AB:
The call for age measurements with less than 1 per mil error puts a demand upon geochronologists to be aware of and quantify
a number of problems which were previously negligible. One such factor is $^{39}$Ar recoil loss during sample irradiation, a
phenomenon which is widely assumed to affect only unusually small crystals having exceptionally high surface/volume ratios.
This phenomenon has important implications for thermochronologic studies seeking to exploit a range of closure temperatures
arising from variable diffusion radii. Our study focuses on biotite, in which spatial isotope distributions cannot be
reliably recovered by stepwise heating and which therefore lack recoil-diagnostic age spectrum behavior.
Previous work by Renne {\it et al}. [Application of a deuteron-deuteron (D-D) neutron generator to $^{40}$Ar/$^{39}$Ar
geochronology, {\it Applied Radiation and Isotopes}, in press] used the SRIM code to calculate a $\sim$20% $^{39}$Ar recoil
loss from the outermost 0.25 $\mu$m of an infinite slab of phyllosillicate. This result is applied to measured grains of the
biotite standard GA1550, a hypabyssal granite from the Mount Dromedary Complex, Australia. We measure the thickness and
surface area of 166 grains and approximate the shape of each grain as a cylinder. Grain thickness ranges from 3 to 210
$\mu$m, with an average grain radius of 350 $\mu$m. We predict the amount of $^{39}$Ar recoil loss from each grain, finding
an expected age error $>$0.1 % for grains thinner than 150 $\mu$m, a $>$1% error for grain less than 10 $\mu$m thick, and
up to a 3% error for grains less than 3 $\mu$m thick. These modeling results will be tested by analysis of the measured
grains after irradiation in the Oregon State University TRIGA reactor.
It is important to either account for $^{39}$Ar loss in thin biotite grains, or use sufficiently thick ones so that recoil
loss is negligible. Our results indicate that only biotite grains thicker than 150 $\mu$m should be used for neutron fluence
monitoring in order to avoid bias greater than the limit of analytical resolution ($\sim$0.1%). We will focus our
discussion on: (1) evaluating the accuracy of the recoil model and (2) application of the results to thermochronology.
DE: 1035 Geochronology
SC: Volcanology, Geochemistry, Petrology [V]