$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	19-Dec-2018	17:03:14.874	SM Not Running	Reset Controller Status Register Value = 65792

$	19-Dec-2018	17:03:14.878	SM Not Running	File Name = \SD\data\cpf001.000.2018-12-19T16-59-47.eng

$	19-Dec-2018	17:03:14.884	SM Not Running	Volume Total Size:     7939817472

$	19-Dec-2018	17:03:14.888	SM Not Running	Volume Free Space:     7865237504

$	19-Dec-2018	17:03:14.892	SM Not Running	PlatVel PID K = 80

$	19-Dec-2018	17:03:14.896	SM Not Running	PlatVel PID Ti = 50000

$	19-Dec-2018	17:03:14.900	SM Not Running	PlatVel PID Td = 10

$	19-Dec-2018	17:03:14.904	SM Not Running	PlatVel PID Tf = 10

$	19-Dec-2018	17:03:14.908	SM Not Running	PlatVel PID Tt = 100

$	19-Dec-2018	17:03:14.912	SM Not Running	PlatVel PID B = 1

$	19-Dec-2018	17:03:14.917	SM Not Running	PlatVel PID uLow = -50

$	19-Dec-2018	17:03:14.921	SM Not Running	PlatVel PID uHigh = 50

$	19-Dec-2018	17:03:14.925	SM Not Running	PlatVel PID h = 3

$	19-Dec-2018	17:03:14.929	SM Not Running	Engr Logger Initialized

$	19-Dec-2018	17:03:15.420	SM Not Running	Initializing Bluetooth Console

$	19-Dec-2018	17:03:16.425	SM Not Running	Initializing GPS and synching time

$	19-Dec-2018	17:03:18.001	SM Not Running	Creating Mission

$	19-Dec-2018	17:03:18.104	SM Not Running	Maximum number of profiles = 10

$	19-Dec-2018	17:03:18.208	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 12/19/2018 17:03:18

$	19-Dec-2018	17:03:18.314	SM Not Running	Recovery mode = True

$	19-Dec-2018	17:03:18.418	SM Not Running	Park Sample Period = 00:01:00

$	19-Dec-2018	17:03:18.524	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	19-Dec-2018	17:03:18.631	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:18.738	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:18.845	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:18.952	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.061	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.169	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.275	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.382	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.489	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.596	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.703	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.811	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:19.918	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.026	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.133	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.240	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.347	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.454	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.566	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.673	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.780	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.887	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:20.996	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:21.104	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:21.213	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:21.320	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:21.430	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.100, 00:00:00, 7

$	19-Dec-2018	17:03:21.435	SM Not Running	Initializing Buoyancy Engine

$	19-Dec-2018	17:03:21.636	SM Not Running	Starting valve close

$	19-Dec-2018	17:03:21.641	Init Mission	State Entry

$	19-Dec-2018	17:03:21.743	Init Mission	Initializing FLBB

$	19-Dec-2018	17:03:26.349	Init Mission	Sending FLBB stop command

$	19-Dec-2018	17:03:27.854	Init Mission	Sending FLBB pkt command: $pkt 1  

$	19-Dec-2018	17:03:28.959	Init Mission	Sending FLBB ave command: $ave 10  

$	19-Dec-2018	17:03:30.966	Init Mission	Initializing Iridium Modem

$	19-Dec-2018	17:03:40.571	Init Mission	Initializing SBE41

$	19-Dec-2018	17:03:46.181	Init Mission	Sending SBE41 stopProfile

$	19-Dec-2018	17:03:47.186	Init Mission	pcutoff=1 

$	19-Dec-2018	17:03:48.190	Init Mission	Sending outputPTSyes

$	19-Dec-2018	17:03:49.195	Init Mission	Sending tsWait

$	19-Dec-2018	17:03:50.202	Init Mission	Sending 11 bin setup commands

$	19-Dec-2018	17:03:56.728	Init Mission	Initializing Optode

$	19-Dec-2018	17:03:57.330	Init Mission	Sending Optode Wakeup

$	19-Dec-2018	17:04:02.337	Init Mission	Initializing Pressure, Temperature, Humidity sensor

$	19-Dec-2018	17:04:02.844	Init Mission	Set can pressure resolution to low

$	19-Dec-2018	17:04:02.947	Init Mission	Set can pressure active

$	19-Dec-2018	17:04:02.951	Init Mission	PTH Message														776.475342	20.366667	56.061310	21.533223																			

$	19-Dec-2018	17:04:03.153	Init Mission	Initializing MSC

$	19-Dec-2018	17:04:03.755	Init Mission	MSC: OUT: INIT

$	19-Dec-2018	17:04:03.859	Init Mission	Initializing Radiometer 1

$	19-Dec-2018	17:04:04.371	Init Mission	Powering down OCR504

$	19-Dec-2018	17:04:09.375	Init Mission	Powering up OCR504

$	19-Dec-2018	17:03:34.573	Init Mission	A3LA Message																																			AT&D0   	

$	19-Dec-2018	17:03:34.575	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:03:35.574	Init Mission	A3LA Message																																			AT&K0   	

$	19-Dec-2018	17:03:35.576	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:03:36.577	Init Mission	A3LA Message																																			AT+SBDD2   	

$	19-Dec-2018	17:03:36.579	Init Mission	A3LA Message																																			0  	

$	19-Dec-2018	17:03:36.580	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	17:03:36.582	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:03:37.582	Init Mission	A3LA Message																																			AT+GSN    	

$	19-Dec-2018	17:03:37.591	Init Mission	A3LA Message																																			300125060561320  	

$	19-Dec-2018	17:03:37.592	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	17:03:37.595	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:03:38.991	Init Mission	A3LA Message																																			AT+SBDC   	

$	19-Dec-2018	17:03:38.992	Init Mission	A3LA Message																																			0  	

$	19-Dec-2018	17:03:38.993	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	17:03:38.995	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:04:16.220	Init Mission	PTH Message														776.475342	20.491667	56.099457	21.533223																			

$	19-Dec-2018	17:04:16.423	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	29.925000	120.500000																																

$	19-Dec-2018	17:04:16.534	Init Mission	Starting valve close

$	19-Dec-2018	17:04:18.538	Init Mission	Closed valve isValveOpen = false

$	19-Dec-2018	17:04:18.734	Init Mission	Starting valve open

$	19-Dec-2018	17:04:20.739	Init Mission	Opened valve isValveOpen = true

$	19-Dec-2018	17:04:20.934	Init Mission	Starting valve close

$	19-Dec-2018	17:04:22.940	Init Mission	Closed valve isValveOpen = false

$	19-Dec-2018	17:03:39.582	Init Mission	A3LA Message																																			ATEn=0   	

$	19-Dec-2018	17:03:39.584	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:03:40.739	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	17:03:40.750	Init Mission	A3LA Message																																			8988169234000597401  	

$	19-Dec-2018	17:03:40.751	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	17:03:40.753	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	17:03:46.296	Init Mission	Unparsed SBE41 Message						S>stopprofile  																														

$	19-Dec-2018	17:03:47.299	Init Mission	Unparsed SBE41 Message						?cmd S>pcutoff=1  																														

$	19-Dec-2018	17:03:48.306	Init Mission	Unparsed SBE41 Message						S>outputpts=y  																														

$	19-Dec-2018	17:03:49.310	Init Mission	Unparsed SBE41 Message						S>tswait=2  																														

$	19-Dec-2018	17:03:50.319	Init Mission	Unparsed SBE41 Message						S>autobinavg=n  																														

$	19-Dec-2018	17:03:50.755	Init Mission	Unparsed SBE41 Message						S>top_bin_interval=2  																														

$	19-Dec-2018	17:03:51.244	Init Mission	Unparsed SBE41 Message						S>top_bin_size=2  																														

$	19-Dec-2018	17:03:51.762	Init Mission	Unparsed SBE41 Message						S>top_bin_max=10  																														

$	19-Dec-2018	17:03:52.279	Init Mission	Unparsed SBE41 Message						S>middle_bin_interval=2  																														

$	19-Dec-2018	17:04:24.943	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	29.925000	120.500000																																

$	19-Dec-2018	17:04:25.054	Init Mission	Starting valve open

$	19-Dec-2018	17:04:25.261	Init Mission	Bellows inside limits

$	19-Dec-2018	17:03:52.770	Init Mission	Unparsed SBE41 Message						S>middle_bin_size=2  																														

$	19-Dec-2018	17:03:53.272	Init Mission	Unparsed SBE41 Message						S>middle_bin_max=20  																														

$	19-Dec-2018	17:03:53.781	Init Mission	Unparsed SBE41 Message						S>bottom_bin_interval=2  																														

$	19-Dec-2018	17:03:54.271	Init Mission	Unparsed SBE41 Message						S>bottom_bin_size=2  																														

$	19-Dec-2018	17:03:54.784	Init Mission	Unparsed SBE41 Message						S>includetransitionbin=n  																														

$	19-Dec-2018	17:03:55.263	Init Mission	Unparsed SBE41 Message						S>includenbin=y  																														

$	19-Dec-2018	17:03:58.365	Init Mission	Optode Message																												!#  								

$	19-Dec-2018	17:03:59.371	Init Mission	Optode Message																												#  								

$	19-Dec-2018	17:04:00.378	Init Mission	Optode Message																												#  								

$	19-Dec-2018	17:04:26.307	Init Mission	MSC: RX: 

$	19-Dec-2018	17:04:26.506	Init Mission	MSC: RX: 

$	19-Dec-2018	17:04:26.608	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	19-Dec-2018	17:04:26.711	Init Mission	MSC: RX:   MBARI Serial Number : 0777 

$	19-Dec-2018	17:04:26.813	Init Mission	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	19-Dec-2018	17:04:26.818	Init Mission	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	19-Dec-2018	17:04:26.922	Init Mission	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	19-Dec-2018	17:04:27.330	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	134.346470	29.925000	120.500000																																

$	19-Dec-2018	17:04:28.746	Init Mission	Increasing bellows position		135.153525																																		

$	19-Dec-2018	17:04:30.958	Init Mission	Increasing bellows position		135.478571																																		

$	19-Dec-2018	17:04:33.169	Init Mission	Increasing bellows position		135.843292																																		

$	19-Dec-2018	17:04:35.379	Init Mission	Increasing bellows position		136.099830																																		

$	19-Dec-2018	17:04:37.590	Init Mission	Increasing bellows position		136.280097																																		

$	19-Dec-2018	17:04:39.800	Init Mission	Increasing bellows position		136.410400																																		

$	19-Dec-2018	17:04:42.013	Init Mission	Increasing bellows position		136.391230																																		

$	19-Dec-2018	17:04:44.223	Init Mission	Increasing bellows position		136.446156																																		

$	19-Dec-2018	17:04:46.434	Init Mission	Increasing bellows position		136.474758																																		

$	19-Dec-2018	17:04:48.644	Init Mission	Increasing bellows position		136.492498																																		

$	19-Dec-2018	17:04:51.257	Init Mission	Decreasing bellows position		136.541285																																		

$	19-Dec-2018	17:04:53.467	Init Mission	Decreasing bellows position		136.577174																																		

$	19-Dec-2018	17:04:55.678	Init Mission	Decreasing bellows position		137.248009																																		

$	19-Dec-2018	17:04:57.888	Init Mission	Decreasing bellows position		137.245029																																		

$	19-Dec-2018	17:05:00.100	Init Mission	Decreasing bellows position		137.251079																																		

$	19-Dec-2018	17:05:02.310	Init Mission	Decreasing bellows position		137.274109																																		

$	19-Dec-2018	17:05:04.521	Init Mission	Decreasing bellows position		137.273148																																		

$	19-Dec-2018	17:05:06.731	Init Mission	Decreasing bellows position		137.270592																																		

$	19-Dec-2018	17:05:08.942	Init Mission	Decreasing bellows position		137.278281																																		

$	19-Dec-2018	17:05:11.162	Init Mission	Decreasing bellows position		137.289912																																		

$	19-Dec-2018	17:05:13.173	Init Mission	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	19-Dec-2018	17:05:13.272	Init Mission	Radiometer Message																																	Firmware version: 5.1ent: SATFI4 			

$	19-Dec-2018	17:05:13.478	Init Mission	Radiometer Message																																	S/N: 0287 			

$	19-Dec-2018	17:05:13.491	Init Mission	Radiometer Message																																	Reset Source: Power 			

$	19-Dec-2018	17:05:13.599	Init Mission	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	19-Dec-2018	17:05:13.707	Init Mission	Radiometer Message																																	Initializing system. Please wait... 			

$	19-Dec-2018	17:05:13.821	Init Mission	MSC: RX:   CF Card: Size=256614400 Avail=98.98% 

$	19-Dec-2018	17:05:14.023	Init Mission	MSC: RX:   CF2 Power Up  (GMT): Mon Feb  6 23:29:39 2012 

$	19-Dec-2018	17:05:14.028	Init Mission	MSC: RX:   CF2 RTC Time  (GMT): Mon Feb  6 23:29:43 2012 

$	19-Dec-2018	17:05:14.229	Init Mission	MSC: RX:   Adjusted Local Time: Mon Feb  6 15:29:43 2012 

$	19-Dec-2018	17:05:14.331	Init Mission	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	19-Dec-2018	17:05:14.337	Init Mission	MSC: RX:   RTC delta (CF2 - DS3234) : -1.00 secs. 

$	19-Dec-2018	17:05:14.538	Init Mission	MSC: RX:   System Batt Voltage = 11.760 

$	19-Dec-2018	17:05:14.641	Init Mission	MSC: RX:   System Load Current = 2.62e-02 

$	19-Dec-2018	17:05:14.743	Init Mission	MSC: RX:   Housing Temperature = +20.77C = +69.39F 

$	19-Dec-2018	17:05:14.846	Init Mission	MSC: RX:   Housing    Humidity =  55.8%  =  11.6C (DP) 

$	19-Dec-2018	17:05:15.053	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	137.289375	29.925000	120.500000																																

$	19-Dec-2018	17:05:15.167	Init Mission	MSC: RX:   Power Cycle   Count = 205 

$	19-Dec-2018	17:05:15.174	Init Mission	MSC: RX:   System Reset  Count = 209 

$	19-Dec-2018	17:05:15.276	Init Mission	MSC: RX:   System Error  Count = 92 

$	19-Dec-2018	17:05:15.476	Init Mission	MSC: RX:   Last System   Error = -110 

$	19-Dec-2018	17:05:15.579	Init Mission	MSC: RX:   Last Error     Time = Mon Feb  6 04:46:15 2012 

$	19-Dec-2018	17:05:15.683	Init Mission	MSC: RX:   ISUS Error    Count = 1 

$	19-Dec-2018	17:05:15.785	Init Mission	MSC: RX:   Last ISUS     Error = -202 

$	19-Dec-2018	17:05:15.888	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	19-Dec-2018	17:05:15.990	Init Mission	MSC: RX:   DURA Error    Count = 0 

$	19-Dec-2018	17:05:16.093	Init Mission	MSC: RX:   Last DURA     Error = 0 

$	19-Dec-2018	17:05:16.195	Init Mission	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	19-Dec-2018	17:05:16.202	Init Mission	MSC: RX:   Fiberlite  Odometer = 100:15:06 = 360906 secs 

$	19-Dec-2018	17:05:16.402	Init Mission	MSC: RX:   Fiberlite    Cycles = 318 

$	19-Dec-2018	17:05:16.505	Init Mission	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	19-Dec-2018	17:05:16.607	Init Mission	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	19-Dec-2018	17:05:16.613	Init Mission	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	19-Dec-2018	17:05:17.014	Init Mission	PTH Message														776.037109	20.583333	55.779022	21.737000																			

$	19-Dec-2018	17:05:17.218	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	137.269422	29.800000	171.500000																																

$	19-Dec-2018	17:05:17.330	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	17:05:17.334	Init Mission	Sending ds command

$	19-Dec-2018	17:05:17.539	Init Mission	MSC: RX:   There are 98 records in the error file! 

$	19-Dec-2018	17:05:17.646	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	19-Dec-2018	17:05:17.652	Init Mission	MSC: RX:   Auto Shutdown in 10 hours at: Tue Feb  7 09:29:44 2012 

$	19-Dec-2018	17:05:17.856	Init Mission	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	19-Dec-2018	17:05:17.959	Init Mission	Radiometer Message																																	Autonomous operation enabled. 			

$	19-Dec-2018	17:04:14.925	Init Mission	SBE41 Message						   -2.76  	-2.760000	-0.000024	-0.000000	0.920000	0.460000	0.000000	3.000000																							

$	19-Dec-2018	17:05:18.405	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.297302	29.800000	171.500000																																

$	19-Dec-2018	17:05:18.517	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	17:05:18.823	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.289450	29.800000	171.500000																																

$	19-Dec-2018	17:05:19.518	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	17:05:17.537	Init Mission	Unparsed SBE41 Message						S>ds  																														

$	19-Dec-2018	17:05:17.644	Init Mission	Unparsed SBE41 Message						firmware compilation date: 18 December 2007 09:20  																														

$	19-Dec-2018	17:05:17.645	Init Mission	Unparsed SBE41 Message						stop profile when pressure is less than = 1.0 decibars  																														

$	19-Dec-2018	17:05:17.750	Init Mission	Unparsed SBE41 Message						automatic bin averaging at end of profile disabled  																														

$	19-Dec-2018	17:05:17.751	Init Mission	Unparsed SBE41 Message						number of samples = 242  																														

$	19-Dec-2018	17:05:17.752	Init Mission	Unparsed SBE41 Message						number of bins = 14  																														

$	19-Dec-2018	17:05:17.855	Init Mission	Unparsed SBE41 Message						top bin interval = 2  																														

$	19-Dec-2018	17:05:20.549	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.310594	29.800000	171.500000																																

$	19-Dec-2018	17:05:20.660	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	17:05:17.959	Init Mission	Unparsed SBE41 Message						top bin size = 2  																														

$	19-Dec-2018	17:05:18.068	Init Mission	Unparsed SBE41 Message						top bin max = 10  																														

$	19-Dec-2018	17:05:18.069	Init Mission	Unparsed SBE41 Message						middle bin interval = 2  																														

$	19-Dec-2018	17:05:18.089	Init Mission	Unparsed SBE41 Message						middle bin size = 2  																														

$	19-Dec-2018	17:05:18.090	Init Mission	Unparsed SBE41 Message						middle bin max = 20  																														

$	19-Dec-2018	17:05:18.091	Init Mission	Unparsed SBE41 Message						bottom bin interval = 2  																														

$	19-Dec-2018	17:05:18.091	Init Mission	Unparsed SBE41 Message						bottom bin size = 2  																														

$	19-Dec-2018	17:05:18.092	Init Mission	Unparsed SBE41 Message						do not include two transition bins  																														

$	19-Dec-2018	17:05:18.093	Init Mission	Unparsed SBE41 Message						include samples per bin  																														

$	19-Dec-2018	17:05:18.201	Init Mission	Unparsed SBE41 Message						pumped take sample wait time = 2 sec  																														

$	19-Dec-2018	17:05:18.202	Init Mission	Unparsed SBE41 Message						real-time output is PTS  																														

$	19-Dec-2018	17:05:22.257	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.306653	29.800000	171.500000																																

$	19-Dec-2018	17:05:22.369	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	17:05:22.575	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.315728	29.800000	171.500000																																

$	19-Dec-2018	17:05:23.369	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	17:05:23.374	Init Mission	Sending dc command

$	19-Dec-2018	17:05:23.781	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.321398	29.800000	171.500000																																

$	19-Dec-2018	17:05:24.370	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	17:05:23.576	Init Mission	Unparsed SBE41 Message						S>dc  																														

$	19-Dec-2018	17:05:23.578	Init Mission	Unparsed SBE41 Message						temperature:  15-mar-14  																														

$	19-Dec-2018	17:05:23.604	Init Mission	Unparsed SBE41 Message						    TA0 =  3.536242e-05  																														

$	19-Dec-2018	17:05:23.641	Init Mission	Unparsed SBE41 Message						    TA1 =  2.674251e-04  																														

$	19-Dec-2018	17:05:23.677	Init Mission	Unparsed SBE41 Message						    TA2 = -1.901062e-06  																														

$	19-Dec-2018	17:05:23.712	Init Mission	Unparsed SBE41 Message						    TA3 =  1.365250e-07  																														

$	19-Dec-2018	17:05:23.749	Init Mission	Unparsed SBE41 Message						conductivity:  15-mar-14  																														

$	19-Dec-2018	17:05:23.892	Init Mission	Unparsed SBE41 Message						    G = -9.858232e-01  																														

$	19-Dec-2018	17:05:23.893	Init Mission	Unparsed SBE41 Message						    H =  1.476071e-01  																														

$	19-Dec-2018	17:05:23.894	Init Mission	Unparsed SBE41 Message						    I = -3.292498e-04  																														

$	19-Dec-2018	17:05:23.894	Init Mission	Unparsed SBE41 Message						    J =  4.505543e-05  																														

$	19-Dec-2018	17:05:23.922	Init Mission	Unparsed SBE41 Message						    CPCOR = -9.570001e-08  																														

$	19-Dec-2018	17:05:23.960	Init Mission	Unparsed SBE41 Message						    CTCOR =  3.250000e-06  																														

$	19-Dec-2018	17:05:23.998	Init Mission	Unparsed SBE41 Message						    WBOTC = -3.218098e-07  																														

$	19-Dec-2018	17:05:24.082	Init Mission	Unparsed SBE41 Message						pressure S/N = 4004719, range = 2900 psia:  10-mar-14  																														

$	19-Dec-2018	17:05:26.439	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.314059	29.800000	171.500000																																

$	19-Dec-2018	17:05:26.552	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	17:05:24.117	Init Mission	Unparsed SBE41 Message						    PA0 =  1.629284e-01  																														

$	19-Dec-2018	17:05:24.153	Init Mission	Unparsed SBE41 Message						    PA1 =  1.404717e-01  																														

$	19-Dec-2018	17:05:24.190	Init Mission	Unparsed SBE41 Message						    PA2 = -3.503310e-08  																														

$	19-Dec-2018	17:05:24.229	Init Mission	Unparsed SBE41 Message						    PTCA0 =  2.758681e+01  																														

$	19-Dec-2018	17:05:24.267	Init Mission	Unparsed SBE41 Message						    PTCA1 =  2.201518e-02  																														

$	19-Dec-2018	17:05:24.306	Init Mission	Unparsed SBE41 Message						    PTCA2 =  1.374282e-03  																														

$	19-Dec-2018	17:05:24.345	Init Mission	Unparsed SBE41 Message						    PTCB0 =  2.510888e+01  																														

$	19-Dec-2018	17:05:24.472	Init Mission	Unparsed SBE41 Message						    PTCB1 =  1.175000e-03  																														

$	19-Dec-2018	17:05:24.492	Init Mission	Unparsed SBE41 Message						    PTCB2 =  0.000000e+00  																														

$	19-Dec-2018	17:05:24.493	Init Mission	Unparsed SBE41 Message						    PTHA0 = -7.442904e+01  																														

$	19-Dec-2018	17:05:24.591	Init Mission	Unparsed SBE41 Message						    PTHA1 =  4.994783e-02  																														

$	19-Dec-2018	17:05:24.592	Init Mission	Unparsed SBE41 Message						    PTHA2 = -3.966033e-07  																														

$	19-Dec-2018	17:05:24.593	Init Mission	Unparsed SBE41 Message						    POFFSET =  0.000000e+00  																														

$	19-Dec-2018	17:05:28.384	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.311615	29.800000	171.500000																																

$	19-Dec-2018	17:05:28.497	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	17:05:28.703	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.323402	29.800000	171.500000																																

$	19-Dec-2018	17:05:29.700	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-2.760000	137.325630	29.800000	171.500000																																

$	19-Dec-2018	17:05:30.498	Init Mission	Sending Optode GetAll

$	19-Dec-2018	17:05:30.502	Init Mission	Sending Optode Wakeup

$	19-Dec-2018	17:05:30.471	Init Mission	SBE41 Message						   -0.08  	-0.080000	-0.005844	-0.000068	-0.893333	0.013333	0.000000	3.000000																							

$	19-Dec-2018	17:05:31.272	Init Mission	Optode Message																												%!Product Name,4330,1532,Optode Sensor  								

$	19-Dec-2018	17:05:31.304	Init Mission	Optode Message																												Product Number,4330,1532,4330  								

$	19-Dec-2018	17:05:31.336	Init Mission	Optode Message																												Serial Number,4330,1532,1532  								

$	19-Dec-2018	17:05:31.361	Init Mission	Optode Message																												SW ID,4330,1532,1940006  								

$	19-Dec-2018	17:05:31.391	Init Mission	Optode Message																												SW Version,4330,1532,4,8,1  								

$	19-Dec-2018	17:05:31.432	Init Mission	Optode Message																												Node Description,4330,1532,optode 1532  								

$	19-Dec-2018	17:05:31.450	Init Mission	Optode Message																												Owner,4330,1532,  								

$	19-Dec-2018	17:05:31.482	Init Mission	Optode Message																												Salinity[PSU],4330,1532,0.00  								

$	19-Dec-2018	17:05:31.558	Init Mission	Optode Message																												PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00  								

$	19-Dec-2018	17:05:31.583	Init Mission	Optode Message																												FoilID,4330,1532,1206E  								

$	19-Dec-2018	17:05:31.802	Init Mission	Optode Message																												FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04  								

$	19-Dec-2018	17:05:32.017	Init Mission	Optode Message																												FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	19-Dec-2018	17:05:32.100	Init Mission	Optode Message																												FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0  								

$	19-Dec-2018	17:05:35.900	Init Mission	Normal State Exit

$	19-Dec-2018	17:05:35.904	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.323588	29.800000	171.500000																																

$	19-Dec-2018	17:05:36.123	Init Profile	State Entry

$	19-Dec-2018	17:05:36.128	Init Profile	Initializing SBE 41 LPF

$	19-Dec-2018	17:05:36.337	Init Profile	Sending SBE41 stopProfile

$	19-Dec-2018	17:05:37.341	Init Profile	Resetting SBE41 with qsr

$	19-Dec-2018	17:05:37.346	Init Profile	Sending qsr command

$	19-Dec-2018	17:05:32.183	Init Profile	Optode Message																												FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0  								

$	19-Dec-2018	17:05:32.302	Init Profile	Optode Message																												SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	19-Dec-2018	17:05:32.350	Init Profile	Optode Message																												ConcCoef,4330,1532,-1.549127E+00,1.068129E+00  								

$	19-Dec-2018	17:05:32.387	Init Profile	Optode Message																												NomAirPress[hPa],4330,1532,1013.25  								

$	19-Dec-2018	17:05:32.418	Init Profile	Optode Message																												NomAirMix,4330,1532,0.20946  								

$	19-Dec-2018	17:05:32.458	Init Profile	Optode Message																												CalDataSat[Deg],4330,1532,31.61,10.06  								

$	19-Dec-2018	17:05:32.499	Init Profile	Optode Message																												CalDataAPress[hPa],4330,1532,1002.000  								

$	19-Dec-2018	17:05:32.542	Init Profile	Optode Message																												CalDataZero[Deg],4330,1532,61.907,21.413  								

$	19-Dec-2018	17:05:32.582	Init Profile	Optode Message																												Mode,4330,1532,Smart Sensor Terminal  								

$	19-Dec-2018	17:05:32.611	Init Profile	Optode Message																												Enable Sleep,4330,1532,Yes  								

$	19-Dec-2018	17:05:32.647	Init Profile	Optode Message																												Enable Polled Mode,4330,1532,Yes  								

$	19-Dec-2018	17:05:32.673	Init Profile	Optode Message																												Enable Text,4330,1532,No  								

$	19-Dec-2018	17:05:32.710	Init Profile	Optode Message																												Enable Decimalformat,4330,1532,Yes  								

$	19-Dec-2018	17:05:32.759	Init Profile	Optode Message																												Analog TempLimit[Deg.C],4330,1532,-5.00,35.00  								

$	19-Dec-2018	17:05:32.809	Init Profile	Optode Message																												Analog ConcLimit[Deg.C],4330,1532,0.00,800.00  								

$	19-Dec-2018	17:05:32.857	Init Profile	Optode Message																												Analog SatLimit[Deg.C],4330,1532,0.00,200.00  								

$	19-Dec-2018	17:05:41.546	Init Profile	Normal State Exit

$	19-Dec-2018	17:05:41.551	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.325458	29.800000	171.500000																																

$	19-Dec-2018	17:05:41.764	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.6405718

$	19-Dec-2018	17:05:41.769	Surface Ops Set Bellows	State Entry

$	19-Dec-2018	17:05:41.973	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	19-Dec-2018	17:05:32.906	Surface Ops Set Bellows	Optode Message																												Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00  								

$	19-Dec-2018	17:05:32.949	Surface Ops Set Bellows	Optode Message																												Analog Output,4330,1532,O2Concentration  								

$	19-Dec-2018	17:05:33.002	Surface Ops Set Bellows	Optode Message																												Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	19-Dec-2018	17:05:33.053	Surface Ops Set Bellows	Optode Message																												Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	19-Dec-2018	17:05:33.089	Surface Ops Set Bellows	Optode Message																												Enable AirSaturation,4330,1532,No  								

$	19-Dec-2018	17:05:33.120	Surface Ops Set Bellows	Optode Message																												Enable Rawdata,4330,1532,Yes  								

$	19-Dec-2018	17:05:33.156	Surface Ops Set Bellows	Optode Message																												Enable Temperature,4330,1532,Yes  								

$	19-Dec-2018	17:05:33.192	Surface Ops Set Bellows	Optode Message																												Enable HumidityComp,4330,1532,Yes  								

$	19-Dec-2018	17:05:33.225	Surface Ops Set Bellows	Optode Message																												Enable SVUformula,4330,1532,No  								

$	19-Dec-2018	17:05:33.256	Surface Ops Set Bellows	Optode Message																												Interval[s],4330,1532,30.000  								

$	19-Dec-2018	17:05:33.278	Surface Ops Set Bellows	Optode Message																												Location,4330,1532,  								

$	19-Dec-2018	17:05:33.328	Surface Ops Set Bellows	Optode Message																												Geographic Position,4330,1532,60.323605,5.37225  								

$	19-Dec-2018	17:05:33.360	Surface Ops Set Bellows	Optode Message																												Vertical Position,4330,1532,  								

$	19-Dec-2018	17:05:33.383	Surface Ops Set Bellows	Optode Message																												Reference,4330,1532,  								

$	19-Dec-2018	17:05:33.386	Surface Ops Set Bellows	Optode Message																												#  								

$	19-Dec-2018	17:05:44.178	Surface Ops Set Bellows	Normal State Exit

$	19-Dec-2018	17:05:44.183	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.342431	29.800000	171.500000																																

$	19-Dec-2018	17:05:44.397	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.6271966

$	19-Dec-2018	17:05:44.404	Pre-Mission Delay	State Entry

$	19-Dec-2018	17:05:33.471	Pre-Mission Delay	SBE41 Message						   -0.09  	-0.090000	-0.080000	-0.000000	0.003333	0.001667	-0.000000	3.000000																							

$	19-Dec-2018	17:05:44.936	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.342498	29.800000	171.500000																																

$	19-Dec-2018	17:05:36.479	Pre-Mission Delay	SBE41 Message						   -0.85  	-0.850000	-0.080028	-0.000000	0.253333	0.128333	0.000000	3.000000																							

$	19-Dec-2018	17:05:39.546	Pre-Mission Delay	SBE41 Message						   -0.07  	-0.070000	-0.081870	-0.000021	-0.260000	-0.003333	0.000002	3.000000																							

$	19-Dec-2018	17:05:45.858	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.322053	29.800000	171.500000																																

$	19-Dec-2018	17:05:46.608	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.341335	29.800000	171.500000																																

$	19-Dec-2018	17:05:43.174	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	19-Dec-2018	17:05:47.725	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.356989	29.800000	171.500000																																

$	19-Dec-2018	17:05:45.532	Pre-Mission Delay	SBE41 Message						   -1.10  	-1.100000	-0.099501	-0.000155	0.343333	0.041667	0.000026	3.000000																							

$	19-Dec-2018	17:05:48.529	Pre-Mission Delay	SBE41 Message						    0.02  	0.020000	-0.162810	-0.000125	-0.373333	-0.015000	0.000128	3.000000																							

$	19-Dec-2018	17:05:48.759	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.020000	137.329653	29.800000	171.500000																																

$	19-Dec-2018	17:05:49.606	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.020000	137.355521	29.800000	171.500000																																

$	19-Dec-2018	17:05:50.606	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.020000	137.326241	29.800000	171.500000																																

$	19-Dec-2018	17:05:51.606	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.020000	137.357332	29.800000	171.500000																																

$	19-Dec-2018	17:05:51.471	Pre-Mission Delay	SBE41 Message						   -0.08  	-0.080000	-0.280177	0.001732	0.033333	-0.170000	0.000370	3.000000																							

$	19-Dec-2018	17:05:52.730	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.355201	29.800000	171.500000																																

$	19-Dec-2018	17:05:53.606	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.352698	29.800000	171.500000																																

$	19-Dec-2018	17:05:54.607	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.347482	29.800000	171.500000																																

$	19-Dec-2018	17:05:55.004	Pre-Mission Delay	State Timed Out

$	19-Dec-2018	17:05:55.013	Surface Ops	State Entry

$	19-Dec-2018	17:05:55.119	Surface Ops	Powering up Iridium Modem

$	19-Dec-2018	17:06:05.001	Surface Ops	Starting valve close

$	19-Dec-2018	17:06:05.005	Surface Ops	Sending SBDD2 cmd

$	19-Dec-2018	17:05:54.470	Surface Ops	SBE41 Message						   -0.08  	-0.080000	-0.406240	0.007741	0.000000	0.016667	0.000756	3.000000																							

$	19-Dec-2018	17:06:05.539	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.358733	29.800000	171.500000																																

$	19-Dec-2018	17:06:05.652	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.5301106

$	19-Dec-2018	17:05:57.471	Surface Ops	SBE41 Message						   -0.08  	-0.080000	-0.472387	0.017894	0.000000	0.000000	0.001204	3.000000																							

$	19-Dec-2018	17:05:58.235	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:05.988	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:05:58.237	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:06.201	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:05:59.235	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:06.417	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:05:59.237	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:06.630	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:00.237	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:06.843	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:00.239	Surface Ops	A3LA Message																																			0  	

$	19-Dec-2018	17:06:07.054	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	19-Dec-2018	17:06:07.263	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.355886	29.800000	171.500000																																

$	19-Dec-2018	17:06:07.375	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:01.7174822

$	19-Dec-2018	17:06:00.240	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:07.589	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:00.242	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:07.800	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:00.470	Surface Ops	SBE41 Message						   -0.08  	-0.080000	-0.431377	0.028111	0.000000	0.000000	0.001576	3.000000																							

$	19-Dec-2018	17:06:01.236	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:08.137	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:01.245	Surface Ops	A3LA Message																																			300125060561320  	

$	19-Dec-2018	17:06:08.349	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->300125060561320  <--  

$	19-Dec-2018	17:06:01.247	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:08.562	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:01.249	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:08.774	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:02.238	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:08.985	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:02.239	Surface Ops	A3LA Message																																			0  	

$	19-Dec-2018	17:06:09.199	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	19-Dec-2018	17:06:02.241	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:09.414	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:02.243	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:09.627	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:03.238	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:09.839	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:03.240	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:10.051	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:03.471	Surface Ops	SBE41 Message						   -0.09  	-0.090000	-0.298832	0.031309	0.003333	0.001667	0.001761	3.000000																							

$	19-Dec-2018	17:06:10.386	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.384154	29.800000	171.500000																																

$	19-Dec-2018	17:06:10.499	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.1185855

$	19-Dec-2018	17:06:04.239	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:10.712	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:04.250	Surface Ops	A3LA Message																																			8988169234000597401  	

$	19-Dec-2018	17:06:10.975	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->8988169234000597401  <--  

$	19-Dec-2018	17:06:04.251	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:11.188	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:04.253	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:11.400	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:05.210	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:11.611	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:05.210	Surface Ops	A3LA Message																																			0  	

$	19-Dec-2018	17:06:11.824	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	19-Dec-2018	17:06:05.210	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	17:06:12.036	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	17:06:05.211	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	17:06:12.253	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	17:06:06.734	Surface Ops	SBE41 Message						   -0.31  	-0.310000	-0.162978	0.021766	0.073333	0.038333	0.001761	3.000000																							

$	19-Dec-2018	17:06:09.731	Surface Ops	SBE41 Message						   -1.24  	-1.240000	-0.095006	0.001376	0.310000	0.191667	0.001671	3.000000																							

$	19-Dec-2018	17:06:12.808	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-1.240000	137.376584	29.800000	171.500000																																

$	19-Dec-2018	17:06:12.920	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.4139667

$	19-Dec-2018	17:06:12.610	Surface Ops	SBE41 Message						   -1.94  	-1.940000	-0.088775	-0.019881	0.233333	0.271667	0.001573	3.000000																							

$	19-Dec-2018	17:06:13.251	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-1.940000	137.370177	29.800000	171.500000																																

$	19-Dec-2018	17:06:14.129	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-1.940000	137.375399	29.800000	171.500000																																

$	19-Dec-2018	17:06:15.129	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-1.940000	137.366064	29.800000	171.500000																																

$	19-Dec-2018	17:06:15.578	Surface Ops	SBE41 Message						   -0.08  	-0.080000	-0.137340	-0.031708	-0.620000	-0.193333	0.001535	3.000000																							

$	19-Dec-2018	17:06:16.154	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.378424	29.800000	171.500000																																

$	19-Dec-2018	17:06:17.128	Surface Ops	PTH Message														775.427490	21.141667	55.290741	21.972952																			

$	19-Dec-2018	17:06:17.331	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.358315	NaN	165.000000																																

$	19-Dec-2018	17:06:18.127	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.381501	NaN	165.000000																																

$	19-Dec-2018	17:06:18.579	Surface Ops	SBE41 Message						   -0.09  	-0.090000	-0.298015	-0.029930	0.003333	-0.308333	0.001693	3.000000																							

$	19-Dec-2018	17:06:19.156	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.375355	NaN	165.000000																																

$	19-Dec-2018	17:06:20.128	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.381174	NaN	165.000000																																

$	19-Dec-2018	17:06:21.128	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.383029	NaN	165.000000																																

$	19-Dec-2018	17:06:21.579	Surface Ops	SBE41 Message						   -0.08  	-0.080000	-0.601405	-0.014701	-0.003333	0.000000	0.002214	3.000000																							

$	19-Dec-2018	17:06:22.155	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.384243	NaN	165.000000																																

$	19-Dec-2018	17:06:23.129	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.374498	NaN	165.000000																																

$	19-Dec-2018	17:06:24.129	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.387112	NaN	165.000000																																

$	19-Dec-2018	17:06:24.579	Surface Ops	SBE41 Message						   -0.07  	-0.070000	-0.891723	0.012774	-0.003333	-0.003333	0.003062	3.000000																							

$	19-Dec-2018	17:06:25.255	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.383282	NaN	165.000000																																

$	19-Dec-2018	17:06:26.130	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.372561	NaN	165.000000																																

$	19-Dec-2018	17:06:27.130	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.384102	NaN	165.000000																																

$	19-Dec-2018	17:06:27.579	Surface Ops	SBE41 Message						   -0.07  	-0.070000	-0.909106	0.046017	0.000000	-0.001667	0.003878	3.000000																							

$	19-Dec-2018	17:06:28.157	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.388885	NaN	165.000000																																

$	19-Dec-2018	17:06:29.131	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.386039	NaN	165.000000																																

$	19-Dec-2018	17:06:30.131	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.070000	137.403123	NaN	165.000000																																

$	19-Dec-2018	17:06:30.579	Surface Ops	SBE41 Message						   -0.10  	-0.100000	-0.626313	0.068485	0.010000	0.005000	0.004289	3.000000																							

$	19-Dec-2018	17:06:31.256	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	137.398466	NaN	165.000000																																

$	19-Dec-2018	17:06:32.131	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	137.394518	NaN	165.000000																																

$	19-Dec-2018	17:06:33.131	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.100000	137.384377	NaN	165.000000																																

$	19-Dec-2018	17:06:33.580	Surface Ops	SBE41 Message						   -0.08  	-0.080000	-0.299983	0.062495	-0.006667	0.001667	0.004260	3.000000																							

$	19-Dec-2018	17:06:34.157	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.386717	NaN	165.000000																																

$	19-Dec-2018	17:06:35.131	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.388006	NaN	165.000000																																

$	19-Dec-2018	17:06:36.132	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.080000	137.390651	NaN	165.000000																																

$	19-Dec-2018	17:06:36.580	Surface Ops	SBE41 Message						   -0.09  	-0.090000	-0.126585	0.025889	0.003333	-0.001667	0.004002	3.000000																							

$	19-Dec-2018	17:06:37.056	Surface Ops	Processing Console Command: $go

$	19-Dec-2018	17:06:37.362	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.427144	NaN	165.000000																																

$	19-Dec-2018	17:06:38.132	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.411222	NaN	165.000000																																

$	19-Dec-2018	17:06:39.132	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	-0.090000	137.405463	NaN	165.000000																																

$	19-Dec-2018	17:06:39.929	Surface Ops	Powering up 4330 Optode

$	19-Dec-2018	17:06:41.434	Surface Ops	Sending Optode Wakeup

$	19-Dec-2018	17:06:45.440	Surface Ops	Powering up OCR504

$	19-Dec-2018	17:06:45.542	Surface Ops	Closing old .eng file: \SD\data\cpf001.000.2018-12-19T16-59-47.eng
