HR: 0800h
AN: H21E-1049 [Abstracts]
TI: Direct-Push Cross-Hole Slug Tests: A New Tool for Hydraulic Characterization of Aquifers
AU: * Brauchler, R
EM: ralf.brauchler@uni-tuebingen.de
AF: Kansas Geological Survey, 1930 Constant Ave., Campus West
University of Kansas, Lawrence, KS 66047
United States
AU: Butler, J J
EM: jbutler@kgs.ku.edu
AF: Kansas Geological Survey, 1930 Constant Ave., Campus West
University of Kansas, Lawrence, KS 66047
United States
AU: Aufman, M S
EM: msaufman@olemiss.edu
AF: Kansas Geological Survey, 1930 Constant Ave., Campus West
University of Kansas, Lawrence, KS 66047
United States
AU: McKay, S E
EM: mckays@unr.nevada.edu
AF: Kansas Geological Survey, 1930 Constant Ave., Campus West
University of Kansas, Lawrence, KS 66047
United States
AU: McCall, W
EM: mccallw@geoprobe.com
AF: Geoprobe Systems, 601 N. Broadway, Salina, KS 67401
United States
AU: Knobbe, S
EM: knobbes@geoprobe.com
AF: Geoprobe Systems, 601 N. Broadway, Salina, KS 67401
United States
AU: Healey, J M
EM: john_healey@kgs.ku.edu
AF: Kansas Geological Survey, 1930 Constant Ave., Campus West
University of Kansas, Lawrence, KS 66047
United States
AB:
Slug tests have traditionally been utilized as a means to determine the hydraulic conductivity (K) of an aquifer at a
relatively small scale. When performed in a cross-hole mode, however, slug tests can be used to gain considerably more
information. Despite the common perception that a slug test only affects a small volume of the aquifer in the vicinity of the
test well, response data with a reasonable signal to noise ratio can be collected at distances of over several hundred times
the radius of the screen of the test well. Analysis of such data can yield estimates of specific storage and the horizontal
and vertical components of K, as well as providing insight into aquifer heterogeneity. Although cross-hole slug tests have
been used in some previous studies, the utility of the approach has been limited by the need for relatively closely spaced
wells. That limitation, however, can be readily overcome in unconsolidated formations by exploiting the access to the shallow
subsurface provided by direct-push (DP) technology. DP technology can be used to install observation points at positions
most advantageous for a particular study and then to reposition points between tests. The potential of DP cross-hole slug
tests was investigated in a well-characterized sand and gravel aquifer underlying the Kansas River floodplain. An extensive
series of slug tests were performed to assess the dependence of test data on the radius and screen length of the test well,
and the lateral and vertical position of the observation interval. Using a 0.05-m test well, response data with a reasonable
signal to noise ratio were obtained at observation intervals separated from the test well by over 11 m laterally and up to 3
m vertically. The results of these tests indicate that DP cross-hole slug tests could be a valuable tool for a variety of
applications ranging from estimation of bulk aquifer properties to monitoring of temporal changes in the hydraulic properties
of permeable reactive barriers. This approach is particularly well-suited for providing information about anisotropy in
hydraulic conductivity, a quantity that is rarely known but often of considerable practical importance, especially for the
design of remediation systems.
DE: 5114 Permeability and porosity
DE: 1829 Groundwater hydrology
DE: 1894 Instruments and techniques
SC: Hydrology [H]
MN: 2004 AGU Fall Meeting