HR: 13:40h
AN: V23B-01 INVITED [Abstracts]
TI: Vanadium K-Edge XANES and its Application to Microscale Oxygen Barometry
AU: * Sutton, S R
EM: sutton@cars.uchicago.edu
AF: Department of Geophysical Sciences, University of Chicago, Chicago, IL 60637
United States
AU: * Sutton, S R
EM: sutton@cars.uchicago.edu
AF: Consortium for Advanced Radiation Sources, University of Chicago, Chicago, IL 60637
AU: Karner, J M
EM: jkarner@unm.edu
AF: Institute of Meteoritics, Department of Earth and Planetary Sciences, University of New Mexico,
Albuquerque, NM 87131
United States
AU: Papike, J J
EM: jpapike@unm.edu
AF: Institute of Meteoritics, Department of Earth and Planetary Sciences, University of New Mexico,
Albuquerque, NM 87131
United States
AU: Delaney, J S
EM: jsd@rci.rutgers.edu
AF: Geology Department, Rutgers University, New Brunswick, NJ 08903
United States
AU: Shearer, C K
EM: cshearer@unm.edu
AF: Institute of Meteoritics, Department of Earth and Planetary Sciences, University of New Mexico,
Albuquerque, NM 87131
United States
AU: Newville, M G
EM: newville@cars.uchicago.edu
AF: Consortium for Advanced Radiation Sources, University of Chicago, Chicago, IL 60637
AB:
A promising proxy for oxygen fugacity is the valence of vanadium because it has a large number of possible states (2+, 3+, 4+
and 5+) and is ubiquitous in earth and planetary materials. A non-destructive method for valence determinations of vanadium
and oxygen fugacity estimates with spatial resolution of a few micrometers is synchrotron x-ray absorption near edge
structure (XANES) spectroscopy. The valence determination is based on the intensity of a pre-edge peak near 5470 eV in the
vanadium K-edge XANES spectrum and much of our development work has focused on igneous glasses. A key to this method is
calibration with standards of known valence and experimental charges produced under known conditions. Vanadium pre-edge peak
intensity correlates well with the known valence states for glasses whose valence was established independently. Using this
calibration curve, the effective valences of other glasses can be determined. Measurements on isobaric experimental
couples were used to determine the magnitude of valence variations due to temperature differences. In this way, a
calibration curve for peak intensity versus oxygen fugacity can be produced for the appropriate liquidus temperature of each
unknown glass. The method has been successfully applied to natural glasses from the Earth, Moon and Mars.
DE: 1094 Instruments and techniques
DE: 3640 Igneous petrology
DE: 5480 Volcanism (6063, 8148, 8450)
DE: 8439 Physics and chemistry of magma bodies
SC: Volcanology, Geochemistry, Petrology [V]
MN: Fall Meeting 2005