﻿<?xml version="1.0" encoding="utf-8"?>
<document version="1.5" language="en-us">
  <include target="Library.DateTime" />
  <include target="Library.Math" />
  <include target="Library.Logic" />
  <include target="Library.Lookup" />
  <include target="Library.Statistics" />
  <include target="Library.Text" />
  <include target="Library.Scripts" />
  <report title="Report 1" name="Report1" unit="in" pagesize="816, 1056">
    <paragraph>
      <dynexp formula="currentRes = 500*10^-6ohm">
        <expbody>currentRes = 500*10^-6ohm</expbody>
        <expresult> = 0.0005 ohm</expresult>
      </dynexp>
    </paragraph>
    <paragraph />
    <paragraph>This is shunt is spected normizing for current between +/-165A</paragraph>
    <paragraph />
    <paragraph>
      <dynexp formula="OpAmpGain = 0.01 V/A">
        <expbody>OpAmpGain = 0.01 V/A</expbody>
      </dynexp>
    </paragraph>
    <paragraph>
      <dynexp formula="MaxDefultCurrent = 165A">
        <expbody>MaxDefultCurrent = 165A</expbody>
      </dynexp>
    </paragraph>
    <paragraph />
    <paragraph>
      <dynexp formula="MaxSences = OpAmpGain*MaxDefultCurrent">
        <expbody>MaxSences = OpAmpGain*MaxDefultCurrent</expbody>
        <expresult> = 1.65 V</expresult>
      </dynexp>
    </paragraph>
    <paragraph />
    <paragraph>
      <dynexp formula="AcctualMaxCurrent = 10A">
        <expbody>AcctualMaxCurrent = 10A</expbody>
      </dynexp>
    </paragraph>
    <paragraph />
    <paragraph>Scale the shunt resistance</paragraph>
    <paragraph>
      <dynexp formula="ShuntScaller = 10">
        <expbody>ShuntScaller = 10</expbody>
      </dynexp>
    </paragraph>
    <paragraph>
      <dynexp formula="NewShunt=ShuntScaller*currentRes">
        <expbody>NewShunt=ShuntScaller*currentRes</expbody>
        <expresult> = 0.005 ohm</expresult>
      </dynexp>
    </paragraph>
    <paragraph />
    <paragraph>
      <dynexp formula="Power = AcctualMaxCurrent^2*NewShunt to W">
        <expbody>Power = AcctualMaxCurrent^2*NewShunt to W</expbody>
        <expresult> = 0.5 W</expresult>
      </dynexp>
       
    </paragraph>
    <paragraph />
    <paragraph>
      <dynexp formula="CurrentNormMax = 16.5">
        <expbody>CurrentNormMax = 16.5</expbody>
      </dynexp>
    </paragraph>
    <paragraph />
    <paragraph>
      <dynexp formula="Rnew = 1.65/CurrentNormMax">
        <expbody>Rnew = 1.65/CurrentNormMax</expbody>
        <expresult> = 0.1</expresult>
      </dynexp>
    </paragraph>
    <paragraph />
  </report>