$	Date	Time	State	Comment	Pressure	Bel Pos	Batt Volt	Batt Amps	CTD Temp	CTD Sal	Raw Press	LPF Press	LPF Vel	Diff Vel	Diff 2 Vel	Slope of LPF Press.	CTD Sample Period	LPS331 Press	LPS311 Temp	SHT21 Humid	SHT21 Temp	PID SP	PID PV	PID Y1	PID Y2	PID I	PID v	PID u	PID uCPS	PID h	FLBB	Topt	Tphase	Rphase	NO3	pH	OCR	GPS	Irid Modem	
$	19-Dec-2018	23:37:34.803	SM Not Running	Reset Controller Status Register Value = 65792

$	19-Dec-2018	23:37:34.807	SM Not Running	File Name = \SD\data\cpf001.000.2018-12-19T23-37-33.eng

$	19-Dec-2018	23:37:34.813	SM Not Running	Volume Total Size:     7939817472

$	19-Dec-2018	23:37:34.817	SM Not Running	Volume Free Space:     7864090624

$	19-Dec-2018	23:37:34.821	SM Not Running	PlatVel PID K = 80

$	19-Dec-2018	23:37:34.825	SM Not Running	PlatVel PID Ti = 50000

$	19-Dec-2018	23:37:34.829	SM Not Running	PlatVel PID Td = 10

$	19-Dec-2018	23:37:34.833	SM Not Running	PlatVel PID Tf = 10

$	19-Dec-2018	23:37:34.837	SM Not Running	PlatVel PID Tt = 100

$	19-Dec-2018	23:37:34.841	SM Not Running	PlatVel PID B = 1

$	19-Dec-2018	23:37:34.846	SM Not Running	PlatVel PID uLow = -50

$	19-Dec-2018	23:37:34.850	SM Not Running	PlatVel PID uHigh = 50

$	19-Dec-2018	23:37:34.854	SM Not Running	PlatVel PID h = 3

$	19-Dec-2018	23:37:34.858	SM Not Running	Engr Logger Initialized

$	19-Dec-2018	23:37:35.361	SM Not Running	Initializing Bluetooth Console

$	19-Dec-2018	23:37:36.366	SM Not Running	Initializing GPS and synching time

$	19-Dec-2018	23:37:37.001	SM Not Running	Creating Mission

$	19-Dec-2018	23:37:37.104	SM Not Running	Maximum number of profiles = 10

$	19-Dec-2018	23:37:37.208	SM Not Running	Mission Timeout = 24:00:00   Mission Start Time: 12/19/2018 23:37:37

$	19-Dec-2018	23:37:37.313	SM Not Running	Recovery mode = True

$	19-Dec-2018	23:37:37.419	SM Not Running	Park Sample Period = 00:01:00

$	19-Dec-2018	23:37:37.526	SM Not Running	Descend table 0 Pressure, PV, Park Time, sample list: 100, -0.200, 00:04:00, 7

$	19-Dec-2018	23:37:37.633	SM Not Running	Ascend table 0 Pressure, PV, Park Time, sample list: 100, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:37.740	SM Not Running	Ascend table 1 Pressure, PV, Park Time, sample list: 95, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:37.847	SM Not Running	Ascend table 2 Pressure, PV, Park Time, sample list: 90, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:37.954	SM Not Running	Ascend table 3 Pressure, PV, Park Time, sample list: 85, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.071	SM Not Running	Ascend table 4 Pressure, PV, Park Time, sample list: 80, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.197	SM Not Running	Ascend table 5 Pressure, PV, Park Time, sample list: 75, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.305	SM Not Running	Ascend table 6 Pressure, PV, Park Time, sample list: 70, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.411	SM Not Running	Ascend table 7 Pressure, PV, Park Time, sample list: 65, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.518	SM Not Running	Ascend table 8 Pressure, PV, Park Time, sample list: 60, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.626	SM Not Running	Ascend table 9 Pressure, PV, Park Time, sample list: 55, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.733	SM Not Running	Ascend table 10 Pressure, PV, Park Time, sample list: 50, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.842	SM Not Running	Ascend table 11 Pressure, PV, Park Time, sample list: 45, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:38.949	SM Not Running	Ascend table 12 Pressure, PV, Park Time, sample list: 40, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.056	SM Not Running	Ascend table 13 Pressure, PV, Park Time, sample list: 35, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.163	SM Not Running	Ascend table 14 Pressure, PV, Park Time, sample list: 30, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.270	SM Not Running	Ascend table 15 Pressure, PV, Park Time, sample list: 25, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.377	SM Not Running	Ascend table 16 Pressure, PV, Park Time, sample list: 20, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.484	SM Not Running	Ascend table 17 Pressure, PV, Park Time, sample list: 18, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.596	SM Not Running	Ascend table 18 Pressure, PV, Park Time, sample list: 16, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.703	SM Not Running	Ascend table 19 Pressure, PV, Park Time, sample list: 14, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.810	SM Not Running	Ascend table 20 Pressure, PV, Park Time, sample list: 12, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:39.917	SM Not Running	Ascend table 21 Pressure, PV, Park Time, sample list: 10, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:40.026	SM Not Running	Ascend table 22 Pressure, PV, Park Time, sample list: 8, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:40.132	SM Not Running	Ascend table 23 Pressure, PV, Park Time, sample list: 6, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:40.243	SM Not Running	Ascend table 24 Pressure, PV, Park Time, sample list: 4, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:40.350	SM Not Running	Ascend table 25 Pressure, PV, Park Time, sample list: 2, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:40.459	SM Not Running	Ascend table 26 Pressure, PV, Park Time, sample list: 0, 0.100, 00:00:00, 7

$	19-Dec-2018	23:37:40.562	SM Not Running	Initializing Buoyancy Engine

$	19-Dec-2018	23:37:40.665	SM Not Running	Starting valve close

$	19-Dec-2018	23:37:40.768	Init Mission	State Entry

$	19-Dec-2018	23:37:40.773	Init Mission	Initializing FLBB

$	19-Dec-2018	23:37:45.378	Init Mission	Sending FLBB stop command

$	19-Dec-2018	23:37:46.981	Init Mission	Sending FLBB pkt command: $pkt 1  

$	19-Dec-2018	23:37:48.086	Init Mission	Sending FLBB ave command: $ave 10  

$	19-Dec-2018	23:37:50.093	Init Mission	Initializing Iridium Modem

$	19-Dec-2018	23:37:59.698	Init Mission	Initializing SBE41

$	19-Dec-2018	23:38:05.308	Init Mission	Sending SBE41 stopProfile

$	19-Dec-2018	23:38:06.313	Init Mission	pcutoff=1 

$	19-Dec-2018	23:38:07.318	Init Mission	Sending outputPTSyes

$	19-Dec-2018	23:38:08.323	Init Mission	Sending tsWait

$	19-Dec-2018	23:38:09.329	Init Mission	Sending 11 bin setup commands

$	19-Dec-2018	23:38:15.855	Init Mission	Initializing Optode

$	19-Dec-2018	23:38:16.457	Init Mission	Sending Optode Wakeup

$	19-Dec-2018	23:38:21.464	Init Mission	Initializing Pressure, Temperature, Humidity sensor

$	19-Dec-2018	23:38:21.971	Init Mission	Set can pressure resolution to low

$	19-Dec-2018	23:38:22.073	Init Mission	Set can pressure active

$	19-Dec-2018	23:38:22.077	Init Mission	PTH Message														784.618408	21.733333	54.977936	22.852410																			

$	19-Dec-2018	23:38:22.278	Init Mission	Initializing MSC

$	19-Dec-2018	23:38:22.881	Init Mission	MSC: OUT: INIT

$	19-Dec-2018	23:38:22.984	Init Mission	Initializing Radiometer 1

$	19-Dec-2018	23:38:23.496	Init Mission	Powering down OCR504

$	19-Dec-2018	23:38:28.501	Init Mission	Powering up OCR504

$	19-Dec-2018	23:38:33.509	Init Mission	FLBB Message																											/99/99,99:99:99,695,2296,700,4130,541  									

$	19-Dec-2018	23:37:53.701	Init Mission	A3LA Message																																			AT&D0   	

$	19-Dec-2018	23:37:53.703	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:37:54.701	Init Mission	A3LA Message																																			AT&K0   	

$	19-Dec-2018	23:37:54.703	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:37:55.704	Init Mission	A3LA Message																																			AT+SBDD2   	

$	19-Dec-2018	23:37:55.706	Init Mission	A3LA Message																																			0  	

$	19-Dec-2018	23:37:55.707	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	23:37:55.709	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:37:56.709	Init Mission	A3LA Message																																			AT+GSN    	

$	19-Dec-2018	23:37:56.718	Init Mission	A3LA Message																																			300125060561320  	

$	19-Dec-2018	23:37:56.719	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	23:37:56.722	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:37:58.117	Init Mission	A3LA Message																																			AT+SBDC   	

$	19-Dec-2018	23:37:58.118	Init Mission	A3LA Message																																			0  	

$	19-Dec-2018	23:37:58.119	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	23:38:35.346	Init Mission	PTH Message														784.618408	21.750000	55.031342	22.841685																			

$	19-Dec-2018	23:38:35.550	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	28.925000	118.500000																																

$	19-Dec-2018	23:38:35.661	Init Mission	Starting valve close

$	19-Dec-2018	23:38:37.665	Init Mission	Closed valve isValveOpen = false

$	19-Dec-2018	23:38:37.764	Init Mission	Starting valve open

$	19-Dec-2018	23:38:39.963	Init Mission	Opened valve isValveOpen = true

$	19-Dec-2018	23:38:39.969	Init Mission	Starting valve close

$	19-Dec-2018	23:38:42.071	Init Mission	Closed valve isValveOpen = false

$	19-Dec-2018	23:37:58.121	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:37:58.710	Init Mission	A3LA Message																																			ATEn=0   	

$	19-Dec-2018	23:37:58.712	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:37:59.865	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	23:37:59.876	Init Mission	A3LA Message																																			8988169234000597401  	

$	19-Dec-2018	23:37:59.877	Init Mission	A3LA Message																																			  	

$	19-Dec-2018	23:37:59.879	Init Mission	A3LA Message																																			OK  	

$	19-Dec-2018	23:38:05.424	Init Mission	Unparsed SBE41 Message						S>stopprofile  																														

$	19-Dec-2018	23:38:06.426	Init Mission	Unparsed SBE41 Message						?cmd S>pcutoff=1  																														

$	19-Dec-2018	23:38:07.433	Init Mission	Unparsed SBE41 Message						S>outputpts=y  																														

$	19-Dec-2018	23:38:08.436	Init Mission	Unparsed SBE41 Message						S>tswait=2  																														

$	19-Dec-2018	23:38:09.446	Init Mission	Unparsed SBE41 Message						S>autobinavg=n  																														

$	19-Dec-2018	23:38:09.881	Init Mission	Unparsed SBE41 Message						S>top_bin_interval=2  																														

$	19-Dec-2018	23:38:10.372	Init Mission	Unparsed SBE41 Message						S>top_bin_size=2  																														

$	19-Dec-2018	23:38:10.890	Init Mission	Unparsed SBE41 Message						S>top_bin_max=10  																														

$	19-Dec-2018	23:38:44.065	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	250.000000	28.925000	118.500000																																

$	19-Dec-2018	23:38:44.176	Init Mission	Starting valve open

$	19-Dec-2018	23:38:44.384	Init Mission	Bellows inside limits

$	19-Dec-2018	23:38:11.407	Init Mission	Unparsed SBE41 Message						S>middle_bin_interval=2  																														

$	19-Dec-2018	23:38:11.898	Init Mission	Unparsed SBE41 Message						S>middle_bin_size=2  																														

$	19-Dec-2018	23:38:12.398	Init Mission	Unparsed SBE41 Message						S>middle_bin_max=20  																														

$	19-Dec-2018	23:38:12.908	Init Mission	Unparsed SBE41 Message						S>bottom_bin_interval=2  																														

$	19-Dec-2018	23:38:13.398	Init Mission	Unparsed SBE41 Message						S>bottom_bin_size=2  																														

$	19-Dec-2018	23:38:13.912	Init Mission	Unparsed SBE41 Message						S>includetransitionbin=n  																														

$	19-Dec-2018	23:38:14.390	Init Mission	Unparsed SBE41 Message						S>includenbin=y  																														

$	19-Dec-2018	23:38:17.493	Init Mission	Optode Message																												!#  								

$	19-Dec-2018	23:38:18.498	Init Mission	Optode Message																												#  								

$	19-Dec-2018	23:38:19.510	Init Mission	Optode Message																												#  								

$	19-Dec-2018	23:38:45.557	Init Mission	MSC: RX: 

$	19-Dec-2018	23:38:45.756	Init Mission	MSC: RX: 

$	19-Dec-2018	23:38:45.858	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initializing... 

$	19-Dec-2018	23:38:45.960	Init Mission	MSC: RX:   MBARI Serial Number : 0777 

$	19-Dec-2018	23:38:45.967	Init Mission	MSC: RX:   CF2 App: APF_MAIN.C Date: Sep 30 2015 14:08:04 

$	19-Dec-2018	23:38:46.167	Init Mission	MSC: RX:   CF2 S/N: 14968 - BIOS:4.03 - PicoDOS:4.03 

$	19-Dec-2018	23:38:46.374	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	141.794488	28.925000	118.500000																																

$	19-Dec-2018	23:38:47.790	Init Mission	Increasing bellows position		142.596170																																		

$	19-Dec-2018	23:38:50.002	Init Mission	Increasing bellows position		142.922722																																		

$	19-Dec-2018	23:38:52.212	Init Mission	Increasing bellows position		143.279947																																		

$	19-Dec-2018	23:38:54.423	Init Mission	Increasing bellows position		143.563576																																		

$	19-Dec-2018	23:38:56.633	Init Mission	Increasing bellows position		143.738963																																		

$	19-Dec-2018	23:38:58.844	Init Mission	Increasing bellows position		143.742979																																		

$	19-Dec-2018	23:39:01.153	Init Mission	Increasing bellows position		143.792056																																		

$	19-Dec-2018	23:39:03.461	Init Mission	Increasing bellows position		143.798739																																		

$	19-Dec-2018	23:39:05.671	Init Mission	Increasing bellows position		143.799014																																		

$	19-Dec-2018	23:39:07.881	Init Mission	Increasing bellows position		143.819787																																		

$	19-Dec-2018	23:39:10.394	Init Mission	Decreasing bellows position		143.819623																																		

$	19-Dec-2018	23:39:12.605	Init Mission	Decreasing bellows position		143.832982																																		

$	19-Dec-2018	23:39:14.815	Init Mission	Decreasing bellows position		143.836156																																		

$	19-Dec-2018	23:39:17.026	Init Mission	Decreasing bellows position		143.858947																																		

$	19-Dec-2018	23:39:19.237	Init Mission	Decreasing bellows position		143.857591																																		

$	19-Dec-2018	23:39:21.448	Init Mission	Decreasing bellows position		143.851154																																		

$	19-Dec-2018	23:39:23.658	Init Mission	Decreasing bellows position		143.859662																																		

$	19-Dec-2018	23:39:25.869	Init Mission	Decreasing bellows position		143.863417																																		

$	19-Dec-2018	23:39:28.079	Init Mission	Decreasing bellows position		143.863596																																		

$	19-Dec-2018	23:39:30.296	Init Mission	Decreasing bellows position		143.871628																																		

$	19-Dec-2018	23:39:32.304	Init Mission	Radiometer Message																																	Satlantic OCR-504 Multispectral Radiometer 			

$	19-Dec-2018	23:39:32.502	Init Mission	Radiometer Message																																	Copyright (C) 2011, Satlantic Inc. All rights reserved. 			

$	19-Dec-2018	23:39:32.513	Init Mission	Radiometer Message																																	Firmware version: 5.1ent: SATFI4 			

$	19-Dec-2018	23:39:32.720	Init Mission	Radiometer Message																																	S/N: 0287 			

$	19-Dec-2018	23:39:32.731	Init Mission	Radiometer Message																																	Reset Source: Power 			

$	19-Dec-2018	23:39:32.839	Init Mission	Radiometer Message																																	Press <Ctrl+C> for command console. 			

$	19-Dec-2018	23:39:32.947	Init Mission	Radiometer Message																																	Initializing system. Please wait... 			

$	19-Dec-2018	23:39:33.155	Init Mission	MSC: RX:   CF Card: Size=256614400 Avail=98.95% 

$	19-Dec-2018	23:39:33.258	Init Mission	MSC: RX:   CF2 Power Up  (GMT): Tue Feb  7 06:04:00 2012 

$	19-Dec-2018	23:39:33.360	Init Mission	MSC: RX:   CF2 RTC Time  (GMT): Tue Feb  7 06:04:04 2012 

$	19-Dec-2018	23:39:33.463	Init Mission	MSC: RX:   Adjusted Local Time: Mon Feb  6 22:04:04 2012 

$	19-Dec-2018	23:39:33.565	Init Mission	MSC: RX:   TZ Offset (GMT - LOCAL)  : +8.00 hrs. 

$	19-Dec-2018	23:39:33.670	Init Mission	MSC: RX:   RTC delta (CF2 - DS3234) : +0.00 secs. 

$	19-Dec-2018	23:39:33.675	Init Mission	MSC: RX:   System Batt Voltage = 11.764 

$	19-Dec-2018	23:39:33.874	Init Mission	MSC: RX:   System Load Current = 2.62e-02 

$	19-Dec-2018	23:39:33.977	Init Mission	MSC: RX:   Housing Temperature = +21.64C = +70.95F 

$	19-Dec-2018	23:39:34.184	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	143.900320	28.925000	118.500000																																

$	19-Dec-2018	23:39:34.299	Init Mission	MSC: RX:   Housing    Humidity =  55.7%  =  12.4C (DP) 

$	19-Dec-2018	23:39:34.305	Init Mission	MSC: RX:   Power Cycle   Count = 211 

$	19-Dec-2018	23:39:34.407	Init Mission	MSC: RX:   System Reset  Count = 215 

$	19-Dec-2018	23:39:34.607	Init Mission	MSC: RX:   System Error  Count = 93 

$	19-Dec-2018	23:39:34.710	Init Mission	MSC: RX:   Last System   Error = -110 

$	19-Dec-2018	23:39:34.716	Init Mission	MSC: RX:   Last Error     Time = Mon Feb  6 23:46:23 2012 

$	19-Dec-2018	23:39:34.819	Init Mission	MSC: RX:   ISUS Error    Count = 1 

$	19-Dec-2018	23:39:34.921	Init Mission	MSC: RX:   Last ISUS     Error = -202 

$	19-Dec-2018	23:39:35.023	Init Mission	MSC: RX:   Last Error     Time = Thu Jan 26 03:13:44 2012 

$	19-Dec-2018	23:39:35.223	Init Mission	MSC: RX:   DURA Error    Count = 0 

$	19-Dec-2018	23:39:35.326	Init Mission	MSC: RX:   Last DURA     Error = 0 

$	19-Dec-2018	23:39:35.429	Init Mission	MSC: RX:   Last Error     Time = Thu Jan  1 00:00:00 1970 

$	19-Dec-2018	23:39:35.435	Init Mission	MSC: RX:   Fiberlite  Odometer = 100:16:01 = 360961 secs 

$	19-Dec-2018	23:39:35.635	Init Mission	MSC: RX:   Fiberlite    Cycles = 338 

$	19-Dec-2018	23:39:35.737	Init Mission	MSC: RX:   Spectrometer Status = MBARI-ISUS 1.1, 04-Mar-15, 10:16:08 

$	19-Dec-2018	23:39:35.840	Init Mission	MSC: RX:   Zeiss Coef File Found 4 coefs loaded. 

$	19-Dec-2018	23:39:36.146	Init Mission	PTH Message														783.982910	22.075000	54.871124	22.970386																			

$	19-Dec-2018	23:39:36.348	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.000000	143.901423	28.875000	173.000000																																

$	19-Dec-2018	23:39:36.459	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	23:39:36.464	Init Mission	Sending ds command

$	19-Dec-2018	23:39:36.669	Init Mission	MSC: RX:   Ecoef File Found 256 coefs loaded. 

$	19-Dec-2018	23:39:36.776	Init Mission	MSC: RX:   There are 99 records in the error file! 

$	19-Dec-2018	23:39:36.882	Init Mission	MSC: RX:   MBARI Sensor Controller (ISUS/DURA) Initialized 

$	19-Dec-2018	23:39:36.987	Init Mission	MSC: RX:   Auto Shutdown in 10 hours at: Tue Feb  7 16:04:05 2012 

$	19-Dec-2018	23:39:37.091	Init Mission	MSC: RX:   Entering Suspend Mode, Serial Input (/WAKE) will wake me, send M for Menu Mode  

$	19-Dec-2018	23:39:37.194	Init Mission	Radiometer Message																																	Autonomous operation enabled. 			

$	19-Dec-2018	23:38:34.052	Init Mission	SBE41 Message						   -1.02  	-1.020000	-0.000009	-0.000000	0.340000	0.170000	0.000000	3.000000																							

$	19-Dec-2018	23:39:37.637	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.873058	28.875000	173.000000																																

$	19-Dec-2018	23:39:37.749	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	23:39:38.056	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.891014	28.875000	173.000000																																

$	19-Dec-2018	23:39:38.749	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	23:39:36.666	Init Mission	Unparsed SBE41 Message						S>ds  																														

$	19-Dec-2018	23:39:36.774	Init Mission	Unparsed SBE41 Message						firmware compilation date: 18 December 2007 09:20  																														

$	19-Dec-2018	23:39:36.775	Init Mission	Unparsed SBE41 Message						stop profile when pressure is less than = 1.0 decibars  																														

$	19-Dec-2018	23:39:36.879	Init Mission	Unparsed SBE41 Message						automatic bin averaging at end of profile disabled  																														

$	19-Dec-2018	23:39:36.880	Init Mission	Unparsed SBE41 Message						number of samples = 255  																														

$	19-Dec-2018	23:39:36.881	Init Mission	Unparsed SBE41 Message						number of bins = 14  																														

$	19-Dec-2018	23:39:39.663	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.899955	28.875000	173.000000																																

$	19-Dec-2018	23:39:39.774	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	23:39:36.985	Init Mission	Unparsed SBE41 Message						top bin interval = 2  																														

$	19-Dec-2018	23:39:36.985	Init Mission	Unparsed SBE41 Message						top bin size = 2  																														

$	19-Dec-2018	23:39:36.986	Init Mission	Unparsed SBE41 Message						top bin max = 10  																														

$	19-Dec-2018	23:39:37.090	Init Mission	Unparsed SBE41 Message						middle bin interval = 2  																														

$	19-Dec-2018	23:39:37.194	Init Mission	Unparsed SBE41 Message						middle bin size = 2  																														

$	19-Dec-2018	23:39:37.207	Init Mission	Unparsed SBE41 Message						middle bin max = 20  																														

$	19-Dec-2018	23:39:37.306	Init Mission	Unparsed SBE41 Message						bottom bin interval = 2  																														

$	19-Dec-2018	23:39:37.326	Init Mission	Unparsed SBE41 Message						bottom bin size = 2  																														

$	19-Dec-2018	23:39:37.327	Init Mission	Unparsed SBE41 Message						do not include two transition bins  																														

$	19-Dec-2018	23:39:37.327	Init Mission	Unparsed SBE41 Message						include samples per bin  																														

$	19-Dec-2018	23:39:37.328	Init Mission	Unparsed SBE41 Message						pumped take sample wait time = 2 sec  																														

$	19-Dec-2018	23:39:37.329	Init Mission	Unparsed SBE41 Message						real-time output is PTS  																														

$	19-Dec-2018	23:39:41.390	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.885247	28.875000	173.000000																																

$	19-Dec-2018	23:39:41.506	Init Mission	Sending SBE41 ds command

$	19-Dec-2018	23:39:41.712	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.895932	28.875000	173.000000																																

$	19-Dec-2018	23:39:42.507	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	23:39:42.511	Init Mission	Sending dc command

$	19-Dec-2018	23:39:42.918	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.890008	28.875000	173.000000																																

$	19-Dec-2018	23:39:43.506	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	23:39:42.714	Init Mission	Unparsed SBE41 Message						S>dc  																														

$	19-Dec-2018	23:39:42.715	Init Mission	Unparsed SBE41 Message						temperature:  15-mar-14  																														

$	19-Dec-2018	23:39:42.742	Init Mission	Unparsed SBE41 Message						    TA0 =  3.536242e-05  																														

$	19-Dec-2018	23:39:42.778	Init Mission	Unparsed SBE41 Message						    TA1 =  2.674251e-04  																														

$	19-Dec-2018	23:39:42.814	Init Mission	Unparsed SBE41 Message						    TA2 = -1.901062e-06  																														

$	19-Dec-2018	23:39:42.850	Init Mission	Unparsed SBE41 Message						    TA3 =  1.365250e-07  																														

$	19-Dec-2018	23:39:42.886	Init Mission	Unparsed SBE41 Message						conductivity:  15-mar-14  																														

$	19-Dec-2018	23:39:43.030	Init Mission	Unparsed SBE41 Message						    G = -9.858232e-01  																														

$	19-Dec-2018	23:39:43.030	Init Mission	Unparsed SBE41 Message						    H =  1.476071e-01  																														

$	19-Dec-2018	23:39:43.031	Init Mission	Unparsed SBE41 Message						    I = -3.292498e-04  																														

$	19-Dec-2018	23:39:43.032	Init Mission	Unparsed SBE41 Message						    J =  4.505543e-05  																														

$	19-Dec-2018	23:39:43.059	Init Mission	Unparsed SBE41 Message						    CPCOR = -9.570001e-08  																														

$	19-Dec-2018	23:39:43.097	Init Mission	Unparsed SBE41 Message						    CTCOR =  3.250000e-06  																														

$	19-Dec-2018	23:39:43.136	Init Mission	Unparsed SBE41 Message						    WBOTC = -3.218098e-07  																														

$	19-Dec-2018	23:39:43.218	Init Mission	Unparsed SBE41 Message						pressure S/N = 4004719, range = 2900 psia:  10-mar-14  																														

$	19-Dec-2018	23:39:45.579	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.885091	28.875000	173.000000																																

$	19-Dec-2018	23:39:45.690	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	23:39:43.255	Init Mission	Unparsed SBE41 Message						    PA0 =  1.629284e-01  																														

$	19-Dec-2018	23:39:43.291	Init Mission	Unparsed SBE41 Message						    PA1 =  1.404717e-01  																														

$	19-Dec-2018	23:39:43.326	Init Mission	Unparsed SBE41 Message						    PA2 = -3.503310e-08  																														

$	19-Dec-2018	23:39:43.366	Init Mission	Unparsed SBE41 Message						    PTCA0 =  2.758681e+01  																														

$	19-Dec-2018	23:39:43.404	Init Mission	Unparsed SBE41 Message						    PTCA1 =  2.201518e-02  																														

$	19-Dec-2018	23:39:43.442	Init Mission	Unparsed SBE41 Message						    PTCA2 =  1.374282e-03  																														

$	19-Dec-2018	23:39:43.481	Init Mission	Unparsed SBE41 Message						    PTCB0 =  2.510888e+01  																														

$	19-Dec-2018	23:39:43.608	Init Mission	Unparsed SBE41 Message						    PTCB1 =  1.175000e-03  																														

$	19-Dec-2018	23:39:43.609	Init Mission	Unparsed SBE41 Message						    PTCB2 =  0.000000e+00  																														

$	19-Dec-2018	23:39:43.610	Init Mission	Unparsed SBE41 Message						    PTHA0 = -7.442904e+01  																														

$	19-Dec-2018	23:39:43.729	Init Mission	Unparsed SBE41 Message						    PTHA1 =  4.994783e-02  																														

$	19-Dec-2018	23:39:43.730	Init Mission	Unparsed SBE41 Message						    PTHA2 = -3.966033e-07  																														

$	19-Dec-2018	23:39:43.731	Init Mission	Unparsed SBE41 Message						    POFFSET =  0.000000e+00  																														

$	19-Dec-2018	23:39:47.425	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.896297	28.875000	173.000000																																

$	19-Dec-2018	23:39:47.538	Init Mission	Sending SBE41 dc command

$	19-Dec-2018	23:39:47.842	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.899016	28.875000	173.000000																																

$	19-Dec-2018	23:39:48.739	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	-1.020000	143.896841	28.875000	173.000000																																

$	19-Dec-2018	23:39:49.538	Init Mission	Sending Optode GetAll

$	19-Dec-2018	23:39:49.542	Init Mission	Sending Optode Wakeup

$	19-Dec-2018	23:39:49.511	Init Mission	SBE41 Message						    0.95  	0.950000	-0.002151	-0.000025	-0.656667	-0.158333	0.000000	3.000000																							

$	19-Dec-2018	23:39:50.311	Init Mission	Optode Message																												%!Product Name,4330,1532,Optode Sensor  								

$	19-Dec-2018	23:39:50.344	Init Mission	Optode Message																												Product Number,4330,1532,4330  								

$	19-Dec-2018	23:39:50.375	Init Mission	Optode Message																												Serial Number,4330,1532,1532  								

$	19-Dec-2018	23:39:50.401	Init Mission	Optode Message																												SW ID,4330,1532,1940006  								

$	19-Dec-2018	23:39:50.430	Init Mission	Optode Message																												SW Version,4330,1532,4,8,1  								

$	19-Dec-2018	23:39:50.471	Init Mission	Optode Message																												Node Description,4330,1532,optode 1532  								

$	19-Dec-2018	23:39:50.490	Init Mission	Optode Message																												Owner,4330,1532,  								

$	19-Dec-2018	23:39:50.521	Init Mission	Optode Message																												Salinity[PSU],4330,1532,0.00  								

$	19-Dec-2018	23:39:50.597	Init Mission	Optode Message																												PhaseCoef,4330,1532,3.795891E-01,9.893345E-01,0.000000E+00,0.000000E+00  								

$	19-Dec-2018	23:39:50.622	Init Mission	Optode Message																												FoilID,4330,1532,1206E  								

$	19-Dec-2018	23:39:50.841	Init Mission	Optode Message																												FoilCoefA,4330,1532,-2.988314E-06,-6.137784E-06,1.684659E-03,-1.857173E-01,6.784399E-04,-5.597907E-07,1.040158E+01,-5.986906E-02,1.360425E-04,-4.776978E-07,-3.032936E+02,2.530496E+00,-1.267045E-02,1.040454E-04  								

$	19-Dec-2018	23:39:51.057	Init Mission	Optode Message																												FoilCoefB,4330,1532,-3.560390E-07,3.816713E+03,-4.475507E+01,4.386164E-01,-7.146341E-03,8.906235E-05,-6.343012E-07,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	19-Dec-2018	23:39:51.139	Init Mission	Optode Message																												FoilPolyDegT,4330,1532,1,0,0,0,1,2,0,1,2,3,0,1,2,3,4,0,1,2,3,4,5,0,0,0,0,0,0,0  								

$	19-Dec-2018	23:39:54.938	Init Mission	Normal State Exit

$	19-Dec-2018	23:39:55.042	Init Mission	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.950000	143.910944	28.875000	173.000000																																

$	19-Dec-2018	23:39:55.161	Init Profile	State Entry

$	19-Dec-2018	23:39:55.267	Init Profile	Initializing SBE 41 LPF

$	19-Dec-2018	23:39:55.375	Init Profile	Sending SBE41 stopProfile

$	19-Dec-2018	23:39:56.380	Init Profile	Resetting SBE41 with qsr

$	19-Dec-2018	23:39:56.384	Init Profile	Sending qsr command

$	19-Dec-2018	23:39:51.222	Init Profile	Optode Message																												FoilPolyDegO,4330,1532,4,5,4,3,3,3,2,2,2,2,1,1,1,1,1,0,0,0,0,0,0,0,0,0,0,0,0,0  								

$	19-Dec-2018	23:39:51.341	Init Profile	Optode Message																												SVUFoilCoef,4330,1532,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00,0.000000E+00  								

$	19-Dec-2018	23:39:51.389	Init Profile	Optode Message																												ConcCoef,4330,1532,-1.549127E+00,1.068129E+00  								

$	19-Dec-2018	23:39:51.427	Init Profile	Optode Message																												NomAirPress[hPa],4330,1532,1013.25  								

$	19-Dec-2018	23:39:51.457	Init Profile	Optode Message																												NomAirMix,4330,1532,0.20946  								

$	19-Dec-2018	23:39:51.497	Init Profile	Optode Message																												CalDataSat[Deg],4330,1532,31.61,10.06  								

$	19-Dec-2018	23:39:51.539	Init Profile	Optode Message																												CalDataAPress[hPa],4330,1532,1002.000  								

$	19-Dec-2018	23:39:51.582	Init Profile	Optode Message																												CalDataZero[Deg],4330,1532,61.907,21.413  								

$	19-Dec-2018	23:39:51.621	Init Profile	Optode Message																												Mode,4330,1532,Smart Sensor Terminal  								

$	19-Dec-2018	23:39:51.651	Init Profile	Optode Message																												Enable Sleep,4330,1532,Yes  								

$	19-Dec-2018	23:39:51.686	Init Profile	Optode Message																												Enable Polled Mode,4330,1532,Yes  								

$	19-Dec-2018	23:39:51.713	Init Profile	Optode Message																												Enable Text,4330,1532,No  								

$	19-Dec-2018	23:39:51.751	Init Profile	Optode Message																												Enable Decimalformat,4330,1532,Yes  								

$	19-Dec-2018	23:39:51.799	Init Profile	Optode Message																												Analog TempLimit[Deg.C],4330,1532,-5.00,35.00  								

$	19-Dec-2018	23:39:51.848	Init Profile	Optode Message																												Analog ConcLimit[Deg.C],4330,1532,0.00,800.00  								

$	19-Dec-2018	23:39:51.896	Init Profile	Optode Message																												Analog SatLimit[Deg.C],4330,1532,0.00,200.00  								

$	19-Dec-2018	23:40:00.482	Init Profile	Normal State Exit

$	19-Dec-2018	23:40:00.487	Init Profile	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.950000	143.918611	28.875000	173.000000																																

$	19-Dec-2018	23:40:00.700	Init Profile	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:05.5382927

$	19-Dec-2018	23:40:00.707	Surface Ops Set Bellows	State Entry

$	19-Dec-2018	23:40:00.911	Surface Ops Set Bellows	Inflating bellows to Surface Ops position = 155.0 at 200000 cps

$	19-Dec-2018	23:39:51.945	Surface Ops Set Bellows	Optode Message																												Analog PhaseLimit[Deg.C],4330,1532,10.00,70.00  								

$	19-Dec-2018	23:39:51.988	Surface Ops Set Bellows	Optode Message																												Analog Output,4330,1532,O2Concentration  								

$	19-Dec-2018	23:39:52.042	Surface Ops Set Bellows	Optode Message																												Analog1 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	19-Dec-2018	23:39:52.092	Surface Ops Set Bellows	Optode Message																												Analog2 Coef,4330,1532,0.000000E+00,1.000000E+00  								

$	19-Dec-2018	23:39:52.128	Surface Ops Set Bellows	Optode Message																												Enable AirSaturation,4330,1532,No  								

$	19-Dec-2018	23:39:52.160	Surface Ops Set Bellows	Optode Message																												Enable Rawdata,4330,1532,Yes  								

$	19-Dec-2018	23:39:52.195	Surface Ops Set Bellows	Optode Message																												Enable Temperature,4330,1532,Yes  								

$	19-Dec-2018	23:39:52.231	Surface Ops Set Bellows	Optode Message																												Enable HumidityComp,4330,1532,Yes  								

$	19-Dec-2018	23:39:52.265	Surface Ops Set Bellows	Optode Message																												Enable SVUformula,4330,1532,No  								

$	19-Dec-2018	23:39:52.295	Surface Ops Set Bellows	Optode Message																												Interval[s],4330,1532,30.000  								

$	19-Dec-2018	23:39:52.318	Surface Ops Set Bellows	Optode Message																												Location,4330,1532,  								

$	19-Dec-2018	23:39:52.369	Surface Ops Set Bellows	Optode Message																												Geographic Position,4330,1532,60.323605,5.37225  								

$	19-Dec-2018	23:39:52.399	Surface Ops Set Bellows	Optode Message																												Vertical Position,4330,1532,  								

$	19-Dec-2018	23:39:52.423	Surface Ops Set Bellows	Optode Message																												Reference,4330,1532,  								

$	19-Dec-2018	23:39:52.426	Surface Ops Set Bellows	Optode Message																												#  								

$	19-Dec-2018	23:40:03.213	Surface Ops Set Bellows	Normal State Exit

$	19-Dec-2018	23:40:03.218	Surface Ops Set Bellows	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.950000	143.923856	28.875000	173.000000																																

$	19-Dec-2018	23:40:03.433	Surface Ops Set Bellows	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.7257610

$	19-Dec-2018	23:40:03.536	Pre-Mission Delay	State Entry

$	19-Dec-2018	23:39:52.510	Pre-Mission Delay	SBE41 Message						    0.94  	0.940000	0.950000	-0.000000	0.003333	0.001667	0.000000	3.000000																							

$	19-Dec-2018	23:40:03.970	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.940000	143.919751	28.875000	173.000000																																

$	19-Dec-2018	23:39:55.516	Pre-Mission Delay	SBE41 Message						   -0.65  	-0.650000	0.949965	-0.000000	0.530000	0.266667	0.000000	3.000000																							

$	19-Dec-2018	23:39:58.584	Pre-Mission Delay	SBE41 Message						    0.74  	0.740000	0.946371	-0.000042	-0.463333	0.033333	0.000004	3.000000																							

$	19-Dec-2018	23:40:04.988	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.740000	143.893138	28.875000	173.000000																																

$	19-Dec-2018	23:40:05.740	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.740000	143.898115	28.875000	173.000000																																

$	19-Dec-2018	23:40:02.223	Pre-Mission Delay	Unparsed SBE41 Message						S>  																														

$	19-Dec-2018	23:40:06.857	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.740000	143.928111	28.875000	173.000000																																

$	19-Dec-2018	23:40:04.555	Pre-Mission Delay	SBE41 Message						    0.44  	0.440000	0.910106	-0.000325	0.100000	-0.181667	0.000054	3.000000																							

$	19-Dec-2018	23:40:07.510	Pre-Mission Delay	SBE41 Message						    0.42  	0.420000	0.778221	-0.000291	0.006667	0.053333	0.000264	3.000000																							

$	19-Dec-2018	23:40:07.988	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.924497	28.875000	173.000000																																

$	19-Dec-2018	23:40:08.740	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.913902	28.875000	173.000000																																

$	19-Dec-2018	23:40:09.739	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.910684	28.875000	173.000000																																

$	19-Dec-2018	23:40:10.511	Pre-Mission Delay	SBE41 Message						    0.44  	0.440000	0.550707	0.003756	-0.006667	0.000000	0.000747	3.000000																							

$	19-Dec-2018	23:40:10.863	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.440000	143.921778	28.875000	173.000000																																

$	19-Dec-2018	23:40:11.740	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.440000	143.929392	28.875000	173.000000																																

$	19-Dec-2018	23:40:12.739	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.440000	143.921457	28.875000	173.000000																																

$	19-Dec-2018	23:40:13.511	Pre-Mission Delay	SBE41 Message						    0.43  	0.430000	0.367942	0.016522	0.003333	-0.001667	0.001432	3.000000																							

$	19-Dec-2018	23:40:28.292	Pre-Mission Delay	Error in ADC2485.readValue Method

$	19-Dec-2018	23:40:28.394	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.430000	250.000000	28.875000	173.000000																																

$	19-Dec-2018	23:40:28.505	Pre-Mission Delay	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:14.9684212

$	19-Dec-2018	23:40:28.811	Pre-Mission Delay	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.430000	143.932834	28.875000	173.000000																																

$	19-Dec-2018	23:40:35.887	Pre-Mission Delay	State Timed Out

$	19-Dec-2018	23:40:35.992	Surface Ops	State Entry

$	19-Dec-2018	23:40:36.099	Surface Ops	Powering up Iridium Modem

$	19-Dec-2018	23:40:46.001	Surface Ops	Starting valve close

$	19-Dec-2018	23:40:46.005	Surface Ops	Sending SBDD2 cmd

$	19-Dec-2018	23:40:46.415	Surface Ops	PTH Message														784.467041	22.175000	54.466766	23.174163																			

$	19-Dec-2018	23:40:46.618	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Open, depthNum = 0  Pres, BP, BatV, BatI: 	0.430000	143.925644	28.825000	261.000000																																

$	19-Dec-2018	23:40:46.730	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:10.7120861

$	19-Dec-2018	23:40:36.349	Surface Ops	SBE41 Message						    0.89  	0.890000	0.343480	0.035178	-0.153333	-0.075000	0.002221	3.000000																							

$	19-Dec-2018	23:40:39.044	Surface Ops	Unparsed SBE41 Message						S>  																														

$	19-Dec-2018	23:40:39.114	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:47.188	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:39.116	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:47.400	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:40.114	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:47.613	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:40.116	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:47.825	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:41.116	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:48.045	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:41.118	Surface Ops	A3LA Message																																			0  	

$	19-Dec-2018	23:40:48.258	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	19-Dec-2018	23:40:41.119	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:48.470	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:48.778	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.890000	143.930383	28.825000	261.000000																																

$	19-Dec-2018	23:40:48.889	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1538834

$	19-Dec-2018	23:40:41.121	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:49.101	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:41.511	Surface Ops	SBE41 Message						    0.44  	0.440000	0.405767	0.048279	0.150000	-0.001667	0.002799	3.000000																							

$	19-Dec-2018	23:40:42.115	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:49.438	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:42.124	Surface Ops	A3LA Message																																			300125060561320  	

$	19-Dec-2018	23:40:49.651	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->300125060561320  <--  

$	19-Dec-2018	23:40:42.126	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:49.863	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:42.128	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:50.078	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:43.117	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:50.292	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:43.118	Surface Ops	A3LA Message																																			0  	

$	19-Dec-2018	23:40:50.503	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	19-Dec-2018	23:40:43.120	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:50.717	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:43.122	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:50.929	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:44.117	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:51.141	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:44.119	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:51.356	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:44.509	Surface Ops	SBE41 Message						    0.48  	0.480000	0.449478	0.046982	-0.013333	0.068333	0.003223	3.000000																							

$	19-Dec-2018	23:40:45.118	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:51.694	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:51.999	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.480000	143.955790	28.825000	261.000000																																

$	19-Dec-2018	23:40:52.110	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:03.2155347

$	19-Dec-2018	23:40:45.129	Surface Ops	A3LA Message																																			8988169234000597401  	

$	19-Dec-2018	23:40:52.324	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->8988169234000597401  <--  

$	19-Dec-2018	23:40:45.130	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:52.535	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:45.132	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:52.748	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:46.210	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:52.960	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:46.210	Surface Ops	A3LA Message																																			0  	

$	19-Dec-2018	23:40:53.175	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->0  <--  

$	19-Dec-2018	23:40:46.211	Surface Ops	A3LA Message																																			  	

$	19-Dec-2018	23:40:53.388	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->  <--  

$	19-Dec-2018	23:40:46.211	Surface Ops	A3LA Message																																			OK  	

$	19-Dec-2018	23:40:53.600	Surface Ops	iModem invalid response: Looking for IModem-->AT+SBDD2<--  Got-->OK  <--  

$	19-Dec-2018	23:40:47.613	Surface Ops	SBE41 Message						    1.25  	1.250000	0.484168	0.031985	-0.256667	-0.135000	0.003534	3.000000																							

$	19-Dec-2018	23:40:50.607	Surface Ops	SBE41 Message						    1.59  	1.590000	0.540042	0.010248	-0.113333	-0.185000	0.003724	3.000000																							

$	19-Dec-2018	23:40:53.703	Surface Ops	SBE41 Message						    1.17  	1.170000	0.594430	-0.008675	0.140000	0.013333	0.003814	3.000000																							

$	19-Dec-2018	23:40:54.182	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	1.170000	143.934481	28.825000	261.000000																																

$	19-Dec-2018	23:40:54.295	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:02.1792729

$	19-Dec-2018	23:40:54.600	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	1.170000	143.940814	28.825000	261.000000																																

$	19-Dec-2018	23:40:55.504	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	1.170000	143.945061	28.825000	261.000000																																

$	19-Dec-2018	23:40:56.503	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	1.170000	143.958621	28.825000	261.000000																																

$	19-Dec-2018	23:40:56.613	Surface Ops	SBE41 Message						    0.93  	0.930000	0.661547	-0.017010	0.080000	0.110000	0.003806	3.000000																							

$	19-Dec-2018	23:40:57.627	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.930000	143.967658	28.825000	261.000000																																

$	19-Dec-2018	23:40:58.503	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.930000	143.965617	28.825000	261.000000																																

$	19-Dec-2018	23:40:59.504	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.930000	143.957324	28.825000	261.000000																																

$	19-Dec-2018	23:40:59.616	Surface Ops	SBE41 Message						    0.75  	0.750000	0.816422	-0.016719	0.060000	0.070000	0.003612	3.000000																							

$	19-Dec-2018	23:41:00.530	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.750000	143.950030	28.825000	261.000000																																

$	19-Dec-2018	23:41:01.505	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.750000	143.947147	28.825000	261.000000																																

$	19-Dec-2018	23:41:02.505	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.750000	143.973067	28.825000	261.000000																																

$	19-Dec-2018	23:41:02.615	Surface Ops	SBE41 Message						    0.41  	0.410000	1.042806	-0.018837	0.113333	0.086667	0.003179	3.000000																							

$	19-Dec-2018	23:41:03.629	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.410000	143.950194	28.825000	261.000000																																

$	19-Dec-2018	23:41:04.505	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.410000	143.954888	28.825000	261.000000																																

$	19-Dec-2018	23:41:05.506	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.410000	143.942840	28.825000	261.000000																																

$	19-Dec-2018	23:41:05.618	Surface Ops	SBE41 Message						    0.42  	0.420000	1.185718	-0.029947	-0.003333	0.055000	0.002628	3.000000																							

$	19-Dec-2018	23:41:06.531	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.954478	28.825000	261.000000																																

$	19-Dec-2018	23:41:07.507	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.954597	28.825000	261.000000																																

$	19-Dec-2018	23:41:08.507	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.974133	28.825000	261.000000																																

$	19-Dec-2018	23:41:08.618	Surface Ops	SBE41 Message						    0.44  	0.440000	1.137991	-0.044180	-0.006667	-0.005000	0.002171	3.000000																							

$	19-Dec-2018	23:41:09.632	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.440000	143.966079	28.825000	261.000000																																

$	19-Dec-2018	23:41:10.508	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.440000	143.974766	28.825000	261.000000																																

$	19-Dec-2018	23:41:11.508	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.440000	143.967353	28.825000	261.000000																																

$	19-Dec-2018	23:41:11.621	Surface Ops	SBE41 Message						    0.42  	0.420000	0.951293	-0.049869	0.006667	0.000000	0.001935	3.000000																							

$	19-Dec-2018	23:41:12.633	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.953390	28.825000	261.000000																																

$	19-Dec-2018	23:41:25.466	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.964589	28.825000	261.000000																																

$	19-Dec-2018	23:41:25.579	Surface Ops	ERROR: State machine cycle time exceeded SMCyclePeriod = 00:00:12.2726770

$	19-Dec-2018	23:41:25.884	Surface Ops	RecMode true, PID Off, Motor Stopped, Valve Closed, depthNum = 0  Pres, BP, BatV, BatI: 	0.420000	143.954277	28.825000	261.000000																																

$	19-Dec-2018	23:41:26.584	Surface Ops	Powering up 4330 Optode

$	19-Dec-2018	23:41:28.091	Surface Ops	Sending Optode Wakeup

$	19-Dec-2018	23:41:32.098	Surface Ops	Powering up OCR504

$	19-Dec-2018	23:41:32.200	Surface Ops	Closing old .eng file: \SD\data\cpf001.000.2018-12-19T23-37-33.eng

