HR: 0800h
AN: V41E-1512 [Abstracts]
TI: Constraints on Thermochemical Mantle Convection From Plume Excess Temperature, Plume Heat Flux and
Upper Mantle Temperature
AU: * Zhong, S
EM: szhong@anquetil.colorado.edu
AF: University of Colorado at Boulder, Dept. of Physics, University of Colorado at Boulder, Boulder, CO
80309
United States
AB:
Mantle convection is responsible for releasing about 36 TW heat from the mantle. However, how much of the 36 TW mantle heat
flux is from the core (i.e., Qcmb), mantle radiogenic heating and mantle secular cooling remains poorly understood. This
question is further complicated if the mantle is compositionally heterogeneous or layered as suggested by seismic and
geochemical observations. The current study seeks to constrain Qcmb and mantle contributions to the total mantle heat
flux for whole-mantle mantle and layered mantle models by using observations of plume excess temperature, plume heat flux,
and upper mantle temperature. 3-D spherical models of whole-mantle and layered mantle convection are computed for different
Rayleigh number, internal heat generation, buoyancy number,
and bottom layer thickness for layered mantle models. The model results show that these observations are controlled by
internal heating rate in the layer overlying the thermal boundary layer from which mantle plumes are originated. To reproduce
the observations, internal heating rate needs ~65% for whole-mantle convection, but for layered mantle models, the
internal heating rate for the top layer is ~60% for averaged bottom layer thickness ~600 km. A direct inference
from these results is that Qcmb is ~12.6 TW for whole-mantle convection, while for
layered mantle, an upper bound on Qcmb is ~14.4 TW. The required mantle contributions pose constraints on radiogenic
heating rate and secular cooling rate. For whole-mantle convection, the required 23.4 TW from the mantle is consistent with
mantle radiogenic heating from the
Bulk Silicate Earth (BSE) model (i.e., ~13 TW) and heating from mantle secular cooling of 80 K/By (i.e., ~10 TW).
For layered mantle models, if the cooling rate is 80 K/By, the top layer is required to have radiogenic heating rate of
~2.8x10-12 W/kg that is >3 times of that for the depleted MORB sources. If mantle radiogenic heating rate of the
BSE model is taken as the upper bound for the MORB source, then the thickness of the bottom layer is constrained to be <350
km. Our calculations also show: 1) plume temperature in the upper mantle is ~0.55 of the CMB temperature and is mainly
controlled by the
CMB temperature and for whole-mantle convection, and is ~0.65 of the temperature at the density interface for layered
mantle models, 2) plume heat flux accounts for ~75% of Qcmb right above the CMB for whole-mantle convection, but
it decreases by a factor of ~3 when plumes reach
the upper mantle due to adiabatic and diffusive cooling and slight subadiabatic temperature (~180 K).
DE: 8120 Dynamics of lithosphere and mantle: general (1213)
DE: 8121 Dynamics: convection currents, and mantle plumes
DE: 8124 Earth's interior: composition and state (1212, 7207, 7208, 8105)
DE: 8130 Heat generation and transport
SC: Volcanology, Geochemistry, Petrology [V]
MN: Fall Meeting 2005