$ Date Time State Comment Pressure Bel Pos Batt Volt Batt Amps CTD Temp CTD Sal Raw Press LPF Press LPF Vel Diff Vel Diff 2 Vel Slope of LPF Press. CTD Sample Period LPS331 Press LPS311 Temp SHT21 Humid SHT21 Temp PID SP PID PV PID Y1 PID Y2 PID I PID v PID u PID uCPS PID h FLBB Topt Tphase Rphase NO3 pH OCR GPS Irid Modem $ 18-Dec-2018 17:58:57.719 Surface Ops Opened new engr log file: \SD\data\2018-12-18T17-58-55.eng $ 18-Dec-2018 17:58:57.724 Surface Ops Closing old .msg file $ 18-Dec-2018 17:58:58.428 Surface Ops Opened new .msg file $ 18-Dec-2018 17:58:58.433 Surface Ops Closing old .log file $ 18-Dec-2018 17:58:58.534 Surface Ops Closing .log File $ 18-Dec-2018 17:58:59.235 Surface Ops Opened new .log file $ 18-Dec-2018 17:58:59.337 Surface Ops Profile Number = 0 $ 18-Dec-2018 17:58:59.341 Surface Ops Writing Header to msg File $ 18-Dec-2018 17:59:00.543 Surface Ops Starting Surface Optode and OCR Samples $ 18-Dec-2018 17:58:51.418 Surface Ops SBE41 Message -0.05 -0.050000 -0.356544 0.024230 0.000000 0.001667 0.000967 3.000000 $ 18-Dec-2018 17:58:52.781 Surface Ops Optode Message %!# $ 18-Dec-2018 17:58:53.787 Surface Ops Optode Message # $ 18-Dec-2018 17:58:54.417 Surface Ops SBE41 Message -0.01 -0.010000 -0.186873 0.032510 -0.013333 -0.006667 0.000758 3.000000 $ 18-Dec-2018 17:58:54.799 Surface Ops Optode Message # $ 18-Dec-2018 17:58:57.417 Surface Ops SBE41 Message -0.05 -0.050000 -0.080056 0.023007 0.013333 0.000000 0.000446 3.000000 $ 18-Dec-2018 17:59:00.417 Surface Ops SBE41 Message -0.04 -0.040000 -0.048982 0.000489 -0.003333 0.005000 0.000103 3.000000 $ 18-Dec-2018 17:59:02.692 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.869471 32.225000 160.500000 $ 18-Dec-2018 17:59:02.806 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:12.5586868 $ 18-Dec-2018 17:59:03.111 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.861081 32.225000 160.500000 $ 18-Dec-2018 17:59:03.418 Surface Ops SBE41 Message -0.05 -0.050000 -0.043646 -0.022218 0.003333 0.000000 -0.000239 3.000000 $ 18-Dec-2018 17:59:04.140 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.865537 32.225000 160.500000 $ 18-Dec-2018 17:59:05.015 Surface Ops PTH Message 766.781250 22.041667 53.551239 22.959661 $ 18-Dec-2018 17:59:05.217 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.847104 32.225000 166.000000 $ 18-Dec-2018 17:59:06.014 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.858012 32.225000 166.000000 $ 18-Dec-2018 17:59:06.419 Surface Ops SBE41 Message -0.05 -0.050000 -0.039700 -0.032858 0.000000 0.001667 -0.000540 3.000000 $ 18-Dec-2018 17:59:07.041 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.819388 32.225000 166.000000 $ 18-Dec-2018 17:59:08.015 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.860664 32.225000 166.000000 $ 18-Dec-2018 17:59:09.014 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.874328 32.225000 166.000000 $ 18-Dec-2018 17:59:09.417 Surface Ops SBE41 Message -0.04 -0.040000 -0.037077 -0.027648 -0.003333 -0.001667 -0.000694 3.000000 $ 18-Dec-2018 17:59:10.043 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.869441 32.225000 166.000000 $ 18-Dec-2018 17:59:11.015 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.864866 32.225000 166.000000 $ 18-Dec-2018 17:59:12.014 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.863287 32.225000 166.000000 $ 18-Dec-2018 17:59:12.417 Surface Ops SBE41 Message -0.04 -0.040000 -0.038659 -0.014331 0.000000 -0.001667 -0.000606 3.000000 $ 18-Dec-2018 17:59:13.041 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.857743 32.225000 166.000000 $ 18-Dec-2018 17:59:14.015 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.838297 32.225000 166.000000 $ 18-Dec-2018 17:59:15.014 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.856909 32.225000 166.000000 $ 18-Dec-2018 17:59:15.418 Surface Ops SBE41 Message -0.05 -0.050000 -0.042738 -0.004073 0.003333 0.001667 -0.000368 3.000000 $ 18-Dec-2018 17:59:16.041 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.842574 32.225000 166.000000 $ 18-Dec-2018 17:59:17.015 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.868115 32.225000 166.000000 $ 18-Dec-2018 17:59:18.014 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.857326 32.225000 166.000000 $ 18-Dec-2018 17:59:18.418 Surface Ops SBE41 Message -0.05 -0.050000 -0.045518 -0.000375 0.000000 0.001667 -0.000220 3.000000 $ 18-Dec-2018 17:59:19.041 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.862482 32.225000 166.000000 $ 18-Dec-2018 17:59:20.015 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.861811 32.225000 166.000000 $ 18-Dec-2018 17:59:20.812 Surface Ops Surface pt: $ 18-Dec-2018 17:59:20.915 Surface Ops Done with finishSurfaceOps $ 18-Dec-2018 17:59:21.219 Surface Ops Normal State Exit $ 18-Dec-2018 17:59:21.224 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.852737 32.225000 166.000000 $ 18-Dec-2018 17:59:21.812 AB Dec Buoycy Fast State Entry $ 18-Dec-2018 17:59:21.919 AB Dec Buoycy Fast Decreasing Buoyancy to pressure = 0.29999999999999999 at 200000 cps $ 18-Dec-2018 17:59:21.924 AB Dec Buoycy Fast Initializing SBE 41 LPF $ 18-Dec-2018 17:59:22.131 AB Dec Buoycy Fast Waiting 00:00:15 for sampling to finish before ABRetractFast $ 18-Dec-2018 17:59:21.489 AB Dec Buoycy Fast SBE41 Message -0.48 -0.480000 -0.050004 -0.000000 0.143333 0.071667 0.000000 3.000000 $ 18-Dec-2018 17:59:22.565 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.480000 119.869679 32.225000 166.000000 $ 18-Dec-2018 17:59:23.015 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.480000 119.856447 32.225000 166.000000 $ 18-Dec-2018 17:59:24.015 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.480000 119.850934 32.225000 166.000000 $ 18-Dec-2018 17:59:24.418 AB Dec Buoycy Fast SBE41 Message -0.05 -0.050000 -0.050910 -0.000011 -0.143333 0.000000 0.000001 3.000000 $ 18-Dec-2018 17:59:25.043 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.876862 32.225000 166.000000 $ 18-Dec-2018 17:59:26.016 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.859725 32.225000 166.000000 $ 18-Dec-2018 17:59:27.015 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.862765 32.225000 166.000000 $ 18-Dec-2018 17:59:27.418 AB Dec Buoycy Fast SBE41 Message -0.05 -0.050000 -0.060326 -0.000085 0.000000 -0.071667 0.000013 3.000000 $ 18-Dec-2018 17:59:28.042 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.844943 32.225000 166.000000 $ 18-Dec-2018 17:59:29.017 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.857967 32.225000 166.000000 $ 18-Dec-2018 17:59:30.016 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 119.864553 32.225000 166.000000 $ 18-Dec-2018 17:59:30.418 AB Dec Buoycy Fast SBE41 Message -0.06 -0.060000 -0.093911 -0.000070 0.003333 0.001667 0.000065 3.000000 $ 18-Dec-2018 17:59:31.043 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 119.856358 32.225000 166.000000 $ 18-Dec-2018 17:59:32.016 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 119.875342 32.225000 166.000000 $ 18-Dec-2018 17:59:33.017 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 119.871423 32.225000 166.000000 $ 18-Dec-2018 17:59:33.418 AB Dec Buoycy Fast SBE41 Message -0.04 -0.040000 -0.147190 0.001022 -0.006667 -0.001667 0.000178 3.000000 $ 18-Dec-2018 17:59:34.141 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.861901 32.225000 166.000000 $ 18-Dec-2018 17:59:35.017 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.858071 32.225000 166.000000 $ 18-Dec-2018 17:59:36.018 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 119.862169 32.225000 166.000000 $ 18-Dec-2018 17:59:36.417 AB Dec Buoycy Fast SBE41 Message -0.06 -0.060000 -0.175578 0.004305 0.006667 0.000000 0.000322 3.000000 $ 18-Dec-2018 17:59:37.142 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 119.864255 32.225000 166.000000 $ 18-Dec-2018 17:59:38.018 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 119.847149 32.225000 166.000000 $ 18-Dec-2018 17:59:38.815 AB Dec Buoycy Fast Disabling unneeded power $ 18-Dec-2018 17:59:38.820 AB Dec Buoycy Fast Powering down MSC $ 18-Dec-2018 17:59:38.921 AB Dec Buoycy Fast Powering down GPS $ 18-Dec-2018 17:59:39.026 AB Dec Buoycy Fast Powering down MSC $ 18-Dec-2018 17:59:39.129 AB Dec Buoycy Fast Powering down FLBB $ 18-Dec-2018 17:59:39.230 AB Dec Buoycy Fast Powering down 4330 Optode $ 18-Dec-2018 17:59:39.332 AB Dec Buoycy Fast Powering down OCR504 $ 18-Dec-2018 17:59:39.435 AB Dec Buoycy Fast Powering down Bluetooth $ 18-Dec-2018 17:59:42.538 AB Dec Buoycy Fast Powering down BT Module $ 18-Dec-2018 17:59:39.533 AB Dec Buoycy Fast SBE41 Message 5.28 5.280000 -0.147924 0.008554 -1.780000 -0.886667 0.000426 3.000000 $ 18-Dec-2018 17:59:42.417 AB Dec Buoycy Fast SBE41 Message 1.42 1.420000 -0.084093 0.010304 1.286667 -0.246667 0.000446 3.000000 $ 18-Dec-2018 17:59:43.093 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.420000 119.864091 32.225000 166.000000 $ 18-Dec-2018 17:59:43.204 AB Dec Buoycy Fast ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.3884812 $ 18-Dec-2018 17:59:43.210 AB Dec Buoycy Fast Starting valve open $ 18-Dec-2018 17:59:45.117 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.420000 119.881809 32.225000 166.000000 $ 18-Dec-2018 17:59:45.229 AB Dec Buoycy Fast ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0191534 $ 18-Dec-2018 17:59:45.535 AB Dec Buoycy Fast RecMode true, PID Off, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.420000 119.878262 32.225000 166.000000 $ 18-Dec-2018 17:59:46.339 AB Dec Buoycy Fast AB Decreasing Buoyancy Fast Exiting: Depth > pressure threshold $ 18-Dec-2018 17:59:45.418 AB Dec Buoycy Fast SBE41 Message 1.30 1.300000 0.069120 0.008016 0.040000 0.663333 0.000274 3.000000 $ 18-Dec-2018 17:59:46.770 AB Dec Buoycy Fast Normal State Exit $ 18-Dec-2018 17:59:46.775 AB Dec Buoycy Fast RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.300000 119.894192 32.225000 166.000000 $ 18-Dec-2018 17:59:47.332 Descend State Entry $ 18-Dec-2018 17:59:47.344 Descend Starting valve open $ 18-Dec-2018 17:59:47.759 Descend RecMode true, PID On, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.300000 119.904995 32.225000 166.000000 $ 18-Dec-2018 17:59:48.537 Descend RecMode true, PID On, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.300000 119.897768 32.225000 166.000000 $ 18-Dec-2018 17:59:48.417 Descend Vel PID Values -0.200000 0.280000 0.028315 0.028315 -0.001096 -25.815730 -25.815730 -211482.000000 3.000000 $ 18-Dec-2018 17:59:48.417 Descend SBE41 Message 0.46 0.460000 0.529947 0.001317 0.280000 0.160000 -0.000464 3.000000 $ 18-Dec-2018 17:59:49.876 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.460000 119.907007 32.225000 166.000000 $ 18-Dec-2018 17:59:50.535 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.460000 119.895756 32.225000 166.000000 $ 18-Dec-2018 17:59:51.536 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.460000 119.930759 32.225000 166.000000 $ 18-Dec-2018 17:59:51.418 Descend Vel PID Values -0.200000 0.006667 0.042033 0.013718 -0.002258 -23.021826 -23.021826 -188594.000000 3.000000 $ 18-Dec-2018 17:59:51.418 Descend SBE41 Message 0.44 0.440000 1.336380 -0.018861 0.006667 0.143333 -0.002182 3.000000 $ 18-Dec-2018 17:59:52.875 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.440000 120.155945 32.225000 166.000000 $ 18-Dec-2018 17:59:53.535 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.440000 120.462000 32.225000 166.000000 $ 18-Dec-2018 17:59:54.536 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.440000 120.625705 32.225000 166.000000 $ 18-Dec-2018 17:59:54.418 Descend Vel PID Values -0.200000 0.000000 0.045489 0.003456 -0.003436 -20.563026 -20.563026 -168452.000000 3.000000 $ 18-Dec-2018 17:59:54.418 Descend SBE41 Message 0.44 0.440000 1.985718 -0.066571 0.000000 0.003333 -0.004642 3.000000 $ 18-Dec-2018 17:59:55.876 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.440000 120.789498 32.225000 166.000000 $ 18-Dec-2018 17:59:56.537 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.440000 120.976597 32.225000 166.000000 $ 18-Dec-2018 17:59:57.538 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.440000 121.121034 32.225000 166.000000 $ 18-Dec-2018 17:59:57.418 Descend Vel PID Values -0.200000 -0.436667 -0.001327 -0.046816 -0.004390 -3.413137 -3.413137 -27960.000000 3.000000 $ 18-Dec-2018 17:59:57.418 Descend SBE41 Message 1.75 1.750000 1.952156 -0.132240 -0.436667 -0.218333 -0.006946 3.000000 $ 18-Dec-2018 17:59:58.877 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.750000 121.344715 32.225000 166.000000 $ 18-Dec-2018 17:59:59.538 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.750000 121.555552 32.225000 166.000000 $ 18-Dec-2018 18:00:00.538 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.750000 121.563330 32.225000 166.000000 $ 18-Dec-2018 18:00:00.419 Descend Vel PID Values -0.200000 -0.013333 -0.028842 -0.027515 -0.005211 -6.359701 -6.359701 -52098.000000 3.000000 $ 18-Dec-2018 18:00:00.419 Descend SBE41 Message 1.79 1.790000 1.400707 -0.173855 -0.013333 -0.225000 -0.008433 3.000000 $ 18-Dec-2018 18:00:01.878 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.790000 121.566936 32.225000 166.000000 $ 18-Dec-2018 18:00:02.539 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.790000 121.588558 32.225000 166.000000 $ 18-Dec-2018 18:00:03.539 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.790000 121.633425 32.225000 166.000000 $ 18-Dec-2018 18:00:03.418 Descend Vel PID Values -0.200000 -0.336667 -0.075428 -0.046586 -0.005809 2.452031 2.452031 20087.000000 3.000000 $ 18-Dec-2018 18:00:03.418 Descend SBE41 Message 2.80 2.800000 0.889753 -0.153282 -0.336667 -0.175000 -0.009181 3.000000 $ 18-Dec-2018 18:00:04.879 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.800000 121.714950 32.225000 166.000000 $ 18-Dec-2018 18:00:05.539 Descend PTH Message 766.294189 22.000000 53.467316 23.045461 $ 18-Dec-2018 18:00:05.742 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.800000 121.833682 32.100000 126.000000 $ 18-Dec-2018 18:00:06.540 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.800000 121.825665 32.100000 126.000000 $ 18-Dec-2018 18:00:06.416 Descend Vel PID Values -0.200000 -0.036667 -0.097680 -0.022252 -0.006300 -2.257414 -2.257414 -18492.000000 3.000000 $ 18-Dec-2018 18:00:06.416 Descend SBE41 Message 2.91 2.910000 0.737334 -0.070802 -0.036667 -0.186667 -0.009672 3.000000 $ 18-Dec-2018 18:00:07.881 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.910000 121.836096 32.100000 126.000000 $ 18-Dec-2018 18:00:08.541 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.910000 121.839494 32.100000 126.000000 $ 18-Dec-2018 18:00:09.541 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.910000 121.830478 32.100000 126.000000 $ 18-Dec-2018 18:00:09.418 Descend Vel PID Values -0.200000 -0.310000 -0.131652 -0.033972 -0.006628 3.585037 3.585037 29368.000000 3.000000 $ 18-Dec-2018 18:00:09.418 Descend SBE41 Message 3.84 3.840000 0.960634 0.033272 -0.310000 -0.173333 -0.010397 3.000000 $ 18-Dec-2018 18:00:10.880 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.840000 121.843785 32.100000 126.000000 $ 18-Dec-2018 18:00:11.541 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.840000 121.853262 32.100000 126.000000 $ 18-Dec-2018 18:00:12.542 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 3.840000 121.837184 32.100000 126.000000 $ 18-Dec-2018 18:00:12.418 Descend Vel PID Values -0.200000 -0.126667 -0.150233 -0.018581 -0.006867 0.967013 0.967013 7921.000000 3.000000 $ 18-Dec-2018 18:00:12.418 Descend SBE41 Message 4.22 4.220000 1.436831 0.098401 -0.126667 -0.218333 -0.011667 3.000000 $ 18-Dec-2018 18:00:13.881 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.220000 121.846169 32.100000 126.000000 $ 18-Dec-2018 18:00:14.542 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.220000 121.842936 32.100000 126.000000 $ 18-Dec-2018 18:00:15.543 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.220000 121.827081 32.100000 126.000000 $ 18-Dec-2018 18:00:15.418 Descend Vel PID Values -0.200000 -0.256667 -0.171435 -0.021202 -0.007004 3.361746 3.361746 27539.000000 3.000000 $ 18-Dec-2018 18:00:15.418 Descend SBE41 Message 4.99 4.990000 2.004870 0.083119 -0.256667 -0.191667 -0.013572 3.000000 $ 18-Dec-2018 18:00:16.881 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.990000 121.838346 32.100000 126.000000 $ 18-Dec-2018 18:00:17.543 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.990000 121.837482 32.100000 126.000000 $ 18-Dec-2018 18:00:18.544 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 4.990000 121.851712 32.100000 126.000000 $ 18-Dec-2018 18:00:18.418 Descend Vel PID Values -0.200000 -0.180000 -0.184212 -0.012777 -0.007080 2.137244 2.137244 17508.000000 3.000000 $ 18-Dec-2018 18:00:18.418 Descend SBE41 Message 5.53 5.530000 2.572672 0.001722 -0.180000 -0.218333 -0.016074 3.000000 $ 18-Dec-2018 18:00:19.885 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 5.530000 121.829480 32.100000 126.000000 $ 18-Dec-2018 18:00:20.544 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 5.530000 121.855348 32.100000 126.000000 $ 18-Dec-2018 18:00:21.545 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 5.530000 121.836215 32.100000 126.000000 $ 18-Dec-2018 18:00:21.418 Descend Vel PID Values -0.200000 -0.240000 -0.197032 -0.012820 -0.007094 3.174056 3.174056 26001.000000 3.000000 $ 18-Dec-2018 18:00:21.418 Descend SBE41 Message 6.25 6.250000 3.137120 -0.091743 -0.240000 -0.210000 -0.019131 3.000000 $ 18-Dec-2018 18:00:22.886 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.250000 121.838480 32.100000 126.000000 $ 18-Dec-2018 18:00:23.545 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.250000 121.833026 32.100000 126.000000 $ 18-Dec-2018 18:00:24.545 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.250000 121.834606 32.100000 126.000000 $ 18-Dec-2018 18:00:24.418 Descend Vel PID Values -0.200000 -0.160000 -0.200489 -0.003457 -0.007092 0.953978 0.953978 7814.000000 3.000000 $ 18-Dec-2018 18:00:24.418 Descend SBE41 Message 6.73 6.730000 3.718975 -0.156801 -0.160000 -0.200000 -0.022725 3.000000 $ 18-Dec-2018 18:00:25.886 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.730000 121.847078 32.100000 126.000000 $ 18-Dec-2018 18:00:26.546 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.730000 121.862978 32.100000 126.000000 $ 18-Dec-2018 18:00:27.546 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 6.730000 121.852204 32.100000 126.000000 $ 18-Dec-2018 18:00:27.418 Descend Vel PID Values -0.200000 -0.193333 -0.201708 -0.001219 -0.007084 0.454509 0.454509 3723.000000 3.000000 $ 18-Dec-2018 18:00:27.418 Descend SBE41 Message 7.31 7.310000 4.322954 -0.188043 -0.193333 -0.176667 -0.026843 3.000000 $ 18-Dec-2018 18:00:28.884 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.310000 121.856108 32.100000 126.000000 $ 18-Dec-2018 18:00:29.547 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.310000 121.848613 32.100000 126.000000 $ 18-Dec-2018 18:00:30.548 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.310000 121.825457 32.100000 126.000000 $ 18-Dec-2018 18:00:30.418 Descend Vel PID Values -0.200000 -0.213333 -0.203568 -0.001860 -0.007067 0.774427 0.774427 6344.000000 3.000000 $ 18-Dec-2018 18:00:30.418 Descend SBE41 Message 7.95 7.950000 4.941367 -0.198059 -0.213333 -0.203333 -0.031458 3.000000 $ 18-Dec-2018 18:00:31.887 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.950000 121.864676 32.100000 126.000000 $ 18-Dec-2018 18:00:32.547 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.950000 121.843338 32.100000 126.000000 $ 18-Dec-2018 18:00:33.547 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 7.950000 121.846780 32.100000 126.000000 $ 18-Dec-2018 18:00:33.418 Descend Vel PID Values -0.200000 -0.216667 -0.205938 -0.002370 -0.007038 1.099866 1.099866 9010.000000 3.000000 $ 18-Dec-2018 18:00:33.418 Descend SBE41 Message 8.60 8.600000 5.561183 -0.200771 -0.216667 -0.215000 -0.036526 3.000000 $ 18-Dec-2018 18:00:34.888 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 8.600000 121.834949 32.100000 126.000000 $ 18-Dec-2018 18:00:35.548 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 8.600000 121.845543 32.100000 126.000000 $ 18-Dec-2018 18:00:36.548 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 8.600000 121.848807 32.100000 126.000000 $ 18-Dec-2018 18:00:36.418 Descend Vel PID Values -0.200000 -0.196666 -0.206332 -0.000394 -0.007008 0.604472 0.604472 4951.000000 3.000000 $ 18-Dec-2018 18:00:36.418 Descend SBE41 Message 9.19 9.190000 6.167287 -0.204171 -0.196666 -0.206667 -0.041979 3.000000 $ 18-Dec-2018 18:00:37.889 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.190000 121.821001 32.100000 126.000000 $ 18-Dec-2018 18:00:38.549 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.190000 121.833429 32.100000 126.000000 $ 18-Dec-2018 18:00:39.550 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.190000 121.845290 32.100000 126.000000 $ 18-Dec-2018 18:00:39.418 Descend Vel PID Values -0.200000 -0.193334 -0.205238 0.001093 -0.006983 0.120535 0.120535 987.000000 3.000000 $ 18-Dec-2018 18:00:39.418 Descend SBE41 Message 9.77 9.770000 6.757657 -0.208403 -0.193334 -0.195000 -0.047751 3.000000 $ 18-Dec-2018 18:00:40.889 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.770000 121.860504 32.100000 126.000000 $ 18-Dec-2018 18:00:41.551 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.770000 121.817321 32.100000 126.000000 $ 18-Dec-2018 18:00:42.551 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 9.770000 121.822029 32.100000 126.000000 $ 18-Dec-2018 18:00:42.420 Descend Vel PID Values -0.200000 -0.210000 -0.205106 0.000133 -0.006958 0.366090 0.366090 2999.000000 3.000000 $ 18-Dec-2018 18:00:42.420 Descend SBE41 Message 10.40 10.400000 7.349744 -0.210449 -0.210000 -0.201667 -0.053796 3.000000 $ 18-Dec-2018 18:00:43.893 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 10.400000 121.832788 32.100000 126.000000 $ 18-Dec-2018 18:00:44.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 10.400000 121.846169 32.100000 126.000000 $ 18-Dec-2018 18:00:45.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 10.400000 121.825725 32.100000 126.000000 $ 18-Dec-2018 18:00:45.419 Descend Vel PID Values -0.200000 -0.233334 -0.207886 -0.002780 -0.006920 1.365219 1.365219 11183.000000 3.000000 $ 18-Dec-2018 18:00:45.419 Descend SBE41 Message 11.10 11.100000 7.957249 -0.209543 -0.233334 -0.221667 -0.060087 3.000000 $ 18-Dec-2018 18:00:46.897 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.100000 121.828675 32.100000 126.000000 $ 18-Dec-2018 18:00:47.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.100000 121.839121 32.100000 126.000000 $ 18-Dec-2018 18:00:48.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.100000 121.843889 32.100000 126.000000 $ 18-Dec-2018 18:00:48.419 Descend Vel PID Values -0.200000 -0.206667 -0.209324 -0.001439 -0.006876 1.122615 1.122615 9196.000000 3.000000 $ 18-Dec-2018 18:00:48.419 Descend SBE41 Message 11.72 11.720000 8.572824 -0.207580 -0.206667 -0.220000 -0.066585 3.000000 $ 18-Dec-2018 18:00:49.892 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.720000 121.853471 32.100000 126.000000 $ 18-Dec-2018 18:00:50.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.720000 121.841222 32.100000 126.000000 $ 18-Dec-2018 18:00:51.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 11.720000 121.850997 32.100000 126.000000 $ 18-Dec-2018 18:00:51.419 Descend Vel PID Values -0.200000 -0.180000 -0.207167 0.002157 -0.006841 -0.008777 -0.008777 -71.000000 3.000000 $ 18-Dec-2018 18:00:51.419 Descend SBE41 Message 12.26 12.260000 9.185546 -0.206558 -0.180000 -0.193333 -0.073239 3.000000 $ 18-Dec-2018 18:00:52.890 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.260000 121.829659 32.100000 126.000000 $ 18-Dec-2018 18:00:53.552 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.260000 121.834606 32.100000 126.000000 $ 18-Dec-2018 18:00:54.551 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.260000 121.838704 32.100000 126.000000 $ 18-Dec-2018 18:00:54.418 Descend Vel PID Values -0.200000 -0.193333 -0.204556 0.002611 -0.006819 -0.338571 -0.338571 -2773.000000 3.000000 $ 18-Dec-2018 18:00:54.418 Descend SBE41 Message 12.84 12.840000 9.800824 -0.207087 -0.193333 -0.186667 -0.080002 3.000000 $ 18-Dec-2018 18:00:55.890 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.840000 121.856615 32.100000 126.000000 $ 18-Dec-2018 18:00:56.552 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.840000 121.847272 32.100000 126.000000 $ 18-Dec-2018 18:00:57.551 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 12.840000 121.842891 32.100000 126.000000 $ 18-Dec-2018 18:00:57.419 Descend Vel PID Values -0.200000 -0.210000 -0.203640 0.000916 -0.006802 0.040038 0.040038 327.000000 3.000000 $ 18-Dec-2018 18:00:57.419 Descend SBE41 Message 13.47 13.470000 10.428471 -0.208774 -0.210000 -0.201667 -0.086844 3.000000 $ 18-Dec-2018 18:00:58.891 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 13.470000 121.857405 32.100000 126.000000 $ 18-Dec-2018 18:00:59.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 13.470000 121.841744 32.100000 126.000000 $ 18-Dec-2018 18:01:00.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 13.470000 121.864453 32.100000 126.000000 $ 18-Dec-2018 18:01:00.419 Descend Vel PID Values -0.200000 -0.216667 -0.204442 -0.000803 -0.006780 0.562608 0.562608 4608.000000 3.000000 $ 18-Dec-2018 18:01:00.419 Descend SBE41 Message 14.12 14.120000 11.060203 -0.210957 -0.216667 -0.213333 -0.093722 3.000000 $ 18-Dec-2018 18:01:01.893 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.120000 121.833384 32.100000 126.000000 $ 18-Dec-2018 18:01:02.553 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.120000 121.829867 32.100000 126.000000 $ 18-Dec-2018 18:01:03.552 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.120000 121.846005 32.100000 126.000000 $ 18-Dec-2018 18:01:03.420 Descend Vel PID Values -0.200000 -0.206667 -0.205118 -0.000676 -0.006756 0.582889 0.582889 4775.000000 3.000000 $ 18-Dec-2018 18:01:03.420 Descend SBE41 Message 14.74 14.740000 11.676419 -0.212983 -0.206667 -0.211667 -0.100568 3.000000 $ 18-Dec-2018 18:01:04.895 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.740000 121.847332 32.100000 126.000000 $ 18-Dec-2018 18:01:05.552 Descend PTH Message 767.108154 22.166667 53.314728 23.077637 $ 18-Dec-2018 18:01:05.755 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.740000 121.849209 32.175000 116.000000 $ 18-Dec-2018 18:01:06.553 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 14.740000 121.842220 32.175000 116.000000 $ 18-Dec-2018 18:01:06.419 Descend Vel PID Values -0.200000 -0.200000 -0.204980 0.000138 -0.006732 0.354897 0.354897 2907.000000 3.000000 $ 18-Dec-2018 18:01:06.419 Descend SBE41 Message 15.34 15.340000 12.274124 -0.214235 -0.200000 -0.203333 -0.107316 3.000000 $ 18-Dec-2018 18:01:07.893 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.340000 121.821299 32.175000 116.000000 $ 18-Dec-2018 18:01:08.553 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.340000 121.838093 32.175000 116.000000 $ 18-Dec-2018 18:01:09.553 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.340000 121.839255 32.175000 116.000000 $ 18-Dec-2018 18:01:09.419 Descend Vel PID Values -0.200000 -0.196667 -0.204062 0.000918 -0.006713 0.073394 0.073394 601.000000 3.000000 $ 18-Dec-2018 18:01:09.419 Descend SBE41 Message 15.93 15.930000 12.871608 -0.214174 -0.196667 -0.198333 -0.113922 3.000000 $ 18-Dec-2018 18:01:10.892 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.930000 121.849746 32.175000 116.000000 $ 18-Dec-2018 18:01:11.553 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.930000 121.827126 32.175000 116.000000 $ 18-Dec-2018 18:01:12.553 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 15.930000 121.856779 32.175000 116.000000 $ 18-Dec-2018 18:01:12.419 Descend Vel PID Values -0.200000 -0.200000 -0.203136 0.000927 -0.006697 -0.002960 -0.002960 -24.000000 3.000000 $ 18-Dec-2018 18:01:12.419 Descend SBE41 Message 16.53 16.530001 13.483719 -0.212668 -0.200000 -0.198333 -0.120365 3.000000 $ 18-Dec-2018 18:01:13.893 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 16.530001 121.844843 32.175000 116.000000 $ 18-Dec-2018 18:01:14.553 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 16.530001 121.848747 32.175000 116.000000 $ 18-Dec-2018 18:01:15.554 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 16.530001 121.853173 32.175000 116.000000 $ 18-Dec-2018 18:01:15.419 Descend Vel PID Values -0.200000 -0.199999 -0.202298 0.000838 -0.006686 -0.046252 -0.046252 -378.000000 3.000000 $ 18-Dec-2018 18:01:15.419 Descend SBE41 Message 17.13 17.129999 14.105914 -0.210467 -0.199999 -0.200000 -0.126617 3.000000 $ 18-Dec-2018 18:01:16.894 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.129999 121.842504 32.175000 116.000000 $ 18-Dec-2018 18:01:17.554 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.129999 121.827677 32.175000 116.000000 $ 18-Dec-2018 18:01:18.555 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.129999 121.837839 32.175000 116.000000 $ 18-Dec-2018 18:01:18.419 Descend Vel PID Values -0.200000 -0.206667 -0.202269 0.000029 -0.006676 0.167161 0.167161 1369.000000 3.000000 $ 18-Dec-2018 18:01:18.419 Descend SBE41 Message 17.75 17.750000 14.724479 -0.209018 -0.206667 -0.203333 -0.132636 3.000000 $ 18-Dec-2018 18:01:19.895 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.750000 121.863857 32.175000 116.000000 $ 18-Dec-2018 18:01:20.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.750000 121.853888 32.175000 116.000000 $ 18-Dec-2018 18:01:21.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 17.750000 121.825963 32.175000 116.000000 $ 18-Dec-2018 18:01:21.418 Descend Vel PID Values -0.200000 -0.206667 -0.202698 -0.000429 -0.006663 0.323415 0.323415 2649.000000 3.000000 $ 18-Dec-2018 18:01:21.418 Descend SBE41 Message 18.37 18.370001 15.332565 -0.209299 -0.206667 -0.206667 -0.139176 3.000000 $ 18-Dec-2018 18:01:22.893 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 18.370001 121.859238 32.175000 116.000000 $ 18-Dec-2018 18:01:23.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 18.370001 121.847689 32.175000 116.000000 $ 18-Dec-2018 18:01:24.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 18.370001 121.841446 32.175000 116.000000 $ 18-Dec-2018 18:01:24.419 Descend Vel PID Values -0.200000 -0.210000 -0.203677 -0.000979 -0.006645 0.548594 0.548594 4494.000000 3.000000 $ 18-Dec-2018 18:01:24.419 Descend SBE41 Message 19.00 19.000000 15.933479 -0.210722 -0.210000 -0.208333 -0.145502 3.000000 $ 18-Dec-2018 18:01:25.893 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.000000 121.828213 32.175000 116.000000 $ 18-Dec-2018 18:01:26.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.000000 121.852607 32.175000 116.000000 $ 18-Dec-2018 18:01:27.554 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.000000 121.833101 32.175000 116.000000 $ 18-Dec-2018 18:01:27.419 Descend Vel PID Values -0.200000 -0.216667 -0.205540 -0.001864 -0.006618 0.933570 0.933570 7647.000000 3.000000 $ 18-Dec-2018 18:01:27.419 Descend SBE41 Message 19.65 19.650000 16.534392 -0.211584 -0.216667 -0.213333 -0.151549 3.000000 $ 18-Dec-2018 18:01:28.895 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.650000 121.853083 32.175000 116.000000 $ 18-Dec-2018 18:01:29.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.650000 121.856734 32.175000 116.000000 $ 18-Dec-2018 18:01:30.554 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 19.650000 121.860832 32.175000 116.000000 $ 18-Dec-2018 18:01:30.418 Descend Vel PID Values -0.200000 -0.230000 -0.209061 -0.003520 -0.006575 1.657044 1.657044 13574.000000 3.000000 $ 18-Dec-2018 18:01:30.418 Descend SBE41 Message 20.34 20.340000 17.140802 -0.210854 -0.230000 -0.223333 -0.157255 3.000000 $ 18-Dec-2018 18:01:31.895 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.340000 121.861503 32.175000 116.000000 $ 18-Dec-2018 18:01:32.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.340000 121.854872 32.175000 116.000000 $ 18-Dec-2018 18:01:33.554 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.340000 121.852428 32.175000 116.000000 $ 18-Dec-2018 18:01:33.419 Descend Vel PID Values -0.200000 -0.193333 -0.209448 -0.000387 -0.006530 0.852581 0.852581 6984.000000 3.000000 $ 18-Dec-2018 18:01:33.419 Descend SBE41 Message 20.92 20.920000 17.755367 -0.209197 -0.193333 -0.211667 -0.162564 3.000000 $ 18-Dec-2018 18:01:34.894 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.920000 121.846050 32.175000 116.000000 $ 18-Dec-2018 18:01:35.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.920000 121.837795 32.175000 116.000000 $ 18-Dec-2018 18:01:36.554 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 20.920000 121.841148 32.175000 116.000000 $ 18-Dec-2018 18:01:36.418 Descend Vel PID Values -0.200000 -0.180000 -0.206688 0.002760 -0.006497 -0.207584 -0.207584 -1700.000000 3.000000 $ 18-Dec-2018 18:01:36.418 Descend SBE41 Message 21.46 21.459999 18.379700 -0.208119 -0.180000 -0.186666 -0.167478 3.000000 $ 18-Dec-2018 18:01:37.893 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 21.459999 121.852294 32.175000 116.000000 $ 18-Dec-2018 18:01:38.555 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 21.459999 121.836752 32.175000 116.000000 $ 18-Dec-2018 18:01:39.554 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 21.459999 121.851146 32.175000 116.000000 $ 18-Dec-2018 18:01:39.420 Descend Vel PID Values -0.200000 -0.200000 -0.204461 0.002227 -0.006476 -0.243505 -0.243505 -1994.000000 3.000000 $ 18-Dec-2018 18:01:39.420 Descend SBE41 Message 22.06 22.059999 19.014890 -0.208573 -0.200000 -0.190000 -0.172011 3.000000 $ 18-Dec-2018 18:01:40.894 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.059999 121.854916 32.175000 116.000000 $ 18-Dec-2018 18:01:41.554 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.059999 121.862352 32.175000 116.000000 $ 18-Dec-2018 18:01:42.555 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.059999 121.860474 32.175000 116.000000 $ 18-Dec-2018 18:01:42.418 Descend Vel PID Values -0.200000 -0.220000 -0.204781 -0.000320 -0.006453 0.461403 0.461403 3779.000000 3.000000 $ 18-Dec-2018 18:01:42.418 Descend SBE41 Message 22.72 22.719999 19.655623 -0.210606 -0.220000 -0.210000 -0.176237 3.000000 $ 18-Dec-2018 18:01:43.897 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.719999 121.834576 32.175000 116.000000 $ 18-Dec-2018 18:01:44.555 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.719999 121.846095 32.175000 116.000000 $ 18-Dec-2018 18:01:45.556 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.719999 121.846542 32.175000 116.000000 $ 18-Dec-2018 18:01:45.418 Descend Vel PID Values -0.200000 -0.203334 -0.204815 -0.000034 -0.006430 0.387653 0.387653 3175.000000 3.000000 $ 18-Dec-2018 18:01:45.418 Descend SBE41 Message 23.33 23.330000 20.286226 -0.213655 -0.203334 -0.211667 -0.180195 3.000000 $ 18-Dec-2018 18:01:46.895 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.330000 121.851623 32.175000 116.000000 $ 18-Dec-2018 18:01:47.556 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.330000 121.848255 32.175000 116.000000 $ 18-Dec-2018 18:01:48.556 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.330000 121.835515 32.175000 116.000000 $ 18-Dec-2018 18:01:48.419 Descend Vel PID Values -0.200000 -0.200000 -0.204347 0.000468 -0.006409 0.216489 0.216489 1773.000000 3.000000 $ 18-Dec-2018 18:01:48.419 Descend SBE41 Message 23.93 23.930000 20.894506 -0.216543 -0.200000 -0.201667 -0.184221 3.000000 $ 18-Dec-2018 18:01:49.895 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.930000 121.834338 32.175000 116.000000 $ 18-Dec-2018 18:01:50.556 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.930000 121.863618 32.175000 116.000000 $ 18-Dec-2018 18:01:51.556 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.930000 121.855259 32.175000 116.000000 $ 18-Dec-2018 18:01:51.418 Descend Vel PID Values -0.200000 -0.203334 -0.203981 0.000365 -0.006390 0.214652 0.214652 1758.000000 3.000000 $ 18-Dec-2018 18:01:51.418 Descend SBE41 Message 24.54 24.540001 21.489317 -0.217691 -0.203334 -0.201667 -0.188732 3.000000 $ 18-Dec-2018 18:01:52.896 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.540001 121.859059 32.175000 116.000000 $ 18-Dec-2018 18:01:53.556 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.540001 121.856317 32.175000 116.000000 $ 18-Dec-2018 18:01:54.557 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.540001 121.855021 32.175000 116.000000 $ 18-Dec-2018 18:01:54.419 Descend Vel PID Values -0.200000 -0.203333 -0.203710 0.000271 -0.006372 0.218219 0.218219 1787.000000 3.000000 $ 18-Dec-2018 18:01:54.419 Descend SBE41 Message 25.15 25.150000 22.090584 -0.216251 -0.203333 -0.203333 -0.193548 3.000000 $ 18-Dec-2018 18:01:55.896 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.150000 121.861085 32.175000 116.000000 $ 18-Dec-2018 18:01:56.557 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.150000 121.849641 32.175000 116.000000 $ 18-Dec-2018 18:01:57.558 Descend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.150000 121.852785 32.175000 116.000000 $ 18-Dec-2018 18:01:57.419 Descend Vel PID Values -0.200000 -0.173333 -0.200486 0.003224 -0.006370 -0.827186 -0.827186 -6776.000000 3.000000 $ 18-Dec-2018 18:01:57.419 Descend SBE41 Message 25.67 25.670000 22.704180 -0.213034 -0.173333 -0.188333 -0.197813 3.000000 $ 18-Dec-2018 18:01:58.898 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.670000 121.843338 32.175000 116.000000 $ 18-Dec-2018 18:01:59.558 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.670000 121.845126 32.175000 116.000000 $ 18-Dec-2018 18:02:00.557 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.670000 121.852964 32.175000 116.000000 $ 18-Dec-2018 18:02:00.419 Descend Vel PID Values -0.200000 -0.006667 -0.179075 0.021411 -0.006470 -7.389922 -7.389922 -60538.000000 3.000000 $ 18-Dec-2018 18:02:00.419 Descend SBE41 Message 25.69 25.690001 23.320258 -0.209914 -0.006667 -0.090000 -0.200824 3.000000 $ 18-Dec-2018 18:02:01.896 Descend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.690001 121.851534 32.175000 116.000000 $ 18-Dec-2018 18:02:02.856 Descend Starting valve close $ 18-Dec-2018 18:02:02.860 Descend Descend glide on $ 18-Dec-2018 18:02:03.266 Descend RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.690001 121.837124 32.175000 116.000000 $ 18-Dec-2018 18:02:03.378 Descend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0231109 $ 18-Dec-2018 18:02:03.483 Descend SBE41 Message 25.68 25.680000 23.928645 -0.208436 0.003333 -0.001667 -0.202535 3.000000 $ 18-Dec-2018 18:02:03.810 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.838987 32.175000 116.000000 $ 18-Dec-2018 18:02:04.588 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.834323 32.175000 116.000000 $ 18-Dec-2018 18:02:05.588 Descend PTH Message 768.741455 22.308333 53.177399 23.141987 $ 18-Dec-2018 18:02:05.790 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.840999 32.200000 107.000000 $ 18-Dec-2018 18:02:06.385 Descend Bottom detected based on Platform Velocity near zero $ 18-Dec-2018 18:02:06.491 Descend SBE41 Message 25.68 25.680000 24.512887 -0.208967 0.000000 0.001667 -0.203322 3.000000 $ 18-Dec-2018 18:02:06.822 Descend Normal State Exit $ 18-Dec-2018 18:02:06.826 Descend RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.849656 32.200000 107.000000 $ 18-Dec-2018 18:02:07.385 Anchor State Entry $ 18-Dec-2018 18:02:07.487 Anchor Starting valve close $ 18-Dec-2018 18:02:07.495 Anchor Powering up MSC $ 18-Dec-2018 18:02:07.598 Anchor Powering up FLBB $ 18-Dec-2018 18:02:09.298 Anchor Sending FLBB stop command $ 18-Dec-2018 18:02:10.803 Anchor Sending FLBB pkt command: $pkt 1 $ 18-Dec-2018 18:02:11.906 Anchor Sending FLBB ave command: $ave 10 $ 18-Dec-2018 18:02:12.911 Anchor Powering up 4330 Optode $ 18-Dec-2018 18:02:14.416 Anchor Sending Optode Wakeup $ 18-Dec-2018 18:02:18.422 Anchor Powering up OCR504 $ 18-Dec-2018 18:02:18.539 Anchor Starting anchor period = 00:04:00 $ 18-Dec-2018 18:02:18.988 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.840522 32.200000 107.000000 $ 18-Dec-2018 18:02:19.100 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:11.7141180 $ 18-Dec-2018 18:02:09.418 Anchor SBE41 Message 25.67 25.670000 25.025197 -0.210268 0.003333 0.001667 -0.203551 3.000000 $ 18-Dec-2018 18:02:19.232 Anchor MSC: RX: $ 18-Dec-2018 18:02:19.432 Anchor MSC: RX: $ 18-Dec-2018 18:02:19.534 Anchor MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initializing... $ 18-Dec-2018 18:02:12.487 Anchor SBE41 Message 25.46 25.459999 25.396112 -0.208996 0.070000 0.036667 -0.203321 3.000000 $ 18-Dec-2018 18:02:13.188 Anchor Optode Message % $ 18-Dec-2018 18:02:13.299 Anchor Optode Message StartupInfo,4330,1532,Mode,AADI Smart Sensor Terminal Protocol,RS232 Protocol Version,3,Config Version,11 $ 18-Dec-2018 18:02:20.189 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.459999 121.849239 32.200000 107.000000 $ 18-Dec-2018 18:02:20.300 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1951399 $ 18-Dec-2018 18:02:20.403 Anchor MSC: RX: MBARI Serial Number : 0777 $ 18-Dec-2018 18:02:20.507 Anchor MSC: RX: CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 $ 18-Dec-2018 18:02:20.512 Anchor MSC: RX: CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 $ 18-Dec-2018 18:02:20.713 Anchor MSC: RX: CF Card: Size=256614400 Avail=99.01% $ 18-Dec-2018 18:02:20.815 Anchor MSC: RX: CF2 Power Up (GMT): Mon Feb 6 00:27:41 2012 $ 18-Dec-2018 18:02:20.821 Anchor MSC: RX: CF2 RTC Time (GMT): Mon Feb 6 00:27:45 2012 $ 18-Dec-2018 18:02:21.023 Anchor MSC: RX: Adjusted Local Time: Sun Feb 5 16:27:45 2012 $ 18-Dec-2018 18:02:21.032 Anchor MSC: RX: TZ Offset (GMT - LOCAL) : +8.00 hrs. $ 18-Dec-2018 18:02:21.135 Anchor MSC: RX: RTC delta (CF2 - DS3234) : +0.00 secs. $ 18-Dec-2018 18:02:21.335 Anchor MSC: RX: System Batt Voltage = 11.760 $ 18-Dec-2018 18:02:21.437 Anchor MSC: RX: System Load Current = 2.62e-02 $ 18-Dec-2018 18:02:15.494 Anchor SBE41 Message 25.20 25.200001 25.594720 -0.199878 0.086666 0.078333 -0.202562 3.000000 $ 18-Dec-2018 18:02:15.496 Anchor Optode Message !# $ 18-Dec-2018 18:02:21.680 Anchor MSC: RX: Housing Temperature = +21.08C = +69.94F $ 18-Dec-2018 18:02:21.880 Anchor MSC: RX: Housing Humidity = 56.0% = 12.0C (DP) $ 18-Dec-2018 18:02:22.087 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.200001 121.842012 32.200000 107.000000 $ 18-Dec-2018 18:02:22.200 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8945262 $ 18-Dec-2018 18:02:22.304 Anchor MSC: RX: Power Cycle Count = 196 $ 18-Dec-2018 18:02:22.309 Anchor MSC: RX: System Reset Count = 200 $ 18-Dec-2018 18:02:22.509 Anchor MSC: RX: System Error Count = 76 $ 18-Dec-2018 18:02:22.611 Anchor MSC: RX: Last System Error = -110 $ 18-Dec-2018 18:02:22.713 Anchor MSC: RX: Last Error Time = Sun Feb 5 05:21:54 2012 $ 18-Dec-2018 18:02:22.818 Anchor MSC: RX: ISUS Error Count = 1 $ 18-Dec-2018 18:02:22.920 Anchor MSC: RX: Last ISUS Error = -202 $ 18-Dec-2018 18:02:23.023 Anchor MSC: RX: Last Error Time = Thu Jan 26 03:13:44 2012 $ 18-Dec-2018 18:02:23.126 Anchor MSC: RX: DURA Error Count = 0 $ 18-Dec-2018 18:02:23.131 Anchor MSC: RX: Last DURA Error = 0 $ 18-Dec-2018 18:02:23.233 Anchor MSC: RX: Last Error Time = Thu Jan 1 00:00:00 1970 $ 18-Dec-2018 18:02:23.435 Anchor MSC: RX: Fiberlite Odometer = 100:14:05 = 360845 secs $ 18-Dec-2018 18:02:23.538 Anchor MSC: RX: Fiberlite Cycles = 296 $ 18-Dec-2018 18:02:23.543 Anchor MSC: RX: Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 $ 18-Dec-2018 18:02:23.646 Anchor MSC: RX: Zeiss Coef File Found 4 coefs loaded. $ 18-Dec-2018 18:02:23.847 Anchor MSC: RX: Ecoef File Found 256 coefs loaded. $ 18-Dec-2018 18:02:24.053 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.200001 121.835291 32.200000 107.000000 $ 18-Dec-2018 18:02:24.167 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9611481 $ 18-Dec-2018 18:02:24.270 Anchor MSC: RX: There are 82 records in the error file! $ 18-Dec-2018 18:02:24.275 Anchor MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initialized $ 18-Dec-2018 18:02:16.544 Anchor Optode Message # $ 18-Dec-2018 18:02:24.494 Anchor MSC: RX: Auto Shutdown in 10 hours at: Mon Feb 6 10:27:46 2012 $ 18-Dec-2018 18:02:24.694 Anchor MSC: RX: Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode $ 18-Dec-2018 18:02:17.464 Anchor Optode Message # $ 18-Dec-2018 18:02:18.419 Anchor SBE41 Message 25.19 25.190001 25.658757 -0.178087 0.003333 0.045000 -0.201155 3.000000 $ 18-Dec-2018 18:02:24.935 Anchor Radiometer Message Satlantic OCR-504 Multispectral Radiometer $ 18-Dec-2018 18:02:25.145 Anchor Radiometer Message Copyright (C) 2011, Satlantic Inc. All rights reserved. $ 18-Dec-2018 18:02:25.156 Anchor Radiometer Message Firmware version: 5.1.0 - SatNet Type B $ 18-Dec-2018 18:02:25.266 Anchor Radiometer Message Instrument: SATFI4 $ 18-Dec-2018 18:02:25.376 Anchor Radiometer Message S/N: 0287 $ 18-Dec-2018 18:02:25.582 Anchor Radiometer Message Reset Source: Power $ 18-Dec-2018 18:02:25.593 Anchor Radiometer Message Press for command console. $ 18-Dec-2018 18:02:25.903 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.190001 121.848866 32.200000 107.000000 $ 18-Dec-2018 18:02:26.015 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8434661 $ 18-Dec-2018 18:02:26.021 Anchor Radiometer Message Initializing system. Please wait... $ 18-Dec-2018 18:02:21.540 Anchor SBE41 Message 25.19 25.190001 25.642354 -0.142878 0.000000 0.001667 -0.198975 3.000000 $ 18-Dec-2018 18:02:26.253 Anchor Radiometer Message Autonomous operation enabled. $ 18-Dec-2018 18:02:24.475 Anchor SBE41 Message 25.17 25.170000 25.565758 -0.098904 0.006667 0.003333 -0.196060 3.000000 $ 18-Dec-2018 18:02:26.791 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 121.844500 32.200000 107.000000 $ 18-Dec-2018 18:02:27.224 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 121.834606 32.200000 107.000000 $ 18-Dec-2018 18:02:27.419 Anchor SBE41 Message 25.90 25.900000 25.442273 -0.053799 -0.243333 -0.118333 -0.192421 3.000000 $ 18-Dec-2018 18:02:28.348 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.836513 32.200000 107.000000 $ 18-Dec-2018 18:02:29.225 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.839806 32.200000 107.000000 $ 18-Dec-2018 18:02:30.225 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.839091 32.200000 107.000000 $ 18-Dec-2018 18:02:30.419 Anchor SBE41 Message 25.87 25.870001 25.316784 -0.014728 0.010000 -0.116667 -0.188100 3.000000 $ 18-Dec-2018 18:02:31.348 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.870001 121.837094 32.200000 107.000000 $ 18-Dec-2018 18:02:32.225 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.870001 121.849269 32.200000 107.000000 $ 18-Dec-2018 18:02:33.225 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.870001 121.844083 32.200000 107.000000 $ 18-Dec-2018 18:02:33.418 Anchor SBE41 Message 25.86 25.860001 25.248855 0.013782 0.003333 0.006667 -0.183217 3.000000 $ 18-Dec-2018 18:02:34.251 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.860001 121.827945 32.200000 107.000000 $ 18-Dec-2018 18:02:35.226 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.860001 121.851861 32.200000 107.000000 $ 18-Dec-2018 18:02:36.226 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.860001 121.846020 32.200000 107.000000 $ 18-Dec-2018 18:02:36.419 Anchor SBE41 Message 25.06 25.059999 25.284259 0.030207 0.266667 0.135000 -0.177924 3.000000 $ 18-Dec-2018 18:02:37.350 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 121.836975 32.200000 107.000000 $ 18-Dec-2018 18:02:38.227 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 121.838480 32.200000 107.000000 $ 18-Dec-2018 18:02:39.227 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 121.843427 32.200000 107.000000 $ 18-Dec-2018 18:02:39.420 Anchor SBE41 Message 25.06 25.059999 25.430682 0.033862 0.000000 0.133334 -0.172369 3.000000 $ 18-Dec-2018 18:02:40.253 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 121.848077 32.200000 107.000000 $ 18-Dec-2018 18:02:41.227 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 121.832997 32.200000 107.000000 $ 18-Dec-2018 18:02:42.227 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.059999 121.848136 32.200000 107.000000 $ 18-Dec-2018 18:02:42.419 Anchor SBE41 Message 25.07 25.070000 25.611176 0.023166 -0.003333 -0.001667 -0.166625 3.000000 $ 18-Dec-2018 18:02:43.351 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.070000 121.842846 32.200000 107.000000 $ 18-Dec-2018 18:02:44.228 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.070000 121.845007 32.200000 107.000000 $ 18-Dec-2018 18:02:45.228 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.070000 121.836483 32.200000 107.000000 $ 18-Dec-2018 18:02:45.419 Anchor SBE41 Message 25.95 25.950001 25.681399 -0.000128 -0.293334 -0.148334 -0.160603 3.000000 $ 18-Dec-2018 18:02:46.351 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.820226 32.200000 107.000000 $ 18-Dec-2018 18:02:47.228 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.848330 32.200000 107.000000 $ 18-Dec-2018 18:02:48.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.842280 32.200000 107.000000 $ 18-Dec-2018 18:02:48.419 Anchor SBE41 Message 25.94 25.940001 25.567095 -0.025004 0.003333 -0.145000 -0.154122 3.000000 $ 18-Dec-2018 18:02:49.374 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.866792 32.200000 107.000000 $ 18-Dec-2018 18:02:50.228 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.851340 32.200000 107.000000 $ 18-Dec-2018 18:02:51.228 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.855035 32.200000 107.000000 $ 18-Dec-2018 18:02:51.419 Anchor SBE41 Message 25.12 25.120001 25.368160 -0.035063 0.273333 0.138333 -0.147122 3.000000 $ 18-Dec-2018 18:02:52.354 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.120001 121.835858 32.200000 107.000000 $ 18-Dec-2018 18:02:53.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.120001 121.851817 32.200000 107.000000 $ 18-Dec-2018 18:02:54.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.120001 121.847972 32.200000 107.000000 $ 18-Dec-2018 18:02:54.419 Anchor SBE41 Message 25.03 25.030001 25.277333 -0.021957 0.030000 0.151667 -0.139787 3.000000 $ 18-Dec-2018 18:02:55.255 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.030001 121.837541 32.200000 107.000000 $ 18-Dec-2018 18:02:56.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.030001 121.834829 32.200000 107.000000 $ 18-Dec-2018 18:02:57.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.030001 121.846333 32.200000 107.000000 $ 18-Dec-2018 18:02:57.419 Anchor SBE41 Message 25.02 25.020000 25.376208 0.005190 0.003333 0.016667 -0.132408 3.000000 $ 18-Dec-2018 18:02:58.257 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.840373 32.200000 107.000000 $ 18-Dec-2018 18:02:59.229 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.831968 32.200000 107.000000 $ 18-Dec-2018 18:03:00.230 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.854901 32.200000 107.000000 $ 18-Dec-2018 18:03:00.419 Anchor SBE41 Message 25.96 25.959999 25.527611 0.025199 -0.313333 -0.155000 -0.125088 3.000000 $ 18-Dec-2018 18:03:01.354 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.835053 32.200000 107.000000 $ 18-Dec-2018 18:03:02.231 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.843293 32.200000 107.000000 $ 18-Dec-2018 18:03:03.231 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.847957 32.200000 107.000000 $ 18-Dec-2018 18:03:04.036 Anchor CTD post: 25.95 NaN NaN $ 18-Dec-2018 18:03:03.419 Anchor SBE41 Message 25.95 25.950001 25.530141 0.023026 0.003333 -0.155000 -0.117656 3.000000 $ 18-Dec-2018 18:03:04.459 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.841267 32.200000 107.000000 $ 18-Dec-2018 18:03:04.749 Anchor Sending CTD PTS $ 18-Dec-2018 18:03:04.753 Anchor Sci Logger sample CTD pts $ 18-Dec-2018 18:03:04.859 Anchor Sending Optode Do Sample $ 18-Dec-2018 18:03:04.962 Anchor Sending Optode Wakeup $ 18-Dec-2018 18:03:04.855 Anchor Unparsed SBE41 Message S>pts $ 18-Dec-2018 18:03:05.385 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.855155 32.200000 107.000000 $ 18-Dec-2018 18:03:05.564 Anchor Sci Logger sample Optode $ 18-Dec-2018 18:03:05.581 Anchor Sci Logger sample pH and NO3 $ 18-Dec-2018 18:03:05.732 Anchor Sending FLBB run command $ 18-Dec-2018 18:03:05.833 Anchor Sci Logger sample FLBB $ 18-Dec-2018 18:03:05.938 Anchor Sending radiometer pollSample $ 18-Dec-2018 18:03:06.040 Anchor Sci Logger sample Radiometer $ 18-Dec-2018 18:03:06.142 Anchor Starting ISUS sample $ 18-Dec-2018 18:03:06.345 Anchor Starting MSC Sequence CTDValues (time, press, temp, salinity) 0, 0.00, 0.000, 0.00 $ 18-Dec-2018 18:03:06.351 Anchor MSC: OUT: W $ 18-Dec-2018 18:03:06.801 Anchor MSC: OUT: W $ 18-Dec-2018 18:03:06.905 Anchor Radiometer Message SATFI40287,-0.0046,-0.0031,-0.0064,-0.1659 $ 18-Dec-2018 18:03:07.020 Anchor Radiometer post: SATFI40287,-0.0046,-0.0031,-0.0064,-0.1659 $ 18-Dec-2018 18:03:07.026 Anchor MSC: RX: $ 18-Dec-2018 18:03:06.656 Anchor Optode Message 4330,1532,271.404,21.512,29.280,29.212,36.285,7.073,529.3,466.4,142.4 $ 18-Dec-2018 18:03:07.342 Anchor Optode post: 4330,1532,271.404,21.512,29.280,29.212,36.285,7.073,529.3,466.4,142.4 $ 18-Dec-2018 18:03:06.659 Anchor Optode Message # $ 18-Dec-2018 18:03:07.461 Anchor MSC: RX: $ 18-Dec-2018 18:03:07.563 Anchor FLBB Message /99/99,99:99:99,695,2316,700,4130,537 $ 18-Dec-2018 18:03:07.771 Anchor FLBB post: /99/99,99:99:99,695,2316,700,4130,537 $ 18-Dec-2018 18:03:07.978 Anchor PTH Message 768.440674 22.358333 53.062958 23.184888 $ 18-Dec-2018 18:03:08.182 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.848002 32.175000 147.500000 $ 18-Dec-2018 18:03:08.293 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1550839 $ 18-Dec-2018 18:03:08.396 Anchor MSC: RX: ACK $ 18-Dec-2018 18:03:08.401 Anchor MSC: Got ACK $ 18-Dec-2018 18:03:08.704 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.859610 32.175000 147.500000 $ 18-Dec-2018 18:03:09.502 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.844292 32.175000 147.500000 $ 18-Dec-2018 18:03:10.301 Anchor MSC: OUT: CTD,0,0.0000,0.0000,0.0000 $ 18-Dec-2018 18:03:10.615 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.860787 32.175000 147.500000 $ 18-Dec-2018 18:03:11.300 Anchor MSC: RX: NAK,CTD,EConvertErr: 0 $ 18-Dec-2018 18:03:11.402 Anchor MSC: EConvertErr: 0 $ 18-Dec-2018 18:03:11.706 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.858224 32.175000 147.500000 $ 18-Dec-2018 18:03:11.955 Anchor SBE41 Message 25.02, 21.4969, 37.9081 25.020000 25.380109 0.004613 0.310000 0.156666 -0.108786 3.000000 $ 18-Dec-2018 18:03:12.632 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.853679 32.175000 147.500000 $ 18-Dec-2018 18:03:13.300 Anchor MSC: OUT: W $ 18-Dec-2018 18:03:13.652 Anchor MSC: OUT: W $ 18-Dec-2018 18:03:13.755 Anchor MSC: RX: ACK $ 18-Dec-2018 18:03:13.856 Anchor MSC: Got ACK $ 18-Dec-2018 18:03:14.062 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.868700 32.175000 147.500000 $ 18-Dec-2018 18:03:14.299 Anchor MSC: OUT: MODE,1 $ 18-Dec-2018 18:03:14.404 Anchor MSC: RX: ACK $ 18-Dec-2018 18:03:14.408 Anchor MSC: Got ACK $ 18-Dec-2018 18:03:14.809 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.865183 32.175000 147.500000 $ 18-Dec-2018 18:03:15.299 Anchor MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:03:14.952 Anchor Unparsed SBE41 Message S> $ 18-Dec-2018 18:03:15.623 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.865273 32.175000 147.500000 $ 18-Dec-2018 18:03:16.298 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:03:16.603 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.860296 32.175000 147.500000 $ 18-Dec-2018 18:03:17.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.842086 32.175000 147.500000 $ 18-Dec-2018 18:03:18.297 Anchor MSC: OUT: TS $ 18-Dec-2018 18:03:17.419 Anchor SBE41 Message 25.95 25.950001 25.280238 -0.009436 -0.310000 0.000000 -0.099476 3.000000 $ 18-Dec-2018 18:03:18.631 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.857181 32.175000 147.500000 $ 18-Dec-2018 18:03:19.298 Anchor MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:03:19.504 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.844664 32.175000 147.500000 $ 18-Dec-2018 18:03:20.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.869087 32.175000 147.500000 $ 18-Dec-2018 18:03:20.417 Anchor SBE41 Message 25.98 25.980000 25.365899 -0.006472 -0.010000 -0.160000 -0.090640 3.000000 $ 18-Dec-2018 18:03:21.527 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.980000 121.844620 32.175000 147.500000 $ 18-Dec-2018 18:03:22.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.980000 121.838480 32.175000 147.500000 $ 18-Dec-2018 18:03:23.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.980000 121.835619 32.175000 147.500000 $ 18-Dec-2018 18:03:23.419 Anchor SBE41 Message 25.01 25.010000 25.533940 0.005615 0.323333 0.156667 -0.082380 3.000000 $ 18-Dec-2018 18:03:24.529 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.848091 32.175000 147.500000 $ 18-Dec-2018 18:03:25.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.855289 32.175000 147.500000 $ 18-Dec-2018 18:03:26.298 Anchor MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:03:26.604 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.868849 32.175000 147.500000 $ 18-Dec-2018 18:03:26.419 Anchor SBE41 Message 25.01 25.010000 25.622004 0.009927 0.000000 0.161667 -0.074571 3.000000 $ 18-Dec-2018 18:03:27.527 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.859416 32.175000 147.500000 $ 18-Dec-2018 18:03:28.298 Anchor MSC: OUT: SL $ 18-Dec-2018 18:03:28.603 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.861607 32.175000 147.500000 $ 18-Dec-2018 18:03:29.299 Anchor MSC: RX: 0x5FA8,A,02/06/2012 00:28:53,0,-1.00,-1.0000,-1.0000,293,196,1,76,21.09,56.01,11.572,5.306e-01,10887.00,2260.00,1123.60,13.20,-20.44,-191.56,3.398e-02,17,87,4AFC4982474E44D2426140413EE13E7C3F22405D4279458F49C84F22550B5BE463166A3370B5766E7A947CC57D5D7C23797175C8717E6D20692C65BD63366188609D60A661CE63A0663569916DAF729C77E27DE183E289E08FBE94E799349C2C9DC29D8D9BBA986593638DAA8730805679D473636D7D6848637E5F5F5BD858FF5694549152E951BF510650AA50B3,6841.6 $ 18-Dec-2018 18:03:29.409 Anchor MSC: Data: 0x5FA8,A,02/06/2012 00:28:53,0,-1.00,-1.0000,-1.0000,293,196,1,76,21.09,56.01,11.572,5.306e-01,10887.00,2260.00,1123.60,13.20,-20.44,-191.56,3.398e-02,17,87,4AFC4982474E44D2426140413EE13E7C3F22405D4279458F49C84F22550B5BE463166A3370B5766E7A947CC57D5D7C23797175C8717E6D20692C65BD63366188609D60A661CE63A0663569916DAF729C77E27DE183E289E08FBE94E799349C2C9DC29D8D9BBA986593638DAA8730805679D473636D7D6848637E5F5F5BD858FF5694549152E951BF510650AA50B3,6841.6 $ 18-Dec-2018 18:03:29.521 Anchor MSC post: -191.56 $ 18-Dec-2018 18:03:29.520 Anchor SBE41 Message 25.01 25.010000 25.634099 -0.000536 0.000000 0.000000 -0.067086 3.000000 $ 18-Dec-2018 18:03:29.852 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.837631 32.175000 147.500000 $ 18-Dec-2018 18:03:30.298 Anchor MSC: Done Sampling. $ 18-Dec-2018 18:03:30.302 Anchor Starting pH sample $ 18-Dec-2018 18:03:30.501 Anchor MSC: OUT: W $ 18-Dec-2018 18:03:30.756 Anchor MSC: OUT: W $ 18-Dec-2018 18:03:30.859 Anchor MSC: RX: ACK $ 18-Dec-2018 18:03:30.863 Anchor MSC: Got ACK $ 18-Dec-2018 18:03:31.166 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.862397 32.175000 147.500000 $ 18-Dec-2018 18:03:31.300 Anchor MSC: OUT: MODE,2 $ 18-Dec-2018 18:03:31.404 Anchor MSC: RX: ACK $ 18-Dec-2018 18:03:31.408 Anchor MSC: Got ACK $ 18-Dec-2018 18:03:31.809 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.860608 32.175000 147.500000 $ 18-Dec-2018 18:03:32.300 Anchor MSC: RX: ACK,MODE,2 $ 18-Dec-2018 18:03:32.604 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.860847 32.175000 147.500000 $ 18-Dec-2018 18:03:33.299 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:03:32.420 Anchor SBE41 Message 25.97 25.969999 25.624331 -0.018296 -0.320000 -0.160000 -0.059922 3.000000 $ 18-Dec-2018 18:03:33.631 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.861309 32.175000 147.500000 $ 18-Dec-2018 18:03:34.502 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.869266 32.175000 147.500000 $ 18-Dec-2018 18:03:35.299 Anchor MSC: OUT: TS $ 18-Dec-2018 18:03:35.604 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.841833 32.175000 147.500000 $ 18-Dec-2018 18:03:35.418 Anchor SBE41 Message 25.95 25.950001 25.532849 -0.029241 0.006666 -0.156667 -0.052976 3.000000 $ 18-Dec-2018 18:03:36.326 Anchor MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:03:36.728 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.846646 32.175000 147.500000 $ 18-Dec-2018 18:03:37.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.843204 32.175000 147.500000 $ 18-Dec-2018 18:03:38.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.870205 32.175000 147.500000 $ 18-Dec-2018 18:03:38.418 Anchor SBE41 Message 25.00 25.000000 25.352470 -0.022523 0.316667 0.161667 -0.046166 3.000000 $ 18-Dec-2018 18:03:39.625 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.851504 32.175000 147.500000 $ 18-Dec-2018 18:03:40.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.853784 32.175000 147.500000 $ 18-Dec-2018 18:03:41.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.853143 32.175000 147.500000 $ 18-Dec-2018 18:03:41.418 Anchor SBE41 Message 24.99 24.990000 25.252247 0.000192 0.003333 0.160000 -0.039623 3.000000 $ 18-Dec-2018 18:03:42.624 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.841967 32.175000 147.500000 $ 18-Dec-2018 18:03:43.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.845856 32.175000 147.500000 $ 18-Dec-2018 18:03:44.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.852294 32.175000 147.500000 $ 18-Dec-2018 18:03:44.417 Anchor SBE41 Message 24.99 24.990000 25.347929 0.023591 0.000000 0.001667 -0.033604 3.000000 $ 18-Dec-2018 18:03:45.423 Anchor MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:03:45.727 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.855959 32.175000 147.500000 $ 18-Dec-2018 18:03:46.501 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.841788 32.175000 147.500000 $ 18-Dec-2018 18:03:47.298 Anchor MSC: OUT: SL $ 18-Dec-2018 18:03:47.604 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.859297 32.175000 147.500000 $ 18-Dec-2018 18:03:47.420 Anchor SBE41 Message 25.98 25.980000 25.502812 0.031532 -0.330000 -0.165000 -0.028191 3.000000 $ 18-Dec-2018 18:03:48.422 Anchor MSC: RX: 0xC796,pH,02/06/2012 00:29:15,0,-1.00,-1.0000,-1.0000,312,196,0,21.09,56.03,11.744,4.660e-02,7.1234,0.000,-1.032813,0.000930,-1.025384,0.001060,+3.331e-09,+1.020e-09 $ 18-Dec-2018 18:03:48.528 Anchor MSC: Data: 0xC796,pH,02/06/2012 00:29:15,0,-1.00,-1.0000,-1.0000,312,196,0,21.09,56.03,11.744,4.660e-02,7.1234,0.000,-1.032813,0.000930,-1.025384,0.001060,+3.331e-09,+1.020e-09 $ 18-Dec-2018 18:03:48.634 Anchor MSC post: 7.1234 $ 18-Dec-2018 18:03:48.937 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.980000 121.832773 32.175000 147.500000 $ 18-Dec-2018 18:03:49.297 Anchor MSC: Done Sampling. $ 18-Dec-2018 18:03:49.301 Anchor MSC: OUT: SLP $ 18-Dec-2018 18:03:49.704 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.980000 121.834308 32.175000 147.500000 $ 18-Dec-2018 18:03:50.299 Anchor MSC: RX: ACK,SLP $ 18-Dec-2018 18:03:50.602 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.980000 121.842995 32.175000 147.500000 $ 18-Dec-2018 18:03:50.419 Anchor SBE41 Message 25.97 25.969999 25.498263 0.021020 0.003333 -0.163333 -0.023213 3.000000 $ 18-Dec-2018 18:03:51.527 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.851280 32.175000 147.500000 $ 18-Dec-2018 18:03:52.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.861577 32.175000 147.500000 $ 18-Dec-2018 18:03:53.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.852338 32.175000 147.500000 $ 18-Dec-2018 18:03:53.419 Anchor SBE41 Message 25.04 25.040001 25.336300 0.002775 0.309999 0.156666 -0.018501 3.000000 $ 18-Dec-2018 18:03:54.526 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.040001 121.845916 32.175000 147.500000 $ 18-Dec-2018 18:03:55.498 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.040001 121.863633 32.175000 147.500000 $ 18-Dec-2018 18:03:56.499 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.040001 121.853545 32.175000 147.500000 $ 18-Dec-2018 18:03:56.420 Anchor SBE41 Message 25.02 25.020000 25.238611 -0.008280 0.006667 0.158333 -0.014134 3.000000 $ 18-Dec-2018 18:03:57.525 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.840209 32.175000 147.500000 $ 18-Dec-2018 18:03:58.497 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.846244 32.175000 147.500000 $ 18-Dec-2018 18:03:59.499 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.865898 32.175000 147.500000 $ 18-Dec-2018 18:03:59.419 Anchor SBE41 Message 25.02 25.020000 25.341206 -0.004535 0.000000 0.003333 -0.010343 3.000000 $ 18-Dec-2018 18:04:00.623 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.847928 32.175000 147.500000 $ 18-Dec-2018 18:04:01.499 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.856615 32.175000 147.500000 $ 18-Dec-2018 18:04:02.500 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.856958 32.175000 147.500000 $ 18-Dec-2018 18:04:02.419 Anchor SBE41 Message 25.97 25.969999 25.508250 0.006448 -0.316666 -0.158333 -0.007219 3.000000 $ 18-Dec-2018 18:04:03.525 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.866181 32.175000 147.500000 $ 18-Dec-2018 18:04:03.754 Anchor Unparsed SBE41 Message S> $ 18-Dec-2018 18:04:04.616 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.858910 32.175000 147.500000 $ 18-Dec-2018 18:04:04.749 Anchor Sending CTD PTS $ 18-Dec-2018 18:04:04.753 Anchor Sci Logger sample CTD pts $ 18-Dec-2018 18:04:04.957 Anchor Sending Optode Do Sample $ 18-Dec-2018 18:04:04.961 Anchor Sending Optode Wakeup $ 18-Dec-2018 18:04:04.856 Anchor Unparsed SBE41 Message S>pts $ 18-Dec-2018 18:04:05.520 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.831551 32.175000 147.500000 $ 18-Dec-2018 18:04:05.630 Anchor Sci Logger sample Optode $ 18-Dec-2018 18:04:05.647 Anchor Sci Logger sample pH and NO3 $ 18-Dec-2018 18:04:05.749 Anchor Sending FLBB run command $ 18-Dec-2018 18:04:05.850 Anchor Sci Logger sample FLBB $ 18-Dec-2018 18:04:05.955 Anchor Sending radiometer pollSample $ 18-Dec-2018 18:04:06.157 Anchor Sci Logger sample Radiometer $ 18-Dec-2018 18:04:06.301 Anchor Starting ISUS sample $ 18-Dec-2018 18:04:06.404 Anchor Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156192, 25.02, 21.497, 37.91 $ 18-Dec-2018 18:04:06.410 Anchor MSC: OUT: W $ 18-Dec-2018 18:04:06.859 Anchor MSC: OUT: W $ 18-Dec-2018 18:04:06.962 Anchor Radiometer Message SATFI40287,-0.0054,-0.0013,-0.0070,-0.1778 $ 18-Dec-2018 18:04:07.085 Anchor Radiometer post: SATFI40287,-0.0054,-0.0013,-0.0070,-0.1778 $ 18-Dec-2018 18:04:07.090 Anchor MSC: RX: $ 18-Dec-2018 18:04:06.721 Anchor Optode Message 4330,1532,271.222,21.532,29.279,29.211,36.289,7.078,529.2,466.0,141.7 $ 18-Dec-2018 18:04:07.404 Anchor Optode post: 4330,1532,271.222,21.532,29.279,29.211,36.289,7.078,529.2,466.0,141.7 $ 18-Dec-2018 18:04:06.724 Anchor Optode Message # $ 18-Dec-2018 18:04:07.621 Anchor MSC: RX: $ 18-Dec-2018 18:04:07.625 Anchor FLBB Message /99/99,99:99:99,695,2314,700,4130,537 $ 18-Dec-2018 18:04:07.833 Anchor FLBB post: /99/99,99:99:99,695,2314,700,4130,537 $ 18-Dec-2018 18:04:08.040 Anchor PTH Message 767.863281 22.275000 52.979034 23.217063 $ 18-Dec-2018 18:04:08.242 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.859998 32.175000 147.500000 $ 18-Dec-2018 18:04:08.360 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0588476 $ 18-Dec-2018 18:04:08.464 Anchor MSC: RX: ACK $ 18-Dec-2018 18:04:08.468 Anchor MSC: Got ACK $ 18-Dec-2018 18:04:08.869 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.849343 32.175000 147.500000 $ 18-Dec-2018 18:04:09.570 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.866673 32.175000 147.500000 $ 18-Dec-2018 18:04:10.368 Anchor MSC: OUT: CTD,1545156192,21.4969,37.9081,25.0200 $ 18-Dec-2018 18:04:10.688 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.842518 32.175000 147.500000 $ 18-Dec-2018 18:04:11.367 Anchor MSC: RX: ACK,CTD,1545156192,21.4969,37.9081,25.02 $ 18-Dec-2018 18:04:11.677 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.843934 32.175000 147.500000 $ 18-Dec-2018 18:04:12.380 Anchor CTD post: 25.02 21.505 37.94 $ 18-Dec-2018 18:04:11.957 Anchor SBE41 Message 25.02, 21.5049, 37.9376 25.020000 25.516602 0.009112 0.316666 0.000000 -0.004569 3.000000 $ 18-Dec-2018 18:04:12.801 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.873319 32.175000 147.500000 $ 18-Dec-2018 18:04:13.366 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:04:13.671 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.855319 32.175000 147.500000 $ 18-Dec-2018 18:04:14.568 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.863484 32.175000 147.500000 $ 18-Dec-2018 18:04:15.366 Anchor MSC: OUT: W $ 18-Dec-2018 18:04:15.719 Anchor MSC: OUT: W $ 18-Dec-2018 18:04:15.467 Anchor SBE41 Message 25.03 25.030001 25.360571 -0.000896 -0.003333 0.156666 -0.002329 3.000000 $ 18-Dec-2018 18:04:15.946 Anchor MSC: RX: ACK $ 18-Dec-2018 18:04:15.952 Anchor MSC: Got ACK $ 18-Dec-2018 18:04:16.353 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.030001 121.849611 32.175000 147.500000 $ 18-Dec-2018 18:04:16.467 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1009816 $ 18-Dec-2018 18:04:16.570 Anchor MSC: OUT: MODE,1 $ 18-Dec-2018 18:04:16.674 Anchor MSC: RX: ACK $ 18-Dec-2018 18:04:16.776 Anchor MSC: Got ACK $ 18-Dec-2018 18:04:16.982 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.030001 121.863574 32.175000 147.500000 $ 18-Dec-2018 18:04:17.472 Anchor MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:04:17.777 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.030001 121.862024 32.175000 147.500000 $ 18-Dec-2018 18:04:18.418 Anchor SBE41 Message 25.97 25.969999 25.241567 -0.010925 -0.313333 -0.158333 -0.000563 3.000000 $ 18-Dec-2018 18:04:18.800 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.832922 32.175000 147.500000 $ 18-Dec-2018 18:04:19.473 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:04:19.778 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.848330 32.175000 147.500000 $ 18-Dec-2018 18:04:20.675 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.862203 32.175000 147.500000 $ 18-Dec-2018 18:04:21.473 Anchor MSC: OUT: TS $ 18-Dec-2018 18:04:21.418 Anchor SBE41 Message 25.97 25.969999 25.263824 -0.007834 0.000000 -0.156666 0.000581 3.000000 $ 18-Dec-2018 18:04:21.804 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.837825 32.175000 147.500000 $ 18-Dec-2018 18:04:22.473 Anchor MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:04:22.777 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.861517 32.175000 147.500000 $ 18-Dec-2018 18:04:23.675 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.844411 32.175000 147.500000 $ 18-Dec-2018 18:04:24.419 Anchor SBE41 Message 25.09 25.090000 25.325302 0.006216 0.293333 0.146667 0.001128 3.000000 $ 18-Dec-2018 18:04:24.703 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.090000 121.861786 32.175000 147.500000 $ 18-Dec-2018 18:04:25.675 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.090000 121.862978 32.175000 147.500000 $ 18-Dec-2018 18:04:26.675 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.090000 121.850491 32.175000 147.500000 $ 18-Dec-2018 18:04:27.419 Anchor SBE41 Message 25.01 25.010000 25.356962 0.017919 0.026667 0.160000 0.001254 3.000000 $ 18-Dec-2018 18:04:27.799 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.865004 32.175000 147.500000 $ 18-Dec-2018 18:04:28.480 Anchor MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:04:28.687 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.861637 32.175000 147.500000 $ 18-Dec-2018 18:04:29.683 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.860847 32.175000 147.500000 $ 18-Dec-2018 18:04:30.480 Anchor MSC: OUT: SL $ 18-Dec-2018 18:04:30.418 Anchor SBE41 Message 25.02 25.020000 25.433278 0.016647 -0.003333 0.011667 0.001083 3.000000 $ 18-Dec-2018 18:04:30.812 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.842787 32.175000 147.500000 $ 18-Dec-2018 18:04:31.481 Anchor MSC: RX: 0xE1CA,A,02/06/2012 00:29:57,0,-1.00,-1.0000,-1.0000,294,196,1,76,21.15,55.97,11.572,5.288e-01,10870.00,2266.00,1126.22,12.06,-20.42,-191.29,3.391e-02,17,87,4AEC49694726447F4218401A3ED53E453EE2403642494565499E4EE254D15B9062AE69D8706A761A7A207C487CF67BC27926758471366CD468FE659962FD614B6088608F618F634B65FA69636D83724477A67DAD839F89998F74948B98FE9BC99D5B9D389B6A980993158D6286F2800F798073136D4A683063475F3D5BBE58D75653545952BD51AE50ED50855086,6823.6 $ 18-Dec-2018 18:04:31.591 Anchor MSC: Data: 0xE1CA,A,02/06/2012 00:29:57,0,-1.00,-1.0000,-1.0000,294,196,1,76,21.15,55.97,11.572,5.288e-01,10870.00,2266.00,1126.22,12.06,-20.42,-191.29,3.391e-02,17,87,4AEC49694726447F4218401A3ED53E453EE2403642494565499E4EE254D15B9062AE69D8706A761A7A207C487CF67BC27926758471366CD468FE659962FD614B6088608F618F634B65FA69636D83724477A67DAD839F89998F74948B98FE9BC99D5B9D389B6A980993158D6286F2800F798073136D4A683063475F3D5BBE58D75653545952BD51AE50ED50855086,6823.6 $ 18-Dec-2018 18:04:31.703 Anchor MSC post: -191.29 $ 18-Dec-2018 18:04:32.007 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.872574 32.175000 147.500000 $ 18-Dec-2018 18:04:32.480 Anchor MSC: Done Sampling. $ 18-Dec-2018 18:04:32.484 Anchor Starting pH sample $ 18-Dec-2018 18:04:32.586 Anchor MSC: OUT: W $ 18-Dec-2018 18:04:33.035 Anchor MSC: OUT: W $ 18-Dec-2018 18:04:33.138 Anchor MSC: RX: ACK $ 18-Dec-2018 18:04:33.142 Anchor MSC: Got ACK $ 18-Dec-2018 18:04:33.543 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.834934 32.175000 147.500000 $ 18-Dec-2018 18:04:33.656 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1761832 $ 18-Dec-2018 18:04:33.759 Anchor MSC: OUT: MODE,2 $ 18-Dec-2018 18:04:33.864 Anchor MSC: RX: ACK $ 18-Dec-2018 18:04:33.868 Anchor MSC: Got ACK $ 18-Dec-2018 18:04:33.428 Anchor SBE41 Message 25.94 25.940001 25.543620 0.001813 -0.306667 -0.155000 0.000722 3.000000 $ 18-Dec-2018 18:04:34.397 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.857420 32.175000 147.500000 $ 18-Dec-2018 18:04:34.662 Anchor MSC: RX: ACK,MODE,2 $ 18-Dec-2018 18:04:34.967 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.853888 32.175000 147.500000 $ 18-Dec-2018 18:04:35.865 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.862590 32.175000 147.500000 $ 18-Dec-2018 18:04:36.662 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:04:36.449 Anchor SBE41 Message 25.96 25.959999 25.531415 -0.016587 -0.006666 -0.156666 0.000390 3.000000 $ 18-Dec-2018 18:04:37.092 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.839464 32.175000 147.500000 $ 18-Dec-2018 18:04:37.865 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.854156 32.175000 147.500000 $ 18-Dec-2018 18:04:38.663 Anchor MSC: OUT: TS $ 18-Dec-2018 18:04:38.979 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.865317 32.175000 147.500000 $ 18-Dec-2018 18:04:39.663 Anchor MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:04:39.418 Anchor SBE41 Message 25.36 25.360001 25.374171 -0.024517 0.199999 0.096667 0.000299 3.000000 $ 18-Dec-2018 18:04:40.091 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.360001 121.833473 32.175000 147.500000 $ 18-Dec-2018 18:04:40.864 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.360001 121.858507 32.175000 147.500000 $ 18-Dec-2018 18:04:41.864 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.360001 121.854857 32.175000 147.500000 $ 18-Dec-2018 18:04:42.448 Anchor SBE41 Message 24.99 24.990000 25.269995 -0.016367 0.123334 0.161667 0.000438 3.000000 $ 18-Dec-2018 18:04:42.987 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.859998 32.175000 147.500000 $ 18-Dec-2018 18:04:43.864 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.862352 32.175000 147.500000 $ 18-Dec-2018 18:04:44.910 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.855408 32.175000 147.500000 $ 18-Dec-2018 18:04:45.496 Anchor SBE41 Message 24.97 24.969999 25.361704 0.000297 0.006667 0.065000 0.000609 3.000000 $ 18-Dec-2018 18:04:45.987 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.969999 121.875942 32.175000 147.500000 $ 18-Dec-2018 18:04:46.865 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.969999 121.871099 32.175000 147.500000 $ 18-Dec-2018 18:04:47.864 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.969999 121.870533 32.175000 147.500000 $ 18-Dec-2018 18:04:48.661 Anchor MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:04:48.448 Anchor SBE41 Message 25.96 25.959999 25.537207 0.012566 -0.330000 -0.161667 0.000679 3.000000 $ 18-Dec-2018 18:04:48.994 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.847287 32.175000 147.500000 $ 18-Dec-2018 18:04:49.864 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.854782 32.175000 147.500000 $ 18-Dec-2018 18:04:50.661 Anchor MSC: OUT: SL $ 18-Dec-2018 18:04:50.966 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.959999 121.877611 32.175000 147.500000 $ 18-Dec-2018 18:04:51.661 Anchor MSC: RX: 0x827C,pH,02/06/2012 00:30:18,0,-1.00,-1.0000,-1.0000,313,196,0,21.16,55.92,11.744,4.640e-02,7.1234,0.000,-1.029924,0.000916,-1.022538,0.001014,+5.379e-09,+1.324e-09 $ 18-Dec-2018 18:04:51.668 Anchor MSC: Data: 0x827C,pH,02/06/2012 00:30:18,0,-1.00,-1.0000,-1.0000,313,196,0,21.16,55.92,11.744,4.640e-02,7.1234,0.000,-1.029924,0.000916,-1.022538,0.001014,+5.379e-09,+1.324e-09 $ 18-Dec-2018 18:04:51.873 Anchor MSC post: 7.1234 $ 18-Dec-2018 18:04:51.419 Anchor SBE41 Message 25.94 25.940001 25.576417 0.011645 0.006666 -0.161667 0.000689 3.000000 $ 18-Dec-2018 18:04:52.206 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.866703 32.175000 147.500000 $ 18-Dec-2018 18:04:52.661 Anchor MSC: Done Sampling. $ 18-Dec-2018 18:04:52.765 Anchor MSC: OUT: SLP $ 18-Dec-2018 18:04:53.070 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.834576 32.175000 147.500000 $ 18-Dec-2018 18:04:53.661 Anchor MSC: RX: ACK,SLP $ 18-Dec-2018 18:04:53.868 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.845052 32.175000 147.500000 $ 18-Dec-2018 18:04:54.453 Anchor SBE41 Message 25.68 25.680000 25.438108 -0.001166 0.086667 0.046666 0.000695 3.000000 $ 18-Dec-2018 18:04:54.987 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.862024 32.175000 147.500000 $ 18-Dec-2018 18:04:55.865 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.886685 32.175000 147.500000 $ 18-Dec-2018 18:04:56.863 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.680000 121.855870 32.175000 147.500000 $ 18-Dec-2018 18:04:57.447 Anchor SBE41 Message 24.99 24.990000 25.314355 -0.013082 0.230000 0.158333 0.000626 3.000000 $ 18-Dec-2018 18:04:57.890 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.854037 32.175000 147.500000 $ 18-Dec-2018 18:04:58.865 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.844202 32.175000 147.500000 $ 18-Dec-2018 18:04:59.864 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.875852 32.175000 147.500000 $ 18-Dec-2018 18:05:00.449 Anchor SBE41 Message 24.99 24.990000 25.380038 -0.010940 0.000000 0.115000 0.000391 3.000000 $ 18-Dec-2018 18:05:00.988 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.850789 32.175000 147.500000 $ 18-Dec-2018 18:05:01.865 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.864915 32.175000 147.500000 $ 18-Dec-2018 18:05:02.863 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.860459 32.175000 147.500000 $ 18-Dec-2018 18:05:03.448 Anchor SBE41 Message 25.90 25.900000 25.564359 0.002038 -0.303333 -0.151667 0.000078 3.000000 $ 18-Dec-2018 18:05:03.992 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.870369 32.175000 147.500000 $ 18-Dec-2018 18:05:04.789 Anchor Sending CTD PTS $ 18-Dec-2018 18:05:04.895 Anchor Sci Logger sample CTD pts $ 18-Dec-2018 18:05:04.900 Anchor Sending Optode Do Sample $ 18-Dec-2018 18:05:05.098 Anchor Sending Optode Wakeup $ 18-Dec-2018 18:05:05.202 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.867299 32.175000 147.500000 $ 18-Dec-2018 18:05:05.603 Anchor Sci Logger sample Optode $ 18-Dec-2018 18:05:05.620 Anchor Sci Logger sample pH and NO3 $ 18-Dec-2018 18:05:05.722 Anchor Sending FLBB run command $ 18-Dec-2018 18:05:05.823 Anchor Sci Logger sample FLBB $ 18-Dec-2018 18:05:05.928 Anchor Sending radiometer pollSample $ 18-Dec-2018 18:05:06.030 Anchor Starting ISUS sample $ 18-Dec-2018 18:05:06.229 Anchor Sci Logger sample Radiometer $ 18-Dec-2018 18:05:06.335 Anchor Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156252, 25.02, 21.505, 37.94 $ 18-Dec-2018 18:05:06.343 Anchor MSC: OUT: W $ 18-Dec-2018 18:05:06.794 Anchor MSC: OUT: W $ 18-Dec-2018 18:05:04.895 Anchor Unparsed SBE41 Message S>pts $ 18-Dec-2018 18:05:06.915 Anchor Radiometer Message SATFI40287,-0.0046,0.0005,-0.0072,-0.1699 $ 18-Dec-2018 18:05:07.130 Anchor Radiometer post: SATFI40287,-0.0046,0.0005,-0.0072,-0.1699 $ 18-Dec-2018 18:05:07.233 Anchor MSC: RX: $ 18-Dec-2018 18:05:06.695 Anchor Optode Message 4330,1532,270.971,21.558,29.278,29.210,36.293,7.082,529.0,465.6,140.9 $ 18-Dec-2018 18:05:07.451 Anchor Optode post: 4330,1532,270.971,21.558,29.278,29.210,36.293,7.082,529.0,465.6,140.9 $ 18-Dec-2018 18:05:06.698 Anchor Optode Message # $ 18-Dec-2018 18:05:07.666 Anchor MSC: RX: $ 18-Dec-2018 18:05:07.670 Anchor FLBB Message /99/99,99:99:99,695,2315,700,4130,536 $ 18-Dec-2018 18:05:07.880 Anchor FLBB post: /99/99,99:99:99,695,2315,700,4130,536 $ 18-Dec-2018 18:05:08.087 Anchor PTH Message 767.602295 22.333333 52.925629 23.238513 $ 18-Dec-2018 18:05:08.289 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.853232 32.150000 148.000000 $ 18-Dec-2018 18:05:08.400 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3699837 $ 18-Dec-2018 18:05:08.505 Anchor MSC: RX: ACK $ 18-Dec-2018 18:05:08.607 Anchor MSC: Got ACK $ 18-Dec-2018 18:05:08.813 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.849552 32.150000 148.000000 $ 18-Dec-2018 18:05:09.610 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.832713 32.150000 148.000000 $ 18-Dec-2018 18:05:10.409 Anchor MSC: OUT: CTD,1545156252,21.5049,37.9376,25.0200 $ 18-Dec-2018 18:05:10.729 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.853739 32.150000 148.000000 $ 18-Dec-2018 18:05:11.409 Anchor MSC: RX: ACK,CTD,1545156252,21.5049,37.9376,25.02 $ 18-Dec-2018 18:05:11.717 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.863186 32.150000 148.000000 $ 18-Dec-2018 18:05:12.422 Anchor CTD post: 25.01 21.509 37.93 $ 18-Dec-2018 18:05:11.997 Anchor SBE41 Message 25.01, 21.5090, 37.9330 25.010000 25.642748 0.008586 0.296666 -0.003333 -0.000108 3.000000 $ 18-Dec-2018 18:05:12.746 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.854037 32.150000 148.000000 $ 18-Dec-2018 18:05:13.408 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:05:13.713 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.866047 32.150000 148.000000 $ 18-Dec-2018 18:05:14.611 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.856928 32.150000 148.000000 $ 18-Dec-2018 18:05:15.409 Anchor MSC: OUT: W $ 18-Dec-2018 18:05:15.762 Anchor MSC: OUT: W $ 18-Dec-2018 18:05:14.951 Anchor Unparsed SBE41 Message S> $ 18-Dec-2018 18:05:15.884 Anchor MSC: RX: ACK $ 18-Dec-2018 18:05:15.985 Anchor MSC: Got ACK $ 18-Dec-2018 18:05:16.289 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.862963 32.150000 148.000000 $ 18-Dec-2018 18:05:16.409 Anchor MSC: OUT: MODE,1 $ 18-Dec-2018 18:05:16.516 Anchor MSC: RX: ACK $ 18-Dec-2018 18:05:16.617 Anchor MSC: Got ACK $ 18-Dec-2018 18:05:16.823 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.855840 32.150000 148.000000 $ 18-Dec-2018 18:05:17.410 Anchor MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:05:17.512 Anchor SBE41 Message 25.01 25.010000 25.526307 -0.000408 0.000000 0.148333 -0.000044 3.000000 $ 18-Dec-2018 18:05:17.746 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.849865 32.150000 148.000000 $ 18-Dec-2018 18:05:18.409 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:05:18.715 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.849909 32.150000 148.000000 $ 18-Dec-2018 18:05:19.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.841475 32.150000 148.000000 $ 18-Dec-2018 18:05:20.409 Anchor MSC: OUT: TS $ 18-Dec-2018 18:05:20.511 Anchor SBE41 Message 25.97 25.969999 25.359648 -0.013869 -0.320000 -0.160000 0.000107 3.000000 $ 18-Dec-2018 18:05:20.742 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.870175 32.150000 148.000000 $ 18-Dec-2018 18:05:21.410 Anchor MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:05:21.715 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.870965 32.150000 148.000000 $ 18-Dec-2018 18:05:22.613 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.883363 32.150000 148.000000 $ 18-Dec-2018 18:05:23.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.844769 32.150000 148.000000 $ 18-Dec-2018 18:05:23.418 Anchor SBE41 Message 25.97 25.969999 25.295572 -0.014536 0.000000 -0.160000 0.000149 3.000000 $ 18-Dec-2018 18:05:24.735 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.863931 32.150000 148.000000 $ 18-Dec-2018 18:05:25.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.874467 32.150000 148.000000 $ 18-Dec-2018 18:05:26.613 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.969999 121.873602 32.150000 148.000000 $ 18-Dec-2018 18:05:26.419 Anchor SBE41 Message 25.46 25.459999 25.306059 0.000897 0.170000 0.085000 0.000161 3.000000 $ 18-Dec-2018 18:05:27.535 Anchor MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:05:27.839 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.459999 121.860892 32.150000 148.000000 $ 18-Dec-2018 18:05:28.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.459999 121.843174 32.150000 148.000000 $ 18-Dec-2018 18:05:29.410 Anchor MSC: OUT: SL $ 18-Dec-2018 18:05:29.512 Anchor SBE41 Message 25.00 25.000000 25.332062 0.020167 0.153333 0.161667 0.000306 3.000000 $ 18-Dec-2018 18:05:29.840 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.876672 32.150000 148.000000 $ 18-Dec-2018 18:05:30.411 Anchor MSC: RX: 0xE11A,A,02/06/2012 00:30:56,0,-1.00,-1.0000,-1.0000,295,196,1,76,21.23,55.75,11.572,5.302e-01,10857.00,2262.00,1126.94,11.87,-20.40,-191.36,3.397e-02,17,87,4AC3494F4707446B41CB3FF63E9F3E3E3EBF401A42214547497E4EA954A45B7E626B699C703275D879E87C037CB47B9078F1755470F76CA068C8656962C5612860496043615E633065CD69356D59723577657D69836E894F8F38946898B39B799D1E9D009B2097BF92EA8D24867F7FFA795972F16D1E67FF63285F0F5B8C58B65623544252AE51A350D5506B5074,6809.0 $ 18-Dec-2018 18:05:30.423 Anchor MSC: Data: 0xE11A,A,02/06/2012 00:30:56,0,-1.00,-1.0000,-1.0000,295,196,1,76,21.23,55.75,11.572,5.302e-01,10857.00,2262.00,1126.94,11.87,-20.40,-191.36,3.397e-02,17,87,4AC3494F4707446B41CB3FF63E9F3E3E3EBF401A42214547497E4EA954A45B7E626B699C703275D879E87C037CB47B9078F1755470F76CA068C8656962C5612860496043615E633065CD69356D59723577657D69836E894F8F38946898B39B799D1E9D009B2097BF92EA8D24867F7FFA795972F16D1E67FF63285F0F5B8C58B65623544252AE51A350D5506B5074,6809.0 $ 18-Dec-2018 18:05:30.632 Anchor MSC post: -191.36 $ 18-Dec-2018 18:05:30.936 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.860772 32.150000 148.000000 $ 18-Dec-2018 18:05:31.410 Anchor MSC: Done Sampling. $ 18-Dec-2018 18:05:31.414 Anchor Starting pH sample $ 18-Dec-2018 18:05:31.516 Anchor MSC: OUT: W $ 18-Dec-2018 18:05:31.966 Anchor MSC: OUT: W $ 18-Dec-2018 18:05:32.068 Anchor MSC: RX: ACK $ 18-Dec-2018 18:05:32.170 Anchor MSC: Got ACK $ 18-Dec-2018 18:05:32.376 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.855810 32.150000 148.000000 $ 18-Dec-2018 18:05:32.490 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0798119 $ 18-Dec-2018 18:05:32.593 Anchor MSC: OUT: MODE,2 $ 18-Dec-2018 18:05:32.697 Anchor MSC: RX: ACK $ 18-Dec-2018 18:05:32.702 Anchor MSC: Got ACK $ 18-Dec-2018 18:05:32.488 Anchor SBE41 Message 24.99 24.990000 25.426124 0.028071 0.003333 0.078333 0.000448 3.000000 $ 18-Dec-2018 18:05:33.130 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.837512 32.150000 148.000000 $ 18-Dec-2018 18:05:33.496 Anchor MSC: RX: ACK,MODE,2 $ 18-Dec-2018 18:05:33.800 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.854901 32.150000 148.000000 $ 18-Dec-2018 18:05:34.698 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.863648 32.150000 148.000000 $ 18-Dec-2018 18:05:35.495 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:05:35.419 Anchor SBE41 Message 25.92 25.920000 25.573815 0.017330 -0.310000 -0.153333 0.000347 3.000000 $ 18-Dec-2018 18:05:35.925 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.865824 32.150000 148.000000 $ 18-Dec-2018 18:05:36.699 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.855617 32.150000 148.000000 $ 18-Dec-2018 18:05:37.497 Anchor MSC: OUT: TS $ 18-Dec-2018 18:05:37.806 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.869266 32.150000 148.000000 $ 18-Dec-2018 18:05:38.497 Anchor MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:05:38.418 Anchor SBE41 Message 25.94 25.940001 25.610810 -0.005652 -0.006667 -0.158333 0.000040 3.000000 $ 18-Dec-2018 18:05:38.828 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.864393 32.150000 148.000000 $ 18-Dec-2018 18:05:39.699 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.860057 32.150000 148.000000 $ 18-Dec-2018 18:05:40.700 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.846840 32.150000 148.000000 $ 18-Dec-2018 18:05:41.419 Anchor SBE41 Message 25.92 25.920000 25.475695 -0.023963 0.006667 0.000000 -0.000212 3.000000 $ 18-Dec-2018 18:05:41.730 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.878982 32.150000 148.000000 $ 18-Dec-2018 18:05:42.719 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.877983 32.150000 148.000000 $ 18-Dec-2018 18:05:43.719 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.857047 32.150000 148.000000 $ 18-Dec-2018 18:05:44.419 Anchor SBE41 Message 24.99 24.990000 25.342531 -0.024726 0.310000 0.158333 -0.000346 3.000000 $ 18-Dec-2018 18:05:44.842 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.861503 32.150000 148.000000 $ 18-Dec-2018 18:05:45.718 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.863201 32.150000 148.000000 $ 18-Dec-2018 18:05:46.718 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.846542 32.150000 148.000000 $ 18-Dec-2018 18:05:47.515 Anchor MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:05:47.419 Anchor SBE41 Message 24.99 24.990000 25.395368 -0.010197 0.000000 0.155000 -0.000542 3.000000 $ 18-Dec-2018 18:05:47.945 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.856734 32.150000 148.000000 $ 18-Dec-2018 18:05:48.717 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.875256 32.150000 148.000000 $ 18-Dec-2018 18:05:49.515 Anchor MSC: OUT: SL $ 18-Dec-2018 18:05:49.819 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.868774 32.150000 148.000000 $ 18-Dec-2018 18:05:50.516 Anchor MSC: RX: 0x48AC,pH,02/06/2012 00:31:17,0,-1.00,-1.0000,-1.0000,314,196,0,21.26,55.70,11.744,4.640e-02,7.1234,0.000,-1.028581,0.000914,-1.021194,0.000996,+6.808e-09,+1.843e-09 $ 18-Dec-2018 18:05:50.621 Anchor MSC: Data: 0x48AC,pH,02/06/2012 00:31:17,0,-1.00,-1.0000,-1.0000,314,196,0,21.26,55.70,11.744,4.640e-02,7.1234,0.000,-1.028581,0.000914,-1.021194,0.000996,+6.808e-09,+1.843e-09 $ 18-Dec-2018 18:05:50.728 Anchor MSC post: 7.1234 $ 18-Dec-2018 18:05:50.418 Anchor SBE41 Message 25.77 25.770000 25.585169 0.006284 -0.260000 -0.130000 -0.000848 3.000000 $ 18-Dec-2018 18:05:51.058 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 121.894121 32.150000 148.000000 $ 18-Dec-2018 18:05:51.516 Anchor MSC: Done Sampling. $ 18-Dec-2018 18:05:51.520 Anchor MSC: OUT: SLP $ 18-Dec-2018 18:05:51.923 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 121.868655 32.150000 148.000000 $ 18-Dec-2018 18:05:52.516 Anchor MSC: RX: ACK,SLP $ 18-Dec-2018 18:05:52.723 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.770000 121.860668 32.150000 148.000000 $ 18-Dec-2018 18:05:53.418 Anchor SBE41 Message 25.94 25.940001 25.690170 0.011109 -0.056667 -0.158333 -0.001063 3.000000 $ 18-Dec-2018 18:05:53.843 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.858969 32.150000 148.000000 $ 18-Dec-2018 18:05:54.719 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.858701 32.150000 148.000000 $ 18-Dec-2018 18:05:55.719 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.866867 32.150000 148.000000 $ 18-Dec-2018 18:05:56.418 Anchor SBE41 Message 25.94 25.940001 25.591547 0.000222 0.000000 -0.028333 -0.001048 3.000000 $ 18-Dec-2018 18:05:56.843 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.850058 32.150000 148.000000 $ 18-Dec-2018 18:05:57.720 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.853307 32.150000 148.000000 $ 18-Dec-2018 18:05:58.719 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.940001 121.870682 32.150000 148.000000 $ 18-Dec-2018 18:05:59.418 Anchor SBE41 Message 25.02 25.020000 25.423982 -0.014961 0.306667 0.153333 -0.000949 3.000000 $ 18-Dec-2018 18:05:59.844 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.875063 32.150000 148.000000 $ 18-Dec-2018 18:06:00.720 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.864587 32.150000 148.000000 $ 18-Dec-2018 18:06:01.720 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.020000 121.857017 32.150000 148.000000 $ 18-Dec-2018 18:06:02.419 Anchor SBE41 Message 25.00 25.000000 25.405905 -0.016881 0.006667 0.156667 -0.001004 3.000000 $ 18-Dec-2018 18:06:02.844 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.861354 32.150000 148.000000 $ 18-Dec-2018 18:06:03.721 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.869534 32.150000 148.000000 $ 18-Dec-2018 18:06:03.839 Anchor Unparsed SBE41 Message S> $ 18-Dec-2018 18:06:04.739 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.852368 32.150000 148.000000 $ 18-Dec-2018 18:06:04.854 Anchor Sending CTD PTS $ 18-Dec-2018 18:06:04.858 Anchor Sci Logger sample CTD pts $ 18-Dec-2018 18:06:05.062 Anchor Sending Optode Do Sample $ 18-Dec-2018 18:06:05.066 Anchor Sending Optode Wakeup $ 18-Dec-2018 18:06:04.961 Anchor Unparsed SBE41 Message S>pts $ 18-Dec-2018 18:06:05.668 Anchor Sci Logger sample Optode $ 18-Dec-2018 18:06:05.688 Anchor Sci Logger sample pH and NO3 $ 18-Dec-2018 18:06:05.789 Anchor Sending FLBB run command $ 18-Dec-2018 18:06:05.891 Anchor Sci Logger sample FLBB $ 18-Dec-2018 18:06:05.996 Anchor Sending radiometer pollSample $ 18-Dec-2018 18:06:06.196 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.865153 32.150000 148.000000 $ 18-Dec-2018 18:06:06.308 Anchor Sci Logger sample Radiometer $ 18-Dec-2018 18:06:06.519 Anchor Starting ISUS sample $ 18-Dec-2018 18:06:06.622 Anchor Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156312, 25.01, 21.509, 37.93 $ 18-Dec-2018 18:06:06.627 Anchor MSC: OUT: W $ 18-Dec-2018 18:06:07.079 Anchor MSC: OUT: W $ 18-Dec-2018 18:06:07.184 Anchor Radiometer Message SATFI40287,-0.0049,-0.0012,-0.0082,-0.1646 $ 18-Dec-2018 18:06:07.298 Anchor Radiometer post: SATFI40287,-0.0049,-0.0012,-0.0082,-0.1646 $ 18-Dec-2018 18:06:06.828 Anchor Optode Message 4330,1532,270.873,21.588,29.270,29.202,36.287,7.085,528.8,465.4,139.9 $ 18-Dec-2018 18:06:07.517 Anchor Optode post: 4330,1532,270.873,21.588,29.270,29.202,36.287,7.085,528.8,465.4,139.9 $ 18-Dec-2018 18:06:06.828 Anchor Optode Message # $ 18-Dec-2018 18:06:07.635 Anchor MSC: RX: $ 18-Dec-2018 18:06:07.737 Anchor MSC: RX: $ 18-Dec-2018 18:06:07.936 Anchor FLBB Message /99/99,99:99:99,695,2315,700,4130,536 $ 18-Dec-2018 18:06:08.048 Anchor FLBB post: /99/99,99:99:99,695,2315,700,4130,536 $ 18-Dec-2018 18:06:08.353 Anchor PTH Message 767.929688 22.166667 52.902740 23.259963 $ 18-Dec-2018 18:06:08.555 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.849701 32.150000 147.000000 $ 18-Dec-2018 18:06:08.668 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1495763 $ 18-Dec-2018 18:06:08.772 Anchor MSC: RX: ACK $ 18-Dec-2018 18:06:08.776 Anchor MSC: Got ACK $ 18-Dec-2018 18:06:09.079 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.855587 32.150000 147.000000 $ 18-Dec-2018 18:06:09.876 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.872351 32.150000 147.000000 $ 18-Dec-2018 18:06:10.675 Anchor MSC: OUT: CTD,1545156312,21.5090,37.9330,25.0100 $ 18-Dec-2018 18:06:10.994 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.854514 32.150000 147.000000 $ 18-Dec-2018 18:06:11.673 Anchor MSC: RX: ACK,CTD,1545156312,21.5090,37.9330,25.01 $ 18-Dec-2018 18:06:11.981 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.887639 32.150000 147.000000 $ 18-Dec-2018 18:06:12.686 Anchor CTD post: 25.92 21.513 37.93 $ 18-Dec-2018 18:06:12.093 Anchor SBE41 Message 25.92, 21.5126, 37.9330 25.920000 25.554187 -0.002838 -0.306667 -0.150000 -0.001212 3.000000 $ 18-Dec-2018 18:06:13.010 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.860310 32.150000 147.000000 $ 18-Dec-2018 18:06:13.673 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:06:13.979 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.861830 32.150000 147.000000 $ 18-Dec-2018 18:06:14.875 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.861607 32.150000 147.000000 $ 18-Dec-2018 18:06:15.673 Anchor MSC: OUT: W $ 18-Dec-2018 18:06:16.025 Anchor MSC: OUT: W $ 18-Dec-2018 18:06:15.461 Anchor SBE41 Message 24.98 24.980000 25.665140 0.010675 0.313334 0.003333 -0.001354 3.000000 $ 18-Dec-2018 18:06:16.252 Anchor MSC: RX: ACK $ 18-Dec-2018 18:06:16.256 Anchor MSC: Got ACK $ 18-Dec-2018 18:06:16.658 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.867701 32.150000 147.000000 $ 18-Dec-2018 18:06:16.771 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0987748 $ 18-Dec-2018 18:06:16.875 Anchor MSC: OUT: MODE,1 $ 18-Dec-2018 18:06:16.979 Anchor MSC: RX: ACK $ 18-Dec-2018 18:06:16.983 Anchor MSC: Got ACK $ 18-Dec-2018 18:06:17.384 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.863529 32.150000 147.000000 $ 18-Dec-2018 18:06:17.777 Anchor MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:06:18.081 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.862620 32.150000 147.000000 $ 18-Dec-2018 18:06:27.926 Anchor Checking for sequencePHandN03 done $ 18-Dec-2018 18:06:18.418 Anchor SBE41 Message 24.99 24.990000 25.591405 0.008747 -0.003333 0.155000 -0.001283 3.000000 $ 18-Dec-2018 18:06:28.261 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.855825 32.150000 147.000000 $ 18-Dec-2018 18:06:28.372 Anchor ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:09.5956820 $ 18-Dec-2018 18:06:28.475 Anchor MSC: OUT: ACK $ 18-Dec-2018 18:06:28.780 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.870890 32.150000 147.000000 $ 18-Dec-2018 18:06:29.379 Anchor MSC: RX: NAK,UnrecognizedCmdStr: ACK $ 18-Dec-2018 18:06:29.683 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.990000 121.882811 32.150000 147.000000 $ 18-Dec-2018 18:06:30.378 Anchor MSC: OUT: TS $ 18-Dec-2018 18:06:29.954 Anchor SBE41 Message 25.37 25.370001 25.426161 -0.003868 -0.126667 -0.065000 -0.001104 3.000000 $ 18-Dec-2018 18:06:30.811 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.370001 121.863380 32.150000 147.000000 $ 18-Dec-2018 18:06:31.379 Anchor MSC: RX: NAK,TS,InvalidModeValue: 0 $ 18-Dec-2018 18:06:31.684 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.370001 121.871576 32.150000 147.000000 $ 18-Dec-2018 18:06:32.581 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.370001 121.866867 32.150000 147.000000 $ 18-Dec-2018 18:06:32.917 Anchor SBE41 Message 24.98 24.980000 25.331113 -0.010233 0.130000 0.001667 -0.001008 3.000000 $ 18-Dec-2018 18:06:33.608 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.864736 32.150000 147.000000 $ 18-Dec-2018 18:06:34.582 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.888816 32.150000 147.000000 $ 18-Dec-2018 18:06:35.583 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.850237 32.150000 147.000000 $ 18-Dec-2018 18:06:35.919 Anchor SBE41 Message 24.98 24.980000 25.298125 -0.001407 0.000000 0.065000 -0.000882 3.000000 $ 18-Dec-2018 18:06:36.708 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.851206 32.150000 147.000000 $ 18-Dec-2018 18:06:37.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.875465 32.150000 147.000000 $ 18-Dec-2018 18:06:38.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.874735 32.150000 147.000000 $ 18-Dec-2018 18:06:38.919 Anchor SBE41 Message 25.93 25.930000 25.239554 0.016350 -0.316667 -0.158333 -0.000554 3.000000 $ 18-Dec-2018 18:06:39.610 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.930000 121.871501 32.150000 147.000000 $ 18-Dec-2018 18:06:40.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.930000 121.866018 32.150000 147.000000 $ 18-Dec-2018 18:06:41.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.930000 121.844202 32.150000 147.000000 $ 18-Dec-2018 18:06:41.917 Anchor SBE41 Message 25.90 25.900000 25.169630 0.029903 0.010000 -0.153333 -0.000053 3.000000 $ 18-Dec-2018 18:06:42.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.871710 32.150000 147.000000 $ 18-Dec-2018 18:06:43.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.863693 32.150000 147.000000 $ 18-Dec-2018 18:06:44.583 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.850982 32.150000 147.000000 $ 18-Dec-2018 18:06:44.917 Anchor SBE41 Message 25.90 25.900000 25.143344 0.031258 0.000000 0.005000 0.000431 3.000000 $ 18-Dec-2018 18:06:45.610 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.862754 32.150000 147.000000 $ 18-Dec-2018 18:06:46.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.850789 32.150000 147.000000 $ 18-Dec-2018 18:06:47.583 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 121.861771 32.150000 147.000000 $ 18-Dec-2018 18:06:47.919 Anchor SBE41 Message 25.00 25.000000 25.192196 0.024191 0.300000 0.150000 0.000783 3.000000 $ 18-Dec-2018 18:06:48.709 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.877432 32.150000 147.000000 $ 18-Dec-2018 18:06:49.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.856898 32.150000 147.000000 $ 18-Dec-2018 18:06:50.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.854663 32.150000 147.000000 $ 18-Dec-2018 18:06:50.919 Anchor SBE41 Message 25.00 25.000000 25.350836 0.016708 0.000000 0.150000 0.000929 3.000000 $ 18-Dec-2018 18:06:51.610 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.866673 32.150000 147.000000 $ 18-Dec-2018 18:06:52.584 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.862680 32.150000 147.000000 $ 18-Dec-2018 18:06:53.585 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 121.872529 32.150000 147.000000 $ 18-Dec-2018 18:06:53.919 Anchor SBE41 Message 25.17 25.170000 25.568712 0.007197 -0.056667 -0.028333 0.000783 3.000000 $ 18-Dec-2018 18:06:54.710 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 121.859804 32.150000 147.000000 $ 18-Dec-2018 18:06:55.585 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 121.864572 32.150000 147.000000 $ 18-Dec-2018 18:06:56.586 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.170000 121.874839 32.150000 147.000000 $ 18-Dec-2018 18:06:56.919 Anchor SBE41 Message 25.95 25.950001 25.674539 -0.011501 -0.260000 -0.158333 0.000438 3.000000 $ 18-Dec-2018 18:06:57.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.877909 32.150000 147.000000 $ 18-Dec-2018 18:06:58.586 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.852279 32.150000 147.000000 $ 18-Dec-2018 18:06:59.586 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.950001 121.869102 32.150000 147.000000 $ 18-Dec-2018 18:06:59.918 Anchor SBE41 Message 25.93 25.930000 25.566309 -0.034233 0.006667 -0.126667 0.000221 3.000000 $ 18-Dec-2018 18:07:00.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.930000 121.851444 32.150000 147.000000 $ 18-Dec-2018 18:07:01.586 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.930000 121.856049 32.150000 147.000000 $ 18-Dec-2018 18:07:02.585 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.930000 121.868104 32.150000 147.000000 $ 18-Dec-2018 18:07:02.918 Anchor SBE41 Message 25.01 25.010000 25.359719 -0.043533 0.306667 0.156667 0.000361 3.000000 $ 18-Dec-2018 18:07:03.612 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.868819 32.150000 147.000000 $ 18-Dec-2018 18:07:04.586 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.860147 32.150000 147.000000 $ 18-Dec-2018 18:07:04.749 Anchor Sending CTD PTS $ 18-Dec-2018 18:07:04.753 Anchor Sci Logger sample CTD pts $ 18-Dec-2018 18:07:04.957 Anchor Sending Optode Do Sample $ 18-Dec-2018 18:07:04.961 Anchor Sending Optode Wakeup $ 18-Dec-2018 18:07:04.856 Anchor Unparsed SBE41 Message S>pts $ 18-Dec-2018 18:07:05.575 Anchor Sci Logger sample Optode $ 18-Dec-2018 18:07:05.581 Anchor Sci Logger sample pH and NO3 $ 18-Dec-2018 18:07:05.683 Anchor Sending FLBB run command $ 18-Dec-2018 18:07:05.784 Anchor Sci Logger sample FLBB $ 18-Dec-2018 18:07:05.987 Anchor Sending radiometer pollSample $ 18-Dec-2018 18:07:06.089 Anchor Sci Logger sample Radiometer $ 18-Dec-2018 18:07:06.192 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.876240 32.150000 147.000000 $ 18-Dec-2018 18:07:06.383 Anchor Radiometer Message SATFI40287,-0.0046,-0.0001,-0.0073,-0.1904 $ 18-Dec-2018 18:07:06.498 Anchor Radiometer post: SATFI40287,-0.0046,-0.0001,-0.0073,-0.1904 $ 18-Dec-2018 18:07:06.705 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.855125 32.150000 147.000000 $ 18-Dec-2018 18:07:06.652 Anchor Optode Message 4330,1532,270.684,21.617,29.266,29.198,36.284,7.086,528.6,465.1,139.0 $ 18-Dec-2018 18:07:07.500 Anchor Optode post: 4330,1532,270.684,21.617,29.266,29.198,36.284,7.086,528.6,465.1,139.0 $ 18-Dec-2018 18:07:06.655 Anchor Optode Message # $ 18-Dec-2018 18:07:07.617 Anchor FLBB Message /99/99,99:99:99,695,2314,700,4130,535 $ 18-Dec-2018 18:07:07.824 Anchor FLBB post: /99/99,99:99:99,695,2314,700,4130,535 $ 18-Dec-2018 18:07:08.036 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.873751 32.150000 147.000000 $ 18-Dec-2018 18:07:08.586 Anchor PTH Message 767.963379 22.300000 52.933258 23.270688 $ 18-Dec-2018 18:07:08.788 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.856973 32.150000 137.500000 $ 18-Dec-2018 18:07:09.587 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.864334 32.150000 137.500000 $ 18-Dec-2018 18:07:10.587 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.862173 32.150000 137.500000 $ 18-Dec-2018 18:07:11.587 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.010000 121.871024 32.150000 137.500000 $ 18-Dec-2018 18:07:12.398 Anchor CTD post: 25.92 21.514 37.94 $ 18-Dec-2018 18:07:11.958 Anchor SBE41 Message 25.92, 21.5141, 37.9426 25.920000 25.273282 -0.029361 -0.303333 0.001667 0.000692 3.000000 $ 18-Dec-2018 18:07:12.722 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.871203 32.150000 137.500000 $ 18-Dec-2018 18:07:13.384 Anchor Checking for sequencePHandNO3 done timed out $ 18-Dec-2018 18:07:13.688 Anchor Normal State Exit $ 18-Dec-2018 18:07:13.798 Anchor Anchor pt: 2018-Dec-18T18:07:13Z NaN NaN NaN NaN NaN NaN NaN NaN NaN NaN NaN NaN NaN NaN NaN $ 18-Dec-2018 18:07:13.906 Anchor ERROR: Missed CTD message 1 $ 18-Dec-2018 18:07:13.911 Anchor ERROR: Missed PH message 1 $ 18-Dec-2018 18:07:14.013 Anchor ERROR: Missed NO3 message 1 $ 18-Dec-2018 18:07:14.116 Anchor RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.859252 32.150000 137.500000 $ 18-Dec-2018 18:07:14.384 Start CP Mode State Entry $ 18-Dec-2018 18:07:14.389 Start CP Mode Stopping SBE41 Timer $ 18-Dec-2018 18:07:13.902 Start CP Mode Unparsed SBE41 Message S> $ 18-Dec-2018 18:07:14.793 Start CP Mode Sending CTD PTS $ 18-Dec-2018 18:07:14.797 Start CP Mode Sci Logger sample CTD pts $ 18-Dec-2018 18:07:14.905 Start CP Mode Sending Optode Do Sample $ 18-Dec-2018 18:07:15.007 Start CP Mode Sending Optode Wakeup $ 18-Dec-2018 18:07:15.209 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.868193 32.150000 137.500000 $ 18-Dec-2018 18:07:14.900 Start CP Mode Unparsed SBE41 Message S>pts $ 18-Dec-2018 18:07:15.607 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.868849 32.150000 137.500000 $ 18-Dec-2018 18:07:15.719 Start CP Mode Sci Logger sample Optode $ 18-Dec-2018 18:07:15.736 Start CP Mode Sci Logger sample pH and NO3 $ 18-Dec-2018 18:07:15.838 Start CP Mode Sending FLBB run command $ 18-Dec-2018 18:07:15.939 Start CP Mode Sci Logger sample FLBB $ 18-Dec-2018 18:07:16.044 Start CP Mode Sending radiometer pollSample $ 18-Dec-2018 18:07:16.246 Start CP Mode Sci Logger sample Radiometer $ 18-Dec-2018 18:07:16.389 Start CP Mode Radiometer Message SATFI40287,-0.0036,-0.0011,-0.0080,-0.1971 $ 18-Dec-2018 18:07:16.503 Start CP Mode Radiometer post: SATFI40287,-0.0036,-0.0011,-0.0080,-0.1971 $ 18-Dec-2018 18:07:16.710 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.867880 32.150000 137.500000 $ 18-Dec-2018 18:07:17.389 Start CP Mode SBE41 Timer Stopped, Sending SBE41 CR/LF $ 18-Dec-2018 18:07:16.824 Start CP Mode Optode Message 4330,1532,270.790,21.620,29.261,29.192,36.280,7.088,528.5,464.7,138.9 $ 18-Dec-2018 18:07:17.606 Start CP Mode Optode post: 4330,1532,270.790,21.620,29.261,29.192,36.280,7.088,528.5,464.7,138.9 $ 18-Dec-2018 18:07:16.824 Start CP Mode Optode Message # $ 18-Dec-2018 18:07:17.822 Start CP Mode FLBB Message /99/99,99:99:99,695,2313,700,4130,535 $ 18-Dec-2018 18:07:17.933 Start CP Mode FLBB post: /99/99,99:99:99,695,2313,700,4130,535 $ 18-Dec-2018 18:07:18.139 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.870741 32.150000 137.500000 $ 18-Dec-2018 18:07:18.390 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:18.600 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.894434 32.150000 137.500000 $ 18-Dec-2018 18:07:19.390 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:19.597 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.882722 32.150000 137.500000 $ 18-Dec-2018 18:07:20.390 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:20.597 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.873736 32.150000 137.500000 $ 18-Dec-2018 18:07:21.391 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:21.598 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 25.920000 121.876866 32.150000 137.500000 $ 18-Dec-2018 18:07:22.392 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:22.507 Start CP Mode CTD post: 24.98 21.517 30.70 $ 18-Dec-2018 18:07:22.007 Start CP Mode SBE41 Message 24.98, 21.5165, 30.6953 24.980000 25.384922 -0.000675 0.313334 0.005000 0.000809 3.000000 $ 18-Dec-2018 18:07:22.831 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.871978 32.150000 137.500000 $ 18-Dec-2018 18:07:23.391 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:23.598 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.862322 32.150000 137.500000 $ 18-Dec-2018 18:07:24.392 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:24.599 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.868581 32.150000 137.500000 $ 18-Dec-2018 18:07:25.392 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:25.599 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.865869 32.150000 137.500000 $ 18-Dec-2018 18:07:26.393 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:26.701 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.877581 32.150000 137.500000 $ 18-Dec-2018 18:07:27.392 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:27.600 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.870399 32.150000 137.500000 $ 18-Dec-2018 18:07:28.393 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:28.599 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.883854 32.150000 137.500000 $ 18-Dec-2018 18:07:29.394 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:29.601 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.871218 32.150000 137.500000 $ 18-Dec-2018 18:07:30.394 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:30.601 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.866629 32.150000 137.500000 $ 18-Dec-2018 18:07:31.394 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:31.692 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.864125 32.150000 137.500000 $ 18-Dec-2018 18:07:32.394 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:32.600 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.880963 32.150000 137.500000 $ 18-Dec-2018 18:07:33.395 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:33.603 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.868461 32.150000 137.500000 $ 18-Dec-2018 18:07:34.395 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:34.699 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.869266 32.150000 137.500000 $ 18-Dec-2018 18:07:35.395 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:35.601 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.874124 32.150000 137.500000 $ 18-Dec-2018 18:07:36.396 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:36.603 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.878415 32.150000 137.500000 $ 18-Dec-2018 18:07:37.395 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:37.602 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.865109 32.150000 137.500000 $ 18-Dec-2018 18:07:38.412 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:38.716 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.881887 32.150000 137.500000 $ 18-Dec-2018 18:07:39.413 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:39.620 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.870384 32.150000 137.500000 $ 18-Dec-2018 18:07:40.413 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:40.621 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.874407 32.150000 137.500000 $ 18-Dec-2018 18:07:41.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:41.621 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.875063 32.150000 137.500000 $ 18-Dec-2018 18:07:42.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:42.718 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.873170 32.150000 137.500000 $ 18-Dec-2018 18:07:43.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:43.718 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.838301 32.150000 137.500000 $ 18-Dec-2018 18:07:44.413 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:44.717 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.885300 32.150000 137.500000 $ 18-Dec-2018 18:07:45.413 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:45.619 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.873245 32.150000 137.500000 $ 18-Dec-2018 18:07:46.413 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:46.620 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.895254 32.150000 137.500000 $ 18-Dec-2018 18:07:47.413 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:47.621 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.861190 32.150000 137.500000 $ 18-Dec-2018 18:07:48.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:48.712 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.852160 32.150000 137.500000 $ 18-Dec-2018 18:07:49.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:49.718 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.861488 32.150000 137.500000 $ 18-Dec-2018 18:07:50.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:50.718 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.876553 32.150000 137.500000 $ 18-Dec-2018 18:07:51.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:51.620 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.860847 32.150000 137.500000 $ 18-Dec-2018 18:07:52.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:52.719 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.868834 32.150000 137.500000 $ 18-Dec-2018 18:07:53.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:53.719 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.883899 32.150000 137.500000 $ 18-Dec-2018 18:07:54.414 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:54.623 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.876448 32.150000 137.500000 $ 18-Dec-2018 18:07:55.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:55.719 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.884853 32.150000 137.500000 $ 18-Dec-2018 18:07:56.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:56.721 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.896699 32.150000 137.500000 $ 18-Dec-2018 18:07:57.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:57.719 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.884465 32.150000 137.500000 $ 18-Dec-2018 18:07:58.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:58.719 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.869341 32.150000 137.500000 $ 18-Dec-2018 18:07:59.416 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:07:59.624 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.864617 32.150000 137.500000 $ 18-Dec-2018 18:08:00.416 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:00.720 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.867597 32.150000 137.500000 $ 18-Dec-2018 18:08:01.416 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:01.720 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.877074 32.150000 137.500000 $ 18-Dec-2018 18:08:02.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:02.719 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.876180 32.150000 137.500000 $ 18-Dec-2018 18:08:03.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:03.623 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.860236 32.150000 137.500000 $ 18-Dec-2018 18:08:04.416 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:04.720 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.879235 32.150000 137.500000 $ 18-Dec-2018 18:08:05.415 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:05.622 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.856540 32.150000 137.500000 $ 18-Dec-2018 18:08:06.416 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:06.623 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.896163 32.150000 137.500000 $ 18-Dec-2018 18:08:07.416 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:07.623 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.867716 32.150000 137.500000 $ 18-Dec-2018 18:08:08.417 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:08.625 Start CP Mode PTH Message 768.203369 22.366667 52.933258 23.281414 $ 18-Dec-2018 18:08:08.828 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.867314 32.150000 128.500000 $ 18-Dec-2018 18:08:09.418 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:09.624 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.854216 32.150000 128.500000 $ 18-Dec-2018 18:08:10.419 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:10.625 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.856749 32.150000 128.500000 $ 18-Dec-2018 18:08:11.419 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:11.723 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.853366 32.150000 128.500000 $ 18-Dec-2018 18:08:12.418 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:12.626 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.871442 32.150000 128.500000 $ 18-Dec-2018 18:08:13.419 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:13.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.884450 32.150000 128.500000 $ 18-Dec-2018 18:08:14.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:14.724 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.877909 32.150000 128.500000 $ 18-Dec-2018 18:08:15.419 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:15.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.880502 32.150000 128.500000 $ 18-Dec-2018 18:08:16.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:16.725 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.868998 32.150000 128.500000 $ 18-Dec-2018 18:08:17.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:17.724 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.867940 32.150000 128.500000 $ 18-Dec-2018 18:08:18.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:18.724 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.858045 32.150000 128.500000 $ 18-Dec-2018 18:08:19.419 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:19.723 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.870503 32.150000 128.500000 $ 18-Dec-2018 18:08:20.419 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:20.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.879295 32.150000 128.500000 $ 18-Dec-2018 18:08:21.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:21.626 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.869966 32.150000 128.500000 $ 18-Dec-2018 18:08:22.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:22.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.859044 32.150000 128.500000 $ 18-Dec-2018 18:08:23.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:23.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.871278 32.150000 128.500000 $ 18-Dec-2018 18:08:24.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:24.724 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.868297 32.150000 128.500000 $ 18-Dec-2018 18:08:25.420 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:25.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.872827 32.150000 128.500000 $ 18-Dec-2018 18:08:26.421 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:26.627 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.869594 32.150000 128.500000 $ 18-Dec-2018 18:08:27.421 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:27.629 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.874318 32.150000 128.500000 $ 18-Dec-2018 18:08:28.422 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:28.726 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.875778 32.150000 128.500000 $ 18-Dec-2018 18:08:29.422 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:29.630 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.859193 32.150000 128.500000 $ 18-Dec-2018 18:08:30.422 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:30.629 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.860191 32.150000 128.500000 $ 18-Dec-2018 18:08:31.422 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:31.726 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.883765 32.150000 128.500000 $ 18-Dec-2018 18:08:32.422 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:32.726 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.882170 32.150000 128.500000 $ 18-Dec-2018 18:08:33.422 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:33.628 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.881455 32.150000 128.500000 $ 18-Dec-2018 18:08:34.423 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:34.630 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.872127 32.150000 128.500000 $ 18-Dec-2018 18:08:35.423 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:35.630 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.879429 32.150000 128.500000 $ 18-Dec-2018 18:08:36.434 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:36.642 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.881574 32.150000 128.500000 $ 18-Dec-2018 18:08:37.435 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:37.642 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.880621 32.150000 128.500000 $ 18-Dec-2018 18:08:38.435 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:38.642 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.878475 32.150000 128.500000 $ 18-Dec-2018 18:08:39.436 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:39.734 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.878892 32.150000 128.500000 $ 18-Dec-2018 18:08:40.437 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:40.646 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.862888 32.150000 128.500000 $ 18-Dec-2018 18:08:41.438 Start CP Mode Didn't get CR/LF response, trying again $ 18-Dec-2018 18:08:40.542 Start CP Mode Unparsed SBE41 Message S> $ 18-Dec-2018 18:08:41.860 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.888936 32.150000 128.500000 $ 18-Dec-2018 18:08:42.438 Start CP Mode Got CR/LF response, sending startprofile $ 18-Dec-2018 18:08:42.742 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.886671 32.150000 128.500000 $ 18-Dec-2018 18:08:43.438 Start CP Mode Didn't get startprofile response, retrying $ 18-Dec-2018 18:08:43.459 Start CP Mode Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:08:43.557 Start CP Mode Unparsed SBE41 Message S>startprofile5 $ 18-Dec-2018 18:08:43.881 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.877357 32.150000 128.500000 $ 18-Dec-2018 18:08:44.438 Start CP Mode Didn't get startprofile response, retrying $ 18-Dec-2018 18:08:44.541 Start CP Mode Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:08:44.748 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.871784 32.150000 128.500000 $ 18-Dec-2018 18:08:45.439 Start CP Mode Didn't get startprofile response, retrying $ 18-Dec-2018 18:08:45.543 Start CP Mode Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:08:45.847 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.861920 32.150000 128.500000 $ 18-Dec-2018 18:08:46.439 Start CP Mode Didn't get startprofile response, retrying $ 18-Dec-2018 18:08:46.541 Start CP Mode Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:08:46.845 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.886611 32.150000 128.500000 $ 18-Dec-2018 18:08:47.439 Start CP Mode Didn't get startprofile response, retrying $ 18-Dec-2018 18:08:47.541 Start CP Mode Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:08:47.336 Start CP Mode Unparsed SBE41 Message profile started, pump delay = 5 seconds $ 18-Dec-2018 18:08:47.865 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.880323 32.150000 128.500000 $ 18-Dec-2018 18:08:48.438 Start CP Mode Got startprofile response $ 18-Dec-2018 18:08:48.443 Start CP Mode Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:08:48.545 Start CP Mode Starting valve open $ 18-Dec-2018 18:08:48.848 Start CP Mode Normal State Exit $ 18-Dec-2018 18:08:48.852 Start CP Mode RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.859044 32.150000 128.500000 $ 18-Dec-2018 18:08:49.438 DeAnchor State Entry $ 18-Dec-2018 18:08:49.545 DeAnchor Deanchor JV = 200000.0 $ 18-Dec-2018 18:08:49.549 DeAnchor Initializing SBE 41 LPF $ 18-Dec-2018 18:08:49.754 DeAnchor Starting valve open $ 18-Dec-2018 18:08:50.063 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.859014 32.150000 128.500000 $ 18-Dec-2018 18:08:50.643 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.884421 32.150000 128.500000 $ 18-Dec-2018 18:08:51.642 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.871233 32.150000 128.500000 $ 18-Dec-2018 18:08:52.643 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.813208 32.150000 128.500000 $ 18-Dec-2018 18:08:53.808 DeAnchor Error parsing pressure in SBE41CTD.parse2 2 commas $ 18-Dec-2018 18:08:53.074 DeAnchor Unparsed SBE41 Message S> 25.91, 21.5299, 37.9471 $ 18-Dec-2018 18:08:54.125 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.980000 121.655434 32.150000 128.500000 $ 18-Dec-2018 18:08:54.072 DeAnchor SBE41 Message 25.39, 21.5327, 37.9443 25.389999 24.980006 -0.000001 -0.410000 -0.205000 -0.000000 1.000000 $ 18-Dec-2018 18:08:54.771 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.389999 121.403828 32.150000 128.500000 $ 18-Dec-2018 18:08:55.071 DeAnchor SBE41 Message 24.94, 21.5336, 37.9428 24.940001 24.981208 -0.000149 0.449999 0.020000 -0.000005 1.000000 $ 18-Dec-2018 18:08:55.772 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.940001 121.237203 32.150000 128.500000 $ 18-Dec-2018 18:08:56.070 DeAnchor SBE41 Message 24.95, 21.5325, 37.9330 24.950001 24.991435 -0.001414 -0.010000 0.219999 -0.000034 1.000000 $ 18-Dec-2018 18:08:56.673 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.950001 121.030822 32.150000 128.500000 $ 18-Dec-2018 18:08:57.067 DeAnchor SBE41 Message 24.95, 21.5323, 37.9461 24.950001 25.022642 -0.005272 0.000000 -0.005000 -0.000116 1.000000 $ 18-Dec-2018 18:08:57.673 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.950001 121.054873 32.150000 128.500000 $ 18-Dec-2018 18:08:58.069 DeAnchor SBE41 Message 24.96, 21.5325, 37.9475 24.959999 25.065728 -0.010600 -0.009998 -0.004999 -0.000243 1.000000 $ 18-Dec-2018 18:08:58.674 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.959999 120.755762 32.150000 128.500000 $ 18-Dec-2018 18:08:59.066 DeAnchor SBE41 Message 24.95, 21.5326, 37.9465 24.950001 25.081875 -0.012601 0.009998 0.000000 -0.000354 1.000000 $ 18-Dec-2018 18:08:59.771 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.950001 120.626777 32.150000 128.500000 $ 18-Dec-2018 18:09:00.064 DeAnchor SBE41 Message 24.96, 21.5332, 37.9464 24.959999 25.049219 -0.008569 -0.009998 0.000000 -0.000393 1.000000 $ 18-Dec-2018 18:09:00.672 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.959999 120.426655 32.150000 128.500000 $ 18-Dec-2018 18:09:01.064 DeAnchor SBE41 Message 24.96, 21.5343, 37.9456 24.959999 24.996884 -0.002099 0.000000 -0.004999 -0.000364 1.000000 $ 18-Dec-2018 18:09:01.673 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.959999 120.345175 32.150000 128.500000 $ 18-Dec-2018 18:09:02.063 DeAnchor SBE41 Message 25.69, 21.5339, 37.9462 25.690001 24.963960 0.001978 -0.730001 -0.365001 -0.000307 1.000000 $ 18-Dec-2018 18:09:02.674 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.690001 120.183662 32.150000 128.500000 $ 18-Dec-2018 18:09:03.062 DeAnchor SBE41 Message 25.91, 21.5347, 37.9455 25.910000 24.957366 0.002951 -0.219999 -0.475000 -0.000255 1.000000 $ 18-Dec-2018 18:09:03.672 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.910000 120.092720 32.150000 128.500000 $ 18-Dec-2018 18:09:04.062 DeAnchor SBE41 Message 25.91, 21.5351, 37.8269 25.910000 24.979182 0.001527 0.000000 -0.110000 -0.000230 1.000000 $ 18-Dec-2018 18:09:04.672 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.910000 119.824916 32.150000 128.500000 $ 18-Dec-2018 18:09:05.061 DeAnchor SBE41 Message 25.89, 21.5356, 37.9269 25.889999 25.065147 -0.005239 0.020000 0.010000 -0.000278 1.000000 $ 18-Dec-2018 18:09:05.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.889999 119.673625 32.150000 128.500000 $ 18-Dec-2018 18:09:06.057 DeAnchor SBE41 Message 25.91, 21.5358, 37.9464 25.910000 25.251973 -0.023014 -0.020000 0.000000 -0.000456 1.000000 $ 18-Dec-2018 18:09:06.770 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.910000 119.463146 32.150000 128.500000 $ 18-Dec-2018 18:09:07.058 DeAnchor SBE41 Message 25.90, 21.5347, 37.9481 25.900000 25.505592 -0.052391 0.010000 -0.005000 -0.000787 1.000000 $ 18-Dec-2018 18:09:07.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.900000 119.307667 32.150000 128.500000 $ 18-Dec-2018 18:09:08.056 DeAnchor SBE41 Message 25.00, 21.5358, 37.9474 25.000000 25.727778 -0.083925 0.900000 0.455000 -0.001222 1.000000 $ 18-Dec-2018 18:09:08.670 DeAnchor PTH Message 769.101562 22.258333 52.879852 23.292139 $ 18-Dec-2018 18:09:08.874 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 25.000000 119.111210 6.425000 629.000000 $ 18-Dec-2018 18:09:09.058 DeAnchor SBE41 Message 24.28, 21.5365, 37.9472 24.280001 25.849451 -0.105469 0.719999 0.809999 -0.001682 1.000000 $ 18-Dec-2018 18:09:09.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.280001 118.867606 6.425000 629.000000 $ 18-Dec-2018 18:09:10.055 DeAnchor SBE41 Message 24.28, 21.5377, 37.9459 24.280001 25.863835 -0.111341 0.000000 0.360000 -0.002101 1.000000 $ 18-Dec-2018 18:09:10.770 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.280001 118.817419 6.425000 629.000000 $ 18-Dec-2018 18:09:11.054 DeAnchor SBE41 Message 24.29, 21.5373, 37.9469 24.290001 25.754571 -0.098653 -0.010000 -0.005000 -0.002416 1.000000 $ 18-Dec-2018 18:09:11.676 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.290001 118.569106 6.425000 629.000000 $ 18-Dec-2018 18:09:12.053 DeAnchor SBE41 Message 24.29, 21.5376, 37.9473 24.290001 25.478109 -0.061759 0.000000 -0.005000 -0.002552 1.000000 $ 18-Dec-2018 18:09:12.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.290001 118.334129 6.425000 629.000000 $ 18-Dec-2018 18:09:13.053 DeAnchor SBE41 Message 24.28, 21.5378, 37.9470 24.280001 25.065916 -0.000128 0.010000 0.005000 -0.002460 1.000000 $ 18-Dec-2018 18:09:13.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.280001 118.117392 6.425000 629.000000 $ 18-Dec-2018 18:09:14.053 DeAnchor SBE41 Message 24.29, 21.5386, 37.9473 24.290001 24.665057 0.072591 -0.010000 0.000000 -0.002173 1.000000 $ 18-Dec-2018 18:09:14.679 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.290001 117.956370 6.425000 629.000000 $ 18-Dec-2018 18:09:15.051 DeAnchor SBE41 Message 24.28, 21.5381, 37.9437 24.280001 24.410822 0.135443 0.010000 0.000000 -0.001783 1.000000 $ 18-Dec-2018 18:09:15.672 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.280001 117.801160 6.425000 629.000000 $ 18-Dec-2018 18:09:16.049 DeAnchor SBE41 Message 24.30, 21.5391, 37.9467 24.299999 24.310395 0.175375 -0.019999 -0.004999 -0.001372 1.000000 $ 18-Dec-2018 18:09:16.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.299999 117.656752 6.425000 629.000000 $ 18-Dec-2018 18:09:17.048 DeAnchor SBE41 Message 24.29, 21.5395, 37.9474 24.290001 24.288298 0.193165 0.009998 -0.005000 -0.000976 1.000000 $ 18-Dec-2018 18:09:17.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.290001 117.577866 6.425000 629.000000 $ 18-Dec-2018 18:09:18.047 DeAnchor SBE41 Message 24.28, 21.5391, 37.9476 24.280001 24.286111 0.195193 0.010000 0.009999 -0.000601 1.000000 $ 18-Dec-2018 18:09:18.771 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.280001 117.239594 6.425000 629.000000 $ 18-Dec-2018 18:09:19.046 DeAnchor SBE41 Message 24.29, 21.5401, 37.9468 24.290001 24.286575 0.181582 -0.010000 0.000000 -0.000243 1.000000 $ 18-Dec-2018 18:09:19.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.290001 117.140397 6.425000 629.000000 $ 18-Dec-2018 18:09:20.045 DeAnchor SBE41 Message 24.29, 21.5399, 37.9467 24.290001 24.288065 0.147170 0.000000 -0.005000 0.000101 1.000000 $ 18-Dec-2018 18:09:20.768 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.290001 116.959587 6.425000 629.000000 $ 18-Dec-2018 18:09:21.044 DeAnchor SBE41 Message 24.14, 21.5402, 37.9476 24.139999 24.289230 0.096034 0.150002 0.075001 0.000435 1.000000 $ 18-Dec-2018 18:09:21.771 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 24.139999 116.816178 6.425000 629.000000 $ 18-Dec-2018 18:09:22.042 DeAnchor SBE41 Message 23.23, 21.5405, 37.9481 23.230000 24.288442 0.046560 0.910000 0.530001 0.000766 1.000000 $ 18-Dec-2018 18:09:22.770 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 23.230000 116.638616 6.425000 629.000000 $ 18-Dec-2018 18:09:23.043 DeAnchor SBE41 Message 22.95, 21.5411, 37.9478 22.950001 24.280613 0.016096 0.279999 0.594999 0.001101 1.000000 $ 18-Dec-2018 18:09:23.768 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.950001 116.557077 6.425000 629.000000 $ 18-Dec-2018 18:09:24.041 DeAnchor SBE41 Message 22.96, 21.5413, 37.9481 22.959999 24.238146 0.008930 -0.009998 0.135000 0.001465 1.000000 $ 18-Dec-2018 18:09:24.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 116.333321 6.425000 629.000000 $ 18-Dec-2018 18:09:25.041 DeAnchor SBE41 Message 22.95, 21.5421, 37.9477 22.950001 24.100593 0.023204 0.009998 0.000000 0.001911 1.000000 $ 18-Dec-2018 18:09:25.770 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.950001 116.244167 6.425000 629.000000 $ 18-Dec-2018 18:09:26.038 DeAnchor SBE41 Message 22.96, 21.5421, 37.9479 22.959999 23.827784 0.056666 -0.009998 0.000000 0.002523 1.000000 $ 18-Dec-2018 18:09:26.671 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 116.024390 6.425000 629.000000 $ 18-Dec-2018 18:09:27.037 DeAnchor SBE41 Message 22.96, 21.5421, 37.9474 22.959999 23.478540 0.099919 0.000000 -0.004999 0.003381 1.000000 $ 18-Dec-2018 18:09:27.670 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 115.869269 6.425000 629.000000 $ 18-Dec-2018 18:09:28.036 DeAnchor SBE41 Message 22.96, 21.5426, 37.9479 22.959999 23.183667 0.136593 0.000000 0.000000 0.004535 1.000000 $ 18-Dec-2018 18:09:28.672 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 115.555584 6.425000 629.000000 $ 18-Dec-2018 18:09:29.036 DeAnchor SBE41 Message 22.96, 21.5430, 37.9480 22.959999 23.021642 0.156808 0.000000 0.000000 0.006063 1.000000 $ 18-Dec-2018 18:09:29.675 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 115.415186 6.425000 629.000000 $ 18-Dec-2018 18:09:30.036 DeAnchor SBE41 Message 22.96, 21.5438, 37.9477 22.959999 22.967238 0.163465 0.000000 0.000000 0.008197 1.000000 $ 18-Dec-2018 18:09:30.768 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 115.183100 6.425000 629.000000 $ 18-Dec-2018 18:09:31.033 DeAnchor SBE41 Message 22.97, 21.5429, 37.9487 22.969999 22.958315 0.163603 -0.010000 -0.005000 0.011655 1.000000 $ 18-Dec-2018 18:09:31.672 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.969999 114.975780 6.425000 629.000000 $ 18-Dec-2018 18:09:32.033 DeAnchor SBE41 Message 22.95, 21.5435, 37.9481 22.950001 22.958934 0.158252 0.019999 0.004999 0.019226 1.000000 $ 18-Dec-2018 18:09:32.772 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.950001 114.866197 6.425000 629.000000 $ 18-Dec-2018 18:09:33.030 DeAnchor SBE41 Message 22.96, 21.5439, 37.9478 22.959999 22.959969 0.141078 -0.009998 0.005000 0.058796 1.000000 $ 18-Dec-2018 18:09:33.770 DeAnchor RecMode true, PID Off, BE Ext'g, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.959999 114.619777 6.425000 629.000000 $ 18-Dec-2018 18:09:34.440 DeAnchor Deanchor velocity (slope) threshold exceeded $ 18-Dec-2018 18:09:34.031 DeAnchor SBE41 Message 22.61, 21.5441, 37.9469 22.610001 22.960752 0.107217 0.349998 0.170000 0.062908 1.000000 $ 18-Dec-2018 18:09:34.775 DeAnchor Normal State Exit $ 18-Dec-2018 18:09:34.780 DeAnchor RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 22.610001 114.464954 6.425000 629.000000 $ 18-Dec-2018 18:09:35.441 Ascend State Entry $ 18-Dec-2018 18:09:35.563 Ascend Starting valve open $ 18-Dec-2018 18:09:35.665 Ascend Skipping ascend table depth = 100 $ 18-Dec-2018 18:09:35.767 Ascend Skipping ascend table depth = 95 $ 18-Dec-2018 18:09:35.869 Ascend Skipping ascend table depth = 90 $ 18-Dec-2018 18:09:35.971 Ascend Skipping ascend table depth = 85 $ 18-Dec-2018 18:09:36.076 Ascend Skipping ascend table depth = 80 $ 18-Dec-2018 18:09:36.178 Ascend Skipping ascend table depth = 75 $ 18-Dec-2018 18:09:36.280 Ascend Skipping ascend table depth = 70 $ 18-Dec-2018 18:09:36.382 Ascend Skipping ascend table depth = 65 $ 18-Dec-2018 18:09:36.484 Ascend Skipping ascend table depth = 60 $ 18-Dec-2018 18:09:36.586 Ascend Skipping ascend table depth = 55 $ 18-Dec-2018 18:09:36.689 Ascend Skipping ascend table depth = 50 $ 18-Dec-2018 18:09:36.695 Ascend Skipping ascend table depth = 45 $ 18-Dec-2018 18:09:36.797 Ascend Skipping ascend table depth = 40 $ 18-Dec-2018 18:09:36.997 Ascend Skipping ascend table depth = 35 $ 18-Dec-2018 18:09:37.002 Ascend Skipping ascend table depth = 30 $ 18-Dec-2018 18:09:37.105 Ascend Skipping ascend table depth = 25 $ 18-Dec-2018 18:09:44.921 Ascend Starting ISUS sample $ 18-Dec-2018 18:09:45.026 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156574, 22.61, 21.544, 37.95 $ 18-Dec-2018 18:09:45.033 Ascend MSC: Timeout for CommandWake $ 18-Dec-2018 18:09:35.030 Ascend Vel PID Values 0.100000 0.830000 0.827238 0.827238 248.498042 -58.399626 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:35.030 Ascend SBE41 Message 21.78, 21.5446, 37.9488 21.780001 22.960097 0.064100 0.830000 0.589999 0.066639 1.000000 $ 18-Dec-2018 18:09:45.778 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.780001 114.301696 6.425000 629.000000 $ 18-Dec-2018 18:09:45.891 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.4500172 $ 18-Dec-2018 18:09:45.994 Ascend MSC: OUT: W $ 18-Dec-2018 18:09:46.348 Ascend MSC: OUT: W $ 18-Dec-2018 18:09:36.075 Ascend Vel PID Values 0.100000 0.120001 0.122359 -0.704879 -5658.528094 246.897294 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:36.075 Ascend SBE41 Message 21.66, 21.5449, 37.9484 21.660000 22.947220 0.029230 0.120001 0.475000 0.069986 1.000000 $ 18-Dec-2018 18:09:37.100 Ascend Vel PID Values 0.100000 -0.010000 -0.009564 -0.131923 162333.832439 -5649.727821 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:37.100 Ascend SBE41 Message 21.67, 21.5452, 37.9488 21.670000 22.884870 0.016907 -0.010000 0.055000 0.073050 1.000000 $ 18-Dec-2018 18:09:44.917 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009531 -4706420.662458 162341.832502 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:44.917 Ascend SBE41 Message 21.67, 21.5456, 37.9484 21.670000 22.714533 0.031241 0.000000 -0.005000 0.073848 1.000000 $ 18-Dec-2018 18:09:44.917 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.009999 136484483.643987 -4706413.462476 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:44.917 Ascend SBE41 Message 21.66, 21.5458, 37.9487 21.660000 22.420185 0.066536 0.010000 0.005000 0.075816 1.000000 $ 18-Dec-2018 18:09:44.918 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009934 -3958048765.195516 136484491.643978 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:44.918 Ascend SBE41 Message 21.66, 21.5461, 37.9485 21.660000 22.084987 0.108075 0.000000 0.005000 0.079004 1.000000 $ 18-Dec-2018 18:09:44.919 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.010000 114783412427.197250 -3958048756.395498 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:44.919 Ascend SBE41 Message 21.67, 21.5468, 37.9482 21.670000 21.831988 0.139518 -0.010000 -0.005000 0.082961 1.000000 $ 18-Dec-2018 18:09:44.920 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019901 -3328718959104.288100 114783412434.397250 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:44.920 Ascend SBE41 Message 21.66, 21.5465, 37.9486 21.660000 21.708511 0.154918 0.010000 0.000000 0.087086 1.000000 $ 18-Dec-2018 18:09:44.920 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019868 96532849812260.891000 -3328718959095.488300 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:44.920 Ascend SBE41 Message 21.67, 21.5468, 37.9487 21.670000 21.671505 0.159433 -0.010000 0.000000 0.091022 1.000000 $ 18-Dec-2018 18:09:44.921 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019868 -2799452644554281.500000 96532849812268.094000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:44.921 Ascend SBE41 Message 21.66, 21.5469, 37.9482 21.660000 21.664756 0.158670 0.010000 0.000000 0.094629 1.000000 $ 18-Dec-2018 18:09:45.024 Ascend Vel PID Values 0.100000 -0.020000 -0.019901 -0.029835 81184126692072368.000000 -2799452644554272.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:45.024 Ascend SBE41 Message 21.68, 21.5473, 37.9489 21.680000 21.663854 0.151044 -0.020000 -0.005000 0.097688 1.000000 $ 18-Dec-2018 18:09:50.098 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.680000 114.226088 6.425000 629.000000 $ 18-Dec-2018 18:09:50.209 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.3128096 $ 18-Dec-2018 18:09:50.215 Ascend MSC: Timeout for CommandWake $ 18-Dec-2018 18:09:46.096 Ascend Vel PID Values 0.100000 0.010000 0.009901 0.029801 -2354339674070096900.000000 81184126692072368.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:46.096 Ascend SBE41 Message 21.67, 21.5473, 37.9491 21.670000 21.664242 0.129898 0.010000 -0.005000 0.099588 1.000000 $ 18-Dec-2018 18:09:50.757 Ascend MSC: RX: $ 18-Dec-2018 18:09:50.761 Ascend MSC: RX: $ 18-Dec-2018 18:09:50.961 Ascend MSC: RX: ACK $ 18-Dec-2018 18:09:50.965 Ascend MSC: Got ACK $ 18-Dec-2018 18:09:51.270 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.670000 114.212856 6.425000 629.000000 $ 18-Dec-2018 18:09:51.382 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1671328 $ 18-Dec-2018 18:09:51.485 Ascend MSC: OUT: W $ 18-Dec-2018 18:09:51.838 Ascend MSC: OUT: W $ 18-Dec-2018 18:09:47.028 Ascend Vel PID Values 0.100000 0.549999 0.548202 0.538302 68275850548032807000.000000 -2354339674070096900.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:47.028 Ascend SBE41 Message 21.12, 21.5483, 37.9487 21.120001 21.665050 0.093376 0.549999 0.280000 0.100076 1.000000 $ 18-Dec-2018 18:09:52.494 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 21.120001 114.222229 6.425000 629.000000 $ 18-Dec-2018 18:09:52.605 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2173806 $ 18-Dec-2018 18:09:48.060 Ascend Vel PID Values 0.100000 0.660002 0.659633 0.111431 -1979999665892951300000.000000 68275850548032807000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:48.060 Ascend SBE41 Message 20.46, 21.5481, 37.9493 20.459999 21.664681 0.051965 0.660002 0.605000 0.099156 1.000000 $ 18-Dec-2018 18:09:53.256 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.459999 114.244148 6.425000 629.000000 $ 18-Dec-2018 18:09:49.093 Ascend Vel PID Values 0.100000 0.059999 0.061996 -0.597637 57419990310895588000000.000000 -1979999665892951300000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:49.093 Ascend SBE41 Message 20.40, 21.5486, 37.9491 20.400000 21.649230 0.022593 0.059999 0.360001 0.097152 1.000000 $ 18-Dec-2018 18:09:54.159 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.400000 114.233091 6.425000 629.000000 $ 18-Dec-2018 18:09:54.610 Ascend MSC: Timeout for CommandWake $ 18-Dec-2018 18:09:50.014 Ascend Vel PID Values 0.100000 0.010000 0.010170 -0.051826 -1665179719015972100000000.000000 57419990310895588000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:50.014 Ascend SBE41 Message 20.39, 21.5494, 37.9486 20.389999 21.573604 0.016676 0.010000 0.035000 0.094623 1.000000 $ 18-Dec-2018 18:09:51.064 Ascend Vel PID Values 0.100000 -0.020000 -0.019900 -0.030070 48290211851463190000000000.000000 -1665179719015972100000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:51.064 Ascend SBE41 Message 20.41, 21.5490, 37.9495 20.410000 21.380105 0.036025 -0.020000 -0.005000 0.092313 1.000000 $ 18-Dec-2018 18:09:55.608 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.410000 114.246055 6.425000 629.000000 $ 18-Dec-2018 18:09:55.719 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1097965 $ 18-Dec-2018 18:09:55.824 Ascend MSC: OUT: W $ 18-Dec-2018 18:09:56.176 Ascend MSC: OUT: W $ 18-Dec-2018 18:09:56.278 Ascend MSC: RX: ACK $ 18-Dec-2018 18:09:56.282 Ascend MSC: Got ACK $ 18-Dec-2018 18:09:52.012 Ascend Vel PID Values 0.100000 0.000000 -0.000066 0.019834 -1400416143692432600000000000.000000 48290211851463190000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:52.012 Ascend SBE41 Message 20.41, 21.5498, 37.9490 20.410000 21.072657 0.073210 0.000000 -0.010000 0.091217 1.000000 $ 18-Dec-2018 18:09:56.829 Ascend MSC: RX: ACK $ 18-Dec-2018 18:09:56.833 Ascend MSC: Got ACK $ 18-Dec-2018 18:09:53.053 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000066 40612068167080544000000000000.000000 -1400416143692432600000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:53.053 Ascend SBE41 Message 20.41, 21.5500, 37.9491 20.410000 20.751414 0.112839 0.000000 0.000000 0.091879 1.000000 $ 18-Dec-2018 18:09:57.484 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.410000 114.250436 6.425000 629.000000 $ 18-Dec-2018 18:09:57.595 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8690010 $ 18-Dec-2018 18:09:54.010 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009967 -1177749976845335700000000000000.000000 40612068167080544000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:54.010 Ascend SBE41 Message 20.42, 21.5506, 37.9481 20.420000 20.529075 0.140412 -0.010000 -0.005000 0.094017 1.000000 $ 18-Dec-2018 18:09:55.059 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019901 34154749328514736000000000000000.000000 -1177749976845335700000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:55.059 Ascend SBE41 Message 20.41, 21.5505, 37.9491 20.410000 20.431300 0.152635 0.010000 0.000000 0.096729 1.000000 $ 18-Dec-2018 18:09:58.499 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.410000 114.843473 6.425000 629.000000 $ 18-Dec-2018 18:09:58.610 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0094003 $ 18-Dec-2018 18:09:58.716 Ascend MSC: OUT: CTD,1545156598,21.5505,37.9491,20.4100 $ 18-Dec-2018 18:09:56.009 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009901 -990487730526927390000000000000000.000000 34154749328514736000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:56.009 Ascend SBE41 Message 20.41, 21.5512, 37.9486 20.410000 20.408298 0.155450 0.000000 0.005000 0.099254 1.000000 $ 18-Dec-2018 18:09:59.085 Ascend MSC: RX: ACK $ 18-Dec-2018 18:09:59.187 Ascend MSC: Got ACK $ 18-Dec-2018 18:09:59.386 Ascend MSC: RX: ACK $ 18-Dec-2018 18:09:59.390 Ascend MSC: Got ACK $ 18-Dec-2018 18:09:57.032 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.009934 28724144185280894000000000000000000.000000 -990487730526927390000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:57.032 Ascend SBE41 Message 20.40, 21.5511, 37.9485 20.400000 20.408807 0.153466 0.010000 0.005000 0.101205 1.000000 $ 18-Dec-2018 18:10:00.138 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.400000 114.945412 6.425000 629.000000 $ 18-Dec-2018 18:10:00.249 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6321036 $ 18-Dec-2018 18:09:58.047 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019901 -833000181373145890000000000000000000.000000 28724144185280894000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:09:58.047 Ascend SBE41 Message 20.41, 21.5515, 37.9485 20.410000 20.411596 0.143739 -0.010000 0.000000 0.102487 1.000000 $ 18-Dec-2018 18:10:00.903 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 20.410000 115.170270 6.425000 629.000000 $ 18-Dec-2018 18:09:59.066 Ascend Vel PID Values 0.100000 0.459999 0.458435 0.468369 24157005259821230000000000000000000000.000000 -833000181373145890000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:09:59.066 Ascend SBE41 Message 19.95, 21.5514, 37.9495 19.950001 20.412453 0.119672 0.459999 0.224999 0.103075 1.000000 $ 18-Dec-2018 18:10:01.503 Ascend MSC: RX: ACK,CTD,1545156598,21.5505,37.9491,20.41 $ 18-Dec-2018 18:10:00.004 Ascend Vel PID Values 0.100000 0.610001 0.609499 0.151064 -700553152534815720000000000000000000000.000000 24157005259821230000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:00.004 Ascend SBE41 Message 19.34, 21.5524, 37.9488 19.340000 20.409775 0.081964 0.610001 0.535000 0.102986 1.000000 $ 18-Dec-2018 18:10:02.155 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 16 Pres, BP, BatV, BatI: 19.340000 115.247324 6.425000 629.000000 $ 18-Dec-2018 18:10:02.270 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0156262 $ 18-Dec-2018 18:10:02.375 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:10:02.477 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:10:02.982 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:10:02.999 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:10:03.198 Ascend Sending FLBB run command $ 18-Dec-2018 18:10:03.203 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:10:03.309 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:10:03.508 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:10:03.624 Ascend CTD post: 19.21 21.552 37.95 $ 18-Dec-2018 18:10:01.012 Ascend Vel PID Values 0.100000 0.130001 0.131598 -0.477901 20316041423509654000000000000000000000000.000000 -700553152534815720000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:01.012 Ascend SBE41 Message 19.21, 21.5524, 37.9491 19.209999 20.392715 0.044345 0.130001 0.370001 0.102225 1.000000 $ 18-Dec-2018 18:10:04.267 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.209999 115.243465 6.425000 629.000000 $ 18-Dec-2018 18:10:04.377 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1023410 $ 18-Dec-2018 18:10:04.483 Ascend MSC: OUT: W $ 18-Dec-2018 18:10:04.740 Ascend MSC: OUT: W $ 18-Dec-2018 18:10:02.051 Ascend Vel PID Values 0.100000 0.009998 0.010400 -0.121197 -589165201281779960000000000000000000000000.000000 20316041423509654000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:02.051 Ascend SBE41 Message 19.20, 21.5524, 37.9494 19.200001 20.324562 0.025281 0.009998 0.070000 0.100943 1.000000 $ 18-Dec-2018 18:10:03.097 Ascend Vel PID Values 0.100000 -0.009998 -0.009931 -0.020331 17085790837171619000000000000000000000000000.000000 -589165201281779960000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:03.097 Ascend SBE41 Message 19.21, 21.5532, 37.9491 19.209999 20.153916 0.034292 -0.009998 0.000000 0.099505 1.000000 $ 18-Dec-2018 18:10:05.436 Ascend Radiometer Message SATFI40287,-0.0038,-0.0006,-0.0075,-0.1931 $ 18-Dec-2018 18:10:05.649 Ascend Radiometer post: SATFI40287,-0.0038,-0.0006,-0.0075,-0.1931 $ 18-Dec-2018 18:10:04.062 Ascend Vel PID Values 0.100000 -0.010000 -0.010000 -0.000069 -495487934277976980000000000000000000000000000.000000 17085790837171619000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:04.062 Ascend SBE41 Message 19.22, 21.5533, 37.9494 19.219999 19.876705 0.065729 -0.010000 -0.009999 0.098438 1.000000 $ 18-Dec-2018 18:10:04.072 Ascend Optode Message %!4330,1532,270.416,21.669,29.256,29.188,36.274,7.086,528.2,465.4,137.3 $ 18-Dec-2018 18:10:06.214 Ascend Optode post: %!4330,1532,270.416,21.669,29.256,29.188,36.274,7.086,528.2,465.4,137.3 $ 18-Dec-2018 18:10:04.075 Ascend Optode Message # $ 18-Dec-2018 18:10:06.331 Ascend FLBB Message /99/99,99:99:99,695,2317,700,4130,535 $ 18-Dec-2018 18:10:06.541 Ascend FLBB post: /99/99,99:99:99,695,2317,700,4130,535 $ 18-Dec-2018 18:10:06.748 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.219999 115.129977 6.425000 629.000000 $ 18-Dec-2018 18:10:06.860 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4766618 $ 18-Dec-2018 18:10:06.963 Ascend MSC: RX: ACK $ 18-Dec-2018 18:10:07.066 Ascend MSC: Got ACK $ 18-Dec-2018 18:10:07.170 Ascend MSC: RX: ACK $ 18-Dec-2018 18:10:07.174 Ascend MSC: Got ACK $ 18-Dec-2018 18:10:05.074 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009967 14369150094061333000000000000000000000000000000.000000 -495487934277976980000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:05.074 Ascend SBE41 Message 19.22, 21.5538, 37.9489 19.219999 19.574976 0.103117 0.000000 -0.005000 0.098166 1.000000 $ 18-Dec-2018 18:10:07.921 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.219999 115.162894 6.425000 629.000000 $ 18-Dec-2018 18:10:08.033 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1683826 $ 18-Dec-2018 18:10:08.137 Ascend MSC: OUT: MODE,1 $ 18-Dec-2018 18:10:06.100 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.010000 -416705352727778640000000000000000000000000000000.000000 14369150094061333000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:06.100 Ascend SBE41 Message 19.21, 21.5537, 37.9495 19.209999 19.353432 0.130885 0.010000 0.005000 0.098948 1.000000 $ 18-Dec-2018 18:10:07.065 Ascend Vel PID Values 0.100000 0.009998 0.009998 0.000031 12084455229105579000000000000000000000000000000000.000000 -416705352727778640000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:07.065 Ascend SBE41 Message 19.20, 21.5542, 37.9493 19.200001 19.246867 0.144199 0.009998 0.009999 0.100737 1.000000 $ 18-Dec-2018 18:10:08.032 Ascend Vel PID Values 0.100000 -0.009998 -0.009932 -0.019930 -350449201644061790000000000000000000000000000000000.000000 12084455229105579000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:08.032 Ascend SBE41 Message 19.21, 21.5545, 37.9493 19.209999 19.216904 0.147589 -0.009998 0.000000 0.103094 1.000000 $ 18-Dec-2018 18:10:09.385 Ascend PTH Message 765.793701 22.408333 52.826447 23.302864 $ 18-Dec-2018 18:10:09.587 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.209999 115.151733 31.450000 172.500000 $ 18-Dec-2018 18:10:09.698 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6592832 $ 18-Dec-2018 18:10:09.804 Ascend MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:10:10.110 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 19.209999 115.125939 31.450000 172.500000 $ 18-Dec-2018 18:10:10.706 Ascend MSC: OUT: ACK $ 18-Dec-2018 18:10:08.995 Ascend Vel PID Values 0.100000 0.039999 0.039833 0.049765 10163026847677793000000000000000000000000000000000000.000000 -350449201644061790000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:08.995 Ascend SBE41 Message 19.17, 21.5549, 37.9492 19.170000 19.214062 0.145824 0.039999 0.015000 0.105421 1.000000 $ 18-Dec-2018 18:10:09.994 Ascend Vel PID Values 0.100000 0.530001 0.528370 0.488537 -294727778582655990000000000000000000000000000000000000.000000 10163026847677793000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:09.994 Ascend SBE41 Message 18.64, 21.5551, 37.9494 18.639999 19.213543 0.137435 0.530001 0.285000 0.107259 1.000000 $ 18-Dec-2018 18:10:11.041 Ascend Vel PID Values 0.100000 0.529999 0.529996 0.001626 8547105578897023800000000000000000000000000000000000000.000000 -294727778582655990000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:11.041 Ascend SBE41 Message 18.11, 21.5553, 37.9497 18.110001 19.208215 0.116960 0.529999 0.530000 0.108401 1.000000 $ 18-Dec-2018 18:10:12.052 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.110001 115.134999 31.450000 172.500000 $ 18-Dec-2018 18:10:12.164 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4586290 $ 18-Dec-2018 18:10:12.267 Ascend MSC: OUT: TS $ 18-Dec-2018 18:10:11.992 Ascend Vel PID Values 0.100000 0.060001 0.061565 -0.468431 -247866061788013700000000000000000000000000000000000000000.000000 8547105578897023800000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:11.992 Ascend SBE41 Message 18.05, 21.5557, 37.9497 18.049999 19.184946 0.085537 0.060001 0.295000 0.108895 1.000000 $ 18-Dec-2018 18:10:12.919 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.049999 114.989251 31.450000 172.500000 $ 18-Dec-2018 18:10:13.171 Ascend MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:10:13.036 Ascend Vel PID Values 0.100000 0.000000 0.000202 -0.061363 7188115791852397100000000000000000000000000000000000000000.000000 -247866061788013700000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:13.036 Ascend SBE41 Message 18.05, 21.5556, 37.9502 18.049999 19.103809 0.058251 0.000000 0.030001 0.108897 1.000000 $ 18-Dec-2018 18:10:13.821 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.049999 114.978045 31.450000 172.500000 $ 18-Dec-2018 18:10:13.990 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.010169 -208455357963719520000000000000000000000000000000000000000000.000000 7188115791852397100000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:13.990 Ascend SBE41 Message 18.06, 21.5565, 37.9487 18.059999 18.917526 0.053891 -0.010000 -0.005000 0.108842 1.000000 $ 18-Dec-2018 18:10:14.719 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.059999 114.984304 31.450000 172.500000 $ 18-Dec-2018 18:10:14.989 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019900 6045205380947866400000000000000000000000000000000000000000000.000000 -208455357963719520000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:14.989 Ascend SBE41 Message 18.05, 21.5564, 37.9498 18.049999 18.636985 0.075410 0.010000 0.000000 0.109054 1.000000 $ 18-Dec-2018 18:10:15.718 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.049999 114.968702 31.450000 172.500000 $ 18-Dec-2018 18:10:15.988 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019868 -175310956047488120000000000000000000000000000000000000000000000.000000 6045205380947866400000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:15.988 Ascend SBE41 Message 18.06, 21.5575, 37.9489 18.059999 18.353865 0.106733 -0.010000 0.000000 0.109529 1.000000 $ 18-Dec-2018 18:10:16.719 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.059999 114.945114 31.450000 172.500000 $ 18-Dec-2018 18:10:16.986 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009901 5084017725377155800000000000000000000000000000000000000000000000.000000 -175310956047488120000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:16.986 Ascend SBE41 Message 18.06, 21.5568, 37.9501 18.059999 18.162522 0.130071 0.000000 -0.005000 0.110075 1.000000 $ 18-Dec-2018 18:10:17.719 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.059999 114.962325 31.450000 172.500000 $ 18-Dec-2018 18:10:17.985 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.010000 -147436514035937530000000000000000000000000000000000000000000000000.000000 5084017725377155800000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:17.985 Ascend SBE41 Message 18.05, 21.5571, 37.9500 18.049999 18.078894 0.140375 0.010000 0.005000 0.108502 1.000000 $ 18-Dec-2018 18:10:18.719 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.049999 114.976585 31.450000 172.500000 $ 18-Dec-2018 18:10:18.984 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019901 4275658907042188900000000000000000000000000000000000000000000000000.000000 -147436514035937530000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:18.984 Ascend SBE41 Message 18.06, 21.5573, 37.9501 18.059999 18.057601 0.142361 -0.010000 0.000000 0.107290 1.000000 $ 18-Dec-2018 18:10:19.517 Ascend MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:10:19.821 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.059999 114.979297 31.450000 172.500000 $ 18-Dec-2018 18:10:19.985 Ascend Vel PID Values 0.100000 0.029999 0.029866 0.039800 -123994108304223470000000000000000000000000000000000000000000000000000.000000 4275658907042188900000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:19.985 Ascend SBE41 Message 18.03, 21.5575, 37.9501 18.030001 18.055721 0.139706 0.029999 0.009999 0.106596 1.000000 $ 18-Dec-2018 18:10:20.719 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 18.030001 114.979774 31.450000 172.500000 $ 18-Dec-2018 18:10:21.170 Ascend MSC: OUT: SL $ 18-Dec-2018 18:10:20.983 Ascend Vel PID Values 0.100000 0.480001 0.478504 0.448638 3595829140822480900000000000000000000000000000000000000000000000000000.000000 -123994108304223470000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:20.983 Ascend SBE41 Message 17.55, 21.5578, 37.9502 17.549999 18.056305 0.129573 0.480001 0.255000 0.106268 1.000000 $ 18-Dec-2018 18:10:21.826 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 17 Pres, BP, BatV, BatI: 17.549999 114.988074 31.450000 172.500000 $ 18-Dec-2018 18:10:22.173 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:10:22.177 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:10:22.877 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:10:22.893 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:10:22.996 Ascend Sending FLBB run command $ 18-Dec-2018 18:10:23.098 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:10:23.300 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:10:23.306 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:10:23.506 Ascend MSC: RX: 0x71AC,A,02/06/2012 00:35:48,0,-1.00,-1.0000,-1.0000,296,196,1,78,21.51,54.85,11.572,5.284e-01,10848.00,2244.00,1125.50,12.67,-2FF6423A455949734EA1549C5B586274699C704075E479E97C2E7CBD7B6578FE755070F96C8D68A6654862AE610E604260646165633765C369276D677209773F7D4A835C89708F35945798BD9B8B9D0D9CDA9B0E97B892EF8D3E868D7FED794373086D0B67EC631C5F025B6658A65614542A52A4517450BA5070506C,6796.2 $ 18-Dec-2018 18:10:23.615 Ascend MSC: Data: 0x71AC,A,02/06/2012 00:35:48,0,-1.00,-1.0000,-1.0000,296,196,1,78,21.51,54.85,11.572,5.284e-01,10848.00,2244.00,1125.50,12.67,-2FF6423A455949734EA1549C5B586274699C704075E479E97C2E7CBD7B6578FE755070F96C8D68A6654862AE610E604260646165633765C369276D677209773F7D4A835C89708F35945798BD9B8B9D0D9CDA9B0E97B892EF8D3E868D7FED794373086D0B67EC631C5F025B6658A65614542A52A4517450BA5070506C,6796.2 $ 18-Dec-2018 18:10:23.726 Ascend MSC post: 6796.2 $ 18-Dec-2018 18:10:23.843 Ascend CTD post: 17.01 21.558 37.95 $ 18-Dec-2018 18:10:21.999 Ascend Vel PID Values 0.100000 0.539999 0.539797 0.061293 -104279045083851940000000000000000000000000000000000000000000000000000000.000000 3595829140822480900000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:21.999 Ascend SBE41 Message 17.01, 21.5581, 37.9503 17.010000 18.054316 0.106754 0.539999 0.510000 0.105984 1.000000 $ 18-Dec-2018 18:10:22.992 Ascend Vel PID Values 0.100000 0.100000 0.101464 -0.438333 3024092307431706300000000000000000000000000000000000000000000000000000000.000000 -104279045083851940000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:22.992 Ascend SBE41 Message 16.91, 21.5584, 37.9505 16.910000 18.036221 0.074283 0.100000 0.320000 0.105586 1.000000 $ 18-Dec-2018 18:10:24.529 Ascend Radiometer Message SATFI40287,-0.0045,-0.0001,-0.0072,-0.1745 $ 18-Dec-2018 18:10:24.740 Ascend Radiometer post: SATFI40287,-0.0045,-0.0001,-0.0072,-0.1745 $ 18-Dec-2018 18:10:23.990 Ascend Optode Message 4330,1532,270.408,21.667,29.257,29.189,36.275,7.087,528.2,465.2,137.4 $ 18-Dec-2018 18:10:24.957 Ascend Optode post: 4330,1532,270.408,21.667,29.257,29.189,36.275,7.087,528.2,465.2,137.4 $ 18-Dec-2018 18:10:23.990 Ascend Optode Message # $ 18-Dec-2018 18:10:23.991 Ascend Vel PID Values 0.100000 0.000000 0.000335 -0.101129 -87698676915519490000000000000000000000000000000000000000000000000000000000.000000 3024092307431706300000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:23.991 Ascend SBE41 Message 16.91, 21.5590, 37.9503 16.910000 17.963543 0.048255 0.000000 0.050000 0.105196 1.000000 $ 18-Dec-2018 18:10:25.422 Ascend FLBB Message /99/99,99:99:99,695,2313,700,4130,535 $ 18-Dec-2018 18:10:25.630 Ascend FLBB post: /99/99,99:99:99,695,2313,700,4130,535 $ 18-Dec-2018 18:10:25.935 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.910000 114.962697 31.450000 172.500000 $ 18-Dec-2018 18:10:26.047 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.8768139 $ 18-Dec-2018 18:10:26.055 Ascend MSC: Done Sampling. $ 18-Dec-2018 18:10:26.156 Ascend Starting pH sample $ 18-Dec-2018 18:10:26.355 Ascend MSC: OUT: W $ 18-Dec-2018 18:10:26.610 Ascend MSC: OUT: W $ 18-Dec-2018 18:10:25.062 Ascend Vel PID Values 0.100000 -0.010000 -0.009966 -0.010302 2543261630550065300000000000000000000000000000000000000000000000000000000000.000000 -87698676915519490000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:25.062 Ascend SBE41 Message 16.92, 21.5593, 37.9503 16.920000 17.789266 0.046145 -0.010000 -0.005000 0.105095 1.000000 $ 18-Dec-2018 18:10:26.046 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009933 -73754587285951895000000000000000000000000000000000000000000000000000000000000.000000 2543261630550065300000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:26.046 Ascend SBE41 Message 16.92, 21.5596, 37.9502 16.920000 17.518484 0.069292 0.000000 -0.005000 0.105235 1.000000 $ 18-Dec-2018 18:10:27.411 Ascend MSC: RX: ACK $ 18-Dec-2018 18:10:27.415 Ascend MSC: Got ACK $ 18-Dec-2018 18:10:27.816 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.920000 116.192773 31.450000 172.500000 $ 18-Dec-2018 18:10:27.929 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8745562 $ 18-Dec-2018 18:10:28.033 Ascend MSC: OUT: MODE,2 $ 18-Dec-2018 18:10:27.062 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.010000 2138883031292605200000000000000000000000000000000000000000000000000000000000000.000000 -73754587285951895000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:27.062 Ascend SBE41 Message 16.91, 21.5600, 37.9501 16.910000 17.235880 0.101621 0.010000 0.005000 0.105651 1.000000 $ 18-Dec-2018 18:10:28.388 Ascend MSC: RX: ACK $ 18-Dec-2018 18:10:28.490 Ascend MSC: Got ACK $ 18-Dec-2018 18:10:28.033 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019901 -62027607907485552000000000000000000000000000000000000000000000000000000000000000.000000 2138883031292605200000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:28.033 Ascend SBE41 Message 16.92, 21.5607, 37.9496 16.920000 17.036966 0.126013 -0.010000 0.000000 0.105965 1.000000 $ 18-Dec-2018 18:10:29.144 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.920000 116.175279 31.450000 172.500000 $ 18-Dec-2018 18:10:29.255 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3207924 $ 18-Dec-2018 18:10:29.360 Ascend MSC: RX: ACK,MODE,2 $ 18-Dec-2018 18:10:29.039 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019868 1798800629317081000000000000000000000000000000000000000000000000000000000000000000.000000 -62027607907485552000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:29.039 Ascend SBE41 Message 16.91, 21.5600, 37.9505 16.910000 16.945370 0.137440 0.010000 0.000000 0.105788 1.000000 $ 18-Dec-2018 18:10:30.013 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.910000 116.146833 31.450000 172.500000 $ 18-Dec-2018 18:10:29.975 Ascend Vel PID Values 0.100000 -0.020000 -0.019901 -0.029835 -52165218250195345000000000000000000000000000000000000000000000000000000000000000000.000000 1798800629317081000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:29.975 Ascend SBE41 Message 16.93, 21.5605, 37.9497 16.930000 16.920024 0.140342 -0.020000 -0.005000 0.105164 1.000000 $ 18-Dec-2018 18:10:30.814 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.930000 116.138905 31.450000 172.500000 $ 18-Dec-2018 18:10:31.264 Ascend MSC: OUT: ACK $ 18-Dec-2018 18:10:30.972 Ascend Vel PID Values 0.100000 0.020000 0.019868 0.039768 1512791329255665000000000000000000000000000000000000000000000000000000000000000000000.000000 -52165218250195345000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:30.972 Ascend SBE41 Message 16.91, 21.5610, 37.9501 16.910000 16.916453 0.138537 0.020000 0.000000 0.104406 1.000000 $ 18-Dec-2018 18:10:31.922 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.910000 116.113275 31.450000 172.500000 $ 18-Dec-2018 18:10:32.265 Ascend MSC: RX: NAK,UnrecognizedCmdStr: CK $ 18-Dec-2018 18:10:32.077 Ascend Vel PID Values 0.100000 0.410000 0.408702 0.388834 -43870948548414286000000000000000000000000000000000000000000000000000000000000000000000.000000 1512791329255665000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:32.077 Ascend SBE41 Message 16.50, 21.5605, 37.9507 16.500000 16.916065 0.129572 0.410000 0.215000 0.103972 1.000000 $ 18-Dec-2018 18:10:32.918 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 16.500000 116.084620 31.450000 172.500000 $ 18-Dec-2018 18:10:33.265 Ascend MSC: OUT: TS $ 18-Dec-2018 18:10:33.028 Ascend Vel PID Values 0.100000 0.560000 0.559499 0.150797 1272257507904014400000000000000000000000000000000000000000000000000000000000000000000000.000000 -43870948548414286000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:33.028 Ascend SBE41 Message 15.94, 21.5608, 37.9502 15.940000 16.915068 0.108115 0.560000 0.485000 0.104001 1.000000 $ 18-Dec-2018 18:10:33.919 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 18 Pres, BP, BatV, BatI: 15.940000 116.055459 31.450000 172.500000 $ 18-Dec-2018 18:10:34.267 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:10:34.271 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:10:34.873 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:10:34.889 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:10:34.992 Ascend Sending FLBB run command $ 18-Dec-2018 18:10:35.095 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:10:35.200 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:10:35.399 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:10:35.404 Ascend MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:10:35.617 Ascend CTD post: 15.79 21.561 37.95 $ 18-Dec-2018 18:10:34.031 Ascend Vel PID Values 0.100000 0.150000 0.151363 -0.408136 -36895467729216419000000000000000000000000000000000000000000000000000000000000000000000000.000000 1272257507904014400000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:34.031 Ascend SBE41 Message 15.79, 21.5613, 37.9508 15.790000 16.902534 0.076163 0.150000 0.355000 0.104229 1.000000 $ 18-Dec-2018 18:10:34.988 Ascend Vel PID Values 0.100000 0.000000 0.000501 -0.150862 1069968564147276200000000000000000000000000000000000000000000000000000000000000000000000000.000000 -36895467729216419000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:34.988 Ascend SBE41 Message 15.79, 21.5622, 37.9504 15.790000 16.842189 0.048672 0.000000 0.075000 0.104370 1.000000 $ 18-Dec-2018 18:10:36.310 Ascend Radiometer Message SATFI40287,-0.0057,0.0007,-0.0064,-0.1758 $ 18-Dec-2018 18:10:36.523 Ascend Radiometer post: SATFI40287,-0.0057,0.0007,-0.0064,-0.1758 $ 18-Dec-2018 18:10:36.058 Ascend Optode Message 4330,1532,270.415,21.669,29.256,29.187,36.275,7.088,528.2,464.9,137.3 $ 18-Dec-2018 18:10:36.742 Ascend Optode post: 4330,1532,270.415,21.669,29.256,29.187,36.275,7.088,528.2,464.9,137.3 $ 18-Dec-2018 18:10:36.058 Ascend Optode Message # $ 18-Dec-2018 18:10:36.059 Ascend Vel PID Values 0.100000 0.010000 0.009968 0.009466 -31029088360271009000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1069968564147276200000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:36.059 Ascend SBE41 Message 15.78, 21.5617, 37.9504 15.780000 16.685131 0.043496 0.010000 0.005000 0.104492 1.000000 $ 18-Dec-2018 18:10:37.508 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.780000 116.089255 31.450000 172.500000 $ 18-Dec-2018 18:10:37.621 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.3570186 $ 18-Dec-2018 18:10:37.724 Ascend FLBB Message /99/99,99:99:99,695,2328,700,4130,535 $ 18-Dec-2018 18:10:37.835 Ascend FLBB post: /99/99,99:99:99,695,2328,700,4130,535 $ 18-Dec-2018 18:10:36.974 Ascend Vel PID Values 0.100000 -0.020000 -0.019901 -0.029868 899843562447859220000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -31029088360271009000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:36.974 Ascend SBE41 Message 15.80, 21.5621, 37.9509 15.800000 16.427433 0.064039 -0.020000 -0.005000 0.104881 1.000000 $ 18-Dec-2018 18:10:38.488 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.800000 116.606742 31.450000 172.500000 $ 18-Dec-2018 18:10:37.966 Ascend Vel PID Values 0.100000 -0.010000 -0.010033 0.009867 -26095463310987919000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 899843562447859220000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:37.966 Ascend SBE41 Message 15.81, 21.5626, 37.9503 15.810000 16.144509 0.095904 -0.010000 -0.015000 0.105543 1.000000 $ 18-Dec-2018 18:10:39.177 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.810000 116.621941 31.450000 172.500000 $ 18-Dec-2018 18:10:38.975 Ascend Vel PID Values 0.100000 0.020000 0.019901 0.029934 756768436018649590000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -26095463310987919000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:38.975 Ascend SBE41 Message 15.79, 21.5626, 37.9505 15.790000 15.933434 0.121589 0.020000 0.005000 0.106161 1.000000 $ 18-Dec-2018 18:10:39.973 Ascend Vel PID Values 0.100000 -0.010000 -0.009901 -0.029801 -21946284644540838000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 756768436018649590000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:39.973 Ascend SBE41 Message 15.80, 21.5630, 37.9504 15.800000 15.828790 0.134510 -0.010000 0.005000 0.106353 1.000000 $ 18-Dec-2018 18:10:40.526 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.800000 116.606608 31.450000 172.500000 $ 18-Dec-2018 18:10:40.639 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0130024 $ 18-Dec-2018 18:10:40.742 Ascend MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:10:41.047 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.800000 116.624206 31.450000 172.500000 $ 18-Dec-2018 18:10:40.963 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009867 636442254691684300000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -21946284644540838000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:40.963 Ascend SBE41 Message 15.80, 21.5626, 37.9507 15.800000 15.797924 0.138220 0.000000 -0.005000 0.105865 1.000000 $ 18-Dec-2018 18:10:41.996 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000033 -18456825386058847000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 636442254691684300000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:41.996 Ascend SBE41 Message 15.80, 21.5629, 37.9512 15.800000 15.795785 0.136929 0.000000 0.000000 0.104755 1.000000 $ 18-Dec-2018 18:10:42.551 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.800000 116.622001 31.450000 172.500000 $ 18-Dec-2018 18:10:42.663 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0178468 $ 18-Dec-2018 18:10:42.766 Ascend MSC: OUT: SL $ 18-Dec-2018 18:10:43.070 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.800000 116.601974 31.450000 172.500000 $ 18-Dec-2018 18:10:42.961 Ascend Vel PID Values 0.100000 0.260000 0.259135 0.259135 535247936195706540000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -18456825386058847000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:42.961 Ascend SBE41 Message 15.54, 21.5639, 37.9505 15.540000 15.798131 0.129152 0.260000 0.130000 0.103441 1.000000 $ 18-Dec-2018 18:10:44.016 Ascend MSC: RX: 0x8EC9,A,02/06/2012 00:36:09,0,-1.00,-1.0000,-1.0000,297,196,1,79,21.53,54.92,11.572,5.294e-01,10810.00,2257.00,1129.97,13.93,-20.39,-191.68,3.401e-02,17,87,4A9B492546CB444441A13FCD3E783DFD3E663FCF41F4451F49434E8754795B416235693B6FDB756F798E7B9B7C4C7B20789474ED708F6C4C685A650A629260A95FEF6002611462DE657968E56D1171D077177D078317890C8EE393FB985F9B259CBB9C9C9AAF976492898CD486237F93790472B86CF767B162DD5ED65B44586855FE540B5284514B50AE5044503D,6787.8 $ 18-Dec-2018 18:10:44.029 Ascend MSC: Data: 0x8EC9,A,02/06/2012 00:36:09,0,-1.00,-1.0000,-1.0000,297,196,1,79,21.53,54.92,11.572,5.294e-01,10810.00,2257.00,1129.97,13.93,-20.39,-191.68,3.401e-02,17,87,4A9B492546CB444441A13FCD3E783DFD3E663FCF41F4451F49434E8754795B416235693B6FDB756F798E7B9B7C4C7B20789474ED708F6C4C685A650A629260A95FEF6002611462DE657968E56D1171D077177D078317890C8EE393FB985F9B259CBB9C9C9AAF976492898CD486237F93790472B86CF767B162DD5ED65B44586855FE540B5284514B50AE5044503D,6787.8 $ 18-Dec-2018 18:10:44.237 Ascend MSC post: -191.68 $ 18-Dec-2018 18:10:44.016 Ascend Vel PID Values 0.100000 0.530000 0.529100 0.269965 -15522190149675489000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 535247936195706540000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:44.016 Ascend SBE41 Message 15.01, 21.5638, 37.9512 15.010000 15.798044 0.109712 0.530000 0.395000 0.102363 1.000000 $ 18-Dec-2018 18:10:44.891 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 15.010000 116.530597 31.450000 172.500000 $ 18-Dec-2018 18:10:45.003 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3354270 $ 18-Dec-2018 18:10:45.106 Ascend MSC: Done Sampling. $ 18-Dec-2018 18:10:45.208 Ascend MSC: OUT: SLP $ 18-Dec-2018 18:10:45.001 Ascend Vel PID Values 0.100000 0.340000 0.340631 -0.188469 450143514340589220000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -15522190149675489000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:45.001 Ascend SBE41 Message 14.67, 21.5642, 37.9511 14.670000 15.789119 0.078930 0.340000 0.435000 0.101714 1.000000 $ 18-Dec-2018 18:10:45.864 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.670000 116.309062 31.450000 172.500000 $ 18-Dec-2018 18:10:46.009 Ascend MSC: RX: ACK,SLP $ 18-Dec-2018 18:10:45.975 Ascend Vel PID Values 0.100000 0.020000 0.021066 -0.319565 -13054161915877087000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 450143514340589220000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:45.975 Ascend SBE41 Message 14.65, 21.5641, 37.9513 14.650000 15.745787 0.049295 0.020000 0.180000 0.101363 1.000000 $ 18-Dec-2018 18:10:46.663 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.650000 116.295397 31.450000 172.500000 $ 18-Dec-2018 18:10:46.956 Ascend Vel PID Values 0.100000 -0.010000 -0.009899 -0.030965 378570695560435530000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -13054161915877087000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:46.956 Ascend SBE41 Message 14.66, 21.5643, 37.9514 14.660000 15.622317 0.038461 -0.010000 0.005000 0.101216 1.000000 $ 18-Dec-2018 18:10:47.560 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.660000 116.271451 31.450000 172.500000 $ 18-Dec-2018 18:10:47.955 Ascend Vel PID Values 0.100000 -0.010000 -0.010000 -0.000101 -10978550171252632000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 378570695560435530000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:47.955 Ascend SBE41 Message 14.67, 21.5648, 37.9506 14.670000 15.395238 0.053603 -0.010000 -0.010000 0.101347 1.000000 $ 18-Dec-2018 18:10:48.560 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.670000 116.285756 31.450000 172.500000 $ 18-Dec-2018 18:10:48.955 Ascend Vel PID Values 0.100000 0.020000 0.019901 0.029901 318377954966326320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -10978550171252632000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:48.955 Ascend SBE41 Message 14.65, 21.5649, 37.9513 14.650000 15.111875 0.084836 0.020000 0.005000 0.101822 1.000000 $ 18-Dec-2018 18:10:49.561 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.650000 116.279975 31.450000 172.500000 $ 18-Dec-2018 18:10:49.954 Ascend Vel PID Values 0.100000 -0.020000 -0.019868 -0.039768 -9232960694023463900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 318377954966326320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:49.954 Ascend SBE41 Message 14.67, 21.5652, 37.9514 14.670000 14.868110 0.114737 -0.020000 0.000000 0.102420 1.000000 $ 18-Dec-2018 18:10:50.564 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.670000 116.291672 31.450000 172.500000 $ 18-Dec-2018 18:10:50.953 Ascend Vel PID Values 0.100000 0.000000 -0.000066 0.019801 267755860126680430000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -9232960694023463900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:50.953 Ascend SBE41 Message 14.67, 21.5656, 37.9510 14.670000 14.725853 0.132647 0.000000 -0.010000 0.102725 1.000000 $ 18-Dec-2018 18:10:51.567 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.670000 116.263628 31.450000 172.500000 $ 18-Dec-2018 18:10:51.952 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000066 -7764919943673732200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 267755860126680430000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:51.952 Ascend SBE41 Message 14.67, 21.5657, 37.9511 14.670000 14.672787 0.139220 0.000000 0.000000 0.102490 1.000000 $ 18-Dec-2018 18:10:52.560 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.670000 116.257906 31.450000 172.500000 $ 18-Dec-2018 18:10:52.950 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.009967 225182678366538240000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -7764919943673732200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:52.950 Ascend SBE41 Message 14.66, 21.5661, 37.9510 14.660000 14.662222 0.139424 0.010000 0.005000 0.101743 1.000000 $ 18-Dec-2018 18:10:53.562 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.660000 116.246372 31.450000 172.500000 $ 18-Dec-2018 18:10:53.951 Ascend Vel PID Values 0.100000 0.290000 0.289068 0.279101 -6530297672629608100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 225182678366538240000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:53.951 Ascend SBE41 Message 14.37, 21.5664, 37.9511 14.370000 14.662735 0.133984 0.290000 0.150000 0.100891 1.000000 $ 18-Dec-2018 18:10:54.560 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 14.370000 116.255552 31.450000 172.500000 $ 18-Dec-2018 18:10:54.949 Ascend Vel PID Values 0.100000 0.520000 0.519233 0.230164 189378632506258640000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -6530297672629608100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:54.949 Ascend SBE41 Message 13.85, 21.5666, 37.9513 13.850000 14.664044 0.118525 0.520000 0.405000 0.100316 1.000000 $ 18-Dec-2018 18:10:55.561 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 19 Pres, BP, BatV, BatI: 13.850000 116.263121 31.450000 172.500000 $ 18-Dec-2018 18:10:56.011 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:10:56.015 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:10:56.617 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:10:56.634 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:10:56.735 Ascend Sending FLBB run command $ 18-Dec-2018 18:10:56.838 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:10:56.944 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:10:57.144 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:10:57.259 Ascend CTD post: 13.54 21.567 37.95 $ 18-Dec-2018 18:10:55.947 Ascend Vel PID Values 0.100000 0.310000 0.310698 -0.208535 -5491980342681500600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 189378632506258640000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:55.947 Ascend SBE41 Message 13.54, 21.5668, 37.9516 13.540000 14.655871 0.091432 0.310000 0.415000 0.100117 1.000000 $ 18-Dec-2018 18:10:57.042 Ascend Vel PID Values 0.100000 0.010000 0.011000 -0.299698 159267429937763520000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -5491980342681500600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:57.042 Ascend SBE41 Message 13.53, 21.5670, 37.9516 13.530000 14.608669 0.062216 0.010000 0.160000 0.100095 1.000000 $ 18-Dec-2018 18:10:58.049 Ascend Radiometer Message SATFI40287,-0.0052,0.0008,-0.0076,-0.1785 $ 18-Dec-2018 18:10:58.167 Ascend Radiometer post: SATFI40287,-0.0052,0.0008,-0.0076,-0.1785 $ 18-Dec-2018 18:10:57.716 Ascend Optode Message 4330,1532,270.422,21.675,29.253,29.185,36.274,7.089,528.1,464.7,137.1 $ 18-Dec-2018 18:10:58.384 Ascend Optode post: 4330,1532,270.422,21.675,29.253,29.185,36.274,7.089,528.1,464.7,137.1 $ 18-Dec-2018 18:10:57.717 Ascend Optode Message # $ 18-Dec-2018 18:10:58.805 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.530000 116.253227 31.450000 172.500000 $ 18-Dec-2018 18:10:58.916 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9080607 $ 18-Dec-2018 18:10:58.922 Ascend Starting ISUS sample $ 18-Dec-2018 18:10:59.123 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156657, 13.53, 21.567, 37.95 $ 18-Dec-2018 18:10:59.226 Ascend MSC: OUT: W $ 18-Dec-2018 18:10:59.484 Ascend MSC: OUT: W $ 18-Dec-2018 18:10:58.048 Ascend Vel PID Values 0.100000 0.009999 0.010001 -0.000999 -4618755468195141900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 159267429937763520000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:10:58.048 Ascend SBE41 Message 13.52, 21.5681, 37.9509 13.520000 14.477656 0.048270 0.009999 0.010000 0.100208 1.000000 $ 18-Dec-2018 18:10:59.936 Ascend FLBB Message /99/99,99:99:99,695,2316,700,4130,535 $ 18-Dec-2018 18:11:00.046 Ascend FLBB post: /99/99,99:99:99,695,2316,700,4130,535 $ 18-Dec-2018 18:10:59.020 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009968 133943908577659110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -4618755468195141900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:10:59.020 Ascend SBE41 Message 13.52, 21.5677, 37.9514 13.520000 14.245441 0.059397 0.000000 0.005000 0.100589 1.000000 $ 18-Dec-2018 18:11:00.498 Ascend MSC: RX: $ 18-Dec-2018 18:11:00.600 Ascend MSC: RX: $ 18-Dec-2018 18:11:00.704 Ascend MSC: RX: ACK $ 18-Dec-2018 18:11:00.708 Ascend MSC: Got ACK $ 18-Dec-2018 18:11:00.184 Ascend Vel PID Values 0.100000 0.000000 0.000000 -0.000033 -3884373348752114600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 133943908577659110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:00.184 Ascend SBE41 Message 13.52, 21.5677, 37.9511 13.520000 13.964257 0.087617 0.000000 0.000000 0.101236 1.000000 $ 18-Dec-2018 18:11:01.361 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.520000 117.060348 31.450000 172.500000 $ 18-Dec-2018 18:11:01.472 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.5502367 $ 18-Dec-2018 18:11:00.942 Ascend Vel PID Values 0.100000 0.000000 0.000000 -0.000000 112646827113811320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3884373348752114600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:00.942 Ascend SBE41 Message 13.52, 21.5677, 37.9518 13.520000 13.727479 0.115613 0.000000 0.000000 0.102067 1.000000 $ 18-Dec-2018 18:11:02.129 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.520000 117.543921 31.450000 172.500000 $ 18-Dec-2018 18:11:02.482 Ascend MSC: OUT: CTD,1545156661,21.5677,37.9518,13.5200 $ 18-Dec-2018 18:11:01.941 Ascend Vel PID Values 0.100000 0.000000 -0.000000 -0.000000 -3266757986300528100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 112646827113811320000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:01.941 Ascend SBE41 Message 13.52, 21.5682, 37.9517 13.520000 13.589872 0.132721 0.000000 0.000000 0.102590 1.000000 $ 18-Dec-2018 18:11:02.950 Ascend Vel PID Values 0.100000 -0.009999 -0.009966 -0.009966 94735981602715315000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3266757986300528100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:02.950 Ascend SBE41 Message 13.53, 21.5685, 37.9514 13.530000 13.536182 0.139542 -0.009999 -0.005000 0.102539 1.000000 $ 18-Dec-2018 18:11:03.204 Ascend MSC: RX: ACK,CTD,1545156661,21.5677,37.9518,13.52 $ 18-Dec-2018 18:11:03.607 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.530000 117.529511 31.450000 172.500000 $ 18-Dec-2018 18:11:03.718 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2388204 $ 18-Dec-2018 18:11:04.024 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.530000 117.897093 31.450000 172.500000 $ 18-Dec-2018 18:11:04.724 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:04.979 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:03.940 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009933 -2747343466478744200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 94735981602715315000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:03.940 Ascend SBE41 Message 13.53, 21.5686, 37.9517 13.530000 13.522650 0.140205 0.000000 -0.005000 0.101976 1.000000 $ 18-Dec-2018 18:11:04.938 Ascend Vel PID Values 0.100000 0.210000 0.209301 0.209334 79672960527883579000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2747343466478744200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:04.938 Ascend SBE41 Message 13.32, 21.5688, 37.9518 13.320000 13.520655 0.134596 0.210000 0.105000 0.101232 1.000000 $ 18-Dec-2018 18:11:05.982 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 13.320000 117.977336 31.450000 172.500000 $ 18-Dec-2018 18:11:06.095 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3717230 $ 18-Dec-2018 18:11:05.937 Ascend Vel PID Values 0.100000 0.509999 0.509000 0.299699 -2310515855308623800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 79672960527883579000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:05.937 Ascend SBE41 Message 12.81, 21.5689, 37.9521 12.810000 13.520781 0.118352 0.509999 0.360000 0.100732 1.000000 $ 18-Dec-2018 18:11:06.750 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.810000 118.656531 31.450000 172.500000 $ 18-Dec-2018 18:11:06.935 Ascend Vel PID Values 0.100000 0.380000 0.380431 -0.128569 67004959803950090000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -2310515855308623800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:06.935 Ascend SBE41 Message 12.43, 21.5694, 37.9521 12.430000 13.515541 0.090261 0.380000 0.445000 0.100580 1.000000 $ 18-Dec-2018 18:11:07.655 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.430000 118.738621 31.450000 172.500000 $ 18-Dec-2018 18:11:08.102 Ascend MSC: Timeout for CommandWake $ 18-Dec-2018 18:11:07.936 Ascend Vel PID Values 0.100000 0.040000 0.041132 -0.339299 -1943143834314552700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 67004959803950090000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:07.936 Ascend SBE41 Message 12.39, 21.5696, 37.9518 12.390000 13.480385 0.059827 0.040000 0.210000 0.100633 1.000000 $ 18-Dec-2018 18:11:08.756 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 118.724093 31.450000 172.500000 $ 18-Dec-2018 18:11:09.103 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:09.455 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:08.934 Ascend Vel PID Values 0.100000 0.000000 0.000135 -0.040997 56351171195122024000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1943143834314552700000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:08.934 Ascend SBE41 Message 12.39, 21.5699, 37.9520 12.390000 13.370641 0.044115 0.000000 0.020000 0.100768 1.000000 $ 18-Dec-2018 18:11:09.808 Ascend MSC: RX: ACK $ 18-Dec-2018 18:11:09.910 Ascend MSC: Got ACK $ 18-Dec-2018 18:11:10.111 Ascend MSC: RX: ACK $ 18-Dec-2018 18:11:10.115 Ascend MSC: Got ACK $ 18-Dec-2018 18:11:10.009 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.009832 -1634183964658538800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 56351171195122024000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:10.009 Ascend SBE41 Message 12.38, 21.5706, 37.9517 12.380000 13.157980 0.053397 0.010000 0.005000 0.101105 1.000000 $ 18-Dec-2018 18:11:10.866 Ascend PTH Message 765.062012 22.325000 52.933258 23.313589 $ 18-Dec-2018 18:11:11.069 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.380000 118.891507 29.975000 176.000000 $ 18-Dec-2018 18:11:11.181 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.0782299 $ 18-Dec-2018 18:11:11.286 Ascend MSC: OUT: MODE,1 $ 18-Dec-2018 18:11:10.960 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019901 47391334975097629000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1634183964658538800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:10.960 Ascend SBE41 Message 12.39, 21.5715, 37.9511 12.390000 12.880211 0.081114 -0.010000 0.000000 0.101786 1.000000 $ 18-Dec-2018 18:11:11.942 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 118.899196 29.975000 176.000000 $ 18-Dec-2018 18:11:12.189 Ascend MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:11:11.931 Ascend Vel PID Values 0.100000 -0.009999 -0.009999 -0.000065 -1374348714277831200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 47391334975097629000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:11.931 Ascend SBE41 Message 12.40, 21.5709, 37.9519 12.400000 12.629073 0.110516 -0.009999 -0.010000 0.102599 1.000000 $ 18-Dec-2018 18:11:12.845 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.400000 118.890390 29.975000 176.000000 $ 18-Dec-2018 18:11:12.956 Ascend Vel PID Values 0.100000 0.009999 0.009933 0.019932 39856112714057105000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1374348714277831200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:12.956 Ascend SBE41 Message 12.39, 21.5711, 37.9521 12.390000 12.472348 0.129678 0.009999 0.000000 0.103192 1.000000 $ 18-Dec-2018 18:11:13.741 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 118.863165 29.975000 176.000000 $ 18-Dec-2018 18:11:14.189 Ascend MSC: OUT: ACK $ 18-Dec-2018 18:11:13.928 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009900 -1155827268707656100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 39856112714057105000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:13.928 Ascend SBE41 Message 12.39, 21.5709, 37.9524 12.390000 12.406939 0.137805 0.000000 0.005000 0.103247 1.000000 $ 18-Dec-2018 18:11:14.845 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 118.898377 29.975000 176.000000 $ 18-Dec-2018 18:11:14.956 Ascend Vel PID Values 0.100000 0.000000 0.000000 -0.000033 33518990792522028000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -1155827268707656100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:14.956 Ascend SBE41 Message 12.39, 21.5718, 37.9518 12.390000 12.390649 0.139177 0.000000 0.000000 0.102753 1.000000 $ 18-Dec-2018 18:11:15.744 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.390000 118.895605 29.975000 176.000000 $ 18-Dec-2018 18:11:16.190 Ascend MSC: OUT: TS $ 18-Dec-2018 18:11:15.928 Ascend Vel PID Values 0.100000 0.050000 0.049834 0.049834 -972050732983138820000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 33518990792522028000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:15.928 Ascend SBE41 Message 12.34, 21.5719, 37.9519 12.340000 12.390124 0.134879 0.050000 0.025000 0.102015 1.000000 $ 18-Dec-2018 18:11:16.843 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 12.340000 118.901342 29.975000 176.000000 $ 18-Dec-2018 18:11:17.190 Ascend MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:11:16.955 Ascend Vel PID Values 0.100000 0.460000 0.458635 0.408802 28189471256511024000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -972050732983138820000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:16.955 Ascend SBE41 Message 11.88, 21.5723, 37.9519 11.880000 12.391577 0.121101 0.460000 0.255000 0.101475 1.000000 $ 18-Dec-2018 18:11:17.844 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 20 Pres, BP, BatV, BatI: 11.880000 119.071543 29.975000 176.000000 $ 18-Dec-2018 18:11:18.192 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:11:18.200 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:11:18.899 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:11:18.916 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:11:19.116 Ascend Sending FLBB run command $ 18-Dec-2018 18:11:19.120 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:11:19.225 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:11:19.424 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:11:19.539 Ascend CTD post: 11.37 21.572 37.95 $ 18-Dec-2018 18:11:17.955 Ascend Vel PID Values 0.100000 0.510000 0.509832 0.051196 -817494666438819800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 28189471256511024000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:17.955 Ascend SBE41 Message 11.37, 21.5723, 37.9524 11.370000 12.389008 0.095096 0.510000 0.485000 0.101278 1.000000 $ 18-Dec-2018 18:11:19.014 Ascend Vel PID Values 0.100000 0.150000 0.151197 -0.358634 23707345326725775000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -817494666438819800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:19.014 Ascend SBE41 Message 11.22, 21.5726, 37.9522 11.220000 12.368294 0.063296 0.150000 0.330000 0.101237 1.000000 $ 18-Dec-2018 18:11:20.334 Ascend Radiometer Message SATFI40287,-0.0054,-0.0001,-0.0078,-0.1778 $ 18-Dec-2018 18:11:20.449 Ascend Radiometer post: SATFI40287,-0.0054,-0.0001,-0.0078,-0.1778 $ 18-Dec-2018 18:11:19.981 Ascend Vel PID Values 0.100000 0.000000 0.000501 -0.150696 -687513014475047430000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 23707345326725775000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:19.981 Ascend SBE41 Message 11.22, 21.5728, 37.9524 11.220000 12.292423 0.041619 0.000000 0.075000 0.101222 1.000000 $ 18-Dec-2018 18:11:20.001 Ascend Optode Message 4330,1532,270.316,21.683,29.254,29.186,36.277,7.091,528.1,464.6,136.8 $ 18-Dec-2018 18:11:21.018 Ascend Optode post: 4330,1532,270.316,21.683,29.254,29.186,36.277,7.091,528.1,464.6,136.8 $ 18-Dec-2018 18:11:20.001 Ascend Optode Message # $ 18-Dec-2018 18:11:21.437 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.220000 119.110331 29.975000 176.000000 $ 18-Dec-2018 18:11:21.548 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.3588616 $ 18-Dec-2018 18:11:21.652 Ascend FLBB Message /99/99,99:99:99,695,2313,700,4130,534 $ 18-Dec-2018 18:11:21.762 Ascend FLBB post: /99/99,99:99:99,695,2313,700,4130,534 $ 18-Dec-2018 18:11:21.017 Ascend Vel PID Values 0.100000 0.000000 0.000001 -0.000500 19937877419776376000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -687513014475047430000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:21.017 Ascend SBE41 Message 11.22, 21.5729, 37.9526 11.220000 12.117349 0.043888 0.000000 0.000000 0.101293 1.000000 $ 18-Dec-2018 18:11:22.420 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.220000 119.910777 29.975000 176.000000 $ 18-Dec-2018 18:11:21.921 Ascend Vel PID Values 0.100000 0.000000 0.000000 -0.000001 -578198445173514840000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 19937877419776376000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:21.921 Ascend SBE41 Message 11.22, 21.5729, 37.9514 11.220000 11.848192 0.069087 0.000000 0.000000 0.101692 1.000000 $ 18-Dec-2018 18:11:23.108 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.220000 119.881630 29.975000 176.000000 $ 18-Dec-2018 18:11:22.920 Ascend Vel PID Values 0.100000 -0.009999 -0.009966 -0.009966 16767754910031929000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -578198445173514840000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:22.920 Ascend SBE41 Message 11.23, 21.5735, 37.9522 11.230000 11.564665 0.102149 -0.009999 -0.005000 0.102390 1.000000 $ 18-Dec-2018 18:11:23.907 Ascend MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:11:24.009 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009933 -486264892390925890000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 16767754910031929000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:24.009 Ascend SBE41 Message 11.23, 21.5733, 37.9529 11.230000 11.358933 0.127551 0.000000 -0.005000 0.102995 1.000000 $ 18-Dec-2018 18:11:24.565 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.230000 119.877487 29.975000 176.000000 $ 18-Dec-2018 18:11:24.677 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1223442 $ 18-Dec-2018 18:11:24.982 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.230000 119.882390 29.975000 176.000000 $ 18-Dec-2018 18:11:25.682 Ascend MSC: OUT: SL $ 18-Dec-2018 18:11:24.917 Ascend Vel PID Values 0.100000 0.009999 0.009966 0.009999 14101681879336851000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -486264892390925890000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:24.917 Ascend SBE41 Message 11.22, 21.5746, 37.9519 11.220000 11.258277 0.140206 0.009999 0.005000 0.103206 1.000000 $ 18-Dec-2018 18:11:25.922 Ascend Vel PID Values 0.100000 -0.020000 -0.019900 -0.029866 -408948774500768680000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 14101681879336851000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:25.922 Ascend SBE41 Message 11.24, 21.5744, 37.9521 11.240000 11.227543 0.143702 -0.020000 -0.005000 0.102853 1.000000 $ 18-Dec-2018 18:11:26.594 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.240000 119.882524 29.975000 176.000000 $ 18-Dec-2018 18:11:26.707 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0251825 $ 18-Dec-2018 18:11:26.811 Ascend MSC: RX: 0x33DB,A,02/06/2012 00:36:52,0,-1.00,-1.0000,-1.0000,298,196,1,80,21.58,54.99,11.572,5.294e-01,10818.00,2260.00,1132.14,12.57,-2069016FB0755879597B827C347AFD786774B170786C38682764DC625660885FB95FEC60ED62A4653E68B66CE271A576E07CDB82F288EA8EB593E3981D9AF79C879C709A85971F924A8CA886147F6B78D372766CBC67A262B35EBA5B4A584 $ 18-Dec-2018 18:11:26.827 Ascend MSC: Data: 0x33DB,A,02/06/2012 00:36:52,0,-1.00,-1.0000,-1.0000,298,196,1,80,21.58,54.99,11.572,5.294e-01,10818.00,2260.00,1132.14,12.57,-2069016FB0755879597B827C347AFD786774B170786C38682764DC625660885FB95FEC60ED62A4653E68B66CE271A576E07CDB82F288EA8EB593E3981D9AF79C879C709A85971F924A8CA886147F6B78D372766CBC67A262B35EBA5B4A584 $ 18-Dec-2018 18:11:26.925 Ascend Vel PID Values 0.100000 0.010000 0.009901 0.029800 11859514460522291000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -408948774500768680000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:26.925 Ascend SBE41 Message 11.23, 21.5741, 37.9527 11.230000 11.223800 0.141596 0.010000 -0.005000 0.102145 1.000000 $ 18-Dec-2018 18:11:27.591 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.230000 119.820505 29.975000 176.000000 $ 18-Dec-2018 18:11:27.810 Ascend MSC: Done Sampling. $ 18-Dec-2018 18:11:27.814 Ascend Starting pH sample $ 18-Dec-2018 18:11:27.917 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:28.269 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:28.014 Ascend Vel PID Values 0.100000 0.169999 0.169467 0.159566 -343925919355146460000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 11859514460522291000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:28.014 Ascend SBE41 Message 11.06, 21.5750, 37.9521 11.060000 11.225612 0.131964 0.169999 0.090000 0.101445 1.000000 $ 18-Dec-2018 18:11:28.725 Ascend MSC: RX: ACK $ 18-Dec-2018 18:11:28.729 Ascend MSC: Got ACK $ 18-Dec-2018 18:11:29.131 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 11.060000 119.713619 29.975000 176.000000 $ 18-Dec-2018 18:11:29.243 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4326274 $ 18-Dec-2018 18:11:29.346 Ascend MSC: OUT: MODE,2 $ 18-Dec-2018 18:11:29.452 Ascend MSC: RX: ACK $ 18-Dec-2018 18:11:29.456 Ascend MSC: Got ACK $ 18-Dec-2018 18:11:28.946 Ascend Vel PID Values 0.100000 0.560000 0.558702 0.389235 9973851661299247300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -343925919355146460000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:28.946 Ascend SBE41 Message 10.50, 21.5751, 37.9526 10.500000 11.226958 0.110120 0.560000 0.365000 0.101077 1.000000 $ 18-Dec-2018 18:11:30.030 Ascend MSC: RX: ACK,MODE,2 $ 18-Dec-2018 18:11:29.916 Ascend Vel PID Values 0.100000 0.420000 0.420464 -0.138238 -289241698177678160000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 9973851661299247300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:29.916 Ascend SBE41 Message 10.08, 21.5753, 37.9528 10.080000 11.222144 0.077413 0.420000 0.490000 0.100947 1.000000 $ 18-Dec-2018 18:11:30.687 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.080000 119.698122 29.975000 176.000000 $ 18-Dec-2018 18:11:30.799 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4534306 $ 18-Dec-2018 18:11:31.105 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.080000 119.692281 29.975000 176.000000 $ 18-Dec-2018 18:11:31.804 Ascend MSC: OUT: ACK $ 18-Dec-2018 18:11:30.910 Ascend Vel PID Values 0.100000 0.030000 0.031298 -0.389165 8388009247152666400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -289241698177678160000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:30.910 Ascend SBE41 Message 10.05, 21.5757, 37.9525 10.050000 11.188387 0.046520 0.030000 0.225000 0.100807 1.000000 $ 18-Dec-2018 18:11:31.909 Ascend Vel PID Values 0.100000 0.010000 0.010069 -0.021229 -243252268167427360000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 8388009247152666400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:31.909 Ascend SBE41 Message 10.04, 21.5755, 37.9530 10.040000 11.079445 0.034550 0.010000 0.020000 0.100605 1.000000 $ 18-Dec-2018 18:11:32.814 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.040000 119.700000 29.975000 176.000000 $ 18-Dec-2018 18:11:32.928 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1247811 $ 18-Dec-2018 18:11:32.927 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.010036 7054315776855393500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -243252268167427360000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:32.927 Ascend SBE41 Message 10.04, 21.5763, 37.9524 10.040000 10.861444 0.049062 0.000000 0.005000 0.100559 1.000000 $ 18-Dec-2018 18:11:33.585 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.040000 119.468004 29.975000 176.000000 $ 18-Dec-2018 18:11:33.935 Ascend MSC: OUT: TS $ 18-Dec-2018 18:11:33.908 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.010000 -204575157528806420000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 7054315776855393500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:33.908 Ascend SBE41 Message 10.05, 21.5767, 37.9519 10.050000 10.569667 0.081349 -0.010000 -0.005000 0.100871 1.000000 $ 18-Dec-2018 18:11:34.591 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.050000 119.304344 29.975000 176.000000 $ 18-Dec-2018 18:11:34.935 Ascend MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:11:34.907 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019901 5932679568335387000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -204575157528806420000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:34.907 Ascend SBE41 Message 10.04, 21.5762, 37.9529 10.040000 10.301689 0.114044 0.010000 0.000000 0.101391 1.000000 $ 18-Dec-2018 18:11:35.592 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.040000 119.294167 29.975000 176.000000 $ 18-Dec-2018 18:11:35.905 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009901 -172047707481726220000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 5932679568335387000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:35.905 Ascend SBE41 Message 10.04, 21.5763, 37.9520 10.040000 10.133435 0.135104 0.000000 0.005000 0.101738 1.000000 $ 18-Dec-2018 18:11:36.488 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.040000 119.292319 29.975000 176.000000 $ 18-Dec-2018 18:11:36.904 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.010000 4989383516970061100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -172047707481726220000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:36.904 Ascend SBE41 Message 10.05, 21.5762, 37.9534 10.050000 10.063556 0.143936 -0.010000 -0.005000 0.101640 1.000000 $ 18-Dec-2018 18:11:37.487 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.050000 119.304359 29.975000 176.000000 $ 18-Dec-2018 18:11:37.904 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019901 -144692121992131790000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 4989383516970061100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:37.904 Ascend SBE41 Message 10.04, 21.5771, 37.9528 10.040000 10.045817 0.145541 0.010000 0.000000 0.101253 1.000000 $ 18-Dec-2018 18:11:38.488 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 10.040000 119.300470 29.975000 176.000000 $ 18-Dec-2018 18:11:38.903 Ascend Vel PID Values 0.100000 0.230000 0.229267 0.219334 4196071537771821300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -144692121992131790000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:38.903 Ascend SBE41 Message 9.81, 21.5776, 37.9526 9.810000 10.043487 0.141639 0.230000 0.120000 0.100943 1.000000 $ 18-Dec-2018 18:11:39.489 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 21 Pres, BP, BatV, BatI: 9.810000 119.300216 29.975000 176.000000 $ 18-Dec-2018 18:11:39.938 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:11:39.942 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:11:40.641 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:11:40.659 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:11:40.858 Ascend Sending FLBB run command $ 18-Dec-2018 18:11:40.862 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:11:40.968 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:11:41.168 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:11:41.283 Ascend CTD post: 9.29 21.578 37.95 $ 18-Dec-2018 18:11:39.901 Ascend Vel PID Values 0.100000 0.520000 0.519034 0.289767 -121686074595382820000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 4196071537771821300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:39.901 Ascend SBE41 Message 9.29, 21.5778, 37.9527 9.290000 10.042628 0.128245 0.520000 0.375000 0.100863 1.000000 $ 18-Dec-2018 18:11:40.964 Ascend Vel PID Values 0.100000 0.390000 0.390431 -0.128603 3528896163266102100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -121686074595382820000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:40.964 Ascend SBE41 Message 8.90, 21.5776, 37.9535 8.900000 10.034577 0.102256 0.390000 0.455000 0.101053 1.000000 $ 18-Dec-2018 18:11:41.982 Ascend Radiometer Message SATFI40287,-0.0047,0.0003,-0.0072,-0.1758 $ 18-Dec-2018 18:11:42.196 Ascend Radiometer post: SATFI40287,-0.0047,0.0003,-0.0072,-0.1758 $ 18-Dec-2018 18:11:41.744 Ascend Optode Message 4330,1532,270.275,21.687,29.254,29.186,36.277,7.091,528.0,464.4,136.7 $ 18-Dec-2018 18:11:42.415 Ascend Optode post: 4330,1532,270.275,21.687,29.254,29.186,36.277,7.091,528.0,464.4,136.7 $ 18-Dec-2018 18:11:41.744 Ascend Optode Message # $ 18-Dec-2018 18:11:42.832 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.900000 119.298175 29.975000 176.000000 $ 18-Dec-2018 18:11:42.948 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0134661 $ 18-Dec-2018 18:11:41.965 Ascend Vel PID Values 0.100000 0.030000 0.031198 -0.359233 -102337988734716970000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 3528896163266102100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:41.965 Ascend SBE41 Message 8.87, 21.5779, 37.9535 8.870000 9.993965 0.071182 0.030000 0.210000 0.101229 1.000000 $ 18-Dec-2018 18:11:43.306 Ascend FLBB Message /99/99,99:99:99,695,2321,700,4130,534 $ 18-Dec-2018 18:11:43.516 Ascend FLBB post: /99/99,99:99:99,695,2321,700,4130,534 $ 18-Dec-2018 18:11:42.946 Ascend Vel PID Values 0.100000 0.010000 0.010069 -0.021130 2967801673306792100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -102337988734716970000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:42.946 Ascend SBE41 Message 8.86, 21.5782, 37.9534 8.860000 9.875408 0.052701 0.010000 0.020000 0.101375 1.000000 $ 18-Dec-2018 18:11:43.971 Ascend MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:11:44.275 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.860000 119.999096 29.975000 176.000000 $ 18-Dec-2018 18:11:44.388 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4341366 $ 18-Dec-2018 18:11:43.970 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.020002 -86066248525896980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 2967801673306792100000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:43.970 Ascend SBE41 Message 8.87, 21.5791, 37.9528 8.870000 9.651862 0.059540 -0.010000 0.000000 0.101699 1.000000 $ 18-Dec-2018 18:11:45.045 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.870000 120.188653 29.975000 176.000000 $ 18-Dec-2018 18:11:45.394 Ascend MSC: OUT: SL $ 18-Dec-2018 18:11:44.898 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009900 2495921207251012300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -86066248525896980000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:44.898 Ascend SBE41 Message 8.87, 21.5788, 37.9532 8.870000 9.364414 0.086454 0.000000 -0.005000 0.102385 1.000000 $ 18-Dec-2018 18:11:46.051 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.870000 120.272756 29.975000 176.000000 $ 18-Dec-2018 18:11:46.395 Ascend MSC: RX: 0x4A53,pH,02/06/2012 00:37:14,0,-1.00,-1.0000,-1.0000,315,196,0,21.61,54.94,11.744,4.640e-02,7.1234,0.000,-1.027928,0.001799,-1. $ 18-Dec-2018 18:11:46.500 Ascend MSC: Data: 0x4A53,pH,02/06/2012 00:37:14,0,-1.00,-1.0000,-1.0000,315,196,0,21.61,54.94,11.744,4.640e-02,7.1234,0.000,-1.027928,0.001799,-1. $ 18-Dec-2018 18:11:46.604 Ascend MSC post: 7.1234 $ 18-Dec-2018 18:11:45.921 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000033 -72381715010279366000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 2495921207251012300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:45.921 Ascend SBE41 Message 8.87, 21.5794, 37.9528 8.870000 9.107517 0.116049 0.000000 0.000000 0.103221 1.000000 $ 18-Dec-2018 18:11:46.942 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009967 2099069735298101500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -72381715010279366000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:46.942 Ascend SBE41 Message 8.88, 21.5795, 37.9531 8.880000 8.949323 0.135352 -0.010000 -0.005000 0.103822 1.000000 $ 18-Dec-2018 18:11:47.611 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.880000 120.287165 29.975000 176.000000 $ 18-Dec-2018 18:11:47.723 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3293598 $ 18-Dec-2018 18:11:47.729 Ascend MSC: Done Sampling. $ 18-Dec-2018 18:11:47.830 Ascend MSC: OUT: SLP $ 18-Dec-2018 18:11:47.929 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009934 -60873022323644945000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 2099069735298101500000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:47.929 Ascend SBE41 Message 8.88, 21.5796, 37.9525 8.880000 8.885063 0.143215 0.000000 -0.005000 0.103939 1.000000 $ 18-Dec-2018 18:11:48.585 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.880000 120.514005 29.975000 176.000000 $ 18-Dec-2018 18:11:48.730 Ascend MSC: RX: ACK,SLP $ 18-Dec-2018 18:11:48.936 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.880000 120.715231 29.975000 176.000000 $ 18-Dec-2018 18:11:48.893 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000033 1765317647385703400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -60873022323644945000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:48.893 Ascend SBE41 Message 8.88, 21.5795, 37.9533 8.880000 8.870192 0.144063 0.000000 0.000000 0.103683 1.000000 $ 18-Dec-2018 18:11:49.968 Ascend Vel PID Values 0.100000 0.020000 0.019934 0.019934 -51194211774185395000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1765317647385703400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:49.968 Ascend SBE41 Message 8.86, 21.5804, 37.9528 8.860000 8.870406 0.138997 0.020000 0.010000 0.103344 1.000000 $ 18-Dec-2018 18:11:50.640 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.860000 120.718926 29.975000 176.000000 $ 18-Dec-2018 18:11:50.751 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0215855 $ 18-Dec-2018 18:11:51.059 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 8.860000 120.732367 29.975000 176.000000 $ 18-Dec-2018 18:11:50.891 Ascend Vel PID Values 0.100000 0.380000 0.378802 0.358868 1484632141451376200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -51194211774185395000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:50.891 Ascend SBE41 Message 8.48, 21.5801, 37.9537 8.480000 8.873253 0.123956 0.380000 0.200000 0.103306 1.000000 $ 18-Dec-2018 18:11:51.896 Ascend Vel PID Values 0.100000 0.530000 0.529499 0.150697 -43054332102089912000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1484632141451376200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:51.896 Ascend SBE41 Message 7.95, 21.5809, 37.9534 7.950000 8.874614 0.096119 0.530000 0.455000 0.103487 1.000000 $ 18-Dec-2018 18:11:52.666 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 22 Pres, BP, BatV, BatI: 7.950000 120.718241 29.975000 176.000000 $ 18-Dec-2018 18:11:52.777 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0186948 $ 18-Dec-2018 18:11:52.885 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:11:52.889 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:11:53.588 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:11:53.605 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:11:53.707 Ascend Sending FLBB run command $ 18-Dec-2018 18:11:53.808 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:11:54.011 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:11:54.016 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:11:54.230 Ascend CTD post: 7.68 21.580 37.95 $ 18-Dec-2018 18:11:52.987 Ascend Vel PID Values 0.100000 0.270000 0.270864 -0.258634 1248575630960607400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -43054332102089912000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:52.987 Ascend SBE41 Message 7.68, 21.5805, 37.9538 7.680000 8.862446 0.062065 0.270000 0.400000 0.103560 1.000000 $ 18-Dec-2018 18:11:53.910 Ascend Vel PID Values 0.100000 0.010000 0.010866 -0.259998 -36208693297857616000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1248575630960607400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:53.910 Ascend SBE41 Message 7.67, 21.5815, 37.9530 7.670000 8.802698 0.037683 0.010000 0.140000 0.103472 1.000000 $ 18-Dec-2018 18:11:55.054 Ascend Radiometer Message SATFI40287,-0.0041,0.0010,-0.0072,-0.1831 $ 18-Dec-2018 18:11:55.168 Ascend Radiometer post: SATFI40287,-0.0041,0.0010,-0.0072,-0.1831 $ 18-Dec-2018 18:11:54.682 Ascend Optode Message 4330,1532,270.319,21.692,29.250,29.182,36.273,7.091,528.0,464.1,136.6 $ 18-Dec-2018 18:11:55.385 Ascend Optode post: 4330,1532,270.319,21.692,29.250,29.182,36.273,7.091,528.0,464.1,136.6 $ 18-Dec-2018 18:11:54.700 Ascend Optode Message # $ 18-Dec-2018 18:11:55.804 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.670000 120.579347 29.975000 176.000000 $ 18-Dec-2018 18:11:55.916 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1319873 $ 18-Dec-2018 18:11:55.922 Ascend Starting ISUS sample $ 18-Dec-2018 18:11:56.122 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156714, 7.67, 21.581, 37.95 $ 18-Dec-2018 18:11:56.226 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:56.481 Ascend MSC: OUT: W $ 18-Dec-2018 18:11:54.936 Ascend Vel PID Values 0.100000 -0.010000 -0.009932 -0.020798 1050052105637870900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -36208693297857616000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:54.936 Ascend SBE41 Message 7.68, 21.5811, 37.9533 7.680000 8.648756 0.037157 -0.010000 0.000000 0.103310 1.000000 $ 18-Dec-2018 18:11:56.937 Ascend FLBB Message /99/99,99:99:99,695,2308,700,4130,534 $ 18-Dec-2018 18:11:57.049 Ascend FLBB post: /99/99,99:99:99,695,2308,700,4130,534 $ 18-Dec-2018 18:11:55.914 Ascend Vel PID Values 0.100000 0.010000 0.009933 0.019865 -30451511063498258000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 1050052105637870900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:55.914 Ascend SBE41 Message 7.67, 21.5812, 37.9540 7.670000 8.391199 0.061062 0.010000 0.000000 0.103411 1.000000 $ 18-Dec-2018 18:11:57.405 Ascend MSC: RX: $ 18-Dec-2018 18:11:57.604 Ascend MSC: RX: $ 18-Dec-2018 18:11:56.936 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009900 883093820841449460000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -30451511063498258000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:56.936 Ascend SBE41 Message 7.67, 21.5818, 37.9537 7.670000 8.095589 0.095790 0.000000 0.005000 0.103818 1.000000 $ 18-Dec-2018 18:11:57.966 Ascend MSC: RX: ACK $ 18-Dec-2018 18:11:58.067 Ascend MSC: Got ACK $ 18-Dec-2018 18:11:58.468 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.670000 119.939417 29.975000 176.000000 $ 18-Dec-2018 18:11:58.586 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.6642249 $ 18-Dec-2018 18:11:57.949 Ascend Vel PID Values 0.100000 -0.010000 -0.009966 -0.010000 -25609720804402032000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 883093820841449460000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:57.949 Ascend SBE41 Message 7.68, 21.5818, 37.9540 7.680000 7.859747 0.125006 -0.010000 -0.005000 0.104288 1.000000 $ 18-Dec-2018 18:11:59.246 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.680000 119.609281 29.975000 176.000000 $ 18-Dec-2018 18:11:59.593 Ascend MSC: OUT: CTD,1545156718,21.5818,37.9540,7.6800 $ 18-Dec-2018 18:11:58.929 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009933 742681903327658950000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -25609720804402032000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:11:58.929 Ascend SBE41 Message 7.68, 21.5825, 37.9535 7.680000 7.730772 0.141336 0.000000 -0.005000 0.104444 1.000000 $ 18-Dec-2018 18:11:59.950 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009934 -21537775196502108000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 742681903327658950000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:11:59.950 Ascend SBE41 Message 7.69, 21.5823, 37.9537 7.690000 7.684480 0.147248 -0.010000 -0.005000 0.104195 1.000000 $ 18-Dec-2018 18:12:00.319 Ascend MSC: RX: ACK,CTD,1545156718,21.5818,37.9540,7.68 $ 18-Dec-2018 18:12:00.722 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.690000 119.631335 29.975000 176.000000 $ 18-Dec-2018 18:12:00.833 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2415589 $ 18-Dec-2018 18:12:00.937 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009934 624595480698561200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -21537775196502108000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:00.937 Ascend SBE41 Message 7.69, 21.5824, 37.9541 7.690000 7.674749 0.146944 0.000000 -0.005000 0.103781 1.000000 $ 18-Dec-2018 18:12:01.493 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.690000 119.622380 29.975000 176.000000 $ 18-Dec-2018 18:12:01.840 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:02.193 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:01.942 Ascend Vel PID Values 0.100000 0.060000 0.059800 0.059833 -18113268940258276000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 624595480698561200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:01.942 Ascend SBE41 Message 7.63, 21.5834, 37.9534 7.630000 7.675013 0.139500 0.060000 0.030000 0.103599 1.000000 $ 18-Dec-2018 18:12:02.850 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.630000 119.612217 29.975000 176.000000 $ 18-Dec-2018 18:12:02.962 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1219425 $ 18-Dec-2018 18:12:02.960 Ascend Vel PID Values 0.100000 0.430000 0.428769 0.368968 525284799267489940000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -18113268940258276000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:02.960 Ascend SBE41 Message 7.20, 21.5834, 37.9534 7.200000 7.677879 0.120080 0.430000 0.245000 0.103707 1.000000 $ 18-Dec-2018 18:12:03.623 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 7.200000 119.595915 29.975000 176.000000 $ 18-Dec-2018 18:12:03.877 Ascend Vel PID Values 0.100000 0.510000 0.509731 0.080963 -15233259178757208000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 525284799267489940000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:03.877 Ascend SBE41 Message 6.69, 21.5837, 37.9539 6.690000 7.679096 0.088058 0.510000 0.470000 0.103870 1.000000 $ 18-Dec-2018 18:12:04.524 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.690000 119.564757 29.975000 176.000000 $ 18-Dec-2018 18:12:04.969 Ascend MSC: Timeout for CommandWake $ 18-Dec-2018 18:12:04.877 Ascend Vel PID Values 0.100000 0.220000 0.220965 -0.288767 441764516183959020000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -15233259178757208000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:04.877 Ascend SBE41 Message 6.47, 21.5838, 37.9509 6.470000 7.662895 0.053498 0.220000 0.365000 0.103826 1.000000 $ 18-Dec-2018 18:12:05.626 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.470000 119.599774 29.975000 176.000000 $ 18-Dec-2018 18:12:05.968 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:06.322 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:05.875 Ascend Vel PID Values 0.100000 0.000000 0.000734 -0.220231 -12811170969334812000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 441764516183959020000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:05.875 Ascend SBE41 Message 6.47, 21.5838, 37.9544 6.470000 7.591067 0.033214 0.000000 0.110000 0.103487 1.000000 $ 18-Dec-2018 18:12:06.776 Ascend MSC: RX: ACK $ 18-Dec-2018 18:12:06.780 Ascend MSC: Got ACK $ 18-Dec-2018 18:12:06.981 Ascend MSC: RX: ACK $ 18-Dec-2018 18:12:06.986 Ascend MSC: Got ACK $ 18-Dec-2018 18:12:06.878 Ascend Vel PID Values 0.100000 0.000000 0.000001 -0.000733 371523958110709510000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -12811170969334812000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:06.878 Ascend SBE41 Message 6.47, 21.5841, 37.9542 6.470000 7.419224 0.038515 0.000000 0.000000 0.103105 1.000000 $ 18-Dec-2018 18:12:07.740 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.470000 119.595319 29.975000 176.000000 $ 18-Dec-2018 18:12:07.853 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.8854729 $ 18-Dec-2018 18:12:07.958 Ascend MSC: OUT: MODE,1 $ 18-Dec-2018 18:12:07.957 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009968 -10774194785210576000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 371523958110709510000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:07.957 Ascend SBE41 Message 6.48, 21.5848, 37.9536 6.480000 7.149078 0.066200 -0.010000 -0.005000 0.102922 1.000000 $ 18-Dec-2018 18:12:08.618 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.480000 119.598135 29.975000 176.000000 $ 18-Dec-2018 18:12:08.860 Ascend MSC: RX: ACK,MODE,1 $ 18-Dec-2018 18:12:08.962 Ascend Vel PID Values 0.100000 0.020000 0.019900 0.029867 312451648771106710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -10774194785210576000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:08.962 Ascend SBE41 Message 6.46, 21.5840, 37.9540 6.460000 6.855667 0.101294 0.020000 0.005000 0.103068 1.000000 $ 18-Dec-2018 18:12:09.517 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.460000 119.593456 29.975000 176.000000 $ 18-Dec-2018 18:12:10.062 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.460000 119.608149 29.975000 176.000000 $ 18-Dec-2018 18:12:10.860 Ascend MSC: OUT: ACK $ 18-Dec-2018 18:12:09.871 Ascend Vel PID Values 0.100000 -0.010000 -0.009900 -0.029800 -9061097814362093600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 312451648771106710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:09.871 Ascend SBE41 Message 6.47, 21.5849, 37.9541 6.470000 6.633446 0.128833 -0.010000 0.005000 0.103268 1.000000 $ 18-Dec-2018 18:12:10.963 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009867 262771836616500710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -9061097814362093600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:10.963 Ascend SBE41 Message 6.47, 21.5844, 37.9545 6.470000 6.518333 0.143451 0.000000 -0.005000 0.103129 1.000000 $ 18-Dec-2018 18:12:11.874 Ascend PTH Message 768.248291 22.325000 53.017181 23.324314 $ 18-Dec-2018 18:12:12.078 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.470000 119.592264 29.475000 267.000000 $ 18-Dec-2018 18:12:12.189 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3295636 $ 18-Dec-2018 18:12:11.870 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009934 -7620383261878520800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 262771836616500710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:11.870 Ascend SBE41 Message 6.48, 21.5859, 37.9534 6.480000 6.479519 0.148417 -0.010000 -0.005000 0.102706 1.000000 $ 18-Dec-2018 18:12:12.853 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.480000 120.251104 29.475000 267.000000 $ 18-Dec-2018 18:12:13.196 Ascend MSC: OUT: TS $ 18-Dec-2018 18:12:12.962 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019901 220991114594477110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -7620383261878520800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:12.962 Ascend SBE41 Message 6.47, 21.5854, 37.9544 6.470000 6.471273 0.147427 0.010000 0.000000 0.102251 1.000000 $ 18-Dec-2018 18:12:13.855 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.470000 120.497227 29.475000 267.000000 $ 18-Dec-2018 18:12:14.197 Ascend MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:12:13.965 Ascend Vel PID Values 0.100000 0.020000 0.019967 0.010033 -6408742323239836400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 220991114594477110000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:13.965 Ascend SBE41 Message 6.45, 21.5859, 37.9538 6.450000 6.469701 0.138715 0.020000 0.015000 0.102106 1.000000 $ 18-Dec-2018 18:12:14.854 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.450000 120.504469 29.475000 267.000000 $ 18-Dec-2018 18:12:14.964 Ascend Vel PID Values 0.100000 0.410000 0.408702 0.388735 185853527373955260000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -6408742323239836400000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:14.964 Ascend SBE41 Message 6.04, 21.5864, 37.9535 6.040000 6.469856 0.117417 0.410000 0.215000 0.102224 1.000000 $ 18-Dec-2018 18:12:15.752 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 6.040000 120.516196 29.475000 267.000000 $ 18-Dec-2018 18:12:15.864 Ascend Vel PID Values 0.100000 0.520000 0.519632 0.110930 -5389752293844702900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 185853527373955260000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:15.864 Ascend SBE41 Message 5.52, 21.5864, 37.9542 5.520000 6.469584 0.084024 0.520000 0.465000 0.102313 1.000000 $ 18-Dec-2018 18:12:16.752 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 23 Pres, BP, BatV, BatI: 5.520000 120.519012 29.475000 267.000000 $ 18-Dec-2018 18:12:17.199 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:12:17.203 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:12:17.805 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:12:17.824 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:12:17.926 Ascend Sending FLBB run command $ 18-Dec-2018 18:12:18.028 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:12:18.230 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:12:18.235 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:12:18.447 Ascend CTD post: 5.27 21.586 37.95 $ 18-Dec-2018 18:12:16.864 Ascend Vel PID Values 0.100000 0.250000 0.250898 -0.268734 156302816521496370000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -5389752293844702900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:16.864 Ascend SBE41 Message 5.27, 21.5863, 37.9546 5.270000 6.455472 0.049479 0.250000 0.385000 0.102036 1.000000 $ 18-Dec-2018 18:12:17.922 Ascend Vel PID Values 0.100000 0.000000 0.000833 -0.250064 -4532781679123394800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 156302816521496370000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:17.922 Ascend SBE41 Message 5.27, 21.5867, 37.9544 5.270000 6.391426 0.029919 0.000000 0.125000 0.101358 1.000000 $ 18-Dec-2018 18:12:19.150 Ascend Radiometer Message SATFI40287,-0.0050,0.0013,-0.0071,-0.1732 $ 18-Dec-2018 18:12:19.367 Ascend Radiometer post: SATFI40287,-0.0050,0.0013,-0.0071,-0.1732 $ 18-Dec-2018 18:12:18.895 Ascend Vel PID Values 0.100000 0.010000 0.009968 0.009134 131450668694578450000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -4532781679123394800000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:18.895 Ascend SBE41 Message 5.26, 21.5870, 37.9543 5.260000 6.231091 0.035511 0.010000 0.005000 0.100601 1.000000 $ 18-Dec-2018 18:12:18.896 Ascend Optode Message 4330,1532,270.295,21.706,29.246,29.177,36.271,7.094,527.9,464.2,136.1 $ 18-Dec-2018 18:12:19.938 Ascend Optode post: 4330,1532,270.295,21.706,29.246,29.177,36.271,7.094,527.9,464.2,136.1 $ 18-Dec-2018 18:12:18.914 Ascend Optode Message # $ 18-Dec-2018 18:12:20.258 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.260000 120.649457 29.475000 267.000000 $ 18-Dec-2018 18:12:20.373 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1763994 $ 18-Dec-2018 18:12:20.476 Ascend FLBB Message /99/99,99:99:99,695,2309,700,4130,534 $ 18-Dec-2018 18:12:20.587 Ascend FLBB post: /99/99,99:99:99,695,2309,700,4130,534 $ 18-Dec-2018 18:12:19.936 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009935 -3812069392142774900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 131450668694578450000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:19.936 Ascend SBE41 Message 5.26, 21.5873, 37.9545 5.260000 5.968893 0.063136 0.000000 0.005000 0.100075 1.000000 $ 18-Dec-2018 18:12:21.045 Ascend MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:12:21.349 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.260000 120.677188 29.475000 267.000000 $ 18-Dec-2018 18:12:20.930 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.009934 110550012372140470000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3812069392142774900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:20.930 Ascend SBE41 Message 5.25, 21.5874, 37.9542 5.250000 5.674149 0.098576 0.010000 0.005000 0.099876 1.000000 $ 18-Dec-2018 18:12:22.033 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.250000 120.693222 29.475000 267.000000 $ 18-Dec-2018 18:12:22.476 Ascend MSC: OUT: SL $ 18-Dec-2018 18:12:21.860 Ascend Vel PID Values 0.100000 -0.010000 -0.009934 -0.019901 -3205950358792073900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 110550012372140470000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:21.860 Ascend SBE41 Message 5.26, 21.5873, 37.9548 5.260000 5.443220 0.126964 -0.010000 0.000000 0.099881 1.000000 $ 18-Dec-2018 18:12:23.135 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.260000 120.647505 29.475000 267.000000 $ 18-Dec-2018 18:12:23.477 Ascend MSC: RX: 0x63EF,A,02/06/2012 00:37:49,0,-1.00,-1.0000,-1.0000,299,196,1,81,21.68,54.93,11.572,5.292e-01,10837.00,2247.00,1128.37,14.26,-20.39,-191.58,3.402e-02,17,87,4A6548F146AC43FF41763F9C3E563DD53E4A3FB841D344F6490CC8719276DF7CE382CD88C48E8793B697F19ADE9C679C569A73972D92558C8D85E57F5478C2726A6CB8679E62D55EB15B23584C55DE53FF5271514F5081503E5033,6767.8 $ 18-Dec-2018 18:12:23.586 Ascend MSC: Data: 0x63EF,A,02/06/2012 00:37:49,0,-1.00,-1.0000,-1.0000,299,196,1,81,21.68,54.93,11.572,5.292e-01,10837.00,2247.00,1128.37,14.26,-20.39,-191.58,3.402e-02,17,87,4A6548F146AC43FF41763F9C3E563DD53E4A3FB841D344F6490CC8719276DF7CE382CD88C48E8793B697F19ADE9C679C569A73972D92558C8D85E57F5478C2726A6CB8679E62D55EB15B23584C55DE53FF5271514F5081503E5033,6767.8 $ 18-Dec-2018 18:12:23.696 Ascend MSC post: -191.58 $ 18-Dec-2018 18:12:23.103 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009901 92972560404970151000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -3205950358792073900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:23.103 Ascend SBE41 Message 5.26, 21.5874, 37.9529 5.260000 5.318059 0.142490 0.000000 -0.005000 0.099874 1.000000 $ 18-Dec-2018 18:12:23.858 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000033 -2696204251744134600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000 92972560404970151000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:23.858 Ascend SBE41 Message 5.26, 21.5880, 37.9542 5.260000 5.271864 0.148186 0.000000 0.000000 0.100113 1.000000 $ 18-Dec-2018 18:12:24.707 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.260000 120.678663 29.475000 267.000000 $ 18-Dec-2018 18:12:24.820 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3435044 $ 18-Dec-2018 18:12:24.924 Ascend MSC: Done Sampling. $ 18-Dec-2018 18:12:24.928 Ascend Starting pH sample $ 18-Dec-2018 18:12:25.127 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:25.382 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:24.923 Ascend Vel PID Values 0.100000 -0.010000 -0.009966 -0.009966 78189923300579907000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000 -2696204251744134600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:24.923 Ascend SBE41 Message 5.27, 21.5881, 37.9541 5.270000 5.259913 0.147915 -0.010000 -0.005000 0.100683 1.000000 $ 18-Dec-2018 18:12:25.741 Ascend MSC: RX: ACK $ 18-Dec-2018 18:12:25.843 Ascend MSC: Got ACK $ 18-Dec-2018 18:12:26.245 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 5.270000 120.665342 29.475000 267.000000 $ 18-Dec-2018 18:12:26.358 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4343796 $ 18-Dec-2018 18:12:26.462 Ascend MSC: OUT: MODE,2 $ 18-Dec-2018 18:12:26.566 Ascend MSC: RX: ACK $ 18-Dec-2018 18:12:26.667 Ascend MSC: Got ACK $ 18-Dec-2018 18:12:26.060 Ascend Vel PID Values 0.100000 0.030000 0.029867 0.039834 -2267507775716817600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000. 78189923300579907000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:26.060 Ascend SBE41 Message 5.24, 21.5882, 37.9548 5.240000 5.257543 0.140265 0.030000 0.010000 0.101420 1.000000 $ 18-Dec-2018 18:12:27.126 Ascend MSC: RX: ACK,MODE,2 $ 18-Dec-2018 18:12:26.855 Ascend Vel PID Values 0.100000 0.360000 0.358901 0.329034 65757725495787710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000. -2267507775716817600000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000. -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:26.855 Ascend SBE41 Message 4.88, 21.5886, 37.9548 4.880000 5.258029 0.120349 0.360000 0.195000 0.102112 1.000000 $ 18-Dec-2018 18:12:27.812 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.880000 120.657533 29.475000 267.000000 $ 18-Dec-2018 18:12:27.926 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.5621765 $ 18-Dec-2018 18:12:27.924 Ascend Vel PID Values 0.100000 0.510000 0.509499 0.150598 -19069740393778437000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 65757725495787710000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000. 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:27.924 Ascend SBE41 Message 4.37, 21.5888, 37.9549 4.370000 5.258302 0.087871 0.510000 0.435000 0.102335 1.000000 $ 18-Dec-2018 18:12:28.585 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.370000 120.638266 29.475000 267.000000 $ 18-Dec-2018 18:12:28.932 Ascend MSC: OUT: ACK $ 18-Dec-2018 18:12:28.851 Ascend Vel PID Values 0.100000 0.310000 0.310665 -0.198835 553022471419574690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -19069740393778437000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:28.851 Ascend SBE41 Message 4.06, 21.5891, 37.9548 4.060000 5.246445 0.052882 0.310000 0.410000 0.102025 1.000000 $ 18-Dec-2018 18:12:29.592 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.060000 120.661885 29.475000 267.000000 $ 18-Dec-2018 18:12:29.852 Ascend Vel PID Values 0.100000 0.020000 0.020966 -0.289699 -16037651671167666000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 553022471419574690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:29.852 Ascend SBE41 Message 4.04, 21.5892, 37.9551 4.040000 5.189048 0.031422 0.020000 0.165000 0.101211 1.000000 $ 18-Dec-2018 18:12:30.489 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.040000 120.642647 29.475000 267.000000 $ 18-Dec-2018 18:12:30.933 Ascend MSC: OUT: TS $ 18-Dec-2018 18:12:30.850 Ascend Vel PID Values 0.100000 0.010000 0.010035 -0.010932 465091898463862300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -16037651671167666000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:30.850 Ascend SBE41 Message 4.03, 21.5894, 37.9551 4.030000 5.039689 0.034414 0.010000 0.015000 0.100269 1.000000 $ 18-Dec-2018 18:12:31.592 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.030000 120.667458 29.475000 267.000000 $ 18-Dec-2018 18:12:31.933 Ascend MSC: RX: ACK,TS,CMD $ 18-Dec-2018 18:12:31.849 Ascend Vel PID Values 0.100000 -0.010000 -0.009933 -0.019968 -13487665055452006000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 465091898463862300000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:31.849 Ascend SBE41 Message 4.04, 21.5895, 37.9551 4.040000 4.786374 0.060027 -0.010000 0.000000 0.099524 1.000000 $ 18-Dec-2018 18:12:32.592 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.040000 120.665401 29.475000 267.000000 $ 18-Dec-2018 18:12:32.848 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009900 391142286608108140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -13487665055452006000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:32.848 Ascend SBE41 Message 4.04, 21.5896, 37.9550 4.040000 4.489568 0.095263 0.000000 -0.005000 0.099111 1.000000 $ 18-Dec-2018 18:12:33.490 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.040000 120.646372 29.475000 267.000000 $ 18-Dec-2018 18:12:33.848 Ascend Vel PID Values 0.100000 0.000000 -0.000000 0.000033 -11343126311635138000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 391142286608108140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:33.848 Ascend SBE41 Message 4.04, 21.5905, 37.9548 4.040000 4.245049 0.125231 0.000000 0.000000 0.099023 1.000000 $ 18-Dec-2018 18:12:34.490 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.040000 120.662451 29.475000 267.000000 $ 18-Dec-2018 18:12:34.846 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009967 328950663037419020000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -11343126311635138000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:34.846 Ascend SBE41 Message 4.05, 21.5903, 37.9549 4.050000 4.104748 0.142670 -0.010000 -0.005000 0.099178 1.000000 $ 18-Dec-2018 18:12:35.491 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.050000 120.656759 29.475000 267.000000 $ 18-Dec-2018 18:12:35.846 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019901 -95395692280851517000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 328950663037419020000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:35.846 Ascend SBE41 Message 4.04, 21.5904, 37.9552 4.040000 4.051163 0.149350 0.010000 0.000000 0.099675 1.000000 $ 18-Dec-2018 18:12:36.491 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.040000 120.680079 29.475000 267.000000 $ 18-Dec-2018 18:12:36.844 Ascend Vel PID Values 0.100000 0.010000 0.010000 0.000066 276647507614469390000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -95395692280851517000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:36.844 Ascend SBE41 Message 4.03, 21.5905, 37.9551 4.030000 4.039613 0.149311 0.010000 0.010000 0.100529 1.000000 $ 18-Dec-2018 18:12:37.491 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.030000 120.674670 29.475000 267.000000 $ 18-Dec-2018 18:12:37.844 Ascend Vel PID Values 0.100000 -0.010000 -0.009933 -0.019933 -80227777208196120000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 276647507614469390000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:37.844 Ascend SBE41 Message 4.04, 21.5904, 37.9556 4.040000 4.040035 0.142140 -0.010000 0.000000 0.101523 1.000000 $ 18-Dec-2018 18:12:38.492 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 4.040000 120.655179 29.475000 267.000000 $ 18-Dec-2018 18:12:38.842 Ascend Vel PID Values 0.100000 0.250000 0.249135 0.259068 232660553903768730000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -80227777208196120000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:38.842 Ascend SBE41 Message 3.79, 21.5907, 37.9557 3.790000 4.041651 0.123441 0.250000 0.120000 0.102297 1.000000 $ 18-Dec-2018 18:12:39.492 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 24 Pres, BP, BatV, BatI: 3.790000 120.695919 29.475000 267.000000 $ 18-Dec-2018 18:12:39.938 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:12:39.943 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:12:40.546 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:12:40.562 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:12:40.761 Ascend Sending FLBB run command $ 18-Dec-2018 18:12:40.765 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:12:40.871 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:12:41.071 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:12:41.186 Ascend CTD post: 3.27 21.591 37.96 $ 18-Dec-2018 18:12:39.841 Ascend Vel PID Values 0.100000 0.520000 0.519100 0.269965 -67471560632092929000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 232660553903768730000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:39.841 Ascend SBE41 Message 3.27, 21.5913, 37.9554 3.270000 4.040953 0.092180 0.520000 0.385000 0.102549 1.000000 $ 18-Dec-2018 18:12:40.868 Ascend Vel PID Values 0.100000 0.400000 0.400398 -0.118702 195667525833069490000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -67471560632092929000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:40.868 Ascend SBE41 Message 2.87, 21.5916, 37.9541 2.870000 4.030666 0.056739 0.400000 0.460000 0.102183 1.000000 $ 18-Dec-2018 18:12:41.891 Ascend Radiometer Message SATFI40287,-0.0036,0.0010,-0.0075,-0.1765 $ 18-Dec-2018 18:12:42.106 Ascend Radiometer post: SATFI40287,-0.0036,0.0010,-0.0075,-0.1765 $ 18-Dec-2018 18:12:41.648 Ascend Optode Message 4330,1532,270.186,21.713,29.247,29.179,36.272,7.093,527.8,464.0,135.9 $ 18-Dec-2018 18:12:42.325 Ascend Optode post: 4330,1532,270.186,21.713,29.247,29.179,36.272,7.093,527.8,464.0,135.9 $ 18-Dec-2018 18:12:41.648 Ascend Optode Message # $ 18-Dec-2018 18:12:42.742 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.870000 120.662138 29.475000 267.000000 $ 18-Dec-2018 18:12:42.854 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9195155 $ 18-Dec-2018 18:12:41.871 Ascend Vel PID Values 0.100000 0.060000 0.061132 -0.339266 -56743582491590158000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 195667525833069490000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:41.871 Ascend SBE41 Message 2.81, 21.5919, 37.9554 2.810000 3.986357 0.031981 0.060000 0.230000 0.101288 1.000000 $ 18-Dec-2018 18:12:43.214 Ascend FLBB Message /99/99,99:99:99,695,2320,700,4130,534 $ 18-Dec-2018 18:12:43.422 Ascend FLBB post: /99/99,99:99:99,695,2320,700,4130,534 $ 18-Dec-2018 18:12:43.429 Ascend MSC: RX: ACK,TS,DAT $ 18-Dec-2018 18:12:42.853 Ascend Vel PID Values 0.100000 0.000000 0.000202 -0.060930 164556389225611440000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -56743582491590158000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:42.853 Ascend SBE41 Message 2.81, 21.5923, 37.9553 2.810000 3.863626 0.029808 0.000000 0.030000 0.100139 1.000000 $ 18-Dec-2018 18:12:44.183 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.810000 121.978521 29.475000 267.000000 $ 18-Dec-2018 18:12:44.296 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4342421 $ 18-Dec-2018 18:12:43.866 Ascend Vel PID Values 0.100000 0.000000 0.000000 -0.000201 -47721352875427318000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 164556389225611440000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:43.866 Ascend SBE41 Message 2.81, 21.5928, 37.9549 2.810000 3.634664 0.051496 0.000000 0.000000 0.099130 1.000000 $ 18-Dec-2018 18:12:44.957 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.810000 122.109145 29.475000 267.000000 $ 18-Dec-2018 18:12:45.302 Ascend MSC: OUT: SL $ 18-Dec-2018 18:12:44.835 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.009967 138391923338739230000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -47721352875427318000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:44.835 Ascend SBE41 Message 2.82, 21.5924, 37.9553 2.820000 3.339152 0.086618 -0.010000 -0.005000 0.098516 1.000000 $ 18-Dec-2018 18:12:45.960 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.820000 122.150481 29.475000 267.000000 $ 18-Dec-2018 18:12:46.303 Ascend MSC: RX: 0xE587,pH,02/06/2012 00:38:13,0,-1.00,-1.0000,-1.0000,316,196,0,21.70,54.91,11.744,4.640e-02,7.1234,0.000,-1.017986,0.004784,-1. $ 18-Dec-2018 18:12:46.309 Ascend MSC: Data: 0xE587,pH,02/06/2012 00:38:13,0,-1.00,-1.0000,-1.0000,316,196,0,21.70,54.91,11.744,4.640e-02,7.1234,0.000,-1.017986,0.004784,-1. $ 18-Dec-2018 18:12:46.512 Ascend MSC post: 7.1234 $ 18-Dec-2018 18:12:45.836 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009933 -40133657768234379000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 138391923338739230000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:45.836 Ascend SBE41 Message 2.82, 21.5922, 37.9559 2.820000 3.071982 0.119729 0.000000 -0.005000 0.098343 1.000000 $ 18-Dec-2018 18:12:46.853 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.010000 116387607527879690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -40133657768234379000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:46.853 Ascend SBE41 Message 2.81, 21.5934, 37.9550 2.810000 2.904090 0.140720 0.010000 0.005000 0.098594 1.000000 $ 18-Dec-2018 18:12:47.524 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.810000 122.150913 29.475000 267.000000 $ 18-Dec-2018 18:12:47.635 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3334030 $ 18-Dec-2018 18:12:47.740 Ascend MSC: Done Sampling. $ 18-Dec-2018 18:12:47.842 Ascend MSC: OUT: SLP $ 18-Dec-2018 18:12:47.842 Ascend Vel PID Values 0.100000 -0.010000 -0.009933 -0.019900 -33752406183085111000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 116387607527879690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:47.842 Ascend SBE41 Message 2.82, 21.5929, 37.9554 2.820000 2.833642 0.149368 -0.010000 0.000000 0.099272 1.000000 $ 18-Dec-2018 18:12:48.505 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.820000 122.398078 29.475000 267.000000 $ 18-Dec-2018 18:12:48.643 Ascend MSC: RX: ACK,SLP $ 18-Dec-2018 18:12:48.850 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.820000 122.678578 29.475000 267.000000 $ 18-Dec-2018 18:12:48.831 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009900 978819779309468360000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -33752406183085111000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:48.831 Ascend SBE41 Message 2.82, 21.5934, 37.9555 2.820000 2.816380 0.150236 0.000000 -0.005000 0.100331 1.000000 $ 18-Dec-2018 18:12:49.885 Ascend Vel PID Values 0.100000 0.020000 0.019933 0.019967 -28385773599974582000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 978819779309468360000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:49.885 Ascend SBE41 Message 2.80, 21.5936, 37.9555 2.800000 2.815515 0.144847 0.020000 0.010000 0.101509 1.000000 $ 18-Dec-2018 18:12:50.556 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.800000 122.676775 29.475000 267.000000 $ 18-Dec-2018 18:12:50.667 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0239575 $ 18-Dec-2018 18:12:50.973 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.800000 122.675657 29.475000 267.000000 $ 18-Dec-2018 18:12:50.829 Ascend Vel PID Values 0.100000 0.230000 0.229301 0.209368 823187434399262860000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -28385773599974582000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:50.829 Ascend SBE41 Message 2.57, 21.5939, 37.9555 2.570000 2.816339 0.129539 0.230000 0.125000 0.102388 1.000000 $ 18-Dec-2018 18:12:51.912 Ascend Vel PID Values 0.100000 0.470000 0.469200 0.239899 -23872435597578622000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 823187434399262860000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:51.912 Ascend SBE41 Message 2.10, 21.5940, 37.9558 2.100000 2.815575 0.101294 0.470000 0.350000 0.102729 1.000000 $ 18-Dec-2018 18:12:52.582 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.100000 122.676939 29.475000 267.000000 $ 18-Dec-2018 18:12:52.693 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0202871 $ 18-Dec-2018 18:12:52.999 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 2.100000 122.572571 29.475000 267.000000 $ 18-Dec-2018 18:12:52.827 Ascend Vel PID Values 0.100000 0.390000 0.390265 -0.078935 692300632329780080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -23872435597578622000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:52.827 Ascend SBE41 Message 1.71, 21.5937, 37.9565 1.710000 2.806427 0.065869 0.390000 0.430000 0.102440 1.000000 $ 18-Dec-2018 18:12:53.836 Ascend Vel PID Values 0.100000 0.120000 0.120899 -0.269366 -20076718337563622000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 692300632329780080000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:53.836 Ascend SBE41 Message 1.59, 21.5946, 37.9559 1.590000 2.764169 0.038054 0.120000 0.255000 0.101616 1.000000 $ 18-Dec-2018 18:12:54.607 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 25 Pres, BP, BatV, BatI: 1.590000 122.514799 29.475000 267.000000 $ 18-Dec-2018 18:12:54.718 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.0197022 $ 18-Dec-2018 18:12:54.826 Ascend Sending Optode Do Sample $ 18-Dec-2018 18:12:54.830 Ascend Sending Optode Wakeup $ 18-Dec-2018 18:12:55.432 Ascend Sci Logger sample Optode $ 18-Dec-2018 18:12:55.449 Ascend Sci Logger sample pH and NO3 $ 18-Dec-2018 18:12:55.551 Ascend Sending FLBB run command $ 18-Dec-2018 18:12:55.652 Ascend Sci Logger sample FLBB $ 18-Dec-2018 18:12:55.757 Ascend Sending radiometer pollSample $ 18-Dec-2018 18:12:55.959 Ascend Sci Logger sample Radiometer $ 18-Dec-2018 18:12:56.074 Ascend CTD post: 1.60 21.595 37.96 $ 18-Dec-2018 18:12:54.928 Ascend Vel PID Values 0.100000 -0.010000 -0.009566 -0.130465 582224831789345070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -20076718337563622000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:54.928 Ascend SBE41 Message 1.60, 21.5950, 37.9558 1.600000 2.646717 0.031817 -0.010000 0.055000 0.100487 1.000000 $ 18-Dec-2018 18:12:55.856 Ascend Vel PID Values 0.100000 0.010000 0.009934 0.019500 -16884520121891004000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 582224831789345070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:55.856 Ascend SBE41 Message 1.59, 21.5955, 37.9554 1.590000 2.428777 0.050057 0.010000 0.000000 0.099506 1.000000 $ 18-Dec-2018 18:12:56.780 Ascend Radiometer Message SATFI40287,-0.0039,-0.0008,-0.0075,-0.1812 $ 18-Dec-2018 18:12:56.996 Ascend Radiometer post: SATFI40287,-0.0039,-0.0008,-0.0075,-0.1812 $ 18-Dec-2018 18:12:56.536 Ascend Optode Message 4330,1532,270.096,21.722,29.247,29.179,36.271,7.092,527.8,463.8,135.6 $ 18-Dec-2018 18:12:57.215 Ascend Optode post: 4330,1532,270.096,21.722,29.247,29.179,36.271,7.092,527.8,463.8,135.6 $ 18-Dec-2018 18:12:56.538 Ascend Optode Message # $ 18-Dec-2018 18:12:57.632 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 1.590000 122.229442 29.475000 267.000000 $ 18-Dec-2018 18:12:57.744 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.0190782 $ 18-Dec-2018 18:12:57.750 Ascend Starting ISUS sample $ 18-Dec-2018 18:12:57.951 Ascend Starting MSC Sequence CTDValues (time, press, temp, salinity) 1545156776, 1.59, 21.596, 37.96 $ 18-Dec-2018 18:12:57.957 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:58.407 Ascend MSC: OUT: W $ 18-Dec-2018 18:12:56.879 Ascend Vel PID Values 0.100000 0.000000 0.000033 -0.009901 489651083534839140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -16884520121891004000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:56.879 Ascend SBE41 Message 1.59, 21.5952, 37.9560 1.590000 2.144891 0.083035 0.000000 0.005000 0.098852 1.000000 $ 18-Dec-2018 18:12:58.765 Ascend FLBB Message /99/99,99:99:99,695,2322,700,4130,534 $ 18-Dec-2018 18:12:58.975 Ascend FLBB post: /99/99,99:99:99,695,2322,700,4130,534 $ 18-Dec-2018 18:12:57.848 Ascend Vel PID Values 0.100000 -0.010000 -0.009967 -0.010000 -14199881422510335000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 489651083534839140000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:57.848 Ascend SBE41 Message 1.60, 21.5952, 37.9562 1.600000 1.880387 0.115656 -0.010000 -0.005000 0.098596 1.000000 $ 18-Dec-2018 18:12:59.430 Ascend MSC: RX: $ 18-Dec-2018 18:12:59.435 Ascend MSC: RX: $ 18-Dec-2018 18:12:58.864 Ascend Vel PID Values 0.100000 0.000000 -0.000033 0.009933 411796561252799690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -14199881422510335000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:12:58.864 Ascend SBE41 Message 1.60, 21.5958, 37.9558 1.600000 1.704625 0.137520 0.000000 -0.005000 0.098757 1.000000 $ 18-Dec-2018 18:12:59.989 Ascend MSC: RX: ACK $ 18-Dec-2018 18:12:59.993 Ascend MSC: Got ACK $ 18-Dec-2018 18:13:00.394 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 1.600000 121.409968 29.475000 267.000000 $ 18-Dec-2018 18:13:00.505 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7554440 $ 18-Dec-2018 18:12:59.875 Ascend Vel PID Values 0.100000 0.010000 0.009967 0.010000 -11942100276331191000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 411796561252799690000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:12:59.875 Ascend SBE41 Message 1.59, 21.5961, 37.9553 1.590000 1.623230 0.147514 0.010000 0.005000 0.099358 1.000000 $ 18-Dec-2018 18:13:01.069 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 1.590000 121.010944 29.475000 267.000000 $ 18-Dec-2018 18:13:01.514 Ascend MSC: OUT: CTD,1545156780,21.5961,37.9553,1.5900 $ 18-Dec-2018 18:13:00.850 Ascend Vel PID Values 0.100000 -0.020000 -0.019900 -0.029867 346320908013604520000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -11942100276331191000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:13:00.850 Ascend SBE41 Message 1.61, 21.5964, 37.9557 1.610000 1.598471 0.149451 -0.020000 -0.005000 0.100376 1.000000 $ 18-Dec-2018 18:13:01.872 Ascend Vel PID Values 0.100000 0.040000 0.039800 0.059701 -10043306332394531000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 346320908013604520000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:13:01.872 Ascend SBE41 Message 1.57, 21.5965, 37.9558 1.570000 1.594778 0.144668 0.040000 0.010000 0.101550 1.000000 $ 18-Dec-2018 18:13:02.341 Ascend MSC: RX: ACK,CTD,1545156780,21.5961,37.9553,1.59 $ 18-Dec-2018 18:13:02.647 Ascend RecMode true, PID On, BE Ext'g, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 1.570000 121.011630 29.475000 267.000000 $ 18-Dec-2018 18:13:02.760 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.2476780 $ 18-Dec-2018 18:13:02.863 Ascend Vel PID Values 0.100000 0.260000 0.259268 0.219467 291255883639441410000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -10043306332394531000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 -50.000000 -409600.000000 1.000000 $ 18-Dec-2018 18:13:02.863 Ascend SBE41 Message 1.31, 21.5970, 37.9557 1.310000 1.595804 0.129990 0.260000 0.150000 0.102374 1.000000 $ 18-Dec-2018 18:13:03.418 Ascend RecMode true, PID On, BE Ret'g, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 1.310000 121.004120 29.475000 267.000000 $ 18-Dec-2018 18:13:03.765 Ascend MSC: OUT: W $ 18-Dec-2018 18:13:04.118 Ascend MSC: OUT: W $ 18-Dec-2018 18:13:04.220 Ascend Sending SBE41 stopProfile $ 18-Dec-2018 18:13:03.867 Ascend Vel PID Values 0.100000 0.550000 0.549034 0.289766 -84464206255438002000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 291255883639441410000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 50.000000 409600.000000 1.000000 $ 18-Dec-2018 18:13:03.867 Ascend SBE41 Message 0.76, 21.5971, 37.9560 0.760000 1.595786 0.103016 0.550000 0.405000 0.102778 1.000000 $ 18-Dec-2018 18:13:04.891 Ascend Sending SBE41 stopProfile $ 18-Dec-2018 18:13:05.006 Ascend Powering up GPS $ 18-Dec-2018 18:13:05.108 Ascend Powering up BT Module $ 18-Dec-2018 18:13:05.112 Ascend Normal State Exit $ 18-Dec-2018 18:13:05.316 Ascend Ascend pt: 2018-Dec-18T18:12:54Z 1.60 21.595 37.96 21.722 29.179 7.092 NaN NaN 2322 4130 534 -0.0039 -0.0008 -0.0075 -0.1812 $ 18-Dec-2018 18:13:05.423 Ascend ERROR: Missed PH message 2 $ 18-Dec-2018 18:13:05.428 Ascend ERROR: Missed NO3 message 2 $ 18-Dec-2018 18:13:05.529 Ascend RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 26 Pres, BP, BatV, BatI: 0.760000 120.990261 29.475000 267.000000 $ 18-Dec-2018 18:13:05.738 Ascend ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9735459 $ 18-Dec-2018 18:13:05.841 Init Profile State Entry $ 18-Dec-2018 18:13:05.948 Init Profile Initializing SBE 41 LPF $ 18-Dec-2018 18:13:06.056 Init Profile Sending SBE41 stopProfile $ 18-Dec-2018 18:13:07.061 Init Profile Resetting SBE41 with qsr $ 18-Dec-2018 18:13:07.162 Init Profile Sending qsr command $ 18-Dec-2018 18:13:04.817 Init Profile SBE41 Message 0.41, 21.5968, 37.9560 0.410000 0.759994 0.000001 0.350000 0.175000 -0.000000 1.000000 $ 18-Dec-2018 18:13:05.006 Init Profile Unparsed SBE41 Message profile stopped $ 18-Dec-2018 18:13:09.686 Init Profile Normal State Exit $ 18-Dec-2018 18:13:09.690 Init Profile RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.986477 29.475000 267.000000 $ 18-Dec-2018 18:13:09.903 Init Profile ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:04.0622787 $ 18-Dec-2018 18:13:09.909 Surface Ops Set Bellows State Entry $ 18-Dec-2018 18:13:10.111 Surface Ops Set Bellows Inflating bellows to Surface Ops position = 155.0 at 200000 cps $ 18-Dec-2018 18:13:06.390 Surface Ops Set Bellows Unparsed SBE41 Message S>SBE 41CP UW V 2.0 $ 18-Dec-2018 18:13:07.269 Surface Ops Set Bellows Unparsed SBE41 Message S>qsr $ 18-Dec-2018 18:13:07.270 Surface Ops Set Bellows Unparsed SBE41 Message powering down $ 18-Dec-2018 18:13:09.496 Surface Ops Set Bellows Unparsed SBE41 Message S>SBE 41CP UW V 2.0 $ 18-Dec-2018 18:13:11.294 Surface Ops Set Bellows Normal State Exit $ 18-Dec-2018 18:13:11.299 Surface Ops Set Bellows RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.962307 29.475000 267.000000 $ 18-Dec-2018 18:13:11.512 Surface Ops Set Bellows ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6036188 $ 18-Dec-2018 18:13:11.520 Dump CP Data State Entry $ 18-Dec-2018 18:13:11.718 Dump CP Data Starting valve close $ 18-Dec-2018 18:13:11.828 Dump CP Data Didn't get CR/LF response, trying again $ 18-Dec-2018 18:13:12.133 Dump CP Data PTH Message 769.582520 22.300000 53.123993 23.335039 $ 18-Dec-2018 18:13:12.335 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.980382 31.000000 250.000000 $ 18-Dec-2018 18:13:12.520 Dump CP Data Didn't get CR/LF response, trying again $ 18-Dec-2018 18:13:12.826 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.959878 31.000000 250.000000 $ 18-Dec-2018 18:13:13.520 Dump CP Data Didn't get CR/LF response, trying again $ 18-Dec-2018 18:13:11.827 Dump CP Data CP Message S> $ 18-Dec-2018 18:13:13.932 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.956331 31.000000 250.000000 $ 18-Dec-2018 18:13:14.520 Dump CP Data Got CR/LF response $ 18-Dec-2018 18:13:14.824 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.978221 31.000000 250.000000 $ 18-Dec-2018 18:13:15.519 Dump CP Data Sending binaverage wait command $ 18-Dec-2018 18:13:15.534 Dump CP Data Sending binaverage $ 18-Dec-2018 18:13:15.747 Dump CP Data Trying again for binaverage response $ 18-Dec-2018 18:13:15.746 Dump CP Data CP Message S>binaverage $ 18-Dec-2018 18:13:15.746 Dump CP Data CP Message samples = 253, maxPress = 25.91 $ 18-Dec-2018 18:13:15.850 Dump CP Data CP Message rd: 0 $ 18-Dec-2018 18:13:16.278 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.977566 31.000000 250.000000 $ 18-Dec-2018 18:13:16.520 Dump CP Data Sending binaverage wait command $ 18-Dec-2018 18:13:16.524 Dump CP Data Trying again for binaverage response $ 18-Dec-2018 18:13:16.926 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.970309 31.000000 250.000000 $ 18-Dec-2018 18:13:17.520 Dump CP Data Sending binaverage wait command $ 18-Dec-2018 18:13:17.524 Dump CP Data Trying again for binaverage response $ 18-Dec-2018 18:13:17.212 Dump CP Data CP Message rd: 128 $ 18-Dec-2018 18:13:17.936 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.965853 31.000000 250.000000 $ 18-Dec-2018 18:13:18.521 Dump CP Data Sending binaverage wait command $ 18-Dec-2018 18:13:18.527 Dump CP Data Trying again for binaverage response $ 18-Dec-2018 18:13:18.625 Dump CP Data CP Message avg: 0 $ 18-Dec-2018 18:13:18.727 Dump CP Data CP Message $ 18-Dec-2018 18:13:18.728 Dump CP Data CP Message done, nbins = 14 $ 18-Dec-2018 18:13:19.157 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.992541 31.000000 250.000000 $ 18-Dec-2018 18:13:19.520 Dump CP Data Sending binaverage wait command $ 18-Dec-2018 18:13:19.525 Dump CP Data Got good binaverage response $ 18-Dec-2018 18:13:19.926 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.974556 31.000000 250.000000 $ 18-Dec-2018 18:13:20.521 Dump CP Data Sending da wait command $ 18-Dec-2018 18:13:20.527 Dump CP Data Sending da command $ 18-Dec-2018 18:13:20.628 Dump CP Data Trying again for da response $ 18-Dec-2018 18:13:20.730 Dump CP Data CP Message S>da $ 18-Dec-2018 18:13:20.731 Dump CP Data CP Message 0.59, 21.5970, 37.9560, 2 $ 18-Dec-2018 18:13:20.833 Dump CP Data CP Message 2.18, 21.5941, 37.9556, 23 $ 18-Dec-2018 18:13:20.834 Dump CP Data CP Message 4.05, 21.5899, 37.9551, 14 $ 18-Dec-2018 18:13:20.835 Dump CP Data CP Message 5.89, 21.5860, 37.9540, 23 $ 18-Dec-2018 18:13:20.945 Dump CP Data CP Message 8.22, 21.5806, 37.9534, 23 $ 18-Dec-2018 18:13:20.946 Dump CP Data CP Message 10.00, 21.5763, 37.9526, 12 $ 18-Dec-2018 18:13:20.947 Dump CP Data CP Message 11.83, 21.5721, 37.9521, 23 $ 18-Dec-2018 18:13:21.056 Dump CP Data CP Message 14.06, 21.5665, 37.9513, 21 $ 18-Dec-2018 18:13:21.057 Dump CP Data CP Message 16.25, 21.5613, 37.9504, 22 $ 18-Dec-2018 18:13:21.058 Dump CP Data CP Message 17.98, 21.5567, 37.9498, 13 $ 18-Dec-2018 18:13:21.168 Dump CP Data CP Message 19.85, 21.5516, 37.9490, 22 $ 18-Dec-2018 18:13:21.169 Dump CP Data CP Message 22.26, 21.5446, 37.9482, 25 $ 18-Dec-2018 18:13:21.170 Dump CP Data CP Message 24.45, 21.5368, 37.9459, 21 $ 18-Dec-2018 18:13:21.171 Dump CP Data CP Message 25.72, 21.5342, 37.9310, 9 $ 18-Dec-2018 18:13:21.280 Dump CP Data CP Message upload complete $ 18-Dec-2018 18:13:22.787 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.971814 31.000000 250.000000 $ 18-Dec-2018 18:13:22.899 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.3777421 $ 18-Dec-2018 18:13:22.904 Dump CP Data Sending da wait command $ 18-Dec-2018 18:13:23.103 Dump CP Data Good da response; Upload sucessful $ 18-Dec-2018 18:13:23.407 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.983765 31.000000 250.000000 $ 18-Dec-2018 18:13:23.905 Dump CP Data Sending dah wait command $ 18-Dec-2018 18:13:24.006 Dump CP Data Sending dah command $ 18-Dec-2018 18:13:24.011 Dump CP Data Trying again for dah response $ 18-Dec-2018 18:13:24.113 Dump CP Data CP Message S>dah $ 18-Dec-2018 18:13:24.330 Dump CP Data Appending CP Data: 0006545D944402 $ 18-Dec-2018 18:13:24.114 Dump CP Data CP Message 0006545D944402 $ 18-Dec-2018 18:13:24.545 Dump CP Data Appending CP Data: 0016545A944417 $ 18-Dec-2018 18:13:24.114 Dump CP Data CP Message 0016545A944417 $ 18-Dec-2018 18:13:24.658 Dump CP Data Appending CP Data: 0029545694430E $ 18-Dec-2018 18:13:24.115 Dump CP Data CP Message 0029545694430E $ 18-Dec-2018 18:13:24.967 Dump CP Data Appending CP Data: 003B5452944217 $ 18-Dec-2018 18:13:24.115 Dump CP Data CP Message 003B5452944217 $ 18-Dec-2018 18:13:25.198 Dump CP Data Appending CP Data: 0052544D944117 $ 18-Dec-2018 18:13:24.217 Dump CP Data CP Message 0052544D944117 $ 18-Dec-2018 18:13:25.408 Dump CP Data Appending CP Data: 0064544894410C $ 18-Dec-2018 18:13:24.218 Dump CP Data CP Message 0064544894410C $ 18-Dec-2018 18:13:25.620 Dump CP Data Appending CP Data: 00765444944017 $ 18-Dec-2018 18:13:24.219 Dump CP Data CP Message 00765444944017 $ 18-Dec-2018 18:13:25.831 Dump CP Data Appending CP Data: 008D543F943F15 $ 18-Dec-2018 18:13:24.219 Dump CP Data CP Message 008D543F943F15 $ 18-Dec-2018 18:13:26.041 Dump CP Data Appending CP Data: 00A25439943E16 $ 18-Dec-2018 18:13:24.220 Dump CP Data CP Message 00A25439943E16 $ 18-Dec-2018 18:13:26.253 Dump CP Data Appending CP Data: 00B45435943E0D $ 18-Dec-2018 18:13:24.220 Dump CP Data CP Message 00B45435943E0D $ 18-Dec-2018 18:13:26.463 Dump CP Data Appending CP Data: 00C65430943D16 $ 18-Dec-2018 18:13:24.329 Dump CP Data CP Message 00C65430943D16 $ 18-Dec-2018 18:13:26.674 Dump CP Data Appending CP Data: 00DF5429943C19 $ 18-Dec-2018 18:13:24.435 Dump CP Data CP Message 00DF5429943C19 $ 18-Dec-2018 18:13:26.886 Dump CP Data Appending CP Data: 00F55421943A15 $ 18-Dec-2018 18:13:24.435 Dump CP Data CP Message 00F55421943A15 $ 18-Dec-2018 18:13:27.097 Dump CP Data Appending CP Data: 0101541E942B09 $ 18-Dec-2018 18:13:24.436 Dump CP Data CP Message 0101541E942B09 $ 18-Dec-2018 18:13:27.211 Dump CP Data Writing CP data to msg File $ 18-Dec-2018 18:13:24.436 Dump CP Data CP Message upload complete $ 18-Dec-2018 18:13:27.626 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.986119 31.000000 250.000000 $ 18-Dec-2018 18:13:27.737 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.8324898 $ 18-Dec-2018 18:13:27.743 Dump CP Data Sending dah wait command $ 18-Dec-2018 18:13:27.849 Dump CP Data Good dah response; Upload sucessful $ 18-Dec-2018 18:13:28.152 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.961100 31.000000 250.000000 $ 18-Dec-2018 18:13:29.744 Dump CP Data Calculated new PID Constant, h = 3000 $ 18-Dec-2018 18:13:28.748 Dump CP Data CP Message S> $ 18-Dec-2018 18:13:30.158 Dump CP Data Normal State Exit $ 18-Dec-2018 18:13:30.267 Dump CP Data RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.968148 31.000000 250.000000 $ 18-Dec-2018 18:13:30.379 Dump CP Data ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.6364199 $ 18-Dec-2018 18:13:30.482 Surface Ops State Entry $ 18-Dec-2018 18:13:30.486 Surface Ops Powering up Iridium Modem $ 18-Dec-2018 18:13:42.001 Surface Ops Starting valve close $ 18-Dec-2018 18:13:42.005 Surface Ops IModem waitingForResponse expended all retries $ 18-Dec-2018 18:13:42.408 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.410000 120.991915 31.000000 250.000000 $ 18-Dec-2018 18:13:42.520 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.2974023 $ 18-Dec-2018 18:13:42.525 Surface Ops Sending CREG cmd $ 18-Dec-2018 18:13:30.734 Surface Ops SBE41 Message 3.44 3.440000 0.759283 -0.000008 -1.010000 -0.446667 0.000005 3.000000 $ 18-Dec-2018 18:13:33.603 Surface Ops A3LA Message $ 18-Dec-2018 18:13:42.967 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:33.605 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:43.178 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:33.721 Surface Ops SBE41 Message -0.04 -0.040000 0.757261 -0.000003 1.160000 0.075000 0.000018 3.000000 $ 18-Dec-2018 18:13:34.604 Surface Ops A3LA Message $ 18-Dec-2018 18:13:43.515 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:34.606 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:43.729 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:35.606 Surface Ops A3LA Message $ 18-Dec-2018 18:13:43.940 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:35.608 Surface Ops A3LA Message 0 $ 18-Dec-2018 18:13:44.156 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->0 <-- $ 18-Dec-2018 18:13:44.365 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.040000 120.978206 31.000000 250.000000 $ 18-Dec-2018 18:13:44.477 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.9513953 $ 18-Dec-2018 18:13:35.609 Surface Ops A3LA Message $ 18-Dec-2018 18:13:44.691 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:35.611 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:44.902 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:36.605 Surface Ops A3LA Message $ 18-Dec-2018 18:13:45.116 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:36.613 Surface Ops A3LA Message 300125060561320 $ 18-Dec-2018 18:13:45.330 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->300125060561320 <-- $ 18-Dec-2018 18:13:36.615 Surface Ops A3LA Message $ 18-Dec-2018 18:13:45.543 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:36.617 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:45.756 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:36.721 Surface Ops SBE41 Message -0.05 -0.050000 0.786917 0.000456 0.003333 0.581667 -0.000107 3.000000 $ 18-Dec-2018 18:13:37.607 Surface Ops A3LA Message $ 18-Dec-2018 18:13:46.092 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:37.608 Surface Ops A3LA Message 0 $ 18-Dec-2018 18:13:46.305 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->0 <-- $ 18-Dec-2018 18:13:37.609 Surface Ops A3LA Message $ 18-Dec-2018 18:13:46.516 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:37.611 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:46.730 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:38.606 Surface Ops A3LA Message $ 18-Dec-2018 18:13:46.941 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:38.608 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:47.157 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:47.463 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.050000 120.982513 31.000000 250.000000 $ 18-Dec-2018 18:13:47.575 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.9952924 $ 18-Dec-2018 18:13:39.607 Surface Ops A3LA Message $ 18-Dec-2018 18:13:47.788 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:39.618 Surface Ops A3LA Message 8988169234000597401 $ 18-Dec-2018 18:13:47.999 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->8988169234000597401 <-- $ 18-Dec-2018 18:13:39.619 Surface Ops A3LA Message $ 18-Dec-2018 18:13:48.214 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:39.622 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:48.428 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:39.722 Surface Ops SBE41 Message -0.04 -0.040000 0.933656 0.001090 -0.003333 0.000000 -0.000770 3.000000 $ 18-Dec-2018 18:13:42.731 Surface Ops A3LA Message $ 18-Dec-2018 18:13:48.765 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:42.732 Surface Ops A3LA Message +CREG:000,000 $ 18-Dec-2018 18:13:48.977 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->+CREG:000,000 <-- $ 18-Dec-2018 18:13:42.733 Surface Ops A3LA Message $ 18-Dec-2018 18:13:49.188 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got--> <-- $ 18-Dec-2018 18:13:42.733 Surface Ops A3LA Message OK $ 18-Dec-2018 18:13:49.401 Surface Ops iModem invalid response: Looking for IModem-->+CREG:000,001<-- Got-->OK <-- $ 18-Dec-2018 18:13:44.580 Surface Ops SBE41 Message -4.12 -4.120000 1.160689 -0.003179 1.360000 0.678333 -0.002059 3.000000 $ 18-Dec-2018 18:13:47.574 Surface Ops SBE41 Message -0.06 -0.060000 1.169168 -0.018389 -1.353333 0.003333 -0.003009 3.000000 $ 18-Dec-2018 18:13:49.959 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 120.971113 31.000000 250.000000 $ 18-Dec-2018 18:13:50.074 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4936451 $ 18-Dec-2018 18:13:50.380 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.060000 120.968044 31.000000 250.000000 $ 18-Dec-2018 18:13:50.542 Surface Ops SBE41 Message 1.03 1.030000 0.712982 -0.036232 -0.363333 -0.858333 -0.002408 3.000000 $ 18-Dec-2018 18:13:51.308 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.030000 121.002704 31.000000 250.000000 $ 18-Dec-2018 18:13:52.282 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.030000 120.978221 31.000000 250.000000 $ 18-Dec-2018 18:13:53.283 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.030000 120.980501 31.000000 250.000000 $ 18-Dec-2018 18:13:53.463 Surface Ops SBE41 Message -0.47 -0.470000 -0.089898 -0.032704 0.500000 0.068333 0.000133 3.000000 $ 18-Dec-2018 18:13:54.312 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.470000 120.978743 31.000000 250.000000 $ 18-Dec-2018 18:13:55.284 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.470000 121.003956 31.000000 250.000000 $ 18-Dec-2018 18:13:56.283 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.470000 120.978758 31.000000 250.000000 $ 18-Dec-2018 18:13:56.462 Surface Ops SBE41 Message 1.95 1.950000 -0.856940 0.011838 -0.806667 -0.153333 0.003933 3.000000 $ 18-Dec-2018 18:13:57.310 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.950000 120.991334 31.000000 250.000000 $ 18-Dec-2018 18:13:58.284 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.950000 120.986223 31.000000 250.000000 $ 18-Dec-2018 18:13:59.284 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.950000 120.997444 31.000000 250.000000 $ 18-Dec-2018 18:13:59.460 Surface Ops SBE41 Message -1.48 -1.480000 -1.124477 0.092848 1.143333 0.168333 0.007531 3.000000 $ 18-Dec-2018 18:14:00.313 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.480000 120.980248 31.000000 250.000000 $ 18-Dec-2018 18:14:01.284 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.480000 120.985001 31.000000 250.000000 $ 18-Dec-2018 18:14:02.285 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.480000 120.998979 31.000000 250.000000 $ 18-Dec-2018 18:14:02.462 Surface Ops SBE41 Message -1.62 -1.620000 -0.725405 0.170799 0.046667 0.595000 0.009609 3.000000 $ 18-Dec-2018 18:14:03.409 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.620000 120.993018 31.000000 250.000000 $ 18-Dec-2018 18:14:04.286 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.620000 121.001855 31.000000 250.000000 $ 18-Dec-2018 18:14:05.287 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.620000 120.995000 31.000000 250.000000 $ 18-Dec-2018 18:14:05.462 Surface Ops SBE41 Message 1.29 1.290000 -0.081115 0.187687 -0.970000 -0.461667 0.010064 3.000000 $ 18-Dec-2018 18:14:06.412 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.290000 120.985463 31.000000 250.000000 $ 18-Dec-2018 18:14:07.287 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.290000 121.010751 31.000000 250.000000 $ 18-Dec-2018 18:14:08.287 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 1.290000 121.003687 31.000000 250.000000 $ 18-Dec-2018 18:14:08.462 Surface Ops SBE41 Message 0.31 0.310000 0.243921 0.118358 0.326667 -0.321667 0.009827 3.000000 $ 18-Dec-2018 18:14:09.412 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.310000 121.002495 31.000000 250.000000 $ 18-Dec-2018 18:14:10.289 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.310000 121.008575 31.000000 250.000000 $ 18-Dec-2018 18:14:11.289 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.310000 120.992780 31.000000 250.000000 $ 18-Dec-2018 18:14:11.462 Surface Ops SBE41 Message 0.19 0.190000 0.089061 0.002505 0.040000 0.183333 0.009848 3.000000 $ 18-Dec-2018 18:14:12.319 Surface Ops PTH Message 769.663574 22.308333 53.207916 23.345764 $ 18-Dec-2018 18:14:12.521 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.190000 120.990649 31.350000 155.000000 $ 18-Dec-2018 18:14:13.290 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.190000 121.004328 31.350000 155.000000 $ 18-Dec-2018 18:14:14.291 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.190000 120.998234 31.350000 155.000000 $ 18-Dec-2018 18:14:14.461 Surface Ops SBE41 Message -1.29 -1.290000 -0.240750 -0.085121 0.493333 0.266667 0.010347 3.000000 $ 18-Dec-2018 18:14:15.416 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.290000 120.993420 31.350000 155.000000 $ 18-Dec-2018 18:14:16.292 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.290000 120.980725 31.350000 155.000000 $ 18-Dec-2018 18:14:17.292 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.290000 120.997384 31.350000 155.000000 $ 18-Dec-2018 18:14:17.461 Surface Ops SBE41 Message 0.60 0.600000 -0.291696 -0.096134 -0.630000 -0.068333 0.010814 3.000000 $ 18-Dec-2018 18:14:18.319 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.600000 121.005759 31.350000 155.000000 $ 18-Dec-2018 18:14:19.293 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.600000 120.985284 31.350000 155.000000 $ 18-Dec-2018 18:14:20.294 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.600000 120.994344 31.350000 155.000000 $ 18-Dec-2018 18:14:20.462 Surface Ops SBE41 Message -1.24 -1.240000 -0.035561 -0.045935 0.613333 -0.008333 0.010815 3.000000 $ 18-Dec-2018 18:14:21.419 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.240000 121.001616 31.350000 155.000000 $ 18-Dec-2018 18:14:22.295 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.240000 121.007115 31.350000 155.000000 $ 18-Dec-2018 18:14:23.296 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.240000 121.021688 31.350000 155.000000 $ 18-Dec-2018 18:14:32.132 Surface Ops Trying GPS get position try num: 1 of 6 $ 18-Dec-2018 18:14:33.150 Surface Ops Got Position: lat = 0000.00000 N lon = 00000.00000 E num sats = 0 $ 18-Dec-2018 18:14:23.461 Surface Ops SBE41 Message -0.44 -0.440000 0.108010 0.006662 -0.266667 0.173333 0.010588 3.000000 $ 18-Dec-2018 18:14:33.481 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.440000 121.000215 31.350000 155.000000 $ 18-Dec-2018 18:14:33.598 Surface Ops ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:09.5042932 $ 18-Dec-2018 18:14:33.904 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.440000 121.001959 31.350000 155.000000 $ 18-Dec-2018 18:14:34.066 Surface Ops SBE41 Message 3.66 3.660000 -0.045755 0.020237 -1.366667 -0.816667 0.010424 3.000000 $ 18-Dec-2018 18:14:34.835 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 3.660000 120.991737 31.350000 155.000000 $ 18-Dec-2018 18:14:35.807 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 3.660000 121.002093 31.350000 155.000000 $ 18-Dec-2018 18:14:36.808 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 3.660000 120.994046 31.350000 155.000000 $ 18-Dec-2018 18:14:36.961 Surface Ops SBE41 Message -3.10 -3.100000 -0.267837 0.003632 2.253333 0.443333 0.010552 3.000000 $ 18-Dec-2018 18:14:37.932 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.100000 121.011391 31.350000 155.000000 $ 18-Dec-2018 18:14:38.809 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.100000 121.012270 31.350000 155.000000 $ 18-Dec-2018 18:14:39.810 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.100000 121.013924 31.350000 155.000000 $ 18-Dec-2018 18:14:39.962 Surface Ops SBE41 Message 0.16 0.160000 -0.330830 -0.009598 -1.086667 0.583333 0.010710 3.000000 $ 18-Dec-2018 18:14:40.839 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.160000 121.003807 31.350000 155.000000 $ 18-Dec-2018 18:14:41.810 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.160000 121.024460 31.350000 155.000000 $ 18-Dec-2018 18:14:42.810 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.160000 121.018171 31.350000 155.000000 $ 18-Dec-2018 18:14:42.962 Surface Ops SBE41 Message -2.05 -2.050000 -0.152215 0.000155 0.736667 -0.175000 0.010599 3.000000 $ 18-Dec-2018 18:14:43.935 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.050000 121.009186 31.350000 155.000000 $ 18-Dec-2018 18:14:44.812 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.050000 121.020511 31.350000 155.000000 $ 18-Dec-2018 18:14:45.812 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.050000 121.010050 31.350000 155.000000 $ 18-Dec-2018 18:14:45.960 Surface Ops SBE41 Message -4.25 -4.250000 0.132174 0.019063 0.733333 0.735000 0.010143 3.000000 $ 18-Dec-2018 18:14:46.841 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.250000 120.980278 31.350000 155.000000 $ 18-Dec-2018 18:14:47.813 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.250000 120.996311 31.350000 155.000000 $ 18-Dec-2018 18:14:48.813 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.250000 121.003926 31.350000 155.000000 $ 18-Dec-2018 18:14:48.962 Surface Ops SBE41 Message -3.87 -3.870000 0.110187 0.014702 -0.126667 0.303333 0.009739 3.000000 $ 18-Dec-2018 18:14:49.938 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.870000 121.020660 31.350000 155.000000 $ 18-Dec-2018 18:14:50.814 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.870000 121.008471 31.350000 155.000000 $ 18-Dec-2018 18:14:51.814 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.870000 121.014684 31.350000 155.000000 $ 18-Dec-2018 18:14:51.960 Surface Ops Unparsed SBE41 Message -7.48 $ 18-Dec-2018 18:14:52.833 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.870000 121.029094 31.350000 155.000000 $ 18-Dec-2018 18:14:53.815 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.870000 121.016696 31.350000 155.000000 $ 18-Dec-2018 18:14:54.816 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.870000 120.991588 31.350000 155.000000 $ 18-Dec-2018 18:14:54.960 Surface Ops SBE41 Message -4.47 -4.470000 -0.433621 -0.014239 0.200000 0.036667 0.009906 3.000000 $ 18-Dec-2018 18:14:55.940 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.470000 121.009260 31.350000 155.000000 $ 18-Dec-2018 18:14:56.817 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.470000 121.019185 31.350000 155.000000 $ 18-Dec-2018 18:14:57.817 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.470000 121.012226 31.350000 155.000000 $ 18-Dec-2018 18:14:57.962 Surface Ops SBE41 Message -1.44 -1.440000 -1.292971 -0.026447 -1.010000 -0.405000 0.010941 3.000000 $ 18-Dec-2018 18:14:58.944 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.440000 121.011198 31.350000 155.000000 $ 18-Dec-2018 18:14:59.818 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.440000 121.023804 31.350000 155.000000 $ 18-Dec-2018 18:15:00.818 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.440000 121.013016 31.350000 155.000000 $ 18-Dec-2018 18:15:00.961 Surface Ops SBE41 Message -2.94 -2.940000 -2.257115 0.012353 0.500000 -0.255000 0.012828 3.000000 $ 18-Dec-2018 18:15:01.942 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.940000 121.023908 31.350000 155.000000 $ 18-Dec-2018 18:15:02.819 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.940000 121.006817 31.350000 155.000000 $ 18-Dec-2018 18:15:03.616 Surface Ops Trying GPS get position try num: 2 of 6 $ 18-Dec-2018 18:15:04.030 Surface Ops Got Position: lat = 0000.00000 N lon = 00000.00000 E num sats = 0 $ 18-Dec-2018 18:15:03.960 Surface Ops SBE41 Message -0.07 -0.070000 -3.124418 0.099959 -0.956667 -0.228333 0.015361 3.000000 $ 18-Dec-2018 18:15:04.461 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 121.035740 31.350000 155.000000 $ 18-Dec-2018 18:15:04.817 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 121.014386 31.350000 155.000000 $ 18-Dec-2018 18:15:05.817 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 121.018410 31.350000 155.000000 $ 18-Dec-2018 18:15:06.817 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.070000 121.024445 31.350000 155.000000 $ 18-Dec-2018 18:15:06.960 Surface Ops SBE41 Message -2.60 -2.600000 -3.528580 0.204972 0.843333 -0.056667 0.018022 3.000000 $ 18-Dec-2018 18:15:07.846 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.600000 121.025756 31.350000 155.000000 $ 18-Dec-2018 18:15:08.818 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.600000 121.020034 31.350000 155.000000 $ 18-Dec-2018 18:15:09.818 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.600000 121.015370 31.350000 155.000000 $ 18-Dec-2018 18:15:09.960 Surface Ops SBE41 Message 0.45 0.450000 -3.293408 0.275011 -1.016667 -0.086667 0.020206 3.000000 $ 18-Dec-2018 18:15:10.943 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.450000 120.992556 31.350000 155.000000 $ 18-Dec-2018 18:15:11.819 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.450000 121.015280 31.350000 155.000000 $ 18-Dec-2018 18:15:12.820 Surface Ops PTH Message 769.663574 22.308333 53.345245 23.367214 $ 18-Dec-2018 18:15:13.022 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.450000 121.036425 31.450000 159.000000 $ 18-Dec-2018 18:15:13.021 Surface Ops SBE41 Message -0.18 -0.180000 -2.664512 0.263788 0.210000 -0.403333 0.021611 3.000000 $ 18-Dec-2018 18:15:13.945 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.180000 121.020675 31.450000 159.000000 $ 18-Dec-2018 18:15:14.821 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.180000 121.025905 31.450000 159.000000 $ 18-Dec-2018 18:15:15.821 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.180000 121.034741 31.450000 159.000000 $ 18-Dec-2018 18:15:15.961 Surface Ops SBE41 Message -1.19 -1.190000 -2.011847 0.170224 0.336667 0.273333 0.022299 3.000000 $ 18-Dec-2018 18:15:16.945 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.190000 121.019781 31.450000 159.000000 $ 18-Dec-2018 18:15:17.822 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.190000 121.022329 31.450000 159.000000 $ 18-Dec-2018 18:15:18.822 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.190000 121.019796 31.450000 159.000000 $ 18-Dec-2018 18:15:18.961 Surface Ops SBE41 Message -0.69 -0.690000 -1.495826 0.035619 -0.166667 0.085000 0.022459 3.000000 $ 18-Dec-2018 18:15:19.947 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.690000 121.020555 31.450000 159.000000 $ 18-Dec-2018 18:15:20.823 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.690000 121.021405 31.450000 159.000000 $ 18-Dec-2018 18:15:21.823 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.690000 121.026024 31.450000 159.000000 $ 18-Dec-2018 18:15:21.962 Surface Ops SBE41 Message -4.11 -4.110000 -1.064879 -0.090546 1.140000 0.486667 0.022207 3.000000 $ 18-Dec-2018 18:15:22.850 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.110000 121.019498 31.450000 159.000000 $ 18-Dec-2018 18:15:23.824 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.110000 121.038273 31.450000 159.000000 $ 18-Dec-2018 18:15:24.825 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -4.110000 121.051371 31.450000 159.000000 $ 18-Dec-2018 18:15:24.962 Surface Ops SBE41 Message -1.20 -1.200000 -0.724662 -0.171737 -0.970000 0.085000 0.021648 3.000000 $ 18-Dec-2018 18:15:25.950 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.200000 121.013701 31.450000 159.000000 $ 18-Dec-2018 18:15:26.826 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.200000 121.011347 31.450000 159.000000 $ 18-Dec-2018 18:15:27.826 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.200000 121.019050 31.450000 159.000000 $ 18-Dec-2018 18:15:27.963 Surface Ops SBE41 Message -0.80 -0.800000 -0.664836 -0.195143 -0.133333 -0.551667 0.021045 3.000000 $ 18-Dec-2018 18:15:28.951 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.800000 121.031240 31.450000 159.000000 $ 18-Dec-2018 18:15:29.842 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.800000 121.025980 31.450000 159.000000 $ 18-Dec-2018 18:15:30.828 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.800000 121.027276 31.450000 159.000000 $ 18-Dec-2018 18:15:30.961 Surface Ops SBE41 Message -3.50 -3.500000 -1.010433 -0.171211 0.900000 0.383333 0.020771 3.000000 $ 18-Dec-2018 18:15:31.953 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.500000 121.026248 31.450000 159.000000 $ 18-Dec-2018 18:15:32.828 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.500000 121.035129 31.450000 159.000000 $ 18-Dec-2018 18:15:33.829 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -3.500000 121.021211 31.450000 159.000000 $ 18-Dec-2018 18:15:34.627 Surface Ops Trying GPS get position try num: 3 of 6 $ 18-Dec-2018 18:15:35.040 Surface Ops Got Position: lat = 0000.00000 N lon = 00000.00000 E num sats = 0 $ 18-Dec-2018 18:15:33.961 Surface Ops SBE41 Message -2.09 -2.090000 -1.561081 -0.115023 -0.470000 0.215000 0.021020 3.000000 $ 18-Dec-2018 18:15:35.374 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.090000 121.024847 31.450000 159.000000 $ 18-Dec-2018 18:15:35.829 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.090000 121.032268 31.450000 159.000000 $ 18-Dec-2018 18:15:36.830 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.090000 121.031255 31.450000 159.000000 $ 18-Dec-2018 18:15:36.962 Surface Ops SBE41 Message -1.64 -1.640000 -1.920388 -0.037231 -0.150000 -0.310000 0.021627 3.000000 $ 18-Dec-2018 18:15:37.954 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.640000 121.017694 31.450000 159.000000 $ 18-Dec-2018 18:15:38.831 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.640000 121.045321 31.450000 159.000000 $ 18-Dec-2018 18:15:39.830 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.640000 121.014684 31.450000 159.000000 $ 18-Dec-2018 18:15:39.962 Surface Ops SBE41 Message -2.15 -2.150000 -1.969887 0.043018 0.170000 0.010000 0.022337 3.000000 $ 18-Dec-2018 18:15:40.858 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.150000 121.033609 31.450000 159.000000 $ 18-Dec-2018 18:15:41.831 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.150000 121.027008 31.450000 159.000000 $ 18-Dec-2018 18:15:42.831 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -2.150000 121.029079 31.450000 159.000000 $ 18-Dec-2018 18:15:42.962 Surface Ops SBE41 Message -1.74 -1.740000 -1.991486 0.097035 -0.136667 0.016667 0.022223 3.000000 $ 18-Dec-2018 18:15:43.858 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.740000 121.040329 31.450000 159.000000 $ 18-Dec-2018 18:15:44.832 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.740000 121.036589 31.450000 159.000000 $ 18-Dec-2018 18:15:45.832 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.740000 121.033609 31.450000 159.000000 $ 18-Dec-2018 18:15:45.961 Surface Ops SBE41 Message -0.55 -0.550000 -2.118938 0.109375 -0.396667 -0.266667 0.022109 3.000000 $ 18-Dec-2018 18:15:46.957 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.550000 121.042728 31.450000 159.000000 $ 18-Dec-2018 18:15:47.833 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.550000 121.033922 31.450000 159.000000 $ 18-Dec-2018 18:15:48.833 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.550000 121.031985 31.450000 159.000000 $ 18-Dec-2018 18:15:48.961 Surface Ops SBE41 Message -1.76 -1.760000 -2.152550 0.088033 0.403333 0.003333 0.021854 3.000000 $ 18-Dec-2018 18:15:49.860 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.760000 121.026576 31.450000 159.000000 $ 18-Dec-2018 18:15:50.834 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.760000 121.032596 31.450000 159.000000 $ 18-Dec-2018 18:15:51.833 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.760000 121.031865 31.450000 159.000000 $ 18-Dec-2018 18:15:51.962 Surface Ops SBE41 Message -0.96 -0.960000 -2.010079 0.052412 -0.266667 0.068333 0.021133 3.000000 $ 18-Dec-2018 18:15:52.860 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.960000 121.035084 31.450000 159.000000 $ 18-Dec-2018 18:15:53.632 Surface Ops Processing Console Command: $go $ 18-Dec-2018 18:15:53.938 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.960000 121.047854 31.450000 159.000000 $ 18-Dec-2018 18:15:54.834 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -0.960000 121.030331 31.450000 159.000000 $ 18-Dec-2018 18:15:54.962 Surface Ops SBE41 Message -1.81 -1.810000 -1.790251 0.021140 0.283333 0.008333 0.019742 3.000000 $ 18-Dec-2018 18:15:55.863 Surface Ops RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: -1.810000 121.045500 31.450000 159.000000 $ 18-Dec-2018 18:15:56.632 Surface Ops Powering up 4330 Optode $ 18-Dec-2018 18:15:58.137 Surface Ops Sending Optode Wakeup $ 18-Dec-2018 18:16:02.144 Surface Ops Powering up OCR504 $ 18-Dec-2018 18:16:02.246 Surface Ops Closing old .eng file: \SD\data\2018-12-18T17-58-55.eng