$ Date Time State Comment Pressure Bel Pos Batt Volt Batt Amps CTD Temp CTD Sal Raw Press LPF Press LPF Vel Diff Vel Diff 2 Vel Slope of LPF Press. CTD Sample Period LPS331 Press LPS311 Temp SHT21 Humid SHT21 Temp PID SP PID PV PID Y1 PID Y2 PID I PID v PID u PID uCPS PID h FLBB Topt Tphase Rphase NO3 pH OCR GPS Irid Modem $ 07-Dec-2018 20:07:36.756 SM Not Running Reset Controller Status Register Value = 65792 $ 07-Dec-2018 20:07:36.766 SM Not Running File Name = \SD\data\2018-12-7T20-7-35.eng $ 07-Dec-2018 20:07:36.771 SM Not Running Volume Total Size: 7939817472 $ 07-Dec-2018 20:07:36.775 SM Not Running Volume Free Space: 7885979648 $ 07-Dec-2018 20:07:36.780 SM Not Running PlatVel PID K = 80 $ 07-Dec-2018 20:07:36.784 SM Not Running PlatVel PID Ti = 50000 $ 07-Dec-2018 20:07:36.788 SM Not Running PlatVel PID Td = 10 $ 07-Dec-2018 20:07:36.792 SM Not Running PlatVel PID Tf = 10 $ 07-Dec-2018 20:07:36.796 SM Not Running PlatVel PID Tt = 100 $ 07-Dec-2018 20:07:36.800 SM Not Running PlatVel PID B = 1 $ 07-Dec-2018 20:07:36.804 SM Not Running PlatVel PID uLow = -50 $ 07-Dec-2018 20:07:36.809 SM Not Running PlatVel PID uHigh = 50 $ 07-Dec-2018 20:07:36.813 SM Not Running PlatVel PID h = 3 $ 07-Dec-2018 20:07:36.816 SM Not Running Engr Logger Initialized $ 07-Dec-2018 20:07:36.820 SM Not Running Initializing Bluetooth Console $ 07-Dec-2018 20:07:37.825 SM Not Running Initializing GPS and synching time $ 07-Dec-2018 20:07:40.001 SM Not Running Creating Mission $ 07-Dec-2018 20:07:40.104 SM Not Running Maximum number of profiles = 10 $ 07-Dec-2018 20:07:40.208 SM Not Running Mission Timeout = 24:00:00 Mission Start Time: 12/07/2018 20:07:40 $ 07-Dec-2018 20:07:40.213 SM Not Running Recovery mode = True $ 07-Dec-2018 20:07:40.315 SM Not Running Park Sample Period = 00:01:00 $ 07-Dec-2018 20:07:40.515 SM Not Running Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7 $ 07-Dec-2018 20:07:40.619 SM Not Running Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:40.724 SM Not Running Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:40.828 SM Not Running Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:40.931 SM Not Running Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.035 SM Not Running Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.140 SM Not Running Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.244 SM Not Running Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.347 SM Not Running Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.451 SM Not Running Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.556 SM Not Running Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.660 SM Not Running Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.764 SM Not Running Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.867 SM Not Running Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:41.971 SM Not Running Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.076 SM Not Running Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.180 SM Not Running Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.284 SM Not Running Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.388 SM Not Running Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.492 SM Not Running Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.596 SM Not Running Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.700 SM Not Running Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.804 SM Not Running Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:42.908 SM Not Running Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:43.012 SM Not Running Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:43.116 SM Not Running Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:43.220 SM Not Running Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:43.325 SM Not Running Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.050, 00:00:00, 7 $ 07-Dec-2018 20:07:43.330 SM Not Running Initializing Buoyancy Engine $ 07-Dec-2018 20:07:43.532 SM Not Running Starting valve close $ 07-Dec-2018 20:07:43.536 Init Mission State Entry $ 07-Dec-2018 20:07:43.737 Init Mission Initializing FLBB $ 07-Dec-2018 20:07:48.243 Init Mission Sending FLBB stop command $ 07-Dec-2018 20:07:49.749 Init Mission Sending FLBB pkt command: $pkt 1 $ 07-Dec-2018 20:07:50.755 Init Mission Sending FLBB ave command: $ave 10 $ 07-Dec-2018 20:07:52.961 Init Mission Initializing Iridium Modem $ 07-Dec-2018 20:08:02.575 Init Mission Initializing SBE41 $ 07-Dec-2018 20:08:08.191 Init Mission Sending SBE41 stopProfile $ 07-Dec-2018 20:08:09.394 Init Mission pcutoff=1 $ 07-Dec-2018 20:08:10.500 Init Mission Sending outputPTSyes $ 07-Dec-2018 20:08:11.606 Init Mission Sending tsWait $ 07-Dec-2018 20:08:12.712 Init Mission Sending 11 bin setup commands $ 07-Dec-2018 20:08:19.353 Init Mission Initializing Optode $ 07-Dec-2018 20:08:19.959 Init Mission Sending Optode Wakeup $ 07-Dec-2018 20:08:25.164 Init Mission Initializing Pressure, Temperature, Humidity sensor $ 07-Dec-2018 20:08:25.874 Init Mission Set can pressure resolution to low $ 07-Dec-2018 20:08:26.078 Init Mission Set can pressure active $ 07-Dec-2018 20:08:26.183 Init Mission PTH Message 773.427734 21.808333 54.871124 22.873860 $ 07-Dec-2018 20:08:26.588 Init Mission Initializing MSC $ 07-Dec-2018 20:08:27.292 Init Mission MSC: OUT: INIT $ 07-Dec-2018 20:08:27.496 Init Mission Initializing Radiometer 1 $ 07-Dec-2018 20:08:28.170 Init Mission Powering down OCR504 $ 07-Dec-2018 20:08:33.276 Init Mission Powering up OCR504 $ 07-Dec-2018 20:07:56.578 Init Mission A3LA Message AT&D0 $ 07-Dec-2018 20:07:56.579 Init Mission A3LA Message OK $ 07-Dec-2018 20:07:57.578 Init Mission A3LA Message AT&K0 $ 07-Dec-2018 20:07:57.580 Init Mission A3LA Message OK $ 07-Dec-2018 20:07:58.581 Init Mission A3LA Message AT+SBDD2 $ 07-Dec-2018 20:07:58.583 Init Mission A3LA Message 0 $ 07-Dec-2018 20:07:58.584 Init Mission A3LA Message $ 07-Dec-2018 20:07:58.586 Init Mission A3LA Message OK $ 07-Dec-2018 20:07:59.587 Init Mission A3LA Message AT+GSN $ 07-Dec-2018 20:07:59.596 Init Mission A3LA Message 300125060561320 $ 07-Dec-2018 20:07:59.597 Init Mission A3LA Message $ 07-Dec-2018 20:07:59.599 Init Mission A3LA Message OK $ 07-Dec-2018 20:08:00.826 Init Mission A3LA Message AT+SBDC $ 07-Dec-2018 20:08:00.827 Init Mission A3LA Message 0 $ 07-Dec-2018 20:08:00.828 Init Mission A3LA Message $ 07-Dec-2018 20:08:00.830 Init Mission A3LA Message OK $ 07-Dec-2018 20:08:43.463 Init Mission PTH Message 773.427734 21.833333 54.871124 22.884585 $ 07-Dec-2018 20:08:43.868 Init Mission RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 129.143320 31.900000 97.000000 $ 07-Dec-2018 20:08:44.083 Init Mission Starting valve close $ 07-Dec-2018 20:08:46.383 Init Mission Closed valve isValveOpen = false $ 07-Dec-2018 20:08:46.586 Init Mission Starting valve open $ 07-Dec-2018 20:08:48.692 Init Mission Opened valve isValveOpen = true $ 07-Dec-2018 20:08:48.798 Init Mission Starting valve close $ 07-Dec-2018 20:08:51.003 Init Mission Closed valve isValveOpen = false $ 07-Dec-2018 20:08:01.586 Init Mission A3LA Message ATEn=0 $ 07-Dec-2018 20:08:01.588 Init Mission A3LA Message OK $ 07-Dec-2018 20:08:02.685 Init Mission A3LA Message $ 07-Dec-2018 20:08:02.686 Init Mission A3LA Message 8988169234000597401 $ 07-Dec-2018 20:08:02.686 Init Mission A3LA Message $ 07-Dec-2018 20:08:02.686 Init Mission A3LA Message OK $ 07-Dec-2018 20:08:08.424 Init Mission Unparsed SBE41 Message S>stopprofile $ 07-Dec-2018 20:08:09.609 Init Mission Unparsed SBE41 Message ?cmd S>pcutoff=1 $ 07-Dec-2018 20:08:10.717 Init Mission Unparsed SBE41 Message S>outputpts=y $ 07-Dec-2018 20:08:11.820 Init Mission Unparsed SBE41 Message S>tswait=2 $ 07-Dec-2018 20:08:12.944 Init Mission Unparsed SBE41 Message S>autobinavg=n $ 07-Dec-2018 20:08:13.379 Init Mission Unparsed SBE41 Message S>top_bin_interval=2 $ 07-Dec-2018 20:08:13.870 Init Mission Unparsed SBE41 Message S>top_bin_size=2 $ 07-Dec-2018 20:08:14.387 Init Mission Unparsed SBE41 Message S>top_bin_max=10 $ 07-Dec-2018 20:08:14.904 Init Mission Unparsed SBE41 Message S>middle_bin_interval=2 $ 07-Dec-2018 20:08:56.053 Init Mission RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 250.000000 31.900000 97.000000 $ 07-Dec-2018 20:08:56.268 Init Mission Starting valve open $ 07-Dec-2018 20:08:56.772 Init Mission Bellows inside limits $ 07-Dec-2018 20:08:15.395 Init Mission Unparsed SBE41 Message S>middle_bin_size=2 $ 07-Dec-2018 20:08:15.896 Init Mission Unparsed SBE41 Message S>middle_bin_max=20 $ 07-Dec-2018 20:08:16.405 Init Mission Unparsed SBE41 Message S>bottom_bin_interval=2 $ 07-Dec-2018 20:08:16.896 Init Mission Unparsed SBE41 Message S>bottom_bin_size=2 $ 07-Dec-2018 20:08:17.410 Init Mission Unparsed SBE41 Message S>includetransitionbin=n $ 07-Dec-2018 20:08:17.889 Init Mission Unparsed SBE41 Message S>includenbin=y $ 07-Dec-2018 20:08:21.205 Init Mission Optode Message *,ERROR,SYNTAX ERROR $ 07-Dec-2018 20:08:22.219 Init Mission Optode Message *,ERROR,PROTECTED PROPERTY $ 07-Dec-2018 20:08:23.234 Init Mission Optode Message *,ERROR,PROTECTED PROPERTY $ 07-Dec-2018 20:08:59.843 Init Mission MSC: RX: $ 07-Dec-2018 20:09:00.046 Init Mission MSC: RX: $ 07-Dec-2018 20:09:00.249 Init Mission MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initializing... $ 07-Dec-2018 20:09:00.555 Init Mission MSC: RX: MBARI Serial Number : 0777 $ 07-Dec-2018 20:09:00.661 Init Mission MSC: RX: CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 $ 07-Dec-2018 20:09:01.065 Init Mission MSC: RX: CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 $ 07-Dec-2018 20:09:01.272 Init Mission Radiometer Message Satlantic OCR-504 Multispectral Radiometer $ 07-Dec-2018 20:09:01.883 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 127.026536 31.900000 97.000000 $ 07-Dec-2018 20:09:03.499 Init Mission Increasing bellows position 128.297135 $ 07-Dec-2018 20:09:06.011 Init Mission Increasing bellows position 128.521338 $ 07-Dec-2018 20:09:08.424 Init Mission Increasing bellows position 128.751464 $ 07-Dec-2018 20:09:10.837 Init Mission Increasing bellows position 128.789447 $ 07-Dec-2018 20:09:13.250 Init Mission Increasing bellows position 128.847860 $ 07-Dec-2018 20:09:15.762 Init Mission Increasing bellows position 128.847227 $ 07-Dec-2018 20:09:18.175 Init Mission Increasing bellows position 128.883615 $ 07-Dec-2018 20:09:20.588 Init Mission Increasing bellows position 128.909260 $ 07-Dec-2018 20:09:23.000 Init Mission Increasing bellows position 128.894053 $ 07-Dec-2018 20:09:25.413 Init Mission Increasing bellows position 128.887862 $ 07-Dec-2018 20:09:28.228 Init Mission Decreasing bellows position 128.919147 $ 07-Dec-2018 20:09:30.641 Init Mission Decreasing bellows position 128.955401 $ 07-Dec-2018 20:09:33.053 Init Mission Decreasing bellows position 128.969520 $ 07-Dec-2018 20:09:35.466 Init Mission Decreasing bellows position 128.976911 $ 07-Dec-2018 20:09:37.977 Init Mission Decreasing bellows position 128.981799 $ 07-Dec-2018 20:09:40.390 Init Mission Decreasing bellows position 128.998734 $ 07-Dec-2018 20:09:42.803 Init Mission Decreasing bellows position 129.008733 $ 07-Dec-2018 20:09:45.216 Init Mission Decreasing bellows position 129.017480 $ 07-Dec-2018 20:09:47.727 Init Mission Decreasing bellows position 128.996320 $ 07-Dec-2018 20:09:50.141 Init Mission Decreasing bellows position 129.040949 $ 07-Dec-2018 20:09:52.354 Init Mission Radiometer Message Copyright (C) 2011, Satlantic Inc. All rights reserved. $ 07-Dec-2018 20:09:52.667 Init Mission Radiometer Message Firmware version: 5.1.0 - SatNet Type B $ 07-Dec-2018 20:09:52.882 Init Mission Radiometer Message Instrument: SATFI4 $ 07-Dec-2018 20:09:53.193 Init Mission Radiometer Message S/N: 0287 $ 07-Dec-2018 20:09:53.504 Init Mission Radiometer Message Reset Source: Power $ 07-Dec-2018 20:09:53.814 Init Mission Radiometer Message Press for command console. $ 07-Dec-2018 20:09:54.127 Init Mission Radiometer Message Initializing system. Please wait... $ 07-Dec-2018 20:09:54.536 Init Mission MSC: RX: CF Card: Size=256614400 Avail=99.17% $ 07-Dec-2018 20:09:54.841 Init Mission MSC: RX: CF2 Power Up (GMT): Thu Jan 26 02:33:16 2012 $ 07-Dec-2018 20:09:55.049 Init Mission MSC: RX: CF2 RTC Time (GMT): Thu Jan 26 02:33:20 2012 $ 07-Dec-2018 20:09:55.354 Init Mission MSC: RX: Adjusted Local Time: Wed Jan 25 18:33:20 2012 $ 07-Dec-2018 20:09:55.758 Init Mission MSC: RX: TZ Offset (GMT - LOCAL) : +8.00 hrs. $ 07-Dec-2018 20:09:55.966 Init Mission MSC: RX: RTC delta (CF2 - DS3234) : -1.00 secs. $ 07-Dec-2018 20:09:56.271 Init Mission MSC: RX: System Batt Voltage = 11.764 $ 07-Dec-2018 20:09:56.475 Init Mission MSC: RX: System Load Current = 2.62e-02 $ 07-Dec-2018 20:09:56.877 Init Mission MSC: RX: Housing Temperature = +21.56C = +70.81F $ 07-Dec-2018 20:09:57.384 Init Mission PTH Message 773.250977 22.125000 54.443878 23.109812 $ 07-Dec-2018 20:09:57.789 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 129.034035 31.825000 153.000000 $ 07-Dec-2018 20:09:58.102 Init Mission MSC: RX: Housing Humidity = 56.0% = 12.4C (DP) $ 07-Dec-2018 20:09:58.409 Init Mission MSC: RX: Power Cycle Count = 117 $ 07-Dec-2018 20:09:58.516 Init Mission MSC: RX: System Reset Count = 121 $ 07-Dec-2018 20:09:58.722 Init Mission MSC: RX: System Error Count = 55 $ 07-Dec-2018 20:09:59.022 Init Mission MSC: RX: Last System Error = -110 $ 07-Dec-2018 20:09:59.226 Init Mission MSC: RX: Last Error Time = Thu Jan 26 02:07:28 2012 $ 07-Dec-2018 20:09:59.531 Init Mission MSC: RX: ISUS Error Count = 0 $ 07-Dec-2018 20:09:59.735 Init Mission MSC: RX: Last ISUS Error = 0 $ 07-Dec-2018 20:09:59.841 Init Mission MSC: RX: Last Error Time = Thu Jan 1 00:00:00 1970 $ 07-Dec-2018 20:10:00.245 Init Mission MSC: RX: DURA Error Count = 0 $ 07-Dec-2018 20:10:00.449 Init Mission MSC: RX: Last DURA Error = 0 $ 07-Dec-2018 20:10:00.555 Init Mission MSC: RX: Last Error Time = Thu Jan 1 00:00:00 1970 $ 07-Dec-2018 20:10:00.958 Init Mission MSC: RX: Fiberlite Odometer = 100:09:56 = 360596 secs $ 07-Dec-2018 20:10:01.263 Init Mission MSC: RX: Fiberlite Cycles = 209 $ 07-Dec-2018 20:10:01.369 Init Mission MSC: RX: Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 $ 07-Dec-2018 20:10:01.774 Init Mission MSC: RX: Zeiss Coef File Found 4 coefs loaded. $ 07-Dec-2018 20:10:02.183 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.000000 129.043005 31.825000 153.000000 $ 07-Dec-2018 20:10:02.397 Init Mission Sending SBE41 ds command $ 07-Dec-2018 20:10:02.600 Init Mission Sending ds command $ 07-Dec-2018 20:10:02.909 Init Mission MSC: RX: Ecoef File Found 256 coefs loaded. $ 07-Dec-2018 20:10:03.122 Init Mission MSC: RX: There are 60 records in the error file! $ 07-Dec-2018 20:10:03.534 Init Mission MSC: RX: MBARI Sensor Controller (ISUS/DURA) Initialized $ 07-Dec-2018 20:10:03.839 Init Mission MSC: RX: Auto Shutdown in 10 hours at: Thu Jan 26 12:33:21 2012 $ 07-Dec-2018 20:10:04.144 Init Mission MSC: RX: Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode $ 07-Dec-2018 20:10:04.354 Init Mission Radiometer Message Autonomous operation enabled. $ 07-Dec-2018 20:08:38.909 Init Mission SBE41 Message 0.06 0.060000 0.000001 0.000000 -0.020000 -0.010000 -0.000000 3.000000 $ 07-Dec-2018 20:10:05.292 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.051641 31.825000 153.000000 $ 07-Dec-2018 20:10:05.508 Init Mission Sending SBE41 ds command $ 07-Dec-2018 20:10:06.013 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.042767 31.825000 153.000000 $ 07-Dec-2018 20:10:06.509 Init Mission Sending SBE41 ds command $ 07-Dec-2018 20:10:06.915 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.048124 31.825000 153.000000 $ 07-Dec-2018 20:10:07.509 Init Mission Sending SBE41 ds command $ 07-Dec-2018 20:10:02.906 Init Mission Unparsed SBE41 Message S>ds $ 07-Dec-2018 20:10:03.115 Init Mission Unparsed SBE41 Message firmware compilation date: 18 December 2007 09:20 $ 07-Dec-2018 20:10:03.117 Init Mission Unparsed SBE41 Message stop profile when pressure is less than = 1.0 decibars $ 07-Dec-2018 20:10:03.118 Init Mission Unparsed SBE41 Message automatic bin averaging at end of profile disabled $ 07-Dec-2018 20:10:03.119 Init Mission Unparsed SBE41 Message number of samples = 46 $ 07-Dec-2018 20:10:03.119 Init Mission Unparsed SBE41 Message number of bins = 0 $ 07-Dec-2018 20:10:03.219 Init Mission Unparsed SBE41 Message top bin interval = 2 $ 07-Dec-2018 20:10:03.220 Init Mission Unparsed SBE41 Message top bin size = 2 $ 07-Dec-2018 20:10:03.221 Init Mission Unparsed SBE41 Message top bin max = 10 $ 07-Dec-2018 20:10:03.428 Init Mission Unparsed SBE41 Message middle bin interval = 2 $ 07-Dec-2018 20:10:03.429 Init Mission Unparsed SBE41 Message middle bin size = 2 $ 07-Dec-2018 20:10:03.429 Init Mission Unparsed SBE41 Message middle bin max = 20 $ 07-Dec-2018 20:10:03.430 Init Mission Unparsed SBE41 Message bottom bin interval = 2 $ 07-Dec-2018 20:10:03.431 Init Mission Unparsed SBE41 Message bottom bin size = 2 $ 07-Dec-2018 20:10:12.394 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.044876 31.825000 153.000000 $ 07-Dec-2018 20:10:12.610 Init Mission Sending SBE41 ds command $ 07-Dec-2018 20:10:03.432 Init Mission Unparsed SBE41 Message do not include two transition bins $ 07-Dec-2018 20:10:03.433 Init Mission Unparsed SBE41 Message include samples per bin $ 07-Dec-2018 20:10:03.532 Init Mission Unparsed SBE41 Message pumped take sample wait time = 2 sec $ 07-Dec-2018 20:10:03.533 Init Mission Unparsed SBE41 Message real-time output is PTS $ 07-Dec-2018 20:10:14.396 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.039064 31.825000 153.000000 $ 07-Dec-2018 20:10:14.707 Init Mission Sending SBE41 ds command $ 07-Dec-2018 20:10:15.112 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.054859 31.825000 153.000000 $ 07-Dec-2018 20:10:15.707 Init Mission Sending SBE41 dc command $ 07-Dec-2018 20:10:15.910 Init Mission Sending dc command $ 07-Dec-2018 20:10:16.322 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.058801 31.825000 153.000000 $ 07-Dec-2018 20:10:16.707 Init Mission Sending SBE41 dc command $ 07-Dec-2018 20:10:16.117 Init Mission Unparsed SBE41 Message S>dc $ 07-Dec-2018 20:10:16.119 Init Mission Unparsed SBE41 Message temperature: 15-mar-14 $ 07-Dec-2018 20:10:16.145 Init Mission Unparsed SBE41 Message TA0 = 3.536242e-05 $ 07-Dec-2018 20:10:16.182 Init Mission Unparsed SBE41 Message TA1 = 2.674251e-04 $ 07-Dec-2018 20:10:16.217 Init Mission Unparsed SBE41 Message TA2 = -1.901062e-06 $ 07-Dec-2018 20:10:16.253 Init Mission Unparsed SBE41 Message TA3 = 1.365250e-07 $ 07-Dec-2018 20:10:16.289 Init Mission Unparsed SBE41 Message conductivity: 15-mar-14 $ 07-Dec-2018 20:10:16.535 Init Mission Unparsed SBE41 Message G = -9.858232e-01 $ 07-Dec-2018 20:10:16.536 Init Mission Unparsed SBE41 Message H = 1.476071e-01 $ 07-Dec-2018 20:10:16.537 Init Mission Unparsed SBE41 Message I = -3.292498e-04 $ 07-Dec-2018 20:10:16.537 Init Mission Unparsed SBE41 Message J = 4.505543e-05 $ 07-Dec-2018 20:10:16.538 Init Mission Unparsed SBE41 Message CPCOR = -9.570001e-08 $ 07-Dec-2018 20:10:16.539 Init Mission Unparsed SBE41 Message CTCOR = 3.250000e-06 $ 07-Dec-2018 20:10:16.638 Init Mission Unparsed SBE41 Message WBOTC = -3.218098e-07 $ 07-Dec-2018 20:10:16.640 Init Mission Unparsed SBE41 Message pressure S/N = 4004719, range = 2900 psia: 10-mar-14 $ 07-Dec-2018 20:10:21.923 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.053660 31.825000 153.000000 $ 07-Dec-2018 20:10:22.140 Init Mission Sending SBE41 dc command $ 07-Dec-2018 20:10:16.658 Init Mission Unparsed SBE41 Message PA0 = 1.629284e-01 $ 07-Dec-2018 20:10:16.693 Init Mission Unparsed SBE41 Message PA1 = 1.404717e-01 $ 07-Dec-2018 20:10:16.812 Init Mission Unparsed SBE41 Message PA2 = -3.503310e-08 $ 07-Dec-2018 20:10:16.813 Init Mission Unparsed SBE41 Message PTCA0 = 2.758681e+01 $ 07-Dec-2018 20:10:16.814 Init Mission Unparsed SBE41 Message PTCA1 = 2.201518e-02 $ 07-Dec-2018 20:10:16.916 Init Mission Unparsed SBE41 Message PTCA2 = 1.374282e-03 $ 07-Dec-2018 20:10:16.917 Init Mission Unparsed SBE41 Message PTCB0 = 2.510888e+01 $ 07-Dec-2018 20:10:17.138 Init Mission Unparsed SBE41 Message PTCB1 = 1.175000e-03 $ 07-Dec-2018 20:10:17.139 Init Mission Unparsed SBE41 Message PTCB2 = 0.000000e+00 $ 07-Dec-2018 20:10:17.140 Init Mission Unparsed SBE41 Message PTHA0 = -7.442904e+01 $ 07-Dec-2018 20:10:17.141 Init Mission Unparsed SBE41 Message PTHA1 = 4.994783e-02 $ 07-Dec-2018 20:10:17.141 Init Mission Unparsed SBE41 Message PTHA2 = -3.966033e-07 $ 07-Dec-2018 20:10:17.142 Init Mission Unparsed SBE41 Message POFFSET = 0.000000e+00 $ 07-Dec-2018 20:10:26.705 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.067257 31.825000 153.000000 $ 07-Dec-2018 20:10:26.920 Init Mission Sending SBE41 dc command $ 07-Dec-2018 20:10:27.424 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.069880 31.825000 153.000000 $ 07-Dec-2018 20:10:28.122 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.060000 129.086167 31.825000 153.000000 $ 07-Dec-2018 20:10:28.920 Init Mission Sending Optode GetAll $ 07-Dec-2018 20:10:29.027 Init Mission Sending Optode Wakeup $ 07-Dec-2018 20:10:28.908 Init Mission SBE41 Message -0.13 -0.130000 0.000126 0.000001 0.063333 0.021667 -0.000000 3.000000 $ 07-Dec-2018 20:10:29.898 Init Mission Optode Message %!Product Name,4330,1532,Optode Sensor $ 07-Dec-2018 20:10:29.931 Init Mission Optode Message Product Number,4330,1532,4330 $ 07-Dec-2018 20:10:29.962 Init Mission Optode Message Serial Number,4330,1532,1532 $ 07-Dec-2018 20:10:29.988 Init Mission Optode Message SW ID,4330,1532,1940006 $ 07-Dec-2018 20:10:30.017 Init Mission Optode Message SW Version,4330,1532,4,8,1 $ 07-Dec-2018 20:10:30.058 Init Mission Optode Message Node Description,4330,1532,optode 1532 $ 07-Dec-2018 20:10:30.077 Init Mission Optode Message Owner,4330,1532, $ 07-Dec-2018 20:10:30.108 Init Mission Optode Message Salinity[PSU],4330,1532,0.00 $ 07-Dec-2018 20:10:30.184 Init Mission Optode Message PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00 $ 07-Dec-2018 20:10:30.210 Init Mission Optode Message FoilID,4330,1532,1206E $ 07-Dec-2018 20:10:30.429 Init Mission Optode Message FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04 $ 07-Dec-2018 20:10:30.644 Init Mission Optode Message FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00 $ 07-Dec-2018 20:10:30.726 Init Mission Optode Message FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0 $ 07-Dec-2018 20:10:37.716 Init Mission Normal State Exit $ 07-Dec-2018 20:10:37.919 Init Mission RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 129.058398 31.825000 153.000000 $ 07-Dec-2018 20:10:38.138 Init Profile State Entry $ 07-Dec-2018 20:10:38.343 Init Profile Initializing SBE 41 LPF $ 07-Dec-2018 20:10:38.656 Init Profile Sending SBE41 stopProfile $ 07-Dec-2018 20:10:39.763 Init Profile Resetting SBE41 with qsr $ 07-Dec-2018 20:10:39.868 Init Profile Sending qsr command $ 07-Dec-2018 20:10:30.810 Init Profile Optode Message FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0 $ 07-Dec-2018 20:10:30.928 Init Profile Optode Message SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00 $ 07-Dec-2018 20:10:30.977 Init Profile Optode Message ConcCoef,4330,1532,-1.549127E+00,1.068129E+00 $ 07-Dec-2018 20:10:31.014 Init Profile Optode Message NomAirPress[hPa],4330,1532,1013.25 $ 07-Dec-2018 20:10:31.044 Init Profile Optode Message NomAirMix,4330,1532,0.20946 $ 07-Dec-2018 20:10:31.085 Init Profile Optode Message CalDataSat[Deg],4330,1532,31.61,10.06 $ 07-Dec-2018 20:10:31.126 Init Profile Optode Message CalDataAPress[hPa],4330,1532,1002.000 $ 07-Dec-2018 20:10:31.169 Init Profile Optode Message CalDataZero[Deg],4330,1532,61.907,21.413 $ 07-Dec-2018 20:10:31.208 Init Profile Optode Message Mode,4330,1532,Smart Sensor Terminal $ 07-Dec-2018 20:10:31.238 Init Profile Optode Message Enable Sleep,4330,1532,Yes $ 07-Dec-2018 20:10:31.273 Init Profile Optode Message Enable Polled Mode,4330,1532,Yes $ 07-Dec-2018 20:10:31.301 Init Profile Optode Message Enable Text,4330,1532,Yes $ 07-Dec-2018 20:10:31.339 Init Profile Optode Message Enable Decimalformat,4330,1532,Yes $ 07-Dec-2018 20:10:31.387 Init Profile Optode Message Analog TempLimit[Deg.C],4330,1532,-5.00,35.00 $ 07-Dec-2018 20:10:31.436 Init Profile Optode Message Analog ConcLimit[Deg.C],4330,1532,0.00,800.00 $ 07-Dec-2018 20:10:46.920 Init Profile Normal State Exit $ 07-Dec-2018 20:10:47.026 Init Profile RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.130000 129.082195 31.825000 153.000000 $ 07-Dec-2018 20:10:47.345 Init Profile ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:09.2058660 $ 07-Dec-2018 20:10:47.749 Surface Ops Set Bellows State Entry $ 07-Dec-2018 20:10:47.959 Surface Ops Set Bellows Inflating bellows to Surface Ops position = 155.0 at 200000 cps $ 07-Dec-2018 20:10:31.484 Surface Ops Set Bellows Optode Message Analog SatLimit[Deg.C],4330,1532,0.00,200.00 $ 07-Dec-2018 20:10:31.534 Surface Ops Set Bellows Optode Message Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00 $ 07-Dec-2018 20:10:31.576 Surface Ops Set Bellows Optode Message Analog Output,4330,1532,O2Concentration $ 07-Dec-2018 20:10:31.628 Surface Ops Set Bellows Optode Message Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00 $ 07-Dec-2018 20:10:31.680 Surface Ops Set Bellows Optode Message Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00 $ 07-Dec-2018 20:10:31.717 Surface Ops Set Bellows Optode Message Enable AirSaturation,4330,1532,Yes $ 07-Dec-2018 20:10:31.749 Surface Ops Set Bellows Optode Message Enable Rawdata,4330,1532,Yes $ 07-Dec-2018 20:10:31.784 Surface Ops Set Bellows Optode Message Enable Temperature,4330,1532,Yes $ 07-Dec-2018 20:10:31.821 Surface Ops Set Bellows Optode Message Enable HumidityComp,4330,1532,Yes $ 07-Dec-2018 20:10:31.854 Surface Ops Set Bellows Optode Message Enable SVUformula,4330,1532,No $ 07-Dec-2018 20:10:31.884 Surface Ops Set Bellows Optode Message Interval[s],4330,1532,30.000 $ 07-Dec-2018 20:10:31.894 Surface Ops Set Bellows SBE41 Message -0.16 -0.160000 -0.130000 -0.000000 0.010000 0.005000 0.000000 3.000000 $ 07-Dec-2018 20:10:31.907 Surface Ops Set Bellows Optode Message Location,4330,1532, $ 07-Dec-2018 20:10:31.958 Surface Ops Set Bellows Optode Message Geographic Position,4330,1532,60.323605,5.37225 $ 07-Dec-2018 20:10:31.988 Surface Ops Set Bellows Optode Message Vertical Position,4330,1532, $ 07-Dec-2018 20:10:32.012 Surface Ops Set Bellows Optode Message Reference,4330,1532, $ 07-Dec-2018 20:10:53.839 Surface Ops Set Bellows Normal State Exit $ 07-Dec-2018 20:10:53.946 Surface Ops Set Bellows RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.160000 129.084311 31.825000 153.000000 $ 07-Dec-2018 20:10:54.365 Surface Ops Set Bellows ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:06.6150482 $ 07-Dec-2018 20:10:54.671 Pre-Mission Delay State Entry $ 07-Dec-2018 20:10:32.015 Pre-Mission Delay Optode Message # $ 07-Dec-2018 20:10:35.263 Pre-Mission Delay SBE41 Message 1.30 1.300000 -0.130051 -0.000001 -0.486667 -0.238333 0.000000 3.000000 $ 07-Dec-2018 20:10:55.826 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 1.300000 129.105963 31.825000 153.000000 $ 07-Dec-2018 20:10:56.042 Pre-Mission Delay ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.3707100 $ 07-Dec-2018 20:10:38.137 Pre-Mission Delay SBE41 Message -3.69 -3.690000 -0.127724 0.000029 1.663333 0.588333 -0.000003 3.000000 $ 07-Dec-2018 20:10:38.874 Pre-Mission Delay Unparsed SBE41 Message S>stopprofile $ 07-Dec-2018 20:10:40.174 Pre-Mission Delay Unparsed SBE41 Message ?cmd S>qsr $ 07-Dec-2018 20:10:40.175 Pre-Mission Delay Unparsed SBE41 Message powering down $ 07-Dec-2018 20:10:41.750 Pre-Mission Delay Unparsed SBE41 Message S>SBE 41CP UW V 2.0 $ 07-Dec-2018 20:10:58.260 Pre-Mission Delay PTH Message 773.445312 22.391667 53.978485 23.335039 $ 07-Dec-2018 20:10:58.669 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -3.690000 129.109673 31.825000 155.500000 $ 07-Dec-2018 20:10:58.886 Pre-Mission Delay ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.5387159 $ 07-Dec-2018 20:10:42.291 Pre-Mission Delay Unparsed SBE41 Message S> $ 07-Dec-2018 20:10:44.190 Pre-Mission Delay SBE41 Message -0.56 -0.560000 -0.106263 0.000191 -1.043333 0.310000 -0.000032 3.000000 $ 07-Dec-2018 20:10:47.025 Pre-Mission Delay SBE41 Message -0.11 -0.110000 -0.077152 -0.000414 -0.150000 -0.596667 -0.000096 3.000000 $ 07-Dec-2018 20:11:00.472 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.110000 129.088707 31.825000 155.500000 $ 07-Dec-2018 20:11:00.686 Pre-Mission Delay ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4941136 $ 07-Dec-2018 20:10:50.148 Pre-Mission Delay SBE41 Message -2.02 -2.020000 -0.189450 -0.003765 0.636667 0.243333 -0.000017 3.000000 $ 07-Dec-2018 20:10:53.003 Pre-Mission Delay SBE41 Message 0.14 0.140000 -0.571786 -0.005373 -0.720000 -0.041667 0.000533 3.000000 $ 07-Dec-2018 20:11:01.952 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.140000 129.096016 31.825000 155.500000 $ 07-Dec-2018 20:11:02.266 Pre-Mission Delay ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.1746877 $ 07-Dec-2018 20:11:02.777 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 0.140000 129.095338 31.825000 155.500000 $ 07-Dec-2018 20:10:56.039 Pre-Mission Delay SBE41 Message -0.13 -0.130000 -0.987717 0.008574 0.090000 -0.315000 0.001573 3.000000 $ 07-Dec-2018 20:10:59.191 Pre-Mission Delay SBE41 Message 1.96 1.960000 -1.096499 0.041547 -0.696667 -0.303333 0.002695 3.000000 $ 07-Dec-2018 20:11:01.911 Pre-Mission Delay SBE41 Message -0.15 -0.150000 -0.945699 0.074201 0.703333 0.003333 0.003566 3.000000 $ 07-Dec-2018 20:11:04.661 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.150000 129.111744 31.825000 155.500000 $ 07-Dec-2018 20:11:04.877 Pre-Mission Delay ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.4004946 $ 07-Dec-2018 20:11:04.975 Pre-Mission Delay SBE41 Message -0.14 -0.140000 -0.691691 0.084645 -0.003333 0.350000 0.004069 3.000000 $ 07-Dec-2018 20:11:05.812 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 129.102305 31.825000 155.500000 $ 07-Dec-2018 20:11:06.386 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 129.101872 31.825000 155.500000 $ 07-Dec-2018 20:11:07.385 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 129.115865 31.825000 155.500000 $ 07-Dec-2018 20:11:08.071 Pre-Mission Delay SBE41 Message -0.14 -0.140000 -0.281257 0.063656 0.000000 -0.001667 0.004025 3.000000 $ 07-Dec-2018 20:11:08.615 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 129.121162 31.825000 155.500000 $ 07-Dec-2018 20:11:09.387 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 129.119590 31.825000 155.500000 $ 07-Dec-2018 20:11:10.483 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: -0.140000 129.086487 31.825000 155.500000 $ 07-Dec-2018 20:11:10.892 Pre-Mission Delay SBE41 Message 2.45 2.450000 0.207550 0.010427 -0.863333 -0.431667 0.003365 3.000000 $ 07-Dec-2018 20:11:11.715 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.450000 129.101597 31.825000 155.500000 $ 07-Dec-2018 20:11:12.484 Pre-Mission Delay RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0 Pres, BP, BatV, BatI: 2.450000 129.107997 31.825000 155.500000