HR: 0800h
AN: B41B-0184 [Abstracts]
TI: Application of the variance method for CO2 flux to aircraft measurement
AU: * Shimoyama, K
EM: shimoyama.kou@nies.go.jp
AF: National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, 305-8506
Japan
AU: Machida, T
EM: tmachida@nies.go.jp
AF: National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, 305-8506
Japan
AU: Krasnov, O
EM: krasnov@iao.ru
AF: Institute of Atmospheric Optics, SB RAS, Akademicheskii av.1, Tomsk, 634055
Russian Federation
AU: Belan, B
EM: bbd@iao.ru
AF: Institute of Atmospheric Optics, SB RAS, Akademicheskii av.1, Tomsk, 634055
Russian Federation
AU: Arshinov, M
EM: michael@iao.tsc.ru
AF: Institute of Atmospheric Optics, SB RAS, Akademicheskii av.1, Tomsk, 634055
Russian Federation
AU: Saigusa, N
EM: n.saigusa@aist.go.jp
AF: National Institute of Advanced Industrial Science and Technology, 16-1 Onogawa, Tsukuba, 305-8569
Japan
AU: Fujinuma, Y
EM: fujinuma@nies.go.jp
AF: National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, 305-8506
Japan
AU: Inoue, G
EM: inouegen@nies.go.jp
AF: National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, 305-8506
Japan
AB:
We investigated that how the variance method can be used to estimate CO2 flux from aircraft data. The accuracy of the
relatively simple variance method was estimated by comparison with the conventionally used eddy covariance method based on
tower measurement data. The tower data were collected in a Japanese Larch forest and in a very flat Siberian forest during
the summer. CO2 flux by variance method corresponded well with the eddy covariance flux within 30% when ζ less than
-0.04. The CO2 flux was measured by variance method with small aircraft over the forest by means of a closed-path CO2
analyzer (Li6262; Li-COR, USA) and very thin thermocouple (T-type with 0.025mm diameter). The advantage of this system is
very easy installation without any modification to the aircraft body. According to the tower data analysis, this system can
be measured enough frequency response to estimate CO2 flux over the forest by aircraft. Under fine weather conditions, the
aircraft CO2 fluxes estimated by variance method were sometimes in close agreement with the tower CO2 fluxes estimated by
eddy covariance and CBL budget methods. These results suggest that the variance method could offer a portable and valid way
to measure spatial distribution of local surface CO2 flux and regional scale flux.
DE: 0315 Biosphere/atmosphere interactions (0426, 1610)
DE: 0426 Biosphere/atmosphere interactions (0315)
DE: 0428 Carbon cycling (4806)
SC: Biogeosciences [B]
MN: Fall Meeting 2005