$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	GPS	Irid Modem	
$	05-Jul-2018	19:04:37.912	SM Not Running	Reset Controller Status Register Value = 65792

$	05-Jul-2018	19:04:38.118	SM Not Running	File Name = \SD\data\2018-7-5T19-4-36

$	05-Jul-2018	19:04:38.223	SM Not Running	Volume Total Size:     7939817472

$	05-Jul-2018	19:04:38.329	SM Not Running	Volume Free Space:     7929757696

$	05-Jul-2018	19:04:38.434	SM Not Running	PlatVel PID K = 352

$	05-Jul-2018	19:04:38.538	SM Not Running	PlatVel PID Ti = 50000

$	05-Jul-2018	19:04:38.643	SM Not Running	PlatVel PID Td = 44

$	05-Jul-2018	19:04:38.748	SM Not Running	PlatVel PID Tf = 10

$	05-Jul-2018	19:04:38.853	SM Not Running	PlatVel PID Tt = 100

$	05-Jul-2018	19:04:38.958	SM Not Running	PlatVel PID B = 1

$	05-Jul-2018	19:04:39.064	SM Not Running	PlatVel PID uLow = -41.666666666666664

$	05-Jul-2018	19:04:39.169	SM Not Running	PlatVel PID uHigh = 41.666666666666664

$	05-Jul-2018	19:04:39.274	SM Not Running	PlatVel PID h = 3

$	05-Jul-2018	19:04:39.378	SM Not Running	Engr Logger Initialized

$	05-Jul-2018	19:04:39.483	SM Not Running	Initializing Bluetooth Console

$	05-Jul-2018	19:04:40.589	SM Not Running	Initializing GPS and synching time

$	05-Jul-2018	19:04:42.001	SM Not Running	Creating Mission

$	05-Jul-2018	19:04:42.205	SM Not Running	Maximum number of profiles = 10

$	05-Jul-2018	19:04:42.409	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 07/05/2018 19:04:42

$	05-Jul-2018	19:04:42.616	SM Not Running	Recovery mode = True

$	05-Jul-2018	19:04:42.819	SM Not Running	Park Sample Period = 00:02:00

$	05-Jul-2018	19:04:43.120	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	05-Jul-2018	19:04:43.426	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:43.732	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:44.037	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:44.343	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:44.648	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:44.954	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:45.259	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:45.565	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:45.870	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:46.176	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:46.482	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:46.787	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:47.093	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:47.399	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:47.704	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:48.010	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:48.315	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:48.620	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:48.926	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:49.232	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:49.537	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:49.843	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:50.149	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:50.454	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:50.760	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:51.065	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:51.371	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.100, 00:00:00, 7

$	05-Jul-2018	19:04:51.675	SM Not Running	Initializing Buoyancy Engine

$	05-Jul-2018	19:04:51.879	SM Not Running	Starting valve close

$	05-Jul-2018	19:04:51.986	Init Mission	State Entry

$	05-Jul-2018	19:04:52.189	Init Mission	Initializing FLBB

$	05-Jul-2018	19:04:53.895	Init Mission	Sending FLBB stop command

$	05-Jul-2018	19:04:55.598	Init Mission	Sending FLBB pkt command: $pkt 1  

$	05-Jul-2018	19:04:56.803	Init Mission	Sending FLBB ave command: $ave 20  

$	05-Jul-2018	19:04:57.007	Init Mission	Initializing Iridium Modem
