HR: 14:55h
AN: H12H-06 [PDF]
TI: Low-Frequency Electrical Properties of Zero Vvalent Iron-Sand Columns: Implications for Monitoring the
Performance of Reactive Iron Wall Barriers
AU: * Choi, J
EM: fiam3620@hotmail.com
AF: Rutgers University, Earth/Environmental Sciences, 195 University Ave., Newark, NJ 07102 United States
AU: Slater, L D
EM: lslater@andromeda.rutgers.edu
AF: Rutgers University, Earth/Environmental Sciences, 195 University Ave., Newark, NJ 07102 United States
AU: Wu, Y
EM: yuxinwu@pegasus.rutgers.edu
AF: Rutgers University, Earth/Environmental Sciences, 195 University Ave., Newark, NJ 07102 United States
AB:
The reactive iron barrier is an in-situ technology for passive remediation of chlorinated solvents and heavy metals. Redox
reactions occurring on the iron surface effectively remove these contaminants from groundwater. The effectiveness of this
redox reaction diminishes with time due to oxidation and precipitation occurring on the metal surface, such that the
long-term performance of reactive barriers is uncertain. Non-invasive measurement methods for evaluating reactive barrier
performance are thus required to support remedial strategies at reactive barrier installations.
Low-frequency (0.1-1000 Hz) electrical measurements are sensitive to the electrochemistry of the metal surface-pore fluid
interface. We are conducting a series of laboratory experiments to assess the sensitivity of electrical methods (induced
polarization and resistivity) to changes in the physicochemical properties of the metal-fluid interface that occur over time.
In this paper we present the results of baseline studies on zero-valent iron-sand columns as a function of (a) reactive iron
concentration (b) saturating fluid chemistry, and (c) degree of surface oxidation.
The sensitivity of low-frequency electrical parameters to total zero-valent iron (Fe0) surface area was investigated by
synthesizing Fe-Ottawa sand samples with varying Fe0 concentration from 0-10 percent. The dependence on ionic strength and
electrolyte activity was investigated by making measurements on samples saturated with 0.001-1.0 for NaNO3, NaCl and CaCl2
solutions. The effect of pH was evaluated at constant electrolyte activity. As a first step towards evaluating the
sensitivity of electrical measurements to reduction in reactive iron performance, measurements were made over a three month
period of ageing and correlated with geochemical indicators (pH, Eh, electrical conductivity, iron concentrations) of Fe
surface oxidation and precipitation.
We find that induced polarization (IP) parameters are highly sensitive to Fe0 surface area whereas conduction parameters
measured with the resistivity method are insensitive to Fe0 concentration over the investigated range. Polarization at the
iron-electrolyte interface shows a power law relationship with electrolyte activity for all solutions and is consistent with
Warburg impedance theory. Power-law exponents are slightly higher than that predicted for the active ion species based on
Warburg impedance theory. Polarization magnitude depends on ionic composition of the electrolyte with the magnitude following
the order CaCl2: NaCl: NaNO3. Conduction parameters are insensitive to ionic composition at constant electrolyte activity.
Electrolyte activity exerts a strong control on the polarization relaxation length-scale, with time constant of the
relaxation decreasing with increasing electrolyte activity. Polarization parameters measured during three months of ageing
are clearly correlated with time and suggest that electrical measurements are sensitive to reduction in reactive iron
performance.
DE: 0925 Magnetic and electrical methods
DE: 1099 General or miscellaneous
DE: 1894 Instruments and techniques
DE: 5109 Magnetic and electrical properties
SC: Hydrology [H]
MN: 2003 Fall Meeting