HR: 0800h
AN: H11F-0380 [Abstracts]
TI: Monitoring Sediment Transport, Stream Stage, and Salinity with Time Domain Reflectometry
AU: * Tidwell, V C
EM: vctidwe@sandia.gov
AF: Sandia National Laboratories, P.O. Box 5800
M.S. 0735
, Albuquerque, NM 87185
AU: Brainard, J R
EM: jrbrain@sandia.gov
AF: Sandia National Laboratories, P.O. Box 5800
M.S. 0735
, Albuquerque, NM 87185
AB:
Results are presented from an ongoing field investigation into the applicability of Time Domain Reflectometry (TDR) for
remote, real-time monitoring of streambed dynamics, stream discharge, and water quality. A TDR based stream monitoring
system involves propagation of a high frequency, low voltage electromagnetic pulse through waveguides installed riverbed
sediments. Reflected signals (traces) from each sensor are analyzed to locate dielectric discontinuities resulting from
air-water and water-sediment interfaces, as well as to evaluate the extent of signal attenuation due to the electrical
conductivity of the media/water. Trace analysis is by way of a multi-section physical based model using the S11 scatter
function and the Cole-Cole parameters for dielectric dispersion and loss (e.g., Feng et al., WRR 35(8), 1999). Application
of this approach to data from laboratory experiments demonstrates that TDR can locate air-water and water-sediment interfaces
to an accuracy of ñ1.9 mm at a precision of ñ0.4mm. Electrical conductivity of freestanding water above a sediment water
interface is measured to ñ8 percent of the actual conductivity at a precision of ñ9 æS/cm.
Eight sensors have been installed in the Rio Grande at Albuquerque, New Mexico. Seven sensors capture riverbed dynamics
while the eighth is installed adjacent to the riverbank to measure river stage. TDR measurements are compared to independent
measures of stream stage, riverbed morphology, and water conductivity. A second monitoring site was established on the
Paria River near Lees Ferry on the Colorado in northern Arizona where TDR measured stream stage and conductivity are
collected. Stream stage data is compared with a float gauge and radar data. Results show that TDR accurately reproduces the
independent measures of stream stage and conductivity.
DE: 1894 Instruments and techniques
DE: 1815 Erosion and sedimentation
DE: 1860 Runoff and streamflow
SC: Hydrology [H]
MN: 2004 AGU Fall Meeting