HR: 14:50h
AN: H43I-05 [Abstracts]
TI: Temperature-Profile Methods for Estimating Thermally-Driven Flow Processes in Superheated
Rocks
AU: * Birkholzer, J T
EM: jtbirkholzer@lbl.gov
AF: Ernest Orlando Lawrence Berkeley National Laboratory, Earth Sciences Division, 1 Cyclotron Road, MS
90-1116, Berkeley, CA 94720
United States
AB:
In geologic repositories for storage of nuclear wastes, the heat generated by the decay of the radioactive waste may result
in rock temperatures high enough to cause boiling conditions in the subsurface, which gives rise to strongly altered flow
processes. These flow processes are characterized by (1) vapor production in the superheated zone close to the heat source,
(2) pressure-driven vapor transport away from the heat source, (3) condensation in cooler regions, and (4) reflux of the
condensate back to the heat source. Since the magnitude of such flow perturbation is extremely hard to measure in the field,
we propose a simple temperature-profile method that uses high-resolution temperature data for deriving such information. The
energy that is transmitted by the vapor-water reflux processes creates a nearly isothermal zone maintained at about the
boiling temperature, referred to as a heat-pipe signature. Characteristic features of the temperature profile, such as the
differences in the gradients inside and outside of this zone, can be used to derive the approximate magnitude of the vapor
and water fluxes, for both steady-state and transient conditions. We present the theoretical basis for the proposed
temperature-profile method, test the method in comparison with a semi-analytical solution of thermally-driven flow processes,
and present a sample application using measured temperature profiles from an underground heater test.
DE: 5104 Fracture and flow
DE: 1875 Unsaturated zone
DE: 1878 Water/energy interactions
SC: Hydrology [H]
MN: 2004 AGU Fall Meeting