HR: 1340h
AN: T43B-1322 [Abstracts]
TI: Interpretation of Heat Flow and Seismic Data from Yellowstone Lake, Yellowstone National Park
AU: * Negraru, P T
EM: pnegraru@smu.edu
AF: Southern Methodist University, Geological Sciences
3225 Daniel, Heroy, Rm. 210, Dallas, TX 75275
United States
AU: Blackwell, D D
EM: blackwel@smu.edu
AF: Southern Methodist University, Geological Sciences
3225 Daniel, Heroy, Rm. 210, Dallas, TX 75275
United States
AB:
The heat flow map of Yellowstone Lake shows a complex thermal regime with variations of more than two orders of magnitude.
The major geothermal systems mapped are within the caldera boundary, in the northern part of the lake and in West Thumb. In
the northern part of the lake two areas of extremely high heat flow are identified: an area east of Stevenson Island (heat
flow more than 10000 mW/m$^{2}$), not previously known to have high heat flow and Mary Bay-Sedge Bay geothermal system (up to
40000 mW/m$^{2}$). These are separated by an area with background heat flow of 1500 to 2000 mW/m$^{2}$ which correlates with
large sediment thickness. Therefore the whole area from east of Stevenson Island to the Mary Bay is interpreted as a single
geothermal system variably attenuated by the conductive effects of the sediments. Seismic data show that the western boundary
of this high heat area is the complex graben which extends from the Lake Hotel in an approximately north-south direction
east of Stevenson Island. We present evidence (heat flow, seismic and geologic features observed from underwater video) that
the Hotel Fault, one of the graben faults, extends on the east side of the Stevenson's Island, not on the west. West of the
graben the heat flow could be as low as 150 mW/m$^{2}$. Although several topographic notches similar to the hydrothermal
vents east of Stevenson Island were identified west of the graben structure, the nearby heat flow values are low, suggesting
the presence of cold, not hot springs. The decrease of the gradients to the south is more gradual and is not associated with
major faulting or with the caldera boundary. The other important geothermal system is West Thumb, but no extremely high heat
flow values were found.
The areas east of Stevenson Island and Mary Bay - Sedge Bay are identified as potential geothermal hazards. However, in Mary
Bay, at the hottest point located in the lake, the boiling point temperatures are reached at more than 5 m below the bottom
of the lake, in a water depth of 40 m. If a geothermal explosion were to occur it would require a sudden drop of water level
with at least 6 m. By connecting several discontinuous features it has been argued that the maximum possible length of the
Hotel Fault, the largest fault in the lake, is 25 km. However, the fault was mapped only north of Stevenson Island (for about
3 km). In the south it could be masked by deformed area in the east of Stevenson Island (up to 8 km). No link to the Eagle
Bay fault to the south was observed in sparker records and thus the maximum fault length is only 12 km. We argue that a fault
12 km long could not offset the bottom of the lake by 6 m. The overall low stress condition in the caldera (weak crust)
support the presence of a high number of small events rather than large single fault events.
DE: 8110 Continental tectonics--general (0905)
SC: Tectonophysics [T]
MN: 2004 AGU Fall Meeting