$ Date Time State Comment Pressure Bel Pos Batt Volt Batt Amps CTD Temp CTD Sal Raw Press LPF Press LPF Vel Diff Vel Diff 2 Vel Slope of LPF Press. CTD Sample Period LPS331 Press LPS311 Temp SHT21 Humid SHT21 Temp PID SP PID PV PID Y1 PID Y2 PID I PID v PID u PID uCPS PID h FLBB Topt Tphase Rphase NO3 pH OCR GPS Irid Modem $ 14-Dec-2018 19:57:18.762 SM Not Running Reset Controller Status Register Value = 65792 $ 14-Dec-2018 19:57:18.767 SM Not Running File Name = \SD\data\2018-12-14T19-57-17.eng $ 14-Dec-2018 19:57:18.771 SM Not Running Volume Total Size: 7939817472 $ 14-Dec-2018 19:57:18.776 SM Not Running Volume Free Space: 7871463424 $ 14-Dec-2018 19:57:18.780 SM Not Running PlatVel PID K = 80 $ 14-Dec-2018 19:57:18.784 SM Not Running PlatVel PID Ti = 50000 $ 14-Dec-2018 19:57:18.788 SM Not Running PlatVel PID Td = 10 $ 14-Dec-2018 19:57:18.792 SM Not Running PlatVel PID Tf = 10 $ 14-Dec-2018 19:57:18.796 SM Not Running PlatVel PID Tt = 100 $ 14-Dec-2018 19:57:18.800 SM Not Running PlatVel PID B = 1 $ 14-Dec-2018 19:57:18.805 SM Not Running PlatVel PID uLow = -50 $ 14-Dec-2018 19:57:18.809 SM Not Running PlatVel PID uHigh = 50 $ 14-Dec-2018 19:57:18.813 SM Not Running PlatVel PID h = 3 $ 14-Dec-2018 19:57:18.817 SM Not Running Engr Logger Initialized $ 14-Dec-2018 19:57:19.291 SM Not Running Initializing Bluetooth Console $ 14-Dec-2018 19:57:20.296 SM Not Running Initializing GPS and synching time $ 14-Dec-2018 19:57:21.001 SM Not Running Creating Mission $ 14-Dec-2018 19:57:21.104 SM Not Running Maximum number of profiles = 10 $ 14-Dec-2018 19:57:21.208 SM Not Running Mission Timeout = 24:00:00 Mission Start Time: 12/14/2018 19:57:21 $ 14-Dec-2018 19:57:21.314 SM Not Running Recovery mode = True $ 14-Dec-2018 19:57:21.418 SM Not Running Park Sample Period = 00:01:00 $ 14-Dec-2018 19:57:21.525 SM Not Running Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7 $ 14-Dec-2018 19:57:21.632 SM Not Running Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:21.739 SM Not Running Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:21.846 SM Not Running Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:21.953 SM Not Running Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.062 SM Not Running Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.169 SM Not Running Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.276 SM Not Running Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.383 SM Not Running Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.490 SM Not Running Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.597 SM Not Running Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.704 SM Not Running Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.813 SM Not Running Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:22.920 SM Not Running Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.027 SM Not Running Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.134 SM Not Running Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.241 SM Not Running Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.348 SM Not Running Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.455 SM Not Running Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.566 SM Not Running Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.673 SM Not Running Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.780 SM Not Running Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.886 SM Not Running Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:23.995 SM Not Running Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:24.102 SM Not Running Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:24.217 SM Not Running Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:24.324 SM Not Running Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:24.433 SM Not Running Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.100, 00:00:00, 7 $ 14-Dec-2018 19:57:24.536 SM Not Running Initializing Buoyancy Engine $ 14-Dec-2018 19:57:24.638 SM Not Running Starting valve close $ 14-Dec-2018 19:57:24.645 Init Mission State Entry $ 14-Dec-2018 19:57:24.746 Init Mission Initializing FLBB $ 14-Dec-2018 19:57:29.351 Init Mission Sending FLBB stop command $ 14-Dec-2018 19:57:30.955 Init Mission Sending FLBB pkt command: $pkt 1 $ 14-Dec-2018 19:57:32.060 Init Mission Sending FLBB ave command: $ave 10 $ 14-Dec-2018 19:57:34.067 Init Mission Initializing Iridium Modem $ 14-Dec-2018 19:57:43.672 Init Mission Initializing SBE41 $ 14-Dec-2018 19:57:49.185 Init Mission Sending SBE41 stopProfile $ 14-Dec-2018 19:57:50.190 Init Mission pcutoff=1 $ 14-Dec-2018 19:57:51.194 Init Mission Sending outputPTSyes $ 14-Dec-2018 19:57:52.199 Init Mission Sending tsWait $ 14-Dec-2018 19:57:53.204 Init Mission Sending 11 bin setup commands $ 14-Dec-2018 19:57:59.732 Init Mission Initializing Optode $ 14-Dec-2018 19:58:00.334 Init Mission Sending Optode Wakeup $ 14-Dec-2018 19:58:05.341 Init Mission Initializing Pressure, Temperature, Humidity sensor $ 14-Dec-2018 19:58:05.847 Init Mission Set can pressure resolution to low $ 14-Dec-2018 19:58:05.949 Init Mission Set can pressure active $ 14-Dec-2018 19:58:05.953 Init Mission PTH Message 787.348633 21.708333 54.672760 22.637908 $ 14-Dec-2018 19:58:06.155 Init Mission Initializing MSC $ 14-Dec-2018 19:58:06.758 Init Mission MSC: OUT: INIT $ 14-Dec-2018 19:58:06.861 Init Mission Initializing Radiometer 1 $ 14-Dec-2018 19:58:07.433 Init Mission Powering down OCR504 $ 14-Dec-2018 19:58:12.437 Init Mission Powering up OCR504 $ 14-Dec-2018 19:58:17.445 Init Mission FLBB Message /99/99,99:99:99,695,2300,700,4130,539 $ 14-Dec-2018 19:57:37.674 Init Mission A3LA Message AT&D0 $ 14-Dec-2018 19:57:37.676 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:38.675 Init Mission A3LA Message AT&K0 $ 14-Dec-2018 19:57:38.677 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:39.678 Init Mission A3LA Message AT+SBDD2 $ 14-Dec-2018 19:57:39.680 Init Mission A3LA Message 0 $ 14-Dec-2018 19:57:39.681 Init Mission A3LA Message $ 14-Dec-2018 19:57:39.683 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:40.683 Init Mission A3LA Message AT+GSN $ 14-Dec-2018 19:57:40.692 Init Mission A3LA Message 300125060561320 $ 14-Dec-2018 19:57:40.693 Init Mission A3LA Message $ 14-Dec-2018 19:57:40.695 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:42.081 Init Mission A3LA Message AT+SBDC $ 14-Dec-2018 19:57:42.082 Init Mission A3LA Message 0 $ 14-Dec-2018 19:57:42.083 Init Mission A3LA Message $ 14-Dec-2018 19:58:19.282 Init Mission PTH Message 787.348633 21.625000 54.726166 22.616458 $ 14-Dec-2018 19:58:19.484 Init Mission RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 149.937831 29.175000 105.500000 $ 14-Dec-2018 19:58:19.595 Init Mission Starting valve close $ 14-Dec-2018 19:58:21.600 Init Mission Closed valve isValveOpen = false $ 14-Dec-2018 19:58:21.698 Init Mission Starting valve open $ 14-Dec-2018 19:58:23.800 Init Mission Opened valve isValveOpen = true $ 14-Dec-2018 19:58:23.899 Init Mission Starting valve close $ 14-Dec-2018 19:58:26.001 Init Mission Closed valve isValveOpen = false $ 14-Dec-2018 19:57:42.085 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:42.683 Init Mission A3LA Message ATEn=0 $ 14-Dec-2018 19:57:42.685 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:43.829 Init Mission A3LA Message $ 14-Dec-2018 19:57:43.840 Init Mission A3LA Message 8988169234000597401 $ 14-Dec-2018 19:57:43.841 Init Mission A3LA Message $ 14-Dec-2018 19:57:43.843 Init Mission A3LA Message OK $ 14-Dec-2018 19:57:49.300 Init Mission Unparsed SBE41 Message S>stopprofile $ 14-Dec-2018 19:57:50.303 Init Mission Unparsed SBE41 Message ?cmd S>pcutoff=1 $ 14-Dec-2018 19:57:51.310 Init Mission Unparsed SBE41 Message S>outputpts=y $ 14-Dec-2018 19:57:52.311 Init Mission Unparsed SBE41 Message S>tswait=2 $ 14-Dec-2018 19:57:53.323 Init Mission Unparsed SBE41 Message S>autobinavg=n $ 14-Dec-2018 19:57:53.757 Init Mission Unparsed SBE41 Message S>top_bin_interval=2 $ 14-Dec-2018 19:57:54.249 Init Mission Unparsed SBE41 Message S>top_bin_size=2 $ 14-Dec-2018 19:57:54.767 Init Mission Unparsed SBE41 Message S>top_bin_max=10 $ 14-Dec-2018 19:58:27.996 Init Mission RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 250.000000 29.175000 105.500000 $ 14-Dec-2018 19:58:28.108 Init Mission Starting valve open $ 14-Dec-2018 19:58:28.315 Init Mission Bellows inside limits $ 14-Dec-2018 19:57:55.283 Init Mission Unparsed SBE41 Message S>middle_bin_interval=2 $ 14-Dec-2018 19:57:55.775 Init Mission Unparsed SBE41 Message S>middle_bin_size=2 $ 14-Dec-2018 19:57:56.275 Init Mission Unparsed SBE41 Message S>middle_bin_max=20 $ 14-Dec-2018 19:57:56.784 Init Mission Unparsed SBE41 Message S>bottom_bin_interval=2 $ 14-Dec-2018 19:57:57.275 Init Mission Unparsed SBE41 Message S>bottom_bin_size=2 $ 14-Dec-2018 19:57:57.787 Init Mission Unparsed SBE41 Message S>includetransitionbin=n $ 14-Dec-2018 19:57:58.267 Init Mission Unparsed SBE41 Message S>includenbin=y $ 14-Dec-2018 19:58:01.385 Init Mission Optode Message *,ERROR,SYNTAX ERROR $ 14-Dec-2018 19:58:02.399 Init Mission Optode Message *,ERROR,PROTECTED PROPERTY $ 14-Dec-2018 19:58:03.409 Init Mission Optode Message *,ERROR,PROTECTED PROPERTY $ 14-Dec-2018 19:58:29.478 Init Mission MSC: RX: $ 14-Dec-2018 19:58:29.677 Init Mission MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initializing... $ 14-Dec-2018 19:58:29.780 Init Mission MSC: RX: MBARI Serial Number : 0777 $ 14-Dec-2018 19:58:29.884 Init Mission MSC: RX: CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 $ 14-Dec-2018 19:58:29.890 Init Mission MSC: RX: CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 $ 14-Dec-2018 19:58:30.089 Init Mission Radiometer Message Satlantic OCR-504 Multispectral Radiometer $ 14-Dec-2018 19:58:30.302 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 147.907823 29.175000 105.500000 $ 14-Dec-2018 19:58:31.720 Init Mission Increasing bellows position 148.663804 $ 14-Dec-2018 19:58:33.931 Init Mission Increasing bellows position 148.988560 $ 14-Dec-2018 19:58:36.142 Init Mission Increasing bellows position 149.355821 $ 14-Dec-2018 19:58:38.352 Init Mission Increasing bellows position 149.616182 $ 14-Dec-2018 19:58:40.564 Init Mission Increasing bellows position 149.807669 $ 14-Dec-2018 19:58:42.774 Init Mission Increasing bellows position 149.811015 $ 14-Dec-2018 19:58:44.985 Init Mission Increasing bellows position 149.821430 $ 14-Dec-2018 19:58:47.195 Init Mission Increasing bellows position 149.868250 $ 14-Dec-2018 19:58:49.406 Init Mission Increasing bellows position 149.872489 $ 14-Dec-2018 19:58:51.617 Init Mission Increasing bellows position 149.878979 $ 14-Dec-2018 19:58:54.129 Init Mission Decreasing bellows position 149.883933 $ 14-Dec-2018 19:58:56.340 Init Mission Decreasing bellows position 149.899490 $ 14-Dec-2018 19:58:58.550 Init Mission Decreasing bellows position 149.894051 $ 14-Dec-2018 19:59:00.762 Init Mission Decreasing bellows position 149.838269 $ 14-Dec-2018 19:59:02.972 Init Mission Decreasing bellows position 149.835363 $ 14-Dec-2018 19:59:05.183 Init Mission Decreasing bellows position 149.767824 $ 14-Dec-2018 19:59:07.393 Init Mission Decreasing bellows position 149.755739 $ 14-Dec-2018 19:59:09.604 Init Mission Decreasing bellows position 149.696283 $ 14-Dec-2018 19:59:11.822 Init Mission Decreasing bellows position 149.647556 $ 14-Dec-2018 19:59:14.033 Init Mission Decreasing bellows position 149.638675 $ 14-Dec-2018 19:59:16.042 Init Mission Radiometer Message Copyright (C) 2011, Satlantic Inc. All rights reserved. $ 14-Dec-2018 19:59:16.239 Init Mission Radiometer Message Firmware version: 5.1.0 - SatNet Type B $ 14-Dec-2018 19:59:16.252 Init Mission Radiometer Message Instrument: SATFI4 $ 14-Dec-2018 19:59:16.360 Init Mission Radiometer Message S/N: 0287 $ 14-Dec-2018 19:59:16.468 Init Mission Radiometer Message Reset Source: Power $ 14-Dec-2018 19:59:16.577 Init Mission Radiometer Message Press for command console. $ 14-Dec-2018 19:59:16.687 Init Mission Radiometer Message Initializing system. Please wait... $ 14-Dec-2018 19:59:16.893 Init Mission MSC: RX: CF Card: Size=256614400 Avail=99.05% $ 14-Dec-2018 19:59:16.996 Init Mission MSC: RX: CF2 Power Up (GMT): Thu Feb 2 02:23:24 2012 $ 14-Dec-2018 19:59:17.001 Init Mission MSC: RX: CF2 RTC Time (GMT): Thu Feb 2 02:23:28 2012 $ 14-Dec-2018 19:59:17.203 Init Mission MSC: RX: Adjusted Local Time: Wed Feb 1 18:23:28 2012 $ 14-Dec-2018 19:59:17.208 Init Mission MSC: RX: TZ Offset (GMT - LOCAL) : +8.00 hrs. $ 14-Dec-2018 19:59:17.408 Init Mission MSC: RX: RTC delta (CF2 - DS3234) : -1.00 secs. $ 14-Dec-2018 19:59:17.511 Init Mission MSC: RX: System Batt Voltage = 11.764 $ 14-Dec-2018 19:59:17.613 Init Mission MSC: RX: System Load Current = 2.62e-02 $ 14-Dec-2018 19:59:17.619 Init Mission MSC: RX: Housing Temperature = +21.27C = +70.28F $ 14-Dec-2018 19:59:17.925 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 149.551451 29.175000 105.500000 $ 14-Dec-2018 19:59:18.039 Init Mission MSC: RX: Housing Humidity = 55.7% = 12.1C (DP) $ 14-Dec-2018 19:59:18.044 Init Mission MSC: RX: Power Cycle Count = 174 $ 14-Dec-2018 19:59:18.146 Init Mission MSC: RX: System Reset Count = 178 $ 14-Dec-2018 19:59:18.249 Init Mission MSC: RX: System Error Count = 67 $ 14-Dec-2018 19:59:18.353 Init Mission MSC: RX: Last System Error = -110 $ 14-Dec-2018 19:59:18.553 Init Mission MSC: RX: Last Error Time = Wed Feb 1 06:25:09 2012 $ 14-Dec-2018 19:59:18.656 Init Mission MSC: RX: ISUS Error Count = 1 $ 14-Dec-2018 19:59:18.758 Init Mission MSC: RX: Last ISUS Error = -202 $ 14-Dec-2018 19:59:18.860 Init Mission MSC: RX: Last Error Time = Thu Jan 26 03:13:44 2012 $ 14-Dec-2018 19:59:18.964 Init Mission MSC: RX: DURA Error Count = 0 $ 14-Dec-2018 19:59:19.067 Init Mission MSC: RX: Last DURA Error = 0 $ 14-Dec-2018 19:59:19.169 Init Mission MSC: RX: Last Error Time = Thu Jan 1 00:00:00 1970 $ 14-Dec-2018 19:59:19.272 Init Mission MSC: RX: Fiberlite Odometer = 100:13:16 = 360796 secs $ 14-Dec-2018 19:59:19.277 Init Mission MSC: RX: Fiberlite Cycles = 278 $ 14-Dec-2018 19:59:19.477 Init Mission MSC: RX: Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 $ 14-Dec-2018 19:59:19.581 Init Mission MSC: RX: Zeiss Coef File Found 4 coefs loaded. $ 14-Dec-2018 19:59:19.788 Init Mission PTH Message 785.974365 21.775000 54.642242 22.702258 $ 14-Dec-2018 19:59:19.989 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 149.472132 29.100000 170.000000 $ 14-Dec-2018 19:59:20.101 Init Mission Sending SBE41 ds command $ 14-Dec-2018 19:59:20.107 Init Mission Sending ds command $ 14-Dec-2018 19:59:20.306 Init Mission MSC: RX: Ecoef File Found 256 coefs loaded. $ 14-Dec-2018 19:59:20.415 Init Mission MSC: RX: There are 73 records in the error file! $ 14-Dec-2018 19:59:20.520 Init Mission MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initialized $ 14-Dec-2018 19:59:20.526 Init Mission MSC: RX: Auto Shutdown in 10 hours at: Thu Feb 2 12:23:29 2012 $ 14-Dec-2018 19:59:20.731 Init Mission MSC: RX: Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode $ 14-Dec-2018 19:59:20.838 Init Mission Radiometer Message Autonomous operation enabled. $ 14-Dec-2018 19:58:17.988 Init Mission SBE41 Message -1.05 -1.050000 -0.000009 -0.000000 0.350000 0.175000 0.000000 3.000000 $ 14-Dec-2018 19:59:21.279 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.450436 29.100000 170.000000 $ 14-Dec-2018 19:59:21.392 Init Mission Sending SBE41 ds command $ 14-Dec-2018 19:59:21.697 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.460487 29.100000 170.000000 $ 14-Dec-2018 19:59:22.392 Init Mission Sending SBE41 ds command $ 14-Dec-2018 19:59:20.412 Init Mission Unparsed SBE41 Message S>ds $ 14-Dec-2018 19:59:20.517 Init Mission Unparsed SBE41 Message firmware compilation date: 18 December 2007 09:20 $ 14-Dec-2018 19:59:20.519 Init Mission Unparsed SBE41 Message stop profile when pressure is less than = 1.0 decibars $ 14-Dec-2018 19:59:20.624 Init Mission Unparsed SBE41 Message automatic bin averaging at end of profile disabled $ 14-Dec-2018 19:59:20.625 Init Mission Unparsed SBE41 Message number of samples = 241 $ 14-Dec-2018 19:59:20.625 Init Mission Unparsed SBE41 Message number of bins = 14 $ 14-Dec-2018 19:59:23.306 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.437532 29.100000 170.000000 $ 14-Dec-2018 19:59:23.418 Init Mission Sending SBE41 ds command $ 14-Dec-2018 19:59:20.729 Init Mission Unparsed SBE41 Message top bin interval = 2 $ 14-Dec-2018 19:59:20.729 Init Mission Unparsed SBE41 Message top bin size = 2 $ 14-Dec-2018 19:59:20.730 Init Mission Unparsed SBE41 Message top bin max = 10 $ 14-Dec-2018 19:59:20.836 Init Mission Unparsed SBE41 Message middle bin interval = 2 $ 14-Dec-2018 19:59:20.836 Init Mission Unparsed SBE41 Message middle bin size = 2 $ 14-Dec-2018 19:59:20.837 Init Mission Unparsed SBE41 Message middle bin max = 20 $ 14-Dec-2018 19:59:20.838 Init Mission Unparsed SBE41 Message bottom bin interval = 2 $ 14-Dec-2018 19:59:20.947 Init Mission Unparsed SBE41 Message bottom bin size = 2 $ 14-Dec-2018 19:59:20.948 Init Mission Unparsed SBE41 Message do not include two transition bins $ 14-Dec-2018 19:59:20.949 Init Mission Unparsed SBE41 Message include samples per bin $ 14-Dec-2018 19:59:21.075 Init Mission Unparsed SBE41 Message pumped take sample wait time = 2 sec $ 14-Dec-2018 19:59:21.076 Init Mission Unparsed SBE41 Message real-time output is PTS $ 14-Dec-2018 19:59:25.034 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.457023 29.100000 170.000000 $ 14-Dec-2018 19:59:25.149 Init Mission Sending SBE41 ds command $ 14-Dec-2018 19:59:25.356 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.446093 29.100000 170.000000 $ 14-Dec-2018 19:59:26.149 Init Mission Sending SBE41 dc command $ 14-Dec-2018 19:59:26.253 Init Mission Sending dc command $ 14-Dec-2018 19:59:26.459 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.440303 29.100000 170.000000 $ 14-Dec-2018 19:59:27.150 Init Mission Sending SBE41 dc command $ 14-Dec-2018 19:59:26.358 Init Mission Unparsed SBE41 Message S>dc $ 14-Dec-2018 19:59:26.360 Init Mission Unparsed SBE41 Message temperature: 15-mar-14 $ 14-Dec-2018 19:59:26.387 Init Mission Unparsed SBE41 Message TA0 = 3.536242e-05 $ 14-Dec-2018 19:59:26.423 Init Mission Unparsed SBE41 Message TA1 = 2.674251e-04 $ 14-Dec-2018 19:59:26.569 Init Mission Unparsed SBE41 Message TA2 = -1.901062e-06 $ 14-Dec-2018 19:59:26.570 Init Mission Unparsed SBE41 Message TA3 = 1.365250e-07 $ 14-Dec-2018 19:59:26.571 Init Mission Unparsed SBE41 Message conductivity: 15-mar-14 $ 14-Dec-2018 19:59:26.571 Init Mission Unparsed SBE41 Message G = -9.858232e-01 $ 14-Dec-2018 19:59:26.598 Init Mission Unparsed SBE41 Message H = 1.476071e-01 $ 14-Dec-2018 19:59:26.631 Init Mission Unparsed SBE41 Message I = -3.292498e-04 $ 14-Dec-2018 19:59:26.666 Init Mission Unparsed SBE41 Message J = 4.505543e-05 $ 14-Dec-2018 19:59:26.704 Init Mission Unparsed SBE41 Message CPCOR = -9.570001e-08 $ 14-Dec-2018 19:59:26.742 Init Mission Unparsed SBE41 Message CTCOR = 3.250000e-06 $ 14-Dec-2018 19:59:26.780 Init Mission Unparsed SBE41 Message WBOTC = -3.218098e-07 $ 14-Dec-2018 19:59:26.863 Init Mission Unparsed SBE41 Message pressure S/N = 4004719, range = 2900 psia: 10-mar-14 $ 14-Dec-2018 19:59:29.124 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.455063 29.100000 170.000000 $ 14-Dec-2018 19:59:29.235 Init Mission Sending SBE41 dc command $ 14-Dec-2018 19:59:26.899 Init Mission Unparsed SBE41 Message PA0 = 1.629284e-01 $ 14-Dec-2018 19:59:26.935 Init Mission Unparsed SBE41 Message PA1 = 1.404717e-01 $ 14-Dec-2018 19:59:26.971 Init Mission Unparsed SBE41 Message PA2 = -3.503310e-08 $ 14-Dec-2018 19:59:27.010 Init Mission Unparsed SBE41 Message PTCA0 = 2.758681e+01 $ 14-Dec-2018 19:59:27.049 Init Mission Unparsed SBE41 Message PTCA1 = 2.201518e-02 $ 14-Dec-2018 19:59:27.086 Init Mission Unparsed SBE41 Message PTCA2 = 1.374282e-03 $ 14-Dec-2018 19:59:27.126 Init Mission Unparsed SBE41 Message PTCB0 = 2.510888e+01 $ 14-Dec-2018 19:59:27.252 Init Mission Unparsed SBE41 Message PTCB1 = 1.175000e-03 $ 14-Dec-2018 19:59:27.253 Init Mission Unparsed SBE41 Message PTCB2 = 0.000000e+00 $ 14-Dec-2018 19:59:27.254 Init Mission Unparsed SBE41 Message PTHA0 = -7.442904e+01 $ 14-Dec-2018 19:59:27.372 Init Mission Unparsed SBE41 Message PTHA1 = 4.994783e-02 $ 14-Dec-2018 19:59:27.373 Init Mission Unparsed SBE41 Message PTHA2 = -3.966033e-07 $ 14-Dec-2018 19:59:27.373 Init Mission Unparsed SBE41 Message POFFSET = 0.000000e+00 $ 14-Dec-2018 19:59:30.970 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.456434 29.100000 170.000000 $ 14-Dec-2018 19:59:31.082 Init Mission Sending SBE41 dc command $ 14-Dec-2018 19:59:31.288 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.462268 29.100000 170.000000 $ 14-Dec-2018 19:59:32.283 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -1.050000 149.460554 29.100000 170.000000 $ 14-Dec-2018 19:59:33.081 Init Mission Sending Optode GetAll $ 14-Dec-2018 19:59:33.085 Init Mission Sending Optode Wakeup $ 14-Dec-2018 19:59:33.054 Init Mission SBE41 Message -0.14 -0.140000 -0.002224 -0.000026 -0.303333 0.023333 0.000000 3.000000 $ 14-Dec-2018 19:59:33.855 Init Mission Optode Message %!Product Name,4330,1532,Optode Sensor $ 14-Dec-2018 19:59:33.887 Init Mission Optode Message Product Number,4330,1532,4330 $ 14-Dec-2018 19:59:33.919 Init Mission Optode Message Serial Number,4330,1532,1532 $ 14-Dec-2018 19:59:33.944 Init Mission Optode Message SW ID,4330,1532,1940006 $ 14-Dec-2018 19:59:33.974 Init Mission Optode Message SW Version,4330,1532,4,8,1 $ 14-Dec-2018 19:59:34.015 Init Mission Optode Message Node Description,4330,1532,optode 1532 $ 14-Dec-2018 19:59:34.033 Init Mission Optode Message Owner,4330,1532, $ 14-Dec-2018 19:59:34.065 Init Mission Optode Message Salinity[PSU],4330,1532,0.00 $ 14-Dec-2018 19:59:34.140 Init Mission Optode Message PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00 $ 14-Dec-2018 19:59:34.166 Init Mission Optode Message FoilID,4330,1532,1206E $ 14-Dec-2018 19:59:34.385 Init Mission Optode Message FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04 $ 14-Dec-2018 19:59:34.600 Init Mission Optode Message FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00 $ 14-Dec-2018 19:59:34.683 Init Mission Optode Message FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0 $ 14-Dec-2018 19:59:38.483 Init Mission Normal State Exit $ 14-Dec-2018 19:59:38.487 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.450861 29.100000 170.000000 $ 14-Dec-2018 19:59:38.705 Init Profile State Entry $ 14-Dec-2018 19:59:38.709 Init Profile Initializing SBE 41 LPF $ 14-Dec-2018 19:59:38.918 Init Profile Sending SBE41 stopProfile $ 14-Dec-2018 19:59:39.928 Init Profile Resetting SBE41 with qsr $ 14-Dec-2018 19:59:39.932 Init Profile Sending qsr command $ 14-Dec-2018 19:59:34.766 Init Profile Optode Message FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0 $ 14-Dec-2018 19:59:34.885 Init Profile Optode Message SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00 $ 14-Dec-2018 19:59:34.933 Init Profile Optode Message ConcCoef,4330,1532,-1.549127E+00,1.068129E+00 $ 14-Dec-2018 19:59:34.971 Init Profile Optode Message NomAirPress[hPa],4330,1532,1013.25 $ 14-Dec-2018 19:59:35.001 Init Profile Optode Message NomAirMix,4330,1532,0.20946 $ 14-Dec-2018 19:59:35.041 Init Profile Optode Message CalDataSat[Deg],4330,1532,31.61,10.06 $ 14-Dec-2018 19:59:35.082 Init Profile Optode Message CalDataAPress[hPa],4330,1532,1002.000 $ 14-Dec-2018 19:59:35.125 Init Profile Optode Message CalDataZero[Deg],4330,1532,61.907,21.413 $ 14-Dec-2018 19:59:35.165 Init Profile Optode Message Mode,4330,1532,Smart Sensor Terminal $ 14-Dec-2018 19:59:35.194 Init Profile Optode Message Enable Sleep,4330,1532,Yes $ 14-Dec-2018 19:59:35.230 Init Profile Optode Message Enable Polled Mode,4330,1532,Yes $ 14-Dec-2018 19:59:35.258 Init Profile Optode Message Enable Text,4330,1532,Yes $ 14-Dec-2018 19:59:35.295 Init Profile Optode Message Enable Decimalformat,4330,1532,Yes $ 14-Dec-2018 19:59:35.343 Init Profile Optode Message Analog TempLimit[Deg.C],4330,1532,-5.00,35.00 $ 14-Dec-2018 19:59:35.393 Init Profile Optode Message Analog ConcLimit[Deg.C],4330,1532,0.00,800.00 $ 14-Dec-2018 19:59:35.441 Init Profile Optode Message Analog SatLimit[Deg.C],4330,1532,0.00,200.00 $ 14-Dec-2018 19:59:44.029 Init Profile Normal State Exit $ 14-Dec-2018 19:59:44.033 Init Profile RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.475768 29.100000 170.000000 $ 14-Dec-2018 19:59:44.248 Init Profile ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.5430926 $ 14-Dec-2018 19:59:44.253 Surface Ops Set Bellows State Entry $ 14-Dec-2018 19:59:44.458 Surface Ops Set Bellows Inflating bellows to Surface Ops position = 155.0 at 200000 cps $ 14-Dec-2018 19:59:35.490 Surface Ops Set Bellows Optode Message Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00 $ 14-Dec-2018 19:59:35.533 Surface Ops Set Bellows Optode Message Analog Output,4330,1532,O2Concentration $ 14-Dec-2018 19:59:35.586 Surface Ops Set Bellows Optode Message Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00 $ 14-Dec-2018 19:59:35.637 Surface Ops Set Bellows Optode Message Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00 $ 14-Dec-2018 19:59:35.674 Surface Ops Set Bellows Optode Message Enable AirSaturation,4330,1532,Yes $ 14-Dec-2018 19:59:35.705 Surface Ops Set Bellows Optode Message Enable Rawdata,4330,1532,Yes $ 14-Dec-2018 19:59:35.741 Surface Ops Set Bellows Optode Message Enable Temperature,4330,1532,Yes $ 14-Dec-2018 19:59:35.777 Surface Ops Set Bellows Optode Message Enable HumidityComp,4330,1532,Yes $ 14-Dec-2018 19:59:35.810 Surface Ops Set Bellows Optode Message Enable SVUformula,4330,1532,No $ 14-Dec-2018 19:59:35.842 Surface Ops Set Bellows Optode Message Interval[s],4330,1532,30.000 $ 14-Dec-2018 19:59:35.863 Surface Ops Set Bellows Optode Message Location,4330,1532, $ 14-Dec-2018 19:59:35.914 Surface Ops Set Bellows Optode Message Geographic Position,4330,1532,60.323605,5.37225 $ 14-Dec-2018 19:59:35.945 Surface Ops Set Bellows Optode Message Vertical Position,4330,1532, $ 14-Dec-2018 19:59:35.968 Surface Ops Set Bellows Optode Message Reference,4330,1532, $ 14-Dec-2018 19:59:35.971 Surface Ops Set Bellows Optode Message # $ 14-Dec-2018 19:59:46.770 Surface Ops Set Bellows Normal State Exit $ 14-Dec-2018 19:59:46.775 Surface Ops Set Bellows RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.478130 29.100000 170.000000 $ 14-Dec-2018 19:59:46.990 Surface Ops Set Bellows ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7366794 $ 14-Dec-2018 19:59:47.093 Pre-Mission Delay State Entry $ 14-Dec-2018 19:59:36.055 Pre-Mission Delay SBE41 Message -0.14 -0.140000 -0.140000 0.000000 0.000000 0.000000 0.000000 3.000000 $ 14-Dec-2018 19:59:47.529 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.473719 29.100000 170.000000 $ 14-Dec-2018 19:59:39.061 Pre-Mission Delay SBE41 Message -0.96 -0.960000 -0.140007 -0.000000 0.273333 0.136667 0.000000 3.000000 $ 14-Dec-2018 19:59:42.131 Pre-Mission Delay SBE41 Message -0.13 -0.130000 -0.141736 -0.000020 -0.276667 -0.001667 0.000002 3.000000 $ 14-Dec-2018 19:59:48.547 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 149.474546 29.100000 170.000000 $ 14-Dec-2018 19:59:49.297 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 149.479844 29.100000 170.000000 $ 14-Dec-2018 19:59:45.772 Pre-Mission Delay Unparsed SBE41 Message S> $ 14-Dec-2018 19:59:50.419 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 149.485365 29.100000 170.000000 $ 14-Dec-2018 19:59:48.113 Pre-Mission Delay SBE41 Message -0.14 -0.140000 -0.159671 -0.000163 0.003333 -0.136667 0.000026 3.000000 $ 14-Dec-2018 19:59:51.054 Pre-Mission Delay SBE41 Message -0.15 -0.150000 -0.223498 -0.000132 0.003333 0.003333 0.000129 3.000000 $ 14-Dec-2018 19:59:51.451 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.478957 29.100000 170.000000 $ 14-Dec-2018 19:59:52.297 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.478838 29.100000 170.000000 $ 14-Dec-2018 19:59:53.296 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.473958 29.100000 170.000000 $ 14-Dec-2018 19:59:54.054 Pre-Mission Delay SBE41 Message -0.14 -0.140000 -0.324298 0.001951 -0.003333 0.000000 0.000351 3.000000 $ 14-Dec-2018 19:59:54.421 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.483129 29.100000 170.000000 $ 14-Dec-2018 19:59:55.298 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.475254 29.100000 170.000000 $ 14-Dec-2018 19:59:56.297 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.469592 29.100000 170.000000 $ 14-Dec-2018 19:59:57.054 Pre-Mission Delay SBE41 Message -0.15 -0.150000 -0.377036 0.008187 0.003333 0.000000 0.000628 3.000000 $ 14-Dec-2018 19:59:57.421 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.472967 29.100000 170.000000 $ 14-Dec-2018 19:59:57.819 Pre-Mission Delay State Timed Out $ 14-Dec-2018 19:59:57.824 Surface Ops State Entry $ 14-Dec-2018 19:59:57.931 Surface Ops Powering up Iridium Modem $ 14-Dec-2018 20:00:09.001 Surface Ops Starting valve close $ 14-Dec-2018 20:00:09.102 Surface Ops Sending SBDD2 cmd $ 14-Dec-2018 20:00:09.414 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.508439 29.100000 170.000000 $ 14-Dec-2018 20:00:09.526 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.6072179 $ 14-Dec-2018 20:00:00.055 Surface Ops SBE41 Message -0.16 -0.160000 -0.323426 0.016209 0.003333 0.003333 0.000822 3.000000 $ 14-Dec-2018 20:00:01.048 Surface Ops A3LA Message $ 14-Dec-2018 20:00:09.868 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:01.050 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:10.080 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:02.048 Surface Ops A3LA Message $ 14-Dec-2018 20:00:10.293 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:02.050 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:10.505 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:03.050 Surface Ops A3LA Message $ 14-Dec-2018 20:00:10.718 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:03.052 Surface Ops A3LA Message 0 $ 14-Dec-2018 20:00:10.932 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->0 <-- $ 14-Dec-2018 20:00:03.053 Surface Ops A3LA Message $ 14-Dec-2018 20:00:11.144 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:11.353 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.160000 149.483800 29.100000 170.000000 $ 14-Dec-2018 20:00:11.465 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9332791 $ 14-Dec-2018 20:00:03.054 Surface Ops SBE41 Message -0.13 -0.130000 -0.224020 0.019176 -0.010000 -0.003333 0.000881 3.000000 $ 14-Dec-2018 20:00:03.055 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:11.802 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:04.050 Surface Ops A3LA Message $ 14-Dec-2018 20:00:12.014 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:04.058 Surface Ops A3LA Message 300125060561320 $ 14-Dec-2018 20:00:12.227 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->300125060561320 <-- $ 14-Dec-2018 20:00:04.060 Surface Ops A3LA Message $ 14-Dec-2018 20:00:12.438 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:04.062 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:12.650 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:05.051 Surface Ops A3LA Message $ 14-Dec-2018 20:00:12.867 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:05.052 Surface Ops A3LA Message 0 $ 14-Dec-2018 20:00:13.079 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->0 <-- $ 14-Dec-2018 20:00:05.053 Surface Ops A3LA Message $ 14-Dec-2018 20:00:13.292 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:05.056 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:13.503 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:06.051 Surface Ops A3LA Message $ 14-Dec-2018 20:00:13.716 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:06.053 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:13.930 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:06.055 Surface Ops SBE41 Message -0.14 -0.140000 -0.163067 0.012912 0.003333 -0.003333 0.000859 3.000000 $ 14-Dec-2018 20:00:14.360 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.506360 29.100000 170.000000 $ 14-Dec-2018 20:00:14.473 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9055734 $ 14-Dec-2018 20:00:07.052 Surface Ops A3LA Message $ 14-Dec-2018 20:00:14.685 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:07.063 Surface Ops A3LA Message 8988169234000597401 $ 14-Dec-2018 20:00:14.921 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->8988169234000597401 <-- $ 14-Dec-2018 20:00:07.064 Surface Ops A3LA Message $ 14-Dec-2018 20:00:15.134 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:07.067 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:15.347 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:09.210 Surface Ops A3LA Message $ 14-Dec-2018 20:00:15.558 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:09.210 Surface Ops A3LA Message 0 $ 14-Dec-2018 20:00:15.769 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->0 <-- $ 14-Dec-2018 20:00:09.210 Surface Ops A3LA Message $ 14-Dec-2018 20:00:15.986 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got--> <-- $ 14-Dec-2018 20:00:09.211 Surface Ops A3LA Message OK $ 14-Dec-2018 20:00:16.198 Surface Ops iModem invalid response: Looking for IModem-->AT+SBDD2<-- Got-->OK <-- $ 14-Dec-2018 20:00:10.292 Surface Ops SBE41 Message 1.75 1.750000 -0.147801 0.000062 -0.630000 -0.313333 0.000814 3.000000 $ 14-Dec-2018 20:00:13.292 Surface Ops SBE41 Message -0.68 -0.680000 -0.143424 -0.012621 0.810000 0.090000 0.000763 3.000000 $ 14-Dec-2018 20:00:16.301 Surface Ops SBE41 Message -0.15 -0.150000 -0.101826 -0.018297 -0.176667 0.316667 0.000659 3.000000 $ 14-Dec-2018 20:00:16.780 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.490960 29.100000 170.000000 $ 14-Dec-2018 20:00:16.893 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4142561 $ 14-Dec-2018 20:00:17.100 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.492279 29.100000 170.000000 $ 14-Dec-2018 20:00:18.101 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.482034 29.100000 170.000000 $ 14-Dec-2018 20:00:19.102 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.496920 29.100000 170.000000 $ 14-Dec-2018 20:00:19.212 Surface Ops SBE41 Message -0.12 -0.120000 0.037370 -0.015341 -0.010000 -0.093333 0.000385 3.000000 $ 14-Dec-2018 20:00:20.129 Surface Ops PTH Message 786.804932 22.033333 54.375214 22.863135 $ 14-Dec-2018 20:00:20.331 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.120000 149.486110 29.100000 183.500000 $ 14-Dec-2018 20:00:21.102 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.120000 149.476893 29.100000 183.500000 $ 14-Dec-2018 20:00:22.103 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.120000 149.503112 29.100000 183.500000 $ 14-Dec-2018 20:00:22.213 Surface Ops SBE41 Message -0.15 -0.150000 0.231725 -0.012324 0.010000 0.000000 -0.000119 3.000000 $ 14-Dec-2018 20:00:23.228 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.512514 29.100000 183.500000 $ 14-Dec-2018 20:00:24.104 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.490736 29.100000 183.500000 $ 14-Dec-2018 20:00:25.105 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 149.504341 29.100000 183.500000 $ 14-Dec-2018 20:00:25.215 Surface Ops SBE41 Message -0.14 -0.140000 0.288927 -0.019646 -0.003333 0.003333 -0.000668 3.000000 $ 14-Dec-2018 20:00:26.029 Surface Ops Processing Console Command: $go $ 14-Dec-2018 20:00:26.333 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.501905 29.100000 183.500000 $ 14-Dec-2018 20:00:27.105 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.492137 29.100000 183.500000 $ 14-Dec-2018 20:00:28.107 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 149.512090 29.100000 183.500000 $ 14-Dec-2018 20:00:28.904 Surface Ops Powering up 4330 Optode $ 14-Dec-2018 20:00:30.409 Surface Ops Sending Optode Wakeup $ 14-Dec-2018 20:00:34.415 Surface Ops Powering up OCR504 $ 14-Dec-2018 20:00:34.421 Surface Ops Closing old .eng file: \SD\data\2018-12-14T19-57-17.eng