HR: 0830h
AN: H51C-1069 [PDF]
TI: Source Water Assessment for the Las Vegas Valley Surface Waters
AU: * Albuquerque, S P
EM: albuque2@unlv.edu
AF: University of Nevada Las Vegas
Department of Civil and Environmental Engineering, 4505 Maryland Parkway Box 454015, Las Vegas, NV 89154-4015
AU: Piechota, T C
EM: piechota@unlv.edu
AF: University of Nevada Las Vegas
Department of Civil and Environmental Engineering, 4505 Maryland Parkway Box 454015, Las Vegas, NV 89154-4015
AB:
The 1996 amendment to the Safe Drinking Water Act of 1974 created the Source Water Assessment Program (SWAP) with an
objective to evaluate potential sources of contamination to drinking water intakes. The development of a Source Water
Assessment Plan for Las Vegas Valley surface water runoff into Lake Mead is important since it will guide future work on
source water protection of the main source of water. The first step was the identification of the watershed boundary and
source water protection area. Two protection zones were delineated. Zone A extends 500 ft around water bodies, and Zone B
extends 3000 ft from the boundaries of Zone A. These Zones extend upstream to the limits of dry weather flows in the storm
channels within the Las Vegas Valley. After the protection areas were identified, the potential sources of contamination in
the protection area were inventoried. Field work was conducted to identify possible sources of contamination. A GIS coverage
obtained from local data sources was used to identify the septic tank locations. Finally, the National Pollutant Discharge
Elimination System (NPDES) Permits were obtained from the State of Nevada, and included in the inventory. After the inventory
was completed, a level of risk was assigned to each potential contaminating activity (PCA). The contaminants of concern were
grouped into five categories: volatile organic compounds (VOCs), synthetic organic compounds (SOCs), inorganic compounds
(IOCs), microbiological, and radionuclides. The vulnerability of the water intake to each of the PCAs was assigned based on
these five categories, and also on three other factors: the physical barrier effectiveness, the risk potential, and the time
of travel. The vulnerability analysis shows that the PCAs with the highest vulnerability rating include septic systems, golf
courses/parks, storm channels, gas stations, auto repair shops, construction, and the wastewater treatment plant discharges.
Based on the current water quality data (prior to treatment), the proximity of Las Vegas Wash to the intake, and the results
of the vulnerability analysis of potential contaminating activities, it is determined that the drinking water intake is at a
Moderate level of risk for VOC, SOC, and microbiological contaminants. The drinking water intake is at a High level of risk
for IOC contaminants. Vulnerability to radiological contamination is Moderate. Source water protection in the Las Vegas
Valley is strongly encouraged because of the documented influence of the Las Vegas Wash on the quality of the water at the
intake.
DE: 1871 Surface water quality
DE: 1884 Water supply
SC: Hydrology [H]
MN: 2003 Fall Meeting