31.274	Init Mission	Increasing bellows position		143.895276																																		

$	13-Dec-2018	23:42:33.484	Init Mission	Increasing bellows position		144.143127																																		

$	13-Dec-2018	23:42:35.695	Init Mission	Increasing bellows position		144.330837																																		

$	13-Dec-2018	23:42:37.906	Init Mission	Increasing bellows position		144.359320																																		

$	13-Dec-2018	23:42:40.117	Init Mission	Increasing bellows position		144.393489																																		

$	13-Dec-2018	23:42:42.327	Init Mission	Increasing bellows position		144.418590																																		

$	13-Dec-2018	23:42:44.538	Init Mission	Increasing bellows position		144.429803																																		

$	13-Dec-2018	23:42:46.748	Init Mission	Increasing bellows position		144.440971																																		

$	13-Dec-2018	23:42:49.262	Init Mission	Decreasing bellows position		144.444279																																		

$	13-Dec-2018	23:42:51.472	Init Mission	Decreasing bellows position		144.455560																																		

$	13-Dec-2018	23:42:53.683	Init Mission	Decreasing bellows position		144.465335																																		

$	13-Dec-2018	23:42:55.990	Init Mission	Decreasing bellows position		144.449271																																		

$	13-Dec-2018	23:42:58.202	Init Mission	Decreasing bellows position		144.360915																																		

$	13-Dec-2018	23:43:00.412	Init Mission	Decreasing bellows position		144.314855																																		

$	13-Dec-2018	23:43:02.623	Init Mission	Decreasing bellows position		144.253530																																		

$	13-Dec-2018	23:43:04.834	Init Mission	Decreasing bellows position		144.256242																																		

$	13-Dec-2018	23:43:07.057	Init Mission	Decreasing bellows position		144.140363																																		

$	13-Dec-2018	23:43:09.267	Init Mission	Decreasing bellows position		144.077398																																		

$	13-Dec-2018	23:43:11.279	Init Mission	Radiometer Message																																	Firmware version: 5.1.0 - SatNet Type B 			

$	13-Dec-2018	23:43:11.377	Init Mission	Radiometer Message																																	Instrument: SATFI4 			

$	13-Dec-2018	23:43:11.486	Init Mission	Radiometer Message																																	S/N: 0287 			

$	13-Dec-2018	23:43:11.595	Init Mission	Radiometer Message																																	Reset Source: Power 			

$	13-Dec-2018	23:43:11.704	Init Mission	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	13-Dec-2018	23:43:11.812	Init Mission	Radiometer Message																																	Initializing system. Please wait... 			

$	13-Dec-2018	23:43:12.018	Init Mission	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	13-Dec-2018	23:43:12.122	Init Mission	MSC: RX:   CF Card: Size=256614400 Avail=99.08% 

$	13-Dec-2018	23:43:12.128	Init Mission	MSC: RX:   CF2 Power Up  (GMT): Wed Feb  1 06:07:15 2012 

$	13-Dec-2018	23:43:12.328	Init Mission	MSC: RX:   CF2 RTC Time  (GMT): Wed Feb  1 06:07:19 2012 

$	13-Dec-2018	23:43:12.431	Init Mission	MSC: RX:   Adjusted Local Time: Tue Jan 31 22:07:19 2012 

$	13-Dec-2018	23:43:12.436	Init Mission	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	13-Dec-2018	23:43:12.540	Init Mission	MSC: RX:   RTC delta (CF2 - DS3234) : -1.00 secs. 

$	13-Dec-2018	23:43:12.740	Init Mission	MSC: RX:   System Batt Voltage = 11.764 

$	13-Dec-2018	23:43:12.843	Init Mission	MSC: RX:   System Load Current = 2.62e-02 

$	13-Dec-2018	23:43:12.848	Init Mission	MSC: RX:   Housing Temperature = +22.37C = +72.26F 

$	13-Dec-2018	23:43:13.249	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	144.022241	31.025000	106.500000																																

$	13-Dec-2018	23:43:13.365	Init Mission	MSC: RX:   Housing    Humidity =  55.6%  =  13.1C (DP) 

$	13-Dec-2018	23:43:13.370	Init Mission	MSC: RX:   Power Cycle   Count = 165 

$	13-Dec-2018	23:43:13.473	Init Mission	MSC: RX:   System Reset  Count = 169 

$	13-Dec-2018	23:43:13.575	Init Mission	MSC: RX:   System Error  Count = 66 

$	13-Dec-2018	23:43:13.775	Init Mission	MSC: RX:   Last System   Error = -110 

$	13-Dec-2018	23:43:13.782	Init Mission	MSC: RX:   Last Error     Time = Tue Jan 31 02:58:15 2012 

$	13-Dec-2018	23:43:13.982	Init Mission	MSC: RX:   ISUS Error    Count = 1 

$	13-Dec-2018	23:43:14.084	Init Mission	MSC: RX:   Last ISUS     Error = -202 

$	13-Dec-2018	23:43:14.186	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	13-Dec-2018	23:43:14.192	Init Mission	MSC: RX:   DURA Error    Count = 0 

$	13-Dec-2018	23:43:14.294	Init Mission	MSC: RX:   Last DURA     Error = 0 

$	13-Dec-2018	23:43:14.495	Init Mission	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	13-Dec-2018	23:43:14.598	Init Mission	MSC: RX:   Fiberlite  Odometer = 100:12:26 = 360746 secs 

$	13-Dec-2018	23:43:14.603	Init Mission	MSC: RX:   Fiberlite    Cycles = 260 

$	13-Dec-2018	23:43:14.705	Init Mission	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	13-Dec-2018	23:43:14.808	Init Mission	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	13-Dec-2018	23:43:15.114	Init Mission	PTH Message														787.160645	22.833333	54.489655	23.688967																			

$	13-Dec-2018	23:43:15.315	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	143.982857	30.925000	156.000000																																

$	13-Dec-2018	23:43:15.427	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	23:43:15.431	Init Mission	Sending ds command

$	13-Dec-2018	23:43:15.533	Init Mission	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	13-Dec-2018	23:43:15.743	Init Mission	MSC: RX:   There are 72 records in the error file! 

$	13-Dec-2018	23:43:15.749	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	13-Dec-2018	23:43:15.954	Init Mission	MSC: RX:   Auto Shutdown in 10 hours at: Wed Feb  1 16:07:20 2012 

$	13-Dec-2018	23:43:16.057	Init Mission	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	13-Dec-2018	23:43:16.161	Init Mission	Radiometer Message																																	Autonomous operation enabled. 			

$	13-Dec-2018	23:42:13.028	Init Mission	SBE41 Message						   -0.32  	-0.320000	-0.000003	-0.000000	0.106667	0.053333	0.000000	3.000000																							

$	13-Dec-2018	23:43:16.603	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.991888	30.925000	156.000000																																

$	13-Dec-2018	23:43:16.715	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	23:43:17.022	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.988319	30.925000	156.000000																																

$	13-Dec-2018	23:43:17.715	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	23:43:15.634	Init Mission	Unparsed SBE41 Message						S>ds  																														

$	13-Dec-2018	23:43:15.741	Init Mission	Unparsed SBE41 Message						firmware compilation date: 18 December 2007 09:20  																														

$	13-Dec-2018	23:43:15.742	Init Mission	Unparsed SBE41 Message						stop profile when pressure is less than = 1.0 decibars  																														

$	13-Dec-2018	23:43:15.847	Init Mission	Unparsed SBE41 Message						automatic bin averaging at end of profile disabled  																														

$	13-Dec-2018	23:43:15.848	Init Mission	Unparsed SBE41 Message						number of samples = 497  																														

$	13-Dec-2018	23:43:15.848	Init Mission	Unparsed SBE41 Message						number of bins = 14  																														

$	13-Dec-2018	23:43:15.952	Init Mission	Unparsed SBE41 Message						top bin interval = 2  																														

$	13-Dec-2018	23:43:15.952	Init Mission	Unparsed SBE41 Message						top bin size = 2  																														

$	13-Dec-2018	23:43:15.953	Init Mission	Unparsed SBE41 Message						top bin max = 10  																														

$	13-Dec-2018	23:43:16.057	Init Mission	Unparsed SBE41 Message						middle bin interval = 2  																														

$	13-Dec-2018	23:43:16.161	Init Mission	Unparsed SBE41 Message						middle bin size = 2  																														

$	13-Dec-2018	23:43:16.271	Init Mission	Unparsed SBE41 Message						middle bin max = 20  																														

$	13-Dec-2018	23:43:19.332	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.965736	30.925000	156.000000																																

$	13-Dec-2018	23:43:19.445	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	23:43:16.272	Init Mission	Unparsed SBE41 Message						bottom bin interval = 2  																														

$	13-Dec-2018	23:43:16.273	Init Mission	Unparsed SBE41 Message						bottom bin size = 2  																														

$	13-Dec-2018	23:43:16.274	Init Mission	Unparsed SBE41 Message						do not include two transition bins  																														

$	13-Dec-2018	23:43:16.274	Init Mission	Unparsed SBE41 Message						include samples per bin  																														

$	13-Dec-2018	23:43:16.275	Init Mission	Unparsed SBE41 Message						pumped take sample wait time = 2 sec  																														

$	13-Dec-2018	23:43:16.276	Init Mission	Unparsed SBE41 Message						real-time output is PTS  																														

$	13-Dec-2018	23:43:20.355	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	144.005656	30.925000	156.000000																																

$	13-Dec-2018	23:43:20.471	Init Mission	Sending SBE41 ds command

$	13-Dec-2018	23:43:20.774	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	144.006588	30.925000	156.000000																																

$	13-Dec-2018	23:43:21.470	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	23:43:21.572	Init Mission	Sending dc command

$	13-Dec-2018	23:43:21.778	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.988773	30.925000	156.000000																																

$	13-Dec-2018	23:43:22.470	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	23:43:21.678	Init Mission	Unparsed SBE41 Message						S>dc  																														

$	13-Dec-2018	23:43:21.679	Init Mission	Unparsed SBE41 Message						temperature:  15-mar-14  																														

$	13-Dec-2018	23:43:21.706	Init Mission	Unparsed SBE41 Message						    TA0 =  3.536242e-05  																														

$	13-Dec-2018	23:43:21.742	Init Mission	Unparsed SBE41 Message						    TA1 =  2.674251e-04  																														

$	13-Dec-2018	23:43:21.891	Init Mission	Unparsed SBE41 Message						    TA2 = -1.901062e-06  																														

$	13-Dec-2018	23:43:21.891	Init Mission	Unparsed SBE41 Message						    TA3 =  1.365250e-07  																														

$	13-Dec-2018	23:43:21.892	Init Mission	Unparsed SBE41 Message						conductivity:  15-mar-14  																														

$	13-Dec-2018	23:43:21.893	Init Mission	Unparsed SBE41 Message						    G = -9.858232e-01  																														

$	13-Dec-2018	23:43:21.917	Init Mission	Unparsed SBE41 Message						    H =  1.476071e-01  																														

$	13-Dec-2018	23:43:21.950	Init Mission	Unparsed SBE41 Message						    I = -3.292498e-04  																														

$	13-Dec-2018	23:43:21.985	Init Mission	Unparsed SBE41 Message						    J =  4.505543e-05  																														

$	13-Dec-2018	23:43:22.023	Init Mission	Unparsed SBE41 Message						    CPCOR = -9.570001e-08  																														

$	13-Dec-2018	23:43:22.061	Init Mission	Unparsed SBE41 Message						    CTCOR =  3.250000e-06  																														

$	13-Dec-2018	23:43:22.100	Init Mission	Unparsed SBE41 Message						    WBOTC = -3.218098e-07  																														

$	13-Dec-2018	23:43:22.182	Init Mission	Unparsed SBE41 Message						pressure S/N = 4004719, range = 2900 psia:  10-mar-14  																														

$	13-Dec-2018	23:43:24.542	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.997081	30.925000	156.000000																																

$	13-Dec-2018	23:43:24.654	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	23:43:22.219	Init Mission	Unparsed SBE41 Message						    PA0 =  1.629284e-01  																														

$	13-Dec-2018	23:43:22.254	Init Mission	Unparsed SBE41 Message						    PA1 =  1.404717e-01  																														

$	13-Dec-2018	23:43:22.290	Init Mission	Unparsed SBE41 Message						    PA2 = -3.503310e-08  																														

$	13-Dec-2018	23:43:22.330	Init Mission	Unparsed SBE41 Message						    PTCA0 =  2.758681e+01  																														

$	13-Dec-2018	23:43:22.367	Init Mission	Unparsed SBE41 Message						    PTCA1 =  2.201518e-02  																														

$	13-Dec-2018	23:43:22.405	Init Mission	Unparsed SBE41 Message						    PTCA2 =  1.374282e-03  																														

$	13-Dec-2018	23:43:22.444	Init Mission	Unparsed SBE41 Message						    PTCB0 =  2.510888e+01  																														

$	13-Dec-2018	23:43:22.572	Init Mission	Unparsed SBE41 Message						    PTCB1 =  1.175000e-03  																														

$	13-Dec-2018	23:43:22.573	Init Mission	Unparsed SBE41 Message						    PTCB2 =  0.000000e+00  																														

$	13-Dec-2018	23:43:22.574	Init Mission	Unparsed SBE41 Message						    PTHA0 = -7.442904e+01  																														

$	13-Dec-2018	23:43:22.693	Init Mission	Unparsed SBE41 Message						    PTHA1 =  4.994783e-02  																														

$	13-Dec-2018	23:43:22.694	Init Mission	Unparsed SBE41 Message						    PTHA2 = -3.966033e-07  																														

$	13-Dec-2018	23:43:22.695	Init Mission	Unparsed SBE41 Message						    POFFSET =  0.000000e+00  																														

$	13-Dec-2018	23:43:26.485	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.999830	30.925000	156.000000																																

$	13-Dec-2018	23:43:26.598	Init Mission	Sending SBE41 dc command

$	13-Dec-2018	23:43:26.804	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.992729	30.925000	156.000000																																

$	13-Dec-2018	23:43:27.800	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.320000	143.994369	30.925000	156.000000																																

$	13-Dec-2018	23:43:28.599	Init Mission	Sending Optode GetAll

$	13-Dec-2018	23:43:28.603	Init Mission	Sending Optode Wakeup

$	13-Dec-2018	23:43:28.571	Init Mission	SBE41 Message						   -0.12  	-0.120000	-0.000679	-0.000008	-0.066667	0.020000	0.000000	3.000000																							

$	13-Dec-2018	23:43:29.372	Init Mission	Optode Message																												%!Product Name,4330,1532,Optode Sensor  								

$	13-Dec-2018	23:43:29.405	Init Mission	Optode Message																												Product Number,4330,1532,4330  								

$	13-Dec-2018	23:43:29.436	Init Mission	Optode Message																												Serial Number,4330,1532,1532  								

$	13-Dec-2018	23:43:29.462	Init Mission	Optode Message																												SW ID,4330,1532,1940006  								

$	13-Dec-2018	23:43:29.491	Init Mission	Optode Message																												SW Version,4330,1532,4,8,1  								

$	13-Dec-2018	23:43:29.532	Init Mission	Optode Message																												Node Description,4330,1532,optode 1532  								

$	13-Dec-2018	23:43:29.551	Init Mission	Optode Message																												Owner,4330,1532,  								

$	13-Dec-2018	23:43:29.582	Init Mission	Optode Message																												Salinity[PSU],4330,1532,0.00  								

$	13-Dec-2018	23:43:29.658	Init Mission	Optode Message																												PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	23:43:29.684	Init Mission	Optode Message																												FoilID,4330,1532,1206E  								

$	13-Dec-2018	23:43:29.903	Init Mission	Optode Message																												FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04  								

$	13-Dec-2018	23:43:30.118	Init Mission	Optode Message																												FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	23:43:30.201	Init Mission	Optode Message																												FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0  								

$	13-Dec-2018	23:43:34.096	Init Mission	Normal State Exit

$	13-Dec-2018	23:43:34.204	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	143.996410	30.925000	156.000000																																

$	13-Dec-2018	23:43:34.320	Init Profile	State Entry

$	13-Dec-2018	23:43:34.426	Init Profile	Initializing SBE 41 LPF

$	13-Dec-2018	23:43:34.533	Init Profile	Sending SBE41 stopProfile

$	13-Dec-2018	23:43:35.538	Init Profile	Resetting SBE41 with qsr

$	13-Dec-2018	23:43:35.543	Init Profile	Sending qsr command

$	13-Dec-2018	23:43:30.284	Init Profile	Optode Message																												FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0  								

$	13-Dec-2018	23:43:30.402	Init Profile	Optode Message																												SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	13-Dec-2018	23:43:30.452	Init Profile	Optode Message																												ConcCoef,4330,1532,-1.549127E+00,1.068129E+00  								

$	13-Dec-2018	23:43:30.489	Init Profile	Optode Message																												NomAirPress[hPa],4330,1532,1013.25  								

$	13-Dec-2018	23:43:30.518	Init Profile	Optode Message																												NomAirMix,4330,1532,0.20946  								

$	13-Dec-2018	23:43:30.560	Init Profile	Optode Message																												CalDataSat[Deg],4330,1532,31.61,10.06  								

$	13-Dec-2018	23:43:30.600	Init Profile	Optode Message																												CalDataAPress[hPa],4330,1532,1002.000  								

$	13-Dec-2018	23:43:30.643	Init Profile	Optode Message																												CalDataZero[Deg],4330,1532,61.907,21.413  								

$	13-Dec-2018	23:43:30.682	Init Profile	Optode Message																												Mode,4330,1532,Smart Sensor Terminal  								

$	13-Dec-2018	23:43:30.712	Init Profile	Optode Message																												Enable Sleep,4330,1532,Yes  								

$	13-Dec-2018	23:43:30.747	Init Profile	Optode Message																												Enable Polled Mode,4330,1532,Yes  								

$	13-Dec-2018	23:43:30.775	Init Profile	Optode Message																												Enable Text,4330,1532,No  								

$	13-Dec-2018	23:43:30.812	Init Profile	Optode Message																												Enable Decimalformat,4330,1532,Yes  								

$	13-Dec-2018	23:43:30.860	Init Profile	Optode Message																												Analog TempLimit[Deg.C],4330,1532,-5.00,35.00  								

$	13-Dec-2018	23:43:30.909	Init Profile	Optode Message																												Analog ConcLimit[Deg.C],4330,1532,0.00,800.00  								

$	13-Dec-2018	23:43:30.957	Init Profile	Optode Message																												Analog SatLimit[Deg.C],4330,1532,0.00,200.00  								

$	13-Dec-2018	23:43:39.640	Init Profile	Normal State Exit

$	13-Dec-2018	23:43:39.645	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.003615	30.925000	156.000000																																

$	13-Dec-2018	23:43:39.858	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.5380179

$	13-Dec-2018	23:43:39.865	Surface Ops Set Bellows	State Entry

$	13-Dec-2018	23:43:40.069	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	13-Dec-2018	23:43:31.006	Surface Ops Set Bellows	Optode Message																												Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00  								

$	13-Dec-2018	23:43:31.050	Surface Ops Set Bellows	Optode Message																												Analog Output,4330,1532,O2Concentration  								

$	13-Dec-2018	23:43:31.103	Surface Ops Set Bellows	Optode Message																												Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	13-Dec-2018	23:43:31.153	Surface Ops Set Bellows	Optode Message																												Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	13-Dec-2018	23:43:31.190	Surface Ops Set Bellows	Optode Message																												Enable AirSaturation,4330,1532,No  								

$	13-Dec-2018	23:43:31.221	Surface Ops Set Bellows	Optode Message																												Enable Rawdata,4330,1532,Yes  								

$	13-Dec-2018	23:43:31.256	Surface Ops Set Bellows	Optode Message																												Enable Temperature,4330,1532,Yes  								

$	13-Dec-2018	23:43:31.293	Surface Ops Set Bellows	Optode Message																												Enable HumidityComp,4330,1532,Yes  								

$	13-Dec-2018	23:43:31.326	Surface Ops Set Bellows	Optode Message																												Enable SVUformula,4330,1532,No  								

$	13-Dec-2018	23:43:31.356	Surface Ops Set Bellows	Optode Message																												Interval[s],4330,1532,30.000  								

$	13-Dec-2018	23:43:31.379	Surface Ops Set Bellows	Optode Message																												Location,4330,1532,  								

$	13-Dec-2018	23:43:31.430	Surface Ops Set Bellows	Optode Message																												Geographic Position,4330,1532,60.323605,5.37225  								

$	13-Dec-2018	23:43:31.461	Surface Ops Set Bellows	Optode Message																												Vertical Position,4330,1532,  								

$	13-Dec-2018	23:43:31.484	Surface Ops Set Bellows	Optode Message																												Reference,4330,1532,  								

$	13-Dec-2018	23:43:31.487	Surface Ops Set Bellows	Optode Message																												#  								

$	13-Dec-2018	23:43:42.371	Surface Ops Set Bellows	Normal State Exit

$	13-Dec-2018	23:43:42.376	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.004703	30.925000	156.000000																																

$	13-Dec-2018	23:43:42.591	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7260518

$	13-Dec-2018	23:43:42.694	Pre-Mission Delay	State Entry

$	13-Dec-2018	23:43:31.572	Pre-Mission Delay	SBE41 Message						   -0.13  	-0.130000	-0.120000	-0.000000	0.003333	0.001667	0.000000	3.000000																							

$	13-Dec-2018	23:43:43.128	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	144.011721	30.925000	156.000000																																

$	13-Dec-2018	23:43:34.672	Pre-Mission Delay	SBE41 Message						   -0.67  	-0.670000	-0.120026	-0.000000	0.180000	0.091667	0.000000	3.000000																							

$	13-Dec-2018	23:43:37.742	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	23:43:38.294	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	13-Dec-2018	23:43:44.159	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.670000	144.015320	30.925000	156.000000																																

$	13-Dec-2018	23:43:44.801	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.670000	144.028209	30.925000	156.000000																																

$	13-Dec-2018	23:43:40.689	Pre-Mission Delay	SBE41 Message						   -0.13  	-0.130000	-0.121405	-0.000016	-0.180000	0.000000	0.000002	3.000000																							

$	13-Dec-2018	23:43:45.930	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	144.013964	30.925000	156.000000																																

$	13-Dec-2018	23:43:43.571	Pre-Mission Delay	SBE41 Message						   -0.14  	-0.140000	-0.134251	-0.000111	0.003333	-0.088333	0.000019	3.000000																							

$	13-Dec-2018	23:43:46.571	Pre-Mission Delay	SBE41 Message						   -0.12  	-0.120000	-0.178708	-0.000068	-0.006667	-0.001667	0.000091	3.000000																							

$	13-Dec-2018	23:43:46.955	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.014291	30.925000	156.000000																																

$	13-Dec-2018	23:43:47.801	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	143.978886	30.925000	156.000000																																

$	13-Dec-2018	23:43:48.801	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.014336	30.925000	156.000000																																

$	13-Dec-2018	23:43:49.571	Pre-Mission Delay	SBE41 Message						   -0.13  	-0.130000	-0.248702	0.001402	0.003333	-0.001667	0.000245	3.000000																							

$	13-Dec-2018	23:43:49.925	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	144.026548	30.925000	156.000000																																

$	13-Dec-2018	23:43:50.801	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	144.018069	30.925000	156.000000																																

$	13-Dec-2018	23:43:51.802	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	144.019447	30.925000	156.000000																																

$	13-Dec-2018	23:43:52.572	Pre-Mission Delay	SBE41 Message						   -0.12  	-0.120000	-0.286925	0.005728	-0.003333	0.000000	0.000438	3.000000																							

$	13-Dec-2018	23:43:52.830	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.032098	30.925000	156.000000																																

$	13-Dec-2018	23:43:53.390	Pre-Mission Delay	State Timed Out

$	13-Dec-2018	23:43:53.395	Surface Ops	State Entry

$	13-Dec-2018	23:43:53.501	Surface Ops	Powering up Iridium Modem

$	13-Dec-2018	23:44:03.001	Surface Ops	Starting valve close

$	13-Dec-2018	23:44:03.005	Surface Ops	Sending SBDD2 cmd

$	13-Dec-2018	23:44:03.413	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.041412	30.925000	156.000000																																

$	13-Dec-2018	23:44:03.525	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.0014354

$	13-Dec-2018	23:43:55.571	Surface Ops	SBE41 Message						   -0.13  	-0.130000	-0.252982	0.011322	0.003333	0.000000	0.000579	3.000000																							

$	13-Dec-2018	23:43:56.619	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:03.863	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:43:56.621	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:04.074	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:43:57.620	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:04.287	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:43:57.622	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:04.503	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:43:58.571	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.185539	0.013537	-0.003333	0.000000	0.000628	3.000000																							

$	13-Dec-2018	23:43:58.622	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:04.863	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:43:58.623	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	23:44:05.075	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	23:44:05.282	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.007653	30.925000	156.000000																																

$	13-Dec-2018	23:44:05.396	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8651527

$	13-Dec-2018	23:43:58.624	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:05.608	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:43:58.626	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:05.821	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:43:59.621	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:06.033	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:43:59.630	Surface Ops	A3LA Message																																			300125060561320  	

$	13-Dec-2018	23:44:06.246	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->300125060561320  <--  

$	13-Dec-2018	23:43:59.632	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:06.458	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:43:59.634	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:06.669	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:44:00.623	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:06.882	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:00.625	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	23:44:07.094	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	23:44:00.625	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:07.307	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:00.628	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:07.522	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:44:01.570	Surface Ops	SBE41 Message						   -0.13  	-0.130000	-0.141270	0.009411	0.003333	0.000000	0.000619	3.000000																							

$	13-Dec-2018	23:44:01.624	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:07.860	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:01.626	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:08.071	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:44:08.376	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.130000	144.034609	30.925000	156.000000																																

$	13-Dec-2018	23:44:08.490	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0884764

$	13-Dec-2018	23:44:02.624	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:08.702	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:02.635	Surface Ops	A3LA Message																																			8988169234000597401  	

$	13-Dec-2018	23:44:08.915	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->8988169234000597401  <--  

$	13-Dec-2018	23:44:02.636	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:09.127	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:02.638	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:09.340	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:44:03.214	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:09.551	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:03.216	Surface Ops	A3LA Message																																			0  	

$	13-Dec-2018	23:44:09.762	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	13-Dec-2018	23:44:03.217	Surface Ops	A3LA Message																																			  	

$	13-Dec-2018	23:44:09.976	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	13-Dec-2018	23:44:03.219	Surface Ops	A3LA Message																																			OK  	

$	13-Dec-2018	23:44:10.187	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	13-Dec-2018	23:44:04.862	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.127405	0.000570	-0.010000	-0.003333	0.000590	3.000000																							

$	13-Dec-2018	23:44:07.859	Surface Ops	SBE41 Message						   -0.31  	-0.310000	-0.125225	-0.008452	0.070000	0.030000	0.000558	3.000000																							

$	13-Dec-2018	23:44:10.746	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.310000	144.032925	30.925000	156.000000																																

$	13-Dec-2018	23:44:10.858	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.2649485

$	13-Dec-2018	23:44:10.856	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.124922	-0.013005	-0.063333	0.003333	0.000526	3.000000																							

$	13-Dec-2018	23:44:11.191	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.053668	30.925000	156.000000																																

$	13-Dec-2018	23:44:12.068	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.025505	30.925000	156.000000																																

$	13-Dec-2018	23:44:13.068	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.039668	30.925000	156.000000																																

$	13-Dec-2018	23:44:13.700	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.127280	-0.011248	0.000000	-0.031667	0.000496	3.000000																							

$	13-Dec-2018	23:44:14.094	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.040704	30.925000	156.000000																																

$	13-Dec-2018	23:44:15.068	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.044757	30.925000	156.000000																																

$	13-Dec-2018	23:44:16.068	Surface Ops	PTH Message														785.525635	23.083333	54.077667	23.892744																			

$	13-Dec-2018	23:44:16.275	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.045651	30.925000	161.000000																																

$	13-Dec-2018	23:44:16.744	Surface Ops	SBE41 Message						   -0.12  	-0.120000	-0.138841	-0.005946	0.000000	0.000000	0.000480	3.000000																							

$	13-Dec-2018	23:44:16.991	Surface Ops	Processing Console Command: $go

$	13-Dec-2018	23:44:17.295	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.041210	30.925000	161.000000																																

$	13-Dec-2018	23:44:18.069	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.039996	30.925000	161.000000																																

$	13-Dec-2018	23:44:19.069	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.120000	144.063003	30.925000	161.000000																																

$	13-Dec-2018	23:44:19.867	Surface Ops	Powering up 4330 Optode

$	13-Dec-2018	23:44:21.469	Surface Ops	Sending Optode Wakeup

$	13-Dec-2018	23:44:25.476	Surface Ops	Powering up OCR504

$	13-Dec-2018	23:44:25.480	Surface Ops	Closing old .eng file: \SD\data\2018-12-13T23-41-5.eng
