HR: 1340h
AN: A43B-0091    [Abstracts]
TI: Altitude Registration Analysis of Limb Scattering Observations
AU: * Taha, G
EM: ghassan_taha@ssaihq.com
AF: Science Systems and Applications, Inc., 10210 Greenbelt Road, Lanham, MD 20706 United States
AU: Jaross, G
EM: jaross@qhearts.gsfc.nasa.gov
AF: Science Systems and Applications, Inc., 10210 Greenbelt Road, Lanham, MD 20706 United States
AU: Rault, D F
EM: Didier.F.Rault@nasa.gov
AF: NASA Langley Research Center, Climate Science Branch, MS 475, Hampton, VA 23681 United States
AU: Tzortziou, M
EM: martz@carioca.gsfc.nasa.gov
AF: Earth System Science Interdisciplinary Center, University of Maryland, 2207 Computer and Space Science Building, College Park, MD 20742-2465
AU: McPeters, R D
EM: Richard.D.McPeters@nasa.gov
AF: NASA Goddard Space Flight Center, Laboratory for Atmospheres, Code 613.3, Greenbelt, MD 20771 United States
AB: Altitude registration remains one of the most challenging problems for retrieving atmospheric composition profiles from limb scattering observations, mainly because, unlike solar occultation, there is no well-defined target. Inaccuracies in altitude registration often affect the accuracy and precision of the retrieved trace gas profiles, and hence hinder the scientific value of such measurements. Pointing offset has been identified as the largest contributor to Ozone Mapping and Profiler Suite (OMPS) limb precision errors between the tropopause and the ozone peak. In this work, we investigate the limb scattering pointing accuracy of SAGE III, OSIRIS, and SCIAMACHY, by comparison between retrieved ozone profiles and highly accurate correlative measurements, such as occultation sensors, balloonsondes and lidars. Using these comparisons we assess the accuracy of the limb scattering altitude registration. The limb scattering instruments obtain their pointing information via various techniques, including RSAS and the knee method (SAGE III), star-tracker (OSIRIS), and knowledge of internal scan-mirror position and satellite location and orientation (SCIAMACHY). Preliminary results of this work are in good agreement with the known altitude registration errors for these sensors. Results from this work will provide guidance to the Integrated Program Office (IPO) and Product Evaluation and Test Elements (PEATE) in their effort to evaluate the accuracy, precession and long tem stability of OMPS instrument onboard NPP and NPOESS.
DE: 0300 ATMOSPHERIC COMPOSITION AND STRUCTURE
DE: 0340 Middle atmosphere: composition and chemistry
DE: 0360 Radiation: transmission and scattering
DE: 0394 Instruments and techniques
SC: Atmospheric Sciences [A]
MN: Fall Meeting 2005